# Boeing Alert Requirements Bulletin 757-53A0120 RB: No revision named, part 2 of 2

- Rights: © The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2023-1214; AD 2024-07-05 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Boeing Alert Requirements Bulletin 757-53A0120 RB](https://openairdocs.org/service-documents/boeing/757-53a0120-rb.md)
- Title as filed: 757-53A0120 RB_Part2
- Pages: 11
- PDF: https://openairdocs.org/files/sha256/f7/f2/f7f27dc5fbe91ea1ce39a2f3c3d35a40f3c38dd656327ec70c7043bbea7b8480
- Page: https://openairdocs.org/service-documents/boeing/757-53a0120-rb/file/f7f27dc5fbe9

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1 (OCR)

REQUIREMENTS BULLETIN 757-53A0120
ALERT  ALERT
INTERCOSTAL TEE CLIP
UPPER SKIN ~
OPEN LINER  S-14L-
HOLE (TYPICAL)
S-14
INTERCOSTAL
STRAP
LOWER HINGE
FITTING
FITTING•  - FRAME WEB
SUPPORT TEE -
FITTING FASTENER
OUTER CHORD-
BEAR STRAP '  - FITTING
S-15L
LOWER SKIN
INBD
A-A
SURFACE HIGH FREQUENCY  0649267
EDDY CURRENT INSPECTION
FIGURE 15: LEFT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND AN OPEN LINER HOLE
(SHEET 2 OF 3)
Original Issue: January 17, 2022
757-53A0120 RB
Export Controlled ECCN: 9E991
Copyright © Unpublished Work - See page 1 for details.  194 of 204

### Page 2

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1-FRAME WEBInspect1
(b)1-FRAME WEBInspect2
(a) Do a surface High Frequency Eddy Current (HFEC) inspection of the frame web around the open hole
for any crack in accordance with 757 NDT Manual Part 6, 51-00-19.
(b) Do a surface High Frequency Eddy Current (HFEC) inspection of the frame web around the fitting fastener
for any crack in accordance with 757 NDT Manual Part 6, 51-00-19.
FIGURE 15: LEFT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND AN OPEN LINER HOLE
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished Work - See page 1 for details.
Original Issue: January 17, 2022
757-53A0120 RB
195 of 204
REQUIREMENTS BULLETIN 757-53A0120
ALERTALERT

### Page 3 (OCR)

REQUIREMENTS BULLETIN 757-53A0120
ALERT  ALERT
This Figure applies only to: Group 3.
/ STA
1640
STA
1640
S-13R
LOWER
HINGE
INTERCOSTAL
S-14R
S-15R -
S-16R -  .....
FLOOR
S-17R
2974757
FIGURE 16: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - GENERAL
VISUAL INSPECTION
(SHEET 1 OF 3)
Original Issue: January 17, 2022
757-53A0120 RB
Export Controlled ECCN: 9E991
Copyright © Unpublished Work - See page 1 for details.  196 of 204

### Page 4 (OCR)

REQUIREMENTS BULLETIN 757-53A0120
ALERT  ALERT
INTERCOSTAL TEE CLIP
UPPER SKIN
- S-14R
S-14 -
INTERCOSTAL
STRAP
LOWER HINGE
FITTING
FRAME WEB 1  LINER HOLE
(TYPICAL)
• SUPPORT TEE
OUTER CHORD
FITTING-  BEAR STRAP
• S-15R
LOWER SKIN
INBD
A-A
• GENERAL VISUAL  2974761
INSPECTION
FIGURE 16: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - GENERAL
VISUAL INSPECTION
(SHEET 2 OF 3)
Original Issue: January 17, 2022
757-53A0120 RB
Export Controlled ECCN: 9E991
Copyright © Unpublished Work - See page 1 for details.  197 of 204

### Page 5

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1-FRAME WEBInspect1
(a) Do a General Visual Inspection of the frame web on the aft side for existing liner hole.
FIGURE 16: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - GENERAL
VISUAL INSPECTION
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished Work - See page 1 for details.
Original Issue: January 17, 2022
757-53A0120 RB
198 of 204
REQUIREMENTS BULLETIN 757-53A0120
ALERTALERT

### Page 6 (OCR)

REQUIREMENTS BULLETIN 757-53A0120
ALERT  ALERT
This Figure applies only to: Group 3.
/ STA
1640
STA
1640
S-13R -
LOWER
HINGE
INTERCOSTAL
S-14R
S-15R •
S-16R -  ............
FLOOR
S-17R
2974759
FIGURE 17: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND A PLUGGED LINER HOLE
(SHEET 1 OF 3)
Original Issue: January 17, 2022
757-53A0120 RB
Export Controlled ECCN: 9E991
Copyright © Unpublished Work - See page 1 for details.  199 of 204

### Page 7 (OCR)

REQUIREMENTS BULLETIN 757-53A0120
ALERT  ALERT
INTERCOSTAL TEE CLIP
• UPPER SKIN
S-14R
S-14
INTERCOSTAL
STRAP
LOWER HINGE
FITTING
FRAME WEB -
WITH ONE A  - SUPPORT TEE
FASTENER
OR
WITH TWO
FASTENERS
OUTER CHORD
FITTING  BEAR STRAP
S-15R
A-A  LOWER SKIN
FITTING  INBD
FASTENER
PLUGGED
LINER HOLE
• FITTING  (TYPICAL)
INBD  INBD  FITTING
WITH ONE  WITH TWO
FASTENER  FASTENERS
SURFACE HIGH FREQUENCY  2974762
EDDY CURRENT INSPECTION
FIGURE 17: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND A PLUGGED LINER HOLE
(SHEET 2 OF 3)
Original Issue: January 17, 2022
Export Controlled ECCN: 9E991  757-53A0120 RB
Copyright © Unpublished Work - See page 1 for details.  200 of 204

### Page 8

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)(b)1-FRAME WEBInspect1
(a) Do a surface High Frequency Eddy Current (HFEC) inspection of the frame web around the fitting fastener
and the fastener in the plugged liner hole (if an adjacent second fastener exists) for any crack in accordance
with 757 NDT Manual Part 6, 51-00-19.
(b) There can be 1 or 2 fastener hole locations to inspect.
FIGURE 17: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND A PLUGGED LINER HOLE
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished Work - See page 1 for details.
Original Issue: January 17, 2022
757-53A0120 RB
201 of 204
REQUIREMENTS BULLETIN 757-53A0120
ALERTALERT

### Page 9 (OCR)

REQUIREMENTS BULLETIN 757-53A0120
ALERT  ALERT
This Figure applies only to: Group 3.
STA
1640
STA
1640
S-13R  000
LOWER-
HINGE
INTERCOSTAL
S-14R -
S-15R
...°
S-16R -  - oooooooo
FLOOR
S-17R
2975793
FIGURE 18: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND AN OPEN LINER HOLE
(SHEET 1 OF 3)
Original Issue: January 17, 2022
757-53A0120 RB
Export Controlled ECCN: 9E991
Copyright © Unpublished Work - See page 1 for details.  202 of 204

### Page 10 (OCR)

REQUIREMENTS BULLETIN 757-53A0120
ALERT  ALERT
INTERCOSTAL TEE CLIP
• UPPER SKIN
•S-14R  OPEN LINER
S-14  HOLE (TYPICAL)
INTERCOSTAL
STRAP
LOWER HINGE
FITTING
FRAME WEB  - FITTING
SUPPORT TEE
•
FITTING FASTENER
OUTER CHORD
FITTING  BEAR STRAP
S-15R
LOWER SKIN
INBD
A-A
SURFACE HIGH FREQUENCY  2975796
EDDY CURRENT INSPECTION
FIGURE 18: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND AN OPEN LINER HOLE
(SHEET 2 OF 3)
Original Issue: January 17, 2022
757-53A0120 RB
Export Controlled ECCN: 9E991
Copyright © Unpublished Work - See page 1 for details.  203 of 204

### Page 11

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)1-FRAME WEBInspect1
(b)1-FRAME WEBInspect2
(a) Do a surface High Frequency Eddy Current (HFEC) inspection of the frame web around the open hole
for any crack in accordance with 757 NDT Manual Part 6, 51-00-19.
(b) Do a surface High Frequency Eddy Current (HFEC) inspection of the frame web around the fitting fastener
for any crack in accordance with 757 NDT Manual Part 6, 51-00-19.
FIGURE 18: RIGHT SIDE - FUSELAGE FRAME WEB AT STA 1640 BETWEEN S-14 AND S-15 - SURFACE
HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION AROUND AN OPEN LINER HOLE
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished Work - See page 1 for details.
Original Issue: January 17, 2022
757-53A0120 RB
204 of 204
REQUIREMENTS BULLETIN 757-53A0120
ALERTALERT

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.