### Page 1

TEMPORARY REVISION ALI−0192
REF#: 84ALI_198_R 4−28 FUEL SYSTEM LIMITATIONS
The contents of this Temporary Revision have been approved by the Chief, Engineering (or designate), National Aircraft Cerification Branch, Transport Canada Civil Aviation
Date 24 Apr 2018 Signed Philippe Ngassam
FILING INSTRUCTIONS: This Temporary Revision (TR) replaces the TR ALI−0181. In the Maintenance Requirements Manual Part 2, remove
the TR ALI−0181 from Section 4−28 Fuel System Limitations of the Maintenance Requirements Manual Part 2 and
insert this new Temporary Revision in front of page 1.
Record the incorporation of this Temporary Revision on the RECORD OF TEMPORARY REVISIONS sheet at the front
of the Manual.
Keep this Temporary Revision until the normal revision service puts this information into the Maintenance
Requirements Manual.
DESCRIPTION: This Temporary Revision (TR) replaces the entire Section 4−28 Fuel System Limitations with the updates as follows:
Revises the task 284000−405 Description by removing the Note, task now applies to all.
Revises the task 284000−417 Description Applicability (was For non−APU lines, couplings and fittings: Post Modsum
(4−126330), or Post Modsums (4−126330 and 4−126537), or Post Modsum (4−126336). For APU lines, couplings and
fittings (Modsum 4−302000): Post Modsums (4−901425 or 4−901423), is now applicable to all).
New task 284000−419 is added.
Replaced TR ALI−0181 was issued previously to Section 4−28 to update task 284000−406. Revised Applicability (was
(Post Modsum 4−113299) or (Post Modsum 4−121195) or (Post Modsum 4−110139) or (Post Modsum 4−113977) or
(Post Modsum 4−113978) or (Post Modsum 4−124440), is now applicable to all).
Replaced TR ALI−0179 was issued previously to Section 4−28 to update task 284000−406. Revised Applicability (was
(Post Modsum 4−113299) or (Post Modsum 4−121195) or (Post Modsum 4−110139)), (is now (Post Modsum
4−113299) or (Post Modsum 4−121195) or (Post Modsum 4−110139) or (Post Modsum 4−113977) or (Post Modsum
4−113978) or (Post Modsum 4−124440)).
E
AIRWORTHINESS LIMITATIONS
  PSM 1−84−7 −  Maintenance Requirements Manual − Part 2
  EFFECTIVITY: DHC−8−400 Series
                           
                           
                           4−28
TR ALI−0192
Page 1 of 4
Apr 24/2018
TEMPORARY
REVISION
TEMPORARY
REVISION

### Page 2

FUEL SYSTEM LIMITATIONS
28 − FUEL SYSTEM LIMITATIONS
ALI TASK
NUMBER
CONF
LTR
MODEL
EFFECTIVITY
DESCRIPTION INTERVAL TASK
TYPE
284000−401  ALL FUEL QUANTITY GAUGING: Detailed Inspection of the Metal Overall Shield
on the Fuel Quantity Gauging System
DET18000 FH
or
108 MO
284000−402  ALL FUEL QUANTITY GAUGING: Detailed Inspection of the Fuel Probe Harness
Inside the Fuel Tank
APPLICABILITY: (Post Modsum 4−126370) or (Post Modsum 4−126336)
DET18000 FH
or
108 MO
284000−403  ALL FUEL QUANTITY GAUGING: Detailed Inspection of the Low Level Float
Switch Harness Inside the Fuel Tank
APPLICABILITY: (Post Modsum 4−126370) or (Post Modsum 4−126336)
DET18000 FH
or
108 MO
284000−404  ALL FUEL QUANTITY GAUGING: Detailed Inspection of the High Level Sensor
Harness Inside the Fuel Tank
APPLICABILITY: (Post Modsum 4−126370) or (Post Modsum 4−126336)
DET18000 FH
or
108 MO
284000−405  ALL FUEL STORAGE: Detailed Inspection of the Self Bonding Couplings Inside
the Fuel Tank
DET18000 FH
or
108 MO
284000−406  ALL FUEL STORAGE: Detailed Inspection of the Teflon Sleeve on the Fuel Tank
Vent Line
DET18000 FH
or
108 MO
284000−407  ALL FUEL STORAGE: Detailed Inspection of the Sealant Around the Anchor Nuts
at Access Panels, Sta. YW 42.000 to YW 191.200
DET18000 FH
or
108 MO
E
AIRWORTHINESS LIMITATIONS
  PSM 1−84−7 −  Maintenance Requirements Manual − Part 2
  EFFECTIVITY: DHC−8−400 Series
                           
                           
                           4−28
TR ALI−0192
Page 2 of 4
Apr 24/2018
TEMPORARY
REVISION
TEMPORARY
REVISION

### Page 3

FUEL SYSTEM LIMITATIONS
28 − FUEL SYSTEM LIMITATIONS
ALI TASK
NUMBER
CONF
LTR
MODEL
EFFECTIVITY
DESCRIPTION INTERVAL TASK
TYPE
284000−408  ALL FUEL STORAGE: Detailed Inspection of the Access Panel to Wing Skin
Mating Surfaces and Access Panel Gasket, Sta. YW 191.200 to YW 425.019
DET18000 FH
or
108 MO
284000−409  ALL FUEL STORAGE: Detailed Inspection of the Dome Nut on the Fuel Tank
Water Drain Valve
DET18000 FH
or
108 MO
284000−410  ALL FUEL STORAGE: Detailed Inspection of the Sealant on the Vent Line Support
Bracket and Attachment Hardware, Sta. YW 42.000
APPLICABILITY: (Post Modsum 4−126330) or (Post Modsum 4−122242)
DET18000 FH
or
108 MO
284000−411  ALL FUEL QUANTITY GAUGING: Functional Check of the Fuel Quantity Metal
Overall Shield for Electrical Bonding
FNC18000 FH
or
108 MO
284000−412  ALL FUEL STORAGE: Functional Check of the Fuel Tank Water Drain Valve for
Electrical Bonding
FNC18000 FH
or
108 MO
284000−413  ALL FUEL STORAGE: Functional Check of the Magnetic Dipstick for Electrical
Bonding
FNC18000 FH
or
108 MO
284000−414  ALL FUEL STORAGE: Operational Check of the Low Level Float Switch OPC18000 FH
or
108 MO
E
AIRWORTHINESS LIMITATIONS
  PSM 1−84−7 −  Maintenance Requirements Manual − Part 2
  EFFECTIVITY: DHC−8−400 Series
                           
                           
                           4−28
TR ALI−0192
Page 3 of 4
Apr 24/2018
TEMPORARY
REVISION
TEMPORARY
REVISION

### Page 4

FUEL SYSTEM LIMITATIONS
28 − FUEL SYSTEM LIMITATIONS
ALI TASK
NUMBER
CONF
LTR
MODEL
EFFECTIVITY
DESCRIPTION INTERVAL TASK
TYPE
284000−415  ALL FUEL STORAGE: Functional Check of the Auxiliary Boost Pump for Electrical
Bonding
FNC18000 FH
or
108 MO
284000−416  ALL FUEL STORAGE: Functional Check of the High Level Sensor for Electrical
Bonding
FNC18000 FH
or
108 MO
284000−417  ALL FUEL STORAGE: Functional Check of the Fuel Tank Components and
Plumbing Lines for Electrical Bonding
FNC18000 FH
or
108 MO
284000−418  ALL FUEL STORAGE: Detailed Inspection of the Teflon Sleeve on the Fuel Tank
Lines and Clearances Between Fuel Lines and Structure
APPLICABILITY: (Post Modsum 4−113643 and Post Modsum 4−113754) or
(Post Modsum 4−113643 and Post Modsum 4−113745 and Post Modsum
4−113754) or (Post Modsum 4−113762)
DET18000 FH
or
108 MO
284000−419  ALL Detailed Inspection of the Fuel Tank Plumbing Lines Isolator Assemblies
APPLICABILITY: Post Modsum 4−113969 or Post Modsum 4−113970
DET18000 FH
or
108 MO
E
AIRWORTHINESS LIMITATIONS
  PSM 1−84−7 −  Maintenance Requirements Manual − Part 2
  EFFECTIVITY: DHC−8−400 Series
                           
                           
                           4−28
TR ALI−0192
Page 4 of 4
Apr 24/2018
TEMPORARY
REVISION
TEMPORARY
REVISION

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.