### Page 1

NONDESTRUCTIVE TESTING MANUAL
Part 4 -  Ultrasonic
Part 4
Part 5
Part 6
Part 7
Part 8
Part 9
Page 1
53- 61- 149
EFFECTIVITY: SEE PARAGRAPH 2 TR 53- 133
TEMPORARY REVISION 53- 133
FILING INSTRUCTIONS: Insert this Temporary Revision facing TASK Part 4, 53- 61- 149.
Record the incorporation of this Temporary Revision on the yellow
RECORD OF TEMPORARY REVISIONS sheet at the front of this
volume.
Keep this Temporary Revision until Revision 45 incorporates this
information into the Nondestructive Testing Manual.
DESCRIPTION: This Temporary Revision revises TASK Part 4, 53- 61- 149 SPECIAL
DETAILED INSPECTION OF THE ENGINE SUPPORT BEAM,
FS640.00 CAP ANGLES, PREVENTATIVE OR REPAIR
MODIFICATIONS to introduce a new calibration reference standard
(CRS) and make other miscellaneous changes.
Part 4
of 12
Sep 15/23

### Page 2

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−149
EFFECTIVITY: SEE PARAGRAPH 2
SPECIAL DETAILED INSPECTION OF THE ENGINE SUPPORT BEAM, FS640.00 CAP ANGLES,
PREVENTATIVE OR REPAIR MODIFICATIONS
AWL 53−61−149
1. General
A. The nondestructive testing procedure that follows is for the inspection of the engine
support beam for subsurface cracks in the forward to aft direction on the upper and lower
surfaces, and in the vertical direction on the aft surfaces at the locations that follow:
− The upper, lower, and the aft webs, and the upper and the lower doublers at FS640.00
between WL111.09 and WL119.12 from BL0.00 to LBL36.20.
B. This inspection must be done by a Level II or Level III ultrasonic qualified individual
certified to an NDT Standard approved by the National Airworthiness Authority.
C. This procedure is applicable to the left side and the right side. The procedure for the left
side is given. The right side is identical as the left side.
2. Effectivity
A. All aircraft Post−SB 601R−53−068 Part B.
3. Job Set−Up Information
A. Tools and EquipmentR
EFERENCE DESIGNATION
Epoch lll Model 2300 Ultrasonic Flaw Detector with an A−Scan presentation
(Parametrics or equivalent)
XA−455T Miniature angle beam transducer, 45 degrees refracted
angle in Aluminum, 5.0 MHz, 0.375 in. (9.52 mm) high 
x 0.375 in. (9.52 mm) length x 0.260 in. (6.60 mm) 
width; Side Microdot Connector (TechnaNDT or 
equivalent)
EXCM601R30039 Calibration reference standard containing electrical
discharge machined notch, (MHI RJ Aviation ULC) 
Commercially available Coaxial cable (BNC to microdot)
Commercially available Explosion proof light
NOTE: If equivalent equipment is used, it must satisfy the requirements of the task and
resolve the electrical discharge machined (EDM) notches of the calibration 
reference standard (CRS) at the required level of resolution and sensitivity.
B. Consumable Materials
REFERENCE DESIGNATION
05−178 Ultrasonic Couplant Gel (Sonotech)
        
TR 53- 133
Page 2of 12
Sep 15/23

### Page 3

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−149
EFFECTIVITY: SEE PARAGRAPH 2
C. Parts
ITEM DESCRIPTION DRAWING NUMBER MATERIAL
1 Upper Web 601−35006 7075−T62 AL ALY
2 Lower Web 601−35006 7075−T62 AL ALY
3 Aft Web 601−35006 2024−T42 AL ALY
4 Upper Doubler 601R350115 2024−T42 AL ALY
5 Lower Doubler 601R350116 2024−T42 AL ALY
D. Reference Information
MANUAL NO REFERENCE DESIGNATION
CSP A−010 TASK 51−20−04 (Part 1) Ultrasonic − InspectionProcedures
CSP A−001 AMM 49−11−01−000−801 Removal of the APU EnclosureAssembly
CSP A−001 AMM 49−11−01−400−801 Installation of the APU EnclosureAssembly
E. Standard Practices Information
MANUAL NO REFERENCE DESIGNATION
CSP A−001 AMM 51−25−56−390−802 Water−DisplacingCorrosion−Inhibiting Compound
CSP A−008 SRM 51−13−01 Defect and Damage RepairRequests − Report Procedure
CSP A−008 SRM 51−26−00 Cleaning
4. Job Set−Up
A. Obey all the ultrasonic inspection procedures (TASK 51−20−04 (Part 1)).
B. Open the access door that follows:
ACCESS DESIGNATION
311BB Aft equipment compartment door
C. If necessary, remove the APU enclosure assembly (AMM 49−11−01−000−801).
D. Make sure that the inspection area is clean.
E. If necessary, remove the water−displacing corrosion−inhibiting compound (CIC) with a
lint−free cloth and solvent (SRM 51−26−00).
F . If the finish in the inspection area is damaged or deteriorated, remove the finish.
5. Procedure
A. Do the special detailed inspection for subsurface cracks on the FS640.00 cap angles,
preventive or repair modifications as follows:
        
TR 53- 133
Page 3of 12
Sep 15/23

### Page 4

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−149
EFFECTIVITY: SEE PARAGRAPH 2Refer to Figure 1 and Figure 2.
(1) Calibrate the equipment as follows:
(a) Connect the transducer with the coaxial cable to the ultrasonic instrument. 
(b) Turn the instrument ON.
(c) Adjust and set the instrument controls to the calibration data settings for the
CRS EXCM601R30039 at Transducer Position (TP1).
(d) Apply a thin even layer of couplant gel on the −3 web adjacent to the EDM
notch A on the 0.620 in. (15.75 mm) angle edge distance side of CRS 
EXCM601R30039 at Transducer Position (TP1).
(e) Put the transducer on the −3 web adjacent to the −4 angle and the sound
beam pointed at the EDM notch A.
(f) Move the transducer to and away with a slight swivel to get the maximum signal
from the EDM notch A.
(g) Adjust the GAIN control to get 80% full screen height (FSH) signal from the
EDM notch A.
(h) Adjust the RANGE and DELAY controls to set the leading edge of the reflection
signal from EDM notch A at 2.6 on the horizontal time baseline.
(2) Examine the upper web (1) and the horizontal flange of the upper doubler (4) as
follows:
Refer to Figure 3 (Sheet 2).
NOTE: The inspection of the upper web is done internally through the cut out
holes in the aft web.
NOTE: A non−relevant indication from the fastener hole can show when the
sound beam is aligned with the center of the fastener. The indication will 
show nearer to the initial pulse or left side of the screen than a discontinuity 
indication.
(a) Apply a thin even layer of couplant gel on the upper web (1) and the horizontal
flange of the upper doubler (4), adjacent to the fastener identified for 
inspection.
(b) Position the transducer adjacent to the initial fastener of the upper web (1) with
the front of the transducer against the edge of the rib flange at BL0.00.
(c) Scan forward and aft of the fastener with a small swivel movement towards and
away from the fastener.
NOTE: Use the edge of the rib as a probe guide.
(d) Repeat the inspection of the upper web (1) for the fastener at BL18.00.
(e) Repeat the inspection for the horizontal flange of the upper doubler (4) for all
the fasteners identified for inspection.
(3) Examine the lower web (2) and the horizontal flange of the lower doubler (5) as
follows:
        
TR 53- 133
Page 4of 12
Sep 15/23

### Page 5

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−149
EFFECTIVITY: SEE PARAGRAPH 2R
efer to Figure 3 (Sheet 3).
NOTE: The inspection of the lower web is done internally through the cut out holes
in the aft web.
NOTE: A non−relevant indication from the fastener hole can show when the
sound beam is aligned with the center of the fastener. The indication will 
show nearer to the initial pulse or left side of the screen than a discontinuity 
indication.
(a) Apply a thin even layer of couplant gel on the lower web (2) and the horizontal 
flange of the lower doubler (5), adjacent to the fastener identified for inspection.
(b) Position the transducer adjacent to the initial fastener of the lower web (2) with
the front of the transducer against the edge of the rib flange at BL0.00
(c) Scan forward and aft of the fastener with a small swivel movement towards and
away from the fastener.
NOTE: Use the edge of the rib as a probe guide.
(d) Repeat the inspection of the lower web (2) for the fastener at BL18.00.
(e) Repeat the inspection for the horizontal flange of the lower doubler (5) for all
the fasteners identified for inspection.
(4) Examine the aft web (3) and the vertical flanges of the upper doubler (4) and the
lower doubler (5) as follows:
Refer to Figure 3 (Sheet 4).
NOTE: The inspection of the aft web is done internally through the cut out holes in
the aft web.
NOTE: A non−relevant indication from the fastener hole can show when the
sound beam is aligned with the center of the fastener. The indication will 
show nearer to the initial pulse or left side of the screen than a discontinuity 
indication.
(a) Apply a thin even layer of couplant gel on the aft web (3) and the vertical 
flanges of the upper doubler (4) and the lower doubler (5), adjacent to the
fastener identified for inspection at FS640.00.
(b) Position the transducer adjacent to the initial fastener of the aft web (3) with the
front of the transducer against the edge of the rib flange at BL0.00.
(c) Scan top and bottom of the fastener with a small swivel movement towards and
away from the fastener.
NOTE: Use the edge of the rib as a probe guide.
(d) Repeat the inspection of the aft web (3) for the remaining fastener at BL0.00
and BL18.00 at FS640.00.
(e) Repeat the inspection for the vertical flanges of the upper doubler (4) and the
lower doubler (5) for all the fasteners identified for inspection at FS640.00. 
(5) Do the indication evaluation as follows:
(a) Record all the indications of 40% FSH or greater.
(b) Compare the horizontal time baseline position of the indication with the
horizontal time baseline position of the EDM notch signal on the CRS.
        
TR 53- 133
Page 5of 12
Sep 15/23

### Page 6

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−149
EFFECTIVITY: SEE PARAGRAPH 2(
c) Make sure that the indication is not from:
− the fastener hole bore
− an accumulation of couplant in front of the transducer 
− any other non−relevant factors.
(6) Do the acceptance and rejection criterias as follows:
(a) Any relevant indication with an amplitude signal of 40% FSH or more is
classified as a crack and is cause for rejection.
(7) If necessary, send a defect and damage report to MHI RJ Group (SRM 51−13−01).
6. Close Out:
A. Clean the ultrasonic couplant gel from the inspection surface (SRM 51−26−00).
B. If the finish in the inspection area was removed, replace the finish.
C. If necessary, apply water−displacing corrosion−inhibiting compound (CIC) to the
applicable surfaces.
D. Remove all tools, equipment and unwanted materials from the work area.
E. If removed, install the APU enclosure assembly (49−11−01−400−801).
F . Close the access door that follows:
ACCESS DESIGNATION
311BB Aft equipment compartment door
        
TR 53- 133
Page 6of 12
Sep 15/23

### Page 7

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−149
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361149_006.dg, hg, jun24/2014
SCREEN DISPLAYINSTRUMENT SETTINGS
FREQUENCY      5 MHz
GAIN                    40.0 dB
RANGE                5.0 in.
REJECT               0%
THICKNESS         0
PULSER               High
DAMPING            400 ohms
WAVEFORM        Fullwave
100%
50%
80%
FSH
0
VELOCITY
ANGLE
DELAY/ZERO
0.1232 in./  S
45  AL
0   S
FASTENER HOLE
SIGNAL EDM NOTCHA SIGNALINITIALPULSE (IP)
123456789 1 0
Calibration Data and Instrument Settings for CRS EXCM601R30039. 
Figure 1
        
TR 53- 133
Page 7of 12
Sep 15/23

### Page 8

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−149
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361149_007.dg, kp, Jan. 27, 2015
0.250 in.
(6.35 mm)
EDM NOTCH
(4 PLACES)
0.620 in.
(15.75 mm)
EDM NOTCH A
CHEM MILL
LINE
(REF)
TRANSDUCER POSITION 1
(TP1)
−3 WEB0.050 in.
(1.27 mm)
0.032 in.
(0.81 mm)
−4 ANGLE
−5 ANGLE A
A A A
Calibration Reference Standard EXCM601R30039 and Transducer Posi-
tion Figure 2
        
TR 53- 133
Page 8of 12
Sep 15/23

### Page 9

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−149
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361149_008.dg, hg, jun24/2014
FS640.00
FS625.30
FS640.00
WL111.09
WL119.12
LBL
38.00
BL
0.00
RBL
38.00
Special Detailed Inspection of the Engine Support Beam, FS640.00 Cap Angles, Preventative or
Repair Modification − Inspection/Check
Figure 3 (Sheet 1 of 4)
        
TR 53- 133
Page 9of 12
Sep 15/23

### Page 10

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−149
EFFECTIVITY: SEE PARAGRAPH 2
1. Upper web.
4. Upper doubler.
LEGEND
Indicate scan areas
Indicate inspection areas
Indicate transducer positions,
beam direction and movement
rnd5361149_009.dg, kp, Jan. 27, 2015
VIEW LKG DOWN
ON UPPER WEB OF ENGINE SUPPORT BEAM
FS640.00
FS625.30
LBL36.20
LBL31.41
LBL27.50
LBL22.30
LBL18.00
LBL13.30
LBL9.50
LBL4.28
BL0.00
1
4
SYMBOL INSPECT
Examine the upper web internally through cut−outs in the aft web and
the horizontal flange of the upper doubler externally both sides of these
fasteners.
Examine the horizontal flange of the upper doubler externally both
sides of these fasteners.
TYPICAL TRANSDUCER PLACEMENT AND MOVEMENT
BOTH SIDES OF FASTENERS TO BE INSPECTED
TRANSDUCER
Special Detailed Inspection of the Engine Support Beam, FS640.00 Cap Angles, Preventative or
Repair Modification − Inspection/Check
Figure 3 (Sheet 2 of 4)
        
TR 53- 133
Page 10of 12
Sep 15/23

### Page 11

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−149
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361149_010.dg, kp, Jan. 27, 2015
FS640.00
FS625.30
LBL27.50 LBL22.30 LBL18.00 LBL13.30 LBL9.50 LBL4.28 BL0.00
VIEW LKG UP
ON LOWER WEB OF ENGINE SUPPORT BEAM
2
5
SYMBOL INSPECT
Examine the lower web internally through cut−outs in the aft web and
the horizontal flange of the lower doubler externally both sides of these
fasteners.
Examine the horizontal flange of the lower doubler externally both
sides of these fasteners.
2. Lower web.
5. Lower doubler.
LEGEND
Indicate scan areas
Indicate inspection areas
Indicate transducer positions,
beam direction and movement
TYPICAL TRANSDUCER PLACEMENT AND MOVEMENT
BOTH SIDES OF FASTENERS TO BE INSPECTED
TRANSDUCER
Special Detailed Inspection of the Engine Support Beam, FS640.00 Cap Angles, Preventative or
Repair Modification − Inspection/Check
Figure 3 (Sheet 3 of 4)
        
TR 53- 133
Page 11of 12
Sep 15/23

### Page 12

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−149
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361149_011.dg, hg, jun24/2014
LBL36.20
LBL31.41
LBL27.50
LBL22.30
LBL18.00 LBL13.30
LBL9.50
LBL4.28
BL0.00
3. Aft Web.
4. Upper doubler.
5. Lower doubler.
LEGEND
Indicate scan areas
Indicate inspection areas
Indicate transducer positions,
beam direction and movement
VIEW LKG FWD
ON AFT WEB OF ENGINE SUPPORT BEAM AT FS640.00
5
3
4
SYMBOL INSPECT
Examine the aft web internally through cut−outs in aft web both sides of
these fasteners.
Examine the vertical flanges of upper and lower doublers externally
both sides of these fasteners.
WL119.12
WL111.09
TYPICAL TRANSDUCER PLACEMENT AND MOVEMENT
BOTH SIDES OF FASTENERS TO BE INSPECTED
TRANSDUCER
Special Detailed Inspection of the Engine Support Beam, FS640.00 Cap Angles, Preventative or
Repair Modification − Inspection/Check
Figure 3 (Sheet 4 of 4)
        
TR 53- 133
Page 12 of 12
Sep 15/23

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.