# CASA Service Bulletin 235-26-0005

Copy: No revision named ("SB 235-26-0005-C-00-I"), 49 pages: PDF https://openairdocs.org/files/sha256/14/10/141071a28652cd8644708c225c09f1c209a0489d4cb409877ab9591cbdfaf88b; text https://openairdocs.org/service-documents/casa/sb-235-26-0005/file/141071a28652.md. Rights: © CASA. Filed by the FAA in regulations.gov docket FAA-2017-0555; AD 2017-19-07 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [CASA](https://openairdocs.org/service-documents/casa.md)
- Type: Service bulletin (Service Bulletin)
- Number: 235-26-0005
- Page: https://openairdocs.org/service-documents/casa/sb-235-26-0005

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2017-19-07](https://openairdocs.org/ad/2017-19-07.md), effective Oct 25, 2017: No revision named

Also cited in [1 proposed AD](https://openairdocs.org/service-documents/casa/sb-235-26-0005/proposed.md).

## Text (49 pages)

Rights: © CASA. Filed by the FAA in regulations.gov docket FAA-2017-0555; AD 2017-19-07 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

CN-235 - SERVICE BULLETIN
FIRE PROTECTION
ENGINE FIRE EXTINGUISHING. MODIFICATION OF THE HARNESS INSTALLATION IN THE
FIRE EXTINGUISHER BOTTLES.
1. GENERAL INFORMATION
A. EFFECTIVITY
(1) Models
CN-235, CN-235–200, CN-235–300.
(2) Aircraft
The Version/MSN relationship is given for information only . This
relationship is correct at the time of issue in accordance wi th
the information available in EADS-CASA. Any future changes that
are the result of the transfer of an aircraft from one version
to another will not be reflected in this list unless the Servi ce
Bulletin is revised for another reason.
VERSION MSN KIT No.
AE01 C-135. SB235260005K05 or K07
AE02 C-139, C-143,
C-145.
SB235260005K05 or K07
IB01 C-007, C-010,
C-012.
SB235260005K04 or K07
IB02 C-018, C-030. SB235260005K04 or K07
L302 C-130. SB235260005K05 or K07
L303 C-176, C-177,
C-182, C-186.
SB235260005K03 or K07
QC02 C-042. SB235260005K04 or K07
SM01 C-166, C-169,
C-171.
SB235260005K03 or K07
NOTE : The Service Bulletin SB-235-26-0004 will not be
applicable to the aircraft that accomplish this Service
Bulletin. Also, this Service Bulletin can be accomplished
independently if the SB-235-26-0004 has been accomplished
before.
(3) Spares
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 1 of 48

### Page 2

CN-235 - SERVICE BULLETIN
None
B. CONCURRENT REQUIREMENTS
None
C. REASON
(1) HISTORY
An incorrect electrical connection has been found on the eng ine
fire extinguisher bottles of several CN-235 aircraft. This
is due to a cross connection between cartridges 1 and 2 or a
cross connection between the positive terminal and the nega tive
terminal of the cartridge.
(2) OBJETIVE / ACTION
In the fire extinguisher circuit, modify the installation o f the
harnesses that go to the fire extinguisher cylinders WB5 (WB 6):
- Add the necessary connectors zones for each version so that
each cartridge has a connectors zone.
- Install the connectors zone with the plug in the side of the
bottle.
- Supply new harnesses between the connectors zone and the
bottle. These ones contain the identification sleeves that
identify the wires to connect the positive and the negative
terminals correctly.
(3) ADVANTAGES
To prevent an incorrect connection if maintenance tasks or
functional tests are done.
(4) OPERATIONAL/MAINTENANCE CONSEQUENCE
None
D. DESCRIPTION
To accomplish this Service Bulletin it is necessary to:
EFFECTIVITY: ALL
- Put the aircraft in the safe condition for maintenance task s.
- Get access to the work area.
EFFECTIVITY: SM01 and L303 if SB–235–26–0004 has not been ac com-
plished.
- Remove the Fire Extinguisher Cylinders WB5 (WB6).
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 2

### Page 3

CN-235 - SERVICE BULLETIN
- Connectors zone WB13M/WB13H (WB10M/WB10H):
. Replace harnesses between the connectors zone and the bott le.
- Connectors zone WB15M/WB15H (WB14M/WB14H):
. Re-locate installed bonding points.
. Install supports for the connectors zones.
. Connect and install the receptacle, WB15H (WH14H).
. Install new harnesses with the plug, WB15M (WB14M).
- Install the Fire Extinguisher Cylinders WB5 (WB6).
EFFECTIVITY: AE01, AE02, IB01, IB02, L302 and QC02 if SB–235 –26–0004
has not been accomplished.
- Remove the Fire Extinguisher Cylinders WB5 (WB6).
- Connectors zone WB13M/WB13H (WB10M/WB10H):
. Install new bonding points.
. Install supports for the connectors zones.
. Install clamps.
. Re-identify installed wires (except versions AE01, AE02 a nd L302).
. Connect and install the receptacle, WB13H (WH10H).
. Install new harnesses with the plug, WB13M (WB10M).
- Connectors zone WB15M/WB15H (WB14M/WB14H):
. Re-locate installed bonding points.
. Install supports for the connectors zones.
. Connect and install the receptacle, WB15H (WH14H).
. Install new harnesses with the plug, WB15M (WB14M).
- Install the Fire Extinguisher Cylinders WB5 (WB6).
EFFECTIVITY: AE01, AE02, IB01, IB02, L302, L303, SM01 and QC 02 with
SB–235–26–0004 accomplished.
- Remove and discard installed harness between the connecto rs zone
and the bottle.
- Disconnect and discard installed plug.
- Connect and install the receptacle.
- Install new harnesses with the plug.
EFFECTIVITY: ALL
- Do tests.
- Close the access panels.
- Record the accomplishment.
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 3

### Page 4

CN-235 - SERVICE BULLETIN
E. COMPLIANCE
(1) Classification
Recommended
(2) Accomplishment Timescale
None
F. APPROVAL
The technical content of this document has been approved by t he
authority of the DOA No. EASA.21J.032.
This issue is a translation of SB-235–26–0005. In case of any dis-
agreement, reference should be made to the Spanish Original issue,
which has been approved by the authority of the DOA No. EASA.2 1J.032
G. MANPOWER
The manpower estimates given in this Service Bulletin are ba sed on the
direct labour cost to do the work. These estimates assume tha t the
work will be done by experienced personnel, and may need to be revised
upwards to suit operators' circumstances. The estimates do not
include the time to prepare, plan or inspect the work. Manufa cture
and procurement of part and tools, drying times for paints, s ealants,
etc., and general administration works are also not include d.
Kit SB235260005K03
ON AIRCRAFT: 5
TOTAL MANHOURS : 5
ELAPSED TIME(HRS):
NOTE : The indicated time is an approximated time for the
accomplishment of the modification described in Service
Bulletin.
Kit SB235260005K04
ON AIRCRAFT: 8
TOTAL MANHOURS : 8
ELAPSED TIME(HRS):
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 4

### Page 5

CN-235 - SERVICE BULLETIN
NOTE : The indicated time is an approximated time for the
accomplishment of the modification described in Service
Bulletin.
Kit SB235260005K05
ON AIRCRAFT: 8
TOTAL MANHOURS : 8
ELAPSED TIME(HRS):
NOTE : The indicated time is an approximated time for the
accomplishment of the modification described in Service
Bulletin.
Kit SB235260005K07
ON AIRCRAFT: 3
TOTAL MANHOURS : 3
ELAPSED TIME(HRS):
NOTE : The indicated time is an approximated time for the
accomplishment of the modification described in Service
Bulletin.
H. WEIGHT AND BALANCE
(1)Variation of the Standard Basic Empty Weight (SBEW).
====Kit SB235260005K03:====Weight = +0.16 Kg
====Kit SB235260005K04:====Weight = +0.33 Kg
====Kit SB235260005K05:====Weight = +0.34 Kg
====Kit SB235260005K07:====Weight = +0.12 Kg
(2) Variation of the momentum with respect to the reference p lane.
====Kit SB235260005K03:====Momentum = +1.88 Kg.m
====Kit SB235260005K04:====Momentum = +3.79 Kg.m
====Kit SB235260005K05:====Momentum = +4.00 Kg.m
====Kit SB235260005K07:====Momentum = +1.47 Kg.m
I. ELECTRICAL LOAD DATA
Not changed
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 5

### Page 6

CN-235 - SERVICE BULLETIN
J. REFERENCES
Aircraft Maintenance Manual (AMM): 06-41-57, 20-21-00, 20-27-00,
20-28-00, 20-38-00, 20-50-00,
24-40-00, 26-21-11
Structural Repair Manual (SRM): 51-41-00
K. PUBLICATIONS AFFECTED
Aircraft Maintenance Manual (AMM): 26-21-11
Illustrated Parts Catalog (IPC): 26-21-10
Wiring Diagrams Manual (WDM): 26-20-30, 26-21-00
L. INTERCHANGEABILITY/MIXABILITY
Not applicable
M. RELATED FIGURES
- Figure 1 Modification of the Engine Fire Extinguisher Circuit (WB).
- Figure 2 Modification of the Engine Fire Extinguisher Circuit (WB).
- Figure 3 Modification of the Engine Fire Extinguisher Circuit (WB).
- Figure 4 Modification of the Engine Fire Extinguisher Circuit (WB).
- Figure 5 Modification of the Engine Fire Extinguisher Circuit (WB).
- Figure 6 Modification of the electrical installation.
- Figure 7 Modification of the electrical installation.
- Figure 8 Modification of the electrical installation.
- Figure 9 Schematic of discharge of the fire extinguisher bottles.
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 6

### Page 7

CN-235 - SERVICE BULLETIN
2. MATERIAL INFORMATION
A. MATERIAL - PRICE AND AVAILABILITY
(1) Material
Operators with aircraft shown in the effectivity of this Ser vice
Bulletin should send a purchase order to EADS-CASA. Quote th e
number of the Service Bulletin. The address is:
EADS-CASA
SERVICES - MATERIAL SUPPORT
Avda. de Aragón, 404
28022 MADRID
SPAIN
Fax: +34 91 585 55 05
(2) Price and Availability
Sales terms must be agreed between the Operator and EADS-CAS A in
accordance with the established procedure.
B. INDUSTRY SUPPORT INFORMATION
None
C. LIST OF COMPONENTS
SB235260005K03
FIG ITEM N/P NEW QTY UM KEYWORDITEM N/P OLD INT INST DISP
11 91 35–69 926–0005 1 Harne ss
92 35–69927–0005 1 Harness
93 35–69968–0007 1 Harness 35–69968–00 03 1
94 35–69967–0007 1 Harness 35–69967–00 03 1
30 M85049/52–1–8N 2 Clamp
40 NAS1149DN416H 8 Washer
50 MS21042–04 8 Nut
60 NAS1101–04–6 8 Screw
70 35–69771–0201 2 Support
80 MS20470AD4–5 6 Rivet
110 CAN68251–8–98
SNA
2 Connctr
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 7

### Page 8

CN-235 - SERVICE BULLETIN
FIG ITEM N/P NEW QTY UM KEYWORDITEM N/P OLD INT INST DISP
120 NAS1801–3–12 2 Screw
130 MS35650–302 2 Nut
140 NAS679A3W 2 Nut
150 MS35338–43 4 Washer
160 NAS1149D0332J 6 Washer
300 35–A3350–0003 1 Labels
Set
NOTE : INT 03 – Not interchangeable
NOTE : INST DISP 1 – Discard
SB235260005K04
FIG ITEM N/P NEW QTY UM KEYWORDITEM N/P OLD INT INST DISP
12 91 35–69926–0005 1 Harness
92 35–69927–0005 1 Harness
93 35–69968–0007 1 Harness
94 35–69967–0007 1 Harness
20 CAN68251–8–33
SNA
2 Connctr
30 M85049/52–1–8N 4 Bckshll
40 NAS1149DN416H 16 Washer
50 MS21042–04 16 Nut
60 NAS1101–04–6 16 Screw
70 35–69771–0201 4 Support
80 MS20470AD4–5 12 Rivet
110 CAN68251–8–98
SNA
2 Connctr
120 NAS1801–3–12 4 Screw
130 MS35650–302 4 Nut
140 NAS679A3W 4 Nut
150 MS35338–43 8 Washer
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 8

### Page 9

CN-235 - SERVICE BULLETIN
FIG ITEM N/P NEW QTY UM KEYWORDITEM N/P OLD INT INST DISP
160 NAS1149D0332J 12 Washer
200 AS21919WDG04 2 Clamp
201 NAS1801–3–10 2 Screw
202 NAS679A3 2 Nut
203 NAS1149D0316H 2 Washer
300 35–A3349–0001 1 Labels
Set
330 CAN36163–03–9 4 Sleeve
SB235260005K05
FIG ITEM N/P NEW QTY UM KEYWORDITEM N/P OLD INT INST DISP
12 91 35–69926–0005 1 Harness
92 35–69927–0005 1 Harness
93 35–69968–0007 1 Harness
94 35–69967–0007 1 Harness
20 CAN68251–8–33
SNA
2 Connctr
30 M85049/52–1–8N 4 Bckshll
40 NAS1149DN416H 16 Washer
50 MS21042–04 16 Nut
60 NAS1101–04–6 16 Screw
70 35–69771–0201 4 Support
80 MS20470AD4–5 12 Rivet
110 CAN68251–8–98
SNA
2 Connctr
120 NAS1801–3–12 4 Screw
130 MS35650–302 4 Nut
140 NAS679A3W 4 Nut
150 MS35338–43 8 Washer
160 NAS1149D0332J 12 Washer
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 9

### Page 10

CN-235 - SERVICE BULLETIN
FIG ITEM N/P NEW QTY UM KEYWORDITEM N/P OLD INT INST DISP
200 AS21919WDG04 2 Clamp
201 NAS1801–3–10 2 Screw
202 NAS679A3 2 Nut
203 NAS1149D0316H 2 Washer
300 35–A3349–0001 1 Labels
Set
SB235260005K07
FIG ITEM N/P NEW QTY UM KEYWORDITEM N/P OLD INT INST DISP
14 91 35–69926–0005 1 Harness 35–69926–00 03 1
92 35–69927–0005 1 Harness 35–69927–00 03 1
93 35–69968–0007 1 Harness 35–69968–00 03 1
94 35–69967–0007 1 Harness 35–69967–00 03 1
20 CAN68251–8–33
SNA
2 Connctr
40 NAS1149DN416H 16 Washer
50 MS21042–04 16 Nut
60 NAS1101–04–6 16 Screw
110 CAN68251–8–98
SNA
2 Connctr
NOTE : INT 03 – Not interchangeable
NOTE : INST DISP 1 – Discard
D. LIST OF MATERIALS - OPERATOR SUPPLIED
(1) Consumable Materials
DESCRIPTION REFERENCE TO CML QTY PER A/C INST DISP
MAT No.
Sealant Mat. No. AIMS
04–05–014A/-015A
As required
Sealant Mat. No. AIMS
04–05–014B/-015B
As required
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 10

### Page 11

CN-235 - SERVICE BULLETIN
DESCRIPTION REFERENCE TO CML QTY PER A/C INST DISP
MAT No.
Varnish Mat. No. Z-12.402 As required
NOTE : To accomplish this Service Bulletin it is also necessary to use
the consumable parts listed in the referenced manuals.
(2) Components
None
E. PARTS TO BE RE-IDENTIFIED BY THE OPERATOR
None
F. TOOLING - PRICE AND AVAILABILITY
None
G. SPECIAL TOOLS
None
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 11

### Page 12

CN-235 - SERVICE BULLETIN
INTENTIONALLY LEFT BLANK
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 12

### Page 13

CN-235 - SERVICE BULLETIN
3. ACCOMPLISHMENT INSTRUCTIONS
WARNING: Make sure all warning indications are respected in the refer ence
procedures.
A. GENERAL
(1) Preparation
NOTE : All the dimensions shown herein are in millimeters, unless
otherwise specified.
(a) Prepare the aircraft for the work and obey all the safety
precautions.
(b) Put warning notices in position to show personnel that
maintenance tasks are in progress.
(c) Disconnect all the electrical power supplies and make su re
that all the corresponding electrical circuits are isolate d.
(d) Put the maintenance platforms in position.
(e) Prepare the consumable material necessary to do the work .
(f) Put warning notices in position to prevent the supply of
electrical power to the aircraft.
(2) Standard Practices
(a) Standard Torques. Refer to AMM 20-21-00.
(b) Electrical Bonding. Refer to AMM 20-28-00.
(c) Sealing. Refer to AMM 20-38-00.
(d) Fasteners Removal/Installation Metallic Structure. R efer
to SRM 51-41-00.
(e) Electrical Wiring and Bundles. Refer to AMM 20-27-00.
(f) Surface Treatment. Refer to AMM 20-50-00.
(3) Work Breakdown
ON AIRCRAFT
EFFECTIVITY: ALL
- Put the aircraft in the safe condition for maintenance task s.
- Get access to the work area.
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 13

### Page 14

CN-235 - SERVICE BULLETIN
EFFECTIVITY: SM01 and L303 if SB–235–26–0004 has not been ac com-
plished.
- Remove the Fire Extinguisher Cylinders WB5 (WB6).
- Connectors zone WB13M/WB13H (WB10M/WB10H):
. Replace harnesses between the connectors zone and the bott le.
- Connectors zone WB15M/WB15H (WB14M/WB14H):
. Re-locate installed bonding points.
. Install supports for the connectors zones.
. Connect and install the receptacle, WB15H (WH14H).
. Install new harnesses with the plug, WB15M (WB14M).
- Install the Fire Extinguisher Cylinders WB5 (WB6).
EFFECTIVITY: AE01, AE02, IB01, IB02, L302 and QC02 if
SB–235–26–0004 has not been accomplished.
- Remove the Fire Extinguisher Cylinders WB5 (WB6).
- Connectors zone WB13M/WB13H (WB10M/WB10H):
. Install new bonding points.
. Install supports for the connectors zones.
. Install clamps.
. Re-identify installed wires (except versions AE01, AE02 a nd
L302).
. Connect and install the receptacle, WB13H (WH10H).
. Install new harnesses with the plug, WB13M (WB10M).
- Connectors zone WB15M/WB15H (WB14M/WB14H):
. Re-locate installed bonding points.
. Install supports for the connectors zones.
. Connect and install the receptacle, WB15H (WH14H).
. Install new harnesses with the plug, WB15M (WB14M).
- Install the Fire Extinguisher Cylinders WB5 (WB6).
EFFECTIVITY: AE01, AE02, IB01, IB02, L302, L303, SM01 and QC 02
with SB–235–26–0004 accomplished.
- Remove and discard installed harness between the connecto rs
zone and the bottle.
- Disconnect and discard installed plug.
- Connect and install the receptacle.
- Install new harnesses with the plug.
EFFECTIVITY: ALL
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 14

### Page 15

CN-235 - SERVICE BULLETIN
- Do tests.
- Close the access panels.
- Record the accomplishment.
B. MODIFICATION
NOTE : The item numbers referred to in this paragraph correspond t o
those given in the kits and to the different illustrations.
NOTE : Do the surface protection standard practice on the drill ho les
you make.
NOTE : The symbolic identifications will be done with the labels s et
(300) supplied in the kits.
(1) Preliminary Operations
(a) De-energize the aircraft electrical system and disconn ect
the GPU. Refer to AMM 24-40-00.
(b) Do the preliminary operations described in AMM 26-21-11.
(2) Removal.
(a) Remove and keep panel 931AT. Refer to AMM 06-41-57.
(b) EFFECTIVITY: AE01, AE02, IB01, IB02, L302, L303, SM01 an d
QC02 if SB–235–26–0004 has not been accomplished.
Remove and keep the Fire Extinguisher Cylinder WB5 (WB6).
Refer to AMM 26-21-11.
(3) Mechanical Modification.
(a) EFFECTIVITY: SM01 and L303 if SB–235–26–0004 has not bee n
accomplished.
Kit SB235260005K03. Refer to Figure 6.
1 Connectors zone WB15M/WB15H (WB14M/WB14H). Refer to
Figure 6, views B and D.
a Remove the bonding points ZM4–143 (ZM4–142) from the
profiles of the extinguisher support.
Discard the attaching parts and keep the wires.
b Install 2 supports (70).
- Position the new supports (70) at the measurements
shown in the illustration.
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 15

### Page 16

CN-235 - SERVICE BULLETIN
- Transfer the drill holes from the new supports (70)
to the extinguisher supports (1) at between 3.25 and
3.35 diameter.
- Install the new supports (70) on the extinguisher
supports (1) with 3 rivets (80).
c Install bonding points ZM4–143 (ZM4–142) in their
new location at the measurements shown in the
illustration.
Refer to AMM 20-28-00.
- Make drill holes at the positions shown in the
illustration at between 4.813 and 4.833 diameter.
- Use new screws (120), new nuts (130) and (140), new
washers (150) and (160) and the wires that you kept
before.
- Identify new bonding points.
2 Install the Fire Extinguisher Cylinders WB5 (WB6) that
you kept before.
Refer to AMM 26-21-11.
(b) EFFECTIVITY: AE01, AE02, IB01, IB02, L302 and QC02 if
SB–235–26–0004 has not been accomplished.
Kit SB235260005K04 and SB235260005K05. Refer to Figure 7.
1 Connectors zone WB13M/WB13H (WB10M/WB10H). Refer to
Figure 7, views D and E.
a Install 2 supports (70).
- Position the new supports (70) at the measurements
shown in the illustration.
- Transfer the drill holes from the new supports (70)
to the extinguisher supports (1) at between 3.25 and
3.35 diameter.
- Install the new supports (70) on the extinguisher
supports (1) with 3 rivets (80).
b Install clamps (200):
- Make a drill hole of between 4.813 and 4.833 in the
position shown in the illustration.
- Install the clamps (200) on the extinguisher support
(1) with screws (201), nuts (202) and washers (203).
c Install the bonding points ZM4–149 (ZM4–148) in
their new location at the measurements shown in the
illustration.
Refer to AMM 20-28-00.
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 16

### Page 17

CN-235 - SERVICE BULLETIN
- Make drill holes at the positions shown in the
illustration at between 4.813 and 4.833 diameter.
- Use new screws (120), new nuts (130) and (140), new
washers (150) and (160) and the wires that you kept
before.
- Identify new bonding points.
2 Connectors zone WB15M/WB15H (WB14M/WB14H). Refer to
Figure 7, views B and C.
a Remove the bonding points ZM4–143 (ZM4–142) from the
profiles of the extinguisher support.
Discard the attaching parts and keep the wires.
b Install 2 supports (70).
- Position the new supports (70) at the measurements
shown in the illustration.
- Transfer the drill holes from the new supports (70)
to the extinguisher supports (1) at between 3.25 and
3.35 diameter.
- Install the new supports (70) on the extinguisher
supports (1) with 3 rivets (80).
c Install bonding points ZM4–143 (ZM4–142) in their
new location at the measurements shown in the
illustration.
Refer to AMM 20-28-00.
- Make drill holes at the positions shown in the
illustration at between 4.813 and 4.833 diameter.
- Use new screws (120), new nuts (130) and (140), new
washers (150) and (160) and the wires that you kept
before.
- Identify new bonding points.
3 Install the Fire Extinguisher Cylinders WB5 (WB6) that
you kept before.
Refer to AMM 26-21-11.
(4) Electrical Modification.
(a) EFFECTIVITY: SM01 and L303 if SB–235–26–0004 has not bee n
accomplished.
Kit SB235260005K03. Refer to Figure 6.
1 Connectors zone WB13M/WB13H (WB10M/WB10H).
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 17

### Page 18

CN-235 - SERVICE BULLETIN
a Replace the installed harnesses between connectors
zone WB13M (WB10M) and the cartridges, with harnesses
(93) and (94).
NOTE : Make sure with a multimeter (before you do the
connection of harness (93)) that the voltage
between positive and negative wire is 28VDC
when you turn left the left Fire Handle lever
of Control Unit ZD123, in the Overhead Panel,
to simulate a direct discharge.
NOTE : Make sure with a multimeter (before you do the
connection of harness (94)) that the voltage
between positive and negative wire is 28VDC
when you turn right the left Fire Handle lever
of Control Unit ZD123, in the Overhead Panel,
to simulate a cross discharge.
2 Connectors zone WB15M/WB15H (WB14M/WB14H).
a Find the wires shown that you disconnected before from
the extinguisher support.
Cut to the correct length to reach the new connectors
zone WB15H (WB14H).
Refer to Figure 1.
b Crimp the new contacts to the wires and connect
them to the new connectors WB15H (WB14H) (110) with
backshell (30).
c Install the receptacle WB15H (WB14H) (110) with 4
washers (40), 4 nuts (50), and 4 screws (60) in each
connectors zone.
Make bonding points as shown in the referenced
procedures. Apply sealants AIMS 04–05–014A/-015A and
AIMS 04–05–014B/-015B and varnish Z-12.402.
d Install harnesses (91) and (92).
- Connect the end of the plug WB15M (WB14M) in the new
connectors zone.
- Connect the end of harness (91) to cartridge 2 of
bottle WB5. Refer to Figure 1 and Figure 9.
NOTE : Make sure with a multimeter (before you do
the connection) that the voltage between
positive and negative wire is 28VDC when you
turn right the right Fire Handle lever of
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 18

### Page 19

CN-235 - SERVICE BULLETIN
Control Unit ZD123, in the Overhead Panel, to
simulate a cross discharge.
- Connect the end of harness (92) to cartridge 1 of
bottle WB6. Refer to Figure 1 and Figure 9.
NOTE : Make sure with a multimeter (before you do
the connection) that the voltage between
positive and negative wire is 28VDC when you
turn left the right Fire Handle lever of
Control Unit ZD123, in the Overhead Panel, to
simulate a direct discharge.
e Identify the new connectors zone.
(b) EFFECTIVITY: IB01, IB02 and QC02 if SB–235–26–0004 has n ot
been accomplished.
Kit SB235260005K04. Refer to Figure 7.
1 Connectors zone WB13M/WB13H (WB10M/WB10H).
a Find the wires shown that you disconnected before from
the extinguisher support.
Cut to the correct length to reach the new connectors
zone WB13H (WB10H).
Refer to Figure 3.
b Re-identify installed wires as shown in the
illustration.
Use a sleeve (330).
Refer to Figure 3
c Crimp the new contacts to the wires and connect
them to the new connectors WB13H (WB10H) (20) with
backshell (30).
d Install the receptacle WB13H (WB10H) (20) with 4
washers (40), 4 nuts (50), and 4 screws (60) in each
connectors zone.
Make bonding points as shown in the referenced
procedures. Apply sealants AIMS 04–05–014A/-015A and
AIMS 04–05–014B/-015B and varnish Z-12.402.
e Lead the harnesses through the new clamps (200) that
you installed before.
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 19

### Page 20

CN-235 - SERVICE BULLETIN
f Install harnesses (93) and (94).
- Connect the end of the plug WB13M (WB10M) in the new
connectors zone.
- Connect the end of WB5 (WB6) to the corresponding
cartridge. Refer to Figure 3.
NOTE : Make sure with a multimeter (before you do
the connection of harness (93)) that the
voltage between positive and negative wire is
28VDC when you turn left the left Fire Handle
lever of Control Unit ZD123, in the Overhead
Panel, to simulate a direct discharge.
NOTE : Make sure with a multimeter (before you
do the connection of harness (94)) that
the voltage between positive and negative
wire is 28VDC when you turn right the left
Fire Handle lever of Control Unit ZD123,
in the Overhead Panel, to simulate a cross
discharge.
g Identify the new connectors zone.
2 Connectors zone WB15M/WB15H (WB14M/WB14H).
a Find the wires shown that you disconnected before from
the extinguisher support.
Cut to the correct length to reach the new connectors
zone WB15H (WB14H).
Refer to Figure 3.
b Crimp the new contacts to the wires and connect
them to the new connectors WB15H (WB14H) (110) with
backshell (30).
c Install the receptacle WB15H (WB14H) (110) with 4
washers (40), 4 nuts (50), and 4 screws (60) in each
connectors zone.
Make bonding points as shown in the referenced
procedures. Apply sealants AIMS 04–05–014A/-015A and
AIMS 04–05–014B/-015B and varnish Z-12.402.
d Install harnesses (91) and (92).
- Connect the end of the plug WB15M (WB14M) in the new
connectors zone.
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 20

### Page 21

CN-235 - SERVICE BULLETIN
- Connect the end of harness (91) to cartridge 2 of
bottle WB5. Refer to Figure 3 and Figure 9.
NOTE : Make sure with a multimeter (before you do
the connection) that the voltage between
positive and negative wire is 28VDC when you
turn right the right Fire Handle lever of
Control Unit ZD123, in the Overhead Panel, to
simulate a cross discharge.
- Connect the end of harness (92) to cartridge 1 of
bottle WB6. Refer to Figure 3 and Figure 9.
NOTE : Make sure with a multimeter (before you do
the connection) that the voltage between
positive and negative wire is 28VDC when you
turn left the right Fire Handle lever of
Control Unit ZD123, in the Overhead Panel, to
simulate a direct discharge.
e Identify the new connectors zone.
(c) EFFECTIVITY: AE01, AE02 and L302 if SB–235–26–0004 has n ot
been accomplished.
Kit SB235260005K05. Refer to Figure 7.
1 Connectors zone WB13M/WB13H (WB10M/WB10H).
a Find the wires shown that you disconnected before from
the extinguisher support.
Cut to the correct length to reach the new connectors
zone WB13H (WB10H).
Refer to Figure 2.
b Crimp the new contacts to the wires and connect
them to the new connectors WB13H (WB10H) (20) with
backshell (30).
c Install the receptacle WB13H (WB10H) (20) with 4
washers (40), 4 nuts (50), and 4 screws (60) in each
connectors zone.
Make bonding points as shown in the referenced
procedures. Apply sealants AIMS 04–05–014A/-015A and
AIMS 04–05–014B/-015B and varnish Z-12.402.
d Lead the harnesses through the new clamps (200) that
you installed before.
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 21

### Page 22

CN-235 - SERVICE BULLETIN
e Install harnesses (93) and (94).
- Connect the end of the plug WB13M (WB10M) in the new
connectors zone.
- Connect the end of WB5 (WB6) to the corresponding
cartridge. Refer to Figure 2.
NOTE : Make sure with a multimeter (before you do
the connection of harness (93)) that the
voltage between positive and negative wire is
28VDC when you turn left the left Fire Handle
lever of Control Unit ZD123, in the Overhead
Panel, to simulate a direct discharge.
NOTE : Make sure with a multimeter (before you
do the connection of harness (94)) that
the voltage between positive and negative
wire is 28VDC when you turn right the left
Fire Handle lever of Control Unit ZD123,
in the Overhead Panel, to simulate a cross
discharge.
f Identify the new connectors zone.
2 Connectors zone WB15M/WB15H (WB14M/WB14H).
a Find the wires shown that you disconnected before from
the extinguisher support.
Cut to the correct length to reach the new connectors
zone WB15H (WB14H).
Refer to Figure 2.
b Crimp the new contacts to the wires and connect
them to the new connectors WB15H (WB14H) (110) with
backshell (30).
c Install the receptacle WB15H (WB14H) (110) with 4
washers (40), 4 nuts (50) and 4 screws (60) in each
connectors zone.
Make bonding points as shown in the referenced
procedures. Apply sealants AIMS 04–05–014A/-015A and
AIMS 04–05–014B/-015B and varnish Z-12.402.
d Install harnesses (91) and (92).
- Connect the end of the plug WB15M (WB14M) in the new
connectors zone.
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 22

### Page 23

CN-235 - SERVICE BULLETIN
- Connect the end of harness (91) to cartridge 2 of
bottle WB5. Refer to Figure 2 and Figure 9.
NOTE : Make sure with a multimeter (before you do
the connection) that the voltage between
positive and negative wire is 28VDC when you
turn right the right Fire Handle lever of
Control Unit ZD123, in the Overhead Panel, to
simulate a cross discharge.
- Connect the end of harness (92) to cartridge 1 of
bottle WB6. Refer to Figure 2 and Figure 9.
NOTE : Make sure with a multimeter (before you do
the connection) that the voltage between
positive and negative wire is 28VDC when you
turn left the right Fire Handle lever of
Control Unit ZD123, in the Overhead Panel, to
simulate a direct discharge.
e Identify the new connectors zone.
(d) EFFECTIVITY: AE01, AE02, IB01, IB02, L302, L303, SM01 an d
QC02 with SB–235–26–0004 accomplished.
Kit SB235260005K07. Refer to Figure 8.
1 Connectors zone WB13M/WB13H (WB10M/WB10H).
a Disconnect plug WB13M (WB10M) and receptacle WB13H
(WB10H).
b Remove and discard the attaching parts (41), (51) and
(61).
c Connect the installed wires, with reference to Figure
4 and Figure 5 in the new connector WB13H (WB10H)
(20).
d Remove and discard installed harness WB13M (WB10M) and
the cartridge of the bottle.
e Install the receptacle WB13H (WB10H) (20) in the
connectors zone with 4 washers (40), 4 nuts (50) and 4
screws (60) in each connectors zone.
Make bonding points as shown in the referenced
procedures. Apply sealants AIMS 04–05–014A/-015A and
AIMS 04–05–014B/-015B and varnish Z-12.402.
f Install harnesses (93) and (94).
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 23

### Page 24

CN-235 - SERVICE BULLETIN
- Connect the end of the plug WB13M (WB10M) in the new
connectors zone.
- Connect the end of WB5 (WB6) to the corresponding
cartridge. Refer to Figure 4 and Figure 5.
NOTE : Make sure with a multimeter (before you do
the connection of harness (93)) that the
voltage between positive and negative wire is
28VDC when you turn left the left Fire Handle
lever of Control Unit ZD123, in the Overhead
Panel, to simulate a direct discharge.
NOTE : Make sure with a multimeter (before you
do the connection of harness (94)) that
the voltage between positive and negative
wire is 28VDC when you turn right the left
Fire Handle lever of Control Unit ZD123,
in the Overhead Panel, to simulate a cross
discharge.
g Identify the new connectors zone.
2 Connectors zone WB15M/WB15H (WB14M/WB14H).
a Disconnect plug WB15M (WB14M) and receptacle WB15H
(WB14H).
b Remove and discard the attaching parts (41), (51) and
(61).
c Connect the installed wires, with reference to Figure
4 and Figure 5 in the new connector WB15H (WB14H)
(110).
d Remove and discard installed harness WB15M (WB14M) and
the cartridge of the bottle.
e Install the receptacle WB15H (WB14H) (110) in the
connectors zone with 4 washers (40), 4 nuts (50) and 4
screws (60) in each connectors zone.
Make bonding points as shown in the referenced
procedures. Apply sealants AIMS 04–05–014A/-015A and
AIMS 04–05–014B/-015B and varnish Z-12.402.
f Install harnesses (91) and (92).
- Connect the end of the plug WB15M (WB14M) in the new
connectors zone.
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 24

### Page 25

CN-235 - SERVICE BULLETIN
- Connect the end of harness (91) to cartridge 2 of
bottle WB5. Refer to Figure 4 , Figure 5 and Figure
9.
NOTE : Make sure with a multimeter (before you do
the connection) that the voltage between
positive and negative wire is 28VDC when you
turn right the right Fire Handle lever of
Control Unit ZD123, in the Overhead Panel, to
simulate a cross discharge.
- Connect the end of harness (92) to cartridge 1 of
bottle WB6. Refer to Figure 4 , Figure 5 and Figure
9.
NOTE : Make sure with a multimeter (before you do
the connection) that the voltage between
positive and negative wire is 28VDC when you
turn left the right Fire Handle lever of
Control Unit ZD123, in the Overhead Panel, to
simulate a direct discharge.
g Identify the new connectors zone.
(5) Installation.
(a) Install panel 931AT that you kept before. Refer to AMM
06-41-57.
C. TEST
(1) Do electrical continuity checks on the new or modified wi res.
(2) Connect the GPU and energize the aircraft electrical sys tem.
Refer to AMM 24-40-00.
(3) Do the tests described in AMM 26-21-11.
D. CLOSE UP
(1) Do the close up operations described in AMM 26-21-11.
(2) Remove all the tools and equipment from the work area. Mak e sure
that the work area is clean.
(3) Remove the warning notices.
(4) Make sure that all the tools and equipment have been remov ed from
the area around the aircraft.
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 25

### Page 26

CN-235 - SERVICE BULLETIN
E. DOCUMENTATION
Write in the applicable aircraft records that you have done a ll the
work given in this Service Bulletin.
F. FIGURES
See next page/s.
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 26

### Page 27 (OCR)

AS
CN-235 - SERVICE BULLETIN
69967  2WB7B20  AUTO FIRE  EXTINGUISHING  WB6А*
WB6  2WB31A20N
2WB34A20N  ZM4-142
WB 10M
WB 10H  2WB16C20  # 2WB14C20
2WB7A20N  2WB6A20N  2WB16C20  2WB14C20  69775
69775  69775
2M
ZM4-148  ZM4-142
ZM4-149  ZM4-143
1WB14C20  1WB16C20
69774  (69774
(69774)
WB13H  1WB6A20N  1WB 14A20  1WB7A20N  /// 1WB16C20
WB 13M  1WB14D20XXX  AUTO FIRE  EXTINGUISHING  WB5  GND  ~  WB5A*  1WB31A20N
SB 260005 1 0102 01 00  69968  1WB6B20  1WB34A20N  > ZM4-143
- Xxx
XXX
BEFORE
EXISTING WIRE
/ WIRE TO BE MODIFIED
XXX WIRE TO BE REMOVED
ONLY ILLUSTRATED AFFECTED WIRES
~
Figure 1. Modification of the Engine Fire Extinguisher Circuit (WB).
Effectivity: L303 and SM01 if SB-235-26-0004 has not been accomplished.
Date: Jul 09/2014  SB -235-26-0005
Original  Pag : 27

### Page 28 (OCR)

EACASA
CN-235 - SERVICE BULLETIN
WB6A*
2WB31A2ON  2M
2WB34A2ON  2M
q11 ZM4-142
WB6
(69967
2WB7B20  - 69927  69775
WB1OM  WB14M
WB10H  WB14H
2M  2WB14C20
2M  2WB16C20
2M 2WB7A2ON
ZM4-148  ZM4-142
ZM4-149  ZM4-143
1WB6A20N  1WB7A2ON
_ 1M  1WB14C20
1M  1WB16C20
WB13H  WB15H
WB13M  WB15M  69774
1WB6B20  4020  69926
1M
C SB 260005 1 0102 02 00  WB5A*
1WB31A20N  I di: 2M4-143
1WB34A20N
WB5
69968
AFTER
-NEW WIRE
/// MODIFIED WIRE
- EXISTING WIRE
ONLY ILLUSTRATED AFFECTED WIRES
Figure 1. Modification of the Engine Fire Extinguisher Circuit (WB). (Sheet
2 of 2)
Effectivity:  L303 and SM01 if SB-235-26-0004 has not been accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 28

### Page 29 (OCR)

EADS
CASA
CN-235 - SERVICE BULLETIN
ZM4-142  ZM4-142  ZM4-142
2W  2WB3  2WB34A  2WB
69775  -69775
WB6
AUTO FIRE EXTING.
CENTRAL WING
CENTRAL WING
AUTO FIRE EXTING.
WB5
69774  69774
SB 260005 1 0202 01 00  ZM4-143  ZM4-143  ZM4-143
_ _
EXISTING WIRE
MY WIRE TO BE MODIFIED
ONLY ILLUSTRATED AFFECTED WIRES  BEFORE
Figure 2. Modification of the Engine Fire Extinguisher Circuit (WB).
Effectivity: AE01, AE02 and L302 if SB-235-26-0004 has not been
accomplished.
Date: Jul 09/2014  SB -235-26-0005
Original  Pag : 29

### Page 30 (OCR)

EADS
CASA
CN-235 - SERVICE BULLETIN
WB6A*
2WB31A2ON
2WB34A20N  ZM4-142
WB6
69967
2WB7B20  2WB16D20  69927
WB10M  WB14M
WB10H  WB14H  2M  2WB14C20
2M  2WB16C20
69775  69775
2M 2WB7A20N  2WB6A20N
2M
ZM4-148  ZM4-142
ZM4-149  ZM4-143
1M
69774)
1M  1WB14C20
1WB16C20
WB13H  WB15H  69774
WB13M  WB15M
1WB6B20  1WB16F20  69926
SB 260005 1 0202 02 00  WB5A*
1WB31A20N  1M d''
1WB34A20N  ZM4-143
WB5
69968
EXISTING WIRE
NEW WIRE
/ MODIFIED WIRE
ONLY ILLUSTRATED AFFECTED WIRES  AFTER
Figure 2. Modification of the Engine Fire Extinguisher Circuit (WB). (Sheet
2 of 2)
Effectivity: AE01, AE02 and L302 if SB-235-26-0004 has not been
accomplished.
Date: Jul 09/2014  SB -235-26-0005
Original  Pag : 30

### Page 31 (OCR)

EADS
CASA
CN-235 - SERVICE BULLETIN
CENTRAL WING
63713)
AUTO FIRE EXTING.
WB6  oft.  2WB7A2ON  2M d1: ZM4-142
2WB 16D20  2M
2WB14D20  2M
2WB6A2ON  2 d1: ZM4-142
63713
2WB16D20
ZC11232-22M
ZC11232-21M
CENTRAL WING  1WB16D20  1WB14D20
AUTO FIRE EXTING.  63710
WB5  1WB7 A20N  1M dliZM4-143
1WB16D20  1M
1WB14D20  1M
81270771  1WB6A20N  IM dl:ZM4-143
63710
C SB 260005 1 0302 01 00  > WIRE TO BE RE-IDENTIFIED
// WIRE TO BE MODIFIED
ONLY ILLUSTRATED AFFECTED WIRES
BEFORE
Figure 3. Modification of the Engine Fire Extinguisher Circuit (WB).
Effectivity: IB01, IB02 and QC02 if SB-235-26-0004 has not been
accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 31

### Page 32 (OCR)

EACASA
CN-235 - SERVICE BULLETIN
WB6
69967
69927)
2WB14E20
WB10M  WB14M
63713)
WB10H  WB14H  2M  2WB14D20
2M  2WB16DD20
•1p 2M ZWB7AZON  2M 2WB6A20N
ZC11232-22M
ZM4-148  ZM4-142
ZM4-149  ZM4-143
ZC11232-21M
1WB7A2ON
1WB14DD20
1WB16D20
WB13H  WB15H  63710
WB13M  WB15M
1M 1WB6B20  1WB14D20  1WB7B20  69926
SB 260005 1 0302 02 00  WB5
69968  -----
RE-IDENTIFIED WIRE
NEW WIRE
ONLY ILLUSTRATED AFFECTED WIRES  / MODIFIED WIRE  AFTER
Figure 3. Modification of the Engine Fire Extinguisher Circuit (WB). (Sheet
2 of 2)
Effectivity: IB01, IB02 and QC02 if SB-235-26-0004 has not been
accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 32

### Page 33 (OCR)

AS
CN-235 - SERVICE BULLETIN
WB6А*
2WB31 A20N  2N di: 2M4-142
2WB34A2ON
WB6
69967  2WB16D20  2WB14E201 2M  69927
WB10M  WB14M
WB10H  WB14H
= KA  2WB14C20
2WB16C20
69775  69775
2WB7A20N
ZM4-148  ZM4-142
ZM4-149  ZM4-143
1WB6A20N  1WB7A20N
69774  1M  1WB14C20
1M  1WB16C20
WB13H  WB15H  69774
WB13M  WB15M
SB 260005 1 0402 01 00  1WB6B20  1WB14D20  69926  WB5А*
1WB34A2ON  1WB31A2ON 1M  IM JI: ZM4-143
WB5
69968
EXISTING WIRE
XXX WIRE TO BE REMOVED
/ WIRE TO BE MODIFIED
ONLY ILLUSTRATED AFFECTED WIRES  BEFORE
Figure 4. Modification of the Engine Fire Extinguisher Circuit (WB).
Effectivity: AE01, AE02, L302, L303 and SM01 with SB-235-26-0004
accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 33

### Page 34 (OCR)

EADS
CASA
CN-235 - SERVICE BULLETIN
WB6A*
2WB31A2ON  IN di: 2M4-142
2WB34A2ON
69967  2M
69927)
2WB7B20  2WB14E20
WB10M  WB14M
WB10H  WB14H  2M  2WB14C20
2M  2WB16C20
69775  69775)
2M 2WB7A20N  2M 2WB6A2ON
ZM4-148  ZM4-142
ZM4-149  ZM4-143
1WB6A20N
69774)
1M  1WB14C20
1WB16C20
WB13H  WB15H  69774
WB13M  WB15M
1WB7B20  1WB16F20
SB 260005 1 0402 02 00  69926  WB5А*
1WB31A2ON  1M
1WB34A20N  di: ZM4-143
WB5
69968
EXISTING WIRE
NEW WIRE
// MODIFIED WIRE
ONLY ILLUSTRATED AFFECTED WIRES  AFTER
Figure 4. Modification of the Engine Fire Extinguisher Circuit (WB). (Sheet
2 of 2)
Effectivity: AE01, AE02, L302, L303 and SM01 with SB-235-26-0004
accomplished.
Date: Jul 09/2014  SB -235-26-0005
Original  Pag : 34

### Page 35 (OCR)

EADS '
CASA
CN-235 - SERVICE BULLETIN
WB6
69967
2WB7B20  (69927
WB10M  WB14M  (63713
WB10H  WB14H
2M 2WB14D20
2M 2WB16DD20
ZM4-148  ZM4-142
ZM4-149  ZM4-143
1WB7A20N
1M  1WB14DD20
1WB16D20
63710
WB13H  WB15H
WB13M  WB15M
SB 260005 1 0502 01 00  WB5
69968
ХХХ WIRE TO BE REMOVED
// WIRE TO BE MODIFIED
ONLY ILLUSTRATED AFFECTED WIRES  BEFORE
Figure 5. Modification of the Engine Fire Extinguisher Circuit (WB).
Effectivity: IB01, IB02 and QC02 with SB-235-26-0004 accomplished.
Date: Jul 09/2014  SB -235-26-0005
Original  Pag : 35

### Page 36 (OCR)

EADS '
CASA
CN-235 - SERVICE BULLETIN
WB6  GND
69967
2WB7B20  2WB16D20  69927
WB10M  WB14M  63713
WB10H  WB14H
2M  2WB14D20
2M 2WB16DD20
2M 2WB7A2ON  2WB6A20N
ZM4-148  ZM4-142
ZM4-149  ZM4-143
1WB6A2ON  1WB7A2ON
¡ 1M  1WB14DD20
1M  1WB16D20
WB13H  WB15H  63710)
WB13M  WB15M
1WR14020  1WB7B20  1WB16F20
69926
SB 260005 1 0502 02 00  WB5
69968
NEW WIRE
// MODIFIED WIRE
ONLY ILLUSTRATED AFFECTED WIRES  AFTER
Figure 5. Modification of the Engine Fire Extinguisher Circuit (WB). (Sheet
2 of 2)
Effectivity: IB01, IB02 and QC02 with SB-235-26-0004 accomplished.
Date: Jul 09/2014  SB -235-26-0005
Original  Pag : 36

### Page 37 (OCR)

EADS '
CASA
CN-235 - SERVICE BULLETIN
STA 11486
WB6
C SB 260005 1 0604 01 00  35-69774-00  c  35-69775-00
BEFORE
Figure 6.  Modification of the electrical installation.
Effectivity: L303 and SM01 if SB-235-26-0004 has not been accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 37

### Page 38 (OCR)

EADS
CASA
CN-235 - SERVICE BULLETIN
C
ZM4-149
WB13M
35-69968-0001
ZM4-143
WB13H
35-69774-00
35-69774-00
E
35-69967-0001
ZM4-148
WB10M
ZM4-142
WB10H
35-69775-00
C SB 260005 1 0604 02 00  35-69775-00
41
51 > (4 PLACES)
61
BEFORE
Figure 6. Modification of the electrical installation. (Sheet 2 of 4)
Effectivity: L303 and SM01 if SB-235-26-0004 has not been accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 38

### Page 39 (OCR)

EADS '
CASA
CN-235 - SERVICE BULLETIN
C
120
130
140
150  <2  PLACES)
160  (3 PLACES)
ZM4-143  ZM4-149
WB15M  WB13M
- 93
WB15H  WB13H
110
30
40
50  >(4 PLACES)
60
G
C SB 260005 1 0604 03 00  ELECTRICAL BONDING  NUMBER OF
(CONTACT POINTS)
SEE AMM 20-28-00
›INSTALL NEW SUPPORT (70).
› EXISTING SUPPORT.
AFTER
Figure 6. Modification of the electrical installation. (Sheet 3 of 4)
Effectivity: L303 and SM01 if SB-235-26-0004 has not been accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 39

### Page 40 (OCR)

EADS
CASA
CN-235 - SERVICE BULLETIN
-120
130
140
(E) (E)
150 (2 PLACES)
160 (3 PLACES)
ZM4-148
WB10M  ZM4-142
92  WB14M
WB10H
WB14H
110
30
70
DIAMETER
HOLE  ITEM  REMARKS
MIN.  MAX.  NUMBER OF
ELECTRICAL BONDING
C SB 260005 1 0604 04 00  80  4.8134.833  3.25  3.35  N/A  (CONTACT POINTS)  AMM 20-28-00
INSTALL NEW SUPPORT (70).
EXISTING SUPPORT.
› TRANSFER DRILL HOLE FROM THE SUPPORT (70) TO THE STRUCTURE.
RIVET HEAD ON SHOWN SIDE.
AFTER
Figure 6.  Modification of the electrical installation.  (Sheet 4 of 4)
Effectivity: L303 and SM01 if SB-235-26-0004 has not been accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 40

### Page 41 (OCR)

EADS
CASA
CN-235 - SERVICE BULLETIN
STA 11486
A
C
WB5  WB6
35-69775-00
35-69774-00
35-63713-00
35-63710-00
ZM4-143  ZM4-142
C SB 260005 1 0703 01 00  35-69774-00  35-69775-00
35-63710-00  35-63713-00
EFFECTIVITY IB01, IBO2, QCO2.
EFFECTIVITY AE01, AE02, L302.
BEFORE
Figure 7. Modification of the electrical installation.
Effectivity: AE01, AE02, IB01, IB02, L302 and QC02 if SB-235-26-0004 has
not been accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 41

### Page 42 (OCR)

EADS
CASA
CN-235 - SERVICE BULLETIN
B
WB5  WB6
E
35-69774-00
35-69775-00
35-63710-00
35-63713-00
120
130
120(  140  (=) (=)
(2 PLACES)  150
130
140  (3 PLACES)  160
(=) (=)
150  (2 PLACES)
160  (3 PLACES)
ZM4-149  93
ZM4-143  150  WB13M
WB15M
WB13H
70
WB15H  20  30
110  201
30  202
203
C SB 260005 1 0703 02 00  NUMBER OF
ELECTRICAL BONDING
(CONTACT POINTS)
SEE AMM 20-28-00
EFFECTIVITY IB01, IBO2, QCO2.
EFFECTIVITY AE01, AE02, L302.
AFTER
Figure 7. Modification of the electrical installation. (Sheet 2 of 3)
Effectivity: AE01, AE02, IB01, IB02, L302 and QC02 if SB-235-26-0004 has
not been accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 42

### Page 43 (OCR)

EADS
CASA
CN-235 - SERVICE BULLETIN
120-  C  -120
130  130
(=) (=)  140  140
150 (2 PLACES)  (=) (=)  150  (2 PLACES)
160 (3 PLACES)  160 (3 PLACES)
ZM4-148 G  - 92
WB10M  ZM4-142
WB14M
WB10H
WB14H
20
- 30  110
30
15  201
202
203
G
40
50  >(4 PLACES)
60
G
C SB 260005 1 0703 03 00  DIAMETER  10
HOLE  ITEM  REMARKS
MIN_ MAX.  NUMBER OF
80  3.25  3.35  ELECTRICAL BONDING  (CONTACT POINTS)
4.8134.833  N/A  AMM 20-28-00
TRANSFER DRILL HOLE FROM THE SUPPORT (70) TO THE STRUCTURE.
RIVET HEAD ON SHOWN SIDE.  AFTER
Figure 7. Modification of the electrical installation. (Sheet 3 of 3)
Effectivity: AE01, AE02, IB01, IB02, L302 and QC02 if SB-235-26-0004 has
not been accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 43

### Page 44 (OCR)

EADS '
CASA
CN-235 - SERVICE BULLETIN
STA 11486
B  c
WB5  WB6
D
35-69774-00  35-69775-00
35-63710-00  35-63713-00
C SB 260005 1 0803 01 00  EFFECTIVITY AE01, AE02, L302, L303, SM01.
EFFECTIVITY IB01, IBO2, QCO2.
Figure 8. Modification of the electrical installation.
Effectivity:  AE01, AE02, IB01, IB02, L302, L303, SM01 and QC02 with
SB-235-26-0004 accomplished.
Date: Jul 09/2014  SB -235-26-0005
Original  Pag : 44

### Page 45 (OCR)

EADS
CASA
CN-235 - SERVICE BULLETIN
35-69926-00  35-69968-00
ZM4-143  ZM4-149
WB15M  WB13M
WB15H  WB13H
E  C
G
35-69927-00
ZM4-148  ZM4-142
WB10M  WB14M
35-69967-00
WB10H  WB14H
G
C SB 260005 1 0803 02 00  > (4 PLACES)
61
BEFORE
Figure 8. Modification of the electrical installation. (Sheet 2 of 3)
Effectivity:  AE01, AE02, IB01, IB02, L302, L303, SM01 and QC02 with
SB-235-26-0004 accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 45

### Page 46 (OCR)

EADS
CASA
CN-235 - SERVICE BULLETIN
ZM4-143  ZM4-149
WB15M  WB13M
WB15H  WB13H
70
110  20
ZM4-148  92  ZM4-142
WB1OM  WB14M
WB10H  WB14H
- 20  • 110
C SB 260005 1 0803 03 00  ￾ 40
NUMBER OF  50 > (4 PLACES)
ELECTRICAL BONDING  60
(CONTACT POINTS)
SEE AMM 20-28-00
G
AFTER
Figure 8. Modification of the electrical installation. (Sheet 3 of 3)
Effectivity:  AE01, AE02, IB01, IB02, L302, L303, SM01 and QC02 with
SB-235-26-0004 accomplished.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 46

### Page 47 (OCR)

EADS '
CASA
CN-235 - SERVICE BULLETIN
DISCHARGE SCHEME
DIRECT DISCHARGE
B
CROSS DISCHARGE
C SB 260005 1 0902 01 00
Figure 9. Schematic of discharge of the fire extinguisher bottles.
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 47

### Page 48 (OCR)

EADS '
CASA
CN-235 - SERVICE BULLETIN
LEFT BOTTLE WB5
CARTRIDGE 1  CARTRIDGE 2
(TO LEFT ENGINE)  (TO RIGHT ENGINE)
POSITIVE
CONNECTOR 1
NEGATIVE
CONNECTOR 2
- NEGATIVE
CONNECTOR 1
POSITIVE
CONNECTOR 2
RIGHT BOTTLE WB6
CARTRIDGE 1  CARTRIDGE 2
(TO RIGHT ENGINE)  (TO LEFT ENGINE)
C SB 260005 1 0902 02 00  POSITIVE
CONNECTOR 1
NEGATIVE
CONNECTOR 2
- NEGATIVE
CONNECTOR 1
POSITIVE
CONNECTOR 2
Figure 9.  Schematic of discharge of the fire extinguisher bottles. (Sheet 2
of 2)
Date: Jul 09/2014  SB-235-26-0005
Original  Pag : 48

### Page 49

CN-235 - SERVICE BULLETIN
FIRE PROTECTION
ENGINE FIRE EXTINGUISHING. MODIFICATION OF THE HARNESS INSTALLATION IN THE
FIRE EXTINGUISHER BOTTLES.
REPORTING SHEET
Please complete the appropriate item (A or B):
A - SB WILL BE embodied ......................... YES/NO (if NO please
comment)
If YES, aircraft concerned (as per SB effectivity by default ) and planned
dates (month/year) of embodiement: .................... ......................
................................................... .........................
................................................... .........................
B - SB HAS BEEN embodied on aircraft: ................................ .......
................................................... .........................
................................................... .........................
Operator comments: .................................. ........................
................................................... .........................
................................................... .........................
From Airline: ....................................... ........................
Name/Title: ........................................ .........................
Signature:..................... Date: ............... ......
If operational documentation is affected (see Paragraph 1. K of this
SB): If information is needed prior to next normal revision or pri or to SB
embodiment, please indicate required service(s):
Either : Advance data ................................. YES/NO
Or : Intermediate/Temporary revision ..............YES/ NO
Important Information: This SB will only be incorporated in your maintenance
and operational documentation if this sheet is returned to E ADS-CASA(MTAD)
and signed by a duly authorised representative. With the nex t feasible
revision, this will result in
- updating of maintenance documentation to show pre and post SB data.
- updating of maintenance and operational documentation to show post SB
data after embodiment.
If this SB requires previous or simultaneous accomplishmen t of other SBs,
EADS-CASA(MTAD) shall automatically include them in the ma nual revisions.
Please return this completed sheet to:
AIRBUS MILITARY
ENGINEERING SUPPORT - SERVICE ENGINEERING
Autovia A-4, km 528,5. San Pablo North.
41020 Seville (Spain)
TEL: (34) 95 459 41 69
FAX: (34) 95 459 35 31
Date:Jul 09/2014 SB-235-26-0005
Original Pag : 1 of 1

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.