### Page 1

NONDESTRUCTIVE TESTING MANUAL
Part 4 -  Ultrasonic
Part 4
Part 5
Part 6
Part 7
Part 8
Part 9
Page 1
53- 61- 110
EFFECTIVITY: SEE PARAGRAPH 2
TR 53-
TEMPORARY REVISION 53-
FILING INSTRUCTIONS: Insert this Temporary Revision facing TASK Part 4, 53- 61- 110.
Record the incorporation of this Temporary Revision on the yellow
RECORD OF TEMPORARY REVISIONS sheet at the front of this
volume.
Keep this Temporary Revision until Revision 45 incorporates this
information into the Nondestructive Testing Manual.
DESCRIPTION: This Temporary Revision revises TASK Part 4, 53- 61- 110 SPECIAL
DETAILED INSPECTION OF THE ENGINE SUPPORT BEAM UPPER
AND LOWER CAP ANGLES AT FS625.3 AND FS640.0 BETWEEN
LBL36.2 AND RBL36.2 to introduce a new calibration reference
standard (CRS) and make other miscellaneous changes.
Part 4
of 10
130
130
Sep 15/23

### Page 2

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−110
EFFECTIVITY: SEE PARAGRAPH 2
SPECIAL DETAILED INSPECTION OF THE ENGINE SUPPORT BEAM UPPER AND LOWER CAP
ANGLES  AT FS625.3 AND FS640.0, BETWEEN LBL36.2 AND RBL36.2
1. General
A. Function
(1) This inspection procedure is used to detect subsurface cracks propagating from the
fasteners holes in the top and bottom webs, 601−35006−3 and 601−35006−5 respectively, 
of the engine support beam covered by the transversal angles, along WL119.12 and WL111.
09 between LBL38.00 and RBL38.00 at FS625.30.
NOTE: This subsurface inspection is to be done at the same time as the eddy
current inspection (Refer to Part 6, 53−61−110).
This inspection procedure applies to both sides of the aircraft.
B. Reference Information
(1) For added data that is necessary to do this inspection, refer to the manuals that
follow:
− Nondestructive Test Manual (NDTM) Part 1−General Information 
− Structural Repair Manual (SRM)
− Aircraft Maintenance Manual (AMM).
 
                        certified to an NDT Standard approved by the National Airworthiness Authority.
C. Location
(1) The area is in Zone 311/312 (Refer to NDTM Part 1, 51−01−03).
D. Access
(1) Access to the engine support beam is from the aft−equipment compartment door
311BB.
E. Parts Examined in this Procedure
Refer to Table 1.
Table 1 − Part Identification Data
ITEM
NO. [1] DESCRIPTION DRAWING OR PARTNUMBER [2] MATERIAL SPECIFICATION
1 Top web 601−35006−3 7075−T62 QQ−A−250/132 Bottom web 601−35006−5 7075−T62 QQ−A−250/13
NOTE [1]: Parts that do not include an item number are not identified in Figure 3.
NOTE [2]: Numbers that do not include a dashed suffix are drawing numbers.
2. Effectivity
A. All aircraft Pre−SB 601R−53−059 Rev A or later,
or (Pre−SB 601R−53−065 and Pre−SB 601−53−068).
NOTE: Part 6, 53−61−110 must be accomplished in order to complete the full
inspection.
        
TR 53-
(2)    This inspection must be done by a Level II or Level III ultrasonic quali-fied individual
AWL 53-61-110
Page 2of 10
130
Sep 15/23

### Page 3

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−110
EFFECTIVITY: SEE PARAGRAPH 2
3. Tools and Equipment
A. Use the items identified as follows, or their equivalent (Refer to NDTM Part 1, 51−20−04):
NOTE: Equivalent ultrasonic equipment may be used provided that it satisfies the requirements of 
this procedure and is capable of resolving the reference notch in
the calibration reference standard at the required level of resolution. 
− Ultrasonic Flaw Detector,
Sonatest Model: UFDS
− Miniature angle−beam transducer, 45 degrees in Al, 0.25 X 0.375 in. (6.35 X 9.52 mm),
5 MHz frequency,
Model: VM 7−121−TC−A
− Coaxial cable (BNC to microdot)
− Gorptech industrial ultrasonic couplant gel supplied by Inspectech Ltd
−  MHI RJ Aviation calibration reference standard No. EXCM601R30039, similar and cross section as 
the inspection area containing electrical discharge machined (EDM) notches
− High intensity light source.
4. Preparation and Cleaning
A. Prepare the inspection area as follows:
(1) Identify the location of the area to be inspected.
WARNING: MAKE SURE THAT THERE IS A GOOD FLOW OF CLEAN AIR AND SUFFICIENT FIRE 
PROTECTION.  USE APPROVED BODY PROTECTION
WHEN YOU USE SOLVENTS.  ALL SOLVENTS ARE POISONOUS AND SOME ARE 
FLAMMABLE.
(2) Open the aft−equipment compartment door to get access to the engine support
beam (Refer to Part 1, 51−01−04).
(3) Clean the inspection surfaces (Refer to the SRM, 51−26−00).
NOTE: It is not necessary to remove the finish from the parts unless it shows
deterioration or local damage.
(4) If the finish in the area to be inspected is damaged or deteriorated, remove the finish
(Refer to the SRM, chapter 51).
5. Inspection for Subsurface Cracks Initiating from the Most Forward Row of Fasteners in the
0.032−in. (0.81 mm) Thick Section of the Top and Bottom Webs at FS625.30, at BL0.00 and
BL4.00, along WL119.12 and WL111.09
A. Equipment Calibration
Refer to Figure 1 and Figure 2.
(1) Connect the microminiature angle−beam transducer VM 7−121−TC−A to the
ultrasonic instrument using the coaxial cable.
(2) Turn the power ON and set the instrument to pulse−echo test mode and 5 MHz test
frequency.
        
TR 53-
of 10Page 3
130
Sep 15/23

### Page 4

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−110
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361110_003.dg, jp/gg, 11/09/00
0.62 in.
(15.75 mm)
0.62 in.
(15.75 mm)
NOTE
Letters A through D are EDM notches.
TRANSDUCER
PLACEMENT 1
TRANSDUCER
PLACEMENT 2
A
B
D
C
TRANSDUCER
PLACEMENT 3
TRANSDUCER
PLACEMENT 4
−4 ANGLE
−3 WEB
CALIBRATION REFERENCE STANDARD EXCM601R
30039
AND TRANSDUCER PLACEMENTS
CHEM MILL
LINE
(REF)
1.00 in.
(25.4 cm)
0.032 in.
(0.81 mm)
0.050 in.
(1.27 mm)
0.25 in.
(6.35 mm)
−4 ANGLE
−5 ANGLE
−3 WEB
(FOUR PLACES)
Calibration Reference Standard − Calibration and Inspection
Figure 1
        
TR 53-
of 10Page 4
130
Sep 15/23

### Page 5

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−110
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361110_004.dg, gg/jp, 01/11/00
NEB
NEA
IP
CRT DISPLAY
IP
EFH
IP NEC
TRANSDUCER PLACEMENT 3
50 1000
TRANSDUCER PLACEMENT 4
TRANSDUCER PLACEMENT 1 TRANSDUCER PLACEMENT 2
50 100
50 10050 1000 0
0
IP NED
NOTES
50
100
50
100
50
100SIGNAL AMPLITUDE
50
100
SIGNAL AMPLITUDE SIGNAL AMPLITUDE
SIGNAL AMPLITUDE
IP = Initial pulse.
EFH = echo from hole.
NEA = Echo from notch A.
NEB = Echo from notch B.
NEC = Echo from notch C.
NED = Echo from notch D.
CRT DISPLAY
CRT DISPLAY CRT DISPLAY
EFH
CRT Displays − Calibration and Indications
Figure 2
        
TR 53-
of 10Page 5
130
Sep 15/23

### Page 6

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−110
EFFECTIVITY: SEE PARAGRAPH 2
(3) Apply an even layer of couplant gel on the 0.032−in. (0.81 mm) thick section of −3
web adjacent to the −4 and −5 angles (0.62 in. (15.75 mm) edge distance side) of the 
calibration reference standard EXCM601R30039, as shown in Figure 1.
(4) Do the instrument calibration on the calibration reference standard as follows: 
(a) Position the front of the transducer against the −4 angle so that the sound
beam is directed at EDM notch A, see Transducer Placement 1, Figure 1. Swivel the 
transducer to obtain a maximized reflection signal from EDM notch A.
(b) Adjust the instrument (GAIN) control to obtain a 100% full screen height (FSH)
signal from EDM notch A.
(c) Use the instrument (DELAY) and (RANGE) controls to set the leading edge of
the reflection signal from EDM notch A at 20% of the horizontal limit on the baseline.
B. Inspection Procedure
Refer to Figure 2 and Figure 3.
(1) After equipment calibration as outlined in Paragraph 5.A., apply an even layer of couplant gel on 
the 0.32−in. (0.81 mm) thick sections of the top and bottom webs,
601−35006−3 and 601−35006−5 respectively, forward corner at BL0.00 and BL4.00 
adjacent to the edge of the transversal angles (with the vertical flange) at FS625.30. The 
couplant gel must cover approximately 0.50 in. (12.70 mm) each side of the
most forward row of fasteners.
(2) Position the transducer on the top web 601−35006−3 forward corner with its front against the 
transversal angle (the side with the vertical flange) at BL0.00.  Scan both
sides of the fastener with a slight swivel movement and use the edge of the transversal angle 
as a guide.
(3) Repeat Paragraph 5.B.(2) at BL4.00.
(4) Repeat Paragraph 5.B.(2) and 5.B.(3) for the bottom web 601−35006−5.
C. Acceptance or Rejection Criteria
(1) Any distinct indications with an amplitude signal of 50% FSH or greater is classified
as a crack and cause for rejection.
(2) Record and report results in accordance with company guidelines and policies.
(3) For indications that exceed the allowable limits, it is recommended that you contact
MHIRJ Customer Support (refer to SRM 51−13−01).
        
TR 53-
of 10Page 6
130
Sep 15/23

### Page 7

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−110
EFFECTIVITY: SEE PARAGRAPH 2
FS 625.30
BL 0.00
LBL 38.00
WL 119.12
WL 111.09
FS 625.30
rnd5361110_005.dg, gg, 14/09/00
RBL 38.00
NOTE
1 Examine the shaded area.
A
B
B
A
−B B
1
TRANSVERSAL
WL 119.12
WL 111.09
FS 625.30
TRANSVERSAL
(19 PLACES)
(19 PLACES)
LBL 36.20
LBL 27.50
LBL 18.00
LBL 4.00
RBL 18.00
RBL 4.00
RBL 9.50
RBL 27.50
RBL 36.20
LBL 9.50
(19 PLACES)
FS 640.00
(TYPICAL)
TOP WEB
1
2ND FORWARD
FASTENER
2ND FORWARD
FASTENER
MOST FORWARD
FASTENER
Inspection of the Engine Support Beam at FS625.30 Between RBL38.00 and LBL38.00 −
Location and Inspection
Figure 3
        
TR 53-
of 10Page 7
130
Sep 15/23

### Page 8

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−110
EFFECTIVITY: SEE PARAGRAPH 2
6. Inspection for Subsurface Cracks Initiating from the Second Forward Row of Fasteners in the
0.032−in. (0.81 mm) Thick Section of the Top and Bottom Webs at FS625.30, at 
BL0.00 and BL4.00, along WL119.12 and WL111.09
A. Equipment Calibration
Refer to Figure 1 and Figure 2.
(1) Do the instrument calibration on the calibration reference standard as follows: 
(a) Position the front of the transducer against the −4 angle so that the sound
beam is directed at EDM notch B, see Transducer Placement 2, Figure 1. Swivel the 
transducer to obtain a maximized reflection signal from EDM notch B.
(b) Adjust the instrument (GAIN) control to obtain a 100% full screen height (FSH)
signal from EDM notch B.
(c) Use the instrument (DELAY) and (RANGE) controls to set the leading edge of
the reflection signal from EDM notch B at 20% of the horizontal limit on the baseline.
B. Inspection Procedure
Refer to Figure 2 and Figure 3.
(1) After equipment calibration as outlined in Paragraph 6.A., apply an even layer of couplant gel on 
the 0.32−in. (0.81 mm) thick sections of the top and bottom webs,
601−35006−3 and 601−35006−5 respectively, forward corner at BL0.00 and BL4.00 
adjacent to the edge of the transversal angles (with the vertical flange) at FS625.30. The 
couplant gel must cover approximately 0.50 in. (12.70 mm) each side of the second forward 
row of fasteners.
(2) Position the transducer on the top web 601−35006−3 aft corner with its front against
the transversal angle (the side with the vertical flange) at BL0.00.  Scan both sides of the 
fastener with a slight swivel movement and use the edge of the transversal angle as a guide.
(3) Repeat Paragraph 6.B.(2) at BL4.00.
(4) Repeat Paragraph 6.B.(2) and 6.B.(3) for the bottom web 601−35006−5.
C. Acceptance or Rejection Criteria
(1) Any distinct indications with an amplitude signal of 50% FSH or greater is classified
as a crack and cause for rejection.
(2) Record and report results in accordance with company guidelines and policies.
(3) For indications that exceed the allowable limits, it is recommended that you contact
MHIRJ Customer Support (refer to SRM 51−13−01).
7. Inspection for Subsurface Cracks Initiating from the Most Forward Row of Fasteners in the
0.05−in. (1.27 mm) Thick Section of the Top and Bottom Webs at FS625.30, Between BL9.50
and BL38.00, along WL119.12 and WL111.09
A. Equipment Calibration
Refer to Figure 1 and Figure 2.
        
TR 53-
of 10Page 8
130
Sep 15/23

### Page 9

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−110
EFFECTIVITY: SEE PARAGRAPH 2
(1) Apply a thick even layer of couplant gel on the 0.05−in. (1.27 mm) thick section of 
the −3 web adjacent to the −4 and −5 angles (0.62 in. (15.75 mm) edge distance 
side) of the calibration reference standard EXCM601R30039, as shown in Figure 1
.
(2) Do the instrument calibration on the calibration reference standard as follows: 
(a) Position the front of the transducer against the −4 angle so that the sound
beam is directed at EDM notch C, see Transducer Placement 3, Figure 1. 
Swivel the transducer to obtain a maximized reflection signal from EDM notch 
C.
(b) Adjust the instrument (GAIN) control to obtain a 100% full screen height (FSH)
signal from EDM notch C.
(c) Use the instrument (DELAY) and (RANGE) controls to set the leading edge of
the reflection signal from EDM notch C at 20% of the horizontal limit on the baseline.
B. Inspection Procedure 
Refer to Figure 3.
(1) After equipment calibration as outlined in Paragraph 7.A., apply an even layer of couplant gel on 
the 0.05−in. (1.27 mm) thick section of the top and bottom webs,
601−35006−3 and 601−35006−5 respectively, forward corner between BL9.50 and BL38.00 
adjacent to the edge of the transversal angles (with the vertical flange) at 
FS625.30.  The couplant gel must cover approximately 0.50 in. (12.70 mm) each side of the 
most aft row of fasteners.
(2) Position the transducer on the top web 601−35006−3 forward corner with its front against the 
transversal angle (the side with the vertical flange) at BL9.50.  Scan both
sides of the fastener with a slight swivel movement and use the edge of the transversal angle 
as a guide.
(3) Repeat Paragraph 7.B.(2) between BL9.50 and BL38.00.
(4) Repeat Paragraph 7.B.(2) and 7.B.(3) for the bottom web 601−35006−5.
C. Acceptance or Rejection Criteria
(1) Any distinct indications with an amplitude signal of 50% FSH or greater is classified
as a crack and cause for rejection.
(2) Record and report results in accordance with company guidelines and policies.
(3) For indications that exceed the allowable limits, it is recommended that you contact
MHIRJ Customer Support (refer to SRM 51−13−01).
8. Inspection for Subsurface Cracks Initiating from the Second Forward Row of Fasteners in the
0.05−in. (1.27 mm) Thick Sections of the Top and Bottom Webs at FS625.30, Between BL9.50 and BL38
.00, along WL119.12 and WL111.09
A. Equipment Calibration
Refer to Figure 1 and Figure 2.
(1) Apply an even layer of couplant gel on the 0.05−in. (1.27 mm) thick section of the 
−3 web adjacent to the −4 and −5 angles (0.62 in. (15.75 mm) edge distance side)
of the calibration reference standard EXCM601R30039, as shown in Figure 1.
        
TR 53-
of 10Page 9
130
Sep 15/23

### Page 10

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−110
EFFECTIVITY: SEE PARAGRAPH 2
(2) Do the instrument calibration on the calibration reference standard as follows: 
(a) Position the front of the transducer against the −4 angle so that the sound
beam is directed at EDM notch D, see Transducer Placement 4, Figure 1. Swivel the 
transducer to obtain a maximized reflection signal from EDM notch D.
(b) Adjust the instrument (GAIN) control to obtain a 100% full screen height (FSH)
signal from EDM notch D.
(c) Use the instrument (DELAY) and (RANGE) controls to set the leading edge of
the reflection signal from EDM notch D at 20% of the horizontal limit on the baseline.
B. Inspection Procedure 
Refer to Figure 3.
(1) After equipment calibration as outlined in Paragraph 8.A., apply an even layer of couplant gel on 
the 0.05−in. (1.27 mm) thick section of the top and bottom webs,
601−35006−3 and 601−35006−5 respectively, forward corner between BL9.50 and BL38.00 
adjacent to the edge of the transversal angles (with the vertical flange) at 
FS625.30.  The couplant gel must cover approximately 0.50 in. (12.70 mm) each side of the 
second forward row of fasteners.
(2) Position the transducer on the top web 601−35006−3 forward corner with its front against the 
transversal angle (the side with the vertical flange) at BL9.50.  Scan both
sides of the fastener with a slight swivel movement and use the edge of the transversal angle 
as a guide.
(3) Repeat Paragraph 8.B.(2) between BL9.50 and BL38.00.
(4) Repeat Paragraph 8.B.(2) and 8.B.(3) for the bottom web 601−35006−5.
C. Acceptance or Rejection Criteria
(1) Any distinct indications with an amplitude signal of 50% FSH or greater is classified
as a crack and cause for rejection.
(2) Record and report results in accordance with company guidelines and policies.
(3) For indications that exceed the allowable limits, it is recommended that you contact
MHIRJ Customer Support (refer to SRM 51−13−01).
9. Close Out
A. Remove the couplant gel from the inspection surfaces.
B. Make sure that NDTM Part 6, 53−61−110 has been completed.
C. If the finish in the inspection area was removed, replace the finish (Refer to the SRM,
Chapter 51).
D. Remove all tools, equipment and unwanted materials from the work area.
E. Close the aft−equipment compartment door (Refer to Part 1, 51−01−04).
        
TR 53-
of 10Page 10
130
Sep 15/23

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.