Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
RADIUS
2 SO RADIUS  FILLER "L"
(5X7) RADIUS  FILLER "I"  ' FILLER "K"  201
FILLER J
FILLER 'O'  5)
RADIUS
2 € 10 RADIUS.  FILLER "N"  FWD  FILLER "P"
5) 10) RADIUS  'FILLER "M"
C-C
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for one side of the airplane.
Step  Task  Name  Identification  Qty  More Data
Locate  FITTING, UNDER-  111T4020U7  1
WING LONGERON, LH
Locate  FITTING, INTERNAL  1
BATHTUB
Locate  SHIM, LAMINATED  BACS40R016B018F  1  (a) Shim A.
Locate  SHIM, LAMINATED  BACS40R020C032F  1  (a) Shim B.
Locate  SHIM, LAMINATED  BACS40R014C022F  1  (a) Shim C.
Locate  SHIM, LAMINATED  BACS40R025C063F  2  (a) (p) Shim D.
Locate  RADIUS FILLER  16  (b)
Drill  HOLE  (c)(d) Drill and ream
to final hole size.
Refer to the fastener
code table.
FIGURE 15: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 3 OF 8)
Original Issue: October 10, 2024
767-57A0148 RB
Export Controlled ECCN: 9E991
See page 1 for details  295 of 416

### Page 2

More DataQtyIdentificationNameTaskStep
(c)(d)(e) Drill and
ream to final hole
size. Refer to the
fastener code table.
42-HOLEDrill4
(f)16-RADIUS FILLERRemove / Keep5
Shim A.1BACS40R016B018FSHIM, LAMINATEDRemove / Keep
Shim B.1BACS40R020C032FSHIM, LAMINATEDRemove / Keep
Shim C.1BACS40R014C022FSHIM, LAMINATEDRemove / Keep
(p) Shim D.2BACS40R025C063FSHIM, LAMINATEDRemove / Keep
-1-FITTING, INTERNAL
BATHTUB
Remove / Keep
-1111T4020U7FITTING, UNDER-
WING LONGERON, LH
Remove / Keep
Clean and deburr all
structure.
--STRUCTUREClean/Deburr
(g)1111T4020U7FITTING, UNDER-
WING LONGERON, LH
Install (New)6
(h)12-RADIUS FILLERInstall (Kept)7
(i) Refer to the fas-
tener code table.
34-FASTENERInstall (New)8
(j) Shim A.1BACS40R016B018FSHIM, LAMINATEDInstall (Kept)9
(j) Shim B.1BACS40R020C032FSHIM, LAMINATEDInstall (Kept)
(j) Shim C.1BACS40R014C022FSHIM, LAMINATEDInstall (Kept)
(j)1-FITTING, INTERNAL
BATHTUB
Install (Kept)
-1-TEMPORARY TEN-
SION BOLT
Install (New)
(k)4-RADIUS FILLERInstall (Kept)10
(l) Refer to the fas-
tener code table.
8-FASTENERInstall (New)11
FIGURE 15: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 4 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
296 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 3

More DataQtyIdentificationNameTaskStep
-1-TEMPORARY TEN-
SION BOLT
Remove12
Ream and deburr
the tension bolt hole
to final hole size.
Refer to the fastener
code table.
1-HOLEReam
(l) Refer to the fas-
tener code table.
1-FASTENERInstall (New)
(m)(p) Shim D.2BACS40R025C063FSHIM, LAMINATEDInstall (Kept)13
(l)3-FASTENERInstall (New)14
(n)5 OzBMS 5-45SEALANTApply15
(o)5 OzBMS 5-95SEALANTApply16
(a) Peel the shim as required to get a maximum gap of 0.005 inch.
(b) If a radius filler was removed from locations "A" through "P". Locate in the recorded orientation from re-
moval.
(c) Keep a minimum of 1.7D edge margin at all fastener locations on the underwing longeron fitting.
(d) For existing fastener that is nominal, first, or second oversized, install the same type and size fastener if
open hole HFEC confirms crack-free condition.
(e) Oversizing to second oversize fastener requires high interference cold-working. Cold work the hole in
accordance with 767-200 SRM 51-40-09 or 767-200SF SRM 51-40-09 or 767-300 SRM 51-40-09 or 767-
300BCF SRM 51-40-09 or 767-300F SRM 51-40-09.
(f) If a radius filler was removed from locations "A" through "P". Record the orientation of the radius filler at
each location for re-installation.
(g) Apply BMS 5-95 faying surface seal to the mating surface of the lower panel and the underwing longeron
fitting. Refer to SOPM 20-50-19 as an accepted procedure.
(h) If a radius filler was removed from locations "C" through "L", "O", and "P". Locate in the recorded orientation
from removal.
(i) Install the fasteners wet with BMS 5-45 to partially install the underwing longeron fitting. Refer to SOPM
20-50-19, and 767-200 SRM 51-40-02 or 767-200SF SRM 51-40-02 or 767-300 SRM 51-40-02 or 767-
300BCF SRM 51-40-02 or 767-300F SRM 51-40-02 as accepted procedures.
Do not install fasteners common to the internal bathtub fitting or the three forward fasteners that are
common to the underwing longeron fitting.
(j) Apply BMS 5-45 faying surface seal. Refer to SOPM 20-50-19 as an accepted procedure.
(k) If a radius filler was removed from locations "A", "B", "M", and "N". Install in the recorded orientation.
(l) Install fasteners wet with BMS 5-45. Refer to SOPM 20-50-19 as an accepted procedure.
(m) Apply BMS 5-95 faying surface seal to each shim. Refer to SOPM 20-50-19 as an accepted procedure.
FIGURE 15: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 5 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
297 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 4

More DataQtyIdentificationNameTaskStep
(n) Apply cap seal to wing tank fasteners internally with BMS 5-45. Refer to 767 AMM 28-11-00 as an accepted
procedure.
(o) Apply BMS 5-95 to fillet seal around the perimeter of the underwing longeron fitting. Refer to SOPM 20-
50-19 as an accepted procedure.
(p) One or both Shim D may not have been previously installed. Install the necessary number of shim(s)
based on the findings during fitting removal. If shim(s) must be added at a location, use the appropriate
number of shim(s) as necessary.
The codes shown below agree with the letter shown in the upper left corner of the fastener symbols in the figure.
A number in the lower right corner gives the grip length of the fastener. The QTY numbers shown below are the
number of fasteners necessary for this figure.
More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.2621-0.264128BACB30NX8K( )XBOLT, PROTRUDING
HD
A
--28BACC30BH8COLLAR
Second oversize fastener.0.2777-0.279728BACB30NX8K( )YBOLT, PROTRUDING
HD
--28BACC30AC8COLLAR
First oversize fastener.0.3246-0.326611BACB30NX10K( )XBOLT, PROTRUDING
HD
B
---BACC30BH10COLLAR
Second oversize fastener.0.3402-0.342211BACB30NX10K( )YBOLT, PROTRUDING
HD
--11BACC30AC10COLLAR
FIGURE 15: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 6 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
298 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 5

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.3871-0.38911BACB30NX12K( )XBOLT, PROTRUDING
HD
C
--1BACC30BH12COLLAR
Second oversize fastener.0.4027-0.40471BACB30NX12K( )YBOLT, PROTRUDING
HD
--1BACC30AC12COLLAR
First oversize fastener.0.4496-0.45161BACB30NX14K( )XBOLTD
--1BACC30BH14COLLAR
Second oversize fastener.0.4652-0.46721BACB30NX14K( )YBOLT
--1BACC30AC14COLLAR
First oversize fastener (if
5/16 inch hi-lok was in-
stalled.)
0.3246-0.32661BACB30NX10K( )XBOLT, PROTRUDING
HD
E
--1BACC30BH10COLLAR
Second oversize fastener.0.3402-0.34221BACB30NX10K( )YBOLT, PROTRUDING
HD
--1BACC30AC10COLLAR
First oversize fastener (if
5/16 inch bolt and nut was
installed.)
0.3276-0.32861BACB30US5K( )XBOLT, 12 PT HEAD
Under the bolt head.-1BACW10BP51CDWASHER, PLAIN
Under the nut.-1BACW10BP51DPWASHER, PLAIN
Torque nut to 243 to 258
inch lbs.
-1BACN10HR5CDNUT
First oversize fastener.0.6401-0.64113BACB30MR10A26XBOLTF
Under the bolt head.-3BACW10BP101CDWASHER, PLAIN
Under the nut.-3BACW10BP101DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
Second oversize fastener.0.6557-0.65673BACB30MR10A26YBOLT
Under the bolt head.-3BACW10BP102CDWASHER, PLAIN
Under the nut.-3BACW10BP102DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
FIGURE 15: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 7 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
299 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 6

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.5776-0.57861BACB30US9K( )XBOLT, 12 PT HEADG
Under the bolt head.-1BACW10BP91ACWASHER, PLAIN AND
COUNTERSUNK
Self-aligning washer set.
Under the nut.
-1BACW10CA91CVWASHER
Self-aligning washer set.
Under the nut.
-1BACW10CA10CCWASHER
Between nut and self-
aligning washer, for grip
length adjustment.
-1BACW10BP91DPWASHER, PLAIN
Torque nut to 1746 to
1854 inch lbs.
-1BACN10HR9CDNUT
FIGURE 15: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 8 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
300 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 7 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
This Figure applies only to: Group 1, 3.
STA
FUSELAGE  783.04
FRONT SPAR  SKIN  UPPER DRAG
SPLICE ANGLE
UNDERWING  LOWER DRAG
LONGERON  SPLICE ANGLE
FITTING
UNDERWING LONGERON FITTING
3054597
FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 1 OF 8)
Original Issue: October 10, 2024
Export Controlled ECCN: 9E991  767-57A0148 RB
See page 1 for details  301 of 416

### Page 8 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
SEAL RETAINER
FRONT
B  BATHTUB FITTING U€9  INTERNAL  SPAR  B SHIM "A"
059
UNDERWING 1G)  ·16  SHIM "C" O€
LONGERON FITTING
STA
776.21
+  +
SHIM "B" ( 1
8 LOCATIONS  ® A 126
UNDERWING LONGERON
FITTING  3 LOCATIONS
RADIUS  A-A  FWD
FILLER 'B'
RADIUS
FILLER'A'
+ -
RADIUS
FILLER "B"
34 LOCATIONS  RADIUS
FILLER "C"
22
RADIUS
FILLER "D'  SHIM "D"
5)  (2 LOCATIONS)
1 € 13
5) 10 RADIOS  ' FILLER "A"
5 7 RADES  'FILLER "E"
RADIUS  FILLER "F'
FILLER "H"  RADIUS
FILLER "G"  B-B
FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 2 OF 8)
Original Issue: October 10, 2024
767-57A0148 RB
Export Controlled ECCN: 9E991
See page 1 for details  302 of 416

### Page 9 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
RADIUS
RADIUS  FILLER "K"  RADIUS
FILLER "L"  RADIUS  FILLER "I"
FILLER "J"  (2) 5)
RADIUS  RADIUS
FILLER "P"  FILLER "O"  FILLER "N"  RADIUS 2E10
FWD  10
RADIUS
C-C  FILLER "M"
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for one side of the airplane.
Step  Task  Name  Identification  Qty  More Data
1  Locate  FITTING, UNDER-  111T4020U8  1
WING LONGERON,
RH
Locate  FITTING, INTERNAL  1
BATHTUB
Locate  SHIM, LAMINATED  BACS40R016B018F  1  (a) Shim A.
Locate  SHIM, LAMINATED  BACS40R020C032F  1  (a) Shim B.
Locate  SHIM, LAMINATED  BACS40R014C022F  1  (a) Shim C.
Locate  SHIM, LAMINATED  BACS40R025C063F  2  (a) (p) Shim D.
2  Locate  RADIUS FILLER  16  (b)
Drill  HOLE  3  (c)(d) Drill and ream
to final hole size.
Refer to the fastener
code table.
FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T402008 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 3 OF 8)
Original Issue: October 10, 2024
Export Controlled ECCN: 9E991  767-57A0148 RB
See page 1 for details  303 of 416

### Page 10

More DataQtyIdentificationNameTaskStep
(c)(d)(e) Drill and
ream to final hole
size. Refer to the
fastener code table.
42-HOLEDrill4
(f)16-RADIUS FILLERRemove / Keep5
Shim A.1BACS40R016B018FSHIM, LAMINATEDRemove / Keep
Shim B.1BACS40R020C032FSHIM, LAMINATEDRemove / Keep
Shim C.1BACS40R014C022FSHIM, LAMINATEDRemove / Keep
(p) Shim D.2BACS40R025C063FSHIM, LAMINATEDRemove / Keep
-1-FITTING, INTERNAL
BATHTUB
Remove / Keep
-1111T4020U8FITTING, UNDER-
WING LONGERON,
RH
Remove / Keep
Clean and deburr all
structure.
--STRUCTUREClean/Deburr
(g)1111T4020U8FITTING, UNDER-
WING LONGERON,
RH
Install (New)6
(h)12-RADIUS FILLERInstall (Kept)7
(i) Refer to the fas-
tener code table.
34-FASTENERInstall (New)8
(j) Shim A.1BACS40R016B018FSHIM, LAMINATEDInstall (Kept)9
(j) Shim B.1BACS40R020C032FSHIM, LAMINATEDInstall (Kept)
(j) Shim C.1BACS40R014C022FSHIM, LAMINATEDInstall (Kept)
(j)1-FITTING, INTERNAL
BATHTUB
Install (Kept)
-1-TEMPORARY TEN-
SION BOLT
Install (New)
(k)4-RADIUS FILLERInstall (Kept)10
(l) Refer to the fas-
tener code table.
8-FASTENERInstall (New)11
FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 4 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
304 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 11

More DataQtyIdentificationNameTaskStep
-1-TEMPORARY TEN-
SION BOLT
Remove12
Ream and deburr
the tension bolt hole
to final hole size.
Refer to the fastener
code table.
1-HOLEReam
(l) Refer to the fas-
tener code table.
1-FASTENERInstall (New)
(p)(m) Shim D.2BACS40R025C063FSHIM, LAMINATEDInstall (Kept)13
(l)3-FASTENERInstall (New)14
(n)5 OzBMS 5-45SEALANTApply15
(o)5 OzBMS 5-95SEALANTApply16
(a) Peel the shim as required to get a maximum gap of 0.005 inch.
(b) If a radius filler was removed from locations "A" through "P". Locate in the recorded orientation from re-
moval.
(c) Keep a minimum of 1.7D edge margin at all fastener locations on the underwing longeron fitting.
(d) For existing fastener that is nominal, first, or second oversized, install the same type and size fastener if
open hole HFEC confirms crack-free condition.
(e) Oversizing to second oversize fastener requires high interference cold-working. Cold work the hole in
accordance with 767-200 SRM 51-40-09 or 767-200SF SRM 51-40-09 or 767-300 SRM 51-40-09 or 767-
300BCF SRM 51-40-09 or 767-300F SRM 51-40-09.
(f) If a radius filler was removed from locations "A" through "P". Record the orientation of the radius filler at
each location for re-installation.
(g) Apply BMS 5-95 faying surface seal to the mating surface of the lower panel and the underwing longeron
fitting. Refer to SOPM 20-50-19 as an accepted procedure.
(h) If a radius filler was removed from locations "C" through "L", "O", and "P". Locate in the recorded orientation
from removal.
(i) Install the fasteners wet with BMS 5-45 to partially install the underwing longeron fitting. Refer to SOPM
20-50-19, and 767-200 SRM 51-40-02 or 767-200SF SRM 51-40-02 or 767-300 SRM 51-40-02 or 767-
300BCF SRM 51-40-02 or 767-300F SRM 51-40-02 as accepted procedures.
Do not install fasteners common to the internal bathtub fitting or the three forward fasteners that are
common to the underwing longeron fitting.
(j) Apply BMS 5-45 faying surface seal. Refer to SOPM 20-50-19 as an accepted procedure.
(k) If a radius filler was removed from locations "A", "B", "M", and "N". Install in the recorded orientation.
(l) Install fasteners wet with BMS 5-45. Refer to SOPM 20-50-19 as an accepted procedure.
(m) Apply BMS 5-95 faying surface seal to each shim. Refer to SOPM 20-50-19 as an accepted procedure.
FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 5 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
305 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 12

More DataQtyIdentificationNameTaskStep
(n) Apply cap seal to wing tank fasteners internally with BMS 5-45. Refer to 767 AMM 28-11-00 as an accepted
procedure.
(o) Apply BMS 5-95 to fillet seal around the perimeter of the underwing longeron fitting. Refer to SOPM 20-
50-19 as an accepted procedure.
(p) One or both Shim D may not have been previously installed. Install the necessary number of shim(s)
based on the findings during fitting removal. If shim(s) must be added at a location, use the appropriate
number of shim(s) as necessary.
The flag note numbers shown below agree with the numbers shown in the flag symbols in the figure.
More DataFlag Note
Install head on near side.1
Install head on far side.2
The codes shown below agree with the letter shown in the upper left corner of the fastener symbols in the figure.
A number in the lower right corner gives the grip length of the fastener. The QTY numbers shown below are the
number of fasteners necessary for this figure.
More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.2621-0.264128BACB30NX8K( )XBOLT, PROTRUDING
HD
A
--28BACC30BH8COLLAR
Second oversize fastener.0.2777-0.279728BACB30NX8K( )YBOLT, PROTRUDING
HD
--28BACC30AC8COLLAR
FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 6 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
306 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 13

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.3246-0.326611BACB30NX10K( )XBOLT, PROTRUDING
HD
B
--11BACC30BH10COLLAR
Second oversize fastener.0.3402-0.342211BACB30NX10K( )YBOLT, PROTRUDING
HD
--11BACC30AC10COLLAR
First oversize fastener.0.3871-0.38911BACB30NX12K( )XBOLT, PROTRUDING
HD
C
--1BACC30BH12COLLAR
Second oversize fastener.0.4027-0.40471BACB30NX12K( )YBOLT, PROTRUDING
HD
--1BACC30AC12COLLAR
First oversize fastener.0.4496-0.45161BACB30NX14K( )XBOLTD
--1BACC30BH14COLLAR
Second oversize fastener.0.4652-0.46721BACB30NX14K( )YBOLT
--1BACC30AC14COLLAR
First oversize fastener (if
5/16 inch hi-lok was in-
stalled.)
0.3246-0.32661BACB30NX10K( )XBOLT, PROTRUDING
HD
E
--1BACC30BH10COLLAR
Second oversize fastener.0.3402-0.34221BACB30NX10K( )YBOLT, PROTRUDING
HD
--1BACC30AC10COLLAR
First oversize fastener (if
5/16 inch bolt and nut was
installed.)
0.3276-0.32861BACB30US5K( )XBOLT, 12 PT HEAD
Under the bolt head.-1BACW10BP51CDWASHER, PLAIN
Under the nut.-1BACW10BP51DPWASHER, PLAIN
Torque nut to 243 to 258
inch lbs.
-1BACN10HR5CDNUT
FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 7 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
307 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 14

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.6401-0.64113BACB30MR10A26XBOLTF
Under the bolt head.-3BACW10BP101CDWASHER, PLAIN
Under the nut.-3BACW10BP101DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
Second oversize fastener.0.6557-0.65673BACB30MR10A26YBOLT
Under the bolt head.-3BACW10BP102CDWASHER, PLAIN
Under the nut.-3BACW10BP102DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
First oversize fastener.0.5776-0.57861BACB30US9K( )XBOLT, 12 PT HEADG
Under the bolt head.-1BACW10BP91ACWASHER, PLAIN AND
COUNTERSUNK
Self-aligning washer set.
Under the nut.
-1BACW10CA91CVWASHER
Self-aligning washer set.
Under the nut.
-1BACW10CA10CCWASHER
Between nut and self-
aligning washer, for grip
length adjustment.
-1BACW10BP91DPWASHER, PLAIN
Torque nut to 1746 to
1854 inch lbs.
-1BACN10HR9CDNUT
FIGURE 16: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 8 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
308 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 15 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
This Figure applies only to: Group 1, 3.
STA
783.04  FUSELAGE
UPPER DRAG  SKIN  FRONT SPAR
SPLICE ANGLE
LOWER DRAG  00  UNDERWING
SPLICE ANGLE  • LONGERON
FITTING
UNDERWING LONGERON FITTING
3054322
FIGURE 17: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 1 OF 8)
Original Issue: October 10, 2024
Export Controlled ECCN: 9E991  767-57A0148 RB
See page 1 for details  309 of 416

### Page 16 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
SEAL RETAINER
FRONT
SHIM "A"  B  SPAR  9 BATHTUB FITTING  INTERNAL  B
912 GIE  140~  ) SHIM "C"  1) 5) 6 16 LONGERON FITTING  UNDERWING
STA
776.21
9) SHIM "B"
26 ® 14  8 LOCATIONS
3 LOCATIONS  FWD  UNDERWING LONGERON  FITTING  RADIUS
A-A  FILLER 'B'
RADIUS
FILLER 'A
FWD
2 5 10 RADES  -ILLER "B'  RADIUS  FILLER "C"  34 LOCATIONS  8 15)
RADIUS
SHIM "D"  FILLER "D'
(2 LOCATIONS)  2)5
1 5 13
FILLER "A" 2€1  RADIUS
RADIUS
FILLER "E"\
RADIUS  FILLER "H"  RADIUS 25
FILLER "F"  B-B  FILLER "G"  RADIUS 2 G  3054324
FIGURE 17: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 2 OF 8)
Original Issue: October 10, 2024
767-57A0148 RB
Export Controlled ECCN: 9E991
See page 1 for details  310 of 416

### Page 17 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
RADIUS
RADIUS  25 7 RADIUS  ' FILLER "K"  FILLER "L"  260
FILLER "I"
FILLER J
FILLER 'O'  (5)
RADIUS
5 10) RADIUS  FILLER "M"  2 € 10 RADIUS,  FILLER "N"  FWD  FILLER "p"
C-C
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for one side of the airplane.
Step  Task  Name  Identification  Qty  More Data
Locate  FITTING, UNDER-  111T4020U13  1
WING LONGERON, LH
Locate  FITTING, INTERNAL  1
BATHTUB
Locate  SHIM, LAMINATED  BACS40R016B018F  1  (a) Shim A.
Locate  SHIM, LAMINATED  BACS40R020C032F  1  (a) Shim B.
Locate  SHIM, LAMINATED  BACS40R014C022F  1  (a) Shim C.
Locate  SHIM, LAMINATED  BACS40R025C063F  2  (a) (p) Shim D.
Locate  RADIUS FILLER  16  (0)
Drill  HOLE  (c)(d) Drill and ream
to final hole size.
Refer to the fastener
code table.
FIGURE 17: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 3 OF 8)
Original Issue: October 10, 2024
767-57A0148 RB
Export Controlled ECCN: 9E991
See page 1 for details  311 of 416

### Page 18

More DataQtyIdentificationNameTaskStep
(c)(d)(e) Drill and
ream to final hole
size. Refer to the
fastener code table.
42-HOLEDrill4
(f)16-RADIUS FILLERRemove / Keep5
Shim A.1BACS40R016B018FSHIM, LAMINATEDRemove / Keep
Shim B.1BACS40R020C032FSHIM, LAMINATEDRemove / Keep
Shim C.1BACS40R014C022FSHIM, LAMINATEDRemove / Keep
(p) Shim D.2BACS40R025C063FSHIM, LAMINATEDRemove / Keep
-1-FITTING, INTERNAL
BATHTUB
Remove / Keep
-1111T4020U13FITTING, UNDER-
WING LONGERON, LH
Remove / Keep
Clean and deburr all
structure.
--STRUCTUREClean/Deburr
(g)1111T4020U13FITTING, UNDER-
WING LONGERON, LH
Install (New)6
(h)12-RADIUS FILLERInstall (Kept)7
(i) Refer to the fas-
tener code table.
34-FASTENERInstall (New)8
(j) Shim A.1BACS40R016B018FSHIM, LAMINATEDInstall (Kept)9
(j) Shim B.1BACS40R020C032FSHIM, LAMINATEDInstall (Kept)
(j) Shim C.1BACS40R014C022FSHIM, LAMINATEDInstall (Kept)
(j)1-FITTING, INTERNAL
BATHTUB
Install (Kept)
-1-TEMPORARY TEN-
SION BOLT
Install (New)
(k)4-RADIUS FILLERInstall (Kept)10
(l) Refer to the fas-
tener code table.
8-FASTENERInstall (New)11
FIGURE 17: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 4 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
312 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 19

More DataQtyIdentificationNameTaskStep
-1-TEMPORARY TEN-
SION BOLT
Remove12
Ream and deburr
the tension bolt hole
to final hole size.
Refer to the fastener
code table.
1-HOLEReam
(l) Refer to the fas-
tener code table.
1-FASTENERInstall (New)
(p)(m) Shim D.2BACS40R025C063FSHIM, LAMINATEDInstall (Kept)13
(l)3-FASTENERInstall (New)14
(n)5 OzBMS 5-45SEALANTApply15
(o)5 OzBMS 5-95SEALANTApply16
(a) Peel the shim as required to get a maximum gap of 0.005 inch.
(b) If a radius filler was removed from locations "A" through "P". Locate in the recorded orientation from re-
moval.
(c) Keep a minimum of 1.7D edge margin at all fastener locations on the underwing longeron fitting.
(d) For existing fastener that is nominal, first, or second oversized, install the same type and size fastener if
open hole HFEC confirms crack-free condition.
(e) Oversizing to second oversize fastener requires high interference cold-working. Cold work the hole in
accordance with 767-200 SRM 51-40-09 or 767-200SF SRM 51-40-09 or 767-300 SRM 51-40-09 or 767-
300BCF SRM 51-40-09 or 767-300F SRM 51-40-09.
(f) If a radius filler was removed from locations "A" through "P". Record the orientation of the radius filler at
each location for re-installation.
(g) Apply BMS 5-95 faying surface seal to the mating surface of the lower panel and the underwing longeron
fitting. Refer to SOPM 20-50-19 as an accepted procedure.
(h) If a radius filler was removed from locations "C" through "L", "O", and "P". Locate in the recorded orientation
from removal.
(i) Install the fasteners wet with BMS 5-45 to partially install the underwing longeron fitting. Refer to SOPM
20-50-19, and 767-200 SRM 51-40-02 or 767-200SF SRM 51-40-02 or 767-300 SRM 51-40-02 or 767-
300BCF SRM 51-40-02 or 767-300F SRM 51-40-02 as accepted procedures.
Do not install fasteners common to the internal bathtub fitting or the three forward fasteners that are
common to the underwing longeron fitting.
(j) Apply BMS 5-45 faying surface seal. Refer to SOPM 20-50-19 as an accepted procedure.
(k) If a radius filler was removed from locations "A", "B", "M", and "N". Install in the recorded orientation.
(l) Install fasteners wet with BMS 5-45. Refer to SOPM 20-50-19 as an accepted procedure.
(m) Apply BMS 5-95 faying surface seal to each shim. Refer to SOPM 20-50-19 as an accepted procedure.
FIGURE 17: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 5 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
313 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 20

More DataQtyIdentificationNameTaskStep
(n) Apply cap seal to wing tank fasteners internally with BMS 5-45. Refer to 767 AMM 28-11-00 as an accepted
procedure.
(o) Apply BMS 5-95 to fillet seal around the perimeter of the underwing longeron fitting. Refer to SOPM 20-
50-19 as an accepted procedure.
(p) One or both Shim D may not have been previously installed. Install the necessary number of shim(s)
based on the findings during fitting removal. If shim(s) must be added at a location, use the appropriate
number of shim(s) as necessary.
The codes shown below agree with the letter shown in the upper left corner of the fastener symbols in the figure.
A number in the lower right corner gives the grip length of the fastener. The QTY numbers shown below are the
number of fasteners necessary for this figure.
More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.2621-0.264128BACB30NX8K( )XBOLT, PROTRUDING
HD
A
--28BACC30BH8COLLAR
Second oversize fastener.0.2777-0.279728BACB30NX8K( )YBOLT, PROTRUDING
HD
--28BACC30AC8COLLAR
First oversize fastener.0.3246-0.326611BACB30NX10K( )XBOLT, PROTRUDING
HD
B
--11BACC30BH10COLLAR
Second oversize fastener.0.3402-0.342211BACB30NX10K( )YBOLT, PROTRUDING
HD
--11BACC30AC10COLLAR
FIGURE 17: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 6 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
314 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 21

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.3871-0.38911BACB30NX12K( )XBOLT, PROTRUDING
HD
C
--1BACC30BH12COLLAR
Second oversize fastener.0.4027-0.40471BACB30NX12K( )YBOLT, PROTRUDING
HD
--1BACC30AC12COLLAR
First oversize fastener.0.4496-0.45161BACB30NX14K( )XBOLTD
--1BACC30BH14COLLAR
Second oversize fastener.0.4652-0.46721BACB30NX14K( )YBOLT
--1BACC30AC14COLLAR
First oversize fastener (if
5/16 inch hi-lok was in-
stalled.)
0.3246-0.32661BACB30NX10K( )XBOLT, PROTRUDING
HD
E
--1BACC30BH10COLLAR
Second oversize fastener.0.3402-0.34221BACB30NX10K( )YBOLT, PROTRUDING
HD
--1BACC30AC10COLLAR
First oversize fastener (if
5/16 inch bolt and nut was
installed.)
0.3276-0.32861BACB30US5K( )XBOLT, 12 PT HEAD
Under the bolt head.-1BACW10BP51CDWASHER, PLAIN
Under the nut.-1BACW10BP51DPWASHER, PLAIN
Torque nut to 243 to 258
inch lbs.
-1BACN10HR5CDNUT
First oversize fastener.0.6401-0.64113BACB30MR10A26XBOLTF
Under the bolt head.-3BACW10BP101CDWASHER, PLAIN
Under the nut.-3BACW10BP101DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
Second oversize fastener.0.6557-0.65673BACB30MR10A26YBOLT
Under the bolt head.-3BACW10BP102CDWASHER, PLAIN
Under the nut.-3BACW10BP102DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
FIGURE 17: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 7 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
315 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 22

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.5776-0.57861BACB30US9K( )XBOLT, 12 PT HEADG
Under the bolt head.-1BACW10BP91ACWASHER, PLAIN AND
COUNTERSUNK
Self-aligning washer set.
Under the nut.
-1BACW10CA91CVWASHER
Self-aligning washer set.
Under the nut.
-1BACW10CA10CCWASHER
Between nut and self-
aligning washer, for grip
length adjustment.
-1BACW10BP91DPWASHER, PLAIN
Torque nut to 1746 to
1854 inch lbs.
-1BACN10HR9CDNUT
FIGURE 17: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 8 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
316 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 23 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
This Figure applies only to: Group 1, 3.
STA
FUSELAGE  783.04
FRONT SPAR  SKIN  UPPER DRAG
SPLICE ANGLE
UNDERWING  LOWER DRAG
LONGERON  SPLICE ANGLE
FITTING
UNDERWING LONGERON FITTING
3054601
FIGURE 18: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U14 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 1 OF 8)
Original Issue: October 10, 2024
Export Controlled ECCN: 9E991  767-57A0148 RB
See page 1 for details  317 of 416

### Page 24 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
SEAL RETAINER
FRONT
BATHTUB FITTING 1S  INTERNAL  SPAR  B  SHIM "A"
050
LONGERON FITTING  UNDERWING 15 616  * Ou
STA
776.21
+  +
SHIM "B"
8 LOCATIONS  11A 126
UNDERWING LONGERON
FITTING  FWD  3 LOCATIONS
FILLER 'B'  RADIUS  A-A
RADIUS
FILLER'A'
+ +
FWD  FILLER "B"  RADIUS  eto eta 2E
34 LOCATIONS  RADIUS  (2)5  125 BLE
15)  FILLER "C'
RADIUS
FILLER "D"  SHIM "D"
(2 LOCATIONS)
1 € 13)
-ILLER A'
BIF  5(7  ' FILLER "E"  RADIUS
5)U  (2) 5)
12  FILLER "H"  RADIUS  RADIUS  RADIUS  FILLER "F"  3054602
FILLER "G"  B-B
FIGURE 18: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U14 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 2 OF 8)
Original Issue: October 10, 2024
767-57A0148 RB
Export Controlled ECCN: 9E991
See page 1 for details  318 of 416

### Page 25 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
RADIUS
RADIUS  FILLER "K"  RADIUS
FILLER "L"  250  RADIOS  FILLER "|"
FILLER "J"  5
RADIUS  RADIUS
FILLER "P"  FILLER "O"
₴ 5 10
FWD  RADIUS  5  10
FILLER "N"
RADIUS
C-C  FILLER "M"
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for one side of the airplane.
Step  Task  Name  Identification  Qty  More Data
1  Locate  FITTING, UNDER-  111T4020U14  1
WING LONGERON,
RH
Locate  FITTING, INTERNAL  1
BATHTUB
Locate  SHIM, LAMINATED  BACS40R016B018F  1  (a) Shim A.
Locate  SHIM, LAMINATED  BACS40R020C032F  1  (a) Shim B.
Locate  SHIM, LAMINATED  BACS40R014C022F  1  (a) Shim C.
Locate  SHIM, LAMINATED  BACS40R025C063F  2  (a) (p) Shim D.
2  Locate  RADIUS FILLER  16  (b)
Drill  HOLE  3  (c)(d) Drill and ream
to final hole size.
Refer to the fastener
code table.
FIGURE 18: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020014 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 3 OF 8)
Original Issue: October 10, 2024
Export Controlled ECCN: 9E991  767-57A0148 RB
See page 1 for details  319 of 416

### Page 26

More DataQtyIdentificationNameTaskStep
(c)(d)(e) Drill and
ream to final hole
size. Refer to the
fastener code table.
42-HOLEDrill4
(f)16-RADIUS FILLERRemove / Keep5
Shim A.1BACS40R016B018FSHIM, LAMINATEDRemove / Keep
Shim B.1BACS40R020C032FSHIM, LAMINATEDRemove / Keep
Shim C.1BACS40R014C022FSHIM, LAMINATEDRemove / Keep
(p) Shim D.2BACS40R025C063FSHIM, LAMINATEDRemove / Keep
-1-FITTING, INTERNAL
BATHTUB
Remove / Keep
-1111T4020U14FITTING, UNDER-
WING LONGERON,
RH
Remove / Keep
Clean and deburr all
structure.
--STRUCTUREClean/Deburr
(g)1111T4020U14FITTING, UNDER-
WING LONGERON,
RH
Install (New)6
(h)12-RADIUS FILLERInstall (Kept)7
(i) Refer to the fas-
tener code table.
34-FASTENERInstall (New)8
(j) Shim A.1BACS40R016B018FSHIM, LAMINATEDInstall (Kept)9
(j) Shim B.1BACS40R020C032FSHIM, LAMINATEDInstall (Kept)
(j) Shim C.1BACS40R014C022FSHIM, LAMINATEDInstall (Kept)
(j)1-FITTING, INTERNAL
BATHTUB
Install (Kept)
-1-TEMPORARY TEN-
SION BOLT
Install (New)
(k)4-RADIUS FILLERInstall (Kept)10
(l) Refer to the fas-
tener code table.
8-FASTENERInstall (New)11
FIGURE 18: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U14 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 4 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
320 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 27

More DataQtyIdentificationNameTaskStep
-1-TEMPORARY TEN-
SION BOLT
Remove12
Ream and deburr
the tension bolt hole
to final hole size.
Refer to the fastener
code table.
1-HOLEReam
(l) Refer to the fas-
tener code table.
1-FASTENERInstall (New)
(m)(p) Shim D.2BACS40R025C063FSHIM, LAMINATEDInstall (Kept)13
(l)3-FASTENERInstall (New)14
(n)5 OzBMS 5-45SEALANTApply15
(o)5 OzBMS 5-95SEALANTApply16
(a) Peel the shim as required to get a maximum gap of 0.005 inch.
(b) If a radius filler was removed from locations "A" through "P". Locate in the recorded orientation from re-
moval.
(c) Keep a minimum of 1.7D edge margin at all fastener locations on the underwing longeron fitting.
(d) For existing fastener that is nominal, first, or second oversized, install the same type and size fastener if
open hole HFEC confirms crack-free condition.
(e) Oversizing to second oversize fastener requires high interference cold-working. Cold work the hole in
accordance with 767-200 SRM 51-40-09 or 767-200SF SRM 51-40-09 or 767-300 SRM 51-40-09 or 767-
300BCF SRM 51-40-09 or 767-300F SRM 51-40-09.
(f) If a radius filler was removed from locations "A" through "P". Record the orientation of the radius filler at
each location for re-installation.
(g) Apply BMS 5-95 faying surface seal to the mating surface of the lower panel and the underwing longeron
fitting. Refer to SOPM 20-50-19 as an accepted procedure.
(h) If a radius filler was removed from locations "C" through "L", "O", and "P". Locate in the recorded orientation
from removal.
(i) Install the fasteners wet with BMS 5-45 to partially install the underwing longeron fitting. Refer to SOPM
20-50-19, and 767-200 SRM 51-40-02 or 767-200SF SRM 51-40-02 or 767-300 SRM 51-40-02 or 767-
300BCF SRM 51-40-02 or 767-300F SRM 51-40-02 as accepted procedures.
Do not install fasteners common to the internal bathtub fitting or the three forward fasteners that are
common to the underwing longeron fitting.
(j) Apply BMS 5-45 faying surface seal. Refer to SOPM 20-50-19 as an accepted procedure.
(k) If a radius filler was removed from locations "A", "B", "M", and "N". Install in the recorded orientation.
(l) Install fasteners wet with BMS 5-45. Refer to SOPM 20-50-19 as an accepted procedure.
(m) Apply BMS 5-95 faying surface seal to each shim. Refer to SOPM 20-50-19 as an accepted procedure.
FIGURE 18: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U14 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 5 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
321 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 28

More DataQtyIdentificationNameTaskStep
(n) Apply cap seal to wing tank fasteners internally with BMS 5-45. Refer to 767 AMM 28-11-00 as an accepted
procedure.
(o) Apply BMS 5-95 to fillet seal around the perimeter of the underwing longeron fitting. Refer to SOPM 20-
50-19 as an accepted procedure.
(p) One or both Shim D may not have been previously installed. Install the necessary number of shim(s)
based on the findings during fitting removal. If shim(s) must be added at a location, use the appropriate
number of shim(s) as necessary.
The codes shown below agree with the letter shown in the upper left corner of the fastener symbols in the figure.
A number in the lower right corner gives the grip length of the fastener. The QTY numbers shown below are the
number of fasteners necessary for this figure.
More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.2621-0.264128BACB30NX8K( )XBOLT, PROTRUDING
HD
A
--28BACC30BH8COLLAR
Second oversize fastener.0.2777-0.279728BACB30NX8K( )YBOLT, PROTRUDING
HD
--28BACC30AC8COLLAR
First oversize fastener.0.3246-0.326611BACB30NX10K( )XBOLT, PROTRUDING
HD
B
---BACC30BH10COLLAR
Second oversize fastener.0.3402-0.342211BACB30NX10K( )YBOLT, PROTRUDING
HD
--11BACC30AC10COLLAR
FIGURE 18: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U14 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 6 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
322 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 29

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.3871-0.38911BACB30NX12K( )XBOLT, PROTRUDING
HD
C
---BACC30BH12COLLAR
Second oversize fastener.0.4027-0.40471BACB30NX12K( )YBOLT, PROTRUDING
HD
--1BACC30AC12COLLAR
First oversize fastener.0.4496-0.45161BACB30NX14K( )XBOLTD
--1BACC30BH14COLLAR
Second oversize fastener.0.4652-0.46721BACB30NX14K( )YBOLT
--1BACC30AC14COLLAR
First oversize fastener (if
5/16 inch hi-lok was in-
stalled.)
0.3246-0.32661BACB30NX10K( )XBOLT, PROTRUDING
HD
E
--1BACC30BH10COLLAR
Second oversize fastener.0.3402-0.34221BACB30NX10K( )YBOLT, PROTRUDING
HD
--1BACC30AC10COLLAR
First oversize fastener (if
5/16 inch bolt and nut was
installed.)
0.3276-0.32861BACB30US5K( )XBOLT, 12 PT HEAD
Under the bolt head.-1BACW10BP51CDWASHER, PLAIN
Under the nut.-1BACW10BP51DPWASHER, PLAIN
Torque nut to 243 to 258
inch lbs.
-1BACN10HR5CDNUT
First oversize fastener.0.6401-0.64113BACB30MR10A26XBOLTF
Under the bolt head.-3BACW10BP101CDWASHER, PLAIN
Under the nut.-3BACW10BP101DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
Second oversize fastener.0.6557-0.65673BACB30MR10A26YBOLT
Under the bolt head.-3BACW10BP102CDWASHER, PLAIN
Under the nut.-3BACW10BP102DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
FIGURE 18: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U14 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 7 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
323 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 30

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.5776-0.57861BACB30US9K( )XBOLT, 12 PT HEADG
Under the bolt head.-1BACW10BP91ACWASHER, PLAIN AND
COUNTERSUNK
Self-aligning washer set.
Under the nut.
-1BACW10CA91CVWASHER
Self-aligning washer set.
Under the nut.
-1BACW10CA10CCWASHER
Between nut and self-
aligning washer, for grip
length adjustment.
-1BACW10BP91DPWASHER, PLAIN
Torque nut to 1746 to
1854 inch lbs.
-1BACN10HR9CDNUT
FIGURE 18: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U14 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 8 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
324 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 31 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
This Figure applies only to: Group 4, 6-7.
STA
783.04  FUSELAGE
UPPER DRAG  SKIN  FRONT SPAR
SPLICE ANGLE
LOWER DRAG  UNDERWING
SPLICE ANGLE  LONGERON
FITTING
UNDERWING LONGERON FITTING
3054345
FIGURE 19: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 1 OF 9)
Original Issue: October 10, 2024
Export Controlled ECCN: 9E991
See page 1 for details  325 of 416

### Page 32 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
FILLER "R"  RADIUS  SEAL RETAINER
FRONT
115  SHIM "A" B  SPAR  GO BATHTUB FITTING  B
9  GN  40  › SHIM "C"  15 € 16  UNDERWING  LONGERON FITTING
STA
776.21
+  + C
9) SHIMS "B"
26 (3) 14  8 LOCATIONS
3 LOCATIONS  FWD  UNDERWING LONGERON  FITTING  RADIUS
A-A  FILLER 'B'
RADIUS
FILLER 'A'
D  RADIUS  FWD
FILLER "B"
251  RADIUS  34 LOCATIONS
FILLER "C"  15
22
RADIUS
SHIM "D"  FILLER "D"
(2 LOCATIONS)  250
1 5 13
FILLER "A" 35  RADIUS
FILLER "EM 2E7  RADIUS
19  20  RADIUS  FILLER "F"  RADIUS  3054347
FILLER "H"
B-B  FILLER "G"  RADIUS
FIGURE 19: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 2 OF 9)
Original Issue: October 10, 2024
767-57A0148 RB
Export Controlled ECCN: 9E991
See page 1 for details  326 of 416

### Page 33 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
RADIUS
FILLER "L"
RADIUS  FILLER K  25U
FILLER "I"  257) FAER  FILLER J
FILLER "O  (5X
RADIUS
5 10) RADIUS  FILLER "M"  2 5 10 RADIUS  FILLER "N"  FWD  FILLER "P"
C-C
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for one side of the airplane.
Step  Task  Name  Identification  Qty  More Data
Locate  FITTING, UNDER-  111T4020U7  1
WING LONGERON, LH
Locate  FITTING, INTERNAL  1
BATHTUB
Locate  SHIM, LAMINATED  BACS40R016B018F  1  (a) Shim A.
Locate  SHIM, LAMINATED  BACS40R020C032F  1  (a) Shim B.
Locate  SHIM, LAMINATED  BACS40R014C022F  1  (a) Shim C.
Locate  SHIM, LAMINATED  BACS40R025C063F  2  (a) (q) Shim D.
Locate  RADIUS FILLER  16  (b)
Drill  HOLE  (c)(d) Drill and ream
to final hole size.
Refer to the fastener
code table.
FIGURE 19: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 3 OF 9)
Original Issue: October 10, 2024
767-57A0148 RB
Export Controlled ECCN: 9E991
See page 1 for details  327 of 416

### Page 34

More DataQtyIdentificationNameTaskStep
(c)(d)(e) Drill and
ream to final hole
size. Refer to the
fastener code table.
42-HOLEDrill4
(f)16-RADIUS FILLERRemove / Keep5
Shim A.1BACS40R016B018FSHIM, LAMINATEDRemove / Keep
Shim B.1BACS40R020C032FSHIM, LAMINATEDRemove / Keep
Shim C.1BACS40R014C022FSHIM, LAMINATEDRemove / Keep
(q) Shim D.2BACS40R025C063FSHIM, LAMINATEDRemove / Keep
-1-FITTING, INTERNAL
BATHTUB
Remove / Keep
-1111T4020U7FITTING, UNDER-
WING LONGERON, LH
Remove / Keep
Clean and deburr all
structure.
--STRUCTUREClean/Deburr
(g)1111T4020U7FITTING, UNDER-
WING LONGERON, LH
Install (New)6
(h)12-RADIUS FILLERInstall (Kept)7
(i) Refer to the fas-
tener code table.
34-FASTENERInstall (New)8
(j) Shim A.1BACS40R016B018FSHIM, LAMINATEDInstall (Kept)9
(j) Shim B.1BACS40R020C032FSHIM, LAMINATEDInstall (Kept)
(j) Shim C.1BACS40R014C022FSHIM, LAMINATEDInstall (Kept)
(j)1-FITTING, INTERNAL
BATHTUB
Install (Kept)
(k) Radius filler R.
Refer to the fastener
code table for stack-
up.
1140T0120-48SHIMInstall (New)
-1-TEMPORARY TEN-
SION BOLT
Install (New)
(l)4-RADIUS FILLERInstall (Kept)10
(m) Refer to the fas-
tener code table.
8-FASTENERInstall (New)11
FIGURE 19: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 4 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
328 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 35

More DataQtyIdentificationNameTaskStep
-1-TEMPORARY TEN-
SION BOLT
Remove12
Ream and deburr
the tension bolt hole
to final hole size.
Refer to the fastener
code table.
1-HOLEReam
(m) Refer to the fas-
tener code table.
1-FASTENERInstall (New)
(n)(q) Shim D.2BACS40R025C063FSHIM, LAMINATEDInstall (Kept)13
(m)3-FASTENERInstall (New)14
(o)5 OzBMS 5-45SEALANTApply15
(p)5 OzBMS 5-95SEALANTApply16
(a) Peel the shim as required to get a maximum gap of 0.005 inch.
(b) If a radius filler was removed from locations "A" through "P". Locate in the recorded orientation from re-
moval.
(c) Keep a minimum of 1.7D edge margin at all fastener locations on the underwing longeron fitting.
(d) For existing fastener that is nominal, first, or second oversized, install the same type and size fastener if
open hole HFEC confirms crack-free condition.
(e) Oversizing to second oversize fastener requires high interference cold-working. Cold work the hole in
accordance with 767-200 SRM 51-40-09 or 767-200SF SRM 51-40-09 or 767-300 SRM 51-40-09 or 767-
300BCF SRM 51-40-09 or 767-300F SRM 51-40-09.
(f) If a radius filler was removed from locations "A" through "P". Record the orientation of the radius filler at
each location for re-installation.
(g) Apply BMS 5-95 faying surface seal to the mating surface of the lower panel and the underwing longeron
fitting. Refer to SOPM 20-50-19 as an accepted procedure.
(h) If a radius filler was removed from locations "C" through "L", "O", and "P". Locate in the recorded orientation
from removal.
(i) Install the fasteners wet with BMS 5-45 to partially install the underwing longeron fitting. Refer to SOPM
20-50-19, and 767-200 SRM 51-40-02 or 767-200SF SRM 51-40-02 or 767-300 SRM 51-40-02 or 767-
300BCF SRM 51-40-02 or 767-300F SRM 51-40-02 as accepted procedures.
Do not install fasteners common to the internal bathtub fitting or the three forward fasteners that are
common to the underwing longeron fitting.
(j) Apply BMS 5-45 faying surface seal. Refer to SOPM 20-50-19 as an accepted procedure.
(k) As an option use kept shim for internal bathtub fitting, if installed.
(l) If a radius filler was removed from locations "A", "B", "M", and "N". Install in the recorded orientation.
(m) Install fasteners wet with BMS 5-45. Refer to SOPM 20-50-19 as an accepted procedure.
FIGURE 19: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 5 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
329 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 36

More DataQtyIdentificationNameTaskStep
(n) Apply BMS 5-95 faying surface seal to each shim. Refer to SOPM 20-50-19 as an accepted procedure.
(o) Apply cap seal to wing tank fasteners internally with BMS 5-45. Refer to 767 AMM 28-11-00 as an accepted
procedure.
(p) Apply BMS 5-95 to fillet seal around the perimeter of the underwing longeron fitting. Refer to SOPM 20-
50-19 as an accepted procedure.
(q) One or both Shim D may not have been previously installed. Install the necessary number of shim(s)
based on the findings during fitting removal. If shim(s) must be added at a location, use the appropriate
number of shim(s) as necessary.
The flag note numbers shown below agree with the numbers shown in the flag symbols in the figure.
More DataFlag Note
Install head on near side.1
Install head on far side.2
The codes shown below agree with the letter shown in the upper left corner of the fastener symbols in the figure.
A number in the lower right corner gives the grip length of the fastener. The QTY numbers shown below are the
number of fasteners necessary for this figure.
More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.2621-0.264128BACB30NX8K( )XBOLT, PROTRUDING
HD
A
--28BACC30BH8COLLAR
Second oversize fastener.0.2777-0.279728BACB30NX8K( )YBOLT, PROTRUDING
HD
--28BACC30AC8COLLAR
FIGURE 19: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 6 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
330 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 37

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.3246-0.326610BACB30NX10K( )XBOLT, PROTRUDING
HD
B
--10BACC30BH10COLLAR
Second oversize fastener.0.3402-0.342210BACB30NX10K( )YBOLT, PROTRUDING
HD
--10BACC30AC10COLLAR
First oversize fastener.0.3871-0.38911BACB30NX12K( )XBOLT, PROTRUDING
HD
C
--1BACC30BH12COLLAR
Second oversize fastener.0.4027-0.40471BACB30NX12K( )YBOLT, PROTRUDING
HD
--1BACC30AC12COLLAR
First oversize fastener (if
5/16 inch hi-lok was in-
stalled.)
0.3246-0.32662BACB30NX10K( )XBOLT, PROTRUDING
HD
D
--2BACC30BH10COLLAR
Second oversize fastener.0.3402-0.34222BACB30NX10K( )YBOLT, PROTRUDING
HD
--2BACC30AC10COLLAR
First oversize fastener (if
5/16 inch bolt and nut was
installed.)
0.3276-0.32862BACB30US5K( )XBOLT, 12 PT HEAD
Under the bolt head.-2BACW10BP51CDWASHER, PLAIN
Under the nut.-2BACW10BP51DPWASHER, PLAIN
Torque nut to 243 to 258
inch lbs.
-2BACN10HR5CDNUT
FIGURE 19: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 7 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
331 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 38

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.6401-0.64113BACB30MR10A26XBOLTE
Under the bolt head.-3BACW10BP101CDWASHER, PLAIN
Under the nut.-3BACW10BP101DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
Second oversize fastener.0.6557-0.65673BACB30MR10A26YBOLT
Under the bolt head.-3BACW10BP102CDWASHER, PLAIN
Under the nut.-3BACW10BP102DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
First oversize fastener. If
3/8 inch fastener was in-
stalled.
0.3871-0.38911BACB30NX12K( )XBOLT, PROTRUDING
HD
F
--1BACC30BH12COLLAR
Second oversize fastener.0.4027-0.40471BACB30NX12K( )YBOLT, PROTRUDING
HD
--1BACC30AC12COLLAR
First oversize fastener. If
7/16 inch fastener was in-
stalled.
0.4496-0.45161BACB30NX14K( )XBOLT
--1BACC30BH14COLLAR
Second oversize fastener.0.4652-0.46721BACB30NX14K( )YBOLT
--1BACC30AC14COLLAR
FIGURE 19: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 8 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
332 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 39

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.5776-0.57861BACB30US9K( )XBOLT, 12 PT HEADG
Under the bolt head.-1BACW10BP91ACWASHER, PLAIN AND
COUNTERSUNK
Self-aligning washer set.
Under the head.
-1BACW10CA91CVWASHER
Self-aligning washer set.
Under the head.
-1BACW10CA10CCWASHER
Radius filler "R" under nut,
adjacent to bathtub fitting.
-1140T0120-48SHIM
Self-aligning washer set.
Under the nut.
-1BACW10CA91CVWASHER
Self-aligning washer set.
Under the nut.
-1BACW10CA10CCWASHER
Between nut and self-
aligning washer, for grip
length adjustment.
-1BACW10BP91DPWASHER, PLAIN
Torque nut to 1746 to
1854 inch lbs.
-1BACN10HR9CDNUT
FIGURE 19: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U7 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 9 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
333 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 40 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
This Figure applies only to: Group 4, 6-7.
STA
FUSELAGE  783.04
FRONT SPAR  SKIN  UPPER DRAG
SPLICE ANGLE
UNDERWING  LOWER DRAG
LONGERON  SPLICE ANGLE
FITTING
UNDERWING LONGERON FITTING
3054659
FIGURE 20: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 1 OF 9)
Original Issue: October 10, 2024
767-57A0148 RB
Export Controlled ECCN: 9E991
See page 1 for details  334 of 416

### Page 41 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
SEAL RETAINER  FILLER "R"  RADIUS
NTERNAL  (9)  FRONT  SPAR  SHIM "A"
050
LONGERON FITTING  UNDERWING 15€16  SHIM "C" UXEX
STA
776.21
SHIMS "B" (
8 LOCATIONS  UNDERWING LONGERON  11L 126
FITTING  FWD  3 LOCATIONS
RADIUS
FILLER 'B'  A-A
RADIUS
FILLER'A'
+ ++
RADIUS  His etto s
FILLER "B"
34 LOCATIONS  RADIUS  BIN
FILLER "C"
(5)
RADIUS  A F
FILLER "D"  SHIM "D"
(2 LOCATIONS)
5 13
2OD BALES®  FILLER "A"
5T RADIUS  FILLER "E"
5
RADIUS  RADIUS 2€J  FILLER "F"  RADIUS  20  21
FILLER "H"  FWD
FILLER "G"  B-B
FIGURE 20: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 2 OF 9)
Original Issue: October 10, 2024
Export Controlled ECCN: 9E991  767-57A0148 RB
See page 1 for details  335 of 416

### Page 42 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
RADIUS  RADIUS
FILLER "L"  RADIUS 2  FILLER "I"
(2) 5)  FILLER "K"  (2)5
FILLER "J"  RADIUS 2E
FILLER "O"  RADIUS (2) 5)T
RADIUS
FILLER "P"  FWD  251
RADIUS  2)5
FILLER "N"  RADIUS  3054664
C-C  FILLER "M"
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for one side of the airplane.
Step  Task  Name  Identification  Qty  More Data
1  Locate  FITTING, UNDER-  111T4020U8  1
WING LONGERON,
RH
Locate  FITTING, INTERNAL  1
BATHTUB
Locate  SHIM, LAMINATED  BACS40R016B018F  1  (a) Shim A.
Locate  SHIM, LAMINATED  BACS40R020C032F  1  (a) Shim B.
Locate  SHIM, LAMINATED  BACS40R014C022F  1  (a) Shim C.
Locate  SHIM, LAMINATED  BACS40R025C063F  2  (a) (q) Shim D.
2  Locate  RADIUS FILLER  16  (b)
Drill  HOLE  3  (c)(d) Drill and ream
to final hole size.
Refer to the fastener
code table.
FIGURE 20: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 3 OF 9)
Original Issue: October 10, 2024
767-57A0148 RB
Export Controlled ECCN: 9E991
See page 1 for details  336 of 416

### Page 43

More DataQtyIdentificationNameTaskStep
(c)(d)(e) Drill and
ream to final hole
size. Refer to the
fastener code table.
42-HOLEDrill4
(f)16-RADIUS FILLERRemove / Keep5
Shim A.1BACS40R016B018FSHIM, LAMINATEDRemove / Keep
Shim B.1BACS40R020C032FSHIM, LAMINATEDRemove / Keep
Shim C.1BACS40R014C022FSHIM, LAMINATEDRemove / Keep
(q) Shim D.2BACS40R025C063FSHIM, LAMINATEDRemove / Keep
-1-FITTING, INTERNAL
BATHTUB
Remove / Keep
-1111T4020U8FITTING, UNDER-
WING LONGERON,
RH
Remove / Keep
Clean and deburr all
structure.
--STRUCTUREClean/Deburr
(g)1111T4020U8FITTING, UNDER-
WING LONGERON,
RH
Install (New)6
(h)12-RADIUS FILLERInstall (Kept)7
(i) Refer to the fas-
tener code table.
34-FASTENERInstall (New)8
(j) Shim A.1BACS40R016B018FSHIM, LAMINATEDInstall (Kept)9
(j) Shim B.1BACS40R020C032FSHIM, LAMINATEDInstall (Kept)
(j) Shim C.1BACS40R014C022FSHIM, LAMINATEDInstall (Kept)
(j)1-FITTING, INTERNAL
BATHTUB
Install (Kept)
(k) Radius filler R.
Refer to the fastener
code table for stack-
up.
1140T0120-48SHIMInstall (New)
-1-TEMPORARY TEN-
SION BOLT
Install (New)
(l)4-RADIUS FILLERInstall (Kept)10
(m) Refer to the fas-
tener code table.
8-FASTENERInstall (New)11
FIGURE 20: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 4 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
337 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 44

More DataQtyIdentificationNameTaskStep
-1-TEMPORARY TEN-
SION BOLT
Remove12
Ream and deburr
the tension bolt hole
to final hole size.
Refer to the fastener
code table.
1-HOLEReam
(m) Refer to the fas-
tener code table.
1-FASTENERInstall (New)
(n)(q) Shim D.2BACS40R025C063FSHIM, LAMINATEDInstall (Kept)13
(m)3-FASTENERInstall (New)14
(o)5 OzBMS 5-45SEALANTApply15
(p)5 OzBMS 5-95SEALANTApply16
(a) Peel the shim as required to get a maximum gap of 0.005 inch.
(b) If a radius filler was removed from locations "A" through "P". Locate in the recorded orientation from re-
moval.
(c) Keep a minimum of 1.7D edge margin at all fastener locations on the underwing longeron fitting.
(d) For existing fastener that is nominal, first, or second oversized, install the same type and size fastener if
open hole HFEC confirms crack-free condition.
(e) Oversizing to second oversize fastener requires high interference cold-working. Cold work the hole in
accordance with 767-200 SRM 51-40-09 or 767-200SF SRM 51-40-09 or 767-300 SRM 51-40-09 or 767-
300BCF SRM 51-40-09 or 767-300F SRM 51-40-09.
(f) If a radius filler was removed from locations "A" through "P". Record the orientation of the radius filler at
each location for re-installation.
(g) Apply BMS 5-95 faying surface seal to the mating surface of the lower panel and the underwing longeron
fitting. Refer to SOPM 20-50-19 as an accepted procedure.
(h) If a radius filler was removed from locations "C" through "L", "O", and "P". Locate in the recorded orientation
from removal.
(i) Install the fasteners wet with BMS 5-45 to partially install the underwing longeron fitting. Refer to SOPM
20-50-19, and 767-200 SRM 51-40-02 or 767-200SF SRM 51-40-02 or 767-300 SRM 51-40-02 or 767-
300BCF SRM 51-40-02 or 767-300F SRM 51-40-02 as accepted procedures.
Do not install fasteners common to the internal bathtub fitting or the three forward fasteners that are
common to the underwing longeron fitting.
(j) Apply BMS 5-45 faying surface seal. Refer to SOPM 20-50-19 as an accepted procedure.
(k) As an option use kept shim for internal bathtub fitting, if installed.
(l) If a radius filler was removed from locations "A", "B", "M", and "N". Install in the recorded orientation.
(m) Install fasteners wet with BMS 5-45. Refer to SOPM 20-50-19 as an accepted procedure.
FIGURE 20: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 5 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
338 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 45

More DataQtyIdentificationNameTaskStep
(n) Apply BMS 5-95 faying surface seal to each shim. Refer to SOPM 20-50-19 as an accepted procedure.
(o) Apply cap seal to wing tank fasteners internally with BMS 5-45. Refer to 767 AMM 28-11-00 as an accepted
procedure.
(p) Apply BMS 5-95 to fillet seal around the perimeter of the underwing longeron fitting. Refer to SOPM 20-
50-19 as an accepted procedure.
(q) One or both Shim D may not have been previously installed. Install the necessary number of shim(s)
based on the findings during fitting removal. If shim(s) must be added at a location, use the appropriate
number of shim(s) as necessary.
The flag note numbers shown below agree with the numbers shown in the flag symbols in the figure.
More DataFlag Note
Install head on near side.1
Install head on far side.2
The codes shown below agree with the letter shown in the upper left corner of the fastener symbols in the figure.
A number in the lower right corner gives the grip length of the fastener. The QTY numbers shown below are the
number of fasteners necessary for this figure.
More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.2621-0.264128BACB30NX8K( )XBOLT, PROTRUDING
HD
A
--28BACC30BH8COLLAR
Second oversize fastener.0.2777-0.279728BACB30NX8K( )YBOLT, PROTRUDING
HD
--28BACC30AC8COLLAR
FIGURE 20: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 6 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
339 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 46

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.3246-0.326611BACB30NX10K( )XBOLT, PROTRUDING
HD
B
--11BACC30BH10COLLAR
Second oversize fastener.0.3402-0.342211BACB30NX10K( )YBOLT, PROTRUDING
HD
--11BACC30AC10COLLAR
First oversize fastener.0.3871-0.38911BACB30NX12K( )XBOLT, PROTRUDING
HD
C
--1BACC30BH12COLLAR
Second oversize fastener.0.4027-0.40471BACB30NX12K( )YBOLT, PROTRUDING
HD
--1BACC30AC12COLLAR
First oversize fastener (if
5/16 inch hi-lok was in-
stalled.)
0.3246-0.32661BACB30NX10K( )XBOLT, PROTRUDING
HD
D
--1BACC30BH10COLLAR
Second oversize fastener.0.3402-0.34221BACB30NX10K( )YBOLT, PROTRUDING
HD
--1BACC30AC10COLLAR
First oversize fastener (if
5/16 inch bolt and nut was
installed.)
0.3276-0.32861BACB30US5K( )XBOLT, 12 PT HEAD
Under the bolt head.-1BACW10BP51CDWASHER, PLAIN
Under the nut.-1BACW10BP51DPWASHER, PLAIN
Torque nut to 243 to 258
inch lbs.
-1BACN10HR5CDNUT
FIGURE 20: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 7 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
340 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 47

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.6401-0.64113BACB30MR10A26XBOLTE
Under the bolt head.-3BACW10BP101CDWASHER, PLAIN
Under the nut.-3BACW10BP101DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
Second oversize fastener.0.6557-0.65673BACB30MR10A26YBOLT
Under the bolt head.-3BACW10BP102CDWASHER, PLAIN
Under the nut.-3BACW10BP102DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
First oversize fastener. If
3/8 inch fastener was in-
stalled.
0.3871-0.38911BACB30NX12K( )XBOLT, PROTRUDING
HD
F
--1BACC30BH12COLLAR
Second oversize fastener.0.4027-0.40471BACB30NX12K( )YBOLT, PROTRUDING
HD
--1BACC30AC12COLLAR
First oversize fastener. If
7/16 inch fastener was in-
stalled.
0.4496-0.45161BACB30NX14K( )XBOLT
--1BACC30BH14COLLAR
Second oversize fastener.0.4652-0.46721BACB30NX14K( )YBOLT
--1BACC30AC14COLLAR
FIGURE 20: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 8 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
341 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 48

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.5776-0.57861BACB30US9K( )XBOLT, 12 PT HEADG
Under the bolt head.-1BACW10BP91ACWASHER, PLAIN AND
COUNTERSUNK
Self-aligning washer set.
Under the head.
-1BACW10CA91CVWASHER
Self-aligning washer set.
Under the head.
-1BACW10CA10CCWASHER
Radius filler "R" under nut,
adjacent to bathtub fitting.
-1140T0120-48SHIM
Self-aligning washer set.
Under the nut.
-1BACW10CA91CVWASHER
Self-aligning washer set.
Under the nut.
-1BACW10CA10CCWASHER
Between nut and self-
aligning washer, for grip
length adjustment.
-1BACW10BP91DPWASHER, PLAIN
Torque nut to 1746 to
1854 inch lbs.
-1BACN10HR9CDNUT
FIGURE 20: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U8 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 9 OF 9)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
342 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 49 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
This Figure applies only to: Group 4, 6-7.
STA
783.04  FUSELAGE
UPPER DRAG  SKIN  FRONT SPAR
SPLICE ANGLE
LOWER DRAG  UNDERWING
SPLICE ANGLE  LONGERON
FITTING
UNDERWING LONGERON FITTING
3054357
FIGURE 21: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 1 OF 8)
Original Issue: October 10, 2024
Export Controlled ECCN: 9E991  767-57A0148 RB
See page 1 for details  343 of 416

### Page 50 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
RADIUS
FILLER "R"  SEAL RETAINER
FRONT
SHIM  SPAR  5) BATHTUB FITTING  INTERNAL  B
912 N  9) SHIM "C"  1X5) 6 16) UNDERWING
LONGERON FITTING
STA
776.21
9 ) SHIMS "B"
F1 26 3 14  8 LOCATIONS
3 LOCATIONS  FWD  UNDERWING LONGERON  FITTING  RADIUS
A-A  FILLER 'B'
RADIUS
FILLER 'A
FWD
2)  5 10) RADIUS  -ILLER "B'  RADIUS  34 LOCATIONS
FILLER 'C"
RADIUS
SHIM "D"  FILLER "D'
(2 LOCATIONS)
1 € 13
FILLER "A " 2510  RADIUS
RADIUS
PILLER "E"  215/7
RADIUS  FILLERS AG
FILLER "F"  B-B  FILLER "G"  RADIUS 25  3054365
FIGURE 21: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 2 OF 8)
Original Issue: October 10, 2024
767-57A0148 RB
Export Controlled ECCN: 9E991
See page 1 for details  344 of 416

### Page 51

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for one side of the airplane.
More DataQtyIdentificationNameTaskStep
-1111T4020U13FITTING, UNDER-
WING LONGERON, LH
Locate1
-1-FITTING, INTERNAL
BATHTUB
Locate
(a) Shim A.1BACS40R016B018FSHIM, LAMINATEDLocate
(a) Shim B.1BACS40R020C032FSHIM, LAMINATEDLocate
(a) Shim C.1BACS40R014C022FSHIM, LAMINATEDLocate
(a)(q) Shim D.2BACS40R025C063FSHIM, LAMINATEDLocate
(b)16-RADIUS FILLERLocate2
(c)(d) Drill and ream
to final hole size.
Refer to the fastener
code table.
3-HOLEDrill3
FIGURE 21: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 3 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
345 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 52

More DataQtyIdentificationNameTaskStep
(c)(d)(e) Drill and
ream to final hole
size. Refer to the
fastener code table.
42-HOLEDrill4
(f)16-RADIUS FILLERRemove / Keep5
Shim A.1BACS40R016B018FSHIM, LAMINATEDRemove / Keep
Shim B.1BACS40R020C032FSHIM, LAMINATEDRemove / Keep
Shim C.1BACS40R014C022FSHIM, LAMINATEDRemove / Keep
(q) Shim D.2BACS40R025C063FSHIM, LAMINATEDRemove / Keep
-1-FITTING, INTERNAL
BATHTUB
Remove / Keep
-1111T4020U13FITTING, UNDER-
WING LONGERON, LH
Remove / Keep
Clean and deburr all
structure.
--STRUCTUREClean/Deburr
(g)1111T4020U13FITTING, UNDER-
WING LONGERON, LH
Install (New)6
(h)12-RADIUS FILLERInstall (Kept)7
(i) Refer to the fas-
tener code table.
34-FASTENERInstall (New)8
(j) Shim A.1BACS40R016B018FSHIM, LAMINATEDInstall (Kept)9
(j) Shim B.1BACS40R020C032FSHIM, LAMINATEDInstall (Kept)
(j) Shim C.1BACS40R014C022FSHIM, LAMINATEDInstall (Kept)
(j)1-FITTING, INTERNAL
BATHTUB
Install (Kept)
(k) Radius filler R.
Refer to the fastener
code table for stack-
up.
1140T0120-48SHIMInstall (New)
-1-TEMPORARY TEN-
SION BOLT
Install (New)
(l)4-RADIUS FILLERInstall (Kept)10
(m) Refer to the fas-
tener code table.
8-FASTENERInstall (New)11
FIGURE 21: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 4 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
346 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 53

More DataQtyIdentificationNameTaskStep
-1-TEMPORARY TEN-
SION BOLT
Remove12
Ream and deburr
the tension bolt hole
to final hole size.
Refer to the fastener
code table.
1-HOLEReam
(m) Refer to the fas-
tener code table.
1-FASTENERInstall (New)
(n)(q) Shim D.2BACS40R025C063FSHIM, LAMINATEDInstall (Kept)13
(m) Refer to the fas-
tener code table.
3-FASTENERInstall (New)14
(o)5 OzBMS 5-45SEALANTApply15
(p)5 OzBMS 5-95SEALANTApply16
(a) Delaminate and taper shim as required to get a 0.005 inch maximum gap.
(b) If a radius filler was removed from locations "A" through "P". Locate in the recorded orientation from re-
moval.
(c) Keep a minimum of 1.7D edge margin at all fastener locations on the underwing longeron fitting.
(d) For existing fastener that is nominal, first, or second oversized, install the same type and size fastener if
open hole HFEC confirms crack-free condition.
(e) Oversizing to second oversize fastener requires high interference cold-working. Cold work the hole in
accordance with 767-200 SRM 51-40-09 or 767-200SF SRM 51-40-09 or 767-300 SRM 51-40-09 or 767-
300BCF SRM 51-40-09 or 767-300F SRM 51-40-09.
(f) If a radius filler was removed from locations "A" through "P". Record the orientation of the radius filler at
each location for re-installation.
(g) Apply BMS 5-95 faying surface seal to the mating surface of the lower panel and the underwing longeron
fitting. Refer to SOPM 20-50-19 as an accepted procedure.
(h) If a radius filler was removed from locations "C" through "L", "O", and "P". Locate in the recorded orientation
from removal.
(i) Install the fasteners wet with BMS 5-45 to partially install the underwing longeron fitting. Refer to SOPM
20-50-19, and 767-200 SRM 51-40-02 or 767-200SF SRM 51-40-02 or 767-300 SRM 51-40-02 or 767-
300BCF SRM 51-40-02 or 767-300F SRM 51-40-02 as accepted procedures.
Do not install fasteners common to the internal bathtub fitting or the three forward fasteners that are
common to the underwing longeron fitting.
(j) Apply BMS 5-45 faying surface seal. Refer to SOPM 20-50-19 as an accepted procedure.
(k) As an option use kept shim for internal bathtub fitting, if installed.
(l) If a radius filler was removed from locations "A", "B", "M", and "N". Install in the recorded orientation.
FIGURE 21: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 5 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
347 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 54

More DataQtyIdentificationNameTaskStep
(m) Install fasteners wet with BMS 5-45. Refer to SOPM 20-50-19 as an accepted procedure.
(n) Apply BMS 5-95 faying surface seal to each shim. Refer to SOPM 20-50-19 as an accepted procedure.
(o) Apply cap seal to wing tank fasteners internally with BMS 5-45. Refer to 767 AMM 28-11-00 as an accepted
procedure.
(p) Apply BMS 5-95 to fillet seal around the perimeter of the underwing longeron fitting. Refer to SOPM 20-
50-19 as an accepted procedure.
(q) One or both Shim D may not have been previously installed. Install the necessary number of shim(s)
based on the findings during fitting removal. If shim(s) must be added at a location, use the appropriate
number of shim(s) as necessary.
The codes shown below agree with the letter shown in the upper left corner of the fastener symbols in the figure.
A number in the lower right corner gives the grip length of the fastener. The QTY numbers shown below are the
number of fasteners necessary for this figure.
More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.2621-0.264128BACB30NX8K( )XBOLT, PROTRUDING
HD
A
--28BACC30BH8COLLAR
Second oversize fastener.0.2777-0.279728BACB30NX8K( )YBOLT, PROTRUDING
HD
--28BACC30AC8COLLAR
First oversize fastener.0.3246-0.326611BACB30NX10K( )XBOLT, PROTRUDING
HD
B
--11BACC30BH10COLLAR
Second oversize fastener.0.3402-0.342211BACB30NX10K( )YBOLT, PROTRUDING
HD
--11BACC30AC10COLLAR
FIGURE 21: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 6 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
348 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 55

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.3871-0.38911BACB30NX12K( )XBOLT, PROTRUDING
HD
C
--1BACC30BH12COLLAR
Second oversize fastener.0.4027-0.40471BACB30NX12K( )YBOLT, PROTRUDING
HD
--1BACC30AC12COLLAR
First oversize fastener.0.4496-0.45161BACB30NX14K( )XBOLTD
--1BACC30BH14COLLAR
Second oversize fastener.0.4652-0.46721BACB30NX14K( )YBOLT
--1BACC30AC14COLLAR
First oversize fastener (if
5/16 inch hi-lok was in-
stalled.)
0.3246-0.32661BACB30NX10K( )XBOLT, PROTRUDING
HD
E
--1BACC30BH10COLLAR
Second oversize fastener.0.3402-0.34221BACB30NX10K( )YBOLT, PROTRUDING
HD
--1BACC30AC10COLLAR
First oversize fastener (if
5/16 inch bolt and nut was
installed.)
0.3276-0.32861BACB30US5K( )XBOLT, 12 PT HEAD
Under the bolt head.-1BACW10BP51CDWASHER, PLAIN
Under the nut.-1BACW10BP51DPWASHER, PLAIN
Torque nut to 243 to 258
inch lbs.
-1BACN10HR5CDNUT
First oversize fastener.0.6401-0.64113BACB30MR10A26XBOLTF
Under the bolt head.-3BACW10BP101CDWASHER, PLAIN
Under the nut.-3BACW10BP101DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
Second oversize fastener.0.6557-0.65673BACB30MR10A26YBOLT
Under the bolt head.-3BACW10BP102CDWASHER, PLAIN
Under the nut.-3BACW10BP102DPWASHER, PLAIN
Torque nut to 1843 to
1957 inch lbs.
-3BACN11Z10CDNUT
FIGURE 21: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 7 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
349 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 56

More DataHole DiaQtyIdentificationNameCode
First oversize fastener.0.5776-0.57861BACB30US9K( )XBOLT, 12 PT HEADG
Under the bolt head.-1BACW10BP91ACWASHER, PLAIN AND
COUNTERSUNK
Self-aligning washer set.
Under the head.
-1BACW10CA91CVWASHER
Self-aligning washer set.
Under the head.
-1BACW10CA10CCWASHER
Radius filler "R" under nut,
adjacent to bathtub fitting.
--140T0120-48SHIM
Self-aligning washer set.
Under the nut.
-1BACW10CA91CVWASHER
Self-aligning washer set.
Under the nut.
-1BACW10CA10CCWASHER
Between nut and self-
aligning washer, for grip
length adjustment.
-1BACW10BP91DPWASHER, PLAIN
Torque nut to 1746 to
1854 inch lbs.
-1BACN10HR9CDNUT
FIGURE 21: LEFT SIDE UNDERWING LONGERON FITTING P/N 111T4020U13 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 8 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
350 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

### Page 57 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
This Figure applies only to: Group 4, 6-7.
STA
FUSELAGE  783.04
FRONT SPAR  SKIN  UPPER DRAG
SPLICE ANGLE
UNDERWING  LOWER DRAG
LONGERON  SPLICE ANGLE
FITTING
UNDERWING LONGERON FITTING
3054665
FIGURE 22: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U14 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 1 OF 8)
Original Issue: October 10, 2024
Export Controlled ECCN: 9E991  767-57A0148 RB
See page 1 for details  351 of 416

### Page 58 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
SEAL RETAINER  RADIUS  FILLER "R"
FRONT
B  BATHTUB FITTING  INTERNAL  SPAR  SHIM "A"  (59
UNDERWING 1EXE  SHIM "C" (
LONGERON FITTING
STA
776.21
+
SHIMS "B" (1
8 LOCATIONS  D1 128
RADIUS  UNDERWING LONGERON  FITTING  -WD  3 LOCATIONS
FILLER 'B'  A-A
RADIUS
FILLER 'A'
FWD  RADIUS  etio etto
34 LOCATIONS  RADIUS  2 5 10  FILLER "B"  z5 B58
FILLER "C"
5)
RADIUS
FILLER "D"  SHIM "D"
250  (2 LOCATIONS)
1 5 13
2 5 10 RADIUS  FILLER "A"
RADIUS
FILLER "E"
250
RADIUS  FILLER "H"  FILLER "G"  RADIUS  B-B  RADIUS  FILLER "F"  250  3054666
FIGURE 22: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U14 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 2 OF 8)
Original Issue: October 10, 2024
767-57A0148 RB
Export Controlled ECCN: 9E991
See page 1 for details  352 of 416

### Page 59 (OCR)

REQUIREMENTS BULLETIN 767-57A0148
ALERT  ALERT
RADIUS
RADIUS  FILLER "K"  RADIUS
FILLER "L"  2 5 7  250  FILLER "J"  RADIUS  FILLER "I"  (2) 5)
315
RADIUS  RADIUS
FILLER "P"  FILLER "O"
FWD  251
RAD US  (₴5  \10
FILLER "N'
B  RADIUS
C-C  FILLER "M"
The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for one side of the airplane.
Step  Task  Name  Identification  Qty  More Data
Locate  FITTING, UNDER-  111T4020U14  1
WING LONGERON,
RH
Locate  FITTING, INTERNAL  1
BATHTUB
Locate  SHIM, LAMINATED  BACS40R016B018F  1  (a) Shim A.
Locate  SHIM, LAMINATED  BACS40R020C032F  1  (a) Shim B.
Locate  SHIM, LAMINATED  BACS40R014C022F  1  (a) Shim C.
Locate  SHIM, LAMINATED  BACS40R025C063F  2  (a) (q) Shim D.
2  Locate  RADIUS FILLER  16  (b)
Drill  HOLE  3  (c)(d) Drill and ream
to final hole size.
Refer to the fastener
code table.
FIGURE 22: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U14 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 3 OF 8)
Original Issue: October 10, 2024
Export Controlled ECCN: 9E991  767-57A0148 RB
See page 1 for details  353 of 416

### Page 60

More DataQtyIdentificationNameTaskStep
(c)(d)(e) Drill and
ream to final hole
size. Refer to the
fastener code table.
42-HOLEDrill4
(f)16-RADIUS FILLERRemove / Keep5
Shim A.1BACS40R016B018FSHIM, LAMINATEDRemove / Keep
Shim B.1BACS40R020C032FSHIM, LAMINATEDRemove / Keep
Shim C.1BACS40R014C022FSHIM, LAMINATEDRemove / Keep
(q) Shim D.2BACS40R025C063FSHIM, LAMINATEDRemove / Keep
-1-FITTING, INTERNAL
BATHTUB
Remove / Keep
-1111T4020U14FITTING, UNDER-
WING LONGERON,
RH
Remove / Keep
Clean and deburr all
structure.
--STRUCTUREClean/Deburr
(g)1111T4020U14FITTING, UNDER-
WING LONGERON,
RH
Install (New)6
(h)12-RADIUS FILLERInstall (Kept)7
(i) Refer to the fas-
tener code table.
34-FASTENERInstall (New)8
(j) Shim A.1BACS40R016B018FSHIM, LAMINATEDInstall (Kept)9
(j) Shim B.1BACS40R020C032FSHIM, LAMINATEDInstall (Kept)
(j) Shim C.1BACS40R014C022FSHIM, LAMINATEDInstall (Kept)
(j)1-FITTING, INTERNAL
BATHTUB
Install (Kept)
(k) Radius filler R.
Refer to the fastener
code table for stack-
up.
1140T0120-48SHIMInstall (New)
-1-TEMPORARY TEN-
SION BOLT
Install (New)
(l)4-RADIUS FILLERInstall (Kept)10
(m) Refer to the fas-
tener code table.
8-FASTENERInstall (New)11
FIGURE 22: RIGHT SIDE UNDERWING LONGERON FITTING P/N 111T4020U14 - TENSION BOLT AND
INTERNAL BATHTUB FITTING - INSTALLATION
(SHEET 4 OF 8)
Export Controlled ECCN: 9E991
See page 1 for details
Original Issue: October 10, 2024
767-57A0148 RB
354 of 416
REQUIREMENTS BULLETIN 767-57A0148
ALERTALERT

The text continues at https://openairdocs.org/service-documents/boeing/767-57a0148-rb/file/584eb11b859b.md?from=61

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.