### Page 1

NONDESTRUCTIVE TESTING MANUAL
Part 4 -  Ultrasonic
Part 4
Part 5
Part 6
Part 7
Part 8
Part 9
53- 61- 152
EFFECTIVITY: SEE PARAGRAPH 2 TR 53- 132
TEMPORARY REVISION 53 - 132
FILING INSTRUCTIONS: Insert this Temporary Revision facing TASK Part 4, 53- 61- 152.
Record the incorporation of this Temporary Revision on the yellow
RECORD OF TEMPORARY REVISIONS sheet at the front of this
volume.
Keep this Temporary Revision until Revision 45 incorporates this
information into the Nondestructive Testing Manual.
DESCRIPTION: This Temporary Revision revises TASK Part 4, 53- 61- 152
ALTERNATE MEANS OF COMPLIANCE (AMOC) TO AD
CF- 2001- 26R1 (SERVICE BULLETIN 601R- 53- 071), INSPECTION
OF THE UPPER AND LOWER WEBS AND DOUBLERS, AND AFT
WEB OF THE REPAIR ENGINE SUPPORT BEAM AT FS640.00 to
introduce a new calibration reference standard (CRS) and make other
miscellaneous changes.
Part 4Page 1 of 23
Sep 15/23

### Page 2

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
ALTERNATIVE MEANS OF COMPLIANCE (AMOC) TO AD CF−2001−26R1 (SERVICE BULLETIN
601R−53−071), INSPECTION OF THE UPPER AND LOWER WEBS AND DOUBLERS, AND AFT
WEB OF THE REPAIR ENGINE SUPPORT BEAM AT FS640.00
1. General
A. Function
(1) This inspection procedure is used to detect subsurface cracks in the engine support
beam (ESB) at the following locations:
NOTE: The expected crack propagation is in the forward−to−aft direction at the
top and bottom surfaces and in the up−to−down (vertical) direction on the
side surfaces of the ESB.
− First outer forward row of fastener holes in the upper and lower webs covered by
the inner rib flanges, along WL119.09 and WL111.12 at BL18.00 and BL0.00 at
FS640.00
− First outer forward and aft (along FS640.00) rows of fastener holes in the upper
and lower doublers or splice angles − horizontal flange covered by the external
longitudinal stiffeners, along WL119.12 and WL111.09 at BL31.41 (upper doubler
angle only), BL27.50, BL22.30, BL18.00, BL13.30, BL9.50, BL4.28, and BL0.00 at
FS640.00.
− Lower row of fastener holes in the aft web at the upper doubler angle − vertical
flange covered by the inner ribs at BL18.00 and BL0.00 at FS640.00
− Upper row of fastener holes in the aft web at the lower doubler − vertical flange
covered by the inner ribs at BL18.00 and BL0.00 at FS640.00
− Upper and lower rows of fastener holes in the upper doubler − vertical flange
covered by the external vertical stiffeners at BL27.50 and BL9.50 at FS640.00
− Upper and lower rows of fastener holes in the lower doubler − vertical flange
covered by the external vertical stiffeners at BL27.50 and BL9.50 at FS640.00
− Upper and lower webs of the first two forward fasteners covered by the
transversal angles along WL119.12 and WL111.09 between LBL38.00 and
RBL38.00 at FS625.30.
NOTE: The inspection applies to both sides of the aircraft.
(2) The inspection procedure is applicable to aircraft with the post modifications listed in
Table 1.
Table 1 − Aircraft Post Modification Configurations  
MODIFICATION
SUMMARY/REO KIT DRAWING/CONDITION REFER TOFIGURE NO.
TC601R16420 K601R35011 for Aircraft already repaired perREO 601R−53−61−345 Figure 2
TC601R16486 K601R35012 Figure 3
REO 601R−53−61−870 Replaces REO 601R−53−61−345 Figure 4
        
TR 53- 132
AWL 53-61-152
Page 2 of 23
Sep 15/23

### Page 3

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
B. Reference Information
For additional data that is necessary to do this inspection, refer to the manuals that follow:
− Nondestructive Testing Manual (NDTM), Part 1−General Information 
− Structural Repair Manual (SRM)
− Aircraft Maintenance Manual (AMM).
This inspection must be done by a Level II or Level III ultrasonic qualified individual certified to 
an NDT Standard approved by the National Airworthiness Authority.
C. Location
The engine support beam is located in Zone 310 (Refer to NDTM Part 1, 51−01−03).
D. Access
(1) Access to the inspection area is through the aft−equipment compartment door
311BB (Refer to Part 1, 51−01−04).
(2) It is recommended that the auxiliary power unit (APU) and the complete APU
enclosure be removed to gain access to the engine support beam.
E. Parts Examined in This Procedure
For aircraft repaired per TC601R16420 or kit K601R35011, refer to Table 2.
For aircraft repaired per TC601R16486 or kit K601R35012, refer to Table 3.
For aircraft repaired per REO 601R−53−61−870, refer to Table 4.
Table 2 − Part Identification Data for Aircraft Post TC601R16420 (Kit Drawing K601R35011)
 
ITEM
NO. [1] DESCRIPTION DRAWING OR PARTNUMBER [2] MATERIAL SPECIFICATION
1 Upper web 601−35006−3 7075−T62 Al AlloyAlcd Sheet QQ−A−250/13
2 Upper doubler 601R−53−61−345−1 2024−T42 Al Alloy QQ−A−250/53 Lower doubler 601R−53−61−345−6 ySheet QQ−A−250/5
4 Lower web 601−35006−5 7075−T62 Al AlloyAlcd Sheet QQ−A−250/13
NOTE [1]: Parts that do not include an item number are not identified in Figure 2.
NOTE [2]: Numbers that do not include a dashed suffix are drawing numbers.
        
TR 53- 132
Page 3 of 23
Sep 15/23

### Page 4

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
Table 2 − Part Identification Data for Aircraft Post TC601R16420 (Kit Drawing K601R35011)
− (Continued)
ITEM
NO. [1] SPECIFICATIONMATERIALDRAWING OR PARTNUMBER [2]DESCRIPTION
5 Aft web 601−35006−9
6 Upper splice 601R350112−1
Upper splice 601R350112−2
7 Upper doubler 601R350111−1
2024 T42 Al AlloyUpper doubler 601R350111−2 2024−T42 Al AlloySheet QQ−A−250/5
8 Lower doubler 601R350113−1
Sheet
Lower doubler 601R350113−2
9 Lower splice 601R350114−1
Lower splice 601R350114−2
NOTE [1]: Parts that do not include an item number are not identified in Figure 2.
NOTE [2]: Numbers that do not include a dashed suffix are drawing numbers.
Table 3 − Part Identification Data for Aircraft Post TC601R16486 (Kit Drawing K601R35012)
 
ITEM
NO. [1] DESCRIPTION DRAWING OR PARTNUMBER [2] MATERIAL SPECIFICATION
1 Upper web 601−35006−3 7075−T62 Al AlloyAlcd Sheet QQ−A−250/13
2 Upper doubler 601R350115−1 2024−T42 Al AlloySheet QQ−A−250/5
3 Lower doubler 601R350116−1 2024−T42 Al AlloySheet QQ−A−250/5
4 Lower web 601−35006−5 7075−T62 Al AlloyAlcd Sheet QQ−A−250/13
5 Aft web 601−35006−9 2024−T42 Al AlloySheet QQ−A−250/5
NOTE [1]: Parts that do not include an item number are not identified in Figure 3
NOTE [2]: Numbers that do not include a dashed suffix are drawing numbers.
Table 4 − Part Identification Data for Aircraft with REO 601R53−61−870 Incorporated
 
ITEM
NO. [1] DESCRIPTION DRAWING OR PARTNUMBER [2] MATERIAL SPECIFICATION
1 Upper web 601−35006−3 7075−T62 Al AlloyAlcd Sheet QQ−A−250/13
2 Upper doubler 601R−53−61−870−1 2024−T42 Al AlloySheet QQ−A−250/5
        
TR 53- 132
Page 4 of 23
Sep 15/23

### Page 5

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
Table 4 − Part Identification Data for Aircraft with REO 601R53−61−870 Incorporated
− (Continued)
ITEM
NO. [1] SPECIFICATIONMATERIALDRAWING OR PARTNUMBER [2]DESCRIPTION
3 Lower doubler 601R−53−61−870−6 2024−T42 Al AlloySheet QQ−A−250/5
4 Lower web 601−35006−5 7075−T62 Al AlloyAlcd Sheet QQ−A−250/13
5 Aft web 601−35006−9 2024−T42 Al AlloySheet QQ−A−250/5
NOTE [1]: Parts that do not include an item number are not identified in Figure 4.
NOTE [2]: Numbers that do not include a dashed suffix are drawing numbers.
2. Effectivity
All aircraft post TC601R16420 (kit drawing K601R35011). TC601R16486 (kit drawing
K601R35012), or REO 601R−53−61−870.
NOTE: NDTM Part 6, 53−61−152 and NDTM Part 9, 53−61−152 must be accomplished in
order to complete the full inspection.
3. Tools and Equipment
Use the items identified as follows, or their equivalent (Refer to NDTM Part 1, 51−20−04):
NOTE: Equivalent ultrasonic equipment may be used provided that it satisfies the 
requirements of this procedure and is capable of resolving the reference notch in the
calibration standard at the required level of resolution. 
− Ultrasonic Flaw Detector
Sonatest Model: UFDS
− Miniature angle beam transducer, 5.0 MHz frequency, 45 degrees refractive angle in
aluminum, contact surface 0.250 in. (6.35 mm) by 0.375 in. (9.52 mm) 
VM Products Model: VM 7−121
− Coaxial cable (BNC to microdot)
− Inspectech LTD Gorptech Industrial Ultrasonic Couplant Gel
− MHI RJ Aviation calibration reference standard No. EXCM601R30039, containing electrical
discharge machined (EDM) notches 
− High intensity light source.
4. Preparation and Cleaning
A. Prepare the inspection area as follows:
(1) Identify the location of the area to be inspected.
(2) Open the aft−equipment compartment door 311BB to get access to the engine
support beam (Refer to the AMM, 06−42−00−00).
        
TR 53- 132
Page 5 of 23
Sep 15/23

### Page 6

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
(3) Remove the APU and the complete APU enclosure (Refer to the AMM,
49−11−01−000−801).
WARNING: MAKE SURE THAT THERE IS A GOOD FLOW OF CLEAN AIR AND
SUFFICIENT FIRE PROTECTION.  USE APPROVED BODY PROTECTION
WHEN YOU USE SOLVENTS.  ALL SOLVENTS ARE POISONOUS AND
SOME ARE FLAMMABLE.
(4) Clean the inspection surfaces (Refer to the SRM, 51−26−00).
NOTE: It is not necessary to remove the finish from the parts unless they show
deterioration or local damage.
(5) If the finish in the area to be inspected is damaged or deteriorated, remove the finish,
complete the inspection, and then replace the finish (refer to the SRM, Chapter 51).
NOTE: It is not necessary to remove the finish from the parts unless it shows
deterioration or local damage.
(6) If the finish in the area to be inspected is damaged or deteriorated, remove the finish
(Refer to the SRM, chapter 51).
        
TR 53- 132
Page 6 of 23
Sep 15/23

### Page 7

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
5. Inspection for Subsurface Cracks Initiating From the First Outer Row of Fasteners of the
Repair in the 0.032−in (0.81−mm) Thick Section of the Upper and Lower Webs Along
WL119.12 and WL111.09 at BL0.00, FS640.00 and Inspection of the First Two Forward
Fasteners Aft of FS625.30 at BL0.00 and BL4.28
A. Equipment Calibration
Refer to Figure 1.
(1) Calibrate the ultrasonic equipment as follows:
(a) Connect the transducer (VM 7−121) to the ultrasonic instrument with the
coaxial cable.
(b) Turn the power ON and set the instrument to pulse−echo test mode and 5 MHz
test frequency.
(c) Apply an even layer of couplant gel on the 0.032−in (0.813−mm) thick section
of the −3 web adjacent to the −4 and −5 angles (0.62−in (15.75−mm) edge 
distance side) of reference standard EXCM601R30039.
(d) Do the instrument calibration on the reference standard as follows:
1 Place the front of the transducer against the −4 angle so that the sound
beam is directed at EDM notch A (Notch Echo A (NEA)) (Refer to 
Transducer Placement 1 in Figure 1).  Manipulate the transducer by 
swiveling the transducer toward and away from the NEA to obtain a 
maximized amplitude signal.
2 Adjust the instrument GAIN control to obtain a 100% full screen height
(FSH) signal from NEA.
3 Use the instrument DELAY and RANGE controls to set the leading edge of
the reflection signal from NEA at 20% of the horizontal limit on the baseline.
        
TR 53- 132
Page 7 of 23
Sep 15/23

### Page 8

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361152_027.dg, lr, 01/11/05
0.62 in.
(15.75 mm)
0.62 in.
(15.75 mm)
TRANSDUCER
PLACEMENT 1
A
B
TRANSDUCER
PLACEMENT 2
−3 WEB
CHEM MILL
LINE
(REF)
0.050 in.
(1.27 mm)
0.25 in.
(6.35 mm)
−4 ANGLE
−5 ANGLE
−3 WEB
EDM NOTCH
NEA
CRT DISPLAY
IP
EFH
IP
NEB
TRANSDUCER PLACEMENT 2
50 1000
TRANSDUCER PLACEMENT 1
50 1000
NOTES
50
100
SIGNAL AMPLITUDE
50
100
SIGNAL AMPLITUDE
IP = Initial pulse.
NEA = Notch echo from
EDM notch A.
CRT DISPLAY
0.032 in.
(0.81 mm)
(4 PLACES)
NEB = Notch echo from
EDM notch B.
EFH = Echo from
fastener hole.
Calibration Reference Standard EXCM601R30039 and Transducer Placement, and CRT Dis-
plays of Calibration Notch Signals
Figure 1
        
TR 53- 132
Page 8 of 23
Sep 15/23

### Page 9

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2B
. Inspection Procedure
Refer to Figure 1 and Figure 2, Figure 3, or Figure 4.
NOTE: For parts to be examined, refer to Table 2, Table 3, or Table 4.
The numbers in the brackets [  ] correspond to the item numbers found in
Figure 2, Figure 3, and Figure 4 as well as Table 2, Table 3, and Table 4.
A nonrelevant indication from the fastener hole may or may not appear when the 
sound beam is in−line with the center of the fastener, but the indication will 
always appear closer to the initial pulse or left side of the CRT screen than a 
relevant discontinuity indication.
(1) Inspect the first outer forward row of fasteners under the repair doublers [2] and [3]
(for K601R35012 and REO 601R53−61−870) and [2], [3], [8], and [9] (for 
K601R35011) in the 0.032−in (0.81−mm) thick section of the upper web [1] and 
lower web [4] along WL119.12 and WL111.09 at BL0.00 as follows:
NOTE: There are a total of two fastener locations symbolized as that require
inspection.  One is located at the lower web and one is located at the 
upper web.  Refer to Sheets 1 and 2 of Figure 2, Figure 3, or Figure 4. 
Inspection of the upper and lower webs under the repair doublers are 
performed internally via the lightening holes in the aft web.
(a) After calibration as outlined in paragraph 5.A., apply an even layer of couplant
gel on the 0.032−in (0.81−mm) thick section of the upper web [1] and lower 
web [4] adjacent to the edge of the upper and lower rib flanges of the first 
forward outer row of fasteners at BL0.00, approximately at FS633.00.
(b) Couple the transducer to the upper web [1] with the front of the transducer 
against the rib flange at BL0.00.  Scan both sides of the forward outer fastener
with a slight swivel movement towards and away from the fastener. 
NOTE: Use the edge of the rib flange as a transducer guide.
(c) Repeat step 5.B.(1)(b) for the fastener identified with the symbol on the lower
web [4]at BL0.00.
(d) Note all relevant indications 50% FSH or greater and its location on the part.
NOTE: Ensure the indication is not from the fastener hole.
(2) Inspect the first two forward fasteners of the upper web [1] and lower web [4] aft of
FS625.30 along BL0.00 and BL4.28 as follows:
NOTE: There are a total of 12 fastener locations symbolized as that require
inspection.  The lower web has 6 of the fasteners (2 fasteners each at 
BL0.00, LBL4.28, and RBL4.28).  The other 6 fasteners are on the upper 
web (2 fasteners each at BL0.00, LBL4.28, and RBL4.28).  Refer to Sheets 
1 and 2 of Figure 2, Figure 3, or Figure 4 for the modification configuration 
applicable to the aircraft to be inspected.
Inspection of the upper and lower webs for the two forward fasteners aft of 
FS625.30 are performed externally.
(a) After calibration as outlined in paragraph 5.A., apply an even layer of couplant
gel on the 0.032−in (0.81−mm) thick section of the upper web [1] and lower 
web [4] adjacent to the edge of the upper and lower longitudinal stiffener angle 
flanges of the first two forward fasteners along BL0.00, LBL4.28 and RBL4.28, 
aft of FS625.30.
        
TR 53- 132
Page 9 of 23
Sep 15/23

### Page 10

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361152_005.dg, lr, 02/11/05
VIEW LOOKING DOWN
ON TOP SURFACE OF ENGINE SUPPORT BEAM
INSPECTSYMBOL
LEGEND
6. Upper splice.
7. Upper doubler.
Inspect upper web via lightening holes in
the aft web both sides of these fasteners.
Inspect upper doubler and/or splice angle
Inspect upper web externally both sides
Inspect upper doubler or splice (horizontal
flange) externally both sides of these
LBL36.20 LBL9.50 BL0.00
LBL4.28LBL31.41
LBL27.50
LBL22.30
LBL18.00
LBL13.30
FS
625.30
FS
640.00
0.063 in. (1.60 mm)
THICKNESS
SECTION OF WEB
CHEM MILL
LINE
(REF)
0.050 in. (1.27 mm)
THICKNESS
SECTION OF WEB 0.032 in. (0.81 mm)THICKNESS
SECTION OF WEB
CHEM MILL
LINE
(REF)
1
7
1. Upper web.
2. Upper doubler (existing
6 2
(horizontal flange) externally both sides of
A
of these fasteners.
GREO 601R−53−61−345−1).
A
TYPICAL TRANSDUCER
PLACEMENT AND MOVEMENT
BOTH SIDES OF FASTENER
TO BE INSPECTED
TRANSDUCER
these fasteners.
fasteners.
Inspection Locations of the Engine Support Beam for Aircraft Post TC601R16420 (Repair Kit
K601R35011)
Figure 2 (Sheet 1)
        
TR 53- 132
Page 10 of 23
Sep 15/23

### Page 11

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
VIEW LOOKING UP
ON LOWER WEB OF ENGINE SUPPORT BEAM
LEGEND
8. Lower doubler.
3. Lower doubler (existing
LBL18.00 LBL9.50 BL0.00LBL13.30 LBL4.28
FS
625.30
FS
640.00
LBL27.50 LBL22.30
INSPECTSYMBOL
Inspect lower web via lightening holes in
the aft web both sides of these fasteners.
Inspect lower doubler (horizontal flange)
Inspect lower web externally both sides
0.032 in. (0.81 mm)
THICKNESS
SECTION OF WEB
0.050 in. (1.27 mm)
THICKNESS
SECTION OF WEB
4
9
0.063 in. (1.60 mm)
THICKNESS
SECTION OF WEB
rnd5361152_007.dg, lr, 02/11/05
8
4. Lower web.
9. Lower splice.
3
Inspect lower doubler or splice (horizontal
flange) externally both sides of these
GREO 601R−53−61−345−6).
of these fasteners.
externally both sides of these fasteners.
B
TYPICAL TRANSDUCER
PLACEMENT AND MOVEMENT
BOTH SIDES OF FASTENER
TO BE INSPECTED
TRANSDUCER
B
fasteners.
Inspection Locations of the Engine Support Beam for Aircraft Post TC601R16420 (Repair Kit
K601R35011)
Figure 2 (Sheet 2)
        
TR 53- 132
Page 11 of 23
Sep 15/23

### Page 12

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361152_006.dg, lr, 02/11/05
INSPECTSYMBOL
Inspect aft web (covered by inner ribs) via lightening
holes in the aft web both sides of these fasteners.
Inspect lower doubler angle (vertical flange)
Inspect upper doubler angle (vertical flange)
LEGEND
2. Upper doubler (existing
REO 601R−53−61−345−1).
7. Upper doubler.
LBL36.20
LBL31.41
LBL27.50
LBL22.30
LBL18.00
LBL13.30
LBL9.50
LBL4.28
BL0.00
WL
119.12
WL
111.09
2
9
6
58
8. Lower doubler.
3. Lower doubler (existing
9. Lower splice.
6. Upper splice.
7
3
externally both sides of these fasteners.
externally both sides of these fasteners.
5. Aft web.
REO 601R−53−61−345−6).
C
TYPICAL TRANSDUCER
PLACEMENT AND MOVEMENT
BOTH SIDES OF FASTENER
TO BE INSPECTED
TRANSDUCER
C
VIEW LOOKING FORWARD
AT FS640.00 ON AFT WEB
Inspection Locations of the Engine Support Beam for Aircraft Post TC601R16420 (Repair Kit
K601R35011)
Figure 2 (Sheet 3)
        
TR 53- 132
Page 12 of 23
Sep 15/23

### Page 13

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361152_010.dg, lr, 02/11/05
INSPECTSYMBOL
LEGEND
Inspect upper web via lightening holes in the
aft web both sides of these fasteners.
Inspect upper doubler angle (horizontal flange)
Inspect upper web externally both sides of
Inspect upper doubler angle (horizontal flange)
externally both sides of these fasteners.
1. Upper web.
2. Upper doubler.
externally both sides of these fasteners.
these fasteners.
A
TYPICAL TRANSDUCER
PLACEMENT AND MOVEMENT
BOTH SIDES OF FASTENER
TO BE INSPECTED
VIEW LOOKING DOWN
ON TOP SURFACE OF ENGINE SUPPORT BEAM
LBL36.20 LBL9.50 BL0.00
LBL4.28LBL31.41
LBL27.50
LBL22.30
LBL18.00
LBL13.30
FS
625.30
FS
640.00
0.063 in. (1.60 mm)
THICKNESS
SECTION OF WEB CHEM MILL
LINE
(REF)
0.050 in. (1.27 mm)
THICKNESS
SECTION OF WEB
0.032 in. (0.81 mm)
THICKNESS
SECTION OF WEB CHEM MILLLINE
(REF)
1
2
A
TRANSDUCER
Inspection Locations of the Engine Support Beam for Aircraft Post TC601R16486 (Repair Kit
K601R35012)
Figure 3 (Sheet 1)
        
TR 53- 132
Page 13 of 23
Sep 15/23

### Page 14

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
VIEW LOOKING UP
ON LOWER WEB OF ENGINE SUPPORT BEAM
LEGEND
3. Lower doubler.
4. Lower web.
LBL18.00 LBL9.50 BL0.00LBL13.30 LBL4.28
FS
625.30
FS
640.00
LBL27.50 LBL22.30
INSPECTSYMBOL
Inspect lower web via lightening holes in the
aft web both sides of these fasteners.
Inspect lower doubler angle (horizontal flange)
Inspect lower web externally both sides of these
0.032 in. (0.81 mm)
THICKNESS
SECTION OF WEB
0.050 in. (1.27 mm)
THICKNESS
SECTION OF WEB
4
0.063 in. (1.60 mm)
THICKNESS
SECTION OF WEB
rnd5361152_011.dg, lr, 02/11/05
3
Inspect lower doubler angle (horizontal flange)
externally both sides of these fasteners.
fasteners.
externally both sides of these fasteners. B
TYPICAL TRANSDUCER
PLACEMENT AND MOVEMENT
BOTH SIDES OF FASTENER
TO BE INSPECTED
B
TRANSDUCER
Inspection Locations of the Engine Support Beam for Aircraft Post TC601R16486 (Repair Kit
K601R35012)
Figure 3 (Sheet 2)
        
TR 53- 132
Page 14 of 23
Sep 15/23

### Page 15

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361152_004.dg, yf/lr, 02/11/05
VIEW LOOKING FORWARD
AT FS640.00 ON AFT WEB
INSPECTSYMBOL
Inspect aft web (covered by inner ribs) via lightening
holes in the aft web both sides of these fasteners.
Inspect lower doubler angle (vertical flange)
Inspect upper doubler angle (vertical flange)
LEGEND
2. Upper doubler.
4. Lower doubler.
LBL36.20
LBL31.41
LBL27.50
LBL22.30
LBL18.00
LBL13.30
LBL9.50
LBL4.28
BL0.00
WL
119.12
WL
111.09
2
5 4
externally both sides of these fasteners.
externally both sides of these fasteners.
5. Aft web.
C
TYPICAL TRANSDUCER
PLACEMENT AND MOVEMENT
BOTH SIDES OF FASTENER
TO BE INSPECTED
C
TRANSDUCER
Inspection Locations of the Engine Support Beam for Aircraft Post TC601R16486 (Repair Kit
K601R35012)
Figure 3 (Sheet 3)
        
TR 53- 132
Page 15 of 23
Sep 15/23

### Page 16

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361152_002.dg, yf/lr, 02/11/05
INSPECTSYMBOL
LEGEND
Inspect upper web via lightening holes in the
aft web both sides of these fasteners.
Inspect upper doubler angle (horizontal flange)
Inspect upper web externally both sides of
Inspect upper doubler angle (horizontal flange)
externally both sides of these fasteners.
1. Upper web.
2. Upper doubler.
externally both sides of these fasteners.
these fasteners.
A
TYPICAL TRANSDUCER
PLACEMENT AND MOVEMENT
BOTH SIDES OF FASTENER
TO BE INSPECTED
VIEW LOOKING DOWN
ON TOP SURFACE OF ENGINE SUPPORT BEAM
LBL36.20 LBL9.50 BL0.00
LBL4.28LBL31.41
LBL27.50
LBL22.30
LBL18.00
LBL13.30
FS
625.30
FS
640.00
0.063 in. (1.60 mm)
THICKNESS
SECTION OF WEB CHEM MILL
LINE
(REF)
0.050 in. (1.27 mm)
THICKNESS
SECTION OF WEB
0.032 in. (0.81 mm)
THICKNESS
SECTION OF WEB CHEM MILLLINE
(REF)
1
2
A
TRANSDUCER
Inspection Locations of the Engine Support Beam for Aircraft with REO601R53−61−870
Incorporated
Figure 4 (Sheet 1)
        
TR 53- 132
Page 16 of 23
Sep 15/23

### Page 17

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
VIEW LOOKING UP
ON LOWER WEB OF ENGINE SUPPORT BEAM
LEGEND
3. Lower doubler.
4. Lower web.
LBL18.00 LBL9.50 BL0.00LBL13.30 LBL4.28
FS
625.30
FS
640.00
LBL27.50 LBL22.30
INSPECTSYMBOL
Inspect lower web via lightening holes in the
aft web both sides of these fasteners.
Inspect lower doubler angle (horizontal flange)
Inspect lower web externally both sides of these
0.032 in. (0.81 mm)
THICKNESS
SECTION OF WEB
0.050 in. (1.27 mm)
THICKNESS
SECTION OF WEB
4
0.063 in. (1.60 mm)
THICKNESS
SECTION OF WEB
rnd5361152_003.dg, yf/lr, 02/11/05
3
Inspect lower doubler angle (horizontal flange)
externally both sides of these fasteners.
fasteners.
externally both sides of these fasteners. B
TYPICAL TRANSDUCER
PLACEMENT AND MOVEMENT
BOTH SIDES OF FASTENER
TO BE INSPECTED
B
TRANSDUCER
Inspection Locations of the Engine Support Beam for Aircraft with REO601R53−61−870
Incorporated
Figure 4 (Sheet 2)
        
TR 53- 132
Page 17 of 23
Sep 15/23

### Page 18

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361152_012.dg, lr, 02/11/05
VIEW LOOKING FORWARD
AT FS640.00 ON AFT WEB
INSPECTSYMBOL
Inspect aft web (covered by inner ribs) via lightening
holes in the aft web both sides of these fasteners.
Inspect lower doubler angle (vertical flange)
Inspect upper doubler angle (vertical flange)
LEGEND
2. Upper doubler.
3. Lower doubler.
LBL36.20
LBL31.41
LBL27.50
LBL22.30
LBL18.00
LBL13.30
LBL9.50
LBL4.28
BL0.00
WL
119.12
WL
111.09
2
5 3
externally both sides of these fasteners.
externally both sides of these fasteners
5. Aft web.
C
TYPICAL TRANSDUCER
PLACEMENT AND MOVEMENT
BOTH SIDES OF FASTENER
TO BE INSPECTED
C
TRANSDUCER
Inspection Locations of the Engine Support Beam for Aircraft with REO601R53−61−870
Incorporated
Figure 4 (Sheet 3)
        
TR 53- 132
Page 18 of 23
Sep 15/23

### Page 19

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
(b) Couple the transducer to the upper web [1] with the front of the transducer 
against the edge of the angle flange at BL0.00.  Scan both sides of the forward
outer fastener with a slight swivel movement toward and away from the 
fasteners.
NOTE: Use the edge of the rib flange as a transducer guide.
(c) Repeat step 5.B.(2)(b) for the second fastener aft of FS625.30 represented by
the  symbol on the upper web [1] at BL0.00.
(d) Repeat step 5.B.(2)(b) for the two fasteners aft of FS625.30 represented by the
 symbol on the upper web [1] at LBL4.28 and RBL4.28.
(e) Repeat step 5.B.(2)(b) for the two fasteners aft of FS625.30 represented by the
 symbol on the lower web [4] at BL0.00, LBL4.28, and RBL4.28.
(f) Note all relevant indications 50% FSH or greater and its location on the part.
NOTE: Ensure the indication is not from the fastener hole.
C. Acceptance or Rejection Criteria
(1) Any distinct indication with an amplitude signal of 50% FSH or greater is classified as
a crack and cause for rejection.
(2) Record and report results in accordance with company guidelines and policies.
(3) For indications that exceed the allowable limits, it is recommended that you contact
MHIRJ Customer Support (refer to SRM 51−13−01).
6. Inspection Under the Repair for Subsurface Cracks Initiating From Fastener Holes on the
Upper and Lower Webs (at BL18.00), on the Upper and Lower Doublers and/or Splice Angles
(at BL0.00, BL4.28, BL9.50, BL13.30, BL18.00, BL22.30, BL27.50, BL31.41) Forward of
FS640.00 and the Aft Web at BL0.00 and BL18.00 at FS640.00, and Inspection of the Upper
and Lower Webs at BL9.50, BL13.30, BL18.00, BL22.30, BL27.50, BL31.41, and BL36.20 at the
First Two Fasteners Aft of FS625.30
A. Equipment Calibration
Refer to Figure 1.
(1) Calibrate the ultrasonic equipment as follows:
(a) Apply an even layer of couplant gel on the 0.050−in (1.27−mm) thick section 
of the −3 web adjacent to the −4 and −5 angles (0.620−in (15.75−mm) edge
distance side) of reference standard EXCM601R30039.
(b) Do the instrument calibration on the reference standard as follows:
1 Place the front of the transducer against the −4 angle so that the sound
beam is directed at EDM notch B (Notch Echo B (NEB)) (Refer to 
Transducer Placement 2 in Figure 1).  Manipulate the transducer by 
swiveling the transducer toward and away from NEB to obtain a maximized 
amplitude signal.
2 Adjust the GAIN to obtain a 100% FSH signal from NEB.
3 Use the DELAY and RANGE controls to set the leading edge of the
reflection signal from NEB at 20% of the horizontal limit on the baseline.
        
TR 53- 132
Page 19 of 23
Sep 15/23

### Page 20

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
B. Inspection Procedure
Refer to Figure 1 and Figure 2, Figure 3, or Figure 4.
NOTE: For parts to be examined, refer to Table 2, Table 3, or Table 4.
The numbers in the brackets [  ] correspond to the item numbers found in
Figure 2, Figure 3, and Figure 4 as well as Table 2, Table 3, and Table 4.
The upper, lower, and aft web inspections under the repair doubler are
performed internally via the lightening holes and access holes in the aft web at
FS640.00.
The upper and lower doublers and/or splice angle inspections are performed
externally.
The upper and lower web inspections for the two forward fasteners aft of
FS625.30 and forward of FS640.00 (unaffected by modifications) are performed
externally.
A nonrelevant indication from the fastener hole may or may not appear when the
sound beam is in−line with the center of the fastener, but the indication will
always appear closer to the initial pulse or left side of the CRT screen than a
relevant discontinuity indication.
(1) Inspect the upper web [1], lower web [4], and aft web [5] under repair doubler [2],
[3], [7], and [8] angles as follows:
NOTE: There are a total of four fastener locations on the upper and lower webs
identified with the symbol  that require inspection.  Two of them are at the
lower web (at LBL18.00 and RBL18.00) and two at the upper web (at
LBL18.00 and RBL18.00.  Refer to Sheets 1 and 2 of Figure 2, Figure 3, or
Figure 4.
There are a total of six fastener locations on the aft web identified with the
symbol  that require inspection.  Two each are located at LBL18.00,
BL0.00, and RBL18.00.  Refer to Sheet 3 of Figure 2, Figure 3, or Figure 4.
Access to the upper and lower webs and aft web surfaces is via the
lightening holes and access holes in the aft web.
(a) After calibration as outlined in paragraph 6.A., apply an even layer of couplant
gel on the upper web [1], lower web [4], and aft web [5] adjacent to the edge
of the rib flange for the fasteners to be inspected at BL18.00 and for the aft web
[5] at BL18.00 and BL0.00, under the repair forward from FS640.00.
(b) Couple the transducer to the upper web [1] with the front of the transducer
against the edge of the rib horizontal flange at BL18.00, with the sound beam
directed toward the fastener to be inspected.  Scan both sides of the fastener
with a slight swivel movement toward and away from the fastener. Refer to
Sheet 1 of Figure 2, Figure 3, or Figure 4.
NOTE: Use the edge of the rib as a transducer guide.
(c) Couple the transducer to the lower web [4] with the front of the transducer
against the edge of the rib horizontal flange at BL18.00, with the sound beam
directed toward the fastener to be inspected.  Scan both sides of the fastener
with a slight swivel movement toward and away from the fastener.  Refer to
Sheet 2 of Figure 2, Figure 3, or Figure 4.
NOTE: Use the edge of the rib as a transducer guide.
        
TR 53- 132
Page 20 of 23
Sep 15/23

### Page 21

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
(d) Couple the transducer to the aft web [5] upper corner, lower fastener with the 
front of the transducer against the edge of the rib vertical flange at BL0.00, with
the sound beam directed toward the fastener to be inspected.  Scan both sides 
of the fastener with a slight swivel movement toward and away from the 
fastener.  Refer to Sheet 3 of Figure 2, Figure 3, or Figure 4.
NOTE: Use the edge of the rib as a transducer guide.
(e) Repeat step 6.B.(1)(d) for the aft web [5] lower corner at BL0.00, upper
fastener.
(f) Repeat step 6.B.(1)(d) for the aft web [5] upper corner at BL18.00, lower
fastener.
(g) Repeat step 6.B.(1)(d) for the aft web [5] lower corner at BL18.00, upper
fastener.
(h) Note all relevant indications 50% FSH or greater and its location on the part.
NOTE: Ensure the indication is not from the fastener hole.
(2) Inspect the horizontal and vertical flanges of the repair upper doublers [2] and [7],
lower doublers [3] and [8], and splice angles [6] and [9] (for K601R35011) and 
inspect the upper doubler [2] and lower doubler [3] (for K601R35012 and REO 
601R53−61−870) as follows:
NOTE: Access to the inspection area of the upper and lower doublers or splice
angles is from the exterior of the ESB.
(a) After calibration as outlined in paragraph 6.A., apply an even layer of couplant
gel on the areas that follow:
− The horizontal flanges of the upper doublers [2] and [7] and upper splice
angle [6] adjacent to the edge of the upper longitudinal stiffeners at the
outer aft and forward rows of fasteners identified with the symbols  and
(for K601R35011) or the upper doubler [2] (for K601R35012 or REO 
601R53−61−870) at BL31.41, BL27.50, BL22.30, BL18.00, BL13.30, BL9.50, 
BL4.28, and BL0.00 (Refer to Sheet 1 of Figure 2, Figure 3, or Figure 4)
− The horizontal flanges of the lower doublers [3] and [8] and lower splice 
angle [9] adjacent to the edge of the lower longitudinal stiffeners at the outer
aft and forward row of fasteners identified with the symbols  and  (for 
K601R35011) or the lower doubler [3] (for K601R35012 and REO 
601R53−61−870) at BL27.50, BL22.30, BL18.00, BL13.30, BL9.50, BL4.28, 
and BL0.00 (Refer to Sheet 2 of Figure 2, Figure 3, or Figure 4).
− The vertical flanges of the upper doublers [2], [7] adjacent to the vertical 
stiffener flange fasteners identified with the symbol  (for K601R35011) or
the upper doubler [2] (for K601R35012 and REO 601R53−61−870) at 
BL27.50 and BL9.50 (Refer to Sheet 3 of Figure 2, Figure 3, or Figure 4).
− The vertical flanges of the lower doublers [3] and [8] adjacent to the vertical
stiffener flange fasteners identified with the symbol  (for K601R35011) or 
the upper doubler [2] (for K601R35012 and REO 601R53−61−870) at 
BL27.50 and BL9.50 (Refer to Sheet 3 of Figure 2, Figure 3, or Figure 4).
        
TR 53- 132
Page 21 of 23
Sep 15/23

### Page 22

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2(b) 
Couple the transducer to the upper doubler [2] horizontal flange with the front
of the transducer against the edge of the longitudinal stiffener at BL31.41. 
Scan both sides of the outer forward fastener with a slight swivel movement 
toward and away from the fastener.
NOTE: Use the edge of the stiffener as a transducer guide.
(c) Repeat step 6.B.(2)(b) for the outer aft fastener at BL31.41.
(d) Repeat steps 6.B.(2)(b) and 6.B.(2)(c) on the upper doubler [2] and [7] and
upper splice angle [6] horizontal flanges (for K601R35011) or the upper doubler 
[2] (for K601R35012 and REO 601R53−61−870) at BL27.50, BL22.30, BL18.00, 
BL13.30, BL9.50, BL4.28, and BL0.00.
(e) Repeat steps 6.B.(2)(b) and 6.B.(2)(c) on the lower doublers [3] and [8] and
lower splice angle [9] horizontal flange(s) (for K601R35011) or the lower 
doubler [3] (for K601R35012 and REO 601R53−61−870) at BL27.50, BL22.30, 
BL18.00, BL13.30, BL9.50, BL4.28, and BL0.00.
(f) Repeat steps 6.B.(2)(b) and 6.B.(2)(c) for the upper doublers [2], [7] vertical 
flanges (for K601R35011) or the upper doubler [2] (for K601R35012 and REO
601R53−61−870) at BL27.50 and BL9.50.
(g) Repeat steps 6.B.(2)(b) and 6.B.(2)(c) for the lower doublers [3] and [8] vertical
flanges (for K601R35011) or the upper doubler [2] (for K601R35012 and REO 
601R53−61−870) at BL27.50 and BL9.50.
(h) Note all relevant indications 50% FSH or greater and its location on the part.
NOTE: Ensure the indication is not from the fastener hole.
(3) Inspect the upper web [1] and lower web [4] at the first two fasteners aft of FS625.30
between LBL36.21 and RBL36.21 as follows:
(a) After calibration as outlined in paragraph 6.A., apply an even layer of couplant
gel on the upper web’s [1] and lower web’s [4] outer surface adjacent to the 
edge of upper longitudinal stiffeners at the first two fasteners aft of FS625.30 
identified with the symbols  (upper surface) and  (lower surface) at BL36.20,
BL31.41, BL27.50, BL22.30, BL18.00, BL13.30, and BL9.50.
(b) Couple the transducer to the upper web [1] with the front of the transducer
against the edge of the longitudinal stiffener at BL36.20.  Scan both sides of the 
forward fastener with a slight swivel movement toward and away from the 
fastener.
NOTE: Use the edge of the stiffener as a transducer guide.
(c) Repeat step 6.B.(3)(b) for the aft fastener at BL36.20.
(d) Repeat step 6.B.(3)(b) and 6.B.(3)(c) for the forward and aft fasteners at
BL31.41, BL27.50, BL22.30, BL18.00, BL13.30, and BL9.50.
(e) Couple the transducer to the lower web [4] with the front of the transducer
against the edge of the longitudinal stiffener at BL36.20.  Scan both sides of the 
forward fastener with a slight swivel movement toward and away from the 
fastener.
NOTE: Use the edge of the stiffener as a transducer guide.
(f) Repeat step 6.B.(3)(b) for the aft fastener at BL36.20.
        
TR 53- 132
Page 22 of 23
Sep 15/23

### Page 23

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−152
EFFECTIVITY: SEE PARAGRAPH 2
(g) Repeat step 6.B.(3)(b) and 6.B.(3)(c) for the forward and aft fasteners at
BL31.41, BL27.50, BL22.30, BL18.00, BL13.30, and BL9.50.
(h) Note all relevant indications 50% FSH or greater and its location on the part.
NOTE: Ensure the indication is not from the fastener hole.
C. Acceptance or Rejection Criteria
(1) Any distinct indication with an amplitude signal of 50% FSH or greater is classified as
a crack and cause for rejection.
(2) Record and report results in accordance with company guidelines and policies.
(3) For indications that exceed the allowable limits, it is recommended that you contact
MHIRJ Customer Support (refer to SRM 51−13−01).
7. Close Out
A. Remove ultrasonic couplant from the inspection surfaces.
B. Make sure that NDTM Part 6, 53−61−152 and NDTM Part 9, 53−61−152 have been
completed.
C. If the finish in the inspection area was removed, replace the finish (refer to the SRM,
Chapter 51).
D. Install the APU and the complete APU enclosure (Refer to the AMM,
49−11−01−400−801).
E. Remove all tools, equipment, and unwanted materials from the work area.
F . Close the aft−equipment compartment door 311BB (Refer to the AMM, 06−42−00−00).
        
TR 53- 132
Page 23 of 23
Sep 15/23

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.