# Bombardier Alert Service Bulletin A670BA-24-020: Revision C

- Rights: © Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2010-0550; AD 2010-20-19 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Bombardier Alert Service Bulletin A670BA-24-020](https://openairdocs.org/service-documents/bombardier/a670ba-24-020.md)
- Title as filed: U.S. DOT/FAA - Service Information - 2
- Pages: 12
- PDF: https://openairdocs.org/files/sha256/38/b3/38b330c8c3effe35b4ca94e410443151324990f959aa1c6e862d7b0861dbc59c
- Page: https://openairdocs.org/service-documents/bombardier/a670ba-24-020/file/38b330c8c3ef

## Text

This text is OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1 (OCR)

BOMBARDIER
SERVICE BULLETIN
REVISION TRANSMITTAL SHEET
CL-600-2C10, CL-600-2D15 and CL-600-2D24
CANADAIR REGIONAL JET (CRJ) AIRCRAFT
ALERT SERVICE BULLETIN A670BA-24-020
SUBJECT: Electrical Power System - Emergency AC Power Generation System - Specia
Detailed Inspection of the Air Driven Generator (ADG) Stru
This page transmits:
Revision C of Alert Service Bulletin A670BA-24-020,
pages 1 thru 9, dated April 20/2009.
The changes in this revision have no effect on aircraft that have incorporated a
previous issue of this service bulletin.
Reason:
Revised Planning Information, paragraph 1., to:
Change the Hamilton Sundstrand service bulletin revision to 3.
This revision also includes small editorial changes that do not have an effect on the
technical content.
Document Instructions:
Discard the copy of Alert Service Bulletin A670BA-24-020, Revision B, dated Dec
07/2006. Replace with the copy attached.
Service Bulletin History:
Initial issue, dated Apr 20/2005.
Revision A, dated May 17/2005.
Revision B, dated Dec 07/2006.
Apr 20/2009  S.B. A670BA-24-020
Page 1 of 1

### Page 2 (OCR)

BOMBARDIER
ALERT SERVICE BULLETIN
Technical
Publications
THIS SERVICE BULLETIN IS SENT TO EACH OPERATOR. IF THE OPERATOR HAS LEASED AIRCRAFT,
THIS SERVICE BULLETIN MUST BE SENT TO THE LESSEE. IF THE OPERATOR HAS SOLD AIRCRAFT OR
TRANSFERRED SPARES IN THE LAST SIX MONTHS, THIS SERVICE BULLETIN MUST BE SENT TO THE
NEW OWNER, UNLESS CONFIRMATION WAS RECEIVED THAT BOMBARDIER COMMERCIAL AIRCRAFT
DIVISION HAS INCLUDED THE NEW OPERATOR ON THE DISTRIBUTION LIST.
ATA SYSTEM: 24-23  NUMBER: A670BA-24-020
SUBJECT:  Electrical Power System - Emergency AC Power Generation System -
Special Detailed Inspection of the Air Driven Generator (ADG) Strut
1. PLANNING INFORMATION
A. Effectivity
(1) Aircraft Affected:
Service Bulletin:  CL-600-2C10 Canadair Regional Jet (CRJ)
Aircraft Serial Numbers 10003 thru 10260.
NOTE: The inspection in this service bulletin was done on Aircraft Serial
Numbers 10003 and 10201 thru 10260 after Certificate of
Airworthiness and before delivery.
Production:  There is no production effectivity
Service Bulletin:  CL-600-2D15 Canadair Regional Jet (CRJ) and
CL-600-2D24 Canadair Regional Jet (CRJ)
Aircraft Serial Numbers 15001 thru 15106
NOTE: The inspection in this service bulletin was done on Aircraft Serial
Numbers 15031 thru 15106 after Certificate of Airworthiness and
before delivery.
Apr 20/2005  S.B. A670BA-24-020
Revision C, Apr 20/2009  Page 1 of 9

### Page 3 (OCR)

ALERT SERVICE BULLETIN A670BA-24-020
Production:  There is no production effectivity.
NOTE: The instructions in this Service Bulletin are only applicable to the
systems and parts installed at the time of delivery of the aircraft or
as changed by Bombardier Aerospace Service Bulletin(s). Before
you do this bulletin, examine all STC, STA or equivalent action
changes to make sure this bulletin can be completed.
B. Reason
(1) Condition
It is possible for a crack to start on the aft area of the strut assembly of the
ADG.
(2) Evidence
During an inspection of the ADG, damage was found on the strut of one
ADG in the area adjacent to the generator.
(3) Objective/Benefit
This service bulletin gives instructions to do a special detailed inspection of
the ADG and, if necessary, to replace the ADG.
C. Description
Circuit breakers are opened and tagged. The ADG is lowered. The Hamilton
Sundstrand service bulletin ERPS10AG-24-3 is done. If damage is found, the
ADG is replaced and the damaged ADG is sent to Hamilton Sundstrand. The
ADG Is retracted to the stow position. If the ADG was replaced, an ADG
clearance checks and functional test of the ADG is done. The circuit breakers are
closed.
D. Compliance
Alert Service Bulletin.
Bombardier Aerospace recommends that this service bulletin be done no more
than 1000 flight hours from the release date on this service bulletin unless
otherwise directed by the airworthiness authority of the operator.
E. Approval
The technical content of this Service Bulletin has been approved under the
authority of the TCCA Design Approval Organization No: DAO #93-Q-02.
Apr 20/2005  S.B. A670BA-24-020
Revision C, Apr 20/2009  Page 2 of 9

### Page 4 (OCR)

ALERT SERVICE BULLETIN A670BA-24-020
F. Manpower
The man-hours given below are an estimate for direct labor done by an
experienced crew on an aircraft prepared for maintenance.
This estimate does not include the time necessary for:
- Administrative tunctions such as planning, liaison, familiarization, and
report writing.
- Non productive elapsed time such as rest time, having meals, and crew
shift changes.
- Elapsed time such as for paint to dry, sealant to cure, and fuel tank
venting.
- Preparation for modification (unless specified in the accomplishment
instructions) such as cleaning and getting parts, tools, consumables, and
ground equipment.
- Quality assurance inspections, troubleshooting and/or correction of
discrepancies found when a task is done.
- All other activities that are not considered by Bombardier Aerospace as
directly related to the accomplishment of this procedure.
It will take an estimated 0.5 man-hours to complete this service bulletin. The
man-hours are divided as shown in the table that follows:
TASK  MAN-HOURS
(1) Job Set-Up  0.25
(2) Procedure  N/A
(3) Test  N/A
(4) Job Close-Out  0.25
NOTE: This estimate does not include the man-hours necessary to do
Hamilton Sundstrand Service Bulletin ERPS10AG-24-3.
NOTE: The man-hours to replace the ADG, do the functional test and the
clearance checks are not shown in the table. If it is necessary to replace
the ADG, add 4.0 man-hours to replace the ADG and to do the related
Apr 20/2005  S.B. A670BA-24-020
Revision C, Apr 20/2009  Page 3 of 9

### Page 5 (OCR)

ALERT SERVICE BULLETIN A670BA-24-020
G. Material - Price and Availability
Refer to Hamilton Sundstrand Service Bulletin ERPS10AG-24-3.
H. Tooling - Price and Availability
Refer to Hamilton Sundstrand Service Bulletin ERPS10AG-24-3.
I. Weight and Balance
Not changed.
J. Electrical Load Data
Not changed.
K. References
- Restriction and/or Special Instruction (RSI), C-24-0455-00, Revision F.
- Aircraft Maintenance Manual (AMM), CSP B-001, Revision 16.
- Hamilton Sundstrand Service Bulletin ERPS10AG-24-3, Revision 3,
dated Mar 12/09.
- For Bombardier Aerospace reference only: PCA 71702.
L. Other Publications Affected
- Aircraft Maintenance Manual (AMM), CSP B-001.
M. Relationship Chart
Not applicable.
Apr 20/2005  S.B. A670BA-24-020
Revision C, Apr 20/2009  Page 4 of 9

### Page 6 (OCR)

ALERT SERVICE BULLETIN A670BA-24-020
2. ACCOMPLISHMENT INSTRUCTIONS
A. Job Set-Up
(1) Reference Information
REFERENCE  DESIGNATION
AMM 12-00-00-867-801  Standard Aircraft Configuration for
Maintenance
AMM 24-00-00-910-801  Electrical/Electronic Safety
Precautions
AMM 24-23-01-000-801  Removal of the ADG
AMM 24-23-01-220-801  Clearance Checks of the ADG
AMM 24-23-01-400-801  Installation of the ADG
AMM 24-23-01-720-801  Functional Test of the ADG
(On-Ground)
AMM 24-23-01-840-801  Extension of the ADG
AMM 24-23-01-840-802  Retraction of the ADG
AMM 29-00-00-910-801  Hydraulic Safety Precautions
(2) Make sure that the aircraft is in standard configuration for maintenance
(AMM 12-00-00-867-801).
WARNING:  OBEY ALL THE HYDRAULIC SAFETY PRECAUTIONS WHEN
YOU DO WORK ON ANY HYDRAULIC SYSTEM OR ON A
HYDRAULIC SYSTEM COMPONENT. IF YOU DO NOT OBEY
THE SAFETY PRECAUTIONS, YOU CAN CAUSE INJURY TO
PERSONS AND/OR DAMAGE TO EQUIPMENT.
(3) Obey all the hydraulic safety precautions (AMM 29-00-00-910-801).
WARNING: OBEY ALL THE SAFETY PRECAUTIONS WHEN YOU DO
MAINTENANCE ON OR NEAR ELECTRICAL/ELECTRONIC
EQUIPMENT. YOU CAN CAUSE INJURY TO PERSONS AND/OR
DAMAGE TO EQUIPMENT.
(4) Obey all the electrical/electronic safety precautions (AMM
24-00-00-910-801).
Apr 20/2005  S.B. A670BA-24-020
Revision C, Apr 20/2009  Page 5 of 9

### Page 7 (OCR)

ALERT SERVICE BULLETIN A670BA-24-020
(5) Open, safety, and tag the circuit breakers that follow:
CB-PANEL  CB NO.  NAME
CBР-2  N6  ADG DEPLOY AUTO
CBP-2  N7  ADG DEPLOY MAN
(6) If not deployed, do an extension of the ADG (AMM 24-23-01-840-801).
B. Procedure
Refer to Figure 1.
(1) Do the Hamilton Sundstrand Service Bulletin ERPS10AG-24-3 (Fluorescent
Penetrant Inspection).
(2) If a crack is found do as follows:
(a) Remove the ADG (AMM 24-23-01-000-801).
(b) Return the damaged part to the address below:
Hamilton Sundstrand
4747 Harrison Avenue
P.O. Box 7002
Rockford, IL 61125
Attention: Repair Administration
Mail Stop 265-6
Phone: 815-226-6849
Fax: 815-226-6826
(c) Install the new ADG (AMM 24-23-01-400-801).
Apr 20/2005  S.B. A670BA-24-020
Revision C, Apr 20/2009  Page 6 of 9

### Page 8 (OCR)

ALERT SERVICE BULLETIN A670BA-24-020
AIR DRIVEN
GENERATOR
rsb601/24120 001.da. om. 06/04/05
Detailed Inspection on the ADG
Figure 1
Apr 20/2005  S.B. A670BA-24-020
Revision C, Apr 20/2009  Page 7 of 9

### Page 9 (OCR)

ALERT SERVICE BULLETIN A670BA-24-020
C. Job Close-Out
(1) If the ADG was not replaced do as follows:
(a) Do a retraction of the ADG (AMM 24-23-01-840-802).
(b) Remove the tags and close the circuit breakers that follow:
CB-PANEL  CB NO.  NAME
CBP-2  N6  ADG DEPLOY AUTO
CBP-2  N7  ADG DEPLOY MAN
(2) If the ADG was replaced do as follows:
(a) Do the ADG clearance checks (AMM 24-23-01-220-801).
(b) Remove the tags and close the circuit breakers that follow:
CB-PANEL  CB NO.  NAME
CBP-2  N6  ADG DEPLOY AUTO
CBP-2  N7  ADG DEPLOY MAN
(c) Do the functional test of the ADG (AMM 24-23-01-720-801).
(3) Remove all tools, equipment, and unwanted materials from the work area.
(4) When this service bulletin is completed, make this entry in the applicable
logbook(s) as follows: "Alert Service Bulletin A670BA-24-020, Revision C,
Electrical Power System - Emergency AC Power Generation System -
Special Detailed Inspection of the Air Driven Generator (ADG) Strut,
incorporated."
Apr 20/2005  S.B. A670BA-24-020
Revision C, Apr 20/2009  Page 8 of 9

### Page 10 (OCR)

ALERT SERVICE BULLETIN A670BA-24-020
3. MATERIAL INFORMATION
A. Kit Information
None.
B. Rotable Information
Refer to Hamilton Sundstrand Service Bulletin ERPS10AG-24-3.
C. Consumable Information
For a list of consumables, refer to the different tasks and the Hamilton Sundstranc
Service Bulletin given as references in this service bulletin.
D. Special Tools and Equipment
For as of Sed lian dein this refer toes fence sand the Hamilton
E. Disposition of Parts
Not applicable.
Apr 20/2005  S.B. A670BA-24-020
Revision C, Apr 20/2009  Page 9 of 9

### Page 11 (OCR)

BOMBARDIER
SERVICE BULLETIN EVALUATION FORM/COMPLIANCE SHEET
(YOUR IDEAS WILL HELP US PROVIDE BETTER BULLETINS)
SERVICE BULLETIN: A670BA-24-020  ISSUE: C
STRONGLY  DISAGREE NEUTRAL  AGREE  STRONGLY
DISAGREE  AGREE
• Instructions to do the Service Bulletin  •
were accurate.
Comments:
• Illustration(s), figure(s), picture(s) and/or
kit drawing(s) were helpful to carry out
instructions.
Comments:
• If a parts kit was required, did the kit  J
contents received agree with the
contents listed in the bulletin?
Comments:
• Aircraft hands-on work was  J
accomplished in estimated time.
Comments:
• Overall, I was satisfied with this Service
Bulletin.
Comments:
PLEASE SUPPLY US WITH THE FOLLOWING DATA AND FAX TO (450) 476-7300:
OPERATOR:  NAME (Please print)
SERVICE CENTER:  TELEPHONE:
AIRCRAFT SERIAL NO.:  FACSIMILE:
DATE OF SB
INCORPOARTION
THANK YOU FOR ANSWERING THIS EVALUATION FORM
UPON COMPLETION OF THIS EVALUATION FORM/COMPLIANCE SHEET, FAX TO
450-476-7300

### Page 12

(No text on this page.)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.
