# Bombardier Service Bulletin 700-36-7503

Copy: No revision named ("SB 700-36-7503 Basic"), 157 pages: PDF https://openairdocs.org/files/sha256/6b/51/6b51d525d2159fd09c13e3e6a5c42f365424af7d2062535a05d583748f80fc46; text https://openairdocs.org/service-documents/bombardier/sb-700-36-7503/file/6b51d525d215.md. Rights: © Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2023-2139; AD 2024-06-08 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Bombardier](https://openairdocs.org/service-documents/bombardier.md)
- Type: Service bulletin (Service Bulletin)
- Number: 700-36-7503
- Page: https://openairdocs.org/service-documents/bombardier/sb-700-36-7503

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2024-06-08](https://openairdocs.org/ad/2024-06-08.md), effective Jun 5, 2024: No revision named

Also cited in [1 proposed AD](https://openairdocs.org/service-documents/bombardier/sb-700-36-7503/proposed.md).

## Text (157 pages)

Rights: © Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2023-2139; AD 2024-06-08 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

SPECIAL CHECK – BLEED-AIR LEAK-DETECTION SYSTEM –
SPECIAL CHECK ON THE KIDDE LEAK-DETECTION ELEMENTS
The information below is provided for your reference. For full details, including labor and part
coverage, please see corresponding paragraph contained within this bulletin.
RECOMMENDED
SPECIFIED TIME COMPLIANCE
COMPLIANCE TIME
Within 120 months or 3500 flight hours
whichever comes first from this Service
Bulletin release date (Basic Issue)
EFFECTIVITY: A/C Serial No. 70006 to 70096
MANPOWER: Refer to Paragraph 1.F.
CONTINUED AIRWORTHINESS (CAW)
FLEET CAMPAIGN YES NO
AIRWORTHINESS LIMITATIONS (AWL) NOYES
KITS and/or PARTS YES NO
TOOLING/GSE YES NO
PLANNING INFORMATION: See important
information at the start of Paragraph 1. YES NO
DEDICATED SCHEDULE NOYES
PREREQUISITE SERVICE BULLETINS: NA
NOTE: This Service Bulletin may be subject to an Airworthiness Directive which will make
it necessary to implement this Service Bulletin.
To place an order for parts, please call Bombardier Aviation Parts Services at:
514−855−2999 or 1−866−538−1247
SERVICE BULLETIN SUMMARY
my.businessaircraft.bombardier.com
MODEL BD−700−2A12 (BD−700)
ATA 36−22
PNEUMATIC
Basic Issue: Dec 23/2022 700−36−7503
Page 1 of 1
This Service Bulletin is available at:

### Page 2

SPECIAL CHECK – BLEED-AIR LEAK-DETECTION SYSTEM –
SPECIAL CHECK ON THE KIDDE LEAK-DETECTION ELEMENTS
1. PLANNING INFORMATION
NOTES:1 . Before you do this Service Bulletin, examine all STC, STA or
equivalent action changes to make sure that this Service Bulletin can
be completed.
2. To reduce operator downtime due to aircraft set−up, access, close−out
and return to service testing, Bombardier is recommending that the work is
done at the 144 month scheduled maintenance event while still respecting
the Service Bulletin compliance time. Refer to Paragraph 1.F.
3. Due to limited parts, facilities shall only order a loop when they have a
confirmed failure.
4. Send all Test Results to Bombardier Customer Support Engineering
through the SRPSA form to SRPSA@aero.bombardier.com or through
Salesforce for BAS Facilities.
5. For any technical issues, contact CSE, Technical Support, Global Express
by e−mail at SRPSA@aero.bombardier.com.
A. Effectivity
BD−700−2A12 aircraft, Serial No. 70006 to 70096.
NOTE: The instructions given in this Service Bulletin are only applicable to the
systems and parts installed at the time of delivery of the aircraft or as
changed by Bombardier Aviation Service Bulletin(s).
SERVICE BULLETIN
my.businessaircraft.bombardier.com
MODEL BD−700−2A12 (BD−700)
ATA 36−22
PNEUMATIC
Refer to applicable governmental agency regulations and requirements and make sure that the work described in this
Service Bulletin is performed in compliance with manufacturer’s recommendations and/or acceptable industry standards.
This document is proprietary to Bombardier Inc. and/or its affiliates and may not be reproduced or copied in any form or
by any means without the prior written consent of Bombardier Inc. and/or its affiliates.
 2022 Bombardier Inc.  All rights reserved
Learjet, Challenger, Global, are registered trademarks of Bombardier Inc. or its subsidiaries.
Basic Issue: Dec 23/2022 700−36−7503
Page 1 of 152
This Service Bulletin is available at:

### Page 3

B. Reason
1. Condition:
LDL elements delivered by Kidde Fire protection to LTS are not able to properly
detect leakages according to the temperature defined in the specification. Some
of the Leak Detection Loop (LDL) elements supplied by Kidde Aerospace &
Defense may be non−conforming and these elements present a risk due to the
inability to detect a bleed air leak
2. Evidence:
ATP software used to test the Leak Detection Loop (LDL) elements has certain
deficiency within the test equipment which result to a probability of having
certain non−complaint Leak Detection Loop (LDL) elements delivered to
Bombardier.
3. Objective/Benefit:
This Service Bulletin introduces an on−wing test procedure to test the
serviceability (examine the functionality) of each LDL element installed on the
aircraft and to replace those that have failed.
C. Description
This Service Bulletin gives general instructions to:
− Gain access to the pylons,
− Gain access to the equipment bay,
− Gain access under the baggage bay,
− Remove the belly fairings,
− Gain access to the left slats,
− Gain access to the right slats,
− Do the heat gun temperature verification, and
− Do the flight compartment setup.
This Service Bulletin gives instructions in PART A to:
− Do the test procedure at each location for the LDL elements in the Pylons,
− Fill out Appendix A with Test Results, and
− Replace the defective LDL element if necessary.
This Service Bulletin gives instructions in PART B to:
− Do the test procedure at each location for the LDL elements in the equipment
bay,
− Fill out Appendix A with Test Results, and
− Replace the defective LDL element if necessary.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 2 of 152

### Page 4

This Service Bulletin gives instructions in PART C to:
− Do the test procedure at each location for the LDL elements under the baggage
bay,
− Fill out Appendix A with Test Results, and
− Replace the defective LDL element if necessary.
This Service Bulletin gives instructions in PART D to:
− Do the test procedure at each location for the LDL elements in the belly fairings,
WUSS and fairing leading edge,
− Fill out Appendix A with Test Results, and
− Replace the defective LDL element if necessary.
This Service Bulletin gives instructions in PART E to:
− Do the test procedure at each location for the LDL elements in the left slats,
− Fill out Appendix A with Test Results, and
− Replace the defective LDL element if necessary.
This Service Bulletin gives instructions in PART F to:
− Do the test procedure at each location for the LDL elements in the right slats,
− Fill out Appendix A with Test Results, and
− Replace the defective LDL element if necessary.
D. Compliance
Recommended in less than 120 months or 3500 flight hours, whichever comes first
from this Service Bulletin release date (Basic Issue).
NOTE: If it is not possible to complete all the instructions in this Service Bulletin
because of the aircraft configuration, submit an SRPSA for analysis and to
get an approved disposition to complete this Service Bulletin. Standard
SRPSA fees may apply. Refer to the Services section of the Bombardier
Customer Portal for the latest prices, rates and fees.
E. Approval
The technical content of this Service Bulletin has been approved under the
authority of Transport Canada Civil Aviation (TCCA) Design Approval Organization
(DAO) No. DAO #93−Q−02.
NOTES: 1. The technical content of this Service Bulletin is accepted by the FAA
under the Canada/USA bilateral Aviation Safety Agreement.
2. The technical content of this Service Bulletin is accepted by EASA
under the Canada/EU bilateral Aviation Safety Agreement.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 3 of 152

### Page 5

F. Manpower
NOTES: 1. The man−hours given are to help you schedule the tasks given in this
Service Bulletin. The man−hours are for direct labor performed by an
experienced crew and do not include the time for familiarization,
planning, aircraft preparation in hangar such as towing and
positioning of scaffolds, removal of interior furnishings, repainting,
supervision and inspection.
For more information related to the manpower, refer to
SB 700−00−7502.
2. This Service Bulletin may require consumable materials that have
specific curing times (refer to Paragraph 3). The accumulated curing
time is not included in the man−hours and should be considered for
planning purposes before you schedule this Service Bulletin.
3. To reduce operator downtime due to aircraft set−up, access,
close−out and return to service testing, Bombardier is recommending
that the work is done at the 144 month scheduled maintenance event
while still respecting the Service Bulletin compliance time. Refer to
Paragraph 1.F.
1. If the aircraft is in scheduled heavy−maintenance: 214 total man−hours are
necessary to complete this Service Bulletin.
2. If the aircraft is outside scheduled heavy−maintenance: 404 total man−hours
are necessary to complete this Service Bulletin. The breakdown of the
man−hours is as follows:
− 17 man−hours are necessary to do PART A of this Service Bulletin.
− 23 man−hours are necessary to do PART B of this Service Bulletin.
− 7 man−hours are necessary to do PART C of this Service Bulletin.
− 85 man−hours are necessary to do PART D of this Service Bulletin.
− 116 man−hours are necessary to do PART E of this Service Bulletin.
− 116 man−hours are necessary to do PART F of this Service Bulletin.
− 40 man−hours are necessary for Repaint time of this Service Bulletin.
The labor required to do this Service Bulletin when the aircraft is in or outside
scheduled heavy−maintenance is at no cost if:
− the work is done at Bombardier Business Aviation Services (BBAS) or
Authorized Service Facilities (ASF), and
− this Service Bulletin is scheduled in less than 120 months from this Service
Bulletin release date (Basic Issue).
G. Material − Cost and Availability
NOTE: If material coverage is required due to a part failure, a scrap certificate will
be required. Claims will not be approved without the necessary scrap
certificate. Please see scrap certificate attached with the Service Bulletin.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 4 of 152

### Page 6

No kit is necessary to do this special check. For material data refer to
paragraph 3.C.
The parts in Paragraph 3.B. may be necessary to do this Service Bulletin.
NOTE: Due to limited parts, facilities shall only order a loop when they have a
confirmed failure.
The parts are available at no cost if:
− a no−charge purchase order is sent to Bombardier Aviation in less than
120 months from this Service Bulletin release date (Basic Issue).
For all parts transactions, Bombardier Aviation’s current Spare Parts and
Component Repair Price Catalogue General Terms and Conditions apply. These
terms and conditions are found on the Bombardier Customer Portal at:
my.businessaircraft.bombardier.com
Smart Parts does not pay for this recommended Service Bulletin at any time.
H. Tooling
The equipment and tools listed below are necessary to do this special check:
1. For Avionics Suite Method:
GSE REFERENCE
NO. PART NO. DESCRIPTION
Commercially Available − Blanket, Heat Insulating
Commercially Available HH501BJK or Fluke289 (or equivalent)
Digital Multimeter
Type K input 32−
1100°F (0−594°C)
Tolerance ±4°F (±2.2°C
or 0.75% (whichever is
greater)
32−104°F (0−40°C)
operate temp
Commercially Available STEINEL Model HG2320 E (or equivalent)
Heat Gun (capable of 0
to 350°C (32 to 662°F)
hot air delivery with
tolerance of ±10°F or
±5°C)
(Qty 2)
Commercially Available − Heat Gun, Extension,Flexible
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 5 of 152

### Page 7

GSE REFERENCE
NO. PART NO. DESCRIPTION
Commercially Available − Kevlar Sleeves
Commercially Available KMQSS−062U−12 orequivalent
K Type Thermocouple
(or equivalent)
Range 0 to 594°C (32
to 1100°F)
Allowable tolerance is
±2.2°C (±4°F or 0.75%,
whichever is greater.
Commercially Available −
Green & Black Sharpie
marker or equivalent
permanent marker
Commercially Available − Scraper, Non−Metallic
Commercially Available − Sharp Knife
Commercially Available STEINEL 07051 orequivalent Heat Gun Shield (Qty 2)
Commercially Available −
Stopwatch. Range 2
minutes minimum.
Tolerance 1 second
resolution (±5 secs over
range.
Commercially Available − Walkie Talkies
Commercially Available − Torque Wrench
2. For LCR Meter Test Method:
GSE REFERENCE
NO. PART NO. DESCRIPTION
27X78K−81−01 − Slat−riggingcontour−boards kit
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 6 of 152

### Page 8

GSE REFERENCE
NO. PART NO. DESCRIPTION
Commercially Available BK879B or equivalent
LCR Meter
1 kHz test frequency
±5%
0.6−1.0 Vrms test level
0 VDC ±0.02 VDC
0 to 40 kΩ Z impedance
(±5%)
0 to 40°C (32 to 104°F)
operate temp
Commercially Available HH501BJK or Fluke289 (or equivalent)
Digital Multimeter
Type K input 32−
1100°F (0−594°C)
Tolerance ±4°F (±2.2°C
or 0.75% (whichever is
greater)
32−104°F (0−40°C)
operate temp
Commercially Available STEINEL Model HG2320 E(or equivalent)
Heat Gun (capable of 0
to 350°C (32 to 662°F)
hot air delivery with
tolerance of ±10°F or
±5°C)
(Qty 2)
Commercially Available KMQSS−062U−12 orequivalent
K Type Thermocouple
(or equivalent)
Range 0 to 594°C (32
to 1100°F)
Allowable tolerance is
±2.2°C (±4°F or 0.75%,
whichever is greater.
Commercially Available 1146006−0254−00 LCR−LDL GSEHarness
Commercially Available 1148006−0254−00 LCR−LDL GSEHarness
Commercially Available −
Green & Black Sharpie
marker or equivalent
permanent marker
Commercially Available − Scraper, Non−Metallic
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 7 of 152

### Page 9

GSE REFERENCE
NO. PART NO. DESCRIPTION
Commercially Available − Sharp Knife
Commercially Available STEINEL 07051 orequivalent Heat Gun Shield (Qty 2)
Commercially Available −
Stopwatch. Range 2
minutes minimum.
Tolerance 1 second
resolution (±5 secs over
range.
Commercially Available − Walkie Talkies
Commercially Available − Torque Wrench
NOTES: 1. Refer to the Global 7500 Illustrated Tool and Equipment Manual
(ITEM) to make sure that you use the correct equipment
configuration.
2. Refer to the Liability Statement in the ITEM for the G7500 for
acceptable GSE equivalents.
3. This list is provided for quick reference. In case of discrepancy
between this list and the tools called in the AMP, WM, Chapter 20,
then the tools called in the AMP, WM prevail. Other approved
alternative tools are acceptable and can also be used.
I. Weight and Balance
No change.
J. Electrical Load Data
No change.
K. References
− TCCA Airworthiness Directive, (pending).
− Bombardier Aviation, Restriction and/or Special Instruction (RSI), C−70591,
Rev. NC.
− Liebherr, VSB CFD−F1958−26−01 Initial Issue, 6 May 2022.
− Kidde Aerospace and Defense SB CFD−26−1 Revision 6,
dated 28 February 2022.
− Global 7500, Aircraft Maintenance Publication (AMP), Chapters 6, 7, 12, 20, 24,
25, 27, 30, 36, 52, 53, 54 and 57.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 8 of 152

### Page 10

− Global 7500, Supplemental Aircraft Maintenance Publication (AMP),
Chapter 25.
− Appendix A − Test Results Sheet.
− Appendix B − Test Locations.
− SB Zeq Calculator Worksheet − (Attached).
− Scrap Certificate− (Attached).
L. Other Publications Affected
None.
M. Equivalent Service Bulletins
None.
2. ACCOMPLISHMENT INSTRUCTIONS
NOTES: 1. All TASKs given in the procedures that follow are from the Global 7500
BD−700−2A12, Aircraft Maintenance Publication (AMP) unless otherwise
specified.
2. All references made to zones, access panels and/or doors, are from the
Global 7500 BD−700−2A12 Aircraft Maintenance Publication (AMP),
Chapter 6.
3. References made to SAMP will be shown as per example
(BD700−A−J25−29−XX). Remaining numbers represented by XX will be
different for different operators depending on their configuration.
A. Aircraft Setup
(1) Pressure defuel aircraft. Refer to BD700−A−J12−11−03−00AAA−221A−A.
NOTE: Applicable for PART E and PART F only.
(2) Place aircraft on jacks and level. Refer to
BD700−A−J07−10−01−00AAA−172A−A.
NOTE: Applicable for PART E and PART F only.
(3) Obey all electrical/electronic safety precautions. Refer to
BD700−A−J24−00−00−00AAA−012A−A.
(4) Obey all bleed air leak detection system safety precautions. Refer to
BD700−A−J36−22−00−00AAA−913A−A.
(5) Set the circuit breakers that follow to LOCKED. Refer to
BD700−A−J24−00−00−02AAA−561A−A:
(a) On the DC Electrical Power Center (DC EPC) No. 2, open and tag the
circuit breakers that follow:
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 9 of 152

### Page 11

NAME CB NUMBER/LOCATION
IASC 1A DC−EPC2−E06
IASC 2B DC−EPC2−A02
(b) On the circuit breaker panel, open and tag the circuit breaker that follows:
NAME CB NUMBER/LOCATION
IASC 1B CBP−J06
(c) On the DC EPC No. 1, open and tag the circuit breaker that follows:
NAME CB NUMBER/LOCATION
IASC 2A DC−EPC1−A05
PART A − Pylon Access
(6) Remove the pylon fixed−trailing−edge access−panel (413BB/423BB). Refer to
BD700−A−J54−52−11−00AAA−520A−A.
(7) Remove the pylon center−box access−panels (412BT/422BT),
(412BB/422BB), and (412CB/422CB). Refer to
BD700−A−J54−52−09−00AAA−520A−A.
(8) Remove the ECS Precooler Inlet assembly.
BD700−A−J36−11−20−00AAA−520A−A.
PART B − Equipment Bay Access
(9) Do the procedure to open the aft equipment−compartment door (185KL). Refer
to BD700−A−J52−41−01−00AAA−540A−A.
PART C − Baggage Bay Access
(10) Remove the baggage compartment carpet. Refer to SAMP
BD700−A−J25−29−XX.
(11) Remove the aft fuselage floor−panels (251ALF) and (251DLF). Refer to
BD700−A−J53−41−01−00AAA−520A−A.
PART D − Belly Access, WUSS and Fairing Leading Edge
(12) Remove the left panel assembly (181AL). Refer to
BD700−A−J53−61−21−00AAA−520A−A.
(13) Remove the right panel assembly (182AR). Refer to
BD700−A−J53−61−23−00AAA−520A−A.
(14) Remove the forward under wing panel (183AB). Refer to
BD700−A−J53−63−11−00AAA−520A−A.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 10 of 152

### Page 12

(15) Remove the mid underwing panels (183BB) and (184BB). Refer to
BD700−A−J53−63−21−00AAA−520A−A.
(16) Remove the aft under wing panels (183CB) and (184CB). Refer to
BD700−A−J53−63−31−00AAA−520A−A.
(17) Remove the inboard−wing upper−leading−edge access−panels
(521AT/621AT) and (521BT/621BT). Refer to
BD700−A−J57−41−06−00AAA−520A−A.
(18) Remove the fixed−leading−edge outboard access panels (523BA/623BA).
Refer to BD700−A−J57−41−19−00AAA−520A−A.
(19) Remove the main−landing−gear wheel bins (165AZ), (165BZ), (166AZ) and
(166BZ). Refer to BD700−A−J53−30−01−00AAA−520A−A.
(20) Remove the fixed−leading−edge fixed cuff panels (523AA/623AA). Refer to
BD700−A−J57−41−17−00AAA−520A−A.
(21) Remove the left forward panel−assembly (185AB). Refer to
BD700−A−J53−67−11−00AAA−520A−A.
(22) Remove the left mid panel assembly (185CB). Refer to
BD700−A−J53−67−21−00AAA−520A−A.
(23) Remove the right forward panel−assembly (186AB). Refer to
BD700−A−J53−67−13−00AAA−520A−A.
(24) Remove the right mid panel−assembly (186CB). Refer to
BD700−A−J53−67−31−00AAA−520A−A.
PART E − Left Slat Access
(25) Remove the inboard−wing lower−leading−edge access−panels (521HB),
(521LB) and (521RB). Refer to BD700−A−J57−41−11−00AAA−520A−A.
(26) Remove the mid−wing lower leading−edge access−panels (531CB to 531SB).
Refer to BD700−A−J57−41−12−00AAA−520A−A.
(27) Remove the mid−wing lower leading−edge access−panels (531DB), (531JB)
and (531NB). Refer to BD700−A−J57−41−12−00AAA−520A−A.
(28) Remove the outboard−wing lower leading−edge access panels (541FB) and
(541LB). Refer to BD700−A−J57−41−13−00AAA−520A−A.
(29) Remove the inboard−wing lower−leading−edge access−panels (521NB). Refer
to BD700−A−J57−41−11−00AAA−520A−A.
(30) Remove the outboard−wing lower leading−edge access panels (541AB). Refer
to BD700−A−J57−41−13−00AAA−520A−A.
(31) Remove the slat No. 1 access panels (511AA), (511BA), (511DA), (511GA),
(511JA) and (511KA). Refer to BD700−A−J57−42−11−00AAA−520A−A.
(32) Remove the slat No. 2 access panels (512AA), (512BA), (512CA), (512DA)
and (512EA). Refer to BD700−A−J57−42−33−00AAA−520A−A.
(33) Remove the slat No. 3 access panels (513AA), (513BA), (513CA), (513DA)
and (513EA). Refer to BD700−A−J57−42−35−00AAA−520A−A.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 11 of 152

### Page 13

(34) Remove the slat No. 4 access panels (514AA), (514BA), (514CA), (514DA),
(514EA), (514FA) and (514GA). Refer to
BD700−A−J57−42−37−00AAA−520A−A.
PART F − Right Slat Access
(35) Remove the inboard−wing lower−leading−edge access−panels (621HB),
(621LB) and (621RB). Refer to BD700−A−J57−41−11−00AAA−520A−A.
(36) Remove the mid−wing lower leading−edge access−panels (631CB to 631SB).
Refer to BD700−A−J57−41−12−00AAA−520A−A.
(37) Remove the mid−wing lower leading−edge access−panels (631DB), (631JB)
and (631NB). Refer to BD700−A−J57−41−12−00AAA−520A−A.
(38) Remove the outboard−wing lower leading−edge access panels (641FB) and
(641LB). Refer to BD700−A−J57−41−13−00AAA−520A−A.
(39) Remove the inboard−wing lower−leading−edge access−panels (621NB). Refer
to BD700−A−J57−41−11−00AAA−520A−A.
(40) Remove the outboard−wing lower leading−edge access panels (641AB). Refer
to BD700−A−J57−41−13−00AAA−520A−A.
(41) Remove the slat No. 1 access panels (611AA), (611BA), (611DA), (611GA),
(611JA) and (611KA). Refer to BD700−A−J57−42−11−00AAA−520A−A.
(42) Remove the slat No. 2 access panels (612AA), (612BA), (612CA), (612DA)
and (612EA). Refer to BD700−A−J57−42−33−00AAA−520A−A.
(43) Remove the slat No. 3 access panels (613AA), (613BA), (613CA), (613DA)
and (613EA). Refer to BD700−A−J57−42−35−00AAA−520A−A.
(44) Remove the slat No. 4 access panels (614AA), (614BA), (614CA), (614DA),
(614EA), (614FA) and (614GA). Refer to
BD700−A−J57−42−37−00AAA−520A−A.
B. Special Check
NOTE: If it is not possible to complete all the instructions in this Service Bulletin
because of the configuration of the aircraft, submit an SRPSA for analysis
and get an approved disposition to complete this Service Bulletin.
(1) Testing to be performed in a hangar (well ventilated) or tarmac conditions with
no precipitation.
NOTE: Do not perform this test procedure when the ambient temperature is
below 0°C (32°F).
(2) Minimum manpower requirement is two (2). However, a third person may be
required to assist with heat gun operation.
C. Heat Gun Temperature Verification
WARNING: THE LEAK DETECTION LOOP ELEMENTS MUST NOT BE
EXPOSED TO DC VOLTAGES/CURRENTS.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 12 of 152

### Page 14

WARNING: HEAT GUN SHOULD NOT BE USED NEAR FLAMMABLE LIQUIDS
OR IN AN EXPLOSIVE ENVIRONMENT (FUMES, GASES OR
DUST). REMOVE MATERIALS OR DEBRIS THAT MAY BECOME
IGNITED FROM WORK AREA.
WARNING: DO NOT LEAVE TOOL UNATTENDED WHILE RUNNING OR
COOLING DOWN. OTHERWISE RISK OF FIRE.
CAUTION: DO NOT USE A METER THAT APPLIES A DC VOLTAGE. DO NOT
USE INSULATION RESISTANCE “MEGGER” TESTERS OR
DIELECTRIC VOLTAGE “HYPOT” TESTERS. THESE WILL
DAMAGE THE LEAK DETECTION LOOP ELEMENTS.
CAUTION: WHEN HEATING LEAK DETECTION LOOP ELEMENTS, THE HEAT
GUN SHALL BE POSITIONED SUCH THAT THE HEAT IS NOT
APPLIED WITHIN 1 INCH (2.5 CM) OF LEAK DETECTION LOOP
ELEMENT WHITE GROMMETS.
CAUTION: DO NOT DIRECT HEAT GUN AIRSTREAM AT CLOTHING, HAIR
OR OTHER BODY PARTS.
CAUTION: ALWAYS HOLD HEAT GUN BY PLASTIC ENCLOSURE. THE
METAL NOZZLE REQUIRES APPROXIMATELY 20 MINUTES TO
COOL TO WHERE IT CAN BE TOUCHED. DO NOT TOUCH
NOZZLE OR ACCESSORY TIPS UNTIL COOL.
CAUTION: DO NOT STORE HEAT GUN UNTIL NOZZLE HAS COOLED TO
ROOM TEMPERATURE. PLACE TOOL IN A CLEAR AREA AWAY
FROM COMBUSTIBLE MATERIALS WHILE COOLING.
CAUTION: DO NOT CUT OFF HEAT GUN AIRFLOW BY PLACING NOZZLE
TOO CLOSE TO WORK PIECE. KEEP INTAKE VENTS CLEAN AND
CLEAR OF OBSTRUCTIONS.
CAUTION: USE SHIELD MATERIALS AROUND THE HEATED AREA TO
PREVENT DAMAGE OR FIRE.
CAUTION: WEAR KEVLAR GLOVES AND SLEEVES WHEN WORKING IN
DIFFICULT AREAS WHERE THERE IS A RISK TO GET BURNT.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 13 of 152

### Page 15

CAUTION: PLACE TOOL ON A LEVEL SURFACE WHEN TOOL IS NOT
HANDHELD. PLACE CORD IN A POSITION THAT WON'T CAUSE
TIPPING. KEEP A FULLY CHARGED FIRE EXTINGUISHER
NEARBY.
NOTES: 1. Testing to be performed in a hangar (well ventilated) or tarmac
conditions with no precipitation.
2. Do not perform this test procedure when the ambient temperature
is below 0°C (32°F).
3. Minimum manpower requirement is two (2). However, a third
person may be required to assist with heat gun operation.
4. Keep a fully charged fire extinguisher nearby.
5. To ensure that the heat gun temperature is consistent during all
testing, this verification procedure shall be performed prior to
testing the first sensing element of each alarm set point and
repeated after every 4 hours of testing or when the sensing
element set point changes or when the ambient conditions in the
test location change but not less than once per shift.
(1) Securely attach the heat gun nozzle deflector to heat gun. Refer to Figure 1
and 3.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 14 of 152

### Page 16

SB700−36−6501_022
Temperature & Airflow
Figure 1
(2) Connect the thermocouple wire to the digital multimeter and set the meter to
measure temperature in °C/F.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 15 of 152

### Page 17

Digital Meter with Thermocouple
Figure 2
(3) Place the thermocouple at the center of the heat protection shield (not touching
the shield) at the approximate location the sensing elements will be placed as
identified in Figure 3.
NOTE: Figure 3 shows alternate positions for a dual loop configuration.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 16 of 152

### Page 18

Sensing
element
1−1.25’’
1.25−1.5’’
1.25−1.5’’
Sensing
element
Testing a single loop
Testing two loops
Heat gun outlet
Heat gun outlet
1
1
1
2 2
1−1.25’’
Test Item Placement within Heat Shield
Figure 3
(4) Turn ON heat gun and set airflow rate to maximum on the heat gun if the
setting is available.
(5) Set the heat gun temperature so the thermocouple reads the thermocouple test
temperature value specified in Table 1 for the correct salt type letter.
(6) Verify and record that the center thermocouple temperature value is within the
thermocouple test temperature value tolerance specified in Table 1.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 17 of 152

### Page 19

TABLE 1 - HEAT GUN TEMPERATURE SETTINGS
SALT
TYPE
TEMP
SET
POINT
THERMOCOUPLE
TEMPERATURE SYSTEM AREA
A
124°C
/
255°F
135 to 152 °C /
275 to 305° F
Wing Anti−ice
Wing Anti−ice
Bleed
ECS
Trim Air
Belly
Aft Equipment Bay
Pylon
Aft Equipment Bay
Aft Equipment Bay
D
204°C
/
400°F
219 to 236 °C /
427 to 457 °F
Wing Anti−ice
Wing Anti−ice
Wing Anti−ice
WUSS 1
FLE
Slats 1 − 4
R
180°C
/
356°F
194 to 211 °C /
381 to 411 °F Wing Anti−ice WUSS 2
U 99°C /210°F 109 to 126 °C /228 to 258 °F Trim Air Baggage Bay
NOTES: 1. It is recommended that the heat gun setting temperature be
initially set high enough such to achieve a thermocouple test
temperature that uses approximately ½ the allowable
temperature tolerance defined in Table 1
2. For heat guns with a digital display, the heat gun display
temperature will typically be higher than the temperature at the
thermocouple.
3. During heat gun temperature settings calibration to achieve the
thermocouple test temperature, the thermocouple temperature
will slightly vary up and down according to the thermal regulation
of the heat gun. The temperature values recorded should be the
average of the observed results.
(7) Move and place the thermocouple approximately 0.33 inch (0.85 cm) from the
centerline of the heat protection shield left or right at the approximate location
the sensing element will be place as shown in Figure 3.
NOTES: 1. If measuring the 2nd location right of centerline, route
thermocouple from the right. If measuring the 2nd location left of
centerline, route thermocouple from the left.
2. The heat gun 2nd or off−axis location may be below the lower
limit in the Table 1 as the temperature may reduce near the
edges left or right of center test position.
(8) Record the second or off−axis thermocouple value.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 18 of 152

### Page 20

(9) Calculate the two (2) point average temperature of the center point and second
or off−axis thermocouple readings.
EXAMPLE
SALT TYPE
LETTER
CENTER
THERMOCOUPLE
TEMPERATURE
(T CENTER)
2ND LOCATION
(OFF AXIS)
THERMOCOUPLE
TEMPERATURE
(T 2ND)
2 PT AVERAGE
THERMOCOUPLE
TEST
TEMPERATURE
A 290°F / 143°C 260°F / 127°C 275°F / 135°C
Formula: 2pt Average Thermocouple Test Temperature
= (T center + T 2nd)/2
= (290°F + 260°F)/2
= 275°F
(10) If the above 2 point (pt) average thermocouple test temperature value is not
within the tolerance allowed in Table 1 using a center and left off axis position
or center and right off axis position, attempt steps (3) through (9) trying the
opposite side of the tested center and left or right off axis position until the 2 pt
average thermocouple test temperature value is within the tolerance limits.
This will mitigate some heat gun variability. If the testing is not successful,
replace the heat gun with one with a more uniform output.
NOTE: It is recommended this value be near or approximately at the
mid−point of the temperature range defined by the tolerance in
Table 1.
(11) Repeat steps (1) to (10) for the second heat gun, if required.
NOTE: To ensure that the heat gun temperature is consistent during all
testing, this verification procedure shall be performed prior to testing
the first sensing element of each alarm set point and repeated after
every 4 hours of testing or when the sensing element set point
changes or when the ambient conditions in the test location change
but not less than once per shift.
D. Cockpit Setup for Avionics Suite Test Method
NOTE: Not applicable to slats for PART E and PART F.
(1) Verify the conditions that follow:
(a) Aircraft Weight on Wheels (WoW).
(b) All 4 EECs (Engine FADECs) are functional.
(c) ADSP x4 are functional.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 19 of 152

### Page 21

(2) Do the procedures that follow to initiate IASC PBIT functioning:
(a) Set aircraft AC power ON.
Remove the tag and set the circuit breakers that follow to IN. Refer to
BD700−A−J24−00−00−02AAA−761A−A.
NAME CB NUMBER/LOCATION
IASC 2B DC−EPC2−A02
IASC 2A DC−EPC1−A05
IASC 1B CBP−J06
IASC 1A DC−EPC2−E06
(b) Access the PBIT STATUS page as follows. Refer to Figure 4.
(i) Using either CCP1 or CCP2 in the center console, scroll to the left
upper corner of any of the multifunction windows (MFW).
(ii) Click on M. The main menu screen is displayed. Select MAINT.
Select Perform LRU/System Operations from the Maintenance Main
Menu.
(iii) Select ATA 21, Air Management System.
(iv) Select AMS−Pressurization Data from the list displayed.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 20 of 152

### Page 22

AMS−Pressurization Data
Figure 4
(c) Wait for the PBIT Status to complete. IASC 1 and 2 must show a 1 for
OFV PBIT ENDED.
(d) If the PBIT ENDED does not show in step (c), verify the conditions that
follow:
(i) Aircraft Weight on Wheels (WoW)
(ii) Bleed manifold pressure is less than 16 psig
(iii) All 4 EECs (Engine FADECs) are functional
(iv) LH & RH BPS/PIPS are functional on the ECS and BAMS OMS page
(v) ADSP x4 are functional
(vi) Maintenance panel (Aircraft) set to NORM
(e) If PBIT execution at Step 2.(c) is not successful and needs to be repeated,
do as follows:
(i) Set aircraft power to OFF, wait 10 seconds and set the power to ON.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 21 of 152

### Page 23

(or)
(ii) Set the circuit breakers that follow to LOCKED and then set to IN, in
the following order. Refer to BD700−A−J24−00−00−02AAA−561A−A
and BD700−A−J24−00−00−02AAA−761A−A.
NAME CB NUMBER/LOCATION
IASC 2B DC−EPC2−A02
IASC 2A DC−EPC1−A05
IASC 1B CBP−J06
IASC 1A DC−EPC2−E06
(f) Wait at least 5 minutes in order for IASC PBIT to check short and open
circuit.
(g) Verify that no CAS or Info messages are related to LDLs.
− TRIM AIR FAIL − DUAL LOOP ELEMENT INOP
− AIR COND / PRESS − TRIM LOOP ONE ELEMENT INOP
− L BLEED SYS FAIL− DUAL LOOP ELEMENT INOP
− BLEED − L BLEED LOOP ONE ELEMENT INOP
− R BLEED SYS FAIL− DUAL LOOP ELEMENT INOP
− BLEED − R BLEED LOOP ONE ELEMENT INOP
− WING A/ICE FAIL − L WIPS DUAL LOOP ELEMENT INOP
− ICE PROT − L WIPS LOOP ONE ELEMENT INOP
− WING A/ICE FAIL − R WIPS DUAL LOOP ELEMENT INOP
− ICE PROT − R WIPS LOOP ONE ELEMENT INOP
− WING A/ICE FAIL − L WING DUAL LOOP ELEMENT INOP
− ICE PROT − L WING LOOP ONE ELEMENT INOP
− WING A/ICE FAIL − R WING DUAL LOOP ELEMENT INOP
− ICE PROT − R WING LOOP ONE ELEMENT INOP
− 21 AIR COND / PRESS − IASC 1A FAULT
− 21 AIR COND / PRESS − IASC 1B FAULT
− 21 AIR COND / PRESS − IASC 1C FAULT
− 21 AIR COND / PRESS − IASC 2A FAULT
− 21 AIR COND / PRESS − IASC 2B FAULT
− 21 AIR COND / PRESS − IASC 2C FAULT
− 21 AIR COND / PRESS − IASC 1A INOP
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 22 of 152

### Page 24

− 21 AIR COND / PRESS − IASC 1B INOP
− 21 AIR COND / PRESS − IASC 2A INOP
− 21 AIR COND / PRESS − IASC 2B INOP
− 21 AIR COND / PRESS − IASC 1C INOP
− 21 AIR COND / PRESS − IASC 2C INOP
− 21 AIR COND / PRESS − IASC 1 DMC COM LOSS
− 21 AIR COND / PRESS − IASC 1 AFD COM LOSS
− 21 AIR COND / PRESS − IASC 2 DMC COM LOSS
− 21 AIR COND / PRESS − IASC 2 AFD COM LOSS
(h) Access the Leak Detection Loop Data OMS page as follows. Refer to
Figure 11.
(i) Using either CCP1 or CCP2 in the center console, scroll to the left
upper corner of any of the MFW.
(ii) Click on M. The main menu screen is displayed. Select MAINT.
Select Perform LRU/System Operations from the Maintenance Main
Menu.
(iii) Select ATA 21, Air Management System.
(iv) Select LEAK DETECTION LOOP from the list displayed.
(v) Check that all values on all parameters for LEAK LOCALIZATION,
SHORTED LOOP DETECTION, and OPEN LOOP DETECTION read
zero.
NOTE: Humidifier will read “1” on OPEN LOOP DETECTION since it
is not installed.
(vi) Troubleshoot any unusual readings prior to continuing with this test.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 23 of 152

### Page 25

AMS−LEAK DETECTION DATA OMS PAGE
AMS−Leak Detection Data OMS page
Figure 11
E. PART A − Pylons
(1) Use the Dual Channel method described in Paragraph 2.L. to do the testing for
all the locations listed in Appendix B, Figure 5.
F. PART B − Aft Equipment Bay
(1) Use the Dual Channel method described in Paragraph 2.L. to do the testing for
all the locations listed in Appendix B, Figure 6.
G. PART C − Baggage Bay
(1) Use the Dual Channel method described in Paragraph 2.L. to do the testing for
all the locations listed in Appendix B, Figure 7.
H. PART D − Belly Access, WUSS and Fairing Leading Edge
(1) Turn PRESSURIZATION overhead panel OFV 1 “Closed” PBA, when testing
TP29.2. Turn ON immediately when test is complete.
(2) Use the Dual Channel method described in Paragraph 2.L. to do the testing for
all the locations listed in Appendix B, Figure 8.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 24 of 152

### Page 26

I. PART E − Left Slat Setup and Testing
NOTE: The procedure that follows is applicable only for left slat.
(1) Connect the electrical power to the aircraft. Refer to
BD700−A−J24−00−00−00AAA−730A−A.
(2) Extend the slats. Refer to BD700−A−J27−81−00−00AAA−398B−A.
(3) Apply masking tape, 2 in (50.8 mm) wide and 12 in (304.8 mm) long, over wing
surface such that when the slats are fully retracted, approximately 1 in
(25.4 mm) of tape will be shown over the fixed wing surface area above the
slat edge. The other half of the tape will be hidden under the slat edge. Refer
to Figure 12.
MASKING TAPE
LOCATION
A B C D E
Slat Panel Trailing Edge
Figure 12
(4) Retract the slats. Refer to BD700−A−J27−81−00−00AAA−398C−A.
(5) Using a SHARPIE marker (or equivalent), trace an alignment line over the
masking tape where the edge of the slat upper surface meets up with the fixed
wing surface, from slat No. 1 to slat No. 4 at the locations shown in Figure 13.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 25 of 152

### Page 27

A B C
D E
ALIGNMENT LINES
ALIGNMENT LINES
ALIGNMENT LINES
ALIGNMENT LINES
ALIGNMENT LINES
Figure 13
(6) Using a SHARPIE marker (or equivalent) and a straight edge, trace an
alignment line at the slat leading edge surfaces between slat No. 1 & No. 2,
slat No. 2 & No. 3 and slat No. 3 & No. 4. Refer to Figure 14.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 26 of 152

### Page 28

ALIGNMENT LINES
Figure 14
(7) On the Multi−Function Keyboard Panel (MKP), push the SYS button to get
access to the FLT CTRL synoptic page. Refer to Figure 15.
(a) Make sure that the FLT CTRL synoptic page shows on the Adaptive Flight
Display (AFD).
(b) On the Cursor Control Panel (CCP), push the MENU pushbutton.
(c) From the main menu, select MAINT.
(d) From the MAINT sub−menu, select MAINTENANCE.
(e) From the Maintenance Menu, select Perform LRU/System Operations.
(f) On the LRU/System Operations page, do the steps that follows:
(i) From the View combo box, select all ATAs.
(ii) From the Select ATA combo box, select 27 Flight Controls.
(iii) From the Select LRU/System combo box, select SFECU−1S−Motor
and Sensor Parameters page.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 27 of 152

### Page 29

Figure 15
(8) Under SFECU−1S and SFECU−2S columns, record the LEFT SLAT PSU
readings. Refer to Figure 16.
SLAT PSU SFECU-1S SFECU-2S
LEFT SLAT PSU
(9) Manually extend the slats. Refer to BD700−A−J27−81−00−00AAA−398B−A.
(10) Under SFECU−1S and SFECU−2S columns, record the LEFT SLAT PSU
readings. Refer to Figure 16.
SLAT PSU SFECU-1S SFECU-2S
LEFT SLAT PSU
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 28 of 152

### Page 30

Figure 16
(11) In the flight compartment, on the eCB Page, set the circuit breakers that follow
to LOCK. Refer to BD700−A−J24−00−00−00AAA−561A−A.
NAME CB NUMBER/LOCATION
SFECU 1 DC SLAT SPDA2−4−1
SFECU 2 DC FLAP SPDA2−4−2
(12) On the emergency electrical−power−center No. 1, open and tag the circuit
breaker that follows. Refer to BD700−A−J24−00−00−02AAA−561A−A.
NAME CB NUMBER/LOCATION
SFECU 1 DC FLAP EMEREPC−A01
(13) On the circuit breaker panel, open and tag the circuit breakers that follow.
Refer to BD700−A−J24−00−00−02AAA−561A−A.
NAME CB NUMBER/LOCATION
SFECU 1 AC FLAP CBP−E04
SFECU 2 DC SLAT CBP−E06
SFECU 2 AC SLAT CBP−B03
(14) On the AC electrical−power−center No. 2, open and tag the circuit breakers
that follow. Refer to BD700−A−J24−00−00−02AAA−561A−A.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 29 of 152

### Page 31

NAME CB NUMBER/LOCATION
SFECU 1 AC SLAT AC−EPC2−A05
SFECU 2 AC FLAP AC−EPC2−A03
(15) CAUTION: DO NOT PUSH IN THE AC CIRCUIT BREAKERS (SFECU 1
AC SLAT / SFECU 2 AC SLAT) FOR PARAGRAPHS 2.I.(15)
TO 2.I.(85).
DO NOT PUSH IN THE AC CIRCUIT BREAKERS (SFECU 1
AC SLAT / SFECU 2 AC SLAT) AS THIS WILL RUN A BITE
CHECK OF THE SLAT/FLAP CONTROL UNIT AND INITIATE
MOVEMENT OF THE SLATS. IF THIS OCCURS, THE
RESOLVER READINGS WILL BE DISTURBED AND SLAT
RIGGING WILL BE REQUIRED.
(16) Before disconnecting torque tube from support bearing, Part
No. G02701050−001, locate torque tube position by marking a straight
alignment line across the torque tube and the shaft of the support bearing. This
will help restore connection at both locations to original configuration upon
installation. Refer to Figure 17.
ALIGNMENT LINEA
A
Figure 17
(17) At slat No. 1, disconnect torque tube, at both locations, from support bearing,
Part No. G02701050−001, and retain hardware. Slide torque tube to disengage
it from the inboard side of slat No. 1 inboard actuator.
(18) Manually extend all slats then use brake release tool (ts−1052, Pt. No. GSE
27X78K−53−03) to engage the asymmetry brake. Refer to
BD700−A−J27−81−00−00AAA−398B−A.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 30 of 152

### Page 32

(19) On slats No. 1, No. 2 and No. 3, locate the outboard actuators. Mark a straight
alignment line across the torque tube and the outboard actuator shaft. Use a
SHARPIE marker or equivalent to draw the alignment line. Refer to Figure 18.
ALIGNMENT LINE
Figure 18
(20) Remove the leading edge seals between slat No. 1 & slat No. 2, slat No. 2 &
slat No. 3, slat No. 3 & slat No. 4 and slat No. 4 & integrated wing tip. Refer to
BD700−A−J57−41−09−00AAA−520A−A.
CAUTION: BE CAREFUL WHEN HANDLING THE SLAT DISCONNECT
SENSOR. MOLDED FUSES ARE DELICATE AND CAN
EASILY BE DAMAGED. IF DAMAGED, REPLACE SLAT
DISCONNECT SENSOR.
(21) Detach but do not completely remove the slat disconnect sensor from each slat
structure as follows. Refer to Figure 19.
(a) Sufficiently loosen but do not remove bolt P1.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 31 of 152

### Page 33

0.392 in
(9.96 mm)
+0.031 in
−0.010 in
(+0.79 mm)
(−0.25 mm)
TYPICAL SLATS INTERSECTION LOCATION
AIRCRAFT MOUNTING BRACKETS AND BOLTS
(LHS SHOWN, RHS SYMMETRICAL)
BRACKET
(REF)
P1
P2
PIN
MOULDED
FUSE
Figure 19
(b) Remove and retain bolt, P2, washers and nut. Discard cotter pin.
(c) Slide the slat disconnect sensor away from bolt P1 then place the slat
disconnect sensor to the side and away from the slat split. Refer to
Figure 20.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 32 of 152

### Page 34

Figure 20
(22) Remove flexible joints between wing anti−icing supply ducts at slat No.1 & slat
No.2, slat No.2 & slat No.3 and slat No.3 & slat No. 4. Refer to Figure 21 and
BD700−A−J30−12−11−00AAA−520A−A.
Figure 21
(23) Disconnect wire harness connectors (qty 3) interconnecting the bleed detection
loop harnesses between slats No. 1 & No. 2, No. 2 & No. 3 and No. 3 & No. 4.
Refer to Figure 22.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 33 of 152

### Page 35

Figure 22
(24) Figure 23 intentionally left blank.
(25) Manually retract the slats. Refer to BD700−A−J27−81−00−00AAA−398C−A.
(26) Disconnect the marked torque tubes from the outboard slat actuators on slats
No. 1, No. 2, and No. 3. This will allow independent movement of each slat.
(27) Manually extend slat No. 1 and No. 3. Keep slat No. 2 and No. 4 retracted.
Refer to BD700−A−J27−81−00−00AAA−398B−A.
NOTE: Use of the brake release tool (ts−1052, Pt. No. GSE 27X78K−53−03)
to disengage the asymmetry brake is not necessary for this step.
(28) Remove the hardware attaching close−out rib to slat No. 1. Refer to
BD700−A−J57−42−25−00AAA−520A−A.
NOTE: It is not necessary to remove the hardware attaching the close−out rib
to the outboard piccolo duct.
(29) Carefully slide out the outboard piccolo duct together with the close−out rib
from slat No. 1. Refer to BD700−A−J30−12−13−00AAA−520A−A.
(30) Carefully slide out the inboard piccolo duct from slat No. 1. Refer to
BD700−A−J30−12−13−00AAA−520A−A.
(31) Do the procedure to remove the slat No. 1 access panels (511CZ), (511EZ),
(511FZ) and (511HZ). Refer to BD700−A−J57−42−11−00AAA−520A−A and
Figure 24.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 34 of 152

### Page 36

511AA
611AA511BA
611BA511DA611DA511GA611GA511JA611JA511KA
611KA
511HZ
611HZ
511FZ
611FZ
511EZ
611EZ
511CZ
611CZB
B
Figure 24
(32) Remove bleed leak−detection−elements (inboard, middle and outboard) from
slat No. 1. Refer to BD700−A−J36−22−09−00AAA−520A−A.
NOTE: After sliding out the inboard and outboard trays from slat No. 1, place
them on a clean bench. Keep the bleed leak−detection−elements
attached to the trays. The two middle elements are not attached to a
tray.
(33) Remove the hardware attaching close−out rib to slat No. 3. Refer to
BD700−A−J57−42−29−00AAA−520A−A.
NOTE: It is not necessary to remove the hardware attaching the close−out rib
to the piccolo duct.
(34) Carefully slide out the piccolo duct with the close−out rib from slat No. 3. Refer
to BD700−A−J30−12−17−00AAA−520A−A.
(35) Remove the tray with the bleed leak−detection−elements from slat No. 3. Refer
to BD700−A−J36−22−13−00AAA−520A−A.
NOTE: After sliding out the tray from slat No. 3, place it on a clean bench.
Keep the bleed leak−detection−elements attached to the tray at this
time.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 35 of 152

### Page 37

(36) Manually retract slats No. 1 and No. 3 then manually extend slats No. 2 and
No. 4. Refer to BD700−A−J27−81−00−00AAA−398C−A for slat manual
retraction and BD700−A−J27−81−00−00AAA−398B−A for slat manual
extension.
NOTE: The use of the brake release tool (ts−1052, Pt. No. GSE
27X78K−53−03) is necessary to disengage the asymmetry brake for
slat No. 4 only.
(37) Remove the hardware attaching close−out rib to slat No. 2. Refer to
BD700−A−J57−42−27−00AAA−520A−A.
NOTE: It is not necessary to remove the hardware attaching the close−out rib
to the piccolo duct.
(38) Carefully slide out the piccolo duct with the close−out rib from slat No. 2. Refer
to BD700−A−J30−12−15−00AAA−520A−A.
(39) Remove the tray with the bleed leak−detection−elements from slat No. 2. Refer
to BD700−A−J36−22−11−00AAA−520A−A.
NOTE: After sliding out the tray from the slat, place it on a clean bench. Keep
the bleed leak−detection−elements attached to the tray at this time.
(40) Remove the hardware attaching close−out rib to slat No. 4. Refer to
BD700−A−J57−42−31−00AAA−520A−A.
NOTE: It is not necessary to remove the hardware attaching the close−out rib
to the piccolo duct.
(41) Carefully slide out the piccolo duct with the close−out rib from slat No. 4. Refer
to BD700−A−J30−12−19−00AAA−520A−A.
NOTE: After sliding out the piccolo tube, place it on a clean bench.
(42) Remove the tray with the bleed leak−detection−elements from slat No. 4. Refer
to BD700−A−J36−22−15−00AAA−520A−A.
NOTE: After sliding out the tray from the slat, place it on a clean bench. Keep
the bleed leak−detection−elements attached to the tray at this time.
(43) Test each bleed leak−detection−element individually using the LCR Meter Test
Method (Slats Only) as per paragraph 2.K, at all the LH slat locations shown in
Appendix B, Figure 9.
NOTE: It will be necessary to detach each bleed leak−detection−element
from the support clamps and hardware to allow proper placement of
the heat gun at the required test point.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 36 of 152

### Page 38

Figure 25
(44) Replace each bleed leak−detection−element that fails the test in
paragraph 2.K. Refer to Appendix B, Figure 9.
1. If LDL element fails, the LDL element must be removed from the aircraft
and red tagged. The failed LDL element must be replaced with a
serviceable unit as defined in VSB CFD−F1958−26−01.
2. If LDL element fails, mark the LDL element as failed in Appendix A and
record the LDL element Serial No. in Appendix A.
3. Failed elements shall be sent back to Bombardier. Refer to Paragraph 1.G.
for disposal/shipping instructions.
(45) Secure each bleed leak−detection−element to the tray support clamps with the
hardware retained.
(46) Install the tray with the bleed leak−detection−elements in slat No. 4. Refer to
BD700−A−J36−22−15−00AAA−720A−A.
(47) Install the piccolo duct with the close−out rib in slat No. 4. Refer to
BD700−A−J30−12−19−00AAA−720A−A.
(48) Install the hardware attaching close−out rib to slat No. 4. Refer to
BD700−A−J57−42−31−00AAA−720A−A.
(49) Install the tray with the bleed leak−detection−elements in slat No. 2. Refer to
BD700−A−J36−22−11−00AAA−720A−A.
(50) Install the piccolo duct with the close−out rib in slat No. 2. Refer to
BD700−A−J30−12−15−00AAA−720A−A.
(51) Install the hardware attaching close−out rib to slat No. 2. Refer to
BD700−A−J57−42−27−00AAA−720A−A.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 37 of 152

### Page 39

(52) Manually retract slats No. 2 and No. 4 then manually extend slats No. 1 and
No. 3. Refer to BD700−A−J27−81−00−00AAA−398C−A for slat manual
retraction and BD700−A−J27−81−00−00AAA−398B−A for slat manual
extension.
NOTE: Use brake release tool (ts−1052, Pt. No. GSE 27X78K−53−03) to
disengage the asymmetry brake for slat No. 4 only.
(53) Install the tray with the bleed leak−detection−elements in slat No. 3. Refer to
BD700−A−J36−22−13−00AAA−720A−A.
(54) Install the piccolo duct with the close−out rib in slat No. 3. Refer to
BD700−A−J30−12−17−00AAA−720A−A.
(55) Install the hardware attaching close−out rib to slat No. 3. Refer to
BD700−A−J57−42−29−00AAA−720A−A.
(56) Install bleed leak−detection−elements (inboard, middle and outboard) in slat
No. 1. Refer to BD700−A−J36−22−09−00AAA−720A−A.
(57) Install the outboard piccolo duct with the close−out rib in slat No. 1. Refer to
BD700−A−J30−12−13−00AAA−720A−A.
(58) Install the inboard piccolo duct in slat No. 1. Refer to
BD700−A−J30−12−13−00AAA−720A−A.
(59) Install the hardware attaching close−out rib to slat No. 1. Refer to
BD700−A−J57−42−25−00AAA−720A−A.
(60) Manually extend the slats No. 2 and No. 4. Refer to
BD700−A−J27−81−00−00AAA−398B−A.
NOTE: Use brake release tool (ts−1052, Pt. No. GSE 27X78K−53−03) to
disengage the asymmetry brake for slat No. 4 only.
(61) With all slats extended, use brake release tool (ts−1052, Pt. No. GSE
27X78K−53−03) to engage the asymmetry brake.
(62) Do the procedure to install the slat No. 1 access panels (511CZ), (511EZ),
(511FZ) and (511HZ). Refer to BD700−A−J57−42−11−00AAA−720A−A and
Figure 26.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 38 of 152

### Page 40

511AA
611AA511BA
611BA511DA611DA511GA611GA511JA611JA511KA
611KA
511HZ
611HZ
511FZ
611FZ
511EZ
611EZ
511CZ
611CZB
B
Figure 26
(63) CAUTION: DO NOT PUSH IN THE AC CIRCUIT BREAKERS (SFECU 1
AC SLAT / SFECU 2 AC SLAT) AS THIS WILL RUN A BITE
CHECK OF THE SLAT/FLAP CONTROL UNIT AND INITIATE
MOVEMENT OF THE SLATS. IF THIS OCCURS, THE
RESOLVER READINGS WILL BE DISTURBED AND SLAT
RIGGING WILL BE REQUIRED.
(64) Set the SFECU DC circuit breakers, as follows:
(a) In the flight compartment, on the eCB Page, set the circuit breakers that
follow to IN. Refer to BD700−A−J24−00−00−00AAA−761A−A.
NAME CB NUMBER/LOCATION
SFECU 1 DC SLAT SPDA2−4−1
SFECU 2 DC FLAP SPDA2−4−2
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 39 of 152

### Page 41

(b) On the emergency electrical−power−center No. 1, remove the tag and
close the circuit breaker that follows. Refer to
BD700−A−J24−00−00−02AAA−761A−A.
NAME CB NUMBER/LOCATION
SFECU 1 DC FLAP EMEREPC−A01
(c) On the circuit breaker panel, remove the tags and close the circuit
breakers that follow. Refer to BD700−A−J24−00−00−02AAA−761A−A.
NAME CB NUMBER/LOCATION
SFECU 2 DC SLAT CBP−E06
(65) On the Multi−Function Keyboard Panel (MKP), push the SYS button to get
access to the FLT CTRL synoptic page.
(a) Make sure that the FLT CTRL synoptic page shows on the Adaptive Flight
Display (AFD).
(b) On the Cursor Control Panel (CCP), push the MENU pushbutton.
(c) From the main menu, select MAINT.
(d) From the MAINT sub−menu, select MAINTENANCE.
(e) From the Maintenance Menu, select Perform LRU/System Operations.
(f) On the LRU/System Operations page, do the steps that follow:
(i) From the View combo box, select all ATAs.
(ii) From the Select ATA combo box, select 27 Flight Controls.
(iii) From the Select LRU/System combo box, select SFECU−1S−Motor
and Sensor Parameters page.
(66) With the torque tube connected to inboard actuator of slat No. 4, rotate the
torque tube, by hand only, to retract the slat until the reading on the LEFT
SLAT PSU is less than the original reading recorded in step (10) then extend
the slat by rotating the torque tube by hand again so that the original reading in
step (10) is obtained.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 40 of 152

### Page 42

SLAT PSU SFECU-1S SFECU-2S
LEFT SLAT PSU
NOTES: 1. Use brake release tool (ts−1052, Pt. No. GSE 27X78K−53−03) to
disengage the asymmetry brake for slat No. 4 only.
2. Three persons are required to perform this task. One in the flight
compartment to monitor and communicate the PSU reading to
the two persons at the slat.
3. One full turn of the torque tube is equivalent to approximately
0.070 to 0.10 in (1.78 to 2.54 mm) of actual actuator surface
movement.
4. The slat is first retracted beyond the original reading then
extended brought to the original reading to remove any slack in
the system.
(67) Use brake release tool (ts−1052, Part No. GSE 27X78K−53−03) to engage the
asymmetry brake.
(68) Align slat No. 3 with slat No. 4 until the alignment marks on the slat leading
edge surfaces line up. Refer to Figure 27.
ALIGNMENT LINES
Figure 27
(69) Slide the opposite end of the torque tube to the outboard slat actuator of slat
No. 3 and attach with hardware retained. Make sure the alignment marks line
up before hardware is installed. Secure with lockwire at the end only. Refer to
Figure 28.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 41 of 152

### Page 43

ALIGNMENT LINE
Figure 28
(70) Repeat steps 66 to 69, to align slat No. 2 with slat No. 3.
(71) Repeat steps 66 to 69, to align slat No. 1 with salt No. 2.
(72) Finally connect and secure the torque tube at slat No. 1 to the support bearing
with the hardware retained. Make sure the alignment marks line up before
hardware is installed. Secure with lockwire at the end only. Refer to Figure 29.
ALIGNMENT LINEA
A
Figure 29
(73) Use brake release tool (ts−1052, Pt. No. GSE 27X78K−53−03) to disengage
the asymmetry brake.
(74) Manually retract slats No. 1, No. 2, No. 3 and No. 4 simultaneously until the
original reading on the LEFT SLAT PSU recorded in step (8) is obtained. Refer
to BD700−A−J27−81−00−00AAA−398C−A.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 42 of 152

### Page 44

(75) Make sure that the edge of No. 1, No. 2, No. 3 and No. 4 slat surfaces align
with the markings on the tape (refer to paragraph 2.I.(5)). If a surface is off by
0.070 to 0.10 in (1.78 to 2.54 mm), it means that the torque tube was off in
either direction or not correctly connected (refer to paragraphs 2.I.(66) to (75)).
(76) Use brake release tool (ts−1052, Pt. No. GSE 27X78K−53−03) to engage the
asymmetry brake.
(77) Install wing anti−icing supply duct flexible joints between: slat No. 1 & slat No.
2, slat No. 2 & slat No. 3 and slat No. 3 & slat No. 4. Refer to
BD700−A−J30−12−11−00AAA−720A−A.
(78) With all torque tubes connected with retaining hardware, secure bolts with
lockwire.
(79) Connect wire harness connectors interconnecting bleed detection loops
between slats No.1, No.2, No.3 and No. 4.
CAUTION: BE CAREFUL WHEN HANDLING THE SLAT DISCONNECT
SENSOR. MOLDED FUSES ARE DELICATE AND CAN
EASILY BE DAMAGED. IF DAMAGED, REPLACE SLAT
DISCONNECT SENSOR.
(80) Install the slat disconnect sensor at each slat structure as follows. Refer to
Figure 30.
NOTE: Make sure to install the sensor in the same location from where it was
removed.
(a) Slide the sensor against bolt P1 then install bolt P2 with hardware
retained. Do not torque at this time.
(b) Maintain a gap of 0.392 in (9.96mm) between the aircraft pin and the
sensor arms as shown in the illustration.
(c) With a torque wrench, tighten the bolts 16 to 18 lbf in (1.81 to 2.03 Nm).
Refer to BD700−A−J20−50−00−00AAA−711A−A.
(d) Install cotter pin, Part No. MS24665−88, on nut at P2.
(e) Secure bolt P1 with lockwire. Refer to
BD700−A−J20−80−01−00AAA−720A−A.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 43 of 152

### Page 45

0.392 in
(9.96 mm)
+0.031 in
−0.010 in
(+0.79 mm)
(−0.25 mm)
TYPICAL SLATS INTERSECTION LOCATION
AIRCRAFT MOUNTING BRACKETS AND BOLTS
(LHS SHOWN, RHS SYMMETRICAL)
BRACKET
(REF)
P1
P2
PIN
MOULDED
FUSE
Figure 30
(81) Install leading edge seals between slat No. 1 & slat No. 2, slat No. 2 & slat No.
3, slat No. 3 & slat No. 4 and, slat No. 4 & integrated wingtip. Refer to
BD700−A−J57−41−09−00AAA−720A−A.
(82) Make sure slat/flap control lever is in the 0 degree position.
(83) In the flight compartment, on the eCB Page, set the circuit breakers that follow
to LOCK. Refer to BD700−A−J24−00−00−00AAA−561A−A.
NAME CB NUMBER/LOCATION
SFECU 1 DC SLAT SPDA2−4−1
SFECU 2 DC FLAP SPDA2−4−2
(84) On the emergency electrical−power−center No. 1, open and tag the circuit
breaker that follows. Refer to BD700−A−J24−00−00−02AAA−561A−A.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 44 of 152

### Page 46

NAME CB NUMBER/LOCATION
SFECU 1 DC FLAP EMEREPC−A01
(85) On the circuit breaker panel, open and tag the circuit breakers that follow.
Refer to BD700−A−J24−00−00−02AAA−561A−A.
NAME CB NUMBER/LOCATION
SFECU 2 DC SLAT CBP−E06
(86) Push in all the AC circuit breakers first and then push in all the DC circuit
breakers, as follows. Must be done in that sequence otherwise faults will be
observed.
(a) On the circuit breaker panel, remove the tags and close the circuit
breakers that follow. Refer to BD700−A−J24−00−00−02AAA−761A−A.
NAME CB NUMBER/LOCATION
SFECU 1 AC FLAP CBP−E04
SFECU 2 AC SLAT CBP−B03
(b) On the AC electrical−power−center No. 2, remove the tags and close the
circuit breakers that follow. Refer to
BD700−A−J24−00−00−02AAA−761A−A.
NAME CB NUMBER/LOCATION
SFECU 1 AC SLAT AC−EPC2−A05
SFECU 2 AC FLAP AC−EPC2−A03
(c) In the flight compartment, on the eCB Page, set the circuit breakers that
follow to IN. Refer to BD700−A−J24−00−00−00AAA−761A−A.
NAME CB NUMBER/LOCATION
SFECU 1 DC SLAT SPDA2−4−1
SFECU 2 DC FLAP SPDA2−4−2
(d) On the emergency electrical−power−center No. 1, remove the tag and
close the circuit breaker that follows. Refer to
BD700−A−J24−00−00−02AAA−761A−A.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 45 of 152

### Page 47

NAME CB NUMBER/LOCATION
SFECU 1 DC FLAP EMEREPC−A01
(e) On the circuit breaker panel, remove the tags and close the circuit
breakers that follow. Refer to BD700−A−J24−00−00−02AAA−761A−A.
NAME CB NUMBER/LOCATION
SFECU 2 DC SLAT CBP−E06
(87) Go to MDC page, select SFECU−1S rigging and clear latched faults. Then
select SFECU−2S rigging and clear latched faults.
(88) Go to flight synoptic page and ensure that no slat/flap control unit messages
are posted.
(89) Extend slats fully down then retract to full up position and ensure no fault
messages are posted. Repeat for 2 other cycles.
(90) Access OMS page for SFECU rigging, if resolver readings are off by greater
than 0.1, then perform electrical rigging for the leading edge slat system. Refer
to BD700−A−J27−81−00−00AAA−275B−A.
(91) Perform slat rigging check for each slat. Refer to
BD700−A−J27−81−17−00AAA−275E−A (for Slat No. 1),
BD700−A−J27−81−21−00AAA−275E−A (for Slat No. 2),
BD700−A−J27−81−25−00AAA−275E−A (for Slat No. 3) and
BD700−A−J27−81−29−00AAA−275E−A (for Slat No. 4).
(92) Extend slats and remove the masking tape from the fixed wing upper surface.
Refer to Figure 31. Refer to BD700−A−J27−51−00−00AAA−912A−A.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 46 of 152

### Page 48

A B C
D E
ALIGNMENT LINES
ALIGNMENT LINES
ALIGNMENT LINES
ALIGNMENT LINES
ALIGNMENT LINES
Figure 31
(93) Make sure slat/flap control lever is in 0 deg position.
(94) Remove all traces of the markings from the slat leading edge surfaces between
slat No. 1 & No. 2, slat No. 2 & No. 3 and slat No. 3 & No. 4. Refer to
Figure 32.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 47 of 152

### Page 49

ALIGNMENT LINES
Figure 32
J. PART F − Right Slat Setup and Testing
NOTE: The procedure that follows is applicable only for right slat.
(1) Connect the electrical power to the aircraft. Refer to
BD700−A−J24−00−00−00AAA−730A−A.
(2) Extend the slats. Refer to BD700−A−J27−81−00−00AAA−398B−A.
(3) Apply masking tape, 2 in (50.8 mm) wide and 12 in (304.8 mm) long, over wing
surface such that when the slats are fully retracted, approximately 1 in
(25.4 mm) of tape will be shown over the fixed wing surface area above the
slat edge. The other half of the tape will be hidden under the slat edge. Refer
to Figure 12.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 48 of 152

### Page 50

MASKING TAPE
LOCATION
ABCDE
Slat Panel Trailing Edge
Figure 12
(4) Retract the slats. Refer to BD700−A−J27−81−00−00AAA−398C−A.
(5) Using a SHARPIE marker (or equivalent), trace an alignment line over the
masking tape where the edge of the slat upper surface meets up with the fixed
wing surface, from slat No. 1 to slat No. 4 at the locations shown in Figure 13.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 49 of 152

### Page 51

A B C
D E
ALIGNMENT LINES
ALIGNMENT LINES
ALIGNMENT LINES
ALIGNMENT LINES
ALIGNMENT LINES
Figure 13
(6) Using a SHARPIE marker (or equivalent) and a straight edge, trace an
alignment line at the slat leading edge surfaces between slat No. 1 & No. 2,
slat No. 2 & No. 3 and slat No. 3 & No. 4. Refer to Figure 14.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 50 of 152

### Page 52

ALIGNMENT LINES
Figure 14
(7) On the Multi−Function Keyboard Panel (MKP), push the SYS button to get
access to the FLT CTRL synoptic page. Refer to Figure 15.
(a) Make sure that the FLT CTRL synoptic page shows on the Adaptive Flight
Display (AFD).
(b) On the Cursor Control Panel (CCP), push the MENU pushbutton.
(c) From the main menu, select MAINT.
(d) From the MAINT sub−menu, select MAINTENANCE.
(e) From the Maintenance Menu, select Perform LRU/System Operations.
(f) On the LRU/System Operations page, do the steps that follows:
(i) From the View combo box, select all ATAs.
(ii) From the Select ATA combo box, select 27 Flight Controls.
(iii) From the Select LRU/System combo box, select SFECU−1S−Motor
and Sensor Parameters page.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 51 of 152

### Page 53

Figure 15
(8) Under SFECU−1S and SFECU−2S columns, record the RIGHT SLAT PSU
readings. Refer to Figure 16.
SLAT PSU SFECU-1S SFECU-2S
RIGHT SLAT PSU
(9) Manually extend the slats. Refer to BD700−A−J27−81−00−00AAA−398B−A.
(10) Under SFECU−1S and SFECU−2S columns, record the RIGHT SLAT PSU
readings. Refer to Figure 16.
SLAT PSU SFECU-1S SFECU-2S
RIGHT SLAT PSU
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 52 of 152

### Page 54

Figure 16
(11) In the flight compartment, on the eCB Page, set the circuit breakers that follow
to LOCK. Refer to BD700−A−J24−00−00−00AAA−561A−A.
NAME CB NUMBER/LOCATION
SFECU 1 DC SLAT SPDA2−4−1
SFECU 2 DC FLAP SPDA2−4−2
(12) On the emergency electrical−power−center No. 1, open and tag the circuit
breaker that follows. Refer to BD700−A−J24−00−00−02AAA−561A−A.
NAME CB NUMBER/LOCATION
SFECU 1 DC FLAP EMEREPC−A01
(13) On the circuit breaker panel, open and tag the circuit breakers that follow.
Refer to BD700−A−J24−00−00−02AAA−561A−A.
NAME CB NUMBER/LOCATION
SFECU 1 AC FLAP CBP−E04
SFECU 2 DC SLAT CBP−E06
SFECU 2 AC SLAT CBP−B03
(14) On the AC electrical−power−center No. 2, open and tag the circuit breakers
that follow. Refer to BD700−A−J24−00−00−02AAA−561A−A.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 53 of 152

### Page 55

NAME CB NUMBER/LOCATION
SFECU 1 AC SLAT AC−EPC2−A05
SFECU 2 AC FLAP AC−EPC2−A03
(15) CAUTION: DO NOT PUSH IN THE AC CIRCUIT BREAKERS (SFECU 1
AC SLAT / SFECU 2 AC SLAT) FOR PARAGRAPHS 2.J.(15)
TO 2.J.(85).
DO NOT PUSH IN THE AC CIRCUIT BREAKERS (SFECU 1
AC SLAT / SFECU 2 AC SLAT) AS THIS WILL RUN A BITE
CHECK OF THE SLAT/FLAP CONTROL UNIT AND INITIATE
MOVEMENT OF THE SLATS. IF THIS OCCURS, THE
RESOLVER READINGS WILL BE DISTURBED AND SLAT
RIGGING WILL BE REQUIRED.
(16) Before disconnecting torque tube from support bearing, Part
No. G02701050−001, locate torque tube position by marking a straight
alignment line across the torque tube and the shaft of the support bearing. This
will help restore connection at both locations to original configuration upon
installation. Refer to Figure 17.
ALIGNMENT LINE
A
A
Figure 17
(17) At slat No. 1, disconnect torque tube, at both locations, from support bearing,
Part No. G02701050−001, and retain hardware. Slide torque tube to disengage
it from the inboard side of slat No. 1 inboard actuator.
(18) Manually extend all slats then use brake release tool (ts−1052, Pt. No. GSE
27X78K−53−03) to engage the asymmetry brake. Refer to
BD700−A−J27−81−00−00AAA−398B−A.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 54 of 152

### Page 56

(19) On slats No. 1, No. 2 and No. 3, locate the outboard actuators. Mark a straight
alignment line across the torque tube and the outboard actuator shaft. Use a
SHARPIE marker or equivalent to draw the alignment line. Refer to Figure 18.
ALIGNMENT LINE
Figure 18
(20) Remove the leading edge seals between slat No. 1 & slat No. 2, slat No. 2 &
slat No. 3, slat No. 3 & slat No. 4 and slat No. 4 & integrated wing tip. Refer to
BD700−A−J57−41−09−00AAA−520A−A.
CAUTION: BE CAREFUL WHEN HANDLING THE SLAT DISCONNECT
SENSOR. MOLDED FUSES ARE DELICATE AND CAN
EASILY BE DAMAGED. IF DAMAGED, REPLACE SLAT
DISCONNECT SENSOR.
(21) Detach but do not completely remove the slat disconnect sensor from each slat
structure as follows. Refer to Figure 19.
(a) Sufficiently loosen but do not remove bolt P1.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 55 of 152

### Page 57

0.392 in
(9.96 mm)
+0.031 in
−0.010 in
(+0.79 mm)
(−0.25 mm)
TYPICAL SLATS INTERSECTION LOCATION
AIRCRAFT MOUNTING BRACKETS AND BOLTS
(LHS SHOWN, RHS SYMMETRICAL)
BRACKET
(REF)
P1
P2
PIN
MOULDED
FUSE
Figure 19
(b) Remove and retain bolt P2, washers and nut. Discard cotter pin.
(c) Slide the slat disconnect sensor away from bolt P1 then place the slat
disconnect sensor to the side and away from the slat split. Refer to
Figure 20.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 56 of 152

### Page 58

Figure 20
(22) Remove flexible joints between wing anti−icing supply ducts at slat No. 1 & slat
No. 2, slat No. 2 & slat No. 3 and slat No. 3 & slat No. 4. Refer to Figure 21
and BD700−A−J30−12−11−00AAA−520A−A.
Figure 21
(23) Disconnect wire harness connectors (qty 3) interconnecting the bleed detection
loop harnesses between slats No. 1 & No. 2, No. 2 & No. 3 and No. 3 & No. 4.
Refer to Figure 22.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 57 of 152

### Page 59

Figure 22
(24) Figure 23 intentionally left blank.
(25) Manually retract the slats. Refer to BD700−A−J27−81−00−00AAA−398C−A.
(26) Disconnect the marked torque tubes from the outboard slat actuators on slats
No. 1, No. 2, and No. 3. This will allow independent movement of each slat.
(27) Manually extend slat No. 1 and No. 3. Keep slat No. 2 and No. 4 retracted.
Refer to BD700−A−J27−81−00−00AAA−398B−A.
NOTE: Use of the brake release tool (ts−1052, Pt. No. GSE 27X78K−53−03)
to disengage the asymmetry brake is not necessary for this step.
(28) Remove the hardware attaching close−out rib to slat No. 1. Refer to
BD700−A−J57−42−25−00AAA−520A−A.
NOTE: It is not necessary to remove the hardware attaching the close−out rib
to the outboard piccolo duct.
(29) Carefully slide out the outboard piccolo duct together with the close−out rib
from slat No. 1. Refer to BD700−A−J30−12−13−00AAA−520A−A.
(30) Carefully slide out the inboard piccolo duct from slat No. 1. Refer to
BD700−A−J30−12−13−00AAA−520A−A.
(31) Do the procedure to remove the slat No. 1 access panels (611CZ), (611EZ),
(611FZ) and (611HZ). Refer to BD700−A−J57−42−11−00AAA−520A−A and
Figure 24.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 58 of 152

### Page 60

511AA
611AA511BA
611BA511DA611DA511GA611GA511JA611JA511KA
611KA
511HZ
611HZ
511FZ
611FZ
511EZ
611EZ
511CZ
611CZB
B
Figure 24
(32) Remove bleed leak−detection−elements (inboard, middle and outboard) from
slat No. 1. Refer to BD700−A−J36−22−09−00AAA−520A−A.
NOTE: After sliding out the inboard and outboard trays from slat No. 1, place
them on a clean bench. Keep the bleed leak−detection−elements
attached to the trays. The two middle elements are not attached to a
tray.
(33) Remove the hardware attaching close−out rib to slat No. 3. Refer to
BD700−A−J57−42−29−00AAA−520A−A.
NOTE: It is not necessary to remove the hardware attaching the close−out rib
to the piccolo duct.
(34) Carefully slide out the piccolo duct with the close−out rib from slat No. 3. Refer
to BD700−A−J30−12−17−00AAA−520A−A.
(35) Remove the tray with the bleed leak−detection−elements from slat No. 3. Refer
to BD700−A−J36−22−13−00AAA−520A−A.
NOTE: After sliding out the tray from slat No. 3, place it on a clean bench.
Keep the bleed leak−detection−elements attached to the tray at this
time.
MODEL BD−700−2A12 (BD−700)
Basic Issue: Dec 23/2022 700−36−7503
Page 59 of 152

The text continues at https://openairdocs.org/service-documents/bombardier/sb-700-36-7503/file/6b51d525d215.md?from=61

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.