# Boeing Alert Requirements Bulletin 747-28A2373 RB: No revision named

- Rights: © The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2026-7215; AD 2026-22-04 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Boeing Alert Requirements Bulletin 747-28A2373 RB](https://openairdocs.org/service-documents/boeing/747-28a2373-rb.md)
- Title as filed: RB-747-28A2373-00
- Pages: 29
- PDF: https://openairdocs.org/files/sha256/48/1c/481c068a5648670cc299182f9af060423fab796e6a2557185b9c57755b903e96
- Page: https://openairdocs.org/service-documents/boeing/747-28a2373-rb/file/481c068a5648

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

Commercial 
Airplanes
747
Requirements Bulletin
ALERT
Number: 747-28A2373 RB
Original Issue: November 06, 2025
ATA System: 2817
SUBJECT: FUEL - Horizontal Stabilizer Tank Fuel Transfer System - Transfer Pump Housing Inlet
Check Valve and Transfer Pump Motor Impeller Inlet Adapter Inspection and
Replacement
EXPORT CONTROLLED - This technology or software is subject to the U.S. Export Administration Regulations
(EAR), (15 C.F.R. Parts 730-774). No authorization from the U.S. Department of Commerce is required for
export, re-export, in-country transfer, or access EXCEPT to country group E:1 or E:2 countries/persons per
Supp.1 to Part 740 of the EAR.
9E991ECCN:
Copyright © 2025 The Boeing Company
Treatment of this document and its content is governed by contract with Boeing. Rights to use this document
are licensed on a per aircraft basis and such rights may not be transferable. For more information, contact The
Boeing Company.
Boeing, the Boeing signature, the Boeing symbol, 707, 717, 727, 737, 747, 757, 767, 777, 787, Dreamliner,
BBJ, DC-8, DC-9, DC-10, KC-10, KC-46, KDC-10, MD-10, MD-11, MD-80, MD-88, MD-90, P-8, Poseidon and
Boeing liveries are all trademarks owned by The Boeing Company; and no trademark license is granted in
connection with this document unless provided in writing by Boeing.
Original Issue: November 06, 2025
747-28A2373 RB
1 of 29
4.0

### Page 2

Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
2 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT
BLANK PAGE

### Page 3

Table of Contents
1. EFFECTIVITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
A. Airplanes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
B. Spares Affected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2. CONCURRENT REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3. COMPLIANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4. APPROVAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5. ACCOMPLISHMENT INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
A. General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
B. Work Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
FIGURE 1: HORIZONTAL STABILIZER FUEL TANK - LEFT TRANSFER PUMP HOUSING - INLET CHECK
VALVE (ICV) INSPECTION [Group 1, Configuration 1] . . . . . . . . . . . . . . . . . . . 19
FIGURE 2: HORIZONTAL STABILIZER FUEL TANK - RIGHT TRANSFER PUMP HOUSING - INLET
CHECK VALVE (ICV) INSPECTION [Group 1, Configuration 1] . . . . . . . . . . . . . . . 23
FIGURE 7: HORIZONTAL STABILIZER FUEL TANK - TRANSFER PUMP - MOTOR IMPELLER INLET
ADAPTER (IA) INSPECTION [Group 1, Configuration 1] . . . . . . . . . . . . . . . . . . 27
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
3 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 4

Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
4 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT
BLANK PAGE

### Page 5

Commercial 
Airplanes
747
Requirements Bulletin
ALERT
Number: 747-28A2373 RB
Original Issue: November 06, 2025
ATA System: 2817
SUBJECT: FUEL - Horizontal Stabilizer Tank Fuel Transfer System - Transfer Pump Housing Inlet
Check Valve and Transfer Pump Motor Impeller Inlet Adapter Inspection and
Replacement
THIS DOCUMENT IS SENT TO THE OPERATORS OF RECORD OF THE AIRPLANES SHOWN IN
EFFECTIVITY. IF AN AIRPLANE HAS BEEN LEASED OR SOLD, SEND THIS DOCUMENT TO THE NEW
OPERATOR. IF APPLICABLE SPARES HAVE BEEN SOLD, SEND THIS DOCUMENT TO THE NEW OWNER.
THIS IS AN ENHANCED REQUIRED FOR COMPLIANCE DOCUMENT. THE BOEING PROCESSES USED
TO CREATE THE SERVICE BULLETIN (SB) AND THE REQUIREMENTS BULLETIN (RB) ENSURE THAT
THE INFORMATION BETWEEN "RC START" AND "RC END" IN THE SB ARE IDENTICAL TO THE
INFORMATION IN THE SAME SECTIONS (COMPLIANCE, WORK INSTRUCTIONS…) OF THE RB WHICH
THE SB REFERS TO AS THE RELATED DOCUMENT.
1. Effectivity
A. Airplanes
This bulletin is applicable to 747-8, 747-400 Airplane(s), line number(s) 696, 700, 705, 708, 715,
717, 721-723, 725-749, 751, 753-771, 773-775, 777-809, 811-813, 815-817, 819-821, 823-843,
845-877, 880-885, 887-890, 892-906, 908-913, 915-919, 921-926, 928-934, 936-940, 942-947,
949-951, 953-962, 964-967, 969-971, 973-974, 976-977, 979-990, 992-995, 997-1001, 1003-1007,
1009-1019, 1021-1035, 1037-1041, 1043, 1045-1051, 1053-1059, 1061-1063, 1067-1068,
1070-1086, 1088-1093, 1095, 1097-1104, 1106-1122, 1124, 1126-1138, 1140-1162, 1164,
1166-1168, 1170-1172, 1174-1178, 1180-1183, 1185-1188, 1190-1191, 1193-1202, 1204-1209,
1211-1212, 1214-1216, 1218-1219, 1221, 1223, 1225-1226, 1228-1230, 1232-1234, 1236-1237,
1239, 1241, 1243, 1245, 1247, 1250, 1253, 1258, 1261-1262, 1264-1266, 1268, 1270, 1272-1278,
1280, 1284, 1287, 1289-1290, 1292-1293, 1296-1297, 1299, 1301-1303, 1308, 1313, 1320-1321,
1324-1325, 1327, 1330-1331, 1335-1337, 1343, 1353-1354, 1357-1358, 1434-1435, 1439-1440,
1443, 1446, 1449, 1451, 1453, 1456, 1459, 1466, 1468, 1470, 1472, 1475, 1477, 1480, 1492,
1494-1495, 1497-1500, 1503, 1506-1515, 1517-1518, 1524-1525, 1527, 1529, 1531, 1537-1539
in 1 Group(s). Where the effectivity is presented with hyphens between line numbers, the airplane
applicability means "through" and "inclusive", e.g. line numbers 1-9 means line numbers 1 through
9 inclusive.
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
5 of 29

### Page 6

NOTE: A horizontal stabilizer tank is considered to be "activated" if it has not been deactivated
in production or deactivated by an approved alteration.
DESCRIPTIONCONFIGURATIONGROUP
747-400 and 747-8 airplanes.-1
747-400 and 747-8 airplanes equipped with activated Horizontal
Stabilizer Fuel Tank with Crane Aerospace Hydro-Aire horizontal
stabilizer fuel Transfer Pump Housings and Transfer Pump Motor
Impellers.
1
747-400 and 747-8 airplanes not equipped with activated Horizontal
Stabilizer Fuel Tank with Crane Aerospace Hydro-Aire horizontal
stabilizer fuel Transfer Pump Housings and Transfer Pump Motor
Impellers.
2
Airplane Models:
747-400, 747-8
GroupVariable Number
1RC001 - RC009
1RC021 - RC040
1RC051 - RC060
1RC066 - RC072
1RF001 - RF006
1RM001 - RM007
1RM010 - RM013
1RM021 - RM024
1RM026 - RM030
1RM036 - RM045
1RM051 - RM053
1RM071
1RM081 - RM084
1RM091
1RM096 - RM097
1RM116 - RM117
1RM126 - RM132
1RM136 - RM147
GroupVariable Number
1RM156 - RM158
1RM166 - RM177
1RM191 - RM192
1RM231 - RM233
1RM241 - RM246
1RM261 - RM264
1RM316 - RM318
1RM331 - RM333
1RM341
1RM351 - RM355
1RM366 - RM367
1RM401 - RM403
1RM426
1RM431
1RM441 - RM443
1RM445
1RM801 - RM803
1RM811 - RM813
GroupVariable Number
1RT001 - RT014
1RT021 - RT022
1RT031 - RT035
1RT041 - RT047
1RT061
1RT071 - RT075
1RT101 - RT103
1RT121
1RT131 - RT137
1RT151 - RT152
1RT161 - RT168
1RT401 - RT412
1RT431 - RT447
1RT451 - RT469
1RT471 - RT499
1RT501 - RT535
1RT551 - RT568
1RT571 - RT591
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
6 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 7

GroupVariable Number
1RT601 - RT657
1RT671 - RT673
1RT681 - RT682
1RT691 - RT699
1RT701 - RT704
1RT711 - RT717
1RT741 - RT757
1RT776 - RT777
1RT781 - RT784
GroupVariable Number
1RT801 - RT803
1RT811 - RT814
1RT831 - RT837
1RT861 - RT864
1RT876 - RT880
1RT931 - RT932
1RT945 - RT949
1RT951 - RT955
1RT966 - RT967
GroupVariable Number
1RU001 - RU006
1RU016 - RU017
1RU031 - RU032
1RU051 - RU052
1RU059 - RU062
1RU081 - RU083
1RU101 - RU102
1RU121 - RU132
1RU809
B. Spares Affected
None.
2. CONCURRENT REQUIREMENTS
None.
3. COMPLIANCE
The Federal Aviation Administration (FAA) will possibly release an Airworthiness Directive related to
Requirements Bulletin 747-28A2373 RB. The Airworthiness Directive will make the compliance tasks and
times given in Requirements Bulletin 747-28A2373 RB mandatory.
Accomplish the required action(s), based on the applicable condition(s) in Table 1 and Table 2, in accordance
with Accomplishment Instructions.
When more than one OPTION is given for a CONDITION, do only one of the OPTION numbers. When
more than one ACTION is given for a CONDITION or an OPTION, do all of the ACTION numbers for that
CONDITION or OPTION.
Group 1, Configuration 2:
No action required.
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
7 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 8

Group 1, Configuration 1:
Table 1: Left Transfer Pump Housing Inlet Check Valve (ICV) and Transfer Pump Motor Impeller Inlet
Adapter (IA) Detailed Inspection
Repeat Interval
(Not to Exceed)
Boeing Recommended
Compliance Time
ActionCondition
-Within 20,000 flight hours
after the Original Issue
date of Requirements
Bulletin 747-28A2373
RB.
ACTION 1: Do a Detailed
Inspection (DET) of the
left Transfer Pump Hous-
ing Inlet Check Valve
(ICV) for any damage. (a)
All Airplanes.
-Whichever occurs first;ACTION 2: Do a DET of
the left Transfer Pump
Motor Impeller Inlet
Adapter (IA) for any dam-
age. (c)
1. Within 5,000 flight
hours after the Original
Issue date of Require-
ments Bulletin 747-
28A2373 RB.
2. Within 1 year after the
Original Issue date of
Requirements Bulletin
747-28A2373 RB.
20,000 flight hours.-Repeat the DET of the
left Transfer Pump Hous-
ing ICV for any damage.
(a)
CONDITION 1: NO DAM-
AGE FOUND IN THE LEFT
TRANSFER PUMP
HOUSING ICV.
-Before further flight.OPTION 1 (ACTION 1):
Replace the left Transfer
Pump Housing ICV with
a new or serviceable
Transfer Pump Housing
ICV. (b)
CONDITION 2: ANY DAM-
AGE FOUND IN THE LEFT
TRANSFER PUMP
HOUSING ICV.
20,000 flight hours.-OPTION 1 (ACTION 2):
Repeat the DET of the
left Transfer Pump Hous-
ing ICV for any damage.
(a)
-Before further flight.OPTION 2 (ACTION 1):
Replace the left Transfer
Pump Housing with a
Transfer Pump Housing
containing a new or ser-
viceable transfer pump
housing ICV. (b)
20,000 flight hours.-OPTION 2 (ACTION 2):
Repeat the DET of the
left Transfer Pump Hous-
ing ICV for any damage.
(a)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
8 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 9

Group 1, Configuration 1:
Table 1: Left Transfer Pump Housing Inlet Check Valve (ICV) and Transfer Pump Motor Impeller Inlet
Adapter (IA) Detailed Inspection
Repeat Interval
(Not to Exceed)
Boeing Recommended
Compliance Time
ActionCondition
20,000 flight hours.-Repeat the DET of the
left Transfer Pump Motor
Impeller IA for any dam-
age. (c)
CONDITION 3: NO DAM-
AGE FOUND IN THE LEFT
TRANSFER PUMP MO-
TOR IMPELLER IA.
-Before further flight.CONDITION 4 (ACTION
1): Replace the left
Transfer Pump Motor Im-
peller with a new or ser-
viceable Transfer Pump
Motor Impeller. (d)
CONDITION 4: ANY DAM-
AGE FOUND IN THE LEFT
TRANSFER PUMP MO-
TOR IMPELLER IA.
20,000 flight hours.-CONDITION 4 (ACTION
2): Repeat the DET of the
left Transfer Pump Motor
Impeller IA for any dam-
age. (c)
(a) Damage is defined as an ICV for which the hinge pin protrudes past the flapper arm on only one
side or there is any metal disk gouging, missing material, corrosion, burrs or raised material
found.
(b) A serviceable Transfer Pump Housing ICV is an ICV for which the hinge pin protrudes past the
flapper arm on both sides and there is no metal disk gouging, missing material, corrosion, burrs,
or raised material.
(c) Damage is defined as a transfer pump motor impeller IA where the Stellite 6 thermal spray
coating is scratched or worn to base metal or there is deformation or wear on the inner diameter
or outer rim from contact with the inlet check valve.
(d) A serviceable Transfer Pump Motor Impeller is a transfer pump motor impeller that has a transfer
pump motor impeller IA where the Stellite 6 thermal spray coating is not scratched or worn to
base metal, and there is no deformation or wear on the inner diameter or outer rim from contact
with the inlet check valve.
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
9 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 10

Group 1, Configuration 1:
Table 2: Right Transfer Pump Housing Inlet Check Valve (ICV) and Transfer Pump Motor Impeller
Inlet Adapter (IA) Detailed Inspection
Repeat Interval
(Not to Exceed)
Boeing Recommended
Compliance Time
ActionCondition
-Within 20,000 flight hours
after the Original Issue
date of Requirements
Bulletin 747-28A2373
RB.
ACTION 1: Do a Detailed
Inspection (DET) of the
right Transfer Pump
Housing Inlet Check
Valve (ICV) for any dam-
age. (a)
All Airplanes.
-Whichever occurs first;ACTION 2: Do a DET of
the right Transfer Pump
Motor Impeller Inlet
Adapter (IA) for any dam-
age. (c)
1. Within 5,000 flight
hours after the Original
Issue date of Require-
ments Bulletin 747-
28A2373 RB.
2. Within 1 year after the
Original Issue date of
Requirements Bulletin
747-28A2373 RB.
20,000 flight hours.-Repeat the DET of the
right Transfer Pump
Housing ICV for any
damage. (a)
CONDITION 5: NO DAM-
AGE FOUND IN THE
RIGHT TRANSFER PUMP
HOUSING ICV.
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
10 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 11

Group 1, Configuration 1:
Table 2: Right Transfer Pump Housing Inlet Check Valve (ICV) and Transfer Pump Motor Impeller
Inlet Adapter (IA) Detailed Inspection
Repeat Interval
(Not to Exceed)
Boeing Recommended
Compliance Time
ActionCondition
-Before further flight.OPTION 1 (ACTION 1):
Replace the right Trans-
fer Pump Housing ICV
with a new or serviceable
Transfer Pump Housing
ICV. (b)
CONDITION 6: ANY DAM-
AGE FOUND IN THE
RIGHT TRANSFER PUMP
HOUSING ICV.
20,000 flight hours.-OPTION 1 (ACTION 2):
Repeat the DET of the
right Transfer Pump
Housing ICV for any
damage. (a)
-Before further flight.OPTION 2 (ACTION 1):
Replace the right Trans-
fer Pump Housing with a
Transfer Pump Housing
containing a new or ser-
viceable transfer pump
housing ICV. (b)
20,000 flight hours.-OPTION 2 (ACTION 2):
Repeat the DET of the
right Transfer Pump
Housing ICV for any
damage. (a)
20,000 flight hours.-Repeat the DET of the
right Transfer Pump Mo-
tor Impeller IA for any
damage. (c)
CONDITION 7: NO DAM-
AGE FOUND IN THE
RIGHT TRANSFER PUMP
MOTOR IMPELLER IA.
-Before further flight.CONDITION 8 (ACTION
1): Replace the right
Transfer Pump Motor Im-
peller with a new or ser-
viceable Transfer Pump
Motor Impeller. (d)
CONDITION 8: ANY DAM-
AGE FOUND IN THE
RIGHT TRANSFER PUMP
MOTOR IMPELLER IA.
20,000 flight hours.-CONDITION 8 (ACTION
2): Repeat the DET of the
right Transfer Pump Mo-
tor Impeller IA for any
damage. (c)
(a) Damage is defined as an ICV for which the hinge pin protrudes past the flapper arm on only one
side or there is any metal disk gouging, missing material, corrosion, burrs or raised material
found.
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
11 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 12

Group 1, Configuration 1:
Table 2: Right Transfer Pump Housing Inlet Check Valve (ICV) and Transfer Pump Motor Impeller
Inlet Adapter (IA) Detailed Inspection
Repeat Interval
(Not to Exceed)
Boeing Recommended
Compliance Time
ActionCondition
(b) A serviceable Transfer Pump Housing ICV is an ICV for which the hinge pin protrudes past the
flapper arm on both sides and there is no metal disk gouging, missing material, corrosion, burrs,
or raised material.
(c) Damage is defined as a transfer pump motor impeller IA where the Stellite 6 thermal spray
coating is scratched or worn to base metal or there is deformation or wear on the inner diameter
or outer rim from contact with the inlet check valve.
(d) A serviceable Transfer Pump Motor Impeller is a transfer pump motor impeller that has a transfer
pump motor impeller IA where the Stellite 6 thermal spray coating is not scratched or worn to
base metal, and there is no deformation or wear on the inner diameter or outer rim from contact
with the inlet check valve.
4. APPROVAL
This Requirements Bulletin was examined by the Federal Aviation Administration (FAA). The changes
specified in this document comply with the applicable regulations and are FAA approved, as well as European
Union Aviation Safety Agency (EASA) approved for all EASA approved airplanes listed in this Requirements
Bulletin effectivity. This document and its approval were based on the airplane in its original Boeing delivery
configuration or as modified by other Boeing changes.
If an airplane has a non-Boeing modification or repair that affects a component or system also affected by
this Requirements Bulletin, the operator is responsible for obtaining appropriate regulatory agency approval
before incorporating this Requirements Bulletin.
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
12 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 13

5.    ACCOMPLISHMENT INSTRUCTIONS
A. GENERAL INFORMATION
OBEY THE MANUFACTURER'S PROCEDURES WHEN YOU DO TASKS THAT
ARE RELATED TO AIRWORTHINESS LIMITATIONS (AWL). IF YOU DO NOT
OBEY THE PROCEDURES, IT CAN INCREASE THE RISK OF A SOURCE OF
IGNITION. INJURIES TO PERSONNEL, AND DAMAGE TO EQUIPMENT CAN
OCCUR IF THERE IS A FIRE OR EXPLOSION.
WARNING
KEEP THE WORK AREA, WIRES AND ELECTRICAL BUNDLES CLEAN OF
METAL PARTICLES OR CONTAMINATION WHEN YOU USE TOOLS. UNWANTED
MATERIAL, METAL PARTICLES OR CONTAMINATION CAUGHT IN WIRE
BUNDLES CAN CAUSE DAMAGE TO THE BUNDLES. DAMAGED WIRE BUNDLES
CAN CAUSE SPARKS OR OTHER ELECTRICAL DAMAGE.
CAUTION
NOTE: 1. This is an Enhanced Required for Compliance document. There will be a separate
Service Bulletin (SB) and a separate Requirements Bulletin (RB). If an RB is mandated
by an Airworthiness Directive (AD), then all applicable requirements specified in the
RB must be done. In the RB, the "Refer to the listed procedures..." column of the
table(s) in the Work Instructions is for reference only. The procedures in that column
are not required by the AD and are for guidance only. For the related SB, some
locations are marked RC Start and RC End to identify the requirements that are
restated from the RB. For the related SB, the areas between RC Start and RC End,
including sub-steps and any figures identified between RC Start and RC End, must
be done to comply with the AD. Therefore, an Alternative Method of Compliance
(AMOC) is required for any deviations to steps between RC Start and RC End,
including substeps and identified figures. For the related SB, the steps not between
RC Start and RC End may be deviated from using accepted methods in accordance
with the operator's maintenance or inspection program without obtaining approval
of an AMOC; this is provided that the steps between RC Start and RC End, including
sub-steps and identified figures, can still be done as specified, and the airplane can
be put back in an airworthy condition. Figures not required for compliance are omitted
from the RB.
2. This is an Enhanced Required for Compliance document. The Boeing processes
used to create the Service Bulletin (SB) and the Requirements Bulletin (RB) ensure
that the information between "RC Start" and "RC End" in the SB are identical to the
information in the same sections (Compliance, Work Instructions...) of the RB which
the SB refers to as the related document.
3. The compliance times for the actions in WORK INSTRUCTIONS are in Compliance.
4. Unless shown differently, these dimensions and tolerances are used:
– Linear dimensions are in inches
– Tolerance on linear dimensions, other than rivet and bolt edge margins, is plus
or minus 0.03 inch
– Tolerance on rivet and bolt edge margin is plus or minus 0.05 inch
– Angular tolerance is plus or minus 2 degrees
– Hole dimensions for standard solid rivets and fasteners are in Structural Repair
Manual (SRM) Chapter 51
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
13 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 14

– Torque Values:
— Values for structural fasteners are given in 747 Structural Repair Manual,
Chapter 51.
— Values for airframe maintenance tasks are included in Chapter 20 of 747
Aircraft Maintenance Manual (AMM).
— Values for engine maintenance tasks are included in Chapter 70 of 747
Aircraft Maintenance Manual (AMM).
— Non-standard torque values for maintenance tasks are included in the
applicable installation step.
5. These work instructions refer to procedures included in other Boeing documents.
When the words "refer to" are used and the operator has an accepted alternative
procedure, the accepted alternative procedure can be used. When the words "in
accordance with" are included in the instruction, the procedure in the Boeing document
must be used.
6. Where the work instructions include installation of a kept part, a new or serviceable
part with the same part number can be installed as an alternative to the kept part.
7. If it is necessary to remove more parts for access, you can remove those parts. If
you can get access without removing identified parts, it is not necessary to remove
all of the identified parts. Jacking and shoring limitations must be observed.
8. Use the approved fastener, process and material substitutions in accordance with
SRM Chapter 51.
9. A Detailed Inspection (DET) is defined as: An intensive examination of a specific
item, installation or assembly to detect damage, failure or irregularity. This could
include tactile assessment in which a component or assembly can be checked for
tightness/security. Available lighting is normally supplemented with a direct source
of good lighting at an intensity deemed appropriate. Inspection aids such as mirrors
and magnifying lenses may be necessary. Surface cleaning and elaborate access
procedures may be required.
10. When more than one OPTION is given for a CONDITION, do only one of the OPTION
numbers. When more than one ACTION is given for a CONDITION or an OPTION,
do all of the ACTION numbers for that CONDITION or OPTION.
11. The instructions in Work Instructions and the figures can include operation of tools
or test equipment. Boeing Engineering Tool Drawings, the Illustrated Tool and
Equipment Manual, and the Special Tool and Ground Handling Drawing Index contain
data on versions of the tools or test equipment that you can use. It is permitted to
use replaced tools. It is not permitted to use superseded tools.
12. Use of colors in Figures is based on guidance from the ATA e-Business Program
(ATA) iSpec 2200.
B. WORK INSTRUCTIONS
Actions Required For Compliance
1. Requirements
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
14 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 15

Group 1, Configuration 2:
No action required.
Group 1, Configuration 1:
Table 1: Left Transfer Pump Housing Inlet Check Valve (ICV) and Transfer Pump Motor Impeller Inlet
Adapter (IA) Detailed Inspection
Refer to the listed proce-
dures in SB 747-28A2373
Original Issue or later
approved revisions as an
accepted procedure.
Method Of ComplianceActionCondition
Do PART 1: PREPARA-
TION
-ACTION 1: Do a Detailed
Inspection (DET) of the left
Transfer Pump Housing
Inlet Check Valve (ICV) for
any damage. (a)
All Airplanes.
-FIGURE 1
Do PART 1: PREPARA-
TION
-ACTION 2: Do a DET of
the left Transfer Pump
Motor Impeller Inlet
Adapter (IA) for any dam-
age. (c)
FIGURE 7
Do PART 2: RESTORA-
TION
-Repeat the DET of the left
Transfer Pump Housing
ICV for any damage. (a)
CONDITION 1: NO DAM-
AGE FOUND IN THE
LEFT TRANSFER PUMP
HOUSING ICV. Do PART 1: PREPARA-TION-
-FIGURE 1
FIGURE 3-OPTION 1 (ACTION 1):
Replace the left Transfer
Pump Housing ICV with a
new or serviceable Trans-
fer Pump Housing ICV.(b)
CONDITION 2: ANY
DAMAGE FOUND IN THE
LEFT TRANSFER PUMP
HOUSING ICV.
Do PART 2: RESTORA-
TION
-
Do PART 1: PREPARA-
TION
-OPTION 1 (ACTION 2):
Repeat the DET of the left
Transfer Pump Housing
ICV for any damage. (a) -FIGURE 1
FIGURE 5-OPTION 2 (ACTION 1):
Replace the left Transfer
Pump Housing with a
Transfer Pump Housing
containing a new or ser-
viceable transfer pump
housing ICV. (b)
Do PART 2: RESTORA-
TION
-
Do PART 1: PREPARA-
TION
-OPTION 2 (ACTION 2):
Repeat the DET of the left
Transfer Pump Housing
ICV for any damage. (a) -FIGURE 1
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
15 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 16

Group 1, Configuration 1:
Table 1: Left Transfer Pump Housing Inlet Check Valve (ICV) and Transfer Pump Motor Impeller Inlet
Adapter (IA) Detailed Inspection
Refer to the listed proce-
dures in SB 747-28A2373
Original Issue or later
approved revisions as an
accepted procedure.
Method Of ComplianceActionCondition
Do PART 2: RESTORA-
TION
-Repeat the DET of the left
Transfer Pump Motor Im-
peller IA for any damage.
(c)
CONDITION 3: NO DAM-
AGE FOUND IN THE
LEFT TRANSFER PUMP
MOTOR IMPELLER IA. Do PART 1: PREPARA-TION-
-FIGURE 7
FIGURE 8-CONDITION 4 (ACTION
1): Replace the left Trans-
fer Pump Motor Impeller
with a new or serviceable
Transfer Pump Motor Im-
peller. (d)
CONDITION 4: ANY
DAMAGE FOUND IN THE
LEFT TRANSFER PUMP
MOTOR IMPELLER IA.
Do PART 2: RESTORA-
TION
-
Do PART 1: PREPARA-
TION
-CONDITION 4 (ACTION
2): Repeat the DET of the
left Transfer Pump Motor
Impeller IA for any dam-
age. (c)
-FIGURE 7
(a) Damage is defined as an ICV for which the hinge pin protrudes past the flapper arm on only one side or
there is any metal disk gouging, missing material, corrosion, burrs or raised material found.
(b) A serviceable Transfer Pump Housing ICV is an ICV for which the hinge pin protrudes past the flapper
arm on both sides and there is no metal disk gouging, missing material, corrosion, burrs, or raised mate-
rial.
(c) Damage is defined as a transfer pump motor impeller IA where the Stellite 6 thermal spray coating is
scratched or worn to base metal or there is deformation or wear on the inner diameter or outer rim from
contact with the inlet check valve.
(d) A serviceable Transfer Pump Motor Impeller is a transfer pump motor impeller that has a transfer pump
motor impeller IA where the Stellite 6 thermal spray coating is not scratched or worn to base metal, and
there is no deformation or wear on the inner diameter or outer rim from contact with the inlet check valve.
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
16 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 17

Group 1, Configuration 1:
Table 2: Right Transfer Pump Housing Inlet Check Valve (ICV) and Transfer Pump Motor Impeller Inlet
Adapter (IA) Detailed Inspection
Refer to the listed
procedures in SB 747-
28A2373 Original Is-
sue or later approved
revisions as an ac-
cepted procedure.
Method Of Compli-
ance
ActionCondition
Do PART 1: PREPARA-
TION
-ACTION 1: Do a Detailed In-
spection (DET) of the right
Transfer Pump Housing Inlet
Check Valve (ICV) for any
damage. (a)
All Airplanes.
-FIGURE 2
Do PART 1: PREPARA-
TION
-ACTION 2: Do a DET of the
right Transfer Pump Motor Im-
peller Inlet Adapter (IA) for any
damage. (c) -FIGURE 7
Do PART 2:
RESTORATION
-Repeat the DET of the right
Transfer Pump Housing ICV for
any damage. (a)
CONDITION 5: NO DAMAGE
FOUND IN THE RIGHT
TRANSFER PUMP HOUSING
ICV. Do PART 1: PREPARA-TION-
-FIGURE 2
FIGURE 4-OPTION 1 (ACTION 1): Re-
place the right Transfer Pump
Housing ICV with a new or ser-
viceable Transfer Pump Hous-
ing ICV. (b)
CONDITION 6: ANY DAMAGE
FOUND IN THE RIGHT
TRANSFER PUMP HOUSING
ICV.
Do PART 2:
RESTORATION
-
Do PART 1: PREPARA-
TION
-OPTION 1 (ACTION 2): Repeat
the DET of the right Transfer
Pump Housing ICV for any
damage. (a) -FIGURE 2
FIGURE 6-OPTION 2 (ACTION 1): Re-
place the right Transfer Pump
Housing with a Transfer Pump
Housing containing a new or
serviceable transfer pump
housing ICV. (b)
Do PART 2:
RESTORATION
-
Do PART 1: PREPARA-
TION
-OPTION 2 (ACTION 2): Repeat
the DET of the right Transfer
Pump Housing ICV for any
damage. (a) -FIGURE 2
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
17 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 18

Group 1, Configuration 1:
Table 2: Right Transfer Pump Housing Inlet Check Valve (ICV) and Transfer Pump Motor Impeller Inlet
Adapter (IA) Detailed Inspection
Refer to the listed
procedures in SB 747-
28A2373 Original Is-
sue or later approved
revisions as an ac-
cepted procedure.
Method Of Compli-
ance
ActionCondition
Do PART 2:
RESTORATION
-Repeat the DET of the right
Transfer Pump Motor Impeller
IA for any damage. (c)
CONDITION 7: NO DAMAGE
FOUND IN THE RIGHT
TRANSFER PUMP MOTOR
IMPELLER IA. Do PART 1: PREPARA-TION-
-FIGURE 7
FIGURE 9-CONDITION 8 (ACTION 1):
Replace the right Transfer
Pump Motor Impeller with a new
or serviceable Transfer Pump
Motor Impeller. (d)
CONDITION 8: ANY DAMAGE
FOUND IN THE RIGHT
TRANSFER PUMP MOTOR
IMPELLER IA.
Do PART 2:
RESTORATION
-
Do PART 1: PREPARA-
TION
-CONDITION 8 (ACTION 2):
Repeat the DET of the right
Transfer Pump Motor Impeller
IA for any damage. (c) -FIGURE 7
(a) Damage is defined as an ICV for which the hinge pin protrudes past the flapper arm on only one side or
there is any metal disk gouging, missing material, corrosion, burrs or raised material found.
(b) A serviceable Transfer Pump Housing ICV is an ICV for which the hinge pin protrudes past the flapper
arm on both sides and there is no metal disk gouging, missing material, corrosion, burrs, or raised mate-
rial.
(c) Damage is defined as a transfer pump motor impeller IA where the Stellite 6 thermal spray coating is
scratched or worn to base metal or there is deformation or wear on the inner diameter or outer rim from
contact with the inlet check valve.
(d) A serviceable Transfer Pump Motor Impeller is a transfer pump motor impeller that has a transfer pump
motor impeller IA where the Stellite 6 thermal spray coating is not scratched or worn to base metal, and
there is no deformation or wear on the inner diameter or outer rim from contact with the inlet check valve.
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
18 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 19 (OCR)

REQUIREMENTS BULLETIN 747-28A2373
ALERT  ALERT
This Figure applies only to: Group 1, Configuration 1.
FWD
TYPICAL
B
LEFT TRANSFER PUMP
HOUSING INLET CHECK VALVE
(TYPICAL)
3082754
FIGURE 1: HORIZONTAL STABILIZER FUEL TANK - LEFT TRANSFER PUMP HOUSING - INLET CHECK
VALVE (ICV) INSPECTION
(SHEET 1 OF 4)
Original Issue: November 06, 2025
Export Controlled ECCN: 9E991  747-28A2373 RB
See page 1 for details  19 of 29

### Page 20 (OCR)

REQUIREMENTS BULLETIN 747-28A2373
ALERT  ALERT
C
(VALVE CLOSED)  PUMP HOUSING  FWD
(TYPICAL)
A-A
INSPECTION
MIRROR
(OPTIONAL)
USE INSPECTION
MIRROR AND ROD IF
NECESSARY
ROD (FOR USE
WITH MIRROR )
PUMP HOUSING  FWD
(VALVE OPEN)
(TYPICAL)  3082761
B-B
FIGURE 1: HORIZONTAL STABILIZER FUEL TANK - LEFT TRANSFER PUMP HOUSING - INLET CHECK
VALVE (ICV) INSPECTION
(SHEET 2 OF 4)
Original Issue: November 06, 2025
747-28A2373 RB
Export Controlled ECCN: 9E991
See page 1 for details  20 of 29

### Page 21 (OCR)

REQUIREMENTS BULLETIN 747-28A2373
ALERT  ALERT
VALVE CLOSED
C-C
VISIBLE  FLAPPER ARM  - VISIBLE
PROTRUSION  PROTRUSION
HINGE PIN
VALVE OPEN
22 DETAILED INSPECTION  3082762
FIGURE 1: HORIZONTAL STABILIZER FUEL TANK - LEFT TRANSFER PUMP HOUSING - INLET CHECK
VALVE (ICV) INSPECTION
(SHEET 3 OF 4)
Original Issue: November 06, 2025
Export Controlled ECCN: 9E991  747-28A2373 RB
See page 1 for details  21 of 29

### Page 22

More DataQtyIdentificationNameTaskStep
(a)1-INLET CHECK VALVEInspect1
(a) Do a Detailed Inspection (DET) of the left Transfer Pump Housing Inlet Check Valve (ICV) for any damage.
Damage is defined as an ICV for which the hinge pin protrudes past the flapper arm on only one side or
there is any metal disk gouging, missing material, corrosion, burrs or raised material found.
FIGURE 1: HORIZONTAL STABILIZER FUEL TANK - LEFT TRANSFER PUMP HOUSING - INLET CHECK
VALVE (ICV) INSPECTION
(SHEET 4 OF 4)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
22 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 23 (OCR)

REQUIREMENTS BULLETIN 747-28A2373
ALERT  ALERT
This Figure applies only to: Group 1, Configuration 1.
FWD
TYPICAL
B
RIGHT TRANSFER PUMP
HOUSING INLET CHECK VALVE
(TYPICAL)
3082763
FIGURE 2: HORIZONTAL STABILIZER FUEL TANK - RIGHT TRANSFER PUMP HOUSING - INLET CHECK
VALVE (ICV) INSPECTION
(SHEET 1 OF 4)
Original Issue: November 06, 2025
Export Controlled ECCN: 9E991  747-28A2373 RB
See page 1 for details  23 of 29

### Page 24 (OCR)

REQUIREMENTS BULLETIN 747-28A2373
ALERT  ALERT
PUMP HOUSING
(VALVE CLOSED)  FWD
(TYPICAL)
A-A
INSPECTION
MIRROR
(OPTIONAL)
USE INSPECTION
MIRROR AND ROD IF
NECESSARY
ROD(FOR USE
WITH MIRROR )
PUMP HOUSING
(VALVE OPEN)
(TYPICAL)  3082764
B-B
FIGURE 2: HORIZONTAL STABILIZER FUEL TANK - RIGHT TRANSFER PUMP HOUSING - INLET CHECK
VALVE (ICV) INSPECTION
(SHEET 2 OF 4)
Original Issue: November 06, 2025
Export Controlled ECCN: 9E991  747-28A2373 RB
See page 1 for details  24 of 29

### Page 25 (OCR)

REQUIREMENTS BULLETIN 747-28A2373
ALERT  ALERT
VALVE CLOSED
C-C
VISIBLE  FLAPPER ARM  - VISIBLE
PROTRUSION  PROTRUSION
HINGE PIN
VALVE OPEN
22 DETAILED INSPECTION  3082766
FIGURE 2: HORIZONTAL STABILIZER FUEL TANK - RIGHT TRANSFER PUMP HOUSING - INLET CHECK
VALVE (ICV) INSPECTION
(SHEET 3 OF 4)
Original Issue: November 06, 2025
Export Controlled ECCN: 9E991  747-28A2373 RB
See page 1 for details  25 of 29

### Page 26

More DataQtyIdentificationNameTaskStep
(a)1-INLET CHECK VALVEInspect1
(a) Do a Detailed Inspection (DET) of the right Transfer Pump Housing Inlet Check Valve (ICV) for any
damage. Damage is defined as an ICV for which the hinge pin protrudes past the flapper arm on only
one side or there is any metal disk gouging, missing material, corrosion, burrs or raised material found.
FIGURE 2: HORIZONTAL STABILIZER FUEL TANK - RIGHT TRANSFER PUMP HOUSING - INLET CHECK
VALVE (ICV) INSPECTION
(SHEET 4 OF 4)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
26 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 27

This Figure applies only to: Group 1, Configuration 1.
FIGURE 7: HORIZONTAL STABILIZER FUEL TANK - TRANSFER PUMP - MOTOR IMPELLER INLET
ADAPTER (IA) INSPECTION
(SHEET 1 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
27 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

### Page 28 (OCR)

REQUIREMENTS BULLETIN 747-28A2373
ALERT  ALERT
FWD
TYPICAL
A-A
FWD
TYPICAL  3082814
DETAILED INSPECTION  B-B
FIGURE 7: HORIZONTAL STABILIZER FUEL TANK - TRANSFER PUMP - MOTOR IMPELLER INLET
ADAPTER (IA) INSPECTION
(SHEET 2 OF 3)
Original Issue: November 06, 2025
Export Controlled ECCN: 9E991  747-28A2373 RB
See page 1 for details  28 of 29

### Page 29

More DataQtyIdentificationNameTaskStep
(a)1-TRANSFER PUMP
MOTOR IMPELLER
INLET ADAPTER
Inspect1
(a) Do a Detailed Inspection (DET) of the Transfer Pump Motor Impeller Inlet Adapter (IA) for any damage.
Damage is defined as a transfer pump motor impeller IA where the Stellite 6 thermal spray coating is
scratched or worn to base metal or there is deformation or wear on the inner diameter or outer rim from
contact with the inlet check valve.
FIGURE 7: HORIZONTAL STABILIZER FUEL TANK - TRANSFER PUMP - MOTOR IMPELLER INLET
ADAPTER (IA) INSPECTION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: November 06, 2025
747-28A2373 RB
29 of 29
REQUIREMENTS BULLETIN 747-28A2373
ALERTALERT

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.