### Page 1

Service Bulletin 215-A548July 15/11
Page 1 of 13 ATA Ref: 32-10
 
MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
LANDING GEAR
INSPECTION OF THE MAIN LANDING GEAR (MLG) UPPER MEMBER FORWARD LUG
USING EDDY CURRENT METHOD
1. Planning Information
A. Compliance
The inspection described in this Service Bulletin is Mandatory and must be completed within
the next 50 flight hours upon receipt of this Service Bulletin.
The inspection described in this Service Bulletin is to be repeated at or before every 165 land
landings until a permanent solution is incorporated in the Aircraft Maintenance Manual and/or
pending further instruction from your Amphibious Aircraft Technical Representative.
NOTE: This Service Bulletin is only applicable to aircraft in the condition as originally
delivered by Canadair and/or Bombardier Aerospace or as subsequently modified by
Canadair and/or Bombardier Aerospace Service Bulletin(s).  Prior to incorporation of
this Service Bulletin, the status of any related systems or structural modification(s)
introduced by Supplementary Type Approval (STA) or equivalent action must be
examined for compatibility with the modifications and test procedures (if applicable)
detailed in this Service Bulletin. 
B. Approval
The technical content of this Service Bulletin has been approved under the authority of the
Design Approval Organization No: DAO #93-Q-02.
C. Effectivity
CL−215−1A10 piston and CL−215−6B11 turboprop aircraft, Serial Nos. 1051 to1125.
D. Reason
Cracks have been detected on the forward main landing gear lugs in service.

### Page 2

MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
Service Bulletin 215-A548July 15/11
Page 2 of 13 ATA Ref: 32-10
 
E. Description
This Service Bulletin gives instruction to do an eddy current inspection on the forward lug part
numbers 160−714−3 (LH) and 160−714−4 (RH), without removing the MLG upper member.
F. Manpower
We estimate that it will take 1 technician approximately 2 hours to complete this Service
Bulletin.
NOTE: All NDT inspections must be done by certified level 2 or 3 individuals in an NDT
standard approved by the national Airworthiness authority.
G. Material Availability
No kit is necessary for this inspection.
H. Tool Availability
REFERENCE1.9 DESIGNATION
Hocking Phasec 2200
or equivalent
Eddy Current-Instrument-Impedance-Plane Type
AL29−32 Calibration reference standard made from aluminum alloy
(29% IACS), that contains 0.008 in. (0.20 mm), 0.020 in.
(0.51 mm), and 0.040 in. (1.02 mm) deep electrical dis-
charge machined (EDM) notches.
Commercially
available
Coaxial cable (microdot to BNC type)
Commercially
available
Surface probe, 45° tip, 500 kHz frequency, NFe/Fe, absolute,
shielded, 0.092 in. (2.34 mm) diameter, 4.50 in. (114.30 mm)
length, 0.750 in. (19.5 mm) tip length. (GE P/N 205P4XF or
equivalent)
Commercially
available
Explosion Proof Light
NOTES: 1. You can use equivalent eddy current equipment if it satisfies the requirements of
this procedure and is capable of resolving the reference notch in the calibration
reference standard at the required level of resolution and sensitivity.
2 To get access to the inspection area, it is permitted to use a surface probe of
different configuration from the one specified. The test frequency can range from
100 kHz to 500 kHz.

### Page 3

MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
Service Bulletin 215-A548July 15/11
Page 3 of 13 ATA Ref: 32-10
 
I. Weight and Balance
Not affected.
J. Electrical Load Data
Not affected.
K. References
For Bombardier Aerospace Reference only:
(Not Supplied with Kit)
Bombardier Aerospace Restriction and/or Special Instruction (RSI) C-3892, Revision, A.
L. Publications Affected
None.
M. Related Service Bulletin
Service Bulletin 215-547, Inspection of the Main Landing Gear Upper Member Forward Lug
Using Liquid Penetrant Inspection Method.
2. Accomplishment Instructions
NOTES: 1. For this modification, it is assumed that standard maintenance and repair practices
will be applied in accordance with applicable Product Support Publications (PSP).
2. For parts location, refer to the illustration page in this Service Bulletin.
3. If any deviation exists, contact your Amphibious Aircraft Technical Representative for
further instructions.

### Page 4

MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
Service Bulletin 215-A548July 15/11
Page 4 of 13 ATA Ref: 32-10
 
A. Preparation
For piston aircraft refer to PSP 296, Nondestructive Testing Manual, PART 1 GENERAL −
EDDY CURRENT, and Figure 2.
For turboprop aircraft refer to PSP 396, Nondestructive Testing Manual, PART 6 GENERAL −
EDDY CURRENT, and Figure 2.
The procedure for the left MLG upper member forward lug is described.  The procedure for the
right MLG upper member forward lug is similar.
WARNING: ENSURE PERSONNEL AND EQUIPMENT ARE CLEAR OF ALL
HYDRAULICALLY OPERATED SYSTEMS PRIOR TO REMOVING ELECTRICAL
POWER.  IF YOU DO NOT DO THIS INJURIES TO PERSONNEL AND
DAMAGE TO EQUIPMENT CAN OCCUR.
(1) Isolate electrical power and observe all safety precautions.
(a) For turboprop aircraft refer to PSP 392, Chapter 24 − ELECTRICAL POWER.
(b) For piston aircraft refer to PSP 292, Chapter 24 − ELECTRICAL POWER.
NOTE: It is not necessary to remove the MLG upper member to do this inspection.
(2) Make sure the inspection surface is clearly visible. Refer to Figure 3.
WARNING: WEAR RUBBER GLOVES, EYE PROTECTION, AND A RESPIRATOR WHEN
HANDLING SOLVENTS, SEALING COMPOUNDS, OR ADHESIVES.  CONTACT
WITH SOLVENTS, SEALING COMPOUNDS, OR ADHESIVES AND THEIR
VAPOURS MAY CAUSE IRRITATION TO THE SKIN, THE EYES, AND THE
LUNGS.  FAILURE TO WEAR PROPER PROTECTION MAY CAUSE INJURIES
TO PERSONNEL.
(3) Clean the areas to be inspected thoroughly with aliphatic naphtha using a nylon bristled
brush and clean cloths in accordance with PSP 297, Chapter 51. Allow the surfaces to
dry completely.
NOTE: If the paint or primer is in good condition, it does not need to be stripped. If the
finish is damaged, the bare metal must be exposed and refinished in accordance
with PSP 297, Chapter 51.

### Page 5

MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
Service Bulletin 215-A548July 15/11
Page 5 of 13 ATA Ref: 32-10
 
B. Equipment Calibration
Refer to Figures 1 and 2
NOTES: 1. Make sure that you follow the manufacturer’s instrument instructions when you
operate the test equipment.
2. The values listed in Figure 1 may vary between instruments.
(1) Connect the probe 205P4XF with the coaxial cable to the eddy current instrument.
(2) Turn the instrument ON and adjust and set the instrument controls as shown in Figure 1.
(3) Put the probe (coil) tip perpendicular to the surface of the AL29 −32 calibration reference
standard (CRS), away from the 0.040 in. (1,02 mm) deep EDM notch and the edge.
(4) Balance (BAL) the eddy current instrument.
(a) Adjust the instrument (PHASE) control to obtain a horizontal lift −off signal moving
from right−to−left (with increasing lift−off) across the screen display.
(b) Use the (X −POS) and (Y−POS) controls to position the dot in the lower right
quadrant of the screen display.
(5) Move the probe (coil) tip across the 0.040 in. (1,02 mm) deep EDM notch, and adjust the
instrument sensitivity (gain) to obtain an amplitude signal as shown in Figure 1, Screen
Display.
(6) Differentiate between the EDM notch and the edge signals by moving the probe over the
edge of the reference standard.
(a) Make sure the signal obtained from the edge slants −off towards the upper left
quadrant as shown in Figure 1.

### Page 6

MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
Service Bulletin 215-A548July 15/11
Page 6 of 13 ATA Ref: 32-10
 
C. Lift −Off Compensation Verification
Refer to Figures 1 and 2
(1) Put the probe (coil) tip perpendicular to the inspection surface.
NOTE: DO NOT balance the instrument.
(2) Compare the screen displays between the operating point on the inspection surface and
the balance point on the CRS for the following conditions:
(a) If the operating point on the inspection surface matches the balance point on the
CRS, no compensation for paint thickness is required:
1 Proceed to the Inspection Procedure section.
− or −
(b) If the operating point on the inspection area does not match the balance point on
the CRS, but has moved to the LEFT, compensation for the paint thickness is
required. Do as follows:
1 Attach a strip of nonconductive tape or shim to cover the CRS surface and the
EDM notches.
2 Put the probe (coil) tip perpendicular to the surface of the CRS. DO NOT balance
the instrument.
3 Compare the operating point on the inspection surface to the balance point on
the CRS for the conditions that follow:
− If the operating point on the inspection surface is still to the left of the balance
point on the CRS, add an additional strip of tape or shim until the balance
point on the CRS matches the inspection area.
− If the operating point on the CRS over the tape is to the right of the balance
point, remove a strip of tape or shim until the balance point on the CRS
matches the inspection area.
− If lift−off compensation and calibration requirements cannot be met, remove
the paint or coating prior to inspection.
(3) Slide the probe across the 0.040 in. (1,02 mm) EDM deep notch covered with tape on the
CRS.
(a) Adjust the GAIN to obtain an eddy current amplitude signal from the 0.040 in.
(1,02 mm) deep EDM notch as shown in Figure 1, Screen Display.
(b) Proceed to the Inspection Procedure section.

### Page 7

MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
Service Bulletin 215-A548July 15/11
Page 7 of 13 ATA Ref: 32-10
 
D. Inspection Procedure
Refer to Figure 3
NOTES: 1. Monitor the screen display carefully at all times and make a note of all distinct
relevant indications. Include the screen height of each signal and the related
location on the part being inspected.
2. A relevant crack indication is as follows:
− A fast up dot movement signal that stays at the up position for more than a
longer probe scan distance (more than one probe diameter) when a crack length
is parallel to the scan direction,
− a fast vertical deflection signal with a short probe scan distance (one probe
diameter or less) when the crack length is perpendicular to the scan direction.
3. After balancing the inspection area, if the balance point drops below the screen
display from the original balance point, it could indicate the original balance
location contains a defect. If this is true, rebalance on an adjacent area and scan
the original balance point for possible defects before continuing the inspection.
4. Instrument calibration verification intervals are as follows:
− Every 30 minutes of continuous operation,
− a change to set−up parameters, and/or equipment (i.e. a different probe),
− when the inspection is completed,
− when there is any variation in the amplitude of the calibration signal, calibrate the
instrument again and repeat the inspection at all locations from the last valid
calibration point.
5. Make sure the operation point is on the screen display at all times.
6. The maximum inspection scan speed shall be equivalent or less than the
calibration probe speed.
Refer to Figure 1 for typical screen responses and Figure 3 for inspection areas and scan
paths.
(1) Put the probe (coil) tip perpendicular to the inspection area as close as possible to the
shoulder of the initial machined fillet radius on the left MLG upper member forward lug
without getting an edge signal.
(2) Balance (BAL) the instrument.
(a) If necessary, adjust the instrument (PHASE) control to obtain a horizontal lift −off
signal moving from right−to−left across the screen display.

### Page 8

MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
Service Bulletin 215-A548July 15/11
Page 8 of 13 ATA Ref: 32-10
 
(3) Make a series of contour scans parallel to the shoulder adjacent to the machined fillet
radius extending for 0.250 in. (6,35 mm) from the machined fillet radius juncture.
(a) Make sure you maintain a constant edge distance for the initial scan on the shoulder
adjacent to the machined fillet radius.
(b) Make sure the probe tip stays perpendicular to the inspection surface at all times
during the scan.
(c) Index one probe diameter or less from the previous scan. Refer to Figure 3 for
inspection location and for typical scan path.
(4) Repeat the inspection procedure for the opposite shoulder of the MLG upper member
forward lug.
(5) Repeat the inspection procedure for the right-hand (RH) MLG upper member forward lug.
E. Evaluation of Indications
(1) Further investigation is required if:
(a) there is a distinct vertical deflection signal that occurs over a short scan distance
(one probe tip diameter), or
(b) there is a rapid up dot movement signal that stays at the up position over a longer
scan distance.
(2) If you have a suspect indication, make sure it is not caused by non-relevant factors, as
follows:
− edge effect,
− an abrupt change in geometry,
− localized variations in conductivity,
− permeability, or
− other non−relevant factors.
(3) Evaluate all suspect crack indications by comparing their phase angle, amplitude and
shape to the calibration standard EDM notch signal.
(4) If a crack is detected, determine the length and location of the crack.

### Page 9

MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
Service Bulletin 215-A548July 15/11
Page 9 of 13 ATA Ref: 32-10
 
F. Acceptance or Rejection Criteria
Refer to Figures 1 and 3
(1) Indications of a crack are as follows:
(a) A distinct vertical deflection signal that occurs over a short scan distance (one probe
tip diameter),
(b) a distinct vertical deflection signal which equals to 50% or greater than the response
from the 0.040 in. (1,02 mm) deep EDM notch as shown in Figure 1,
(c) a rapid upward dot movement signal which equals to 50% or greater than the
response from the 0.040 in. (1,02 mm) deep EDM notch as shown in Figure 1 and
remains at the upward position momentarily (or over a longer period of time).
(2) If there are  no cracks,
− repeat the Eddy Current Inspection every 165 Land Landings.
(3) If there is a  crack,
− provide details of findings to your Amphibious Aircraft Technical Representative,
− replace the forward lug (160−714−3 or 160−714−4), as per PSP 298, MAIN LANDING
GEAR UPPER AND LOWER MEMBERS − DISASSEMBLY/ASSEMBLY.
− repeat the Eddy Current Inspection every 165 Land Landings.
G. Close −Out
(1) Replace any finish that was removed from the inspection area. Refer to PSP 297,
Stuctural Repair Manual, Chapter 51−52−16, CORROSION PREVENTIVE TREATMENT
− GENERAL PROCEDURES.
(2) Remove all tools, equipment, and unwanted materials from the work area.
(3) Restore the electrical power.
(a) For turboprop aircraft refer to PSP 392, Chapter 24 − ELECTRICAL POWER.
(b) For piston aircraft refer to PSP 292, Chapter 24 − ELECTRICAL POWER.
H. Recording
When this Service Bulletin is completed, make the entry in the aircraft technical record and
send back the attached Incorporation Notice to Amphibious Aircraft Technical Publications.

### Page 10

MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
Service Bulletin 215-A548July 15/11
Page 10 of 13 ATA Ref: 32-10
 
AND PROBE 205P4XF)
FIGURE 1
..
.
. .... ....
. . .... ....
.
.
.
. . ... ....
. . .... ....
. . .... ....
.
.......
.
.
.
.
SCREEN DISPLAY
EDGE SIGNAL
INSTRUMENT SETTINGS
SIGNAL FROM 0.040 −in. (1,02 −mm)
DEEP EDM NOTCH
LIFT −OFF SIGNAL
BALANCE POINT
100%
0%
80 % FSH
MODE
DISPLAY
VIEW
CH 1 FREQ
CH 1 PHASE
GAIN
X:Y
HI−PASS
LO−PASS
BAL. LOAD
X−POS
Y−POS
ABS CH1
XY
CH 1
500 kHz
342.0
44.5 dB
X −8 dB
DC
200 Hz
47   H
40
−40
.. ....
CALIBRATION DATA (HOCKING PHASEC 2200 EDDY CURRENT INSTRUMENT
μ

### Page 11

MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
Service Bulletin 215-A548July 15/11
Page 11 of 13 ATA Ref: 32-10
 
3.75 in.
0.75 1.00
1.50 in.
(1,02 mm)
NOTES
4
2.
0.005 in. +0.000/−0.002 in.
(0,127 mm +0,000/−0,051 mm)
(0,51 mm) (0,20 mm)
0.040 0.020 0.008
AL 29.32 4
0.75
0.25 in.
Material: 2024−T3, QQ−A−250/41.
Finish surface 125 RMS or better.
(19,05 mm)(19,05 mm) (25,40 mm)
(95,25 mm)
WIDE X 1.50 in. (38,10 mm)
LONG EDM NOTCH
(38,10 mm)
(TYPICAL)
0.040 in. 0.020 in. 0.008 in.
(6,35 mm)
3. Penetrant inspect as per BAPS 176 −002.
4. Identification sticker, 0.125 in (3,175 mm) letters black colour.
5. Conductivity test as per BAPS 168 −013.
6. EDM notches shall have a tolerance of    0.001 in. (  0.025 mm)
for depth and +0.000/0.002 in. (+0,000/−0,051 mm) for width.
−+ −+
CALIBRATION REFERENCE STANDARD AL 29−32
FIGURE 2

### Page 12

MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
Service Bulletin 215-A548July 15/11
Page 12 of 13 ATA Ref: 32-10
 
INSPECTION LOCATION OF THE MAIN LANDING GEAR (MLG) FORWARD LUG SHOULDERS
FIGURE 3
LH MLG
UPPER MEMBER
Inspect 0.250 in. (6,35 mm) from the
Machined Filet Radius Juncture
0.250 in.
0.250 in.
0.250 in.
Reference: Machined Filet Radius
Typical for Both Sides
Typical Inspection Area for
Both Shoulders adjacent to
the Machined Filet Radius
NOTES
Dash Lines Represent
Typical Scan Paths
Typical Crack Location
0.250 in.

### Page 13

MODEL CL-215-1A10
MODEL CL-215-6B11
ALERT
SERVICE BULLETIN
Service Bulletin 215-A548July 15/11
Page 13 of 13 ATA Ref: 32-10
 
3. Material Information
This Service Bulletin contains no kit.
A. The following materials, or equivalent, are necessary to do this Service Bulletin. You can buy
them locally:
DESCRIPTION PART NO./NAME SPECIFICATION QUANTITY
Alodizing Solution Alodine 1200S MIL-C-81706 
Class 1A
A/R
Aerodynamic 
Sealant
Pro Seal 870
Class B−2
MIL-S-81733 
Type 2
A/R
Aliphatic Naphtha TT-N-95 Type 2
Faying Surface
Sealant
Pro Seal 870
Class C
MIL-S-81733 
Type 4
A/R
Humiseal 1B15 A/R
Fluid Resistant Epoxy
Primer
BAMS 565-01 A/R
Fluid Resistant Epoxy
Topcoat
BAMS 565-02 A/R

### Page 14

Upon completion of Service Bulletin(s), please fill in and return by fax to:
Service Bulletin Number(s) Rev.
Aircraft Serial No.
Date of Incorporation
Aircraft Reg. No.
Technical Publication,
Dept. 649-DBF−(9)
Bombardier Aerospace
Amphibious Aircraft
St. Laurent, Quebec
Fax No.: (514) 855−7602
Airframe Hours
Remarks
Name
SERVICE BULLETIN
INCORPORATION NOTICE
REPLY FAX
Customer/Operation
(Please Print)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.