# Bombardier Service Bulletin 700-35-7502

Copy: No revision named ("700-35-7502 Basic"), 15 pages: PDF https://openairdocs.org/files/sha256/bd/66/bd6683006aa43343bc12d01caa52d9d5caa0dedecb6645fef98867466300a0e2; text https://openairdocs.org/service-documents/bombardier/sb-700-35-7502/file/bd6683006aa4.md. Rights: © Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2022-1065; AD 2022-23-04 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Bombardier](https://openairdocs.org/service-documents/bombardier.md)
- Type: Service bulletin (Service Bulletin)
- Number: 700-35-7502
- Page: https://openairdocs.org/service-documents/bombardier/sb-700-35-7502

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2022-23-04](https://openairdocs.org/ad/2022-23-04.md), effective Dec 30, 2022: No revision named

Also cited in [1 proposed AD](https://openairdocs.org/service-documents/bombardier/sb-700-35-7502/proposed.md).

## Text (15 pages)

Rights: © Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2022-1065; AD 2022-23-04 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

MODIFICATION – GENERAL –
REPLACEMENT OF THE OXYGEN CYLINDER AND REGULATOR ASSEMBLY
The information below is provided for your reference. For full details, including labor and part
coverage, please see corresponding paragraph contained within this bulletin.
RECOMMENDED
SPECIFIED TIME COMPLIANCE
COMPLIANCE TIME
Within 36 months from this Service Bulletin
release date (Basic Issue)
EFFECTIVITY:
BD−700−2A12 aircraft, Serial No. 70006, 70008, 70009 to 70016, 70019,
70020, 70025, 70026, 70028, 70032 to 70035, 70038 to 70043, 70046,
70048, 70050, 70051, 70054, 70063, and 70073.
MANPOWER: 5 man−hours
CONTINUED AIRWORTHINESS (CAW)
FLEET CAMPAIGN YES NO
AIRWORTHINESS LIMITATIONS (AWL) NOYES
KITS and/or PARTS YES NO
TOOLING/GSE YES NO
PLANNING INFORMATION: See important
information at the start of Paragraph 1. YES NO
DEDICATED SCHEDULE YES NO
PREREQUISITE SERVICE BULLETINS: NA
To place an order for parts, please call Bombardier Aviation Parts Services at:
514−855−2999 or 1−866−538−1247
SERVICE BULLETIN SUMMARY
my.businessaircraft.bombardier.com
MODEL BD−700−2A12 (BD−700)
ATA 35−00
OXYGEN
Basic Issue: Jan 26/2022 700−35−7502
Page 1 of 1
This Service Bulletin is available at:

### Page 2

MODIFICATION – GENERAL –
REPLACEMENT OF THE OXYGEN CYLINDER AND REGULATOR ASSEMBLY
1. PLANNING INFORMATION
NOTES:1 . Before you do this Service Bulletin, examine all STC, STA or
equivalent action changes to make sure that this Service Bulletin can
be completed.
2. This Service Bulletin is covered by a dedicated schedule. Dedicated
schedules are used to reserve and manage inventory due to limited
availability of rotable stock, parts and/or kits. Parts are limited, therefore,
advance part scheduling with our In−Service Implementation Team (ISIT)
is recommended prior to a maintenance visit. They can be reached at
bacs_isit@aero.bombardier.com. The parts will be allocated on a first
come first serve basis.
Should you require additional information, please contact your Regional
Sales Manager (RM) or Field Service Representative (FSR).
For more information on dedicated schedules, refer to SB 700−00−7502.
A. Effectivity
BD−700−2A12 aircraft, Serial No. 70006, 70008, 70009 to 70016, 70019, 70020,
70025, 70026, 70028, 70032 to 70035, 70038 to 70043, 70046, 70048, 70050,
70051, 70054, 70063, and 70073.
NOTE: The instructions given in this Service Bulletin are only applicable to the
systems and parts installed at the time of delivery of the aircraft or as
changed by Bombardier Aviation Service Bulletin(s).
SERVICE BULLETIN
my.businessaircraft.bombardier.com
MODEL BD−700−2A12 (BD−700)
ATA 35−00
OXYGEN
Refer to applicable governmental agency regulations and requirements and make sure that the work described in this
Service Bulletin is performed in compliance with manufacturer’s recommendations and/or acceptable industry standards.
This document is proprietary to Bombardier Inc. and/or its affiliates and may not be reproduced or copied in any form or
by any means without the prior written consent of Bombardier Inc. and/or its affiliates.
 2022 Bombardier Inc.  All rights reserved
Learjet, Challenger, Global, are registered trademarks of Bombardier Inc. or its subsidiaries.
Basic Issue: Jan 26/2022 700−35−7502
Page 1 of 12
This Service Bulletin is available at:

### Page 3

TABLE 1 – SERIAL NUMBERS OF AFFECTED OXYGEN
CYLINDERS
EFFECTIVITY SERIAL NUMBERS
70006
C18070053
C18070054
70008
C20020079
C20030812
70009
C18040616
C18040103
70010
C19030319
C19030324
70011
C18060113
C18060114
70012 C18090917
70013
C19061309
C19060445
70014 C19030326
70015
C18080109
C18050820
70016
C18050819
C18060181
70019
C18050200
C18050201
70020
C19070298
C19030462
70025 C18040836
MODEL BD−700−2A12 (BD−700)
Basic Issue: Jan 26/2022 700−35−7502
Page 2 of 12

### Page 4

TABLE 1 – SERIAL NUMBERS OF AFFECTED OXYGEN
CYLINDERS
EFFECTIVITY SERIAL NUMBERS
70026
C18050891
C18050890
70028
C18070785
C18070768
70032
C19030320
C18040102
70033
C17010404
C18010904
70034
C19110502
C19110495
70035
C18090621
C18010179
70038
C18070769
C18070770
70039
C19030460
C20020083
70040
C19110182
C19110499
70041 C19060446
70042 C19110184
70043
C20030815
C20030817
70046 C19050811
MODEL BD−700−2A12 (BD−700)
Basic Issue: Jan 26/2022 700−35−7502
Page 3 of 12

### Page 5

TABLE 1 – SERIAL NUMBERS OF AFFECTED OXYGEN
CYLINDERS
EFFECTIVITY SERIAL NUMBERS
70048
C19110464
C19070293
70050
C18081072
C18090622
70051
C18070784
C18031009
70054
C19051328
C18090918
70063 C18080108
70073 C19060066
B. Reason
1. Condition:
Some of the oxygen lines may have been contaminated by sealant or fibers
particles, which may result in potential partial blockage of the small orifices in
the oxygen lines and interfacing equipment, which in turn may lead to either a
reduction in oxygen flow or a fire hazard.
It has been assessed, based on the system design, that potential contaminants
would collect at the Oxygen Cylinder and Regulator Assemblies (OCRA’s)
filters.
2. Evidence:
The contaminants were identified to be torque sealant and cotton fibres that
could have been introduced into the oxygen system through the brazed line
joints.
3. Objective/Benefit:
This Service Bulletin instructs to replace the Oxygen Cylinder and Regulator
Assemblies (OCRA’s), with a new or a reworked unit.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Jan 26/2022 700−35−7502
Page 4 of 12

### Page 6

C. Description
This Service Bulletin gives instructions to:
− Get access to the oxygen cylinder assemblies in the LH forward cabin
enclosure,
− Remove only applicable oxygen cylinder assemblies,
− Return the removed units to one of the authorized repair shops,
− Install new or reworked oxygen cylinder assemblies, and
− Do the necessary tests to make sure that the system operate(s) correctly.
D. Compliance
Specified Time Compliance
Recommended within 36 months from this Service Bulletin release date (Basic
Issue).
NOTE: If it is not possible to complete all the instructions in this Service Bulletin
because of the aircraft configuration, submit an SRPSA for analysis and to
get an approved disposition to complete this Service Bulletin.
Standard SRPSA fees may apply. Refer to the Services section of the
Bombardier customer portal for the latest prices, rates and fees.
E. Approval
The technical content of this Service Bulletin has been approved under the
authority of Transport Canada Civil Aviation (TCCA) Design Approval Organization
(DAO) No. DAO #93−Q−02.
NOTES: 1. The technical content of this Service Bulletin is accepted by the FAA
under the Canada/USA bilateral Aviation Safety Agreement.
2. The technical content of this Service Bulletin is accepted by the JAA
and by EASA under the Canada/EU Bilateral Aviation Safety
Agreement.
F. Manpower
NOTES: 1. The man−hours given are to help you schedule the tasks given in this
Service Bulletin. The man−hours are for direct labor performed by an
experienced crew and do not include the time for familiarization,
planning, aircraft preparation in hangar such as towing and
positioning of scaffolds, removal of interior furnishings, repainting,
supervision and inspection.
For more information related to the manpower, refer to
SB 700−00−7502.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Jan 26/2022 700−35−7502
Page 5 of 12

### Page 7

2. Labor hours are based on the fact that the modification will be done at
the next scheduled maintenance task or inspection. Therefore no
man−hours are allotted to prepare the aircraft for maintenance or to
prepare for this Service Bulletin.
5 man−hours are necessary to do this modification.
The labor required to do this Service Bulletin is at no cost if:
− the work is done during new aircraft warranty period,
− the work is done at Bombardier Business Aviation Services (BBAS) or
Authorized Service Facilities (ASF), and
− this Service Bulletin is scheduled in less than 36 months from this Service
Bulletin release date (Basic Issue).
G. Material − Cost and Availability
No kit is necessary to do this modification. For material data refer to Paragraph 3.C.
The parts in Paragraph 3.B. are necessary to do this modification.
For all parts transactions, Bombardier Aviation’s current Spare Parts and
Component Repair Price Catalogue General Terms and Conditions apply. These
terms and conditions are found on the Bombardier Customer Portal at:
my.businessaircraft.bombardier.com
This Service Bulletin is covered by a dedicated schedule. Dedicated schedules are
used to reserve and manage inventory due to limited availability of rotable stock,
parts and/or kits. Parts are limited, therefore, advance part scheduling with our
In−Service Implementation Team (ISIT) is recommended prior to a maintenance
visit. They can be reached at bacs_isit@aero.bombardier.com. The parts will be
allocated on a first come first serve basis.
Should you require additional information, please contact your Regional Sales
Manager (RM) or Field Service Representative (FSR).
For more information on dedicated schedules, refer to SB 700−00−7502.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Jan 26/2022 700−35−7502
Page 6 of 12

### Page 8

Send the removed Oxygen Cylinder and Regulator Assemblies, Part
No. 806371−710 (qty 2), to either of the addresses shown below in exchange for
new or reworked units.
Learjet Inc. − Core Returns
251−A Wille Road
Des Plaines, Illinois
60018−1861
USA
or
Distribution Centre Frankfurt − Core Returns
Bombardier Aviation Company GmbH
Hans−Boeckler−Strasse 9
GROSS−GERAU Hesse 64521
Germany
Refer to your Material Return Authorization (MRA) form to find the applicable return
address.
NOTE: Bombardier Aviation is maintaining a rotable pool of replacement Oxygen
Cylinder and Regulator Assembly, to be supplied to the operators under
the terms and conditions given below:
− The removed Oxygen Cylinder and Regulator Assembly, Part No. 806371−710,
must be returned to Bombardier Aviation, Parts Services in less than 10 days of
receipt of replacement unit, with documentation showing the serial number of
the aircraft.
− If the removed Oxygen Cylinder and Regulator Assembly is not returned in less
than 10 days, the operator will be charged for the replacement unit.
The part is available at no cost if:
− ordered during new aircraft warranty period, and
− a no−charge purchase order is sent to Bombardier Aviation in less than
36 months from this Service Bulletin release date (Basic Issue).
Smart Parts does not pay for this recommended Service Bulletin at any time.
H. Tooling
The tool listed below is necessary to do this modification:
MODEL BD−700−2A12 (BD−700)
Basic Issue: Jan 26/2022 700−35−7502
Page 7 of 12

### Page 9

GSE REFERENCE NO. PART NO. DESCRIPTION
Commercially Available − Torque Wrench
NOTES: 1. Refer to the Global 7500 Illustrated Tool and Equipment Publication
(ITEP) to make sure that you use the correct equipment configuration.
2. Refer to the Liability Statement in the ITEP for the G7500 for
acceptable GSE equivalents.
3. This list is provided for quick reference. In case of discrepancy
between this list and the tools called in the AMP, WM, Chapter 20,
then the tools called in the AMP, WM prevail. Other approved
alternative tools are acceptable and can also be used.
I. Weight and Balance
No change.
J. Electrical Load Data
No change.
K. References
− Bombardier Aviation, Restriction and/or Special Instruction (RSI), C−70588,
Rev. −−.
− Global 7500 Aircraft Maintenance Publication (AMP), Chapters 6, 20, 24,
and 35.
− Global 7500 Supplementary Aircraft Maintenance Publication (SAMP),
Chapter 25.
− Global 7500 Illustrated Parts Data Publication (IPDP), Chapter 35.
L. Other Publications Affected
None.
M. Equivalent Service Bulletins
None.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Jan 26/2022 700−35−7502
Page 8 of 12

### Page 10

2. ACCOMPLISHMENT INSTRUCTIONS
NOTES: 1. All TASKs given in the procedures that follow are from the Global 7500
BD−700−2A12, Aircraft Maintenance Publication (AMP) unless otherwise
specified.
2. All references made to zones, access panels and/or doors, are from the
Global 7500 BD−700−2A12 Aircraft Maintenance Publication (AMP),
Chapter 6.
A. Aircraft Setup
(1) Obey all electrical/electronic safety precautions. Refer to
BD700−A−J24−00−00−00AAA−012A−A.
(2) Obey all oxygen safety precautions. Refer to
BD700−A−J35−00−00−00AAA−012A−A.
(3) Obey all Electrical Wiring Interconnection System (EWIS) safety precautions.
Refer to BD700−A−J20−16−00−00AAA−012A−A.
(4) In the flight compartment, on the eCB Page, set the circuit breakers that follow
to LOCK. Refer to BD700−A−J24−00−00−00AAA−561A−A.
NAME CB NUMBER/LOCATION
OXY CTRL PANEL SPDA2−2−18
OXYGEN SPDA2−1−18
(5) Remove the entrance−enclosure access panel. Refer to
SAMP BD700−A−J25−24−03−07.
B. Modification
NOTE: If it is not possible to complete all the instructions in this Service Bulletin
because of the configuration of the aircraft, submit an SRPSA for analysis
and get an approved disposition to complete this Service Bulletin.
(1) Examine the serial number of the oxygen cylinders, Part No. 806371−710
(qty 2), with the affected list in Paragraph 1.A., TABLE 1.
(a) If the serial number of the oxygen cylinder is not in the affected list, no
further action is necessary. Report the findings to Bombardier Aviation and
go to Paragraph 2.E., Close−out.
(b) If the serial number of the oxygen cylinder is in the affected list, do as
follow:
(i) Remove the affected oxygen cylinder and regulator assemblies, Part
No. 806371−710. Refer to BD700−A−J35−00−01−00AAA−520A−A.
(ii) Securely package and send the removed units for overhaul to the
address shown in Paragraph 1.G.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Jan 26/2022 700−35−7502
Page 9 of 12

### Page 11

(iii) Install the new or the overhauled oxygen cylinder and regulator
assemblies, Part No. 806371−710. Refer to
BD700−A−J35−00−01−00AAA−720A−A.
C. Testing
(1) In the flight compartment, on the eCB Page, set the circuit breakers that follow
to IN. Refer to BD700−A−J24−00−00−00AAA−761A−A.
NAME CB NUMBER/LOCATION
OXY CTRL PANEL SPDA2−2−18
OXYGEN SPDA2−1−18
(2) Do the quantity check for the flight−crew oxygen system. Refer to
BD700−A−J12−13−01−00AAA−200B−A.
(3) Do the leak check for the oxygen storage cylinder and the regulator. Refer to
BD700−A−J35−00−01−01AAA−364A−A.
(4) Do the operation test for the oxygen storage cylinder and the regulator. Refer
to BD700−A−J35−00−01−01AAA−320A−A.
D. Close−out
(1) Remove all tools, equipment and unwanted materials from the aircraft.
(2) Install the entrance−enclosure access panel. Refer to
SAMP BD700−A−J25−24−03−07.
E. Recording
When this Service Bulletin is completed, make an entry in the aircraft log and send
the attached Incorporation Notice to Bombardier Business Aircraft Customer
Services (BBACS).
For information, corrections, comments and/or feedback regarding Service Bulletins
released on the Customer Portal, please contact the Service Bulletin Group at the
following e−mail address:
bbad_SBgroup@aero.bombardier.com
3. MATERIAL INFORMATION
A. Kit
No kits required.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Jan 26/2022 700−35−7502
Page 10 of 12

### Page 12

B. Parts
The parts that follow are necessary to do this Service Bulletin and are available
from Bombardier Aviation Parts Services, Montreal:
NEW PART NO. QTY ITEM USED PARTNO. INSTRUCTIONS-DISPOSITION
806371−710 2
Oxygen
Cylinder and
Regulator
Assembly
(OCRA)
806371−710 Refer toParagraph 1.G.
M8791/1−005 4 Ring, Back−Up M8791/1−005 Discard
M25988/1−005 2
O−Ring,
Rubber,
Elastomer
M25988/
1−005 Discard
NOTE: The part number for the item listed above is subject to change without
revision to this Service Bulletin. In case of discrepancy between this list
and any other list, the Illustrated Parts Catalog prevails and shall be used
to determine the latest part number.
C. Material
The materials that follow, or equivalent, are necessary to do this Service Bulletin.
These can be purchased from a local supplier. Bombardier Aviation does not pay
for these consumables.
DESCRIPTION PARTNO./NAME SPECIFICATION QUANTITY
SUPPLIER
(SEE
NOTE)
Lockwire
(MS20995C20) 05−004 − As necessary Code: A
Grease 04−012 MIL−PRF−27617 As necessary Code: A
NOTES: 1. Refer to the table that follows for each suppliers address listed by
codes.
2. At time of release of this Service Bulletin, the information on the
supplier was valid and accurate. In the event that this information has
changed, the operator is encouraged to use the World Wide Web to
find a local supplier.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Jan 26/2022 700−35−7502
Page 11 of 12

### Page 13

SUPPLIERS ADDRESSES BY CODES
Code: A
Commercially Available
D. Publications
No publications required.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Jan 26/2022 700−35−7502
Page 12 of 12

### Page 14

700−35−7502 Basic Jan 26/2022
MODIFICATION – GENERAL –
REPLACEMENT OF THE OXYGEN CYLINDER AND REGULATOR
ASSEMBLY
bbad_SBgroup@aero.bombardier.com
NOTE: Please use Salesforce only for troubleshooting issues or when Engineering
deviation is necessary to accomplish the Service Bulletin modification.
SERVICE BULLETIN EVALUATION FORM
(Your ideas will help us provide better bulletins)
SERVICE BULLETIN: ISSUE: DATED:
TITLE:
For any information, correction(s), comment(s) and/or feedback regarding Service
Bulletins released on the Customer Portal, please contact the Service Bulletin Group
at the following email address:

### Page 15

SERVICE BULLETIN INCORPORATION SHEET − "700−35−7502"
Upon completion of the Service Bulletin, please fill−in, fax to
(514) 855−8798 or e−mail to Fracas at fracas.montreal@aero.bombardier.com
If you’re reporting Service Bulletin (SB) Incorporations to CAMP, sending
this Incorporation Sheet to Bombardier is not mandatory. If your aircraft is
on another tracking system, please contact Bombardier to make arrangements
for automated data submission.
700−35−7502 Basic
COMPLIED WITH
YES    NO    N/A
Actual hours to accomplish Service Bulletin:
* NOTES:
Aircraft Serial No. Aircraft Reg. No.
Airframe Hours: Airframe Landings
S.B. Incorporation Date Service Order No.
Facility incorporating S.B.
Name Signature Date
BOMBARDIER
SUBMISSION
Service Bulletin
Number
Rev. * Parts
Completed
Remarks/Reason
(Mandatory if N/A)
1. Where the Service Bulletin is divided into a number of parts (e.g., PARTS A,
B, C, D, etc.) which can be carried out separately, indicate only those parts
completed at this time.
2. For repetitive checks (usually PART A) only the initial check should be
reported unless otherwise stated in the Service Bulletin.
3. When more than one part is carried out at the same time, each part should
be reported.
4. Fill in ’Remark/Reason’ to explain compliance method when N/A is selected.(E.g. Part
not installed, N/A by effectivity, N/A by Part Serial Number, etc.
5. PCW means ’Previously Complied With’.
(dd/mm/yy)
Signature not required if sent by E−Mail (dd/mm/yy)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.