### Page 37

Upper Deck Floor Beam Station (STA) 420 on airplanes that use one of the following drawing installations:
65B10931-134, -248, or -74
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY8C*Bolt3BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt8BACB30MY8K8X
(c) (d)BACB30MY8C*Bolt18BACB30MY8K9X
(c) (d)BACB30GW8*Bolt1BACB30MY8K9X
(c) (d)BACB30MY8C*Bolt1BACB30MY8K11X
(c) (d)BACB30MY6C*Bolt6BACB30NX6K5X
(c) (d)BACB30MY6C*Bolt36BACB30NX6K6X
(c) (d)BACB30MY6C*Bolt18BACB30NX6K7X
(c) (d)BACB30MY6C*Bolt12BACB30NX6K8X
(c)-Collar72BACC30BH6
(c)-Collar38BACC30M8
(c) (d)BACR15BB6D*Rivet1BACR15BB6D11C
or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet55BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet26BACR15BB6D9C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
37 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 38

Upper Deck Floor Beam Station (STA) 420 on airplanes that use one of the following drawing installations:
65B10931-142
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B10931-144Upper Chord165B10931-144
(a) (b)65B10931-149Filler (Strap) L/H165B10931-149
(a) (b)65B10931-150Filler (Strap) R/H165B10931-150
(c) (d)BACB30MY8K*Bolt4BACB30MY8K5X
(c) (d)BACB30MY6K*Bolt6BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt6BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt8BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt6BACB30NX6K6X
(c) (d)BACB30MY6K*Bolt2BACB30NX6K8X
(c) (d)BACB30MY6K*Bolt2BACB30NX6K10X
(c) (d)BACB30MY5K*Bolt5BACB30MY6K5
(c) (d)BACB30MY5K*Bolt1BACB30MY6K6
(c)-Collar30BACC30BH6
(c)-Collar6BACC30M6
(c)-Collar4BACC30M8
(c) (d)BACR15BB5D*Rivet172BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet13BACR15BB5D9C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D11C
or BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet5BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet3BACR15BB6D9C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D10C
or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D11C
or BACR15BB7D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
38 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 39

Upper Deck Floor Beam Station (STA) 420 on airplanes that use one of the following drawing installations:
65B10931-142
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15CE5D*Rivet2BACR15GF5D7 or
BACR15GF6D*
(c) (d)BACR15CE6D*Rivet1BACR15GF6D8 or
BACR15GF7D*
(c) (d)BACR15CE6D*Rivet1BACR15GF6D10 or
BACR15GF7D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 1-2, 5-6:
Upper Deck Floor Beam Station (STA) 440 on airplanes that use one of the following drawing installations:
65B10932-14 or -153
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B10932-19 or
65B10932-163
Upper Chord165B10932-19 or
65B10932-163
(a) (b)65B10932-21Filler (Strap) L/H165B10932-21
(a) (b)65B10932-22Filler (Strap) R/H165B10932-22
(c) (d)BACB30MY8K*Bolt4BACB30MY8K6X
(c) (d)BACB30MY6K*Bolt2BACB30NX6K5X
(c)-Collar2BACC30BH6
(c)-Collar4BACC30M8
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
39 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 40

Group 1-2, 5-6:
Upper Deck Floor Beam Station (STA) 440 on airplanes that use one of the following drawing installations:
65B10932-14 or -153
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet138BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet34BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet2BACR15BB6D10C
or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D11C
or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet8BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet19BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15CE6D*Rivet2BACR15GF6D11 or
BACR15GF7D*
(c) (d)BACR15CE6D*Rivet2BACR15GF6D12 or
BACR15GF7D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
40 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 41

Group 1-2, 5-6:
Upper Deck Floor Beam Station (STA) 440 on airplanes that use one of the following drawing installations:
65B10932-5001, -5002, -5003, -5004, -5005, or -5006
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B10932-135 or
65B10932-138 or
65B10932-143 or
65B10932-148 or
65B10932-149 or
65B10932-552
Upper Chord165B10932-135 or
65B10932-138 or
65B10932-143 or
65B10932-148 or
65B10932-149 or
65B10932-552
(a) (b)65B25842-19Angle L/H165B25842-19
(a) (b)65B25842-18Angle R/H165B25842-18
(c) (d)BACB30MY5K*Bolt67BACB30MY6K4
(c) (d)BACB30MY8K*Bolt4BACB30MY8K6X
(c) (d)BACB30NW6K*Bolt5BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt49BACB30NW6K6X
(c) (d)BACB30MY6K*Bolt11BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt13BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt9BACB30NX6K6X
(c) (d)BACB30MY6K*Bolt1BACB30NX6K8X
(c)-Collar121BACC30M6
(c)-Collar4BACC30M8
(c)-Collar34BACC30BH6
(c) (d)BACR15BA5D*Rivet1BACR15BA5D6C or
BACR15BA6D*C
(c) (d)BACR15BA8D*Rivet3BACR15BA8D10C
or BACR15BA9D*C
(c) (d)BACR15BB5D*Rivet96BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet13BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet11BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D8C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
41 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 42

Group 1-2, 5-6:
Upper Deck Floor Beam Station (STA) 440 on airplanes that use one of the following drawing installations:
65B10932-5001, -5002, -5003, -5004, -5005, or -5006
NotesExisting Part NumberNameQTYPart Number /
Specification
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 1-2, 5-6:
Upper Deck Floor Beam Station (STA) 440 on airplanes that use one of the following drawing installations:
65B10932-49 and -50
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B10932-57Upper Chord - Left165B10932-57
(a) (b)65B10932-58Upper Chord - Right165B10932-58
(a) (b)65B10932-21Filler (Strap) L/H165B10932-21
(a) (b)65B10932-22Filler (Strap) R/H165B10932-22
(c) (d)BACB30MY6C*Bolt7BACB30MY6K3X
(c) (d)BACB30MY6C*Bolt14BACB30MY6K4X
(c) (d)BACB30MY6C*Bolt4BACB30MY6K5X
(c) (d)BACB30MY6C*Bolt8BACB30MY6K6X
(c) (d)BACB30MY8C*Bolt2BACB30MY8K4X
(c) (d)BACB30MY8C*Bolt2BACB30MY8K5X
(c) (d)BACB30NW6C*Bolt14BACB30NW6K4X
(c) (d)BACB30NW8C*Bolt4BACB30NW8K4X
(c)-Collar47BACC30M6
(c)-Collar8BACC30M8
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
42 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 43

Group 1-2, 5-6:
Upper Deck Floor Beam Station (STA) 440 on airplanes that use one of the following drawing installations:
65B10932-49 and -50
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet64BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet3BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet8BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15CE6D*Rivet2BACR15GF6D11 or
BACR15GF7D*
(c) (d)BACR15CE6D*Rivet2BACR15GF6D12 or
BACR15GF7D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 460
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B10933-110 or
65B10933-133 or
65B10933-137 or
65B10933-141 or
65B10933-142 or
65B10933-143
Upper Chord165B10933-110 or
65B10933-133 or
65B10933-137 or
65B10933-141 or
65B10933-142 or
65B10933-143
(a) (b)65B25842-8Angle L/H165B25842-8
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
43 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 44

Group 5:
Upper Deck Floor Beam Station (STA) 460
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B25842-7Angle R/H165B25842-7
(c) (d)BACB30MY5K*Bolt10BACB30MY6K4
(c) (d)BACB30MY5K*Bolt8BACB30MY6K5
(c) (d)BACB30MY8K*Bolt4BACB30MY8K6X
(c) (d)BACB30NW6K*Bolt4BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt6BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt44BACB30NW6K6X
(c) (d)BACB30MY6K*Bolt51BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt24BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt13BACB30NX6K6X
(c)-Collar160BACC30M6
(c)-Collar4BACC30M8
(c) (d)BACR15BA5D*Rivet1BACR15BA5D7C or
BACR15BA6D*C
(c) (d)BACR15BA6D*Rivet9BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet125BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet13BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet9BACR15BB6D7C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
44 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 45

Group 5:
Upper Deck Floor Beam Station (STA) 460
NotesExisting Part NumberNameQTYPart Number /
Specification
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 480
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B10934-124 or
65B10934-151 or
65B10934-165 or
65B10934-166
Upper Chord165B10934-124 or
65B10934-151 or
65B10934-165 or
65B10934-166
(a) (b)65B25842-6 or
65B25842-11
Angle L/H165B25842-6 or
65B25842-11
(a) (b)65B25842-5Angle R/H165B25842-5
(c) (d)BACB30MY5K*Bolt43BACB30MY6K4
(c) (d)BACB30MY5K*Bolt2BACB30MY6K5
(c) (d)BACB30MY5K*Bolt2BACB30MY6K6
(c) (d)BACB30NW5K*Bolt7BACB30NW6K4
(c) (d)BACB30NW6K*Bolt10BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt36BACB30NW6K6X
(c) (d)BACB30MY6K*Bolt27BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt2BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt10BACB30NX6K6X
(c) (d)BACB30MY6K*Bolt1BACB30NX6K7X
(c)-Collar100BACC30M6
(c)-Collar40BACC30BH6
(c) (d)BACR15BA3D*Rivet2BACR15BA3D4C or
BACR15BA4D*C
(c) (d)BACR15BA6D*Rivet14BACR15BA6D9C or
BACR15BA7D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
45 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 46

Group 5:
Upper Deck Floor Beam Station (STA) 480
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet130BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet6BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet16BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet3BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D8C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 500
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B10935-123 or
65B10935-126
Upper Chord165B10935-123 or
65B10935-126
(a) (b)65B25842-12Reinforcement Angle L/H165B25842-12
(a) (b)65B25842-13Reinforcement Angle R/H165B25842-13
(c) (d)BACB30MY10K*Bolt2BACB30MY10K10X
(c) (d)BACB30MY5K*Bolt13BACB30MY6K4
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
46 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 47

Group 5:
Upper Deck Floor Beam Station (STA) 500
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY8K*Bolt2BACB30MY8K5X
(c) (d)BACB30NW6K*Bolt37BACB30NW6K6X
(c) (d)BACB30MY6K*Bolt1BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt65BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt14BACB30NX6K3X
(c)-Collar50BACC30M6
(c)-Collar80BACC30BH6
(c)-Collar2BACC30M8
(c)-Collar2BACC30M10
(c) (d)BACR15BB5D*Rivet136BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet13BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet17BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15CE5D*Rivet1BACR15GF5D5 or
BACR15GF6D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
47 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 48

Upper Deck Floor Beam Station (STA) 520 on airplanes that use one of the following drawing installations:
65B10936-10
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B10936-12Upper Chord165B10936-12
(a) (b)65B10936-5Filler (Strap) L/H165B10936-5
(a) (b)65B10936-6Filler (Strap) R/H165B10936-6
(c) (d)BACB30FM6*Bolt24BACB30NX6K4X
(c) (d)BACB30FM6*Bolt6BACB30NX6K5X
(c)-Collar30BACC30BH6
(c) (d)MS20426D6Rivet1BACR15BA6D8C or
BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet96BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet2BACR15BB6D11C
or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet40BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet58BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet2BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet13BACR15BB6D9C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
48 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 49

Upper Deck Floor Beam Station (STA) 520 on airplanes that use one of the following drawing installations:
65B10936-10
NotesExisting Part NumberNameQTYPart Number /
Specification
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 520 on airplanes that use one of the following drawing installations:
65B10936-5001, -5002, -5003, or -5005
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B10936-119 or
65B10936-128 or
65B10936-122
Upper Chord165B10936-119 or
65B10936-128 or
65B10936-122
(a) (b)65B25842-15Angle L/H165B25842-15
(a) (b)65B25842-16Angle R/H165B25842-16
(c) (d)BACB30MY5K*Bolt28BACB30MY6K4
(c) (d)BACB30NW6K*Bolt20BACB30NW6K6X
(c) (d)BACB30MY6K*Bolt51BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt5BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt16BACB30NX6K6X
(c)-Collar48BACC30M6
(c)-Collar72BACC30BH6
(c) (d)BACR15BB5D*Rivet139BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet13BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet16BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D7C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
49 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 50

Upper Deck Floor Beam Station (STA) 520 on airplanes that use one of the following drawing installations:
65B10936-5001, -5002, -5003, or -5005
NotesExisting Part NumberNameQTYPart Number /
Specification
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 520 on airplanes that use one of the following drawing installations:
65B10936-145, or -176
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B10936-138Upper Chord165B10936-138
(a) (b)65B10936-150Reinforcement Angle L/H165B10936-150
(a) (b)65B10936-149Reinforcement Angle R/H165B10936-149
(c) (d)BACB30MY6K*Bolt2BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt16BACB30NX6K6X
(c) (d)BACB30MY6K*Bolt9BACB30NX6K8X
(c)-Collar39BACC30BH6
(c) (d)BACR15BB5D*Rivet93BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet4BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet25BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet39BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet2BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet47BACR15BB6D9C or
BACR15BB7D*C
(c) (d)BACR15CE5D*Rivet40BACR15GF6D11 or
BACR15GF7D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
50 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 51

Upper Deck Floor Beam Station (STA) 520 on airplanes that use one of the following drawing installations:
65B10936-145, or -176
NotesExisting Part NumberNameQTYPart Number /
Specification
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 520 on airplanes that use one of the following drawing installations:
65B10936-48
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B10936-91Upper Chord165B10936-91
(a) (b)65B10936-93Filler (Strap) L/H165B10936-93
(a) (b)65B10936-92Filler (Strap) R/H165B10936-92
(c) (d)BACB30MY8C*Bolt4BACB30MY8K11X
(c) (d)BACB30MY8C*Bolt4BACB30MY8K8X
(c) (d)BACB30MY8C*Bolt18BACB30MY8K9X
(c) (d)BACB30NW6C*Bolt2BACB30NW6K6X
(c) (d)BACB30NW6C*Bolt2BACB30NW6K9X
(c) (d)BACB30NW8C*Bolt4BACB30NW8K10X
(c) (d)BACB30MY6C*Bolt36BACB30NX6K5X
(c) (d)BACB30MY6C*Bolt3BACB30NX6K6X
(c) (d)BACB30MY6C*Bolt31BACB30NX6K7X
(c) (d)BACB30MY6C*Bolt6BACB30NX6K8X
(c) (d)BACB30FM6*Bolt1BACB30NX6K8X
(c) (d)BACB30MB6*Bolt1BACB30NX6K9X
(c)-Collar4BACC30M6
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
51 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 52

Upper Deck Floor Beam Station (STA) 520 on airplanes that use one of the following drawing installations:
65B10936-48
NotesExisting Part NumberNameQTYPart Number /
Specification
(c)-Collar26BACC30M8
(c)-Collar78BACC30BH6
(c) (d)BACR15BB6D*Rivet141BACR15BB6D9C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet5BACR15BB6D10C
or BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 1-4:
Upper Deck Floor Beam Station (STA) 540
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06829-1 or
65B06818-50
Upper Chord165B06829-1 or
65B06818-50
(a) (b)65B06818-13Reinforcement Angle L/H165B06818-13
(a) (b)65B06818-14Reinforcement Angle R/H165B06818-14
(c) (d)BACB30FM5*Bolt8BACB30VT6K3
(c) (d)BACB30FM5*Bolt91BACB30VT6K4
(c) (d)BACB30FM5*Bolt18BACB30VT6K5
(c) (d)BACB30FM6*Bolt8BACB30NX6K3X
(c) (d)BACB30FM6*Bolt2BACB30NX6K4X
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
52 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 53

Group 1-4:
Upper Deck Floor Beam Station (STA) 540
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30FM6*Bolt8BACB30NX6K5X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30MY8C*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt4BACB30MY8K8X
(c) (d)BACB30LB6*Bolt8BACB30VW6A5UX
(c) (d)BACB30FM6*Bolt2BACB30NX6K9X
(c) (d)BACB30FN6*Bolt8BACB30NX6K9X
(c) (d)BACB30FN6*Bolt12BACB30NW6K5X
(c) (d)BACB30FN6*Bolt14BACB30NW6K6X
(c)-Collar20BACC30BH6
(c)-Collar117BACC30BL6
(c)-Collar36BACC30M6
(c)-Collar16BACC30M8
(c) (d)MS20426D5Rivet1BACR15BA5D5C or
BACR15BA6D*C
(c) (d)BACR15BB5D*Rivet143BACR15BB5D5C or
BACR15BA6D*C
(c) (d)BACR15BB5D*Rivet31BACR15BB5D6C or
BACR15BA6D*C
(c) (d)BACR15BB5D*Rivet4BACR15BB5D7C or
BACR15BA6D*C
(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or
BACR15BA4D*C
(c) (d)MS20426D6Rivet2BACR15BA6D9C or
BACR15BA7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
53 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 54

Group 1-4:
Upper Deck Floor Beam Station (STA) 540
NotesExisting Part NumberNameQTYPart Number /
Specification
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5-6:
Upper Deck Floor Beam Station (STA) 540
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06818-65Upper Chord165B06818-65
(a) (b)65B06818-68Reinforcement Angle L/H165B06818-68
(a) (b)65B06818-69Reinforcement Angle R/H165B06818-69
(c) (d)BACB30MY5K*Bolt78BACB30MY6K4
(c) (d)BACB30MY5K*Bolt14BACB30MY6K5
(c) (d)BACB30MY6K*Bolt8BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c) (d)BACB30MY8K*Bolt14BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X
(c)-Collar20BACC30BH6
(c)-Collar126BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet36BACR15BB5D5C or
BACR15BA6D*C
(c) (d)BACR15BB5D*Rivet128BACR15BB5D6C or
BACR15BA6D*C
(c) (d)BACR15BB5D*Rivet4BACR15BB5D7C or
BACR15BA6D*C
(c) (d)BACR15BB6D*Rivet2BACR15BB6D6C or
BACR15BA7D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
54 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 55

Group 5-6:
Upper Deck Floor Beam Station (STA) 540
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB6D*Rivet6BACR15BB6D7C or
BACR15BA7D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D8C or
BACR15BA7D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 1-4:
Upper Deck Floor Beam Station (STA) 560
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06819-600 or
65B06819-601
Upper Chord165B06819-600 or
65B06819-601
(a) (b)65B06819-3Reinforcement Angle L/H165B06819-3
(a) (b)65B06819-4Reinforcement Angle R/H165B06819-4
(c) (d)BACB30FM5*Bolt8BACB30VT6K3
(c) (d)BACB30FM5*Bolt90BACB30VT6K4
(c) (d)BACB30FM5*Bolt18BACB30VT6K5
(c) (d)BACB30FM6*Bolt6BACB30NX6K3X
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
55 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 56

Group 1-4:
Upper Deck Floor Beam Station (STA) 560
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30FM6*Bolt20BACB30NX6K5X
(c) (d)BACB30FM6*Bolt1BACB30NX6K6X
(c) (d)BACB30FM6*Bolt1BACB30NX6K7X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FN6*Bolt2BACB30NW6K3X
(c) (d)BACB30LB6*Bolt4BACB30VW6A5UX
(c) (d)BACB30MY8C*Bolt8BACB30MY8K7X
(c) (d)BACB30MY6K*Bolt1BACB30NX6K6X
(c) (d)BACB30MY6K*Bolt3BACB30NX6K7X
(c) (d)BACB30NW6K*Bolt1BACB30NW6K5X
(c) (d)BACB30FM6*Bolt2BACB30NX6K9X
(c) (d)BACB30FN6*Bolt39BACB30NW6K6X
(c) (d)BACB30MY8C*Bolt8BACB30MY8K8X
(c) (d)BACR15BB5D*Rivet139BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet63BACR15BB5D6C or
BACR15BB6D*C
(c) (d)MS20426D5Rivet1BACR15BA5D6C or
BACR15BB6D*C
(c) (d)BACR15BA3D*Rivet12BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA6D*Rivet5BACR15BA6D9C or
BACR15BA7D*C
(c)-Collar116BACC30BL6
(c)-Collar32BACC30BH6
(c)-Collar48BACC30M6
(c)-Collar16BACC30M8
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
56 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 57

Group 1-4:
Upper Deck Floor Beam Station (STA) 560
NotesExisting Part NumberNameQTYPart Number /
Specification
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5-6:
Upper Deck Floor Beam Station (STA) 560
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06819-38 or
65B26467-50 or
65B26467-56
Upper Chord165B06819-38 or
65B26467-50 or
65B26467-56
(a) (b)65B06819-41 or
65B26467-52
Reinforcement Angle L/H165B06819-41 or
65B26467-52
(a) (b)65B06819-42 or
65B26467-53
Reinforcement Angle R/H165B06819-42 or
65B26467-53
(c) (d)BACB30MY5K*Bolt2BACB30MY6K3
(c) (d)BACB30MY5K*Bolt80BACB30MY6K4
(c) (d)BACB30MY5K*Bolt14BACB30MY6K5
(c) (d)BACB30MY6K*Bolt12BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt8BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt4BACB30NX6K6X
(c) (d)BACB30MY8K*Bolt18BACB30MY8K7X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X
(c) (d)BACR15BB5D*Rivet23BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet145BACR15BB5D5C or
BACR15BB6D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
57 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 58

Group 5-6:
Upper Deck Floor Beam Station (STA) 560
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c)-Collar24BACC30BH6
(c)-Collar130BACC30M6
(c)-Collar18BACC30M8
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 1-4:
Upper Deck Floor Beam Station (STA) 580
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06820-7 or
65B06820-37
Upper Chord165B06820-7 or
65B06820-37
(a) (b)65B06820-3Reinforcement Angle L/H165B06820-3
(a) (b)65B06820-4Reinforcement Angle R/H165B06820-4
(c) (d)BACB30MY8C*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt4BACB30MY8K8X
(c) (d)BACB30FN5*Bolt2BACB30NW5K4X
(c) (d)BACB30FM5*Bolt8BACB30VT6K3
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
58 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 59

Group 1-4:
Upper Deck Floor Beam Station (STA) 580
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30FM5*Bolt92BACB30VT6K4
(c) (d)BACB30FM5*Bolt16BACB30VT6K5
(c) (d)BACB30FM6*Bolt10BACB30NX6K3X
(c) (d)BACB30VT6K*Bolt8BACB30NX6K3X
(c) (d)BACB30FM6*Bolt14BACB30NX6K5X
(c) (d)BACB30FN6*Bolt10BACB30NW6K4X
(c) (d)BACB30FN6*Bolt30BACB30NW6K6X
(c)-Collar32BACC30BH6
(c)-Collar116BACC30BL6
(c)-Collar2BACC30M5
(c)-Collar40BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet135BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet28BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BA5D*Rivet1BACR15BA5D5C or
BACR15BA6D*C
(c) (d)BACR15BA6D*Rivet4BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
59 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 60

Group 1-4:
Upper Deck Floor Beam Station (STA) 580
NotesExisting Part NumberNameQTYPart Number /
Specification
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5-6:
Upper Deck Floor Beam Station (STA) 580
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06820-26Upper Chord165B06820-26
(a) (b)65B06820-29Reinforcement Angle L/H165B06820-29
(a) (b)65B06820-30Reinforcement Angle R/H165B06820-30
(c) (d)BACB30MY5K*Bolt80BACB30MY6K4
(c) (d)BACB30MY5K*Bolt14BACB30MY6K5
(c) (d)BACB30MY6K*Bolt8BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c) (d)BACB30MY8K*Bolt14BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X
(c)-Collar20BACC30BH6
(c)-Collar128BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BB5D*Rivet146BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet14BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
60 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 61

Group 5-6:
Upper Deck Floor Beam Station (STA) 580
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BA3B*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 1-4:
Upper Deck Floor Beam Station (STA) 600
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06821-9 or
65B06821-37
Upper Chord165B06821-9 or
65B06821-37
(a) (b)65B06821-3Reinforcement Angle L/H165B06821-3
(a) (b)65B06821-4Reinforcement Angle R/H165B06821-4
(c) (d)BACB30MY8C*Bolt4BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt12BACB30MY8K8X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FM5*Bolt4BACB30VT6K3
(c) (d)BACB30FM5*Bolt81BACB30VT6K4
(c) (d)BACB30FM5*Bolt33BACB30VT6K5
(c) (d)BACB30FM5*Bolt5BACB30VT6K6
(c) (d)BACB30FM6*Bolt7BACB30NX6K3X
(c) (d)BACB30FM6*Bolt10BACB30NX6K5X
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
61 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 62

Group 1-4:
Upper Deck Floor Beam Station (STA) 600
NotesExisting Part NumberNameQTYPart Number /
Specification
(c)-Collar19BACC30BH6
(c)-Collar124BACC30BL6
(c)-Collar28BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet136BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet28BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet4BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BA5D*Rivet1BACR15BA5D5C or
BACR15BA6D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
62 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 63

Group 5-6:
Upper Deck Floor Beam Station (STA) 600
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06821-27 or
65B26467-19
Upper Chord165B06821-27 or
65B26467-19
(a) (b)65B06821-30 or
65B26467-15
Reinforcement Angle L/H165B06821-30 or
65B26467-15
(a) (b)65B06821-31 or
65B26467-16
Reinforcement Angle R/H165B06821-31 or
65B26467-16
(c) (d)BACB30MY5K*Bolt11BACB30MY6K3
(c) (d)BACB30MY5K*Bolt82BACB30MY6K4
(c) (d)BACB30MY5K*Bolt17BACB30MY6K5
(c) (d)BACB30MY5K*Bolt2BACB30MY6K6
(c) (d)BACB30MY6K*Bolt8BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt14BACB30NX6K5X
(c) (d)BACB30MY8K*Bolt14BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X
(c)-Collar22BACC30BH6
(c)-Collar146BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BB5D*Rivet129BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet13BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet8BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
63 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 64

Group 5-6:
Upper Deck Floor Beam Station (STA) 600
NotesExisting Part NumberNameQTYPart Number /
Specification
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 1-4:
Upper Deck Floor Beam Station (STA) 620
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06822-3 or
65B06822-42
Upper Chord165B06822-3 or
65B06822-42
(a) (b)65B06822-9Reinforcement Angle L/H165B06822-9
(a) (b)65B06822-10Reinforcement Angle R/H165B06822-10
(c) (d)BACB30MY8C*Bolt4BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt12BACB30MY8K8X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FM5*Bolt6BACB30VT6K3
(c) (d)BACB30FM5*Bolt96BACB30VT6K4
(c) (d)BACB30FM5*Bolt19BACB30VT6K5
(c) (d)BACB30FM6*Bolt10BACB30NX6K3X
(c) (d)BACB30FM6*Bolt12BACB30NX6K5X
(c) (d)BACB30FM6*Bolt2BACB30NX6K9X
(c) (d)BACB30FN6*Bolt44BACB30NW6K6X
(c)-Collar122BACC30BL6
(c)-Collar24BACC30BH6
(c)-Collar46BACC30M6
(c)-Collar16BACC30M8
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
64 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 65

Group 1-4:
Upper Deck Floor Beam Station (STA) 620
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet133BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet27BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D7C or
BACR15BB6D*C
(c) (d)MS20426D5Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5-6:
Upper Deck Floor Beam Station (STA) 620
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06822-30 or
65B26467-44
Upper Chord165B06822-30 or
65B26467-44
(a) (b)65B06822-33 or
65B26467-46
Reinforcement Angle L/H165B06822-33 or
65B26467-46
(a) (b)65B06822-34 or
65B26467-47
Reinforcement Angle R/H165B06822-34 or
65B26467-47
(c) (d)BACB30MY5K*Bolt82BACB30MY6K4
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
65 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 66

Group 5-6:
Upper Deck Floor Beam Station (STA) 620
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY5K*Bolt14BACB30MY6K5
(c) (d)BACB30MY6K*Bolt8BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c) (d)BACB30MY8K*Bolt14BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
(c) (d)BACB30NX5K*Bolt4BACB30NX6K3
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X
(c)-Collar24BACC30BH6
(c)-Collar130BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BB5D*Rivet148BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet13BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3D*Rivet12BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
66 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 67

Group 5-6:
Upper Deck Floor Beam Station (STA) 620
NotesExisting Part NumberNameQTYPart Number /
Specification
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 1-4:
Upper Deck Floor Beam Station (STA) 640
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06823-9 or
65B06823-36
Upper Chord165B06823-9 or
65B06823-36
(a) (b)65B06823-3Reinforcement Angle L/H165B06823-3
(a) (b)65B06823-4Reinforcement Angle R/H165B06823-4
(c) (d)BACB30MY8C*Bolt4BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt12BACB30MY8K8X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4X
(c) (d)BACB30FM5*Bolt6BACB30VT6K3
(c) (d)BACB30FM5*Bolt91BACB30VT6K4
(c) (d)BACB30FM5*Bolt19BACB30VT6K5
(c) (d)BACB30FM6*Bolt10BACB30NX6K3X
(c) (d)BACB30FM6*Bolt10BACB30NX6K5X
(c) (d)BACB30FM6*Bolt2BACB30NX6K9X
(c) (d)BACB30FN6*Bolt38BACB30NW6K6X
(c)-Collar22BACC30BH6
(c)-Collar116BACC30BL6
(c)-Collar40BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet136BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet24BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15CE5B*Rivet1BACR15GF5D6 or
BACR15GF6D*
(c) (d)BACR15BA6D*Rivet4BACR15BA6D9C or
BACR15BA7D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
67 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 68

Group 1-4:
Upper Deck Floor Beam Station (STA) 640
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5-6:
Upper Deck Floor Beam Station (STA) 640
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06823-39 or
65B06823-31
Upper Chord165B06823-39 or
65B06823-31
(a) (b)65B06823-42 or
65B06823-3
Reinforcement Angle L/H165B06823-42 or
65B06823-3
(a) (b)65B06823-43 or
65B06823-4
Reinforcement Angle R/H165B06823-43 or
65B06823-4
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30MY5K*Bolt76BACB30NX5K4X
(c) (d)BACB30MY5K*Bolt16BACB30NX5K5X
(c) (d)BACB30MY6K*Bolt8BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c) (d)BACB30MY8K*Bolt2BACB30MY8K9X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt24BACB30NW6K6X
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
68 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 69

Group 5-6:
Upper Deck Floor Beam Station (STA) 640
NotesExisting Part NumberNameQTYPart Number /
Specification
(c)-Collar92BACC30BH5
(c)-Collar20BACC30BH6
(c)-Collar32BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BB5D*Rivet146BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet14BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 1-4:
Upper Deck Floor Beam Station (STA) 660
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06824-9Upper Chord165B06824-9
(a) (b)65B06824-3Reinforcement Angle L/H165B06824-3
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
69 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 70

Group 1-4:
Upper Deck Floor Beam Station (STA) 660
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06824-4Reinforcement Angle R/H165B06824-4
(c) (d)BACB30MY8C*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt4BACB30MY8K8X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FM5*Bolt6BACB30VT6K3
(c) (d)BACB30FM5*Bolt93BACB30VT6K4
(c) (d)BACB30FM5*Bolt17BACB30VT6K5
(c) (d)BACB30FM6*Bolt10BACB30NX6K3X
(c) (d)BACB30FM6*Bolt12BACB30NX6K5X
(c) (d)BACB30FM6*Bolt2BACB30NX6K7X
(c) (d)BACB30FN6*Bolt8BACB30NW6K4X
(c) (d)BACB30FN6*Bolt10BACB30NW6K5X
(c) (d)BACB30FN6*Bolt10BACB30NW6K6X
(c)-Collar24BACC30BH6
(c)-Collar116BACC30BL6
(c)-Collar30BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet141BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet26BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
70 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 71

Group 1-4:
Upper Deck Floor Beam Station (STA) 660
NotesExisting Part NumberNameQTYPart Number /
Specification
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5-6:
Upper Deck Floor Beam Station (STA) 660
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06824-49 or
65B26467-24 or
65B06824-45
Upper Chord165B06824-49 or
65B26467-24 or
65B06824-45
(a) (b)65B06824-3Reinforcement Angle L/H165B06824-3
(a) (b)65B06824-4Reinforcement Angle R/H165B06824-4
(a) (b) (g)65B06824-52 or
65B26467-22
Reinforcement Angle165B06824-52 or
65B26467-22
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30MY6K*Bolt20BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt4BACB30NX6K6X
(c) (d)BACB30MY8K*Bolt2BACB30MY8K9X
(c) (d)BACB30MY5K*Bolt84BACB30MY6K4
(c) (d)BACB30MY5K*Bolt52BACB30MY6K5
(c) (d)BACB30MY5K*Bolt2BACB30MY6K6
(c) (d)BACB30NX6K*Bolt2BACB30NX6K5X
(c) (d)BACB30NW6K*Bolt6BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt6BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt10BACB30NW6K6X
(c)-Collar26BACC30BH6
(c)-Collar160BACC30M6
(c)-Collar16BACC30M8
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
71 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 72

Group 5-6:
Upper Deck Floor Beam Station (STA) 660
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet143BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet9BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3D*Rivet8BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Group 1-4:
Upper Deck Floor Beam Station (STA) 680
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06825-13Upper Chord165B06825-13
(a) (b)65B06825-3Reinforcement Angle L/H165B06825-3
(a) (b)65B06825-4Reinforcement Angle R/H165B06825-4
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
72 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 73

Group 1-4:
Upper Deck Floor Beam Station (STA) 680
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY8C*Bolt4BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt12BACB30MY8K8X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FM5*Bolt6BACB30VT6K3
(c) (d)BACB30FM5*Bolt91BACB30VT6K4
(c) (d)BACB30FM5*Bolt19BACB30VT6K5
(c) (d)BACB30FM6*Bolt18BACB30NX6K3X
(c) (d)BACB30FM6*Bolt12BACB30NX6K5X
(c) (d)BACB30FM6*Bolt8BACB30NX6K8X
BACB30FM6*Bolt2BACB30NX6K9X
(c) (d)BACB30FN6*Bolt32BACB30NW6K6X
(c)-Collar40BACC30BH6
(c)-Collar126BACC30BL6
(c)-Collar34BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet144BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet25BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
73 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 74

Group 1-4:
Upper Deck Floor Beam Station (STA) 680
NotesExisting Part NumberNameQTYPart Number /
Specification
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5-6:
Upper Deck Floor Beam Station (STA) 680
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06825-41 or
65B26467-27 or
65B06825-38
Upper Chord165B06825-41 or
65B26467-27 or
65B06825-38
(a) (b)65B06825-3Reinforcement Angle L/H165B06825-3
(a) (b)65B06825-4Reinforcement Angle R/H165B06825-4
(a) (b) (g)65B06825-44 or
65B26467-28
Reinforcement Angle165B06825-44 or
65B26467-28
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K4X
(c) (d)BACB30MY5K*Bolt92BACB30MY6K4
(c) (d)BACB30MY5K*Bolt24BACB30MY6K5
(c) (d)BACB30NW6K*Bolt6BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt4BACB30NW6K5X
(c)-Collar2BACC30BH6
(c)-Collar138BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet145BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet10BACR15BB5D7C or
BACR15BB6D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
74 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 75

Group 5-6:
Upper Deck Floor Beam Station (STA) 680
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet1BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet7BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BA3D*Rivet8BACR15BA3D7C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Group 1-4:
Upper Deck Floor Beam Station (STA) 700
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06826-9 or
65B06826-35 or
65B06826-39 or
65B06826-50 or
65B26467-27 or
65BE0212-3
Upper Chord165B06826-9 or
65B06826-35 or
65B06826-39 or
65B06826-50 or
65B26467-27 or
65BE0212-3
(a) (b)65B06826-3 or
65BE0212-17
Reinforcement Angle L/H165B06826-3 or
65BE0212-17
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
75 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 76

Group 1-4:
Upper Deck Floor Beam Station (STA) 700
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06826-4 or
65BE0212-18
Reinforcement Angle R/H165B06826-4 or
65BE0212-18
(a) (b) (g)65B06826-42 or
65B26467-28
Reinforcement Angle165B06826-42 or
65B26467-28
(c) (d)BACB30MY8C*Bolt4BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt12BACB30MY8K8X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FN6*Bolt24BACB30NW6K6X
(c) (d)BACB30FM5*Bolt6BACB30VT6K3
(c) (d)BACB30FM5*Bolt93BACB30VT6K4
(c) (d)BACB30FM5*Bolt16BACB30VT6K5
(c) (d)BACB30FM6*Bolt10BACB30NX6K3X
(c) (d)BACB30FM6*Bolt12BACB30NX6K5X
(c) (d)BACB30FM6*Bolt2BACB30NX6K9X
(c)-Collar24BACC30BH6
(c)-Collar105BACC30BL6
(c)-Collar26BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet141BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet27BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet3BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BA5D*Rivet1BACR15BA5D6C or
BACR15BA6D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA8D*Rivet2BACR15BA8D10C
or BACR15BA9D*C
(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or
BACR15BA4*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
76 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 77

Group 1-4:
Upper Deck Floor Beam Station (STA) 700
NotesExisting Part NumberNameQTYPart Number /
Specification
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Group 5-6:
Upper Deck Floor Beam Station (STA) 700
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06826-9 or
65B06826-39 or
65B06826-50 or
65B26467-27
Upper Chord165B06826-9 or
65B06826-39 or
65B06826-50 or
65B26467-27
(a) (b)65B06826-3Reinforcement Angle L/H165B06826-3
(a) (b)65B06826-4Reinforcement Angle R/H165B06826-4
(a) (b) (g)65B06826-42 or
65B26467-28
Reinforcement Angle165B06826-42 or
65B26467-28
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30MY5K*Bolt91BACB30MY6K4
(c) (d)BACB30MY5K*Bolt22BACB30MY6K5
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt4BACB30NW6K5X
(c)-Collar12BACC30BH6
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
77 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 78

Group 5-6:
Upper Deck Floor Beam Station (STA) 700
NotesExisting Part NumberNameQTYPart Number /
Specification
(c)-Collar137BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet125BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet10BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D9C or
BACR15BB7D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Group 1-4:
Upper Deck Floor Beam Station (STA) 720
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06827-9 or
65B06827-24 or
65B06827-75 or
65BE0213-3
Upper Chord165B06827-9 or
65B06827-24 or
65B06827-75 or
65BE0213-3
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
78 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 79

Group 1-4:
Upper Deck Floor Beam Station (STA) 720
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06827-3 or
65B06827-34
Reinforcement Angle L/H165B06827-3 or
65B06827-34
(a) (b)65B06827-4 or
65B06827-35
Reinforcement Angle R/H165B06827-4 or
65B06827-35
(a) (b) (g)65BE0213-4Reinforcement Angle165BE0213-4
(c) (d)BACB30MY8K*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt6BACB30MY8K8X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FM5*Bolt8BACB30VT6K3
(c) (d)BACB30FM5*Bolt92BACB30VT6K4
(c) (d)BACB30FM5*Bolt18BACB30VT6K5
(c) (d)BACB30FM5*Bolt2BACB30VT6K6
(c) (d)BACB30FM6*Bolt4BACB30NX6K3X
(c) (d)BACB30FM6*Bolt9BACB30NX6K4X
(c) (d)BACB30FM6*Bolt14BACB30NX6K5X
(c) (d)BACB30FM6*Bolt2BACB30NX6K6X
(c) (d)BACB30FM6*Bolt2BACB30NX6K9X
(c) (d)BACB30MY6K*Bolt8BACB30NX6K5X
(c) (d)BACB30MB6-*Bolt2BACB30NX6K7X
(c) (d)BACB30FN5*Bolt4BACB30NW6K3
(c) (d)BACB30FN6*Bolt6BACB30NW6K4X
(c) (d)BACB30FN6*Bolt8BACB30NW6K5X
(c) (d)BACB30FN6*Bolt42BACB30NW6K6X
(c)-Collar41BACC30BH6
(c)-Collar120BACC30BL6
(c)-Collar62BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BB5D*Rivet142BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet26BACR15BB5D6C or
BACR15BB6D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
79 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 80

Group 1-4:
Upper Deck Floor Beam Station (STA) 720
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet6BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D4C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or
BACR15BB6D*C
(c) (d)MS20426D6Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3B*Rivet4BACR15BA3D5C or
BACR15BA4D*C
(c) (d)BACR15BA3B*Rivet8BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
80 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 81

Group 5-6:
Upper Deck Floor Beam Station (STA) 720
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06827-24 or
65B06827-65 or
65B26467-24
Upper Chord165B06827-24 or
65B06827-65 or
65B26467-24
(a) (b)65B06827-34Reinforcement Angle L/H165B06827-34
(a) (b)65B06827-35Reinforcement Angle R/H165B06827-35
(a) (b) (g)65B06827-68 or
65B26467-22
Reinforcement Angle165B06827-68 or
65B26467-22
(c) (d)BACB30MY5K*Bolt89BACB30MY6K4
(c) (d)BACB30MY5K*Bolt18BACB30MY6K5
(c) (d)BACB30MY6K*Bolt16BACB30NX6K5X
(c) (d)BACB30MB6-*Bolt1BACB30NX6K7X
(c) (d)BACB30MY6K*Bolt4BACB30MY6K6X
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt10BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K5X
(c)-Collar21BACC30BH6
(c)-Collar139BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet136BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet15BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet5BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D9C or
BACR15BB7D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
81 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 82

Group 5-6:
Upper Deck Floor Beam Station (STA) 720
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-101, -23, -37, -41, -5001, -5002, -54, -60, -63, -74, -76, -78, -81, -84, -91, or -97
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06828-58 or
65B06828-70 or
65B06828-71 or
65B06828-72 or
65B06828-82 or
65B06828-98
Upper Chord165B06828-58 or
65B06828-70 or
65B06828-71 or
65B06828-72 or
65B06828-82 or
65B06828-98
(a) (b)65B06828-27 or
65B06828-49
Reinforcement Angle L/H165B06828-27 or
65B06828-49
(a) (b)65B06828-28 or
65B06828-50
Reinforcement Angle R/H165B06828-28 or
65B06828-50
(c) (d)BACB30MY8C*Bolt8BACB30MY8K6X
(c) (d)BACB30MY8C*Bolt8BACB30MY8K7X
(c) (d)BACB30FM5*Bolt9BACB30VT6K3
(c) (d)BACB30FM5*Bolt94BACB30VT6K4
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
82 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 83

Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-101, -23, -37, -41, -5001, -5002, -54, -60, -63, -74, -76, -78, -81, -84, -91, or -97
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30FM5*Bolt27BACB30VT6K5
(c) (d)BACB30FM5*Bolt4BACB30VT6K6
(c) (d)BACB30FM6*Bolt1BACB30NX6K3X
(c) (d)BACB30FM6*Bolt10BACB30NX6K4X
(c) (d)BACB30FM6*Bolt12BACB30NX6K5X
(c) (d)BACB30FM6*Bolt4BACB30NX6K6X
(c) (d)BACB30GP6*Bolt4BACB30NX6K9X
(c) (d)BACB30GP6*Bolt1BACB30NX6K15X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FN6*Bolt8BACB30NW6K4X
(c) (d)BACB30FN6*Bolt14BACB30NW6K5X
(c) (d)BACB30FN6*Bolt18BACB30NW6K6X
(c)-Collar134BACC30BL6
(c)-Collar32BACC30BH6
(c)-Collar42BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet142BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet25BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3B*Rivet10BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA5D*Rivet4BACR15BA5D7C or
BACR15BA6D*C
(c) (d)BACR15CE5D*Rivet2BACR15GF5D5 or
BACR15GF6D*
(c) (d)BACR15CE6D*Rivet4BACR15GF6D5 or
BACR15GF7D*
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
83 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 84

Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-101, -23, -37, -41, -5001, -5002, -54, -60, -63, -74, -76, -78, -81, -84, -91, or -97
NotesExisting Part NumberNameQTYPart Number /
Specification
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-1 or -21
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06828-9Upper Chord165B06828-9
(a) (b)65B06828-3Reinforcement Angle L/H165B06828-3
(a) (b)65B06828-4Reinforcement Angle R/H165B06828-4
(c) (d)BACB30MY8C*Bolt8BACB30MY8K6X
(c) (d)BACB30MY8C*Bolt8BACB30MY8K7X
(c) (d)BACB30FM5*Bolt74BACB30VT6K3
(c) (d)BACB30FM5*Bolt24BACB30VT6K4
(c) (d)BACB30DX5*Bolt3BACB30NX6K3
(c) (d)BACB30FM6*Bolt8BACB30NX6K4X
(c) (d)BACB30FM6*Bolt12BACB30NX6K6X
(c) (d)BACB30FN6*Bolt20BACB30NW6K6X
(c)-Collar98BACC30BL6
(c)-Collar23BACC30BH6
(c)-Collar20BACC30M6
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
84 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 85

Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-1 or -21
NotesExisting Part NumberNameQTYPart Number /
Specification
(c)-Collar16BACC30M8
(c) (d)BACR15BB4D*Rivet152BACR15BB4D4C or
BACR15BB5D*C
(c) (d)BACR15BB4D*Rivet2BACR15BB4D5C or
BACR15BB5D*C
(c) (d)BACR15BB5D*Rivet7BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet27BACR15BB5D6C or
BACR15BB6D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-118 or -123
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06828-119 or
65B06828-124
Upper Chord165B06828-119 or
65B06828-124
(a) (b)65B06828-49Reinforcement Angle L/H165B06828-49
(a) (b)65B06828-50Reinforcement Angle R/H165B06828-50
(c) (d)BACB30MY8K*Bolt8BACB30MY8K6X
(c) (d)BACB30MY8K*Bolt8BACB30MY8K7X
(c) (d)BACB30MY5K*Bolt4BACB30MY6K3
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
85 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 86

Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-118 or -123
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY5K*Bolt90BACB30MY6K4
(c) (d)BACB30MY5K*Bolt23BACB30MY6K5
(c) (d)BACB30MY5K*Bolt4BACB30MY6K6
(c) (d)BACB30MY6K*Bolt2BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt10BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt4BACB30NX6K6X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FN6*Bolt6BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt6BACB30NW6K4X
(c) (d)BACB30FN6*Bolt6BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt6BACB30NW6K5X
(c) (d)BACB30FN6*Bolt12BACB30NW6K6X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K6X
(c) (d)BACB30NW5K*Bolt2BACB30YP6K4
(c)-Collar2BACC30BL6
(c)-Collar16BACC30BH6
(c)-Collar171BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet127BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet24BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3B*Rivet2BACR15BA3D5C or
BACR15BA4D*C
(c) (d)BACR15CE5D*Rivet4BACR15GF4D4 or
BACR15GF5D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
86 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 87

Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-118 or -123
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-104, -117, or -122
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06828-105 or
65B26467-20
Upper Chord165B06828-105 or
65B26467-20
(a) (b) (g)65B06828-107 or
65B26467-29
Reinforcement Angle165B06828-107 or
65B26467-29
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30MY5K*Bolt80BACB30MY6K4
(c) (d)BACB30MY5K*Bolt16BACB30MY6K5
(c) (d)BACB30MY5K*Bolt16BACB30MY6K6
(c) (d)BACB30MY6K*Bolt4BACB30NX6K6X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K4X
(c) (d)BACB30NW6K*Bolt4BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt4BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X
(c)-Collar8BACC30BH6
(c)-Collar138BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet145BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet13BACR15BB5D7C or
BACR15BB6D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
87 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 88

Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-104, -117, or -122
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB6D*Rivet6BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Upper Deck Floor Beam Station (STA) 760 for Groups 1-4, except RD231-RD235
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37122-110 or
65B37122-23 or
65B37122-30 or
65B37122-61 or
65B37122-66 or
65B37122-71 or
65B37122-9 or
65B37122-96
Upper Chord165B37122-110 or
65B37122-23 or
65B37122-30 or
65B37122-61 or
65B37122-66 or
65B37122-71 or
65B37122-9 or
65B37122-96
(a) (b)65B37122-27 or
65B37122-3 or
65B37122-36
Reinforcement Angle L/H165B37122-27 or
65B37122-3 or
65B37122-36
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
88 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 89

Upper Deck Floor Beam Station (STA) 760 for Groups 1-4, except RD231-RD235
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37122-28 or
65B37122-4 or
65B37122-37
Reinforcement Angle R/H165B37122-28 or
65B37122-4 or
65B37122-37
(c) (d)BACB30MY8K*Bolt8BACB30MY8K6X
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30FM5*Bolt4BACB30VT6K3
(c) (d)BACB30FM5*Bolt98BACB30VT6K4
(c) (d)BACB30FM5*Bolt24BACB30VT6K5
(c) (d)BACB30FM5*Bolt6BACB30VT6K6
(c) (d)BACB30FM5*Bolt2BACB30VT6K7
(c) (d)BACB30FM5*Bolt2BACB30VT6K8
(c) (d)BACB30FM6*Bolt4BACB30NX6K3X
(c) (d)BACB30FM6*Bolt5BACB30NX6K5X
(c) (d)BACB30FM6*Bolt10BACB30NX6K6X
(c) (d)BACB30FM6*Bolt14BACB30NX6K7X
(c) (d)BACB30FM6*Bolt2BACB30NX6K13X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K6X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K7X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FN6*Bolt11BACB30NW6K4X
(c) (d)BACB30FN6*Bolt12BACB30NW6K5X
(c) (d)BACB30FN6*Bolt21BACB30NW6K6X
(c)-Collar49BACC30BH6
(c)-Collar136BACC30BL6
(c)-Collar48BACC30M6
(c)-Collar24BACC30M8
(c) (d)BACR15BB5D*Rivet141BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet24BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet9BACR15BB5D7C or
BACR15BB6D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
89 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 90

Upper Deck Floor Beam Station (STA) 760 for Groups 1-4, except RD231-RD235
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet8BACR15BB5D9C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet2BACR15BB6D9C or
BACR15BB7D*C
(c) (d)BACR15BA3B*Rivet8BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA6D*Rivet6BACR15BA6D6C or
BACR15BA7D*C
(c) (d)BACR15BA6D*Rivet3BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15CE6D*Rivet4BACR15GF6D5 or
BACR15GF7D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5-6:
Upper Deck Floor Beam Station (STA) 760
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37122-76 or
65B26467-1
Upper Chord165B37122-76 or
65B26467-1
(a) (b)65B37122-79 or
65B26467-3
Reinforcement Angle L/H165B37122-79 or
65B26467-3
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
90 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 91

Group 5-6:
Upper Deck Floor Beam Station (STA) 760
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37122-80 or
65B26467-4
Reinforcement Angle R/H65B37122-80 or
65B26467-4
(c) (d)BACB30MY8K*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt6BACB30MY8K8X
(c) (d)BACB30MY5K*Bolt78BACB30MY6K4
(c) (d)BACB30MY5K*Bolt18BACB30MY6K5
(c) (d)BACB30MY6K*Bolt4BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt16BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt2BACB30NX6K6X
(c) (d)BACB30NX6K*Bolt6BACB30NX6K3X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K4X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K6X
(c)-Collar34BACC30BL6
(c)-Collar30BACC30BH6
(c)-Collar130BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BB5D*Rivet26BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet113BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet9BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet7BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
91 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 92

Group 5-6:
Upper Deck Floor Beam Station (STA) 760
NotesExisting Part NumberNameQTYPart Number /
Specification
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 760 for RD231-RD235
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37122-96Chord-Upper165B37122-96
(a) (b)65B37122-36Reinforcement Angle L/H165B37122-36
(a) (b)65B37122-37Reinforcement Angle R/H165B37122-37
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30MY5K*Bolt2BACB30MY6K3
(c) (d)BACB30MY5K*Bolt93BACB30MY6K4
(c) (d)BACB30MY5K*Bolt21BACB30MY6K5
(c) (d)BACB30MY6K*Bolt2BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt3BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt4BACB30NX6K6X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K7X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt21BACB30NW6K6X
(c)-Collar21BACC30BH6
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
92 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 93

Upper Deck Floor Beam Station (STA) 760 for RD231-RD235
NotesExisting Part NumberNameQTYPart Number /
Specification
(c)-Collar160BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet120BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet21BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15CE6D*Rivet4BACR15GF6D5 or
BACR15GF7D*
(c) (d)BACR15BA6D*Rivet3BACR15BA6D9C or
BACR15BA7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-1 or -161
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37123-163 or
65B37123-205
Upper Chord165B37123-163 or
65B37123-205
(a) (b)65B37123-53 or
65B37123-206
Reinforcement Angle L/H165B37123-53 or
65B37123-206
(a) (b)65B37123-54 or
65B37123-207
Reinforcement Angle R/H165B37123-54 or
65B37123-207
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
93 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 94

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-1 or -161
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY8C*Bolt8BACB30MY8K6X
(c) (d)BACB30MY8C*Bolt8BACB30MY8K7X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FN6*Bolt8BACB30NW6K4X
(c) (d)BACB30FN6*Bolt6BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt1BACB30NW6K5X
(c) (d)BACB30FN6*Bolt14BACB30NW6K6X
(c) (d)BACB30NW6K*Bolt2BACB30NW6K7X
(c) (d)BACB30FM6*Bolt2BACB30NX6K3X
(c) (d)BACB30FM6*Bolt8BACB30NX6K4X
(c) (d)BACB30FM6*Bolt14BACB30NX6K5X
(c) (d)BACB30MB6*Bolt1BACB30NX6K7X
(c) (d)BACB30MB6*Bolt1BACB30NX6K8X
(c) (d)BACB30FM5*Bolt97BACB30VT6K4
(c) (d)BACB30FM5*Bolt15BACB30VT6K5
(c)-Collar112BACC30BL6
(c)-Collar26BACC30BH6
(c)-Collar33BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BA3B*Rivet4BACR15BA3D5C or
BACR15BA4D*C
(c) (d)BACR15BA3B*Rivet8BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet135BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet22BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D10C
or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet2BACR15BB6D7C or
BACR15BB7D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
94 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 95

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-1 or -161
NotesExisting Part NumberNameQTYPart Number /
Specification
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-108, -116, -119, -130, -138, -145, -186, -188, -5001, -71, -76, -82, or -85
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37123-72 or
65B37123-78 or
65B37123-103 or
65B37123-104 or
65B37123-105 or
65B37123-106 or
65B37123-109
Upper Chord165B37123-72 or
65B37123-78 or
65B37123-103 or
65B37123-104 or
65B37123-105 or
65B37123-106 or
65B37123-109
(a) (b)65B37123-53Reinforcement Angle L/H165B37123-53
(a) (b)65B37123-54Reinforcement Angle R/H165B37123-54
(c) (d)BACB30MY8C*Bolt8BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt8BACB30MY8K8X
(c) (d)BACB30FN5*Bolt8BACB30NW6K4
(c) (d)BACB30FN5*Bolt2BACB30NW6K5
(c) (d)BACB30FN5*Bolt2BACB30NW6K6
(c) (d)BACB30FN6*Bolt9BACB30NW6K3X
(c) (d)BACB30FN6*Bolt11BACB30NW6K4X
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
95 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 96

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-108, -116, -119, -130, -138, -145, -186, -188, -5001, -71, -76, -82, or -85
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30FN6*Bolt13BACB30NW6K5X
(c) (d)BACB30FN6*Bolt5BACB30NW6K6X
(c) (d)BACB30FN6*Bolt6BACB30NW6K7X
(c) (d)BACB30FN6*Bolt17BACB30NW6K8X
(c) (d)BACB30FM6*Bolt2BACB30NX6K4X
(c) (d)BACB30GW6*Bolt2BACB30NX6K5X
(c) (d)BACB30FM6*Bolt11BACB30NX6K5X
(c) (d)BACB30FM6*Bolt6BACB30NX6K6X
(c) (d)BACB30FM6*Bolt12BACB30NX6K7X
(c) (d)BACB30FM5*Bolt2BACB30VT6K4
(c) (d)BACB30FM5*Bolt101BACB30VT6K5
(c) (d)BACB30FM5*Bolt23BACB30VT6K6
(c) (d)BACB30FM5*Bolt8BACB30VT6K7
(c)-Collar134BACC30BL6
(c)-Collar33BACC30BH6
(c)-Collar73BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BA6D*Rivet1BACR15BA6D8C or
BACR15BA7D*C
(c) (d)BACR15BA6D*Rivet1BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D12C
or BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet76BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet16BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet55BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet13BACR15BB6D9C or
BACR15BB7D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
96 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

The text continues at https://openairdocs.org/service-documents/boeing/747-53a2852/file/5f45669c09d2.md?from=97

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.