### Page 1

Commercial 
Airplanes
767
Service Bulletin
Number: 767-28-0118
Original Issue: July 15, 2014
ATA System: 2821 2841
SUBJECT: FUEL - Fuel Quantity Indicating System (FQIS) - Built-In Test Equipment (BITE)
Procedure Test and Fuel Overfill Shutoff Surge Tank Sensor Circuit Test
Export of this technology is controlled under the United States Export Administration Regulations (EAR) (15
CFR 300-774). An export license may be required before it is used for development, production or use by foreign
persons from specific countries. The controller of this data has the individual responsibility to abide by all export
laws.
9E991ECCN:
BOEING PROPRIETARY, CONFIDENTIAL AND/OR TRADE SECRET
Copyright © 2014 Boeing.
Unpublished Work. All Rights Reserved.
Treatment of this document and its content is governed by contract with Boeing. Rights to use this document
are licensed on a per aircraft basis and such rights may not be transferable. For more information, contact The
Boeing Company.
Boeing, the Boeing signature, the Boeing symbol, 707, 717, 727, 737, 747, 757, 767, 777, 787, Dreamliner,
BBJ, DC-8, DC-9, DC-10, KC-10, KC-46, KDC-10, MD-10, MD-11, MD-80, MD-88, MD-90, P-8, Poseidon and
Boeing liveries are all trademarks owned by The Boeing Company; and no trademark license is granted in
connection with this document unless provided in writing by Boeing.
Original Issue: July 15, 2014
767-28-0118
1 of 30
3.0

### Page 2

Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
2 of 30
BOEING SERVICE BULLETIN 767-28-0118
BLANK PAGE

### Page 3

Table of Contents
Summary ...................................................... 5
1. PLANNING INFORMATION ........................................ 9
A. Effectivity ................................................ 9
1. Airplanes ............................................. 9
2. Spares Affected ........................................ 1 0
B. Concurrent Requirements ...................................... 1 0
C. Reason ................................................ 1 0
D. Description .............................................. 1 1
E. Compliance .............................................. 1 1
F. Approval ............................................... 1 4
G. Manpower .............................................. 1 4
H. Weight and Balance Changes .................................... 1 5
I. Electrical Load Data ......................................... 1 5
J. References .............................................. 1 5
1. Existing Data: ......................................... 1 5
2. Data Supplied with this Service Bulletin: ........................... 1 6
3. Installation Drawings Used in the Preparation of this Service Bulletin: ........... 1 6
K. Publications Affected ........................................ 1 6
L. Interchangeability and Intermixability of Parts ........................... 1 6
M. Software Accomplishment Summary ................................ 1 6
2. MATERIAL INFORMATION ........................................ 1 7
A. Material - Price and Availability ................................... 1 7
B. Industry Support Information .................................... 1 7
C. Parts Necessary for Each Airplane ................................. 1 7
1. Kits/Parts ............................................ 1 7
2. Parts and Materials Supplied by the Operator ........................ 1 7
3. Parts Modified and Reidentified ................................ 1 7
4. Parts Removed and Not Replaced .............................. 1 7
D. Parts Necessary to Change Spares ................................. 1 7
E. Special Tooling - Price and Availability ............................... 1 7
F. Special Tooling Necessary to do this Service Bulletin ....................... 1 7
3. ACCOMPLISHMENT INSTRUCTIONS .................................. 1 9
A. GENERAL INFORMATION ..................................... 1 9
B. WORK INSTRUCTIONS ....................................... 2 0
FIGURE 1: MAIN EQUIPMENT CENTER - FUEL QUANTITY PROCESSOR UNIT - INSPECT .... 2 9
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
3 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 4

Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
4 of 30
BOEING SERVICE BULLETIN 767-28-0118
BLANK PAGE

### Page 5

Commercial 
Airplanes
767
Service Bulletin
SummaryNumber: 767-28-0118Original Issue: July 15, 2014
ATA System: 2821 2841
SUBJECT: FUEL - Fuel Quantity Indicating System (FQIS) - Built-In Test Equipment (BITE)
Procedure Test and Fuel Overfill Shutoff Surge Tank Sensor Circuit Test
CONCURRENT REQUIREMENTS
Refer to Paragraph 1.B., Concurrent Requirements.
BACKGROUND
This service bulletin is applicable to all previously delivered 767 freighter airplanes and Boeing Converted
Freighter Airplanes that are not equiped with a Nitrogen Generation System (NGS). This service bulletin gives
instructions to test the Fuel Quantity Indicating System (FQIS) for latent failures of system components by
performing the "Fuel Quantity BITE Procedure" test of the Fuel Quantity Processor Unit (FQPU) to identify
specific, non-dispatchable faults. If the BITE procedure detects FQIS in-tank failures, Operators must identify
the faults using the appropriate FIM Section for troubleshooting and must fix the faults prior to releasing the
airplane to normal service. This service bulletin also provides instructions to test the surge tank sensor circuits
for latent failures using existing FIM procedures. If this service bulletin is not done an undetected (latent) Center
Wing Tank FQIS in-tank short fault or latent surge tank sensor wiring fault under additional failure conditions
could result in a potential source of ignition in a fuel tank.
Based on the Fuel Tank Flammability Reduction Rule requirements the 767 airplanes should have the Nitrogen
Generating System (NGS) installed in order to reduce the Center Wing Tank flammability exposure. There is a
potential that certain latent failures inside the tank combined with a hot short failure outside the tank may introduce
an ignition source in the Center Wing Tank. The "Fuel Quantity BITE Procedure" displays faults and ensures
that the Center Wing Tank Fuel Quantity Indicating System does not have these faults that could affect the tank
safety. The Dry Capacitance test for the overfill shutoff surge tank sensor circuits ensures that the wiring for the
Center Wing Tank does not have faults.
Boeing Service Related Problem (SRP) 767-SRP-28-149 is related to this service bulletin.
This table is provided to operators for planning purposes only. Refer to the applicable sections for more
information.
ReferenceAffectedPlanning Data
Paragraph 1.A.2., Spares AffectedNoSpares Affected
Paragraph 1.E., Compliance and Paragraph
1.F., Approval
YesAD Related
Paragraph 1.H., Weight and Balance ChangesNoWeight and Balance Change
Paragraph 1.I., Electrical Load DataNoElectrical Load Changed
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
5 of 30

### Page 6

ReferenceAffectedPlanning Data
Paragraph 1.K., Publications AffectedNoPublications Affected
Paragraph 1.K., Publications AffectedNoAirplane Flight Operations Affected (Flight Crew
Operations Manual and/or FAA Approved Air-
plane Flight Manual)
Paragraph 2.C.1., Kits/PartsNoKits/Parts Required
Paragraph 2.C.2., Parts and Materials Supplied
by the Operator
NoOperator Supplied Parts/Material
Paragraph 2.F., Special Tooling Necessary to
do this Service Bulletin
NoSpecial Tooling Required
ACTION
Get access to Main Equipment Center (MEC) at the E2-4 electronics shelf, at the Fuel Quantity Processor Unit
(FQPU).
Do the "Fuel Quantity BITE Procedure" to test the FQPU for in-tank faults.
After the test is complete check the FQPU if faults are detected.
1. If the BITE procedure is passing (there are no faults).
a. No action is required.
2. If the BITE procedure detects faults:
a. Isolate the fault codes.
b. Repair or replace damaged FQIS system wires or components before further flight to correct the
faults detected.
c. Repeat the "Fuel Quantity BITE Procedure" to confirm that faults no longer exist.
Get access to the Electrical System Card File, P50, in the EE Bay.
Do the "Dry Capacitance Test" for the Left and Right Surge Tank Fuel Level Sensors.
Close access and put the airplane back to a serviceable condition.
EFFECTIVITY
767-300/-300F Airplane(s). Refer to Paragraph 1.A.1., Airplanes, for the list of affected airplane(s).
COMPLIANCE
The Federal Aviation Administration (FAA) will possibly release an Airworthiness Directive related to this service
bulletin. The Airworthiness Directive will make the compliance tasks and times given in this service bulletin
mandatory.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
6 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 7

Refer to Paragraph 1.E., Compliance.
INDUSTRY SUPPORT INFORMATION
Boeing warranty remedies are not available for the change given in this service bulletin.
MANPOWER
Refer to Paragraph 1.G., Manpower.
MATERIAL INFORMATION
None.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
7 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 8 (OCR)

BOEING SERVICE BULLETIN 767-28-0118
DO THE "FUEL QUANTITY BITE
A PROCEDURE" TO MAKE SURE
THERE ARE NO FQIS FAULTS
FUEL QUANTITY
PROCESSOR UNIT
(FQPU)
(E2-4)
P50 CARD FILE:
DO THE "DRY CAPACITANCE TEST"
FOR THE LEFT AND RIGHT SURGE  MAIN EQUIPMENT CENTER
TANK FUEL LEVEL SENSORS TO TEST
THE SURGE TANK SENSOR CIRCUITS
FOR LATENT FAILURES.
DISPLAY
DISPLAY
MENU
BUTTONS
MENU
BUTTONS
HONEYWELL
SIMMONDS/GOODRICH
FUEL QUANTITY PROCESSOR UNIT  2327497
Original Issue: July 15, 2014
PROPRIETARY - Copyright © Unpublished  Export Controlled ECCN: 9E991 - BOEING  767-28-0118
Work - See page 1 for details.  8 of 30

### Page 9

Commercial 
Airplanes
767
Service Bulletin
Number: 767-28-0118
Original Issue: July 15, 2014
ATA System: 2821 2841
SUBJECT: FUEL - Fuel Quantity Indicating System (FQIS) - Built-In Test Equipment (BITE)
Procedure Test and Fuel Overfill Shutoff Surge Tank Sensor Circuit Test
1.    PLANNING INFORMATION
A. Effectivity
1. Airplanes
Refer to Service Bulletin Index D624T001 Part 3 for Airplane Variable Number, Line Number, and
Serial Number data.
This service bulletin is applicable to 767-300/-300F, line numbers 269, 285,379, 432, 438, 463,
484, 556, 580, 590, 594, 598, 600, 616, 622, 624, 626, 628, 630, 632, 634, 636, 638, 640, 645,
660, 666, 670, 672, 674, 678, 682, 724, 726, 728, 730, 732, 756, 760, 764, 854, 858, 712, 778,
806, 846, 848, 860, 979, 983, 986, 988, 989, 991, 992, 885, 934, 936, 948, 937, 939, 947,956,
959 and 960 in two Group(s). The Variable Numbers and Group Information for the applicable
airplanes is given below.
DESCRIPTIONCONFIGURATIONGROUP
767 Freighters Airplanes and Boeing Converted Freighters Airplanes
(BCF) delivered with Goodrich FQIS that are not equipped with a
Center Wing Tank Nitrogen Generation System (NGS)
-1
767 Freighters Airplanes and Boeing Converted Freighters Airplanes
(BCF) delivered with Honeywell FQIS that are not equipped with a
Center Wing Tank Nitrogen Generation System (NGS)
-2
Airplane Models:
767-300, 767-300F
GroupVariable Number
2VN191 - VN194
1VN195 - VN197
2VN792
1VN921
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
9 of 30

### Page 10

GroupVariable Number
1VR201 - VR211
1VR251
1VR256 - VR260
1VR266 - VR272
1VT501
1VT511 - VT513
1VT521 - VT523
1VT531 - VT533
1VW701 - VW721
1VW851
2. Spares Affected
None.
B. Concurrent Requirements
None.
C. Reason
This service bulletin is applicable to all previously delivered 767 freighter airplanes and Boeing Converted
Freighter Airplanes that are not equiped with a Nitrogen Generation System (NGS). This service bulletin
gives instructions to test the Fuel Quantity Indicating System (FQIS) for latent failures of system
components by performing the "Fuel Quantity BITE Procedure" test of the Fuel Quantity Processor
Unit (FQPU) to identify specific, non-dispatchable faults. If the BITE procedure detects FQIS in-tank
failures, Operators must identify the faults using the appropriate FIM Section for troubleshooting and
must fix the faults prior to releasing the airplane to normal service. This service bulletin also provides
instructions to test the surge tank sensor circuits for latent failures using existing FIM procedures. If
this service bulletin is not done an undetected (latent) Center Wing Tank FQIS in-tank short fault or
latent surge tank sensor wiring fault under additional failure conditions could result in a potential source
of ignition in a fuel tank.
Based on the Fuel Tank Flammability Reduction Rule requirements the 767 airplanes should have the
Nitrogen Generating System (NGS) installed in order to reduce the Center Wing Tank flammability
exposure. There is a potential that certain latent failures inside the tank combined with a hot short
failure outside the tank may introduce an ignition source in the Center Wing Tank. The "Fuel Quantity
BITE Procedure" displays faults and ensures that the Center Wing Tank Fuel Quantity Indicating System
does not have these faults that could affect the tank safety. The Dry Capacitance test for the overfill
shutoff surge tank sensor circuits ensures that the wiring for the Center Wing Tank does not have faults.
Boeing Service Related Problem (SRP) 767-SRP-28-149 is related to this service bulletin.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
10 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 11

D. Description
Get access to Main Equipment Center (MEC) at the E2-4 electronics shelf, at the Fuel Quantity Processor
Unit (FQPU).
Do the "Fuel Quantity BITE Procedure" to test the FQPU for in-tank faults.
After the test is complete check the FQPU if faults are detected.
1. If the BITE procedure is passing (there are no faults).
a. No action is required.
2. If the BITE procedure detects faults:
a. Isolate the fault codes.
b. Repair or replace damaged FQIS system wires or components before further flight to correct
the faults detected.
c. Repeat the "Fuel Quantity BITE Procedure" to confirm that faults no longer exist.
Get access to the Electrical System Card File, P50, in the EE Bay.
Do the "Dry Capacitance Test" for the Left and Right Surge Tank Fuel Level Sensors.
Close access and put the airplane back to a serviceable condition.
The work in this service bulletin is done in the maintenance zone(s) given below.
Group 1:
Affected Maintenance Zones
ZoneModel
119, 521, 621767-300, 767-300F
Group 2:
Affected Maintenance Zones
ZoneModel
119, 521, 621767-300
E. Compliance
The Federal Aviation Administration (FAA) will possibly release an Airworthiness Directive related to
this service bulletin. The Airworthiness Directive will make the compliance tasks and times given in this
service bulletin mandatory.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
11 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 12

Table 1: INSPECTION TO DETERMINE FQPU
Repeat Interval
(Not to Exceed)
Compliance TimeActionCondition
750 flight hours. (a)Within 6 months
after the original is-
sue date of this
Service Bulletin.
Inspect for part number
on the FQPU to deter-
mine if the FQPU is SIM-
MONDS/GOODRICH or
HONEYWELL.
All Airplanes
-At the times in Ta-
ble 2.
Do the actions in Table 2.Airplanes with SIM-
MONDS/GOODRICH
FQPU.
-At the times in Ta-
ble 3.
Do the actions in Table 3.Airplanes with HONEY-
WELL FQPU.
(a) Accomplishment of 767-47-0001, installation of Nitrogen Gas System is closing action for
the repeat inspections.
Group 1:
Table 2: FUEL QUANTITY BITE PROCEDURE FOR AIRPLANES WITH SIMMONDS/GOODRICH
FUEL QUANTITY INDICATING SYSTEM (FQIS)
Repeat Interval
(Not to Exceed)
Compliance TimeActionCondition
750 flight hours. (a)Within 6 months
after the original is-
sue date of this
Service Bulletin.
Do PART 4: FUEL
QUANTITY BITE PROCE-
DURE - SIM-
MONDS/GOODRICH
FQPU to Test the FQPU
for in Tank Faults.
Group 1 Airplanes
--Close assembly.CONDITION 1: TEST
COMPLETE FQIS FAULT
NOT FOUND
Put the airplane back to
a serviceable condition.
-Before further
flight.
Identify the fault codes
recorded during the BITE
Procedure.
CONDITION 2: TEST
COMPLETE FQIS FAULT
FOUND
Repair or replace dam-
aged FQIS system wires
or components to correct
the faults.
Repeat the "Fuel Quantity
BITE Procedure" to con-
firm that FAULTS no
longer exist.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
12 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 13

Group 1:
Table 2: FUEL QUANTITY BITE PROCEDURE FOR AIRPLANES WITH SIMMONDS/GOODRICH
FUEL QUANTITY INDICATING SYSTEM (FQIS)
Repeat Interval
(Not to Exceed)
Compliance TimeActionCondition
750 flight hours. (a)Within 6 months
after the original is-
sue date of this
Service Bulletin.
Do the "Dry Capacitance
Test" for the Left and
Right Surge Tank Fuel
Level Sensor in accor-
dance with "PART 2" to
Test the Surge Tank
Sensor Circuits.
Group 1 Airplanes
-Before further
flight.
Do corrective actions.Capacitance value is not
between 6.50 to 8.05 pico-
farads.
(a) Accomplishment of 767-47-0001, installation of Nitrogen Gas System is closing action for
the repeat inspections.
Group 2:
Table 3: FUEL QUANTITY BITE PROCEDURE FOR AIRPLANES WITH HONEYWELL FUEL
QUANTITY INDICATING SYSTEM (FQIS)
Repeat Interval
(Not to Exceed)
Compliance TimeActionCondition
750 flight hours. (a)Within 6 months
after the original is-
sue date of this
Service Bulletin.
Do PART 5: FUEL
QUANTITY BITE PROCE-
DURE - HONEYWELL
FQPU to Test the FQPU
for in Tank Faults.
Group 2 Airplanes
--Close assembly.CONDITION 1: TEST
COMPLETE FQIS FAULT
NOT FOUND
Put the airplane back to
a serviceable condition.
-Before further
flight.
Identify the fault codes
recorded during the BITE
Procedure.
CONDITION 2: TEST
COMPLETE FQIS FAULT
FOUND
Repair or replace dam-
aged FQIS system wires
or components to correct
the faults.
Repeat the "Fuel Quantity
BITE Procedure" to con-
firm that FAULTS no
longer exist.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
13 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 14

Group 2:
Table 3: FUEL QUANTITY BITE PROCEDURE FOR AIRPLANES WITH HONEYWELL FUEL
QUANTITY INDICATING SYSTEM (FQIS)
Repeat Interval
(Not to Exceed)
Compliance TimeActionCondition
750 flight hours. (a)Within 6 months
after the original is-
sue date of this
Service Bulletin.
Do the "Dry Capacitance
Test" for the Left and
Right Surge Tank Fuel
Level Sensor in accor-
dance with "PART 3" to
Test the Surge Tank
Sensor Circuits.
Group 2 Airplanes
-Before further
flight.
Do corrective actions.Capacitance value is not
between 6.50 to 8.05 pico-
farads.
(a) Accomplishment of 767-47-0001, installation of Nitrogen Gas System is closing action for
the repeat inspections.
F. Approval
This service bulletin was examined by the Federal Aviation Administration (FAA). The changes specified
in this service bulletin comply with the applicable regulations and are FAA approved, as well as European
Aviation Safety Agency (EASA)/Joint Aviation Authorities (JAA) approved for all EASA/JAA approved
airplanes listed in the service bulletin effectivity. This service bulletin and its approval were based on
the airplane in its original Boeing delivery configuration or as modified by other approved Boeing
changes.
If an airplane has a non-Boeing modification or repair that affects a component or system also affected
by this service bulletin, the operator is responsible for obtaining appropriate regulatory agency approval
before incorporating this service bulletin.
G. Manpower
The table below shows an estimate of the task hours necessary to do this for each airplane. This
estimate is for direct labor only, done by an experienced crew. Adjust the estimate with operator task
hour data if necessary. The estimate does not include lost time. These are some examples of lost time:
 Time to adjust to the workplace
 Time to schedule the work
 Time to inspect the work
 Time to cure the materials
 Time to make the parts
 Time to find the tools.
Group 1:
Elapsed HoursTask HoursNumber of PersonsTask
0.750.751Open Access
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
14 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 15

Group 1:
Elapsed HoursTask HoursNumber of PersonsTask
0.250.251Fuel Quantity BITE
Procedure
4.0016.004Dry Capacitance
Test for the Left and
Right Surge Tank
Fuel Level Sensors
0.750.751Close Access
5.7517.75TOTAL FOR EACH AIRPLANE
(a) The time to make the change to get CONDITION 1 results in accordance with
Table 1 Simmonds/Goodrich FQIS faults is not included.
Group 2:
Elapsed HoursTask HoursNumber of PersonsTask
0.750.751Open Access
0.250.251Fuel Quantity BITE
Procedure
4.0016.004Dry Capacitance
Test for the Left and
Right Surge Tank
Fuel Level Sensors
0.750.751Close Access
5.7517.75TOTAL FOR EACH AIRPLANE
(a) The time to make the change to get CONDITION 1 results in accordance with
Table 1 Honeywell FQIS faults is not included.
H. Weight and Balance Changes
None.
I. Electrical Load Data
Not changed.
J. References
1. Existing Data:
a. Boeing Service Related Problem (SRP) 767-SRP-28-149
b. Service Bulletin Index D624T001
c. Standard Wiring Practices Manual (SWPM) 20-10-06, 20-10-11, 20-10-12, 20-10-13, 20-10-19
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
15 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 16

d. 767 Aircraft Maintenance Manual (AMM) 06-44-00, 24-22-00, 28-21-04, 28-41-00, CONFIG
1, 28-41-00, CONFIG 2, 28-41-00, 28-41-01, 28-41-02, 28-41-03, 28-41-09
e. 767 Fault Isolation Manual (FIM) 28-21 FAULT TREE 805, 28-21 FAULT TREE 806, 28-41-00
Config 4, 28-41 FAULT TREE 849 Config 4, 28-41 FAULT TREE 851 Config 4, 28-41 TASK
854, 28-41 TASK 855
f. 767 Wiring Diagram Manual (WDM) 28-21-12, 28-41-21, 28-41-22, 28-41-23
2. Data Supplied with this Service Bulletin:
None.
3. Installation Drawings Used in the Preparation of this Service Bulletin:
None.
K. Publications Affected
1. Publications:
None.
2. Damage Tolerance Based Structural Inspections:
Boeing has evaluated the repairs and/or changes in this service bulletin for effects on Fatigue
Critical Structure (FCS) and for changes to Damage Tolerance Inspections (DTI) required in the
Maintenance Program. This service bulletin does not affect FCS, therefore DTIs are not necessary.
L. Interchangeability and Intermixability of Parts
Accomplishment of this service bulletin does not affect interchangeability or intermixability of parts.
M. Software Accomplishment Summary
Not affected.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
16 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 17

2.    MATERIAL INFORMATION
A. Material - Price and Availability
None.
B. Industry Support Information
Boeing warranty remedies are not available for the configuration changes inspection, and/or repair
procedures given in this service bulletin.
C. Parts Necessary for Each Airplane
1. Kits/Parts
None.
2. Parts and Materials Supplied by the Operator
None.
3. Parts Modified and Reidentified
None.
4. Parts Removed and Not Replaced
None.
D. Parts Necessary to Change Spares
None.
E. Special Tooling - Price and Availability
None.
F. Special Tooling Necessary to do this Service Bulletin
None.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
17 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 18

Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
18 of 30
BOEING SERVICE BULLETIN 767-28-0118
BLANK PAGE

### Page 19

3.    ACCOMPLISHMENT INSTRUCTIONS
A. GENERAL INFORMATION
CAUTION: KEEP THE WORK AREA, WIRES AND ELECTRICAL BUNDLES CLEAN OF METAL
PARTICLES OR CONTAMINATION WHEN YOU USE TOOLS. UNWANTED MATERIAL,
METAL PARTICLES OR CONTAMINATION CAUGHT IN WIRE BUNDLES CAN CAUSE
DAMAGE TO THE BUNDLES. DAMAGED WIRE BUNDLES CAN CAUSE SPARKS OR
OTHER ELECTRICAL DAMAGE.
NOTE: 1. Manual titles are referred to by acronyms. Refer to Paragraph 1.J., References, for
definition of the acronyms.
2. Obey all of the warnings and cautions given in the specified manual sections.
3. The work instructions are divided into work packages. Task Hours and Elapsed Hours
for each package are given in Paragraph 1.G., Manpower. You can do each work
package independently.
4. Unless shown differently, these dimensions and tolerances are used:
– Linear dimensions are in inches
– Tolerance on linear dimensions, other than rivet and bolt edge margins, is plus
or minus 0.03 inch
– Tolerance on rivet and bolt edge margin is plus or minus 0.05 inch
– Angular tolerance is plus or minus 2 degrees
– Hole dimensions for standard solid rivets and fasteners are in Structural Repair
Manual (SRM) Chapter 51
– Torque Values:
— Values for structural fasteners are given in 767 Structural Repair Manual,
Chapter 51.
— Values for airframe maintenance tasks are included in Chapter 20 of 767
Airplane Maintenance Manual (AMM).
— Values for electrical maintenance tasks are included in Chapter 20 of
Standard Wiring Practices Manual (SWPM).
— Values for engine maintenance tasks are included in Chapter 70 of 767
Airplane Maintenance Manual (AMM).
— Non-standard torque values for maintenance tasks are included in the
applicable installation step.
5. Use the approved fastener, process and material substitutions in accordance with
SRM Chapter 51.
6. Refer to the SWPM 20-10-11 and SWPM 20-10-12 for the wire installation procedures,
and SWPM 20-10-19 for the wire separation requirements, as accepted procedures.
7. The necessary conditions for selection of clamp type and size are included in SWPM
20-10-12. If any wire bundle support clamp specified in this service bulletin does not
make a correct fit on the wire bundle, refer to SWPM 20-10-12 as an accepted
procedure to select a clamp that fits correctly.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
19 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 20

8. These work instructions refer to procedures included in other Boeing documents.
When the words "refer to" are used and the operator has an accepted alternative
procedure, the accepted alternative procedure can be used. When the words "in
accordance with" are included in the instruction, the procedure in the Boeing document
must be used.
9. If it is necessary to remove more parts for access, you can remove those parts. If
you can get access without removing identified parts, it is not necessary to remove
all of the identified parts. Jacking and shoring limitations must be observed.
10. Where the work instructions include installation of a kept part, a new or serviceable
part with the same part number can be installed as an alternative to the kept part.
11. This service bulletin includes functional test procedures for the systems changed by
this service bulletin. More functional tests can possibly be necessary in accordance
with standard maintenance practices because of interruption to other airplane systems.
12. If shading is used, shaded areas in Figures are to separate the non-critical and
non-authoritative information from the critical and authoritative information.
13. Use of colors in Figures is based on guidance from the ATA e-Business Program
(ATA) iSpec 2200.
14. When more than one OPTION is given for a CONDITION, do only one of the OPTION
numbers. When more than one ACTION is given for a CONDITION number or an
OPTION number, do all of the ACTION numbers for that CONDITION number or
OPTION number.
15. The compliance times for the actions in Paragraph 3.B., WORK INSTRUCTIONS
are in Paragraph 1.E., Compliance.
16. Some steps in the Work Instructions are identified as Required for Compliance (RC).
If this service bulletin is mandated by an Airworthiness Directive (AD), then the steps
identified as RC must be done to comply with the AD. Alternative procedures for
steps not identified with RC can be used if the RC steps can still be done as specified,
and the airplane can be put back in a serviceable condition. An Alternative Method
of Compliance (AMOC) is not necessary for deviations to steps that are not identified
as RC.
B. WORK INSTRUCTIONS
1. Do PART 1: GAIN ACCESS AND DETERMINE THE CONFIGURATION OF THE FUEL QUANTITY
PROCESSOR UNIT (FQPU).
2. Group 1:
Do PART 2: AIRPLANES WITH SIMMONDS/GOODRICH FUEL QUANTITY INDICATING SYSTEM
(FQIS) - FQIS BITE CHECK AND SURGE TANK SENSOR DRY CAPACITANCE TEST.
3. Group 2:
Do PART 3: AIRPLANES WITH HONEYWELL FUEL QUANTITY INDICATING SYSTEM (FQIS)
- FQIS BITE CHECK AND SURGE TANK SENSOR DRY CAPACITANCE TEST.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
20 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 21

PART 1: GAIN ACCESS AND DETERMINE THE CONFIGURATION OF THE FUEL QUANTITY
PROCESSOR UNIT (FQPU)
1. Close the fueling station doors 521QB and 621QB, if they are not already closed. Refer to 767
AMM 06-44-00 as an accepted procedure.
2. Supply electrical power to the airplane. Refer to 767 AMM 24-22-00 as an accepted procedure.
3. Close the Circuit Breakers if they are not already closed:
TitleCircuit BreakerLocationPanel
FUEL QTY #1C01048C34P11
FUEL QTY #2C01053M19P11
FUEL QTY REFUELC01040L02P34
FUELING QTYC01045E04P6
4. Open the Main Equipment Center access door 119AL to get access to the E2-4 electronics shelf.
Refer to 767 AMM 28-41-00 as an accepted procedure.
5. RC - At E2-4 electronics shelf, inspect for part number on Fault Quantity Processor Unit (FQPU)
in accordance with FIGURE 1 and determine if the FQPU is SIMMONDS/GOODRICH or
HONEYWELL and follow the applicable procedure.
APPLICABLE PROCEDUREFUEL QUANTITY PROCESSOR UNIT
GROUP 1SIMMONDS/GOODRICH
GROUP 2HONEYWELL
Group 1:
PART 2: AIRPLANES WITH SIMMONDS/GOODRICH FUEL QUANTITY INDICATING SYSTEM
(FQIS) - FQIS BITE CHECK AND SURGE TANK SENSOR DRY CAPACITANCE TEST
1. RC - Do PART 4: FUEL QUANTITY BITE PROCEDURE - SIMMONDS/GOODRICH FQPU.
a. CONDITION 1: TEST COMPLETE FQIS FAULT NOT FOUND
NOTE: There are no faults within the FQIS system.
(1) No further action is required.
(2) Continue with step 2.
b. CONDITION 2: TEST COMPLETE FQIS FAULT FOUND
NOTE: There are faults within the FQIS system.
(1) Identify the fault codes recorded during the "Fuel Quantity BITE Procedure". If any of the
faults listed in "Table 1 - GOODRICH FQIS Faults" are detected, they will have to be
corrected. Make a written record of all the FAULT messages detected.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
21 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 22

Table 1 - SIMMONDS/GOODRICH FQIS Faults
FIM Task (reference only)Fault Message
Figure 108 Sheet 2CT TU 01 OPEN LOZ OR HIZ WIRE
Figure 108 Sheet 2CT TU 02 OPEN LOZ OR HIZ WIRE
Figure 108 Sheet 2CT TU 03 OPEN LOZ OR HIZ WIRE
Figure 108 Sheet 2CT TU 04 OPEN LOZ OR HIZ WIRE
Figure 108 Sheet 2CT TU 05 OPEN LOZ OR HIZ WIRE
Figure 108 Sheet 2CT TU 06 OPEN LOZ OR HIZ WIRE
Figure 108 Sheet 2CT TU 07 OPEN LOZ OR HIZ WIRE
Figure 108 Sheet 2CT TU 08 OPEN LOZ OR HIZ WIRE
Figure 108 Sheet 2CT TU 09 OPEN LOZ OR HIZ WIRE
Figure 108 Sheet 6CT TU 01 SHORTED TO GROUND
Figure 108 Sheet 6CT TU 02 SHORTED TO GROUND
Figure 108 Sheet 6CT TU 03 SHORTED TO GROUND
Figure 108 Sheet 6CT TU 04 SHORTED TO GROUND
Figure 108 Sheet 6CT TU 05 SHORTED TO GROUND
Figure 108 Sheet 6CT TU 06 SHORTED TO GROUND
Figure 108 Sheet 6CT TU 07 SHORTED TO GROUND
Figure 108 Sheet 6CT TU 08 SHORTED TO GROUND
Figure 108 Sheet 6CT TU 09 SHORTED TO GROUND
Figure 108 Sheet 7CT COMP OPEN LOZ OR HIZ WIRE
Figure 108 Sheet 10CT TU COMP SHORTED TO GROUND
Figure 108 Sheet 13CT HIZ WIRE OPEN AT PROCESSOR
Figure 108 Sheet 15CT HIZ WIRE LOW RESISTANCE
Figure 108 Sheet 17CT HIZ SHIELD SHORT TO GND
Figure 108 Sheet 38CT TU ?? SHORTED TO GROUND
(2) Do corrective actions for each fault code detected that is listed in "Table 1 -
SIMMONDS/GOODRICH FQIS Faults". Refer to the Fault Code Index in the 767 FIM
28-41 FAULT TREE 849 Config 4 for applicable fault isolation procedures. Do the
corrective actions for each fault code. Refer to 767 FIM 28-41 FAULT TREE 851 Config
4 for applicable corrective actions for each fault. Repair and/or replace damaged FQIS
system wires and/or FQIS system components. Refer to 767 AMM 28-41-09 for in tank
FQIS Wiring Harness Inspection, removal and Installation. Refer to 767 AMM 28-41-01
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
22 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 23

for FQIS Tank Units, removal and Installation. Refer to 767 AMM 28-41-02 for FQIS
Compensator, removal and Installation. Refer to 767 AMM 28-41-03 for FQIS
Densitometer, removal and Installation. Refer to SWPM 20-10-13 as an accepted
procedure to repair electrical wires. Refer to 767 WDM 28-41-21, 767 WDM 28-41-22,
767 WDM 28-41-23, and SWPM 20-10-06.
NOTE: If any active fault codes listed in Table 1 were identified during the Fuel Quantity
Processor Unit interrogation, the airplane can be dispatched only if:
– It was positively determined that there are no shorts in the Center Wing
Tank.
– It was positively determined that the faults are outside the Center Wing
Tank.
Hard Faults (shorts) inside the tank should be troubleshooted and fixed before
further flights.
(3) Return to step 1 and repeat "Fuel Quantity BITE Procedure" until CONDITION 1: TEST
COMPLETE SELF TEST PASS is accomplished.
2. Get access to the Electrical System Card File, P50, in the EE Bay. Refer to 767 AMM 28-21-04
as an accepted procedure.
3. RC - Do the "Dry Capacitance Test for the Left Surge Tank Fuel Level Sensor, TS195". Refer to
767 FIM 28-21 FAULT TREE 805 as an accepted procedure. Refer to 767 WDM 28-21-12.
a. If the capacitance value is not between 6.50 to 8.05 picofarads, do corrective actions until the
"Dry Capacitance Test" is done and the capacitance value is between 6.50 to 8.05 picofarads.
4. RC - Do the "Dry Capacitance Test for the Right Surge Tank Fuel Level Sensor, TS196". Refer to
767 FIM 28-21 FAULT TREE 806 as an accepted procedure. Refer to 767 WDM 28-21-12.
a. If the capacitance value is not between 6.50 to 8.05 picofarads, do corrective actions until the
"Dry Capacitance Test" is done and the capacitance value is between 6.50 to 8.05 picofarads.
5. Close the Main Equipment Center access door to get access to the E2-4 electronics shelf. Refer
to 767 AMM 28-41-00 as an accepted procedure. Refer to 767 FIM 28-41-00 Config 4 for correction
of the fault messages.
6. Remove the electrical power to the airplane if it is not necessary. Refer to 767 AMM 24-22-00 as
an accepted procedure.
7. Put the airplane back to a serviceable condition.
Group 2:
PART 3: AIRPLANES WITH HONEYWELL FUEL QUANTITY INDICATING SYSTEM (FQIS) - FQIS
BITE CHECK AND SURGE TANK SENSOR DRY CAPACITANCE TEST
1. RC - Do PART 5: FUEL QUANTITY BITE PROCEDURE - HONEYWELL FQPU.
a. CONDITION 1: TEST COMPLETE FQIS FAULT NOT FOUND
NOTE: There are no faults within the FQIS system.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
23 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 24

(1) No further action is required.
(2) Continue with step 2.
b. CONDITION 2: TEST COMPLETE FQIS FAULT FOUND
NOTE: There are faults within the FQIS system.
(1) Identify the fault codes recorded during the Fuel Quantity BITE Procedure. If any of the
faults listed in "Table 2 - Honeywell FQIS Faults" are detected, they will have to be
corrected. Make a written record of all the FAULT messages shown.
Table 2 - Honeywell FQIS Faults
FIM Task (reference only)Most Probable FaultFault Code
28-41 TASK 854-855Left Aux Tank Unit No. 1 Low Resistance21
28-41 TASK 854-855Left Aux Tank Unit No. 2 Low Resistance22
28-41 TASK 854-855Left Aux Tank Unit No. 3 Low Resistance23
28-41 TASK 854-855Left Aux Tank Unit No. 4 Low Resistance24
28-41 TASK 854-855Right Aux Tank Unit No. 1 Low Resistance25
28-41 TASK 854-855Right Aux Tank Unit No. 2 Low Resistance26
28-41 TASK 854-855Right Aux Tank Unit No. 3 Low Resistance27
28-41 TASK 854-855Right Aux Tank Unit No. 4 Low Resistance28
28-41 TASK 854-855Left Aux Tank Unit No. 5 Low Resistance29
28-41 TASK 854-855Left Aux Tank Unit No. 1 Wiring71
28-41 TASK 854-855Left Aux Tank Unit No. 2 Wiring72
28-41 TASK 854-855Left Aux Tank Unit No. 3 Wiring73
28-41 TASK 854-855Left Aux Tank Unit No. 4 Wiring74
28-41 TASK 854-855Right Aux Tank Unit No. 1 Wiring75
28-41 TASK 854-855Right Aux Tank Unit No. 2 Wiring76
28-41 TASK 854-855Right Aux Tank Unit No. 3 Wiring77
28-41 TASK 854-855Right Aux Tank Unit No. 4 Wiring78
28-41 TASK 854-855Left Aux Tank Unit No. 5 Wiring79
28-41 TASK 854-855Aux Tank Compensator Low ResistanceC2
28-41 TASK 854-855Aux Tank Compensator WiringC5
(2) Do corrective actions for each fault code detected that is listed in "Table 2 - Honeywell
FQIS Faults". Refer to the Fault Code Index in 767 FIM 28-41 TASK 854 and/or 767 FIM
28-41 TASK 855 for applicable fault isolation procedures and corrective action. Repair
and/or replace damaged FQIS system wires and/or FQIS system components. Refer to
767 AMM 28-41-09 for in tank FQIS Wiring Harness Inspection, removal and Installation.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
24 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 25

Refer to 767 AMM 28-41-01 for FQIS Tank Units, removal and Installation. Refer to 767
AMM 28-41-02 for FQIS Compensator, removal and Installation. Refer to 767 AMM
28-41-03 for FQIS Densitometer, removal and Installation. Refer to SWPM 20-10-13 as
an accepted procedure to repair electrical wires. Refer to 767 WDM 28-41-21, 767 WDM
28-41-22, 767 WDM 28-41-23, and SWPM 20-10-06.
NOTE: The Honeywell FQIS processor unit will display applicable fault codes for all
tanks when a Lo-Z short to ground occurs for any one tank. Although service
bulletin requires to detect and correct the FQIS faults in the Center Tank before
puting the airplane in service, maintenance actions for Main Tanks might be
required to clear the fault codes for Center Tank for Lo-Z "short to ground"
condition.
NOTE: If any active fault codes listed in Table 2 were identified during the Fuel Quantity
Bite Procedure, the airplane can be dispatched only if:
– It was positively determined that there are no shorts in the Center Wing
Tank.
– It was positively determined that the faults are outside the Center Wing
Tank.
Hard Faults (shorts) inside the tank should be troubleshooted and fixed before
further flights.
(3) Return to step 1 and repeat the "Fuel Quantity BITE Procedure" until CONDITION 1:
TEST COMPLETE SELF TEST PASS is accomplished.
2. Get access to the Electrical System Card File, P50, in the EE Bay. Refer to 767 AMM 28-21-04
as an accepted procedure.
3. RC - Do the "Dry Capacitance Test for the Left Surge Tank Fuel Level Sensor, TS195". Refer to
767 FIM 28-21 FAULT TREE 805 as an accepted procedure. Refer to 767 WDM 28-21-12.
a. If the capacitance value is not between 6.50 to 8.05 picofarads, do corrective actions until the
"Dry Capacitance Test" is done and the capacitance value is between 6.50 to 8.05 picofarads.
4. RC - Do the "Dry Capacitance Test for the Right Surge Tank Fuel Level Sensor, TS196". Refer to
767 FIM 28-21 FAULT TREE 806 as an accepted procedure. Refer to 767 WDM 28-21-12.
a. If the capacitance value is not between 6.50 to 8.05 picofarads, do corrective actions until the
"Dry Capacitance Test" is done and the capacitance value is between 6.50 to 8.05 picofarads.
5. Close the Main Equipment Center access door to get access to the E2-4 electronics shelf. Refer
to 767 AMM 28-41-00 as an accepted procedure. Refer to 767 FIM 28-41-00 Config 4 for correction
of the fault messages.
6. Remove the electrical power to the airplane if it is not necessary. Refer to 767 AMM 24-22-00 as
an accepted procedure.
7. Put the airplane back to a serviceable condition.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
25 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 26

Group 1:
PART 4: FUEL QUANTITY BITE PROCEDURE - SIMMONDS/GOODRICH FQPU
1. Go into the main equipment center.
NOTE: The FQIS Processor BITE Display Board will come on during airplane power-up. The
menu will be inactive when you push the ON button on the Processor during this power-up
condition. The power-up will last approximately 90 seconds.
2. If necessary, install the E/E Access Hatch safety barrier across the opening in the electronics
access door.
NOTE: Do not push the RESET switch on the FQIS processor before you make a written record
of all fault codes. When you push the RESET switch, it erases all fault codes kept in the
FQIS processor memory.
3. FQIS "SELF TEST ?" procedure.
a. On the FQIS processor, push and hold the "ON/OFF" button for a minimum of one second.
b. Make sure the FQIS processor display shows "Present Faults ?".
c. Continue to push and release the "NO" button until the "Self Test ?" message shows.
d. Push and release the "YES" button.
e. When the message "Begin Self Test ?" shows, push and release the "YES" button.
NOTE: The self test will use 90 seconds, and the message "Test In Progress" will show.
f. Make sure the message "Test Complete Self Test Pass" shows on the display.
NOTE: If "Test Complete List Faults ?" shows on the display, push and release the "YES"
button first and the "DOWN" button next to see the fault messages. Continue to push
and release the "Down" button until all the fault messages are shown. Make a written
record of the fault messages shown. Refer to 767 FIM PAGEBLOCK 28-41-00 Config
4 for correction of the fault messages.
g. Push and release the "Down" button.
h. Make sure the message "End Of Self Test" shows on the display.
i. Push and release the "ON/OFF" button.
j. Make sure the FQIS processor display goes off.
Group 2:
PART 5: FUEL QUANTITY BITE PROCEDURE - HONEYWELL FQPU
1. Go into the main equipment center.
2. If necessary, install the E/E Access Hatch safety barrier across the opening in the electronics
access door.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
26 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 27

NOTE: Do not push the RESET switch on the FQIS processor before you make a written record
of all fault codes. When you push the RESET switch, it erases all fault codes kept in the
FQIS processor memory.
NOTE: To prevent nuisance fault codes and nuisance status codes for some processors, refer
to 767 AMM 28-41-00 "Fuel Quantity BITE Procedure."
3. Press Test Procedure
a. On the FQIS processor, push and hold the PRESS TEST switch for a minimum of one second
and a maximum of seven seconds.
b. Make sure the FQIS processor display shows the number 88.
c. Release the PRESS TEST switch.
d. Make sure the FQIS processor display goes off.
e. Move the DISPLAY CHAN SEL switch to the opposite position.
f. On the FQIS processor, push and hold the PRESS TEST switch for a minimum of one second
and a maximum of seven seconds.
g. Make sure the FQIS processor display shows the number 88.
h. Release the PRESS TEST switch.
i. Make sure the FQIS processor display goes off.
4. BIT Procedure
a. Push the BIT switch for one second and release.
b. Make a written record of the fault code shown on the FQIS processor display.
c. Continue to push and release the BIT switch while you make a written record of all fault codes
shown.
d. When the status code F8, F9, or 00 shows on the FQIS processor display, all of the fault
codes are shown.
e. Push the BIT switch for one second and release.
f. Make sure the FQIS processor display goes off.
5. RESET Procedure
a. Push the RESET switch for one second and release.
b. Make sure the FQIS processor display shows the status code F1.
c. After approximately 22 seconds, make sure the FQIS processor shows the status code F2.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
27 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 28

(1) If the FQIS processor display shows the status code F3, do the RESET procedure again.
NOTE: The FQIS processor display must show the status code F2 before you do the
VERIFY procedure.
6. VERIFY Procedure
a. Push the VERIFY switch for one second and release.
b. Make sure the FQIS processor display shows the status code F4.
c. After approximately 30 seconds, make sure the FQIS processor display shows the status
code F5 or F6.
d. Push the VERIFY switch for one second and release.
e. Make sure the FQIS processor display goes off.
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
28 of 30
BOEING SERVICE BULLETIN 767-28-0118

### Page 29 (OCR)

BOEING SERVICE BULLETIN 767-28-0118
FUEL QUANTITY
ACCESS DOOR  PROCESSOR UNIT
119AL  (FQPU)
(E2-4)
MAIN EQUIPMENT CENTER
DISPLAY
DISPLAY
MENU
BUTTONS
MENU
BUTTONS
HONEYWELL
SIMMONDS/GOODRICH
FUEL QUANTITY PROCESSOR UNIT
2339653
FIGURE 1: MAIN EQUIPMENT CENTER - FUEL QUANTITY PROCESSOR UNIT - INSPECT
(SHEET 1 OF 2)
Original Issue: July 15, 2014
Export Controlled ECCN: 9E991 - BOEING  767-28-0118
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.  29 of 30

### Page 30

The step numbers shown below agree with the numbers shown in the circle symbols in the figure. The QTY
numbers shown below are the number of parts necessary for each airplane.
MORE DATAQTYIDENTIFICATIONNAMETASKSTEP
SIMMONDS/ GOODRICH
FQPU. Use Group 1 instruc-
tions.1
S345N001-( )FUEL QUANTITY
PROCESSOR UNIT
INSPECT1
(a)
HONEYWELL FQPU. Use
Group 2 instructions.1
HG1057AA07;
HG1057ER02;
HG1057ER03;
HG1057LR02
FUEL QUANTITY
PROCESSOR UNIT
INSPECT2
(a)
(a) Inspect for part number.
FIGURE 1: MAIN EQUIPMENT CENTER - FUEL QUANTITY PROCESSOR UNIT - INSPECT
(SHEET 2 OF 2)
Export Controlled ECCN: 9E991 - BOEING
PROPRIETARY - Copyright © Unpublished
Work - See page 1 for details.
Original Issue: July 15, 2014
767-28-0118
30 of 30
BOEING SERVICE BULLETIN 767-28-0118

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.