# CASA Alert Operators Transmission AOT-C295-52-0001

Copy: No revision named ("AOT-C295-52-0001-I00"), 3 pages: PDF https://openairdocs.org/files/sha256/c3/6a/c36a884d4af27b68cbaad910c2a30ae96b7ba6647ef618b90b769e650ba70dc3; text https://openairdocs.org/service-documents/casa/aot-aot-c295-52-0001/file/c36a884d4af2.md. Rights: © CASA. Filed by the FAA in regulations.gov docket FAA-2017-0123; AD 2017-10-15 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [CASA](https://openairdocs.org/service-documents/casa.md)
- Type: Other document (Alert Operators Transmission)
- Number: AOT-C295-52-0001
- Page: https://openairdocs.org/service-documents/casa/aot-aot-c295-52-0001

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2017-10-15](https://openairdocs.org/ad/2017-10-15.md), effective Jun 29, 2017: No revision named

## Text (3 pages)

Rights: © CASA. Filed by the FAA in regulations.gov docket FAA-2017-0123; AD 2017-10-15 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

Ref No.: AOT-C295-52-0001 
Rev No.: 0 Rev Date:  04 Sept 2014 
SERVICES DIRECTORATE 
Pº John Lennon s/n 
28906 Getafe, Madrid, SPAIN 
MTA.TechnicalService@military.airbus.com 
 
Alert Operators Transmission 
 Page 1/3 
 ATA Chapter: 52 
Subject: 
 
EXTERNAL HANDLE OF REAR EMERGENCY DOOR JAMMING 
 
Aircraft Type: C-295   
Applicability:  ALL 
Referenced Documents: IPC 52-21-13, AMM CA-A-52-21-13-00A-920A-A 
  
  
 
1. REASON FOR REVISION 
This is the first issue of the AOT. 
2. REASON 
A CN-235 Operator has recently reported the inability to open the rear emergency door from the outside. 
According to the initial investigation, this was due to the jamming of the spring mechanism which pushes out the 
external handle from its retracted position flush with the door skin. As the C -295 aircrafts are fitted with a similar 
emergency door, this AOT is being released to inform all Operators of the event and of the relevant 
recommendations issued by Airbus Defence and Space (Airbus DS). 
2.1 FACTS 
The operator was not able to open the rear eme rgency door from outside when trying to perform a scheduled 
maintenance task with the aircraft on ground. The mechanism was jammed and the external handle (item 80 of 
Figure 1) was not pushed out of the door when its retaining c atch (item 120 of figure 1) was operated. The handle 
mechanism was disassembled and its inspection showed metallic burrs in the slotted tube (item 70  of Figure 1 ). 
After the burrs were removed, the mechanism was lubricated and installed again and the aircraft returned to service 
with the rear emergency door fully operational. 
 
2.2 CONSEQUENCES 
Airbus DS has assessed the event and concluded that the defect observed on the tube would not have prevented 
proper operation of the door from inside the aircraft. Nevertheless, the ability to open the emergency door from the 
outside is required to ensure quick access to the aircraft, particularly during an emergency evacuation and in case of 
an incapacitated crew. 
 
2.3 AIM 
The aim of this AOT is to inform all C-295 Operators of the reported occurre nce and to recommend the functional 
check of the external handle mechanism of the emergency doors prior to the next flight.

### Page 2

Reference No.: AOT-C295-52-0001 
Revision No.: 0 Date
: 
 04 Sept 2014 
Alert Operators Transmission 
 Page 2/3 
 ATA Chapter: 52 
Subject: EXTERNAL HANDLE OF REAR EMERGENCY DOOR JAMMING 
 
 
3. SHORT TERM ACTION 
 
Airbus Defence and Space recommends doing a functional check of the external handle mechanism of the 
emergency doors by simply operating the retaining catch of the handle and then setting back the handle to its fully 
closed position. Make sure the handle pops out of its seating to the operating position when the catch is released. 
   
In case of failure of  the functional check (including the case of unexpected resistance on the mechanism) , Airbus 
Defence and Space recommends disassembling the Emergency door handle  according to the  AMM CA-A-52-21-
13-00A-920A-A and examine the mechanism for any damaging condition and unexpected material . Please report 
back to Airbus DS any finding and the result of examination. 
 
It is recommended to perform the functional check of the external handle upon receiving this revision 00 of the AOT 
and prior to the next flight. 
4. REPORTING 
Questions about this AOT and inspection results with or without findings are to be sent to Airbus Military Technical 
Assistance Center (AMTAC): 
Telephone: (+34) 91 600 79 99 
E-mail: MTA.TechnicalService@military.airbus.com 
 
 
 
 
 
 
 
 
 
 
 
Released by  
Pedro Solera on behalf of Yolanda Lara  
 
Electronically Validated 
    
© EADS CASA.2014. All rights reserved. Confidential and proprietary document.  
This document and all information contained herein is the sole property of EADS CASA. 
No intellectual property rights are granted by the delivery of this document or the disclosure of its content. This document shall not be reproduced or disclosed to a third party without the express 
written consent of EADS CASA. 
This document and its content shall not be used for any purpose other than that for which it is supplied.  
©EADS CASA 2014 All right reserved

### Page 3

Reference No.: AOT-C295-52-0001 
Revision No.: 0 Date
: 
 04 Sept 2014 
Alert Operators Transmission 
 Page 3/3 
 ATA Chapter: 52 
Subject: EXTERNAL HANDLE OF REAR EMERGENCY DOOR JAMMING 
 
 
 
 
                                                             Figure 1: EMERGENCY DOOR HANDLE INSTALLATION

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.