# Boeing Alert Requirements Bulletin DC10-53A184 RB: No revision named, from page 37

- Rights: © The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2020-0779; AD 2020-22-15 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Boeing Alert Requirements Bulletin DC10-53A184 RB](https://openairdocs.org/service-documents/boeing/dc10-53a184-rb.md)
- Title as filed: DC10-53A184-RB  00--
- Pages: 62
- PDF: https://openairdocs.org/files/sha256/2f/03/2f032f367b02d551303d01a4b75864c2b20ce9d2d7f7d223fc8b4980094d301b
- Page: https://openairdocs.org/service-documents/boeing/dc10-53a184-rb/file/2f032f367b02

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 37 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
→0
TYPICAL CRACK  FWD
LOOKING DOWN  FLOOR BEAM  (TYPICAL)  B-B
× = TOT
TYPICAL CRACK  FASTENER PATTERN MAY VARY  ETHF INSPECTION
NOTE:  2902601
FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAMS
(SHEET 3 OF 10)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  37 of 62

### Page 38 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
× - T76
TYPICAL CRACK
STA  X = 107  GSNI  C-C
TYPICAL  CRACK
FASTENER PATTERN MAY VARY  ETHF INSPECTION
×  =  NOTE:  2902627
FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAMS
(SHEET 4 OF 10)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  38 of 62

### Page 39 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
TYPICAL CRACK  FLOOR BEAM  LOOKING UP  FLOOR BEAM  (TYPICAL)  D-D
TYPICAL CRACK
FASTENER PATTERN MAY VARY  ETHF INSPECTION
NOTE:  2902637
FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAMS
(SHEET 5 OF 10)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  39 of 62

### Page 40 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
TYPICAL  CRACK
FLOOR SUPPORT  TYPICAL  CRACK  LOOKING AFT  FLOOR BEAM  TYPICAL  E-E
STA  X = 107
TYPICAL  CRACK
FLOOR BEAM  FASTENER PATTERN MAY VARY  ETHF INSPECTION
NOTE:  2902640
FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAMS
(SHEET 6 OF 10)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  40 of 62

### Page 41 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
FWD
- LOOR BEAM
STA Y=1275 SHOWN STA Y=1293 SIMILAF
F-F
ATTACHED ANGLE
2
(3
ETHF INSPECTION
-LOOR BEAM MODIFICATIO!
STA Y=1275 SHOWN STA Y= 1293 SIMILAF  F-F  2902673
FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAMS
(SHEET 7 OF 10)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  41 of 62

### Page 42

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)--Floor Beam: Around
Fastener Holes
Inspect1
(b)--Floor Beam: Web and
Flange Surfaces
Inspect2
(c)--Floor Beam: Flange
Edges
Inspect3
FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAMS
(SHEET 8 OF 10)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
42 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

### Page 43

More DataQtyIdentificationNameTaskStep
(a) Do an ETHF inspection of the overwing floor beam web and the upper and lower flanges at each fastener
location for any crack from STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 1305 in accordance
with NDTSPM Part 06-10-01.001, Procedure 1. Inspect the beam upper flange on both surfaces. Inspect
the beam web on either face, as applicable to avoid obstructions. Inspect the beam lower flange on the
upper or lower surface, as applicable to avoid obstructions.
1. Calibrate instrument on the N3 notch, in accordance with Figu re 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method K, in accordance with Figure 3, Sheet 2 of the NDTSPM procedure
to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM proce-
dure.
3. To inspect, use Scan Method 44, in accordance with Figure 4, Sheets 1 and 2, of the NDTSPM
procedure.
4. Scan around all fastener holes on the web and flange surfaces  of the four floor beams, as noted
above. Structure attached to the floor beams does not have to be detached from the floor beams.
– From STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 13 05.
(b) Do an ETHF inspection of the flat surfaces of the floor beam flanges and webs for any crack from STA X
= 90 to 116 at stations Y = 1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001,
Procedure 1.
1. Calibrate instrument on the N5 notch, in accordance with Figu re 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method F, in accordance with Figure 3, Sheet 1 of the NDTSPM procedure
to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM proce-
dure.
3. To inspect, use Scan Method 61, in accordance with Figure 6, Sheet 1 and 2, of the NDTSPM
procedure.
4. Scan all web and flange surfaces of the four floor beams. Str ucture attached to the floor beams
does not have to be detached from the floor beams.
– From STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 13 05.
– Scan between fastener rows, and between holes and edges. Where no fasteners exist, scan
incrementally, approximately 1/4 inch apart.
– Scan angles which compose the floor beam (not repair angles).
FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAMS
(SHEET 9 OF 10)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
43 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

### Page 44

More DataQtyIdentificationNameTaskStep
(c) Do an ETHF inspection of the floor beam flange edges for any  crack from STA X = 90 to 116 at stations
Y = 1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.
1. Calibrate instrument using the N5 notch, in accordance with i n Figure 2 of the NDTSPM procedure.
2. Utilize Scan Method J, in accordance with Figure 3, Sheet 1 o f the NDTSPM procedure to produce
an impedance plane display similar to that shown in Figure 1 of the NDTSPM procedure.
3. To inspect, use Scan Method 71, in accordance with Figure 7, Sheets 1 and 2, of the NDTSPM
procedure.
4. Scan along all edges of the four floor beams (and attached an gle, if present). Structure attached
to the floor beams does not have to be detached from the floor beams.
– From STA X = 90 to 116 at stations Y = 1256, 1275, 1293 and 13 05.
FIGURE 4: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAMS
(SHEET 10 OF 10)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
44 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

### Page 45 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
This Figure applies only to: Group 1.
STA
Y = 1305
STA
Y = 1256
_ STA  _ STA  STA  VIS
Y = 1231  Y = 1256  Y = 1275  Y = 1293  Y = 1305  Y = 1321
STA 81
A
2885058
FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 1 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  Copyright © Unpublished  DC10-53A184 RB
Work - See page 1 for details.  45 of 62

### Page 46 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
STA
X = 107
X = 81.0
- B
INBD
3 INCHES
TYPICAL CRACK  TYPICAL  CRACK
ETHF INSPECTION  - B
LOOKING FORWARD
FLOOR BEAM SUPPORT
Y = 1305 SHOWN
Y = 1256, Y = 1275, AND Y = 1293 SIMILAR  2885092
A-A
FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 2 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  46 of 62

### Page 47 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
— FILLER
3 INCHES
- TYPICAL CRACK
TYPICAL
CRACK
ETHF INSPECTION
VIEW LOOKING INBOARD AT X = 81
Y = 1305 SHOWN,
Y = 1256, Y = 1275 AND Y = 1293 SIMILAR  B-B  2885156
FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 3 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  47 of 62

### Page 48

FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 4 OF 6)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
48 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

### Page 49 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
• FILLER
• FILLET
•TYPICAL CRACK
3 INCHES
- TYPICAL CRACK
-WD
Y = 1305 SHOWN,
Y = 1256, Y = 1275 AND Y = 1293 SIMILAR  ETHF INSPECTION
D-D  2902158
FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
_ FLOOR BEAM SUPPORTS
(SHEET 5 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  Copyright © Unpublished  DC10-53A184 RB
Work - See page 1 for details.  49 of 62

### Page 50

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)--Floor Beam Support:
Flange Surface
Inspect1
(b)--Floor Beam Support:
Flange Edges
Inspect2
(a) Do an ETHF inspection of the floor beam support flange flat surfaces for any crack for STA X=81 at STA
Y=1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.
1. Calibrate the instrument on the N5 notch, in accordance with Figure 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method F, in accordance with Figure 3, Sheet 1 of the NDTSPM procedure
to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM proce-
dure.
3. To inspect, use Scan Method 61, in accordance with Figure 6, Sheet 2 of the NDTSPM.
4. Scan both faces of each of the four flanges of the floor beam  supports.
– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from  the bottom of the floor
beam down a minimum of 3 inches.
– Thoroughly scan the fillet radius at the flange thickness chan ge.
(b) Do an ETHF inspection of the edges of the four flanges of the supports for any crack in accordance with
NDTSPM Part 06-10-01.001.
1. Calibrate instrument using the N9 notch, in accordance with F igure 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method H, in accordance with Figure 3, Sheet 2 of the NDTSPM procedure
to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM proce-
dure.
3. To inspect, scan along the edge of each of the four flanges o f the floor beam supports, to a
minimum of 3 inches below the floor beam, using Scan Method 71 in accordance with Figure 7,
Sheet 1 and 2 of the NDTSPM.
– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from  the bottom of the floor
beam down a minimum of 3 inches.
FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 6 OF 6)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
50 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

### Page 51 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
This Figure applies only to: Group 1.
STA
Y = 1305
10  STA
Y = 1256
_ STA  STA  STA  STA  STA  STA
Y = 1231  Y = 1256  Y = 1275  Y = 1293 Y = 1305  Y = 1321
STA 81
2902693
FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 1 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  51 of 62

### Page 52 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
STA
X = 107
X = 81.0
3 INCHES
TYPICAL  TYPICAL
CRACK  CRACK
ETHF INSPECTION
LOOKING FORWARD
FLOOR BEAM SUPPORT
Y = 1305 SHOWN
Y = 1256, Y = 1275, AND Y = 1293 SIMILAR  2902695
A-A
FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 2 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  52 of 62

### Page 53 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
FILLER-
3 INCHES
TYPICAL
CRACK
TYPICAL CRACK
ETHF INSPECTION
VIEW LOOKING INBOARD AT X = 81
Y = 1305 SHOWN,
Y = 1256, Y = 1275 AND Y = 1293 SIMILAR  B-B  2902696
FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 3 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  53 of 62

### Page 54

FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 4 OF 6)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
54 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

### Page 55 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
FILLER
TYPICAL CRACK
FILLET•
3 INCHES
TYPICAL CRACK
FWD
Y = 1305 SHOWN
ETHF INSPECTION  Y = 1256, Y = 1275 AND Y = 1293 SIMILAR
D-D  2902707
FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 5 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  55 of 62

### Page 56

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)--Floor Beam Support:
Flange Surface
Inspect1
(b)--Floor Beam Support:
Flange Edges
Inspect2
(a) Do an ETHF inspection of the floor beam support flange flat surfaces for any crack for STA X=81 at STA
Y=1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.
1. Calibrate instrument the N5 notch, in accordance with Figure 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method F, in accordance with Figure 3, Sheet 1 of the NDTSPM procedure
to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM proce-
dure.
3. To inspect, use scan Method 61, in accordance with Figure 6, Sheet 2 of the NDTSPM.
4. Scan both faces of each of the four flanges of the floor beam  supports.
– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from  the bottom of the floor
beam down a minimum of 3 inches.
– Thoroughly scan the fillet radius at the flange thickness chan ge.
(b) Do an ETHF inspection of the edges of the four flanges of th e supports for any crack for STA X=81 for
STA Y=1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.
1. Calibrate instrument using the N9 notch, in accordance with F igure 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method H, in accordance with Figure 3, Sheet 2 of the NDTSPM procedure
to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM proce-
dure.
3. To inspect, scan along the edge of each of the four flanges o f the floor beam supports, to a
minimum of 3 inches below the floor beam, using Scan Method 71 in accordance with Figure 7,
Sheet 1 and 2 of the NDTSPM.
– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from  the bottom of the floor
beam down a minimum of 3 inches.
FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 6 OF 6)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
56 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

### Page 57 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
This Figure applies only to: Group 2.
STA
Y = 1305
STA
Y = 1256
_ STA  STA  STA  STA  STA  STA
Y = 1231  Y = 1256  Y = 1275  Y = 1293 Y = 1305  Y = 1321
STA 81
2885151
FIGURE 7: LEFT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS
(SHEET 1 OF 3)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  57 of 62

### Page 58 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
STA  STA
X = 81  X = 107
STA
Y = 1305 SHOWN
Y = 1256
Y = 1275
Y = 1293
SIMILAR
B
LOOKING FORWARD
FLOOR BEAM SUPPORT
Y = 1305 SHOWN
Y = 1256, Y = 1275 AND Y = 1293 SIMILAR
A-A
TYPICAL
B-B
DETAILED INSPECTION  2885392
FIGURE 7: LEFT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS
(SHEET 2 OF 3)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Work - See page 1 for details.  Copyright © Unpublished  58 of 62

### Page 59

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)--Floor Beam Support:
Rods and Rod Ends
Inspect1
(a) Do a Detailed Inspection of the floor beam support rods, rod ends and attached pieces, for any crack for
STA X=81 at STA Y=1256, 1275, 1293 and 1305.
FIGURE 7: LEFT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
59 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

### Page 60 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
This Figure applies only to: Group 2.
STA
Y = 1305
STA
Y = 1256
STA  STA  STA  STA  STA  STA
Y = 1231  1256  Y = 1275  Y = 1293 Y = 1305  Y = 1321
STA 81
2902694
FIGURE 8: RIGHT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS
(SHEET 1 OF 3)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Work - See page 1 for details.  Copyright © Unpublished  60 of 62

### Page 61 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
STA  STA
X = 107  X = 81
Y = 1256
9281 = 1
SIMILAR
B-
LOOKING FORWARD
FLOOR BEAM SUPPORT
Y = 1305 SHOWN
Y = 1256, Y = 1275 AND Y = 1293 SIMILAR
A-A
TYPICAL
B-B
DETAILED INSPECTION  2902709
FIGURE 8: RIGHT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS
(SHEET 2 OF 3)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  61 of 62

### Page 62

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)--Floor Beam Support:
Rods and Rod Ends
Inspect1
(a) Do a Detailed Inspection of the floor beam support rods, rod ends and attached pieces, for any crack for
STA X=81 at STA Y=1256, 1275, 1293 and 1305.
FIGURE 8: RIGHT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
62 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.
