Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

NONDESTRUCTIVE TESTING MANUAL
Part 4 -  Ultrasonic
Part 4
Part 5
Part 6
Part 7
Part 8
Part 9
Page 1
53- 61- 114
EFFECTIVITY: SEE PARAGRAPH 2 TR 53- 135
TEMPORARY REVISION 53- 135
FILING INSTRUCTIONS: Insert this Temporary Revision facing TASK Part 4, 53- 61- 114.
Record the incorporation of this Temporary Revision on the yellow
RECORD OF TEMPORARY REVISIONS sheet at the front of this
volume.
Keep this Temporary Revision until Revision 45 incorporates this
information into the Nondestructive Testing Manual.
DESCRIPTION: This Temporary Revision revises TASK Part 4, 53- 61- 114 SPECIAL
DETAILED INSPECTION OF THE ENGINE SUPPORT BEAM AT
FS640.0 BETWEEN LBL18.0 AND RBL18.0 to introduce a new
calibration reference standard (CRS) and make other miscellaneous
changes.
Part 4
of 10
Sep 15/23

### Page 2

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−114
EFFECTIVITY: SEE PARAGRAPH 2
SPECIAL DETAILED INSPECTION OF THE ENGINE SUPPORT BEAM AT FS640.0 BETWEEN
LBL18.0 AND RBL18.0,
1. General
A. Function
(1) This inspection procedure is used to detect subsurface cracks propagating from the two aft
rows of fastener holes in the top and bottom webs, 601−35006−3 and 
601−35006−5 respectively, of the engine support beam covered by the transversal angles,
along WL119.12 and WL111.09, and between LBL18.00 and RBL18.00, at FS640.00. 
NOTE: This subsurface inspection is to be done at the same time as the eddy
current inspection (Refer to the NDTM Part 6, 53−61−114). 
This inspection procedure applies to both sides of the aircraft.
B. Reference Information
(1) For added data that is necessary to do this inspection, refer to the manuals that
           follow:
− Nondestructive Testing Manual (NDTM) Part 1 General Information 
− Structural Repair Manual (SRM)
− Aircraft Maintenance Manual (AMM).
                               certified to an NDT Standard approved by the National Airworthiness Authority.
C. Location
(1) The area is in Zone 311/312 (Refer to the NDTM Part 1 General Information,
51−01−03).
D. Access
(1) The access to the engine support beam is from the aft−equipment compartment 
door 311BB.
E. Parts Examined in this Procedure
Refer to Table 1.
Table 1 − Part Identification Data
ITE M
NO. [1] DESCRIPTION DRAWING OR PARTNUMBER [2] MATERIAL SPECIFICATION
1 Top web 601−35006−3 7075−T62 QQ−A−250/132 Bottom web 601−35006−5 7075−T62 QQ−A−250/13
NOTE [1]: Parts that do not include an item number are not identified in Figure 3.
NOTE [2]: Numbers that do not include a dashed suffix are drawing numbers.
2. Effectivity
A. All aircraft Pre−SB 601R−53−059 Rev. A or later,
or Pre−SB 601R−53−065.
NOTE: NDTM Part 6, 53−61−114 must be accomplished in order to complete the full
inspection.
        
TR 53- 135
AWL 53-61-114
(2) This inspection must be done by a Level II or Level III ultrasonic qualified indivual
Page 2of 10
Sep 15/23

### Page 3

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−114
EFFECTIVITY: SEE PARAGRAPH 23. 
Tools and Equipment
A. Use the items identified as follows, or their equivalent (refer to NDTM Part 1, General
Information, 51−20−04):
NOTE: Equivalent ultrasonic equipment may be used provided that it satisfies the
requirements of this procedure and is capable of resolving the reference notch in 
the calibration reference standard at the required level of resolution.
− Ultrasonic Flaw Detector,
Sonatest Model: UFDS
− Miniature angle−beam transducer, 45 degrees in Al, 0.25 X 0.375 in. (6.35 X 9.52 mm),
5 MHz frequency,
Model: VM 7−121−TC−A
− Coaxial cable (BNC to microdot)
− Gorptech industrial ultrasonic couplant gel supplied by Inspectech Ltd
− MHI RJ Aviation calibration reference standard No. EXCM601R30039, similar in cross
section as the inspection area containing electrical discharge machined (EDM) notches 
− High intensity light source.
4. Preparation and Cleaning
A. Procedure
(1) Identify the location of the area to be inspected.
WARNING: MAKE SURE THAT THERE IS A GOOD FLOW OF CLEAN AIR AND
SUFFICIENT FIRE PROTECTION.  USE APPROVED BODY PROTECTION
WHEN YOU USE SOLVENTS.  ALL SOLVENTS ARE POISONOUS AND
SOME ARE FLAMMABLE.
(2) Open the aft−equipment compartment door to get access to the engine support
beam (Refer to NDTM Part 1, 51−01−04).
(3) Clean the inspection surfaces (Refer to the SRM, 51−26−00).
NOTE: It is not necessary to remove the finish from the parts unless it shows
deterioration or local damage.
(4) If the finish in the area to be inspected is damaged or deteriorated, remove the finish
(Refer to the SRM, chapter 51).
5. Inspection for Subsurface Cracks Initiating from the Most Aft Row of Fasteners in the
0.032−Inch (0.81 mm) Thick Section of the Top and Bottom Webs at FS640.00, at BL0.00 and
BL4.00, along WL119.12 and WL111.09
A. Equipment Calibration
Refer to Figure 1 and Figure 2.
        
TR 53- 135
Page 3of 10
Sep 15/23

### Page 4

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−114
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361114_003.dg, jp/gg, 11/09/00
0.62 in.
(15.75 mm)
NOTE
Letters A through D are EDM notches.
TRANSDUCER
PLACEMENT 1
TRANSDUCER
PLACEMENT 2
−5 ANGLE
A
B
D
C
TRANSDUCER
PLACEMENT 3
TRANSDUCER
PLACEMENT 4
−4 ANGLE
−4 ANGLE
CALIBRATION REFERENCE STANDARD EXCM601R
30039
AND TRANSDUCER PLACEMENTS
CHEM MILL
LINE
(REF)
1.00 in.
(25.4 cm)
0.032 in.
(0.81 mm)
0.050 in.
(1.27 mm)
0.25 in.
(6.35 mm)
−3 WEB
0.62 in.
(15.75 mm)
−3 WEB
(FOUR PLACES)
Calibration Reference Standard − Calibration and Inspection
Figure 1
        
TR 53- 135
Page 4of 10
Sep 15/23

### Page 5

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−114
EFFECTIVITY: SEE PARAGRAPH 2
rnd5361114_004.dg, gg/jp, 01/11/00
NEB
NEA
IP
CRT DISPLAY
IP EFH
IP NEC
TRANSDUCER PLACEMENT 3
50 1000
TRANSDUCER PLACEMENT 4
TRANSDUCER PLACEMENT 1 TRANSDUCER PLACEMENT 2
50 100
50 10050 1000 0
0
IP NED
NOTES
50
100
50
100
50
100SIGNAL AMPLITUDE
50
100
SIGNAL AMPLITUDE SIGNAL AMPLITUDE
SIGNAL AMPLITUDE
IP = Initial pulse.
EFH = echo from hole.
NEA = Echo from notch A.
NEB = Echo from notch B.
NEC = Echo from notch C.
NED = Echo from notch D.
CRT DISPLAY
CRT DISPLAY CRT DISPLAY
EFH
CRT Displays − Calibration and Indications
Figure 2
        
TR 53- 135
Page 5of 10
Sep 15/23

### Page 6

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−114
EFFECTIVITY: SEE PARAGRAPH 2
(1) Connect the microminiature angle−beam transducer VM 7−121−TC−A to the
ultrasonic instrument using the coaxial cable.
(2) Turn the power ON and set the instrument to pulse−echo test mode and 5 MHz test
frequency.
(3) Apply an even layer of couplant gel on the 0.032−inch (0.81 mm) thick section of
−3 web adjacent to the −4 and −5 angles (0.62−inch (15.75 mm) edge distance 
side) of the calibration reference standard EXCM601R30039, as shown in Figure 
1.
(4) Do the instrument calibration on the calibration reference standard as follows: 
(a) Position the front of the transducer against the −4 angle so that the sound
beam is directed at EDM notch A, see Transducer Placement 1, Figure 1. 
Swivel the transducer to obtain a maximized reflection signal form EDM notch 
A.
(b) Adjust the instrument (GAIN) control to obtain a 100% full screen height (FSH)
signal from EDM notch A.
(c) Use the instrument (DELAY) and (RANGE) controls to set the leading edge of
the reflection signal from EDM notch A at 20% of the horizontal limit on the 
baseline.
B. Inspection Procedure
Refer to Figure 2 and Figure 3.
(1) After equipment calibration as outlined in Paragraph 5.A., apply an even layer of
couplant gel on the 0.32−inch (0.81 mm) thick sections of the top and bottom webs,
601−35006−3 and 601−35006−5 respectively, aft corner at BL0.00 and BL4.00
adjacent to the edge of the transversal angles (with the vertical flange) at FS640.00.
The couplant gel must cover approximately 0.50 in. (12.70 mm) each side of the
most aft row of fasteners.
(2) Position the transducer on the top web 601−35006−3 aft corner with its front against
the transversal angle (the side with the vertical flange) at BL0.00.  Scan both sides of
the fastener with a slight swivel movement and use the edge of the transversal angle
as a guide.
(3) Repeat Paragraph 5.B.(2) at BL4.00.
(4) Repeat Para. 5.B.(2) and 5.B.(3) for the bottom web 601−35006−5.
C. Acceptance or Rejection Criteria
(1) Any distinct vertical deflection signal, which is 50% or greater than the response from
the 0.040−inch (1.00 mm) deep EDM notch, is classified as a crack indication. 
(2) Record and report results in accordance with company guidelines and policies.
(3) For indications that exceed the allowable limits, it is recommended that you contact
MHIRJ Customer Support (refer to SRM 51−13−01).
        
TR 53 - 135
Page 6of 10
Sep 15/23

### Page 7

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−114
EFFECTIVITY: SEE PARAGRAPH 2
FS 625.30
BL 0.00
WL 119.12
WL 111.09
FS 640.00
rnd5361114_005.dg, gg, 14/09/00
NOTE
1 Examine the shaded area.
A
B
A
1
TRANSVERSAL
(9 PLACES)
TRANSVERSAL
(9 PLACES)
(9 PLACES)
LBL 4.00
RBL 4.00
RBL 9.50
TOP WEB
1
FS 640.00
LBL 9.50
BOTTOM WEB
2
− BB
TOP WEB
1
1
BOTTOM WEB
2
WL 119.12
WL 111.09
FS 640.00
LBL 18.00
RBL 18.00
B
MOST AFT
FASTENER
2ND AFT
FASTENER
2ND AFT
FASTENER
Inspection of the Engine Support Beam at FS640.00 Between RBL18.00 and LBL18.00 −
Location and Inspection
Figure 3
        
TR 53- 135
Page 7of 10
Sep 15/23

### Page 8

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−114
EFFECTIVITY: SEE PARAGRAPH 2
6. Inspection for Subsurface Cracks Initiating from the Second Aft Row of Fasteners in the
0.032−Inch (0.81 mm) Thick Section of the Top and Bottom Webs at FS640.00, at BL0.00 and
BL4.00, along WL119.12 and WL111.09
A. Equipment Calibration
Refer to Figure 1 and Figure 2.
(1) Do the instrument calibration on the calibration reference standard as follows:
(a) Position the front of the transducer against the −4 angle so that the sound
beam is directed at EDM notch B, see Transducer Placement 2, Figure 1.
Swivel the transducer to obtain a maximized reflection signal form EDM notch
B.
(b) Adjust the instrument (GAIN) control to obtain a 100% full screen height (FSH)
signal from EDM notch B.
(c) Use the instrument (DELAY) and (RANGE) controls to set the leading edge of
the reflection signal from EDM notch B at 20% of the horizontal limit on the
baseline.
B. Inspection Procedure
Refer to Figure 3.
(1) After equipment calibration as outlined in Paragraph 6.A., apply an even layer of 
couplant gel on the 0.32−inch (0.81 mm) thick sections of the top and bottom webs,
601−35006−3 and 601−35006−5 respectively, aft corner at BL0.00 and BL4.00 
adjacent to the edge of the transversal angles (with the vertical flange) at FS640.00. 
The couplant gel must cover approximately 0.50 in. (12.70 mm) each side of the 
second aft row of fasteners.
(2) Position the transducer on the top web 601−35006−3 aft corner with its front against
the transversal angle (the side with the vertical flange) at BL0.00.  Scan both sides of 
the fastener with a slight swivel movement and use the edge of the transversal angle 
as a guide.
(3) Repeat Paragraph 6.B.(2) at BL4.00.
(4) Repeat Paragraph 6.B.(2) and 6.B.(3) for the bottom web 601−35006−5.C
. Acceptance or Rejection Criteria
(1) Any distinct indications with an amplitude signal of 50% FSH or greater is classified
as a crack and cause for rejection.
(2) Record and report results in accordance with company guidelines and policies.
(3) For indications that exceed the allowable limits, it is recommended that you contact
MHIRJ Customer Support (refer to SRM 51−13−01).
7. Inspection for Subsurface Cracks Initiating from the Most Aft Row of Fasteners in the
0.05−Inch (1.27 mm) Thick Section of the Top and Bottom Webs at FS640.00, Between
BL9.50 and BL18.00, along WL119.12 and WL111.09
A. Equipment Calibration
Refer to Figure 1 and Figure 2.
        
TR 53- 135
Page 8of 10
Sep 15/23

### Page 9

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−114
EFFECTIVITY: SEE PARAGRAPH 2
(1) Apply a thick even layer of couplant gel on the 0.05−inch (1.27 mm) thick section of 
the −3 web adjacent to the −4 and −5 angles (0.62−inch (15.75 mm) edge distance
side) of the calibration reference standard EXCM601R30039, as shown in Figure 1. 
(2) Do the instrument calibration on the calibration reference standard as follows:
(a) Position the front of the transducer against the −4 angle so that the sound
beam is directed at EDM notch C, see Transducer Placement 3, Figure 1. 
Swivel the transducer to obtain a maximized reflection signal from EDM notch 
C.
(b) Adjust the instrument (GAIN) control to obtain a 100% full screen height (FSH)
signal from EDM notch C.
(c) Use the instrument (DELAY) and (RANGE) controls to set the leading edge of
the reflection signal from EDM notch C at 20% of the horizontal limit on the 
baseline.
B. Inspection Procedure
Refer to Figure 3.
(1) After equipment calibration as outlined in Paragraph 7.A., apply an even layer of 
couplant gel on the 0.05−inch (1.27 mm) thick section of the top and bottom webs,
601−35006−3 and 601−35006−5 respectively, aft corner between BL9.50 and 
BL18.00 adjacent to the edge of the transversal angles (with the vertical flange) at 
FS640.00.  The couplant gel must cover approximately 0.50 in. (12.70 mm) each side 
of the most aft row of fasteners.
(2) Position the transducer on the top web 601−35006−3 aft corner with its front against
the transversal angle (the side with the vertical flange) at BL9.50.  Scan both sides of 
the fastener with a slight swivel movement and use the edge of the transversal angle 
as a guide.
(3) Repeat Paragaph 7.B.(2) between BL9.50 and BL18.00.
(4) Repeat Paragraph 7.B.(2) and 7.B.(3) for the bottom web 601−35006−5.
C. Acceptance or Rejection Criteria
(1) Any distinct indications with an amplitude signal of 50% FSH or greater is classified
as a crack and cause for rejection.
(2) Record and report results in accordance with company guidelines and policies.
(3) For indications that exceed the allowable limits, it is recommended that you contact
MHIRJ Customer Support (refer to SRM 51−13−01).8. 
Inspection for Subsurface Cracks Initiating from the Second Aft Row of Fasteners in the 
0.05−Inch (1.27 mm) Thick Sections of the Top and Bottom Webs at FS640.00, Between
BL9.50 and BL18.00, along WL119.12 and WL111.09
A. Equipment Calibration
Refer to Figure 1 and Figure 2.
(1) Apply an even layer of couplant gel on the 0.05−inch (1.27 mm) thick section of the
−3 web adjacent to the −4 and −5 angles (0.62−inch (15.75 mm) edge distance 
side) of the calibration reference standard EXCM601R30039, as shown in Figure 1.
        
TR 53- 135
Page 9of 10
Sep 15/23

### Page 10

NONDESTRUCTIVE TESTING MANUAL
Part 4 − Ultrasonic
Part 4
53−61−114
EFFECTIVITY: SEE PARAGRAPH 2
(2) Do the instrument calibration on the calibration reference standard as follows:
(a) Position the front of the transducer against the −4 angle so that the sound
beam is directed at EDM notch D, see Transducer Placement 4, Figure 1.
Swivel the transducer to obtain a maximized reflection signal from EDM notch
D.
(b) Adjust the instrument (GAIN) control to obtain a 100% full screen height (FSH)
signal from EDM notch D.
(c) Use the instrument (DELAY) and (RANGE) controls to set the leading edge of
the reflection signal from EDM notch D at 20% of the horizontal limit on the
baseline.
B. Inspection Procedure
Refer to Figure 3.
(1) After equipment calibration as outlined in Paragraph 8.A., apply an even layer of 
couplant gel on the 0.05−inch (1.27 mm) thick section of the top and bottom webs,
601−35006−3 and 601−35006−5 respectively, aft corner between BL9.50 and 
BL18.00 adjacent to the edge of the transversal angles (with the vertical flange) at 
FS640.00.  The couplant gel must cover approximately 0.50 in. (12.70 mm) each side 
of the second aft row of fasteners.
(2) Position the transducer on the top web 601−35006−3 aft corner with its front against
the transversal angle (the side with the vertical flange) at BL9.50.  Scan both sides of 
the fastener with a slight swivel movement and use the edge of the transversal angle 
as a guide.
(3) Repeat Paragraph 8.B.(2) between BL9.50 and BL18.00.
(4) Repeat Paragraph 8.B.(2) and 8.B.(3) for the bottom web 601−35006−5.
C. Acceptance or Rejection Criteria
(1) Any distinct indications with an amplitude signal of 50% FSH or greater is classified
as a crack and cause for rejection.
(2) Record and report results in accordance with company guidelines and policies.
(3) For indications that exceed the allowable limits, it is recommended that you contact
MHIRJ Customer Support (refer to SRM 51−13−01).
9. Close Out
A. Remove the couplant gel from the inspection surfaces.
B. Make sure that NDTM Part 6, 53−61−114 has been completed.
C. If the finish in the inspection area was removed, replace the finish (Refer to the SRM,
Chapter 51).
D. Remove all tools, equipment and unwanted materials from the work area.
E. Close the aft−equipment compartment door (Refer to Part 1, 51−01−04).
        
TR 53- 135
Page 10 of 10
Sep 15/23

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.