# Bombardier Service Bulletin 605-24-005

Copy: No revision named ("U.S. DOT/FAA - Service Information - 1"), 12 pages: PDF https://openairdocs.org/files/sha256/3b/b4/3bb4aa5281279513289155a2cf41f8fcb6c65de282c8cf3781be1a4689da3bf0; text https://openairdocs.org/service-documents/bombardier/sb-605-24-005/file/3bb4aa528127.md. Rights: © Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2012-0146; AD 2012-21-11 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Bombardier](https://openairdocs.org/service-documents/bombardier.md)
- Type: Service bulletin (Service Bulletin)
- Number: 605-24-005
- Page: https://openairdocs.org/service-documents/bombardier/sb-605-24-005

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2012-21-11](https://openairdocs.org/ad/2012-21-11.md), effective Dec 4, 2012: No revision named

## Text (12 pages)

Rights: © Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2012-0146; AD 2012-21-11 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

Basic Issue: Jan 31/2011 605-24-005 
  Page 1 of 1 
SERVICE BULLETIN SUMMARY This Service Bulletin is available at: 
www.cic.bombardier.com 
MODEL CL-600-2B16 
ATA 24-00 
ELECTRICAL POWER 
MODIFICATION – OXYGEN SUPPLY SYSTEM –  
INSTALLATION OF PROTECTION ON ELECTRICAL WIRING HARNESS 
The information below is provided for your reference.  For full details, please 
see corresponding paragraph contained within this bulletin. 
RECOMMENDED SPECIFIED TIME COMPLIANCE COMPLIANCE TIME Within 800 flight hours from the  release date of this Service Bulletin 
EFFECTIVITY: A/C Serial No. 5701 to 5778, 5780 to 5796, 5798, 5800 to 5802, 5804, 
5805, 5808, 5811 and 5813 
MANPOWER: 2 man-hours 
TLMC, CH 5, PART 4 REQUIREMENT YES  NO  
KITS and/or PARTS YES  NO  
TOOLING/GSE YES  NO  
PLANNING INFORMATION:  See important 
information at the start of Paragraph 1. YES  NO  
DEDICATED SCHEDULE YES  NO  
PREREQUISITE SERVICE BULLETINS: N/A 
NOTE: For convenience, it is recommended to do SB 605-35-001 at the same time as this 
Service Bulletin. 
To place an order for parts or kits, please call Bombardier Parts Logistics at: 
514-855-2999 or 1-866-538-1247

### Page 2

Refer to applicable governmental agency regulations and requirements and make sure that the work described in this 
Service Bulletin is performed in compliance with manufacturer’s recommendations and/or acceptable industry 
standards. 
This document is proprietary to Bombardier Inc. and/or its affiliates and may not be reproduced or copied in any form or 
by any means without the prior written consent of Bombardier Inc. and/or its affiliates. 
© 2011 Bombardier Inc.  All rights reserved 
Challenger*, Global Express*, Global Express XRS*, Global 5000*, Learjet* are Trademarks of Bombardier Inc. 
Basic Issue: Jan 31/2011 605-24-005 
  Page 1 of 7 
SERVICE BULLETIN This Service Bulletin is available at: 
www.cic.bombardier.com 
MODEL CL-600-2B16 
ATA 24-00 
ELECTRICAL POWER 
MODIFICATION – OXYGEN SUPPLY SYSTEM –  
INSTALLATION OF PROTECTION ON ELECTRICAL WIRING HARNESS 
 
1. PLANNING INFORMATION 
NOTE: For convenience, it is recommended to do SB 605-35-001 at the same time as  
this Service Bulletin. 
A. Effectivity 
CL-600-2B16 aircraft, Serial No. 5701 to 5778, 5780 to 5796, 5798, 5800 to 5802,  
5804, 5805, 5808, 5811 and 5813. 
All other CL-600-2B16 aircraft, already meet the intent of this Service Bulletin, 
(Ref.: Restriction and/or Special Instruction (RSI), C-4067). 
NOTE: The instructions given in this Service Bulletin are only applicable to the  
systems and parts installed at the time of delivery of the aircraft or as  
changed by Bombardier Aerospace Service Bulletin(s).  
Before you do this bulletin, examine all STC, STA or equivalent action  
changes to make sure that this bulletin can be completed. 
B. Reason 
The electrical harness going to the oxygen pressure transducer (MT1WQ) and 
to the low pressure switch (S1WQ) has been installed without protection in the 
area of the oxygen cylinder.  The wiring could chafe against the oxygen system 
components or surrounding structure in the area.  This Service Bulletin adds 
protective conduit sleeving to eliminate any chafing conditions.

### Page 3

MODEL CL-600-2B16 
Basic Issue: Jan 31/2011 605-24-005 
  Page 2 of 7 
C. Description 
This Service Bulletin gives instructions to: 
– Access the oxygen cylinders behind the wardrobe, 
– Inspect and add protective conduit sleeving on affected wiring , and 
– Do the necessary test to make sure the system operates correctly. 
D. Compliance 
Recommended within 800 flight hours from this Service Bulletin release date  
(Basic Issue). 
E. Approval 
The technical content of this Service Bulletin has been approved under the  
authority of Transport Canada Civil Aviation (TCCA) Design Approval 
Organization (DAO) No. DAO #93-Q-02. 
NOTES: 1. The technical content of this Service Bulletin is accepted by the  
FAA under the Canada/USA bilateral Aviation Safety Agreement. 
2. The technical content of this Service Bulletin is accepted by the  
JAA and by EASA in accordance with established procedures. 
F. Manpower 
NOTES: 1. The man-hours given are estimates to help you schedule the tasks  
given in this bulletin.  The estimates are for direct labor performed 
by an experienced crew and do not include the time for 
familiarization, planning, aircraft preparation in hangar such as 
towing and positioning of scaffolds, removal of interior furnishings, 
repainting, supervision and inspection.  
For more information related to the manpower estimates, refer to  
SB 605-00-002. 
2. This Service Bulletin may require consumable materials that have 
specific curing times (refer to Paragraph 3).  The accumulated 
curing time is not included in the labor estimates and should be 
considered for planning purposes before you schedule this Service 
Bulletin. 
2 man-hours are necessary to inspect and do the modification. 
The labor required to do this Service Bulletin is at no cost if: 
(i) the work is done at Bombardier Business Aviation Services (BBAS)  
or Authorized Service Facilities (ASF), and 
(ii) this Service Bulletin is scheduled in less than 48 months from its 
release date (Basic Issue).

### Page 4

MODEL CL-600-2B16 
Basic Issue: Jan 31/2011 605-24-005 
  Page 3 of 7 
G. Material - Cost and Availability 
No kit or parts are necessary to do this modification.  For material data, refer to 
Paragraph 3. 
H. Tooling 
GSE REFERENCE NO. PART NO. DESCRIPTION 
GSE 24í00í24 - Tag, Circuit Breaker 
NOTE: Refer to the CL-605 Illustrated Tool and Equipment Manual to make sure  
that you use the correct equipment configuration. 
I. Weight and Balance 
No change. 
J. Electrical Load Data 
No change. 
K. References 
– Bombardier Aerospace, Restriction and/or Special Instruction (RSI),  
C-4067, Rev. NC. 
– Bombardier Aerospace, SB 605-35-001 “Special Check/Modification – 
Oxygen Supply System – Inspection and Replacement of Oxygen Cylinder 
and Regulator Assembly (CRA) with Specific Serial Numbers”. 
– CL-605 Aircraft Maintenance Manual (AMM), Chapters 6, 12 and 35. 
– CL-605 Standard Practice Manual (SPM), Chapter 20. 
L. Other Publications Affected 
None. 
M. Equivalent Service Bulletin 
None.

### Page 5

MODEL CL-600-2B16 
Basic Issue: Jan 31/2011 605-24-005 
  Page 4 of 7 
2. ACCOMPLISHMENT INSTRUCTIONS 
NOTES: 1. All TASKs given in the procedures that follow are from the CL-605 
Aircraft Maintenance Manual unless otherwise specified. 
2. All references made to zones, access panels and/or doors, are from  
the CL-605 Aircraft Maintenance Manual, Chapter 6. 
A. Aircraft Setup 
WARNING: OBEY ALL THE SAFETY PRECAUTIONS WHEN YOU DO 
MAINTENANCE ON OR NEAR ELECTRICAL/ELECTRONIC 
EQUIPMENT. IF YOU DO NOT DO THIS, YOU CAN CAUSE 
INJURIES TO PERSONS AND/OR DAMAGE TO THE 
EQUIPMENT 
(1) Make sure that the aircraft is in the standard configuration for maintenance.  
Refer to TASK 12-00-00-867-801. 
(2) Obey all the oxygen system safety precautions.  Refer to  
TASK 35-00-00-910-801. 
(3) Open and tag the circuit breaker that follows: 
CB PANEL CB NO. NAME ZONE 
CBP 2 P9 PASS/CREW OXYGEN 222 
(4) Gain access to the oxygen cylinder through the wardrobe.

### Page 6

MODEL CL-600-2B16 
Basic Issue: Jan 31/2011 605-24-005 
  Page 5 of 7 
B. Modification – Wiring Protection Addition 
(1) Behind the wardrobe, in the area of the crew oxygen reservoir, inspect  
the electrical wiring connected to the following connector, P1WQ and 
surrounding components for signs of damaged insulation, abrasion, or 
chaffing.  The following wires require inspection:  (Ref. Refer to the Wiring  
Manual, Chapter 35-21-00).  See Photo 1. 
(a) Oxygen Pressure Transducer MT1WQ with connector P1WQ,  
(consisting of 2 single wire conductors, 1 twisted-shielded pair,  
and 1 shield return wire (respectively): WQ1G24, WQ10A20N,  
WQ2A24WHT, WQ3A24BLU and WQ4A20N (wire for shield  
return to ground)). 
(b) Low Pressure Switch S1WQ with connector P5WQ, (consisting  
of 2 wires: WQ22C24 and WQ19A20N). 
 
        Photo 1 
(2) Make sure that the harness is not coiled, and that there is no excessive 
slack, ensuring a minimum clearance distance of 0.5 inch even with 
harness movement, per Standard Practices Manual, Section 20-12-00  
“Wiring – Maintenance Practices”.   
(3) If necessary, trim wiring to length or push any excessive slack back into  
the main harness, while maintaining a drip loop (with connectors mated),  
per Standard Practices Manual, Section 20-12-00 “Wiring – Maintenance 
Practices”. 
(4) Install a wrap-around protective conduit sleeving, Part No. S8021-2  
(or other equivalent) over the harness and spot tie with lacing tape, per 
Standard Practices Manual, Section 20-12-00 “Wiring – Maintenance 
Practices”.  See Photo 2.

### Page 7

MODEL CL-600-2B16 
Basic Issue: Jan 31/2011 605-24-005 
  Page 6 of 7 
 
Photo 2 
C. Testing 
(1) Remove the tag and close the circuit breaker that follows: 
CB PANEL CB NO. NAME ZONE 
CBP 2 P9 PASS/CREW OXYGEN 222 
(2) If connector P1WQ has been disconnected from the Oxygen Pressure 
Transducer MT1WQ, perform an operational test.  Refer to  
TASK 35-12-04-710-801. 
(3) If connector P5WQ has been disconnected from the Oxygen Low Pressure 
Switch S1WQ, make sure connector P5WQ is fully mated onto its mating 
receptacle.  There is no retest procedure required. 
D. Close-out 
(1) Remove all tools, equipment and unwanted materials from the aircraft. 
(2) Close the access to the oxygen cylinder in the wardrobe. 
E. Recording 
When this Service Bulletin is completed, make an entry in the aircraft log and 
send the attached Incorporation Notice to Bombardier Business Aircraft 
Customer Services (BBACS).

### Page 8

MODEL CL-600-2B16 
Basic Issue: Jan 31/2011 605-24-005 
  Page 7 of 7 
3. MATERIAL INFORMATION 
A. Kit 
No kits required. 
B. Parts 
No parts are required. 
C. Material 
The materials that follow, or equivalent, are necessary to do this Service Bulletin.   
These can be purchased from a local supplier.  Bombardier Aerospace does not  
pay for these consumables. 
DESCRIPTION PART 
No./NAME 
SPECIFICATION QUANTITY SUPPLIER  
(See Note) 
Lacing cord - - As 
Necessary 
Code: A 
Protective 
Sleeving 
S8021-2 - 4 feet Code: B 
Lockwire  - MS20995CY20 As 
Necessary 
Code: C 
NOTES: 1. Refer to the table that follows for each supplier’s address listed by codes. 
2. The Curing Time (CT), if applicable, for each consumable material 
is indicated with the description of each product. 
3. At time of release of this Service Bulletin, the information on the 
supplier was valid and accurate.  In the event that this information 
has changed, the operator is encouraged to use the World Wide 
Web to find a local supplier. 
SUPPLIERS ADDRESSES BY CODES 
Code: A 
Varflex. 
512 W. Court Street 
Rome, NY USA 13440  
Phone: 315-336-4400  
Fax: 315-336-0005 
www.varflex.com 
Code: B 
Tyco Electronics Corpora 
1050 Westlakes Drive 
Berwyn, PA 19312 
Phone: 610-893-9800 
www.tycoelectronics.com 
Code: C 
Commercially Available 
D. Publications 
No publications required.

### Page 9

THANK YOU FOR YOUR RESPONSE! 
PLEASE RETURN THIS COMPLETED EVALUATION FORM BY MAIL, E-MAIL OR FAX 
SERVICE BULLETIN EVALUATION FORM 
(Your ideas will help us provide better bulletins) 
SERVICE BULLETIN: 605-24-005 ISSUE: Basic DATED: Jan 31/2011 
      
TITLE: Modification – Oxygen Supply System – Installation of Protection on Electrical Wiring 
Harness 
 STRONGLY 
DISAGREE 
DISAGREE AGREE STRONGLY 
AGREE 
N/A 
x Instructions to do the Service Bulletin  
were accurate. 
 Comments: 
     
x Illustration(s), figure(s), and/or kit drawing(s) 
were helpful to carry out instructions. 
 Comments: 
     
x If a kit and/or parts were required, did the 
contents of the kit and/or parts received agree 
with the contents listed in the bulletin? 
 Comments: 
     
x The consumable materials listed under 
Paragraph 3 were easily procured. 
 Comments:  
     
x Work was accomplished in the prescribed time. 
Comments      
x Overall, I was satisfied with this Service Bulletin. 
 Comments:       
For 
administrative 
use only 
PLEASE SUPPLY US WITH THE FOLLOWING DATA AND FAX TO: (514) 855-7634  
or  
E-MAIL TO: MTL_BBAD_SB_Evaluation@aero.bombardier.com 
 OPERATOR:  
051TC AIRCRAFT SERIAL NO.:  
 TELEPHONE:  
 FACSIMILE:  
 NAME: (Please print)

### Page 10

-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 
 
 
 
 
 
Bombardier Business Aircraft Customer Services (BBACS) 
P.O. Box 6087, Station Centre-ville 
Montréal, Québec, Canada H3C 3G9 
 
Attention: Customer Support Department 
 
 
 
 
 
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --

### Page 11

SERVICE BULLETIN INCORPORATION SHEET – “605-24-005” 
 
BOMBARDIER 
SUBMISSION Upon completion of the Service Bulletin, please fill-in, fax to 
(514) 855-8798 or e-mail to Fracas at fracas.montreal@aero.bombardier.com 
 
If your aircraft is registered on CAMP and you are reporting to them, 
please do not send the incorporation sheet to Bombardier. If your aircraft 
is on another tracking system, please contact Bombardier to make 
arrangements for automated data submission. 
 
 
           COMPLIED WITH  
 Service Bulletin 
Number 
 Rev.  * Parts 
Completed 
 YES NO N/A Remarks/Reason 
 605-24-005  Basic  -       
 -  -  -       
 -  -  -       
 
 Actual hours to accomplish Service Bulletin:    
 
1. Where the Service Bulletin is divided into a number of parts (e.g., PARTS A, 
B, C, D, etc.) which can be carried out separately, indicate only those parts 
completed at this time. 
2. For repetitive checks (usually PART A) only the initial check should be 
reported unless otherwise stated in the Service Bulletin. 
* NOTES:  
 
 
  
  3. When more than one part is carried out at the same time, each part should be 
reported. 
 
 Aircraft Serial No.   Aircraft Reg. No.   
 Airframe Hours:   Airframe Landings   
 S.B. Incorporation date   Service Order No.   
  (dd/mm/yy)    
 Facility Incorporating S.B.  
 Name  Signature  Date  
                               (dd/mm/yy) Signature not required if sent by E-Mail

### Page 12

-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --  
 
 
 
 
 
Bombardier Business Aircraft Customer Services (BBACS) 
P.O. Box 6087, Station Centre-ville 
Montréal, Québec, Canada H3C 3G9 
 
Attention: Customer Support Department, Maintenance Engineering 
 
 
 
 
 
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.