# Boeing Alert Requirements Bulletin DC10-53A184 RB: No revision named, from page 49

- Rights: © The Boeing Company. Filed by the FAA in regulations.gov docket FAA-2020-0779; AD 2020-22-15 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Boeing Alert Requirements Bulletin DC10-53A184 RB](https://openairdocs.org/service-documents/boeing/dc10-53a184-rb.md)
- Title as filed: DC10-53A184-RB  00--
- Pages: 62
- PDF: https://openairdocs.org/files/sha256/2f/03/2f032f367b02d551303d01a4b75864c2b20ce9d2d7f7d223fc8b4980094d301b
- Page: https://openairdocs.org/service-documents/boeing/dc10-53a184-rb/file/2f032f367b02

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 49 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
• FILLER
• FILLET
•TYPICAL CRACK
3 INCHES
- TYPICAL CRACK
-WD
Y = 1305 SHOWN,
Y = 1256, Y = 1275 AND Y = 1293 SIMILAR  ETHF INSPECTION
D-D  2902158
FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
_ FLOOR BEAM SUPPORTS
(SHEET 5 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  Copyright © Unpublished  DC10-53A184 RB
Work - See page 1 for details.  49 of 62

### Page 50

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)--Floor Beam Support:
Flange Surface
Inspect1
(b)--Floor Beam Support:
Flange Edges
Inspect2
(a) Do an ETHF inspection of the floor beam support flange flat surfaces for any crack for STA X=81 at STA
Y=1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.
1. Calibrate the instrument on the N5 notch, in accordance with Figure 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method F, in accordance with Figure 3, Sheet 1 of the NDTSPM procedure
to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM proce-
dure.
3. To inspect, use Scan Method 61, in accordance with Figure 6, Sheet 2 of the NDTSPM.
4. Scan both faces of each of the four flanges of the floor beam  supports.
– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from  the bottom of the floor
beam down a minimum of 3 inches.
– Thoroughly scan the fillet radius at the flange thickness chan ge.
(b) Do an ETHF inspection of the edges of the four flanges of the supports for any crack in accordance with
NDTSPM Part 06-10-01.001.
1. Calibrate instrument using the N9 notch, in accordance with F igure 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method H, in accordance with Figure 3, Sheet 2 of the NDTSPM procedure
to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM proce-
dure.
3. To inspect, scan along the edge of each of the four flanges o f the floor beam supports, to a
minimum of 3 inches below the floor beam, using Scan Method 71 in accordance with Figure 7,
Sheet 1 and 2 of the NDTSPM.
– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from  the bottom of the floor
beam down a minimum of 3 inches.
FIGURE 5: LEFT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 6 OF 6)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
50 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

### Page 51 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
This Figure applies only to: Group 1.
STA
Y = 1305
10  STA
Y = 1256
_ STA  STA  STA  STA  STA  STA
Y = 1231  Y = 1256  Y = 1275  Y = 1293 Y = 1305  Y = 1321
STA 81
2902693
FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 1 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  51 of 62

### Page 52 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
STA
X = 107
X = 81.0
3 INCHES
TYPICAL  TYPICAL
CRACK  CRACK
ETHF INSPECTION
LOOKING FORWARD
FLOOR BEAM SUPPORT
Y = 1305 SHOWN
Y = 1256, Y = 1275, AND Y = 1293 SIMILAR  2902695
A-A
FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 2 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  52 of 62

### Page 53 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
FILLER-
3 INCHES
TYPICAL
CRACK
TYPICAL CRACK
ETHF INSPECTION
VIEW LOOKING INBOARD AT X = 81
Y = 1305 SHOWN,
Y = 1256, Y = 1275 AND Y = 1293 SIMILAR  B-B  2902696
FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 3 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  53 of 62

### Page 54

FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 4 OF 6)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
54 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

### Page 55 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
FILLER
TYPICAL CRACK
FILLET•
3 INCHES
TYPICAL CRACK
FWD
Y = 1305 SHOWN
ETHF INSPECTION  Y = 1256, Y = 1275 AND Y = 1293 SIMILAR
D-D  2902707
FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 5 OF 6)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  55 of 62

### Page 56

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)--Floor Beam Support:
Flange Surface
Inspect1
(b)--Floor Beam Support:
Flange Edges
Inspect2
(a) Do an ETHF inspection of the floor beam support flange flat surfaces for any crack for STA X=81 at STA
Y=1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.001, Procedure 1.
1. Calibrate instrument the N5 notch, in accordance with Figure 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method F, in accordance with Figure 3, Sheet 1 of the NDTSPM procedure
to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM proce-
dure.
3. To inspect, use scan Method 61, in accordance with Figure 6, Sheet 2 of the NDTSPM.
4. Scan both faces of each of the four flanges of the floor beam  supports.
– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from  the bottom of the floor
beam down a minimum of 3 inches.
– Thoroughly scan the fillet radius at the flange thickness chan ge.
(b) Do an ETHF inspection of the edges of the four flanges of th e supports for any crack for STA X=81 for
STA Y=1256, 1275, 1293 and 1305 in accordance with NDTSPM Part 06-10-01.
1. Calibrate instrument using the N9 notch, in accordance with F igure 2 of the NDTSPM procedure.
2. Utilize calibration Scan Method H, in accordance with Figure 3, Sheet 2 of the NDTSPM procedure
to produce an impedance plane display similar to that shown in Figure 1 of the NDTSPM proce-
dure.
3. To inspect, scan along the edge of each of the four flanges o f the floor beam supports, to a
minimum of 3 inches below the floor beam, using Scan Method 71 in accordance with Figure 7,
Sheet 1 and 2 of the NDTSPM.
– For STA X = 81 at stations Y = 1256, 1275, 1293 and 1305, from  the bottom of the floor
beam down a minimum of 3 inches.
FIGURE 6: RIGHT SIDE - EDDY CURRENT HIGH FREQUENCY (ETHF) INSPECTION OF THE OVERWING
FLOOR BEAM SUPPORTS
(SHEET 6 OF 6)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
56 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

### Page 57 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
This Figure applies only to: Group 2.
STA
Y = 1305
STA
Y = 1256
_ STA  STA  STA  STA  STA  STA
Y = 1231  Y = 1256  Y = 1275  Y = 1293 Y = 1305  Y = 1321
STA 81
2885151
FIGURE 7: LEFT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS
(SHEET 1 OF 3)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  57 of 62

### Page 58 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
STA  STA
X = 81  X = 107
STA
Y = 1305 SHOWN
Y = 1256
Y = 1275
Y = 1293
SIMILAR
B
LOOKING FORWARD
FLOOR BEAM SUPPORT
Y = 1305 SHOWN
Y = 1256, Y = 1275 AND Y = 1293 SIMILAR
A-A
TYPICAL
B-B
DETAILED INSPECTION  2885392
FIGURE 7: LEFT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS
(SHEET 2 OF 3)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Work - See page 1 for details.  Copyright © Unpublished  58 of 62

### Page 59

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)--Floor Beam Support:
Rods and Rod Ends
Inspect1
(a) Do a Detailed Inspection of the floor beam support rods, rod ends and attached pieces, for any crack for
STA X=81 at STA Y=1256, 1275, 1293 and 1305.
FIGURE 7: LEFT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
59 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

### Page 60 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
This Figure applies only to: Group 2.
STA
Y = 1305
STA
Y = 1256
STA  STA  STA  STA  STA  STA
Y = 1231  1256  Y = 1275  Y = 1293 Y = 1305  Y = 1321
STA 81
2902694
FIGURE 8: RIGHT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS
(SHEET 1 OF 3)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Work - See page 1 for details.  Copyright © Unpublished  60 of 62

### Page 61 (OCR)

REQUIREMENTS BULLETIN DC10-53A184
ALERT  ALERT
STA  STA
X = 107  X = 81
Y = 1256
9281 = 1
SIMILAR
B-
LOOKING FORWARD
FLOOR BEAM SUPPORT
Y = 1305 SHOWN
Y = 1256, Y = 1275 AND Y = 1293 SIMILAR
A-A
TYPICAL
B-B
DETAILED INSPECTION  2902709
FIGURE 8: RIGHT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS
(SHEET 2 OF 3)
Original Issue: February 06, 2020
Export Controlled ECCN: 9E991  DC10-53A184 RB
Copyright © Unpublished
Work - See page 1 for details.  61 of 62

### Page 62

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for this figure.
More DataQtyIdentificationNameTaskStep
(a)--Floor Beam Support:
Rods and Rod Ends
Inspect1
(a) Do a Detailed Inspection of the floor beam support rods, rod ends and attached pieces, for any crack for
STA X=81 at STA Y=1256, 1275, 1293 and 1305.
FIGURE 8: RIGHT SIDE - DETAILED INSPECTION OF OVERWING FLOOR BEAM SUPPORTS
(SHEET 3 OF 3)
Export Controlled ECCN: 9E991
Copyright © Unpublished
Work - See page 1 for details.
Original Issue: February 06, 2020
DC10-53A184 RB
62 of 62
REQUIREMENTS BULLETIN DC10-53A184
ALERTALERT

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.
