# Bombardier Service Bulletin 604-30-007

Copy: Revision 1 ("SB 604-30-007"), 24 pages: PDF https://openairdocs.org/files/sha256/2d/ba/2dba5d661279d43c94810b2a20fcc2dc8acecbc558a01e217ead010a4e76f6ad; text https://openairdocs.org/service-documents/bombardier/sb-604-30-007/file/2dba5d661279.md. Rights: © Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2022-0090; AD 2022-09-01 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Bombardier](https://openairdocs.org/service-documents/bombardier.md)
- Type: Service bulletin (Service Bulletin)
- Number: 604-30-007
- Latest revision known: 604-30-007, Revision 1, dated January 29, 2019 (OpenAirDocs)
- Page: https://openairdocs.org/service-documents/bombardier/sb-604-30-007

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2022-09-01](https://openairdocs.org/ad/2022-09-01.md), effective May 31, 2022: Revision 1

Also cited in [1 proposed AD](https://openairdocs.org/service-documents/bombardier/sb-604-30-007/proposed.md).

## Text (24 pages)

Rights: © Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2022-0090; AD 2022-09-01 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

Discard the Basic Revision of this Service Bulletin dated Mar 27/2018, and replace in its
entirety with this Revision 01.
Service Bulletin No. 604 −30−007
Date of Basic Issue Mar 27/2018
Revision No. 01 Dated Jan 29/2019
For action applicable to aircraft on which the Basic Issue of this Service Bulletin was
done, refer to the retroactive action box on Page 1 of this Service Bulletin.
This revision is a complete reissue, therefore the revision bars were intentionally omitted.
This revision is issued to update the Service bulletin per the latest Drawing BAS63028157
and BAS63038360.
1. Revise Summary Sheet to change CAW to NO.
2. Add the retroactive action box to add action to Basic Issue.
3. Change, Paragraph 1.K., References.
4. Revise, Paragraph 2., Accomplishment Instructions.
5. Revise, Paragraph 3.B,, to update Parts.
6. Revise the Drawing BAS63028157 to Rev. C and Drawing BAS63038360 to Rev. B.
7. Make miscellaneous minor changes, as necessary, with no change of context.
SERVICE BULLETIN
MODEL CL−600−2B16
604−30−007
Page 1 of 1
REVISION TRANSMITTAL SHEET

### Page 2

SPECIAL CHECK/MODIFICATION - POTABLE WATER SYSTEM/WATER LINE
HEATERS - WATER LINE RIBBON HEATERS WIRING
The information below is provided for your reference. For full details, including labor and part
coverage, please see corresponding paragraph contained within this bulletin.
RECOMMENDED
SPECIFIED TIME COMPLIANCE
COMPLIANCE TIME
Within 6 Years from SB Release (Basic
Issue).
EFFECTIVITY: See Paragraph 1. A.
MANPOWER: 10 to 60 Man−Hours (See Planning Information).
CONTINUED AIRWORTHINESS (CAW)
FLEET CAMPAIGN NOYES
TLMC, CH 5 AFFECTED NOYES
KITS and/or PARTS YES NO
TOOLING/GSE YES NO
PLANNING INFORMATION: See important
information at the start of Paragraph 1. YES NO
DEDICATED SCHEDULE NOYES
PREREQUISITE SERVICE BULLETINS: N/A
To place an order for parts or kits, please call Bombardier Aerospace Parts Services
at: 514−855−2999 or 1−866−538−1247
SERVICE BULLETIN SUMMARY
my.businessaircraft.bombardier.com
MODEL CL−600−2B16
ATA 30−71, 38−10
ICE AND RAIN PROTECTION & WATER/WASTE
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
Page 1 of 1
This Service Bulletin is available at:

### Page 3

SPECIAL CHECK/MODIFICATION - POTABLE WATER SYSTEM/WATER LINE
HEATERS - WATER LINE RIBBON HEATERS WIRING
RETROACTIVE ACTION
1. RETROACTIVE ACTION APPLICABLE TO AIRCRAFT THAT HAVE
INCORPORATED THE BASIC ISSUE OF THIS SERVICE BULLETIN:
− THE AIRCRAFT THAT HAVE INCORPORATED THE BASIC ISSUE OF THE
SERVICE BULLETIN MUST DO REVISION 1 OF THIS SERVICE BULLETIN
TO COMPLY WITH TCCA AIRWORTHINESS DIRECTIVE.
1. PLANNING INFORMATION
NOTES:1 . Before you do this Service Bulletin, examine all STC, STA or
equivalent action changes to make sure that this Service Bulletin can
be completed.
2. The estimated range of man −hours given is based on the configuration
and location of the ribbon heater installation, which is different on each
aircraft. Possible downtime allocation planning may be needed to take into
account the possible unexpected repairs such as heat damaged
insulation.
3. Due to the lead −time required for obtaining kits and parts, operators are
advised to order the kits and parts in advance before scheduling the
incorporation of this Service Bulletin. Please contact Bombardier
Aerospace Parts Services, in Montreal, for delivery lead times and
confirmation of prices.
SERVICE BULLETIN
my.businessaircraft.bombardier.com
MODEL CL−600−2B16
ATA 30−71, 38−10
ICE AND RAIN PROTECTION & WATER/WASTE
Refer to applicable governmental agency regulations and requirements and make sure that the work described in this
Service Bulletin is performed in compliance with manufacturer’s recommendations and/or acceptable industry standards.
This document is proprietary to Bombardier Inc. and/or its affiliates and may not be reproduced or copied in any form or
by any means without the prior written consent of Bombardier Inc. and/or its affiliates.
© 2018−2019 Bombardier Inc.  All rights reserved
Learjet, Challenger, Global, are registered trademarks of Bombardier Inc. or its subsidiaries.
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
P a g e1o f2 0
This Service Bulletin is available at:

### Page 4

A. Effectivity
CL−600−2B16 aircraft, Serial No. 5301, 5302, 5303, 5304, 5306, 5307, 5308, 5309,
5310, 5316, 5317, 5318, 5320, 5321, 5324, 5332, 5333, 5335, 5336, 5337, 5338,
5341, 5342, 5343, 5346, 5347, 5348, 5349, 5352, 5353, 5357, 5358, 5359, 5366,
5367, 5369, 5372, 5373, 5376, 5377, 5378, 5379, 5380, 5381, 5382, 5384, 5385,
5386, 5387, 5388, 5389, 5390, 5393, 5394, 5395, 5396, 5398, 5399, 5400, 5402,
5403, 5405, 5407, 5408, 5409, 5411, 5413, 5415, 5416, 5417, 5418, 5419, 5421,
5422, 5423, 5424, 5425, 5427, 5428, 5430, 5431, 5432, 5433, 5434, 5436, 5438,
5439, 5440, 5441, 5442, 5444, 5445, 5446, 5447, 5449, 5450, 5451, 5453, 5455,
5457, 5459, 5460, 5461, 5464, 5465, 5466, 5467, 5468, 5469, 5470, 5471, 5472,
5474, 5475, 5476, 5477, 5478, 5479, 5481, 5482, 5483, 5484, 5485, 5487, 5488,
5489, 5490, 5491, 5493, 5495, 5496, 5497, 5498, 5499, 5500, 5502, 5503, 5506,
5508, 5509, 5510, 5511, 5512, 5513, 5514, 5515, 5516, 5517, 5520, 5521, 5522,
5523, 5524, 5525, 5526, 5527, 5529, 5530, 5531, 5532, 5534, 5536, 5537, 5538,
5539, 5540, 5541, 5542, 5543, 5544, 5545, 5546, 5547, 5548, 5549, 5550, 5552,
5553, 5554, 5555, 5557, 5558, 5560, 5561, 5562, 5563, 5564, 5565, 5566, 5567,
5569, 5570, 5572, 5574, 5575, 5576, 5577, 5579, 5580, 5581, 5582, 5583, 5584,
5585, 5586, 5587, 5589, 5591, 5594, 5595, 5596, 5598, 5599, 5601, 5602, 5603,
5604, 5605, 5608, 5611, 5613, 5619, 5621, 5622, 5623, 5628, 5629, 5630, 5634,
5635, 5636, 5639, 5644, 5645, 5647, 5648, 5650, 5655, 5656, 5659 and 5664.
NOTE: The instructions given in this Service Bulletin are only applicable to the
systems and parts installed at the time of delivery of the aircraft or as
changed by Bombardier Aerospace Service Bulletin(s).
(1) This modification is applicable to aircraft that have the COX & CO. 3043 Series
ribbon heaters installed through one of the following drawings:
NOTE: If water lines are not equipped with COX & CO. 3043 Series Ribbon
heater, no further action is required.
− Bombardier Drawing TM453071−XX “W/D EL Water Heaters”.
− Innotech Aviation Drawing WDBXXXX−XXX “W/D − Water Heaters, Galley
and Vanity”.
− Bombardier Drawing 6043070004 ”W/D − Water Line Heater System”.
− Bombardier Drawing 6043070005 “W/D − Water Line Heater System −
Small Lavatory”.
− Bombardier Drawing BAS6302XXXX “W/D Water Heater Modification”.
− Bombardier Drawing BAS6302XXXX “W/D − Ribbon Heater Installation
Modification”.
B. Reason
During a maintenance activity on a CL−604 aircraft, smoke was detected in the
AFT cabin (FS591). Materials surrounding the water line were burnt and damaged.
The probable cause was found to be a faulty drain line Cox & Co. ribbon heater
where circuit breaker CB2−D5 did not trip and the ribbon heater thermostat was
well functioning. The ribbon heater leads were not identified to verify proper
installation.
MODEL CL−600−2B16
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
P a g e2o f2 0

### Page 5

This Service Bulletin gives instructions to inspect the water line insulation, ribbon
heaters and wiring. A fuse is installed in−line with the ribbon heater. If required, the
ribbon heater wiring is corrected and the ribbon heater and/or insulation is replaced
if evidence of damage is found.
C. Description
This Service Bulletin gives instructions to:
− Get access to the potable water−line ribbon heaters and insulation between
FS335.00 and FS621.00 (RHS),
− Inspect the potable water−line ribbon heater insulation,
− If necessary, replace water line ribbon heaters and insulation,
− Inspect water line heater wiring pigtail for distinctive identification. Apply
identification,
− Install fuse holder and fuse at water line heater,
− Verify water line heater wiring pigtail installation is correct, and
− Do an operational test of the potable water system including water line heaters.
D. Compliance
Recommended within 6 years from this Service Bulletin release date (Basic Issue).
NOTE: If it is not possible to complete all the instructions in this Service Bulletin
because of the configuration of the aircraft, submit an SRPSA for analysis
and get an approved disposition to complete this Service Bulletin.
E. Approval
The technical content of this Service Bulletin has been approved under the
authority of Transport Canada Supplemental Type Certificate number SA17−80,
FAA Supplemental Type Certificate number ST03961NY and EASA Supplemental
Certificate number 10063991.
F. Manpower
NOTES: 1. The man −hours given are estimates to help you schedule the tasks
given in this bulletin. The estimates are for direct labor performed by
an experienced crew and do not include the time for familiarization,
planning, aircraft preparation in hangar such as towing and
positioning of scaffolds, removal of interior furnishings, repainting,
supervision and inspection.
For more information related to the manpower estimates, refer to
SB604−00−002.
2. This Service Bulletin may require consumable materials that have
specific curing times (refer to Paragraph 3). The accumulated curing
time is not included in the labor estimates and should be considered
for planning purposes before you schedule this Service Bulletin.
MODEL CL−600−2B16
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
P a g e3o f2 0

### Page 6

10 to 60 Man−Hours are necessary to do this modification.
NOTE: The estimated range of labor hours is based on the different aircraft
configurations, location of the ribbon heater installations and the possible
unexpected repairs such as heat damaged insulation.
Bombardier Aerospace does not pay for the labor to do this modification.
G. Material − Cost and Availability
No kit is necessary to do this modification.
The parts listed in Paragraph 3.B. may be necessary to do this modification.
Bombardier Aerospace does not pay for the parts to do this modification.
For all parts transactions, Bombardier Aerospace’s current Spare Parts and
Component Repair Price Catalogue General Terms and Conditions apply. These
terms and conditions are found on the Bombardier Customer Portal at:
my.businessaircraft.bombardier.com
Due to the lead−time required for obtaining kits and parts, operators are advised to
order the kits and parts in advance before scheduling the incorporation of this
Service Bulletin. Please contact Bombardier Aerospace Parts Services, in Montreal,
for delivery lead times and confirmation of prices.
Smart Parts does not pay for the parts to do this modification.
H. Tooling
The equipment and tools listed below are necessary to do this modification.
GSE REFERENCE NO. PART NO. DESCRIPTION
GSE 24−00−24 S4933959−501 Tag, Circuit Breaker
Commercially Available
ERG−4002
OR
WT−112M
OR
Thomas & Betts,
Sat−Kon Crimper
Channelock No.909 Crimping Tool
Commercially Available ERG−4002
No. 10 Torq−Set
Screwdrivers or Bits
(MS33781)
Commercially Available − Digital Multimeter
Commercially Available − Digital Thermometer
MODEL CL−600−2B16
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
P a g e4o f2 0

### Page 7

GSE REFERENCE NO. PART NO. DESCRIPTION
Commercially Available − Heat Gun
Commercially Available −
Wire Tracer or
Continuity Tester
Note: Either tracer/tester
must be equipped with a
signal transmitter
NOTES: 1. Refer to the CL −604 Illustrated Tool and Equipment Manual (ITEM),
to make sure that you use the correct equipment configuration.
2. Refer to the Introduction of the publication listed in NOTE 1 for
acceptable GSE equivalents.
3. This list is provided for a quick reference. In case of discrepancy
between this list and the tool called out in the SPM−WM, Chapter 20,
then the tool called in the SPM−WM will prevail. Other approved
alternative tools are acceptable and can also be used.
I. Weight and Balance
No change.
J. Electrical Load Data
No change.
K. References
− Bombardier Aerospace, Restriction and/or Special Instruction (RSI), C− 4228
Rev. B.
− Bombardier Aerospace, Drawing BAS63028157, Rev. C.
− Bombardier Aerospace, Drawing BAS63038360, Rev. B.
− CL−604 Aircraft Maintenance Manual, Chapters 6, 20, 24, 30, and 38.
− CL−604 Supplemental Maintenance Manual (SMM), Chapters 6, 20, 24, 30,
and 38.
− CL−604 Supplemental Illustrated Parts Catalog (SIPC), Chapter 30 and 38.
− CL−604 Illustrated Tool and Equipment Manual (ITEM), Chapter 30.
− CL−604 Supplemental Maintenance Manual (SMM), Chapters 6, 20, 24, 30,
and 38.
− Instructions for Continued Airworthiness (ICA), Document No. BAS63058024, 2
(attached).
L. Publications Affected
− Bombardier Aerospace, Supplemental Maintenance Manual (SMM), Chapter 30.
MODEL CL−600−2B16
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
P a g e5o f2 0

### Page 8

− Bombardier Aerospace, Supplemental Illustrated Parts Catalog (SIPC),
Chapter 30.
− Bombardier Aerospace, Supplemental wiring Manual (SWM), Chapter 30.
M. Equivalent Service Bulletins
− For the Challenger 601 aircraft, use SB601−0644.
2. ACCOMPLISHMENT INSTRUCTIONS
NOTES: 1. All TASKs given in the procedures that follow are from the CL −604 Aircraft
Maintenance Manual, unless otherwise specified.
2. All references made to zones, access panels and/or doors, are from
System Description Section (AMM Part One), Chapter 6.
3. If it is not possible to complete all the instructions of this Service Bulletin
because of the configuration of the aircraft, submit an SRPSA for analysis
and to get an approved disposition to complete this Service Bulletin.
E−mail: SRPSA@aero.bombardier.com
A. Aircraft Setup
NOTE: The steps in the Aircraft Setup section of this Service Bulletin are
recommended steps. The steps give a recommendation to get access to
the work area. This recommendation is to give a safe work area and to
minimize possible damage to surrounding aircraft parts. Alternative steps
can be used at the operator’s discretion.
WARNING: OBEY ALL THE SAFETY PRECAUTIONS WHEN YOU DO
MAINTENANCE ON OR NEAR ELECTRICAL/ELECTRONIC
EQUIPMENT. IF YOU DO NOT OBEY THE SAFETY
PRECAUTIONS, YOU CAN CAUSE INJURY TO PERSONS AND
DAMAGE TO THE EQUIPMENT.
(1) Obey all electrical/electronic safety precautions. Refer to
AMM 24−00−00−910−801.
(2) Remove electrical power from the aircraft.
(3) Get access to the passenger compartment area to do this Service Bulletin.
(4) Remove all interior furnishings and interior wall side panels from the Right Side
of the passenger compartment between FS335.00 and FS621.00, as required.
Refer to the aircraft specific SMM Chapter 25, if available.
(5) Remove the insulation blankets on the Right Side of the passenger
compartment between FS335.00 and FS621.00 as required, refer to
AMM 25−80−01−000−801.
(6) Remove the cargo compartment floor −panels 242ERF and 242FRF. Refer to
AMM 53−01−01−000−803.
MODEL CL−600−2B16
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
P a g e6o f2 0

### Page 9

B. PART A − Inspection of Ribbon Heater Installation and Insulation (Mandatory)
(1) This modification is applicable to aircraft that have the COX & CO. 3043 Series
ribbon heaters installed through one of the following drawings:
NOTES: 1. If water lines are not equipped with COX & CO. 3043 Series
Ribbon heater, no further action is required. Proceed to the
Close−Out.
− Bombardier Drawing TM453071−XX “W/D EL Water Heaters”.
− Innotech Aviation Drawing WDBXXXX−XXX “W/D − Water Heaters, Galley
and Vanity”.
− Bombardier Drawing 6043070004 ”W/D − Water Line Heater System”.
− Bombardier Drawing 6043070005 “W/D − Water Line Heater System −
Small Lavatory”.
− Bombardier Drawing BAS6302XXXX “W/D Water Heater Modification”.
− Bombardier Drawing BAS6302XXXX “W/D − Ribbon Heater Installation
Modification”.
(2) Visually inspect the water −line ribbon heater installation and insulation per
Drawing BAS63028157:
(a) Inspect the insulation wrapped around the ribbon heater for any
discoloration, blistering or cracking of insulation. If any of these or other
signs of wear or heat damage are present, proceed to PART B. If no signs
of wear or damage are present, proceed to PART E.
NOTE: Since there are various aircraft configurations, make sure all
ribbon heater locations are verified as per the aircraft specific
Engineering.
C. PART B − Removal of Ribbon Heater Insulation (If necessary)
(1) Do the following steps only if the ribbon heater insulation was found damaged
per PART A.
(a) Remove securing tape then remove insulation per NOTE 17 of Drawing
BAS63028157.
(b) Proceed to PART C to replace the ribbon heater.
D. PART C − Replacement of Ribbon Heater (If necessary)
(1) Do the following steps if the ribbon heater insulation was removed per PART B.
(a) Disconnect ribbon heater pigtail wiring.
(b) Remove securing tape.
CAUTION: USE EXTREME CARE NOT TO DAMAGE THE WATER LINE
WHEN YOU REMOVE THE RIBBON HEATER.
(c) Remove ribbon heater per NOTE 17 of Drawing BAS63028157.
MODEL CL−600−2B16
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
P a g e7o f2 0

### Page 10

(d) Install new ribbon heater per NOTE 17 of Drawing BAS63028157.
(e) Proceed to PART D.
E. PART D − Installation of New Ribbon Heater Insulation (If necessary)
(1) Do the following steps only if the ribbon heater insulation was found damaged
per PART A.
(a) Install new ribbon heater insulation per NOTE 17 of Drawing
BAS63028157 and per Drawing BAS63038360.
F. PART E − Addition of Ribbon Heater Pigtail Wire Identification (Mandatory)
(1) Make sure that the ribbon heater pigtail wires are disconnected from all other
aircraft wiring.
(2) The ribbon heater has a wiring pigtail containing two wires. Inspect the
individual wires within the pigtail, and do as follows:
(a) Using a signal or wire tracer or continuity tester, all equipped with a signal
transmitter, determine which of the two ribbon heater wires is the return
lead per NOTE 12 of Drawing BAS63028157.
NOTE: Make sure that the ribbon heater pigtail wires are disconnected
from all other aircraft wiring.
(b) Install a white shrinkable tube on the power lead on the ribbon heater.
Make sure no black marking is seen on the lead determined to be the
power lead.
(c) Install black heat shrinkable tube on the return lead of the ribbon heater.
The resulting pigtail configuration should consist of one white wire (the
power lead) and one black wire (the return lead).
(d) Proceed to PART F.
G. PART F − Fuse Installation (Mandatory)
(1) Assemble the fuse holders per instructions in Figure 1.
(2) Connect a fuse holder to the ribbon heater power lead (white wire) and install a
fuse per NOTE 9 and 14 of Drawing BAS63028157.
(3) Make sure that the ribbon heater pigtail wires are connected to all aircraft
wiring per NOTE 9 of Drawing BAS63028157.
(4) Make sure you do Part A to Part F for each existing ribbon heater.
(5) Proceed to PART G only when all ribbon heaters have been verified.
H. PART G − Testing (Mandatory)
(1) If the water line was removed, do an operational test of the potable water
system per applicable aircraft specific SMM 38−10−00.
(2) If the SMM is not available, make sure there are no leaks as per best shop
practices.
MODEL CL−600−2B16
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
P a g e8o f2 0

### Page 11

(3) Do an operational test of the water line heater system per applicable aircraft
specific SMM 38−10−00.
(4) If the SMM is not available, test the water line heater system in the steps that
follow per best shop practice:
(a) Press the AC/DC UTILITY switch. (Location of switch may vary on each
aircraft).
(b) Using a digital thermometer probe, touch a point on each ribbon heater
and note the measured temperature.
(c) Locate the thermostat on each ribbon heater, apply a coat of cooling agent
(freeze spray) to lower the temperature. Make sure the temperature is
below 40°F (4.4°C).
(d) The water line should warm up in a few minutes. Using a digital
thermometer probe touch the same point on each ribbon heater and note
that the measured temperature is higher than that measured in step (b).
CAUTION: MAKE SURE YOU DO NOT APPLY A TEMPERATURE MORE
THAN 122° F (50.0° C). YOU MAY CAUSE DAMAGE TO THE
EQUIPMENT.
(e) Apply heat to the thermostat on each ribbon heater and make sure that the
applied temperature is above 60°F (15.6°C).
(f) Remove the heat source.
(g) After a few minutes, using a digital thermometer probe, touch the same
point on each ribbon heater and note that the measured temperature is
lower than that taken in step (d).
(5) Make sure you repeat all applicable steps for each ribbon heater.
I. Close −Out
NOTE: The steps in the Close −out section of this Service Bulletin, except for the
return−to−service tests, are recommended steps. The steps give a
recommendation to install components removed during the Aircraft
Set−Up. This recommendation is to make sure that the aircraft is safe and
ready to return to service. Alternative steps can be used at the operator’s
discretion.
(1) Install the cargo compartment floor −panels 242ERF and 242FRF. Refer to
AMM 53−01−01−400−803.
(2) Install the insulation blankets on the Right Side of the passenger compartment
between FS335.00 and FS621.00 as required per AMM 25−80−01−400−801.
(3) Install all interior wall side panels and interior furnishings on the Right Side of
the passenger compartment between FS335.00 and FS621.00, as required.
Refer to the aircraft specific SMM Chapter 25, if available.
(4) Remove all tools, equipment and unwanted materials from the work area.
MODEL CL−600−2B16
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
P a g e9o f2 0

### Page 12

J. Recording
When this Service Bulletin is completed, make an entry in the aircraft log and send
the attached Incorporation Notice to Bombardier Business Aircraft Customer
Services (BBACS).
In an effort to improve the quality of our technical communications, we are
requesting your feedback. Please take a moment to fill out our easy on−line Service
Bulletin survey:
http://csefeedback.aero.bombardier.com
3. MATERIAL INFORMATION
A. Kit
No Kit is necessary to do this modification.
B. Parts
The parts that follow may be necessary to do this Service Bulletin and are available
from Bombardier Aerospace Parts Services, Montreal:
NEW PART NO. QTY ITEM USED PARTNO. INSTRUCTIONS-DISPOSITION
3043−5T A/R Heater, RibbonCOX & CO. − −
3043−6T A/R Heater, RibbonCOX & CO. − −
3043−7T A/R Heater, RibbonCOX & CO. − −
3043−8T A/R Heater, RibbonCOX & CO. − −
3043−11T A/R Heater, RibbonCOX & CO. − −
3043−13T A/R Heater, RibbonCOX & CO. − −
3043−15T A/R Heater, RibbonCOX & CO. − −
3043−16T A/R Heater, RibbonCOX & CO. − −
MODEL CL−600−2B16
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
Page 10 of 20

### Page 13

NEW PART NO. QTY ITEM USED PARTNO. INSTRUCTIONS-DISPOSITION
3043−18T A/R Heater, RibbonCOX & CO. − −
3043−19T A/R Heater, RibbonCOX & CO. − −
3043−20T A/R Heater, RibbonCOX & CO. − −
3043−23T A/R Heater, RibbonCOX & CO. − −
AGC−1/2−R A/R Fuse, In−Line,0.5 AMP − −
AGC−3/4−R A/R Fuse, In−Line,0.75 AMP − −
AGC−1−R A/R Fuse, In−Line,1.0 AMP − −
AGC−1−1/2−R A/R Fuse, In−Line,1.5 AMP − −
AGC−2−R A/R Fuse, In−Line,2.0 AMP − −
AGC−2−1/4−R A/R Fuse, In−Line,2.25 AMP − −
AGC−3−R A/R Fuse, In−Line,3.0 AMP − −
AGC−5−R A/R Fuse, In−Line,5.0 AMP − −
N331−3827 A/R
Insulation
(MICROLITE
AA−WRP)
Or Alternate
MMS 03−001,
Type 1, Class
AA, Grade D,
Group 3
− −
MODEL CL−600−2B16
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
Page 11 of 20

### Page 14

NEW PART NO. QTY ITEM USED PARTNO. INSTRUCTIONS-DISPOSITION
N389−9202 A/R
Film
(LAMAGUARD
12)
Or Alternate
MMS 02−001,
Type 3
− −
HFA−R A/R Fuse Holder,In−Line − −
M23053/5−104−9 A/R Heat Shrink Tube − −
M23053/5−105−9 A/R Heat Shrink Tube − −
M23053/
13−001−0 A/R Heat Shrink Tube − −
MIL−W−22759/
34−16−9
OR
MIL−W−22759/
43−16−9
OR
B0801250−16−9
100
inches
per
aircraft
Single Type Wire
16AWG
− −
NOTE: The part numbers for the items listed above are subject to change without
revision to this Service Bulletin. In case of discrepancy between this list
and any other list, the Illustrated Parts Catalog prevails and shall be used
to determine the latest part number.
C. Material
The materials that follow, or equivalent, are necessary to do this Service Bulletin.
These can be purchased from a local supplier. Bombardier Aerospace does not pay
for these consumables.
DESCRIPTION PARTNO./NAME SPECIFICATION QUANTITY SUPPLIER
Tape, Glass Cloth
0.5 in wide − MIL−I−19166 As Necessary CommerciallyAvailable
Tape, 1.50 in wide,
LT−16
Or use Alternate:
Tape, 1.50 in wide
− LamartCorporation As Necessary CommerciallyAvailable
− MMS 01−001,TYPE 6 As Necessary CommerciallyAvailable
MODEL CL−600−2B16
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
Page 12 of 20

### Page 15

DESCRIPTION PARTNO./NAME SPECIFICATION QUANTITY SUPPLIER
Freeze Spray − − As Necessary CommerciallyAvailable
NOTES: 1. The Curing Time (CT), if applicable, for each consumable material is
indicated with the description of each product.
2. At time of release of this Service Bulletin, the information on the
supplier was valid and accurate. In the event that this information has
changed, the operator is encouraged to use the World Wide Web to
find a local supplier.
D. Publications
No publications required.
MODEL CL−600−2B16
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
Page 13 of 20

### Page 16

LSB3008_001
CRIMP TERMINAL CRIMP TERMINAL
WIRE
CRIMP
WIRE
HEATSHRINK TUBE
P/N: M23053/5 −104 −9
(1.5 in LENGTH)
HEATSHRINK TUBE
P/N: M23053/5 −105 −9
(1.0 in LENGTH)
HEATSHRINK TUBE
P/N: M23053/13 −001 −0
(1.0 in LENGTH)
1) Strip the wire of equal length as the crimp terminal.
2) Insert the wire into the crimp terminal of the fuse holder.
3) Crimp the assembly with the crimping tool.
4) Repeat on the opposite end of the fuse holder.
5) Insert the heat shrink tube (1.5 in Length),
    P/N: M23053/5 −104 −9 at both ends of the fuse holder.
6) Apply heat to the heatshrink tubes.
7) Insert the heat shrink tube (1.0 in Length),
    P/N: M23053/5 −105 −9 at both ends of the fuse holder.
8) Apply heat to the heatshrink tubes.
9) Insert the heat shrink tube (1.0 in Length),
    P/N: M23053/13 −001 −0 at both ends of the fuse holder.
10) Apply heat to the heatshrink tubes.
11) Fuse holder ready for installation.
MODEL CL−600−2B16
Fuse Holder Assembly
Figure 1
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
Page 14 of 20

### Page 17

SB604−30−007_001
BAS63028157 − WD − WATER SYSTEM POTABLE WATER LINE RIBBON HEATER
MODIFICATION
(Sheet 1 of 4, Rev. C)
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
Page 15 of 20

### Page 18

SB604−30−007_002
BAS63028157 − WD − WATER SYSTEM POTABLE WATER LINE RIBBON HEATER
MODIFICATION
(Sheet 2 of 4, Rev. C)
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
Page 16 of 20

### Page 19

SB604−30−007_003
BAS63028157 − WD − WATER SYSTEM POTABLE WATER LINE RIBBON HEATER
MODIFICATION
(Sheet 3 of 4, Rev. C)
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
Page 17 of 20

### Page 20

SB604−30−007_004
BAS63028157 − WD − WATER SYSTEM POTABLE WATER LINE RIBBON HEATER
MODIFICATION
(Sheet 4 of 4, Rev. C)
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
Page 18 of 20

### Page 21

SB604−30−007_005
BAS63038360 − POTABLE WATER SYSTEM MOIFICATION − INSULATION
REPLACEMENT
(Sheet 1 of 2, Rev. B)
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
Page 19 of 20

### Page 22

SB604−30−007_006
BAS63038360 − POTABLE WATER SYSTEM MODIFICATION − INSULATION
REPLACEMENT
(Sheet 2 of 2, Rev. B)
Basic Issue: Mar 27/2018
Revision 01: Jan 29/2019
604−30−007
Page 20 of 20

### Page 23

604−30−007 Rev. 01 Jan 29/2019
SPECIAL CHECK/MODIFICATION − POTABLE WATER SYSTEM/WATER
LINE HEATERS − WATER LINE RIBBON HEATERS WIRING
In an effort to improve the quality of our technical communications, we are replacing the
standard Service Bulletin Evaluation Form with an on−line Service Bulletin Survey
and we are requesting your feedback. Please take a moment to fill out our easy on−line
Service Bulletin survey at:
http://csefeedback.aero.bombardier.com
SERVICE BULLETIN EVALUATION FORM
(Your ideas will help us provide better bulletins)
SERVICE BULLETIN: ISSUE: DATED:
TITLE:

### Page 24

SERVICE BULLETIN INCORPORATION SHEET − "604−30−007"
Upon completion of the Service Bulletin, please fill−in, fax to
(514) 855−8798 or e−mail to Fracas at fracas.montreal@aero.bombardier.com
If you’re reporting Service Bulletin (SB) Incorporations to CAMP, sending
this Incorporation Sheet to Bombardier is not mandatory. If your aircraft is
on another tracking system, please contact Bombardier to make arrangements
for automated data submission.
604−30−007 01
COMPLIED WITH
YES    NO    N/A
Actual hours to accomplish Service Bulletin:
* NOTES:
Aircraft Serial No. Aircraft Reg. No.
Airframe Hours: Airframe Landings
S.B. Incorporation Date Service Order No.
Facility incorporating S.B.
Name Signature Date
BOMBARDIER
SUBMISSION
Service Bulletin
Number
Rev. * Parts
Completed
Remarks/Reason
(Mandatory if N/A)
1. Where the Service Bulletin is divided into a number of parts (e.g., PARTS A,
B, C, D, etc.) which can be carried out separately, indicate only those parts
completed at this time.
2. For repetitive checks (usually PART A) only the initial check should be
reported unless otherwise stated in the Service Bulletin.
3. When more than one part is carried out at the same time, each part should
be reported.
4. Fill in ’Remark/Reason’ to explain compliance method when N/A is selected.(E.g. Part
not installed, N/A by effectivity, N/A by Part Serial Number, etc.
5. PCW means ’Previously Complied With’.
(dd/mm/yy)
Signature not required if sent by E−Mail (dd/mm/yy)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.
