# Boeing Alert Service Bulletin 747-53A2852: No revision named, from page 73

- Rights: © The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2015-3983; AD 2016-07-03 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Boeing Alert Service Bulletin 747-53A2852](https://openairdocs.org/service-documents/boeing/747-53a2852.md)
- Title as filed: U.S. DOT/FAA - SB-747-53A2852-00
- Pages: 189
- PDF: https://openairdocs.org/files/sha256/5f/45/5f45669c09d2afd8c3b03cedac261fedbc9611f8ef2972ef20448774a7835e0a
- Page: https://openairdocs.org/service-documents/boeing/747-53a2852/file/5f45669c09d2

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 73

Group 1-4:
Upper Deck Floor Beam Station (STA) 680
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY8C*Bolt4BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt12BACB30MY8K8X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FM5*Bolt6BACB30VT6K3
(c) (d)BACB30FM5*Bolt91BACB30VT6K4
(c) (d)BACB30FM5*Bolt19BACB30VT6K5
(c) (d)BACB30FM6*Bolt18BACB30NX6K3X
(c) (d)BACB30FM6*Bolt12BACB30NX6K5X
(c) (d)BACB30FM6*Bolt8BACB30NX6K8X
BACB30FM6*Bolt2BACB30NX6K9X
(c) (d)BACB30FN6*Bolt32BACB30NW6K6X
(c)-Collar40BACC30BH6
(c)-Collar126BACC30BL6
(c)-Collar34BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet144BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet25BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
73 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 74

Group 1-4:
Upper Deck Floor Beam Station (STA) 680
NotesExisting Part NumberNameQTYPart Number /
Specification
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5-6:
Upper Deck Floor Beam Station (STA) 680
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06825-41 or
65B26467-27 or
65B06825-38
Upper Chord165B06825-41 or
65B26467-27 or
65B06825-38
(a) (b)65B06825-3Reinforcement Angle L/H165B06825-3
(a) (b)65B06825-4Reinforcement Angle R/H165B06825-4
(a) (b) (g)65B06825-44 or
65B26467-28
Reinforcement Angle165B06825-44 or
65B26467-28
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K4X
(c) (d)BACB30MY5K*Bolt92BACB30MY6K4
(c) (d)BACB30MY5K*Bolt24BACB30MY6K5
(c) (d)BACB30NW6K*Bolt6BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt4BACB30NW6K5X
(c)-Collar2BACC30BH6
(c)-Collar138BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet145BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet10BACR15BB5D7C or
BACR15BB6D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
74 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 75

Group 5-6:
Upper Deck Floor Beam Station (STA) 680
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet1BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet7BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BA3D*Rivet8BACR15BA3D7C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Group 1-4:
Upper Deck Floor Beam Station (STA) 700
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06826-9 or
65B06826-35 or
65B06826-39 or
65B06826-50 or
65B26467-27 or
65BE0212-3
Upper Chord165B06826-9 or
65B06826-35 or
65B06826-39 or
65B06826-50 or
65B26467-27 or
65BE0212-3
(a) (b)65B06826-3 or
65BE0212-17
Reinforcement Angle L/H165B06826-3 or
65BE0212-17
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
75 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 76

Group 1-4:
Upper Deck Floor Beam Station (STA) 700
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06826-4 or
65BE0212-18
Reinforcement Angle R/H165B06826-4 or
65BE0212-18
(a) (b) (g)65B06826-42 or
65B26467-28
Reinforcement Angle165B06826-42 or
65B26467-28
(c) (d)BACB30MY8C*Bolt4BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt12BACB30MY8K8X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FN6*Bolt24BACB30NW6K6X
(c) (d)BACB30FM5*Bolt6BACB30VT6K3
(c) (d)BACB30FM5*Bolt93BACB30VT6K4
(c) (d)BACB30FM5*Bolt16BACB30VT6K5
(c) (d)BACB30FM6*Bolt10BACB30NX6K3X
(c) (d)BACB30FM6*Bolt12BACB30NX6K5X
(c) (d)BACB30FM6*Bolt2BACB30NX6K9X
(c)-Collar24BACC30BH6
(c)-Collar105BACC30BL6
(c)-Collar26BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet141BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet27BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet3BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BA5D*Rivet1BACR15BA5D6C or
BACR15BA6D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA8D*Rivet2BACR15BA8D10C
or BACR15BA9D*C
(c) (d)BACR15BA3B*Rivet12BACR15BA3D6C or
BACR15BA4*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
76 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 77

Group 1-4:
Upper Deck Floor Beam Station (STA) 700
NotesExisting Part NumberNameQTYPart Number /
Specification
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Group 5-6:
Upper Deck Floor Beam Station (STA) 700
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06826-9 or
65B06826-39 or
65B06826-50 or
65B26467-27
Upper Chord165B06826-9 or
65B06826-39 or
65B06826-50 or
65B26467-27
(a) (b)65B06826-3Reinforcement Angle L/H165B06826-3
(a) (b)65B06826-4Reinforcement Angle R/H165B06826-4
(a) (b) (g)65B06826-42 or
65B26467-28
Reinforcement Angle165B06826-42 or
65B26467-28
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30MY5K*Bolt91BACB30MY6K4
(c) (d)BACB30MY5K*Bolt22BACB30MY6K5
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt4BACB30NW6K5X
(c)-Collar12BACC30BH6
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
77 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 78

Group 5-6:
Upper Deck Floor Beam Station (STA) 700
NotesExisting Part NumberNameQTYPart Number /
Specification
(c)-Collar137BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet125BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet10BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D9C or
BACR15BB7D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Group 1-4:
Upper Deck Floor Beam Station (STA) 720
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06827-9 or
65B06827-24 or
65B06827-75 or
65BE0213-3
Upper Chord165B06827-9 or
65B06827-24 or
65B06827-75 or
65BE0213-3
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
78 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 79

Group 1-4:
Upper Deck Floor Beam Station (STA) 720
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06827-3 or
65B06827-34
Reinforcement Angle L/H165B06827-3 or
65B06827-34
(a) (b)65B06827-4 or
65B06827-35
Reinforcement Angle R/H165B06827-4 or
65B06827-35
(a) (b) (g)65BE0213-4Reinforcement Angle165BE0213-4
(c) (d)BACB30MY8K*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt6BACB30MY8K8X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FM5*Bolt8BACB30VT6K3
(c) (d)BACB30FM5*Bolt92BACB30VT6K4
(c) (d)BACB30FM5*Bolt18BACB30VT6K5
(c) (d)BACB30FM5*Bolt2BACB30VT6K6
(c) (d)BACB30FM6*Bolt4BACB30NX6K3X
(c) (d)BACB30FM6*Bolt9BACB30NX6K4X
(c) (d)BACB30FM6*Bolt14BACB30NX6K5X
(c) (d)BACB30FM6*Bolt2BACB30NX6K6X
(c) (d)BACB30FM6*Bolt2BACB30NX6K9X
(c) (d)BACB30MY6K*Bolt8BACB30NX6K5X
(c) (d)BACB30MB6-*Bolt2BACB30NX6K7X
(c) (d)BACB30FN5*Bolt4BACB30NW6K3
(c) (d)BACB30FN6*Bolt6BACB30NW6K4X
(c) (d)BACB30FN6*Bolt8BACB30NW6K5X
(c) (d)BACB30FN6*Bolt42BACB30NW6K6X
(c)-Collar41BACC30BH6
(c)-Collar120BACC30BL6
(c)-Collar62BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BB5D*Rivet142BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet26BACR15BB5D6C or
BACR15BB6D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
79 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 80

Group 1-4:
Upper Deck Floor Beam Station (STA) 720
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet6BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D4C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or
BACR15BB6D*C
(c) (d)MS20426D6Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3B*Rivet4BACR15BA3D5C or
BACR15BA4D*C
(c) (d)BACR15BA3B*Rivet8BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
80 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 81

Group 5-6:
Upper Deck Floor Beam Station (STA) 720
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06827-24 or
65B06827-65 or
65B26467-24
Upper Chord165B06827-24 or
65B06827-65 or
65B26467-24
(a) (b)65B06827-34Reinforcement Angle L/H165B06827-34
(a) (b)65B06827-35Reinforcement Angle R/H165B06827-35
(a) (b) (g)65B06827-68 or
65B26467-22
Reinforcement Angle165B06827-68 or
65B26467-22
(c) (d)BACB30MY5K*Bolt89BACB30MY6K4
(c) (d)BACB30MY5K*Bolt18BACB30MY6K5
(c) (d)BACB30MY6K*Bolt16BACB30NX6K5X
(c) (d)BACB30MB6-*Bolt1BACB30NX6K7X
(c) (d)BACB30MY6K*Bolt4BACB30MY6K6X
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt10BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K5X
(c)-Collar21BACC30BH6
(c)-Collar139BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet136BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet15BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet5BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D9C or
BACR15BB7D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
81 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 82

Group 5-6:
Upper Deck Floor Beam Station (STA) 720
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-101, -23, -37, -41, -5001, -5002, -54, -60, -63, -74, -76, -78, -81, -84, -91, or -97
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06828-58 or
65B06828-70 or
65B06828-71 or
65B06828-72 or
65B06828-82 or
65B06828-98
Upper Chord165B06828-58 or
65B06828-70 or
65B06828-71 or
65B06828-72 or
65B06828-82 or
65B06828-98
(a) (b)65B06828-27 or
65B06828-49
Reinforcement Angle L/H165B06828-27 or
65B06828-49
(a) (b)65B06828-28 or
65B06828-50
Reinforcement Angle R/H165B06828-28 or
65B06828-50
(c) (d)BACB30MY8C*Bolt8BACB30MY8K6X
(c) (d)BACB30MY8C*Bolt8BACB30MY8K7X
(c) (d)BACB30FM5*Bolt9BACB30VT6K3
(c) (d)BACB30FM5*Bolt94BACB30VT6K4
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
82 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 83

Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-101, -23, -37, -41, -5001, -5002, -54, -60, -63, -74, -76, -78, -81, -84, -91, or -97
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30FM5*Bolt27BACB30VT6K5
(c) (d)BACB30FM5*Bolt4BACB30VT6K6
(c) (d)BACB30FM6*Bolt1BACB30NX6K3X
(c) (d)BACB30FM6*Bolt10BACB30NX6K4X
(c) (d)BACB30FM6*Bolt12BACB30NX6K5X
(c) (d)BACB30FM6*Bolt4BACB30NX6K6X
(c) (d)BACB30GP6*Bolt4BACB30NX6K9X
(c) (d)BACB30GP6*Bolt1BACB30NX6K15X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FN6*Bolt8BACB30NW6K4X
(c) (d)BACB30FN6*Bolt14BACB30NW6K5X
(c) (d)BACB30FN6*Bolt18BACB30NW6K6X
(c)-Collar134BACC30BL6
(c)-Collar32BACC30BH6
(c)-Collar42BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet142BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet25BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3B*Rivet10BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA5D*Rivet4BACR15BA5D7C or
BACR15BA6D*C
(c) (d)BACR15CE5D*Rivet2BACR15GF5D5 or
BACR15GF6D*
(c) (d)BACR15CE6D*Rivet4BACR15GF6D5 or
BACR15GF7D*
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
83 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 84

Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-101, -23, -37, -41, -5001, -5002, -54, -60, -63, -74, -76, -78, -81, -84, -91, or -97
NotesExisting Part NumberNameQTYPart Number /
Specification
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-1 or -21
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06828-9Upper Chord165B06828-9
(a) (b)65B06828-3Reinforcement Angle L/H165B06828-3
(a) (b)65B06828-4Reinforcement Angle R/H165B06828-4
(c) (d)BACB30MY8C*Bolt8BACB30MY8K6X
(c) (d)BACB30MY8C*Bolt8BACB30MY8K7X
(c) (d)BACB30FM5*Bolt74BACB30VT6K3
(c) (d)BACB30FM5*Bolt24BACB30VT6K4
(c) (d)BACB30DX5*Bolt3BACB30NX6K3
(c) (d)BACB30FM6*Bolt8BACB30NX6K4X
(c) (d)BACB30FM6*Bolt12BACB30NX6K6X
(c) (d)BACB30FN6*Bolt20BACB30NW6K6X
(c)-Collar98BACC30BL6
(c)-Collar23BACC30BH6
(c)-Collar20BACC30M6
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
84 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 85

Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-1 or -21
NotesExisting Part NumberNameQTYPart Number /
Specification
(c)-Collar16BACC30M8
(c) (d)BACR15BB4D*Rivet152BACR15BB4D4C or
BACR15BB5D*C
(c) (d)BACR15BB4D*Rivet2BACR15BB4D5C or
BACR15BB5D*C
(c) (d)BACR15BB5D*Rivet7BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet27BACR15BB5D6C or
BACR15BB6D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-118 or -123
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06828-119 or
65B06828-124
Upper Chord165B06828-119 or
65B06828-124
(a) (b)65B06828-49Reinforcement Angle L/H165B06828-49
(a) (b)65B06828-50Reinforcement Angle R/H165B06828-50
(c) (d)BACB30MY8K*Bolt8BACB30MY8K6X
(c) (d)BACB30MY8K*Bolt8BACB30MY8K7X
(c) (d)BACB30MY5K*Bolt4BACB30MY6K3
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
85 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 86

Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-118 or -123
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY5K*Bolt90BACB30MY6K4
(c) (d)BACB30MY5K*Bolt23BACB30MY6K5
(c) (d)BACB30MY5K*Bolt4BACB30MY6K6
(c) (d)BACB30MY6K*Bolt2BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt10BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt4BACB30NX6K6X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FN6*Bolt6BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt6BACB30NW6K4X
(c) (d)BACB30FN6*Bolt6BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt6BACB30NW6K5X
(c) (d)BACB30FN6*Bolt12BACB30NW6K6X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K6X
(c) (d)BACB30NW5K*Bolt2BACB30YP6K4
(c)-Collar2BACC30BL6
(c)-Collar16BACC30BH6
(c)-Collar171BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet127BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet24BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3B*Rivet2BACR15BA3D5C or
BACR15BA4D*C
(c) (d)BACR15CE5D*Rivet4BACR15GF4D4 or
BACR15GF5D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
86 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 87

Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-118 or -123
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-104, -117, or -122
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B06828-105 or
65B26467-20
Upper Chord165B06828-105 or
65B26467-20
(a) (b) (g)65B06828-107 or
65B26467-29
Reinforcement Angle165B06828-107 or
65B26467-29
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30MY5K*Bolt80BACB30MY6K4
(c) (d)BACB30MY5K*Bolt16BACB30MY6K5
(c) (d)BACB30MY5K*Bolt16BACB30MY6K6
(c) (d)BACB30MY6K*Bolt4BACB30NX6K6X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K4X
(c) (d)BACB30NW6K*Bolt4BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt4BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X
(c)-Collar8BACC30BH6
(c)-Collar138BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet145BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet13BACR15BB5D7C or
BACR15BB6D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
87 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 88

Upper Deck Floor Beam Station (STA) 740 on airplanes that use one of the following drawing installations:
65B06828-104, -117, or -122
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB6D*Rivet6BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
(g) Some airplanes have a full length reinforcement angle. Refer to APPENDIX A for effectivity.
Upper Deck Floor Beam Station (STA) 760 for Groups 1-4, except RD231-RD235
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37122-110 or
65B37122-23 or
65B37122-30 or
65B37122-61 or
65B37122-66 or
65B37122-71 or
65B37122-9 or
65B37122-96
Upper Chord165B37122-110 or
65B37122-23 or
65B37122-30 or
65B37122-61 or
65B37122-66 or
65B37122-71 or
65B37122-9 or
65B37122-96
(a) (b)65B37122-27 or
65B37122-3 or
65B37122-36
Reinforcement Angle L/H165B37122-27 or
65B37122-3 or
65B37122-36
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
88 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 89

Upper Deck Floor Beam Station (STA) 760 for Groups 1-4, except RD231-RD235
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37122-28 or
65B37122-4 or
65B37122-37
Reinforcement Angle R/H165B37122-28 or
65B37122-4 or
65B37122-37
(c) (d)BACB30MY8K*Bolt8BACB30MY8K6X
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30FM5*Bolt4BACB30VT6K3
(c) (d)BACB30FM5*Bolt98BACB30VT6K4
(c) (d)BACB30FM5*Bolt24BACB30VT6K5
(c) (d)BACB30FM5*Bolt6BACB30VT6K6
(c) (d)BACB30FM5*Bolt2BACB30VT6K7
(c) (d)BACB30FM5*Bolt2BACB30VT6K8
(c) (d)BACB30FM6*Bolt4BACB30NX6K3X
(c) (d)BACB30FM6*Bolt5BACB30NX6K5X
(c) (d)BACB30FM6*Bolt10BACB30NX6K6X
(c) (d)BACB30FM6*Bolt14BACB30NX6K7X
(c) (d)BACB30FM6*Bolt2BACB30NX6K13X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K6X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K7X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FN6*Bolt11BACB30NW6K4X
(c) (d)BACB30FN6*Bolt12BACB30NW6K5X
(c) (d)BACB30FN6*Bolt21BACB30NW6K6X
(c)-Collar49BACC30BH6
(c)-Collar136BACC30BL6
(c)-Collar48BACC30M6
(c)-Collar24BACC30M8
(c) (d)BACR15BB5D*Rivet141BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet24BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet9BACR15BB5D7C or
BACR15BB6D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
89 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 90

Upper Deck Floor Beam Station (STA) 760 for Groups 1-4, except RD231-RD235
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet8BACR15BB5D9C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet2BACR15BB6D9C or
BACR15BB7D*C
(c) (d)BACR15BA3B*Rivet8BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA6D*Rivet6BACR15BA6D6C or
BACR15BA7D*C
(c) (d)BACR15BA6D*Rivet3BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15CE6D*Rivet4BACR15GF6D5 or
BACR15GF7D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5-6:
Upper Deck Floor Beam Station (STA) 760
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37122-76 or
65B26467-1
Upper Chord165B37122-76 or
65B26467-1
(a) (b)65B37122-79 or
65B26467-3
Reinforcement Angle L/H165B37122-79 or
65B26467-3
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
90 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 91

Group 5-6:
Upper Deck Floor Beam Station (STA) 760
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37122-80 or
65B26467-4
Reinforcement Angle R/H65B37122-80 or
65B26467-4
(c) (d)BACB30MY8K*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt6BACB30MY8K8X
(c) (d)BACB30MY5K*Bolt78BACB30MY6K4
(c) (d)BACB30MY5K*Bolt18BACB30MY6K5
(c) (d)BACB30MY6K*Bolt4BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt16BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt2BACB30NX6K6X
(c) (d)BACB30NX6K*Bolt6BACB30NX6K3X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K4X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K6X
(c)-Collar34BACC30BL6
(c)-Collar30BACC30BH6
(c)-Collar130BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BB5D*Rivet26BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet113BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet9BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet7BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
91 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 92

Group 5-6:
Upper Deck Floor Beam Station (STA) 760
NotesExisting Part NumberNameQTYPart Number /
Specification
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 760 for RD231-RD235
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37122-96Chord-Upper165B37122-96
(a) (b)65B37122-36Reinforcement Angle L/H165B37122-36
(a) (b)65B37122-37Reinforcement Angle R/H165B37122-37
(c) (d)BACB30MY8K*Bolt16BACB30MY8K7X
(c) (d)BACB30MY5K*Bolt2BACB30MY6K3
(c) (d)BACB30MY5K*Bolt93BACB30MY6K4
(c) (d)BACB30MY5K*Bolt21BACB30MY6K5
(c) (d)BACB30MY6K*Bolt2BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt3BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt4BACB30NX6K6X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K7X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt21BACB30NW6K6X
(c)-Collar21BACC30BH6
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
92 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 93

Upper Deck Floor Beam Station (STA) 760 for RD231-RD235
NotesExisting Part NumberNameQTYPart Number /
Specification
(c)-Collar160BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet120BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet21BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15CE6D*Rivet4BACR15GF6D5 or
BACR15GF7D*
(c) (d)BACR15BA6D*Rivet3BACR15BA6D9C or
BACR15BA7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-1 or -161
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37123-163 or
65B37123-205
Upper Chord165B37123-163 or
65B37123-205
(a) (b)65B37123-53 or
65B37123-206
Reinforcement Angle L/H165B37123-53 or
65B37123-206
(a) (b)65B37123-54 or
65B37123-207
Reinforcement Angle R/H165B37123-54 or
65B37123-207
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
93 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 94

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-1 or -161
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY8C*Bolt8BACB30MY8K6X
(c) (d)BACB30MY8C*Bolt8BACB30MY8K7X
(c) (d)BACB30FN5*Bolt2BACB30NW6K4
(c) (d)BACB30FN6*Bolt8BACB30NW6K4X
(c) (d)BACB30FN6*Bolt6BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt1BACB30NW6K5X
(c) (d)BACB30FN6*Bolt14BACB30NW6K6X
(c) (d)BACB30NW6K*Bolt2BACB30NW6K7X
(c) (d)BACB30FM6*Bolt2BACB30NX6K3X
(c) (d)BACB30FM6*Bolt8BACB30NX6K4X
(c) (d)BACB30FM6*Bolt14BACB30NX6K5X
(c) (d)BACB30MB6*Bolt1BACB30NX6K7X
(c) (d)BACB30MB6*Bolt1BACB30NX6K8X
(c) (d)BACB30FM5*Bolt97BACB30VT6K4
(c) (d)BACB30FM5*Bolt15BACB30VT6K5
(c)-Collar112BACC30BL6
(c)-Collar26BACC30BH6
(c)-Collar33BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BA3B*Rivet4BACR15BA3D5C or
BACR15BA4D*C
(c) (d)BACR15BA3B*Rivet8BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet135BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet22BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D10C
or BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet2BACR15BB6D7C or
BACR15BB7D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
94 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 95

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-1 or -161
NotesExisting Part NumberNameQTYPart Number /
Specification
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-108, -116, -119, -130, -138, -145, -186, -188, -5001, -71, -76, -82, or -85
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37123-72 or
65B37123-78 or
65B37123-103 or
65B37123-104 or
65B37123-105 or
65B37123-106 or
65B37123-109
Upper Chord165B37123-72 or
65B37123-78 or
65B37123-103 or
65B37123-104 or
65B37123-105 or
65B37123-106 or
65B37123-109
(a) (b)65B37123-53Reinforcement Angle L/H165B37123-53
(a) (b)65B37123-54Reinforcement Angle R/H165B37123-54
(c) (d)BACB30MY8C*Bolt8BACB30MY8K7X
(c) (d)BACB30MY8C*Bolt8BACB30MY8K8X
(c) (d)BACB30FN5*Bolt8BACB30NW6K4
(c) (d)BACB30FN5*Bolt2BACB30NW6K5
(c) (d)BACB30FN5*Bolt2BACB30NW6K6
(c) (d)BACB30FN6*Bolt9BACB30NW6K3X
(c) (d)BACB30FN6*Bolt11BACB30NW6K4X
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
95 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 96

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-108, -116, -119, -130, -138, -145, -186, -188, -5001, -71, -76, -82, or -85
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30FN6*Bolt13BACB30NW6K5X
(c) (d)BACB30FN6*Bolt5BACB30NW6K6X
(c) (d)BACB30FN6*Bolt6BACB30NW6K7X
(c) (d)BACB30FN6*Bolt17BACB30NW6K8X
(c) (d)BACB30FM6*Bolt2BACB30NX6K4X
(c) (d)BACB30GW6*Bolt2BACB30NX6K5X
(c) (d)BACB30FM6*Bolt11BACB30NX6K5X
(c) (d)BACB30FM6*Bolt6BACB30NX6K6X
(c) (d)BACB30FM6*Bolt12BACB30NX6K7X
(c) (d)BACB30FM5*Bolt2BACB30VT6K4
(c) (d)BACB30FM5*Bolt101BACB30VT6K5
(c) (d)BACB30FM5*Bolt23BACB30VT6K6
(c) (d)BACB30FM5*Bolt8BACB30VT6K7
(c)-Collar134BACC30BL6
(c)-Collar33BACC30BH6
(c)-Collar73BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BA6D*Rivet1BACR15BA6D8C or
BACR15BA7D*C
(c) (d)BACR15BA6D*Rivet1BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D12C
or BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet76BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet16BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet55BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet13BACR15BB6D9C or
BACR15BB7D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
96 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 97

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-108, -116, -119, -130, -138, -145, -186, -188, -5001, -71, -76, -82, or -85
NotesExisting Part NumberNameQTYPart Number /
Specification
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-120, -125, -148, -25, -60, or -65
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37123-26 or
65B37123-101 or
65B37123-104 or
65B37123-127 or
65B37123-604
Upper Chord165B37123-26 or
65B37123-101 or
65B37123-104 or
65B37123-127 or
65B37123-604
(a) (b)65B37123-29Reinforcement Angle L/H165B37123-29
(a) (b)65B37123-30Reinforcement Angle R/H165B37123-30
(c) (d)BACB30MY6C*Bolt2BACB30MY6K6X
(c) (d)BACB30MY8C*Bolt8BACB30MY8K6X
(c) (d)BACB30MY8C*Bolt8BACB30MY8K8X
(c) (d)BACB30FN6*Bolt13BACB30NW6K3X
(c) (d)BACB30FN6*Bolt14BACB30NW6K4X
(c) (d)BACB30FN5*Bolt12BACB30NW6K5
(c) (d)BACB30FN6*Bolt46BACB30NW6K5X
(c) (d)BACB30FN6*Bolt8BACB30NW6K6X
(c) (d)BACB30FN6*Bolt3BACB30NW6K7X
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
97 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 98

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-120, -125, -148, -25, -60, or -65
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30FM6*Bolt6BACB30NX6K5X
(c) (d)BACB30FM6*Bolt8BACB30NX6K6X
(c) (d)BACB30FM6*Bolt12BACB30NX6K7X
(c) (d)BACB30FM6*Bolt2BACB30NX6K9X
(c) (d)BACB30FM6*Bolt2BACB30NX6K13X
(c) (d)BACB30FM5*Bolt69BACB30VT6K5
(c) (d)BACB30FM5*Bolt35BACB30VT6K6
(c) (d)BACB30FM5*Bolt2BACB30VT6K57
(c)-Collar106BACC30BL6
(c)-Collar30BACC30BH6
(c)-Collar98BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BB5D*Rivet73BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet21BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet52BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet8BACR15BB6D9C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D10C
or BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
98 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 99

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-120, -125, -148, -25, -60, or -65
NotesExisting Part NumberNameQTYPart Number /
Specification
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-147
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37123-150Upper Chord165B37123-150
(a) (b)65B37123-53Reinforcement Angle L/H165B37123-53
(a) (b)65B37123-54Reinforcement Angle R/H165B37123-54
(c) (d)BACB30MYC6*Bolt8BACB30MY8K6X
(c) (d)BACB30MYC6*Bolt8BACB30MY8K8X
(c) (d)BACB30FN5*Bolt2BACB30NW6K5
(c) (d)BACB30FN6*Bolt33BACB30NW6K5X
(c) (d)BACB30FN5*Bolt2BACB30NW6K6
(c) (d)BACB30FN6*Bolt2BACB30NW6K7X
(c) (d)BACB30FM6*Bolt2BACB30NX6K4X
(c) (d)BACB30FM6*Bolt4BACB30NX6K5X
(c) (d)BACB30GW6*Bolt1BACB30NX6K5X
(c) (d)BACB30FM6*Bolt4BACB30NX6K6X
(c) (d)BACB30FM6*Bolt10BACB30NX6K7X
(c) (d)BACB30FN5*Bolt103BACB30VT6K5
(c) (d)BACB30FN5*Bolt17BACB30VT6K6
(c) (d)BACB30FN5*Bolt8BACB30VT6K7
(c)-Collar130BACC30BL6
(c)-Collar21BACC30BH6
(c)-Collar39BACC30M6
(c)-Collar16BACC30M8
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
99 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 100

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-147
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet76BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet10BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet52BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet7BACR15BB6D9C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-180, -184, -185, -189, -190, or -195
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37123-167 or
65B26467-1
Upper Chord165B37123-167 or
65B26467-1
(a) (b)65B37123-170 or
65B26467-3
Reinforcement Angle L/H165B37123-170 or
65B26467-3
(a) (b)65B37123-171 or
65B26467-4
Reinforcement Angle R/H165B37123-171 or
65B26467-4
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
100 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 101

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-180, -184, -185, -189, -190, or -195
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY8C* or
BACB30MY8K*
Bolt14BACB30MY8K7X
(c) (d)BACB30MY8C* or
BACB30MY8K*
Bolt6BACB30MY8K8X
(c) (d)BACB30MY6K*Bolt78BACB30MY6K4
(c) (d)BACB30MY6K*Bolt18BACB30MY6K5
(c) (d)BACB30MY6K*Bolt4BACB30MY6K6
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt15BACB30NW6K6X
(c) (d)BACB30NW6K*Bolt2BACB30NW6K7X
(c) (d)BACB30MY6K*Bolt6BACB30NX6K3X
(c) (d)BACB30NX6K*Bolt6BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt2BACB30NX6K4X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt16BACB30NX6K5X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K8X
(c)-Collar34BACC30BH6
(c)-Collar150BACC30M6
(c)-Collar20BACC30M8
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet136BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet14BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet7BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D8C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
101 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 102

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-180, -184, -185, -189, -190, or -195
NotesExisting Part NumberNameQTYPart Number /
Specification
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-192
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B37123-105Upper Chord165B37123-105
(a) (b)65B37123-53Reinforcement Angle L/H165B37123-53
(a) (b)65B37123-54Reinforcement Angle R/H165B37123-54
(c) (d)BACB30MY5K*Bolt94BACB30MY6K5
(c) (d)BACB30MY5K*Bolt20BACB30MY6K6
(c) (d)BACB30MY5K*Bolt8BACB30MY6K7
(c) (d)BACB30MY8K*Bolt8BACB30MY8K8X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K3X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt7BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt7BACB30NW6K7X
(c) (d)BACB30NW6K*Bolt16BACB30NW6K8X
(c) (d)BACB30NW8K*Bolt8BACB30NW8K7X
(c) (d)BACB30MY6K*Bolt6BACB30NX6K6X
(c) (d)BACB30MY6K*Bolt8BACB30NX6K7X
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
102 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 103

Upper Deck Floor Beam Station (STA) 780 on airplanes that use one of the following drawing installations:
65B37123-192
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30NW5K*Bolt4BACB30YP6K4
(c) (d)BACB30NW5K*Bolt2BACB30YP6K5
(c)-Collar6BACC30BL6
(c)-Collar14BACC30BH6
(c)-Collar168BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet76BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet12BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet62BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet11BACR15BB6D9C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
103 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 104

Group 5-6:
Upper Deck Floor Beam Station (STA) 800
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B25634-3 or
65B26467-1
Upper Chord165B25634-3 or
65B26467-1
(a) (b)65B25634-6 or
65B26467-9
Reinforcement Angle L/H165B25634-6 or
65B26467-9
(a) (b)65B25634-7 or
65B26467-4
Reinforcement Angle R/H165B25634-7 or
65B26467-4
(c) (d)BACB30NX6K*Bolt8BACB30NX6K4X
(c) (d)BACB30MY5K*Bolt7BACB30MY6K3
(c) (d)BACB30MY5K*Bolt77BACB30MY6K4
(c) (d)BACB30MY5K*Bolt18BACB30MY6K5
(c) (d)BACB30MY5K*Bolt2BACB30MY6K6
(c) (d)BACB30MY8K*Bolt8BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt2BACB30MY8K8X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X
(c) (d)BACB30MY6K*Bolt4BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt18BACB30NX6K5X
(c) (d)BACB30NX8K*Bolt8BACB30NX8K10X
(c) (d)BACB30NX8K*Bolt4BACB30NX8K11X
(c)-Collar30BACC30BH6
(c)-Collar12BACC30BH8
(c)-Collar140BACC30M6
(c)-Collar10BACC30M8
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet19BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet116BACR15BB5D6C or
BACR15BB6D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
104 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 105

Group 5-6:
Upper Deck Floor Beam Station (STA) 800
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR30BB5D*Rivet10BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet7BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet3BACR15BB6D8C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5-6:
Upper Deck Floor Beam Station (STA) 820
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B25635-3 or
65B26467-1 or
65B26467-57
Upper Chord165B25635-3 or
65B26467-1 or
65B26467-57
(a) (b)65B25635-6 or
65B26467-3
Reinforcement Angle L/H165B25635-6 or
65B26467-3
(a) (b)65B25635-7 or
65B26467-4
Reinforcement Angle R/H165B25635-7 or
65B26467-4
(c) (d)BACB30MY5K*Bolt78BACB30MY6K4
(c) (d)BACB30MY5K*Bolt16BACB30MY6K5
(c) (d)BACB30MY8K*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
105 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 106

Group 5-6:
Upper Deck Floor Beam Station (STA) 820
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X
(c) (d)BACB30NW8K*Bolt2BACB30NW8K8X
(c) (d)BACB30NX6K*Bolt6BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt4BACB30NX6K4X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt18BACB30NX6K5X
(c)-Collar30BACC30BH6
(c)-Collar128BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet26BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet114BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet9BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet8BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D8C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
106 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 107

Group 5-6:
Upper Deck Floor Beam Station (STA) 820
NotesExisting Part NumberNameQTYPart Number /
Specification
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5-6:
Upper Deck Floor Beam Station (STA) 840
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B25636-3Upper Chord165B25636-3
(a) (b)65B25636-6Reinforcement Angle L/H165B25636-6
(a) (b)65B25636-7Reinforcement Angle R/H165B25636-7
(c) (d)BACB30MY5K*Bolt78BACB30MY6K4
(c) (d)BACB30MY5K*Bolt16BACB30MY6K5
(c) (d)BACB30MY8K*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X
(c) (d)BACB30NW8K*Bolt2BACB30NW8K8X
(c) (d)BACB30MY6K*Bolt8BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c)-Collar20BACC30BH6
(c)-Collar128BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet146BACR15BB5D5C or
BACR15BB6D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
107 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 108

Group 5-6:
Upper Deck Floor Beam Station (STA) 840
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet18BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet10BACR15BB6D7C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 6:
Upper Deck Floor Beam Station (STA) 860
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B25637-3 or
65B25637-38
Upper Chord165B25637-3 or
65B25637-38
(a) (b)65B25637-10Failsafe Strap165B25637-10
(a) (b)65B25637-23Reinforcement Angle L/H165B25637-23
(a) (b)65B25637-24Reinforcement Angle R/H165B25637-24
(c) (d)BACB30MY8K*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
(c) (d)BACB30MY6K*Bolt90BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt16BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt6BACB30NX6K6X
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
108 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 109

Group 6:
Upper Deck Floor Beam Station (STA) 860
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY6K*Bolt156BACB30NX6K7X
(c) (d)BACB30NX8K*Bolt14BACB30NX8K11X
(c)-Collar226BACC30BH6
(c)-Collar2BACC30BH8
(c)-Collar16BACC30M8
(c) (d)BACR15BB6D*Rivet156BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet14BACR15BB6D7C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 1000
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B25644-3 or
65B26469-1
Upper Chord165B25644-3 or
65B26469-1
(a) (b)65B25644-6 or
65B26469-3
Reinforcement Angle L/H165B25644-6 or
65B26469-3
(a) (b)65B25644-7 or
65B26469-4
Reinforcement Angle R/H165B25644-7 or
65B26469-4
(c) (d)BACB30MY5K*Bolt86BACB30MY6K4
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
109 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 110

Group 5:
Upper Deck Floor Beam Station (STA) 1000
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY5K*Bolt17BACB30MY6K5
(c) (d)BACB30MY5K*Bolt2BACB30MY6K6
(c) (d)BACB30MY8K*Bolt6BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt6BACB30MY8K9X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K10X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt20BACB30NW6K6X
(c) (d)BACB30NW6K*Bolt1BACB30NW6K7X
(c) (d)BACB30NX6K*Bolt7BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt5BACB30NX6K4X
(c) (d)BACB30NX6K*Bolt9BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt14BACB30NX6K5X
(c)-Collar35BACC30BH6
(c)-Collar150BACC30M6
(c)-Collar16BACC30M8
(c) (d)BACR15BA3D*Rivet4BACR15BA3D4C or
BACR15BA4D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BA4D*Rivet2BACR15BA4D4C or
BACR15BA5D*C
(c) (d)BACR15BA6D*Rivet2BACR15BA6D9C or
BACR15BA7D*C
(c) (d)BACR15BB5D*Rivet29BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet113BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet10BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet2BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet6BACR15BB6D7C or
BACR15BB7D*C
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
110 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 111

Group 5:
Upper Deck Floor Beam Station (STA) 1000
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB6D*Rivet2BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15CE5D*Rivet1BACR15GF5D5 or
BACR15GF6D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 1020
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B25645-3 or
65B26469-9 or
65B26469-30 or
65B26469-33
Upper Chord165B25645-3 or
65B26469-9 or
65B26469-30 or
65B26469-33
(a) (b)65B25645-4 or
65B26469-5
Reinforcement Angle L/H165B25645-4 or
65B26469-5
(a) (b)65B25645-5 or
65B26469-6 or
65B26469-31
Reinforcement Angle R/H165B25645-5 or
65B26469-6 or
65B26469-31
(c) (d)BACB30MY5K*Bolt82BACB30MY6K4
(c) (d)BACB30MY5K*Bolt15BACB30MY6K5
(c) (d)BACB30MY8K*Bolt14BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
111 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 112

Group 5:
Upper Deck Floor Beam Station (STA) 1020
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30NW6K*Bolt10BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt14BACB30NW6K6X
(c) (d)BACB30MY6K*Bolt1BACB30NX6K3X
(c) (d)BACB30NX6K*Bolt5BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt6BACB30NX6K4X
(c) (d)BACB30NX6K*Bolt6BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c)-Collar30BACC30BH6
(c)-Collar132BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BA3D*Rivet4BACR15BA3D4C or
BACR15BA4D*C
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BB5D*Rivet137BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet16BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet1BACR15BB5D8C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet2BACR15BB6DC or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet10BACR15BB6D6C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet1BACR15BB6D8C or
BACR15BB7D*C
(c) (d)BACR15CE3D*Rivet4BACR15GF3D5 or
BACR15GF4D*
(c) (d)BACR15CE4D*Rivet2BACR15GF4D5 or
BACR15GF5D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
112 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 113

Group 5:
Upper Deck Floor Beam Station (STA) 1020
NotesExisting Part NumberNameQTYPart Number /
Specification
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 1040
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B25646-3 or
65B26469-24
Upper Chord165B25646-3 or
65B26469-24
(a) (b)65B25646-4 or
65B26469-25
Reinforcement Angle L/H165B25646-4 or
65B26469-25
(a) (b)65B25646-5 or
65B26469-26
Reinforcement Angle R/H165B25646-5 or
65B26469-26
(c) (d)BACB30MY5K*Bolt80BACB30MY6K4
(c) (d)BACB30MY5K*Bolt15BACB30MY6K5
(c) (d)BACB30MY8K*Bolt14BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt16BACB30NW6K6X
(c) (d)BACB30NX6K*Bolt7BACB30NX6K3X
(c) (d)BACB30MY6K*Bolt4BACB30NX6K4X
(c) (d)BACB30NX6K*Bolt4BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt12BACB30NX6K5X
(c)-Collar27BACC30BH6
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
113 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 114

Group 5:
Upper Deck Floor Beam Station (STA) 1040
NotesExisting Part NumberNameQTYPart Number /
Specification
(c)-Collar131BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BA3D*Rivet4BACR15BA3D6C or
BACR15BA4D*C
(c) (d)BACR15BB5D*Rivet27BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet117BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet12BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet7BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15CE5D*Rivet2BACR15GF5D7 or
BACR15GF6D*
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 1060
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B25647-2 or
65B26469-11
Upper Chord165B25647-2 or
65B26469-11
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
114 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 115

Group 5:
Upper Deck Floor Beam Station (STA) 1060
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B25647-7 or
65B26469-7
Reinforcement Angle L/H165B25647-7 or
65B26469-7
(a) (b)65B25647-8 or
65B26469-8
Reinforcement Angle R/H165B25647-8 or
65B26469-8
(c) (d)BACB30MY5K*Bolt95BACB30MY6K4
(c) (d)BACB30MY5K*Bolt16BACB30MY6K5
(c) (d)BACB30MY8K*Bolt2BACB30MY8K6X
(c) (d)BACB30MY8K*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
(c) (d)BACB30NW6K*Bolt4BACB30NW6K3X
(c) (d)BACB30NW6K*Bolt6BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt16BACB30NW6K5X
(c) (d)BACB30MY6K*Bolt3BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt18BACB30NX6K5X
(c)-Collar21BACC30BH6
(c)-Collar137BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BB5D*Rivet93BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet61BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet7BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet5BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D8C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
115 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 116

Group 5:
Upper Deck Floor Beam Station (STA) 1060
NotesExisting Part NumberNameQTYPart Number /
Specification
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 1080
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B25648-2 or
65B26469-13
Upper Chord165B25648-2 or
65B26469-13
(a) (b)65B25648-7 or
65B26469-15
Reinforcement Angle L/H165B25648-7 or
65B26469-15
(a) (b)65B25648-8 or
65B26469-16
Reinforcement Angle R/H165B25648-8 or
65B26469-16
(c) (d)BACB30MY5K*Bolt74BACB30MY6K4
(c) (d)BACB30MY5K*Bolt6BACB30MY6K5
(c) (d)BACB30MY5K*Bolt2BACB30MY6K6
(c) (d)BACB30MY8K*Bolt2BACB30MY8K6X
(c) (d)BACB30MY8K*Bolt12BACB30MY8K7X
(c) (d)BACB30MY8K*Bolt4BACB30MY8K8X
(c) (d)BACB30NW6K*Bolt6BACB30NW6K3X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt20BACB30NW6K5X
(c) (d)BACB30MY6K*Bolt3BACB30NX6K4X
(c) (d)BACB30MY6K*Bolt18BACB30NX6K5X
(c) (d)BACB30MY6K*Bolt3BACB30NX6K6X
(c)-Collar14BACC30BH6
(c)-Collar120BACC30M6
(c)-Collar18BACC30M8
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
116 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 117

Group 5:
Upper Deck Floor Beam Station (STA) 1080
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACR15BB5D*Rivet93BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet58BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet5BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet9BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D8C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
Group 5:
Upper Deck Floor Beam Station (STA) 1100
NotesExisting Part NumberNameQTYPart Number /
Specification
(a) (b)65B25649-2Upper Chord165B25649-2
(a) (b)65B25649-7Reinforcement Angle L/H165B25649-7
(a) (b)65B25649-8Reinforcement Angle R/H165B25649-8
(c) (d)BACB30MY5K*Bolt61BACB30MY6K4
(c) (d)BACB30MY6K*Bolt2BACB30MY6K4X
(c) (d)BACB30MY5K*Bolt3BACB30MY6K5
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
117 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 118

Group 5:
Upper Deck Floor Beam Station (STA) 1100
NotesExisting Part NumberNameQTYPart Number /
Specification
(c) (d)BACB30MY6K*Bolt14BACB30MY6K5X
(c) (d)BACB30MY8K*Bolt18BACB30MY8K7X
(c) (d)BACB30NW6K*Bolt8BACB30NW6K4X
(c) (d)BACB30NW6K*Bolt12BACB30NW6K5X
(c) (d)BACB30NW6K*Bolt16BACB30NW6K6X
(c) (d)BACB30NX6K*Bolt6BACB30NX6K3X
(c) (d)BACB30NX6K*Bolt2BACB30NX6K4X
(c) (d)BACB30NX6K*Bolt6BACB30NX6K5X
(c) (d)BACB30NX6K*Bolt11BACB30NX6K6X
(c) (d)BACB30NX6K*Bolt6BACB30NX6K7X
(c) (d)BACB30NX6K*Bolt4BACB30NX6K8X
(c) (d)BACB30NX6K*Bolt1BACB30NX6K9X
(c) (d)BACB30NX6K*Bolt1BACB30NX6K10X
(c) (d)BACB30NX6K*Bolt1BACB30NX6K11X
(c)-Collar54BACC30BH6
(c)-Collar100BACC30M6
(c)-Collar18BACC30M8
(c) (d)BACR15BB5D*Rivet14BACR15BB5D5C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet108BACR15BB5D6C or
BACR15BB6D*C
(c) (d)BACR15BB5D*Rivet15BACR15BB5D7C or
BACR15BB6D*C
(c) (d)BACR15BB6D*Rivet4BACR15BB6D7C or
BACR15BB7D*C
(c) (d)BACR15BB6D*Rivet3BACR15BB6D8C or
BACR15BB7D*C
(e)-Chemical Conversion Coating4 OuncesType 2, Class A
(f)-Primer1/4 PintBMS 10-11, Type I
(f)-Sealant4 OuncesBMS 5-95, Class B
(f)-Corrosion Inhibiting Compound8 OuncesBMS 3-23, Type II,
Class 2
(a) Fabricate a new part. Refer to APPENDIX A.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
118 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 119

Group 5:
Upper Deck Floor Beam Station (STA) 1100
NotesExisting Part NumberNameQTYPart Number /
Specification
(b) Discard the existing part.
(c) Refer to 747 Structural Repair Manual Chapter 51 for alternative fasteners.
(d) Use oversize bolts. Use oversize rivets when the rivet hole in the web or frame must be oversized to
correct damage or misalignment. At locations where a larger than original rivet will be installed, verify
grip length on installation.
(e) Refer to SOPM 20-43-03 for supplier data.
(f) See the Qualified Products List at the end of the Boeing Material Specification (BMS) for supplier data.
3. Parts Modified and Reidentified:
None.
4. Parts Removed and Not Replaced:
None.
D. Parts Necessary to Change Spares
None.
E. Special Tooling - Price and Availability
None.
F. Special Tooling Necessary to do this Service Bulletin
No special tools or equipment are necessary to do the change in this service bulletin. But, maintenance
and overhaul tools in the manuals given in Paragraph 1.J., References, can be necessary. Examine
operator tool supply to make sure all necessary tools are available.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
119 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 120

Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
120 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT
BLANK PAGE

### Page 121

3.    ACCOMPLISHMENT INSTRUCTIONS
A. GENERAL INFORMATION
CAUTION: KEEP THE WORK AREA, WIRES AND ELECTRICAL BUNDLES CLEAN OF METAL
PARTICLES OR CONTAMINATION WHEN YOU USE TOOLS. UNWANTED MATERIAL,
METAL PARTICLES OR CONTAMINATION CAUGHT IN WIRE BUNDLES CAN CAUSE
DAMAGE TO THE BUNDLES. DAMAGED WIRE BUNDLES CAN CAUSE SPARKS OR
OTHER ELECTRICAL DAMAGE.
NOTE: 1. Manual titles are referred to by acronyms. Refer to Paragraph 1.J., References, for
definition of the acronyms.
2. Obey all of the warnings and cautions given in the specified manual sections.
3. Unless shown differently, these dimensions and tolerances are used:
– Linear dimensions are in inches
– Tolerance on linear dimensions, other than rivet and bolt edge margins, is plus
or minus 0.03 inch
– Tolerance on rivet and bolt edge margin is plus or minus 0.05 inch
– Angular tolerance is plus or minus 2 degrees
– Hole dimensions for standard solid rivets and fasteners are in Structural Repair
Manual (SRM) Chapter 51
– Torque limits to tighten nuts and bolts are in SRM Chapter 51
4. Use the approved fastener and process material substitutions in accordance with
SRM Chapter 51.
5. If the length of any fastener specified in this service bulletin does not meet installation
standards given in SRM Chapter 51, then a fastener of the same specification, or
an approved substitute, with a length which meets the installation standards given
in SRM Chapter 51 may be used. In addition, washers may be installed for fastener
grip length in accordance with SRM Chapter 51.
6. A Detailed Inspection is defined as: An intensive examination of a specific item,
installation, or assembly to detect damage, failure, or irregularity. Available lighting
is normally supplemented with a direct source of good lighting at an intensity deemed
appropriate. Inspection aids such as mirrors, magnifying lenses, etc. may be
necessary. Surface cleaning and elaborate procedures may be required.
7. These work instructions refer to procedures included in other Boeing documents.
When the words "refer to" are used and the operator has an accepted alternative
procedure, the accepted alternative procedure can be used. When the words "in
accordance with" are included in the instruction, the procedure in the Boeing document
must be used.
8. Refer to Appendix A to identify the parts to be replaced and the material used to
make replacement parts. The appendix lists the drawing numbers for fabrication,
installation, and fastener requirements.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
121 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 122

9. Fasteners may be oversized 1/64 or 1/32 inch as needed. Maintain 1.7D edge margin
on the upper chord and all adjacent parts. At fasteners common to the floor beam
to frame connection, 1.5D minimum edge margin is acceptable in Section 41 with a
reduced after-modification inspection threshold as given in Paragraph 1.E.,
Compliance. Edge margin is defined as the distance from the edge of the part to the
center of the hole, and "D" is the hole diameter.
10. The instructions in Paragraph 3.B., Work Instructions and the figures can include
operation of tools or test equipment. Boeing Engineering Tool Drawings, the Illustrated
Tool and Equipment Manual, and the Special Tool and Ground Handling Drawing
Index contain data on versions of the tools or test equipment that you can use. It is
permitted to use replaced tools. It is not permitted to use superseded tools.
11. If it is necessary to remove more parts for access, you can remove those parts. If
you can get access without removing identified parts, it is not necessary to remove
all of the identified parts. Jacking and shoring limitations must be observed.
12. Where the work instructions include installation of a kept part, a new or serviceable
part with the same part number can be installed as an alternative to the kept part.
13. Boeing Service Letter 747-SL-51-048, Damage Reporting and Repair Plan/Design
Guidelines, is an acceptable procedure to request information from Boeing for
additional structural repair instructions. The Service Letter describes what information
must be provided to Boeing before a structural repair can be provided.
14. Shaded areas in Figures are reference only. Shaded areas in Figures may look
different than your airplane.
15. Install all bolts in transition fit holes. Transition fit hole sizes are given in 747 SRM,
Chapter 51.
16. Boeing recommends installation of oversize fasteners at all bolt locations. At rivet
locations, install the original size rivet provided the hole meets the acceptable surface
defect criteria for fastener holes given in SRM, Chapter 51.
17. Refer to Appendix B for a Fastener Replacement Guide.
18. Upper chord replacement is only required at "full length" upper deck floor beams aft
of station (STA) 360 that span the entire width of the airplane from the left side of
body frame to the right side of body frame.
B. WORK INSTRUCTIONS
PART 1 - Access
1. For access to the upper deck floor beams from above, remove the equipment that follows, as
necessary:
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
122 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 123

Group 1, 3, 5:
Refer to AMM Subject as an accepted procedureEquipment
747-100/200/300 AMM 25-16-01Flight Compartment Floor Covering
747-100/200/300 AMM 25-24-16Upper Deck Closets
747-100/200/300 AMM 25-24-18
747-100/200/300 AMM 25-24-25
747-100/200/300 AMM 25-24-47
747-100/200/300 AMM 25-25-01Upper Deck Passenger Seat
747-100/200/300 AMM 25-27-05Upper Deck Floor Covering
747-100/200/300 AMM 25-31-05Upper Deck Galleys
747-100/200/300 AMM 25-31-06
747-100/200/300 AMM 25-40-03Upper Deck Lavatories
747-100/200/300 AMM 53-21-02Upper Deck Floor Panels
-Crew Rest Area
Group 2, 4, 6:
Refer to AMM Subject as an accepted procedureEquipment
747-100/200/300 AMM 25-16-01Flight Compartment Floor Covering
747-100/200/300 AMM 25-25-01Upper Deck Passenger Seat
747-100/200/300 AMM 25-27-05Upper Deck Floor Covering
747-100/200/300 AMM 25-24-02Closets
747-100/200/300 AMM 25-24-16
747-100/200/300 AMM 25-24-18
747-100/200/300 AMM 25-24-25
747-100/200/300 AMM 25-24-33
747-100/200/300 AMM 25-24-47
747-100/200/300 AMM 25-33-12Crew Galley - Upper Deck
747-100/200/300 AMM 25-40-03Lavatory
747-100/200/300 AMM 53-21-02Upper Deck Floor Panels
-Crew Rest Area
2. For access to the upper deck floor beams from below, remove the equipment that follows, as
necessary:
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
123 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 124

Group 1, 3, 5:
Refer to AMM Subject as an accepted procedureEquipment
747-100/200/300 AMM 25-21-04Ceiling Insulation
747-100/200/300 AMM 25-22-01Ceiling Access Panels
747-100/200/300 AMM 25-23-01Passenger Service Units
747-100/200/300 AMM 25-25-01Passenger Seats
747-100/200/300 AMM 25-28-07Center Overhead Stowage Compartments
747-100/200/300 AMM 25-28-10Side Overhead Stowage Compartments
Group 2, 4, 6:
Refer to AMM Subject as an accepted procedureEquipment
747-100/200/300 AMM 25-59-01Main Deck Cargo Compartment Ceiling Lining
747-100/200/300 AMM 25-59-05Main Deck Ceiling Insulation
PART 2 - Upper Deck Floor Beam Upper Chord Removal and Structure Inspection
CAUTION: DO NOT REMOVE ADJACENT FLOOR BEAM UPPER CHORDS AT THE SAME TIME.
IF ADJACENT FLOOR BEAM UPPER CHORDS ARE REMOVED AT THE SAME TIME,
DAMAGE TO THE AIRPLANE STRUCTURE MAY OCCUR.
1. Remove the existing upper chords and reinforcing straps or angles from the upper deck floor
beams at the locations where replacement is required as shown in the applicable figure as follows:
FIGURE 1Group 1-2
FIGURE 2Group 3-4
FIGURE 3Group 5
FIGURE 4Group 6
2. Do the following inspections:
a. Do an open hole High Frequency Eddy Current (HFEC) inspection for cracks at all locations
in the floor beam webs and side of body frames where fasteners were removed to remove
the upper chords and reinforcing straps. Do this inspection for cracks in accordance with 747
NDT Part 6, 51-00-00, Figure 16.
b. Do a detailed inspection for cracks in any parts that were removed and will be re-installed.
c. If any crack is found, replace the cracked part or contact Boeing for repair instructions and
do the repair. Refer to Part 3 - Upper Deck Floor Beam Upper Chord Fabrication and Installation
for the replacement of cracked parts.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
124 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 125

PART 3 - Upper Deck Floor Beam Upper Chord Fabrication and Installation
1. For each floor beam location where replacement is required as shown in the applicable FIGURE
1 or FIGURE 2 or FIGURE 3 or FIGURE 4, make a new upper chord and associated straps or
angles.
a. Fabricate a new upper chord and straps or angles. Refer to APPENDIX A for the applicable
parts and fabrication requirements. Use the existing parts as a guide and to match the profile
of the existing chord to frame attachment.
b. Apply one coat of Type 2, Class A chemical conversion coating to bare aluminum surfaces.
Refer to SOPM 20-43-03.
c. Apply two coats of BMS 10-11, Type 1 primer to the new parts. Refer to SOPM 20-41-02.
2. For each floor beam location where replacement is required as shown in the applicable FIGURE
1 or FIGURE 2 or FIGURE 3 or FIGURE 4, install a new upper chord, new associated reinforcing
straps or angles, and any kept or replaced parts in accordance with the applicable production
drawings (Refer to APPENDIX A). In Section 41, also refer to Service Bulletin 747-53-2272 as
necessary.
NOTE: Fastener holes may be oversized up to 1/32 inch to correct damage or misalignment. If
more than 1/32 inch oversize is necessary, contact Boeing. At rivet locations where the
hole was already oversized during accomplishment of Service Bulletin 747-53-2272, do
not further oversize the hole, and install the same diameter rivet as was called out for SB
747-53-2272. At bolt locations where the hole was already oversized during
accomplishment of Service Bulletin 747-53-2272, make the hole an additional 1/64 inch
oversize and install oversize fastener. If further oversizing is necessary to meet hole
quality requirements, contact Boeing for instructions.
NOTE: Make sure a minimum edge margin of 1.7D is maintained in both floor beam and body
frame. At fasteners common to the floor beam to frame connection, 1.5D minimum edge
margin is acceptable in Section 41 with a reduced after-modification inspection threshold
as given in Paragraph 1.E., Compliance.
NOTE: Install bolts common to the upper chord wet using BMS 5-95 sealant. Refer to SOPM
20-50-19.
3. After upper chord replacement is complete, reapply BMS 3-23, Type II, Class 2 Corrosion Inhibiting
Compound (CIC) to the new upper chord structure and fasteners.
PART 4 - After Replacement Inspections
1. At the time given in Paragraph 1.E., Compliance, of this service bulletin, do inspections as follows:
a. Do open hole HFEC inspection at the floor panel attachment holes and surface HFEC
inspection at the permanent fastener locations for cracks in the replaced upper deck floor
beam chords, in accordance with Service Bulletin 747-53A2452.
b. Do HFEC inspections of the upper deck floor beam upper chords at strap/frame connections
in accordance with Structural Significant Items (SSI) F-19D, F-19H, F-20B, and F-20G of
Supplemental Structural Inspection Document (SSID) D6-35022, Revision G, dated December
2000. Inspections are only required at locations identified in the SSID.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
125 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 126

2. If any crack is found, contact Boeing for repair instructions and do the repair.
3. If no crack is found, do repeat inspections as follows:
a. Repeat open hole HFEC inspection at floor panel attachment holes and surface HFEC
inspection at permanent fastener locations in accordance with Service Bulletin 747-53A2452,
at the interval given in Paragraph 1.E., Compliance.
b. Repeat HFEC inspections of the upper deck floor beam upper chords at strap/frame
connections in accordance with Structural Significant Items (SSI) F-19D, F-19H, F-20B, and
F-20G of Supplemental Structural Inspection Document (SSID) D6-35022, Revision G, dated
December 2000, at the interval given in Paragraph 1.E., Compliance. Inspections are only
required at locations identified in the SSID.
4. Do the chord removal, open hole HFEC inspections, detailed inspections, chord fabrication, and
new chord installation actions again, in accordance with PART 2 and PART 3, at the time given
in Paragraph 1.E., Compliance.
PART 5 - Restoration
1. For restoration above the upper deck floor beams, install removed equipment. Refer to the following
procedures, as necessary:
Group 1, 3, 5:
Refer to AMM Subject as an accepted procedureEquipment
747-100/200/300 AMM 25-16-01Flight Compartment Floor Covering
747-100/200/300 AMM 25-24-16Upper Deck Closets
747-100/200/300 AMM 25-24-18
747-100/200/300 AMM 25-24-25
747-100/200/300 AMM 25-24-47
747-100/200/300 AMM 25-25-01Upper Deck Passenger Seat
747-100/200/300 AMM 25-27-05Upper Deck Floor Covering
747-100/200/300 AMM 25-31-05Upper Deck Galleys
747-100/200/300 AMM 25-31-06
747-100/200/300 AMM 25-40-03Upper Deck Lavatories
747-100/200/300 AMM 53-21-02Upper Deck Floor Panels
-Crew Rest Area
Group 2, 4, 6:
Refer to AMM Subject as an accepted procedureEquipment
747-100/200/300 AMM 25-16-01Flight Compartment Floor Covering
747-100/200/300 AMM 25-25-01Upper Deck Passenger Seat
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
126 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 127

Group 2, 4, 6:
Refer to AMM Subject as an accepted procedureEquipment
747-100/200/300 AMM 25-27-05Upper Deck Floor Covering
747-100/200/300 AMM 25-24-02Closets
747-100/200/300 AMM 25-24-16
747-100/200/300 AMM 25-24-18
747-100/200/300 AMM 25-24-25
747-100/200/300 AMM 25-24-33
747-100/200/300 AMM 25-24-47
747-100/200/300 AMM 25-33-12Crew Galley - Upper Deck
747-100/200/300 AMM 25-40-03Lavatory
747-100/200/300 AMM 53-21-02Upper Deck Floor Panels
-Crew Rest Area
2. For restoration below the upper deck floor beams, install removed equipment. Refer to the following
procedures, as necessary:
Group 1, 3, 5:
Refer to AMM Subject as an accepted procedureEquipment
747-100/200/300 AMM 25-21-04Ceiling Insulation
747-100/200/300 AMM 25-22-01Ceiling Access Panels
747-100/200/300 AMM 25-23-01Passenger Service Units
747-100/200/300 AMM 25-25-01Passenger Seats
747-100/200/300 AMM 25-28-07Center Overhead Stowage Compartments
747-100/200/300 AMM 25-28-10Side Overhead Stowage Compartments
Group 2, 4, 6:
Refer to AMM Subject as an accepted procedureEquipment
747-100/200/300 AMM 25-59-01Main Deck Cargo Compartment Ceiling Lining
747-100/200/300 AMM 25-59-05Main Deck Ceiling Insulation
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
127 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 128

This Figure applies only to: Group 1-2.
FIGURE 1: UPPER DECK FLOOR BEAM - UPPER CHORD - REPLACEMENT LOCATIONS
(SHEET 1 OF 3)
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
128 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 129 (OCR)

BOEING SERVICE BULLETIN 747-53A2852
ALERT  ALERT
STA  STA  STA  STA  STA
STA  460  480  500  520  540  560
STA  STA
STA  400
330  STA  380
STA  360
340
UPPER CHORD
REPLACEMENT LOCATION
FWD  2155407
FIGURE 1: UPPER DECK FLOOR BEAM - UPPER CHORD - REPLACEMENT LOCATIONS
(SHEET 2 OF 3)
Original Issue: June 22, 2012
PROPRIETARY - Copyright © Unpublished  Export Controlled ECCN: 9E991 - BOEING  747-53A2852
Work - See page 1 for details.  129 of 189

### Page 130 (OCR)

BOEING SERVICE BULLETIN 747-53A2852
ALERT  ALERT
STA  STA  STA  STA  STA  STA  STA  STA  STA  SIA
580  600  620  640  660  680  700  720  740
FWD
NOT INSTALLED ON ALL
AIRPLANES
UPPER CHORD  2155421
REPLACEMENT LOCATION
FIGURE 1: UPPER DECK FLOOR BEAM - UPPER CHORD - REPLACEMENT LOCATIONS
(SHEET 3 OF 3)
Original Issue: June 22, 2012
Export Controlled ECCN: 9E991 - BOEING  PROPRIETARY - Copyright © Unpublished  747-53A2852
Work - See page 1 for details.  130 of 189

### Page 131

This Figure applies only to: Group 3-4.
FIGURE 2: UPPER DECK FLOOR BEAM - UPPER CHORD - REPLACEMENT LOCATIONS
(SHEET 1 OF 3)
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: June 22, 2012
747-53A2852
131 of 189
BOEING SERVICE BULLETIN 747-53A2852
ALERTALERT

### Page 132 (OCR)

BOEING SERVICE BULLETIN 747-53A2852
ALERT  ALERT
STA  STA  STA  STA  STA
STA  440  STA  460  STA  480  500  520  540  560
STA  420
STA  400
STA  380
STA  360
340
UPPER CHORD
REPLACEMENT LOCATION  FWD
2155435
FIGURE 2: UPPER DECK FLOOR BEAM - UPPER CHORD - REPLACEMENT LOCATIONS
(SHEET 2 OF 3)
Original Issue: June 22, 2012  Export Controlled ECCN: 9E991 - BOEING  747-53A2852
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.  132 of 189

The text continues at https://openairdocs.org/service-documents/boeing/747-53a2852/file/5f45669c09d2.md?from=133

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.