# Brantly Service Bulletin 111: No revision named

- Rights: © Brantly. Filed by the FAA in regulations.gov docket FAA-2012-1093; AD 2014-20-16 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Brantly Service Bulletin 111](https://openairdocs.org/service-documents/brantly/sb-111.md)
- Title as filed: U.S. DOT/FAA - Brantly Service Bulletin No 111 and B-2 MRB Root Skin Inspection ET002
- Pages: 11
- PDF: https://openairdocs.org/files/sha256/ff/9f/ff9fd875ef929ddb79eab1cc929b39d3661d6efaa65d48a6e23e62844da1bd42
- Page: https://openairdocs.org/service-documents/brantly/sb-111/file/ff9fd875ef92

## Text

This text is OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1 (OCR)

BRANTLY INTERNATIONAL INC.  SERVICE BULLETIN No: 111
SERVICE BULLETIN  REVISION: ~ PAGE: 1/4
SERVICE BULLETIN No: 111  February 10, 2011
REVISION: ~
SUBJECT: Outboard Main Rotor Blades
MODELS AFFECTED: See below.
TIME OF COMPLIANCE: See below.
FAA APPROVAL: To be submitted to the FAA for approval
Introduction
The Brantly Maintenance Manuals for the B2 series helicopters call out an inspection for the outboard main rotor
blades in section 1.8.1 Preflight and Daily Inspections. Listed in these sections are criteria for inspecting the
blades for cracks and damage. Cracks in all B2 series main rotor blades are considered unairworthy and are cause
for blade replacement. Service Letter 110 was issued as a reminder of these inspections. This service bulletin
supersedes and cancels the sections of the maintenance manuals mentioned above as well as Service Letter 110. In
addition, this service bulletin supersedes all other service information published for outboard main rotor blade
inspections before the approval date of this service bulletin for p/n 248-101, 248-202, and 248-404. The table
shown below shows each superseded and canceled sections and documents.
Document Name  Revision  Section  Status
Brantly B2 and B2A Maint. Manual  March 1963  1.8.1 a,b,c,d,e,f,g,h, & Fig 2,  Superseded/ Canceled
Pg 6A Rev. S, Mar. 1965
Brantly B2B Maint. Manual  May 15, 1991  1.8.1 a,b,c,d,e,l, & Fig II, Pg  Superseded/ Canceled
4, Rev ~
Brantly Service Letter 110  ~ Oct 31, 2005  All  Superseded/ Canceled
It is suspected that some outboard main rotor blades have been rebuilt in the field. Rebuilding may only be
accomplished by the manufacturer and is not recommended or approved to perform in the field. Any
owner/operator that suspects that a blade has been rebuilt or repaired without FAA approval should remove the
blade from service and report it to the FAA through the Suspected Unapproved Parts Program (SUP) or through
the aviation authority in the applicable country.
Repairs made to outboard main rotor blades must meet or exceed the original design strength of the blade and
require FAA approval.
Applicability
Applies to models B-2, B-2A, or B-2B that have main rotor blades p/n 248-101, 248-202, and 248-404 installed.
Compliance
For Outboard Main Rotor Blades P/N 248-101 and 248-202, before further flight, comply with sections 1 and 2 of
this service bulletin. Thereafter at intervals not to exceed 300 flight hours or 5 calendar years, whichever
occurs first comply with section 1 and at intervals not to exceed 25 flight hours comply with section 2. Also
comply section 3 of this service bulletin before the first flight of each day.
For Outboard Main Rotor Blades P/N 248-404 with less than 10 years time in service or 1000 flight hours,
comply with section 3 of this service bulletin before the first flight of each day.

### Page 2 (OCR)

BRANTLY INTERNATIONAL INC.  SERVICE BULLETIN No: 111
SERVICE BULLETIN  REVISION: ~ PAGE: 2/4
For Outboard Main Rotor Blades P/N 248-404 with more than 10 years time in service or 1000 flight
hours, before further flight, comply with section 1 and 2 of this service bulletin. Thereafter at intervals
not to exceed 300 flight hours or 5 calendar years, whichever occurs first comply with section 1 and at
intervals not to exceed 25 flight hours comply with section 2. Also comply with section 3 of this service
bulletin before the flight of each day.
Contact:
Service Department (service@brantly.com)  Phone 972.829.4600
Brantly International Inc.
621 S. Royal Lane; Suite 100
Coppell, TX 75019-3805
USA
1 Crack Inspection (300 Hour Inspection)
1.1 Remove the outboard main rotor blade. Clean surface to be inspected. Remove any contaminates that
might interfere with the discovery of existing surface indications. Inspect the outboard main rotor
blades for cracks using the Eddy Current Procedure ET002 attached with this service bulletin.
1.2 No cracks or nicks are permitted. No creases, wrinkles or bends are permitted in the trailing edge of the
blades. Verify adequate edge distance between holes such that no additional holes have been added or
extra rivets used to fill stop drilled holes in the root fitting. Any blade that has cracks (especially around
the root of the blade), extra rivets, or stop drilled holes must be removed from service. If any of these
defects are found, remove the blade from service and replace with an airworthy part. Record the results in
2 Delamination Inspections (25 Hour Inspection)
2.1 Remove the outboard main rotor blade. Clean surface to be inspected. Remove any contaminates that
might interfere with the discovery of existing surface indications. Use a suitable light and a 10X
magnifying glass to inspect for cracks in the main rotor blade. Pay particular attention to areas around
rivet holes, the blade root area, and the trailing edge.
2.2 No cracks or nicks are permitted. No creases, wrinkles or bends are permitted in the trailing edge of the
blades. Verify adequate edge distance between holes such that no additional holes have been added or
extra rivets used to fill stop drilled holes in the root fitting. Any blade that has cracks (especially around
the root of the blade), extra rivets, or stop drilled holes must be removed from service. If any of these
defects are found, remove the blade from service and replace with an airworthy part. Record the results in
section 4 of this service bulletin.
2.3 With the outboard main rotor blade removed, inspect the blade for delamination using a tap test.
2.4 Use a metallic coin or tap hammer to lightly tap the blade in the areas that are bonded. Pay particular
attention to the inboard 12 inches (.304m) on the top and bottom. Mark all delaminated areas with a
grease pencil or chalk.
NOTE  Delaminated areas will have a duller, low pitched sound when compared to areas that are not de-
laminated. They may also have a spongy or loose feeling when pressed with the hand.
2.5 No delamination is permitted on the inboard 12 inches (.305m). Delamination is permitted outboard of this
area provided the total delaminated areas do not exceed 10 in? (.254m?). Record the results in section 4.

### Page 3 (OCR)

BRANTLY INTERNATIONAL INC.  SERVICE BULLETIN No: 111
SERVICE BULLETIN  REVISION: ~ PAGE: 3/4
3 Daily Inspections
3.1 Before the first flight of each day, visually inspect the outboard main rotor blade for cracks and wrinkling of
the skin. Pay particular attention to the blade root area, the area around the lead/ag damper mounting fork,
and the blade trailing edge.
3.2 No cracks, nicks, or wrinkling of the skin are permitted. No creases or bends are permitted in the trailing
edge of the blades. If any of these defects are found, remove the blade from service and replace with an
airworthy part.

### Page 4 (OCR)

BRANTLY INTERNATIONAL INC.  SERVICE BULLETIN No: 111
SERVICE BULLETIN  REVISION: ~ PAGE: 4/4
4 Inspection Report for SB-111
Please complete this report for each outboard main rotor blade and send it to Brantly Int. Use the contact
information given in this service bulletin. Describe the cracks and delamination as much as possible and use the
figure to create a sketch of their locations.
Helicopter Information
Reg. #  Serial #  TTIS  Date
Name  Address
Tel.  E-mail
Blade Information
P/N  Serial #  Blade TTIS  Blade TT @ Installation
Helicopter TT @ Blade Installation
12 n (.3)48r;
No Delamination  Bonded Area
Permitted In This
Area
Results/ Description of Cracks and Delamination

### Page 5 (OCR)

Brantly International B-2 Main Rotor Blade Root Skin Inspection  page 1 of 7
1. Technique Number: ET002  3. Component to be examined: P/N 248-101, 248-202, and 248-404 main rotor
blade (MRB) assemblies.
2. Technique Date: 11/07
4. Area of Examination: At fastener locations in the upper and lower surfaces of the 2024-T3 aluminum skin.
5. Purpose of Examination: To detect skin cracks propagating from the fastener holes at various locations, thus
preventing separation of the skin assembly and possible control loss of the aircraft.
6. Technique Written By: Todd L. Jackson
7. Required equipment and tooling:
a. A single channel impedance plane eddy current instrument.
1. The instrument used to develop this procedure was the GE Phasec 2D with a 12 pin LEMO-to-BNC connector
adaptor. A comparable impedance plane instrument that that can obtain equivalent sensitivity can be used.
b. An absolute, shielded, microtip pencil probe with a straight, 45 or 90 degree drop and a BNC-to microdot cable.
1. The probe used to develop this procedure was a MMP 445-40FX 50-500 KHZ and can be obtained from Olympus
NDT (see paragraph d. 1. for contact information). Comparable probe with a microtip diameter may be used.
2. Cover probe coil wear surface with Teflon Tape, Temp-R-Tape, Type T, .006 inch thick by 1 inch wide adhesive
backed or equivalent-available from:
Furon  Furon-CHR Division
29982 Ivy Glenn Drive  or  407 East Street
Laguna Niguel, CA 92677-2004  New Haven, CT 06509-9988
c. A circle template made of non-conducting material to guide the probe concentrically around the fasteners will be
used. A Pickett No. 2100i circles inking template, commonly found at drafting supply stores, was used to develop
this procedure.
d. A calibration standard PN. ET002 (see figure 1).
1. Can be locally manufactured or obtained from Olympus NDT (formerly NDT Engineering Corporation) at:
19620 Russell Rd
Kent, WA 98032
Phone (1) (253) 872-0857
e. Suitable work surface to position the removed blade for inspection.
8. Basic Eddy Current Instrument Operating Parameters (Phasec 2D):
a. Turn Instrument on by depressing the on (green) button.
b. Press the menu button to access the operating parameters. Verify that the following parameters are set for initial
instrument calibration. Refer to the instrument operating manual for parameter adjustment procedure.
Note- The parameters listed below will vary slightly in description from one instrument make and model to another.
(FREQ)  (ALARM)  (MEMORY)
(1) GAIN XY1 set to 30.0/45.0  Optional  See Note 1
(2) PHASE 1° set to 0
(2) FREQ1 kHz set to 200 kHz  (PROBE)
(3) Filter set to BP LOCK.  MODE set to Normal Single.
(4) HP/LP filters set to DC/30.0.  (TRACE DISP)  PROBE ID N/A, Unknown.
(5) INPUT GAIN1 set to High.  (1) DISPLAY set to Spot.  LOAD uH set to 120 or balance hold.
(6) PROBE1 set to Absolute.  (2) GRATICULLE set to Grid 2.  DRIVE dB set to +8
(OUTPUT)  (3) SPOT XY set to 115/-30  (4) SPOT INFO set to None.  BAL/CLR MOD set to Single.
(1) ANALOG O/P 1 set to X1.  (5) PERSIST set to 5.0 s.
(2) ANALOG O/P 2 set to X1.  (6) SWEEP set to 5.0 s.

### Page 6 (OCR)

Brantly International B-2 Main Rotor Blade Root Skin Inspection  page 2 of 7
9. Overview of the Inspection:
a. Surface eddy current inspect to detect cracks in the skin assembly on the upper and lower surfaces of the main rotor
blade (MRB), adjacent to the heads of the MS20426-AD3 and AD4 rivets in the following areas (see Figure 2):
1. At the riveted area common to the hinge block attach fitting, sub-divided into fastener spacing configurations, and
2. at the riveted row common to the spar.
Figure 1- Calibration Standard ET002 Details
- 3.00"  .125"
1.30" 4 4.50"→  50"→*.50"→+.50"*.50"*
FLAG NOTES
MACHINED OUT OF .125 2024-
'NOTCH D  1 T3 ALUMINUM PLATE.
1.00"  100° COUNTER SINK ALL  FASTENER LOCATIONS
.130"  EXCEPT LOCATIONS 5.
.020"  FABRICATE FROM .016" THICK
MAX  2 2024-T3 CLAD ALUMINUM
SHEET. 100° DIMPLE
COUNTER SINK ALL EXCEPT
.980"  MIN.  NOTCH C  3.00"  FASTENER LOCATIONS 5.
MS20426-AD3 RIVETS (3/32"
3 DIAMETER). MAKE SHOP
HEADS ½ D X 2 D STANDARD
NOTCH B NOTCH A  2.00"  MS20426-AD4 RIVETS (1/8"
50"
4 DIAMETER). MAKE SHOP
HEADS ½ D X 2 D STANDARD
5 STACK DRILL .200" DIAMETER
50"  AND DEBUR.
ET002 -XXX  VIBRO-ETCH OR ELECTRO-
6 ETCH PART NUMBER AND
*.60"→  80"  *.50"-  •.50"→  .016"  SERIAL NUMBER INTO TOP
-.300"  .30"  .109"  SURFACE
NOTCH DIMENSIONS (INCHES)
NOTCH  LENGTH  WIDTH  DEPTH
A  200" MEASURED (.035" FROM EDGE OF COUNTER SINK DIMPLE)  .010" MAXIMUM  THROUGH
EDGE OF FASTENER HOLE TO EDGE OF FASTENER HOLE  .010" MAXIMUM  THROUGH
EDGE OF FASTENER HOLE TO EDGE OF SHEET METAL  .010" MAXIMUM  THROUGH
D  EDGE OF FASTENER HOLE TO EDGE OF SHEET METAL  010" MAXIMUM  THROUGH
NOTE-NOTCH LOCATIONS MUST BE WITHIN +/- 0.005 OF THE CENTERLINE OF THE HOLE.
DIMENSIONAL TOLERANCE (INCHES)
XXXX = +/- 0.005
XXX = +/- 0.025
X.X = +/- 0.050
ANGLES: +/- 1.0 DEGREE
SURFACE ROUGHNESS = 63 Ra OR BETTER

### Page 7 (OCR)

Brantly International B-2 Main Rotor Blade Root Skin Inspection  page 3 of 7
Figure 2: Fastener Locations at Hinge Block Fitting and Spar Areas
SKIN-TO-SPAR FASTENERS IN AREA "B" (SEE FIGURE 3)  LEADING
SKIN FORWARD EDGE  EDGE
SKIN  SKIN
SKIN-TO-HINGE BLOCK  FASTENER AREA "A"  TRAILING
(SEE FIGURE 3)  BLADE ROOT <  BLADE TIP  EDGE
Figure 3: Fastener Identification and Corresponding Probe Calibration Positions on ET002
SCAN PATTERN  SKIN EDGE LINE  PROBE  PROBE
USING PROBE GUIDE  AREA "B" FASTENERS  POSITION 8  POSITION 9
(SEE FIGURE 5)  @ NOTCH D
• PROBE  POSITION  •0
POSITION 2  PROBE  9 (O O
PROBE POSITION 1
O DAMPENER ATTACH HOLE  SPAR-TO-HINGE  PROBE
AREA "A", SEE PAR. 10 AND 11  L BLOCK LINE_  POSITION 3
@ NOTCH C
• INSUFFICIENTILY SPACED  AREA "A" FASTENERS
FASTENERS, AREA "A",
SEE PAR. 12 AND 13  -1002
@SUFFICIENTLY SPACED  KNOWN LOCATIONS OF  PROBE  PROBE
FASTENERS, AREA "A",  SEE PAR. 14 AND 15  SKIN CRACKS EMANATING  FROM FASTENERS  POSITION 4  PROBE  PROBE  POSITION 7
O SKIN-TO-SPAR FASTENERS  LOCATED IN AREA "A"  POSITION 5  POSITION 6
AREA "B", SEE PAR. 16 AND 17  @ NOTCH B  @ NOTCH A
10. Instrument Calibration for Inspection of Skin around Dampener Attach Hole (Area "A")
a. Turn instrument on and ensure the basic operating parameters are set (see paragraph 8).
b. Place Teflon tape over probe coil. Connect the probe to the instrument and select a balance load.
c.  Place the probe on position 1 of the ET002 reference standard, and press balance/lift-off. If needed, adjust Spot
XY position to bring flying dot into position as shown in figure 4.
d.  Lift the probe coil approximately 1" from the surface of the reference standard. The signal trace should move
horizontally from right to left on the screen from the balance point shown in figure 4. Note: The lift-off phase angle
will be automatically set as shown in figure 4, when balance/lift off is pressed and held. If the instrument does not
have an "auto phase" feature, rotate the phase angle until the desired results are obtained.
e.  Place the probe on probe position 2 of the ET002 reference standard (see figure 3) and scan around the hole
using the circle template as a probe guide as shown in figure 5. Observe the screen while scanning. The flying dot
should not move more than 1-2 division lines vertically or horizontally from the balance point. Note: If the dot drifts
more than 1-2 divisions horizontally, the probe may be tilted excessively. If the dot drifts more than 1-2 divisions
vertically, it is positioned too close to the edge of the fastener.
f.  Use the same circle template hole to scan around the hole at probe position 3 and over notch C (see figure 3).
The signal trace should look similar to that shown in figure 4. Adjust the instrument gain to obtain an 80% screen
height vertical movement from the notch.

### Page 8 (OCR)

Brantly International B-2 Main Rotor Blade Root Skin Inspection  page 4 of 7
Figure 4: Screen Presentations from Lift-Off and Notches A, B and C
VERTICAL (Y) DIVISION LINES
TYPICAL NOTCH
SIGNAL FROM NOTCHS A, B AND C  OR CRACK SIGNAL
(PROBE POSITIONS 3, 5 AND 6)  180%
REJECT OR ALARM LEVEL -  50%
LIFT-OFF LINE
THE FLYING DOT SHOULD NOT MOVE MORE  FLYING DOT
THAN 1-2 DIVISIONS VERTICALLY OR  20%
HORIZONTALY FROM BALANCE POINT
DURING SCAN OVER DEFECT FREE AREA
HORIZONTAL (X) DIVISION LINES
Figure 5: Proper Circle Selection for Probe Guide
CIRCULAR SCAN PATTERN  CIRCLE TEMPLATE USED
AS A PROBE GUIDE
MICRO TIP PROBE  MICRO TIP PROBE
ET002  FASTENER
CALIBRATION  HEAD
STANDARD
CALIBRATION NOTCH "A  CALIBRATION NOTCH "C"
11. Inspection of Skin around Dampener Attach Hole (Area "A")
a. Place the same circle template hole (selected in step e. of paragraph 10.) concentrically over dampener hole as
shown in figure 5.
b. Press balance/lift off to balance the instrument, if needed. Adjust Spot XY position, if needed, to bring flying dot
into position as shown in figure 4.
c. Scan probe around the hole while observing the instrument screen.
d. Turn MRB over and repeat the preceding steps on the opposite side of the blade.
e. Any signal obtained in preceding steps of this paragraph that exhibits a rapid upscale vertical movement equal to
or exceeding 50% screen height will be cause for rejection.
f.  Determine the length or end(s) of the crack by scanning back and forth across the length until the vertical trace
returns to the balance point and mark location. Measure and record the location and length of the crack.

### Page 9 (OCR)

Brantly International B-2 Main Rotor Blade Root Skin Inspection  page 5 of 7
12. Instrument Calibration for Inspection of Skin adjacent to the Insufficiently Spaced Fasteners (Area "A")
a. Turn instrument on and ensure the basic operating parameters are set (see paragraph 8).
b. Place Teflon tape over probe coil. Connect the probe to the instrument and select a balance load.
c. Place the probe on position 1 of the ET002 reference standard, and press balance/lift-off. If needed, adjust Spot
XY position to bring flying dot into position as shown in figure 4.
d. Lift the probe coil approximately 1" from the surface of the reference standard. The signal trace should move
horizontally from right to left on the screen from the balance point shown in figure 4. Note: The lift-off phase angle
will be automatically set as shown in figure 4, when balance/lift off is pressed and held. If the instrument does not
have an "auto phase" feature, rotate the phase angle until the desired results are obtained.
Place the probe on position 4 of the ET002 reference standard (see figure 3) and scan around the hole using the
circle template as a probe guide as shown in figure 5. Observe the screen while scanning. The flying dot should
not move more than 1-2 division lines vertically or horizontally from the balance point. Note: If the dot drifts more
than 1-2 divisions horizontally, the probe may be tilted excessively. If the dot drifts more than 1-2 divisions
vertically, it is positioned too close to the edge of the fastener.
f.  Use the same circle template hole to scan around the fastener at probe position 5 and over notch B. The signal
trace should look similar to that shown in figure 4. Adjust the instrument gain to obtain an 80% screen height
vertical movement from the notch.
13. Inspection of Skin adjacent to the Insufficiently Spaced Fasteners (Area "A")
a. Place the same circle template hole (selected in step e. of paragraph 12.) concentrically over the fastener
adjacent to the skin being inspected (similar to the example given in figure 5).
b.  Press balance/lift off to balance the instrument. If needed, adjust Spot XY position to bring flying dot into position
as shown in figure 4.
c. Scan probe around the fastener while observing the instrument screen.
d.  Repeat the preceding steps of this paragraph until the skin is inspected at all like spaced fasteners located in Area
e.  Turn MRB over repeat preceding steps of this paragraph until the skin is inspected at all like spaced fastener
locations in Area "A".
e. Any signal obtained in preceding steps of this paragraph that exhibits a rapid upscale vertical movement equal to
or exceeding 50% screen height will be cause for rejection.
f.  Determine the length or end(s) of the crack by scanning back and forth across the length until the vertical trace
returns to the balance point and mark location. Measure and record the location and length of the crack.
14. Instrument Calibration for Inspection of Skin adjacent to the Sufficiently Spaced Fasteners (Area "A")
a. Turn instrument on and ensure the basic operating parameters are set (see paragraph 8). Place Teflon tape over
probe coil. Connect the probe to the instrument and select a balance load.
b. Place the probe on position 1 of the ET002 reference standard, and press balance/lift-off. If needed, adjust Spot
XY position to bring flying dot into position as shown in figure 4.
c.  Lift the probe coil approximately 1" from the surface of the reference standard. The signal trace should move
horizontally from right to left on the screen from the balance point shown in figure 4. Note: The lift-off phase angle
should be automatically set as shown in figure 4, when balance/lift off is pressed and held. If the instrument does
not have an "auto phase" feature, rotate the phase angle until the desired results are obtained.
Continued on page 6

### Page 10 (OCR)

Brantly International B-2 Main Rotor Blade Root Skin Inspection  page 6 of 7
14. Instrument Calibration for Inspection of Skin Adjacent to the Sufficiently Spaced Fasteners (Area "A")
Continued from page 5.
d. Place the probe on position 6 of the ET002 reference standard (see figure 3) and scan around the fastener using
the circle template as a probe guide as shown in figure 5. Observe the screen while scanning. The flying dot
should not move more than 1-2 division lines vertically or horizontally from the balance point. Note: If the dot drifts
more than 1-2 divisions horizontally, the probe may be tilted excessively. If the dot drifts more than 1-2 divisions
vertically, it is positioned too close to the edge of the fastener.
e.  Use the same circle template hole to scan around the fastener at probe position 7 and over notch A (see figure 3).
The signal trace should look similar to that shown in figure 4. Adjust the instrument gain to obtain an 80% screen
height vertical movement from the notch.
15. Inspection of Skin Adjacent to the Sufficiently Spaced Fasteners (Area "A")
a. Place the same circle template hole (selected in step d. of paragraph 14.) concentrically over the fastener
adjacent to the skin being inspected (similar to the example given in figure 5).
b. Press balance/lift off to balance the instrument. If needed, adjust Spot XY position to bring flying dot into position
as shown in figure 4.
c. Scan probe around the fastener while observing the instrument screen.
d. Repeat the preceding steps of this paragraph until the skin is inspected at all like spaced fasteners located in
Area "A".
e. Turn MRB over repeat the preceding steps of this paragraph until the skin is inspected at all like spaced fastener
locations in Area "A"
f.  Any signal obtained in preceding steps of this paragraph that exhibits a rapid upscale vertical movement equal to
or exceeding 50% screen height will be cause for rejection.
g. Determine the length or end(s) of the crack by scanning back and forth across the length until the vertical trace
returns to the balance point and mark location. Measure and record the location and length of the crack.
16. Instrument Calibration for Inspection of Skin Adjacent to the Skin-to-spar Fasteners (Area "B")
a. Turn instrument on and ensure the basic operating parameters are set (see paragraph 8).
b. Place Teflon tape over probe coil. Connect the probe to the instrument and select a balance load.
C.  Place the probe on position 1 of the ET002 reference standard, and press balance/lift-off. If needed, adjust Spot
XY position to bring flying dot into position as shown in figure 4.
d.  Lift the probe coil approximately 1" from the surface of the reference standard. The signal trace should move
horizontally from right to left on the screen from the balance point shown in figure 4. Note: The lift-off phase angle
will be automatically set as shown in figure 4, when balance/lift off is pressed and held. If the instrument does not
have an "auto phase" feature, rotate the phase angle until the desired results are obtained.
e.  Place the probe on position 8 of the ET002 reference standard (see figure 7) and scan around the fastener using
the circle template as a probe guide as shown in figure 5. Observe the screen while scanning. The flying dot
should not move more than 1-2 division lines vertically or horizontally from the balance point. Note: If the dot
drifts more than 1-2 divisions horizontally, the probe may be tilted excessively. If the dot drifts more than 1-2
divisions vertically, it is positioned too close to the edge of the fastener or the edge of the skin. A signal (like the
one shown in figure 6) is caused by the probe being in close proximity to the edge of the skin and must not be
confused with the notch signal or a crack.
f.  Use the same circle template hole to scan around the hole at probe position 9 and over notch D (see figure 6).
The signal trace should look similar to that shown in figure 6. Adjust the instrument gain to obtain an 80% screen
height vertical movement from the notch.

### Page 11 (OCR)

Brantly International B-2 Main Rotor Blade Root Skin Inspection  page 7 of 7
Figure 6: Screen Presentations from Lift-Off, Skin Edge and Notch D
VERTICAL (Y) DIVISION LINES
TYPICAL NOTCH D.....
SIGNAL FROM NOTCHS A, B AND C  OR CRACK SIGNAL
(PROBE POSITIONS 3, 5 AND 6)  80%
REJECT OR ALARM LEVEL  50%  EDGE OFSKIN SIGNAL
THE FLYING DOT SHOULD NOT MOVE MORE  LIFT-OFF LINE  , FLYING DOT
THAN 1-2 DIVISIONS VERTICALLY OR  20%
HORIZONTALY FROM BALANCE POINT
DURING SCAN OVER DEFECT FREE AREA
HORIZONTAL (X) DIVISION LINES
Figure 7: Scan Technique around Area "B" Fasteners
CIRCULAR SCAN PATTERN
MICRO TIP PROBE
ET002  CIRCLE TEMPLATE USED
CALIBRATION  FASTENER  AS A PROBE GUIDE
STANDARD  HEAD
CALIBRATION NOTCH "D"  EDGE OF SKIN
17. Inspection of Skin around Skin-to-Spar Attach Fasteners (Area "B")
a.  Place the same circle template hole (selected in step e. of paragraph 16.) concentrically over the fastener as
shown in figure 7.
b.  Press balance/lift off to balance the instrument, if needed. Adjust Spot XY position, if needed, to bring flying dot
into position as shown in figure 6.
c. Scan probe around the fasteners while observing the instrument screen.
d. Turn MRB over and repeat the preceding steps on the opposite side of the blade.
e. Any signal obtained in preceding steps of this paragraph that exhibits a rapid upscale vertical movement equal to
or exceeding 50% screen height will be cause for rejection.
f.  Determine the length or end(s) of the crack by scanning back and forth across the length until the vertical trace
returns to the balance point and mark location. Measure and record the location and length of the crack.
18. Reporting
a. Report inspection results to: Brantly International Inc., 621 S. Royal Lane Suite 100 Coppell, TX 75019-3805, USA
b. Include aircraft S/N, MRB PN., MRB S/N, MRB total time since new, location and length of crack(s) in report.
Technique Approved By: Todd L Jackson, Co LIII, JETS, Inc.  Date: 11/01/2007
Technique Accepted By:  Date:

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.
