# Boeing Alert Requirements Bulletin 747-38A2146 RB: No revision named, part 4 of 4

- Rights: © The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2024-2408; AD 2025-03-10 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Boeing Alert Requirements Bulletin 747-38A2146 RB](https://openairdocs.org/service-documents/boeing/747-38a2146-rb.md)
- Title as filed: 747-38A2146-00-- RB_Part4
- Pages: 14
- PDF: https://openairdocs.org/files/sha256/cf/9d/cf9dd376655e39762ce6ad1b55aac0acbe5186d08b2dfa23742d4736e9cb545e
- Page: https://openairdocs.org/service-documents/boeing/747-38a2146-rb/file/cf9dd376655e

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1 (OCR)

REQUIREMENTS BULLETIN 747-38A2146
ALERT  ALERT
WATER
DRAIN LINE
WATER SUPPLY LINE
AND HOSE DUCT
WATER
DRAIN LINE
HOSE DUCT
WATER
SUPPLY LINE-
1.50  3030035
FIGURE 24: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 6 OF 9)
Original Issue: August 07, 2024
747-38A2146 RB
Export Controlled ECCN: 9E991
See page 1 for details  142 of 155

### Page 2 (OCR)

REQUIREMENTS BULLETIN 747-38A2146
ALERT  ALERT
WATER
DRAIN LINE
WATER
SUPPLY LINE
AND HOSE
DUCT
STA
680
WATER
DRAIN LINE
WATER
SUPPLY LINE
3030039
FIGURE 24: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 7 OF 9)
Original Issue: August 07, 2024
Export Controlled ECCN: 9E991  747-38A2146 RB
See page 1 for details  143 of 155

### Page 3

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for each airplane.
More DataQtyIdentificationNameTaskStep
(a)1AS1544-05A0810HOSEDUCT, MAX-
WEAR
Install (New)1
Temporary installed
to support water
drain line.
2BACS12GU3K12SCREWRemove2
Install clamp flat
against stanchion.
2BACC10NA113CLAMPInstall (New)
-2BACS12GU3K15SCREWInstall (New)
-1BACS12GU3K13SCREWInstall (New)3
(b)1NMC1005-5CLAMPInstall (New)
(b)1BACC10NA113CLAMPInstall (New)
-1NAS1149D0332JWASHERInstall (New)
-1BACN10YR3CDNUTInstall (New)
-4BACS12GU3K13SCREWInstall (New)4
-4NMC1005-5CLAMPInstall (New)
-4BACC10NA113CLAMPInstall (New)
-4NAS1149D0332JWASHERInstall (New)
-4BACN10YR3CDNUTInstall (New)
-1BACS12GU3K13SCREWInstall (New)5
(b)1NMC1005-5CLAMPInstall (New)
(b)1BACC10NA113CLAMPInstall (New)
-1NAS1149D0332JWASHERInstall (New)
-1BACN10YR3CDNUTInstall (New)
-1BACS12GU3K13SCREWInstall (New)6
-1NMC1005-5CLAMPInstall (New)
-1BACC10NA113CLAMPInstall (New)
-1NAS1149D0332JWASHERInstall (New)
-1BACN10YR3CDNUTInstall (New)
-1417U2917-34HOSE SUPPORT -
POTABLE WATER
Install (Kept)7
(c)-BACS38K1STRAPInstall (New)
FIGURE 24: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 8 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: August 07, 2024
747-38A2146 RB
144 of 155
REQUIREMENTS BULLETIN 747-38A2146
ALERTALERT

### Page 4

More DataQtyIdentificationNameTaskStep
(d)1NAS1611-117AO-RINGInstall (New)8
-1AS4796-12-2750HOSE ASSEMBLYConnect
Install for the connec-
tion with the water
supply system.
1AS1655A12NUT, COUPLINGInstall (Kept)
--BACS38K1STRAPInstall (New)9
(a) Install the hose duct around the water supply line and put the two into position in the clamps.
(b) Make sure the clamp is installed 1.50 inches away from the FWD and AFT ends of the hose duct.
(c) Use the straps to hold the water drain line and the hose support to the water supply line. Make sure that
there is a maximum separation of 8.00 inches between the straps.
(d) Refer to SOPM 20-50-06 as an accepted procedure.
FIGURE 24: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 9 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: August 07, 2024
747-38A2146 RB
145 of 155
REQUIREMENTS BULLETIN 747-38A2146
ALERTALERT

### Page 5 (OCR)

REQUIREMENTS BULLETIN 747-38A2146
ALERT  ALERT
This Figure applies only to: Group 14.
STA
680
STA
540
STA
540
STA  FORWARD CARGO
560_  COMPARTMENT
STA
580
STA
600
STA
620
STA
640
STA
660
STA
680
3029976
FIGURE 25: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 1 OF 10)
Original Issue: August 07, 2024
747-38A2146 RB
Export Controlled ECCN: 9E991
See page 1 for details  146 of 155

### Page 6 (OCR)

REQUIREMENTS BULLETIN 747-38A2146
ALERT  ALERT
STA
540
STA
560
WATER
DRAIN LINE
WATER
DRAIN LINE
3029980
FIGURE 25: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 2 OF 10)
Original Issue: August 07, 2024
Export Controlled ECCN: 9E991  747-38A2146 RB
See page 1 for details  147 of 155

### Page 7 (OCR)

REQUIREMENTS BULLETIN 747-38A2146
ALERT  ALERT
STA
FITTING  540
ASSEMBLY
0.25
0.00  FITTING
FERRULE  ASSEMBLY
4° (MAX)
NBD
WATER SUPPLY LINE CONNECTION
(TYPICAL)  3029983
A-A
FIGURE 25: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 3 OF 10)
Original Issue: August 07, 2024
747-38A2146 RB
Export Controlled ECCN: 9E991
See page 1 for details  148 of 155

### Page 8 (OCR)

REQUIREMENTS BULLETIN 747-38A2146
ALERT  ALERT
STA
580
STA
600
STA
620
IG
SIA
660
STA
680
WATER
• DRAIN LINE
TYPICAL
3029984
FIGURE 25: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 4 OF 10)
Original Issue: August 07, 2024
Export Controlled ECCN: 9E991  747-38A2146 RB
See page 1 for details  149 of 155

### Page 9 (OCR)

REQUIREMENTS BULLETIN 747-38A2146
ALERT  ALERT
STA
600
'CLAMP
WATER
DRAIN LINE
BEFORE
(WATER SUPPLY LINE NOT SHOWN)
WATER
DRAIN LINE
1.50
AFTER
G  3029988
FIGURE 25: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 5 OF 10)
Original Issue: August 07, 2024
747-38A2146 RB
Export Controlled ECCN: 9E991
See page 1 for details  150 of 155

### Page 10 (OCR)

REQUIREMENTS BULLETIN 747-38A2146
ALERT  ALERT
STA
620
SPACER
CLAMP
WATER
DRAIN LINE
BEFORE
(WATER SUPPLY LINE REMOVED)
WATER
DRAIN LINE
STA CLAMP
620  SPACER
AFTER
3029990
FIGURE 25: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 6 OF 10)
Original Issue: August 07, 2024
Export Controlled ECCN: 9E991  747-38A2146 RB
See page 1 for details  151 of 155

### Page 11 (OCR)

REQUIREMENTS BULLETIN 747-38A2146
ALERT  ALERT
STA
660
WATEF
DRAIN LINE
KI
З
ANOT INBO
WATER
DRAIN LINE
6 0
WATER SUPPLY LINE
AND HOSE DUCT
TYPICAL
K  3029997
FIGURE 25: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 7 OF 10)
Original Issue: August 07, 2024
Export Controlled ECCN: 9E991  747-38A2146 RB
See page 1 for details  152 of 155

### Page 12 (OCR)

REQUIREMENTS BULLETIN 747-38A2146
ALERT  ALERT
STA
580
WATER
DRAIN LINE
11)
STA
680
WATER
DRAIN LINE
WATER
/ SUPPLY LINE
3030000
FIGURE 25: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 8 OF 10)
Original Issue: August 07, 2024
Export Controlled ECCN: 9E991  747-38A2146 RB
See page 1 for details  153 of 155

### Page 13

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for each airplane.
More DataQtyIdentificationNameTaskStep
(a)1AS1544-05A0680HOSEDUCT, MAX-
WEAR
Install (New)1
(b)1AS4704-12-2260HOSE ASSEMBLYConnect2
-1AS4704-12-2260HOSE ASSEMBLYInstall (Kept)3
(c)2NAS1611-117AO-RINGInstall (New)
-1AS1654C12SLEEVEInstall (New)
-1AS1655A12NUT, COUPLINGInstall (Kept)
-1BACS12GU3K10SCREWRemove4
-1NAS1149D0332JWASHERRemove
-1NAS43DD6-68FCSPACERInstall (New)5
(d)1BACC10NA113CLAMPInstall (New)
-1NAS1149D0332JWASHERInstall (New)
-1BACS12GU3K34SCREWInstall (New)
-1BACS12GU3K30SCREWRemove6
-1BACC10NA113CLAMPInstall (New)7
-1NAS1149D0332JWASHERInstall (New)
-1BACS12GU3K34SCREWInstall (New)
-1BACS12GU3K18SCREWInstall (New)8
-1NAS1149D0332JWASHERInstall (New)
-1BACC10NA113CLAMPInstall (New)
-1NAS43DD6-13FCSPACERS FOR
BOLTS
Install (New)
-1BACC10DK16CLAMP, LOOPInstall (New)
-1NAS1149D0332JWASHERInstall (New)
-1BACN10YR3CDNUTInstall (New)
-4BACS12GU3K13SCREWInstall (New)9
-4NMC1005-5CLAMPInstall (New)
(d)4BACC10NA113CLAMPInstall (New)
-4NAS1149D0332JWASHERInstall (New)
-4BACN10YR3CDNUTInstall (New)
FIGURE 25: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 9 OF 10)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: August 07, 2024
747-38A2146 RB
154 of 155
REQUIREMENTS BULLETIN 747-38A2146
ALERTALERT

### Page 14

More DataQtyIdentificationNameTaskStep
-1BACS12GU3K11SCREWInstall (New)10
-2NMC1005-5CLAMPInstall (New)
-1BACN10YR3CDNUTInstall (New)
--BACS38K1STRAPInstall (New)11
(a) Install the air duct hose around the water supply line and put the two into position in the clamps.
(b) Make sure there is less than 4.00 degrees difference in alignment between the axis of the water supply
hose end and the axis of the fitting.
(c) Refer to SOPM 20-50-06 as an accepted procedure.
(d) Make sure the clamp is installed 1.50 inches away from the FWD and AFT ends of the duct hose.
FIGURE 25: LEFT SIDE FORWARD CARGO COMPARTMENT - POTABLE WATER SYSTEM - WATER
SUPPLY LINE SHROUD INSTALLATION
(SHEET 10 OF 10)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: August 07, 2024
747-38A2146 RB
155 of 155
REQUIREMENTS BULLETIN 747-38A2146
ALERTALERT

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.