# CFM International Service Bulletin LEAP-1A-72-00-0460-01A-930A-D: No revision named

- Rights: © CFM International. Filed by the FAA in regulations.gov docket FAA-2022-0877; AD 2022-15-04 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [CFM International Service Bulletin LEAP-1A-72-00-0460-01A-930A-D](https://openairdocs.org/service-documents/cfm/leap1a-72-00-0460-01a930a-d.md)
- Title as filed: CFM Service Bulletin LEAP-1A-72-0460R0 Dated 4-1-2022
- Pages: 17
- PDF: https://openairdocs.org/files/sha256/6a/b0/6ab08f7c0d645de3c95a1b95f443b80d31f23cac8b6d6906bfbbd4e7794dd7ec
- Page: https://openairdocs.org/service-documents/cfm/leap1a-72-00-0460-01a930a-d/file/6ab08f7c0d64

## Text

Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
HIGH
PRESSURE
TURBINE
ROT
OR
ASSEMBL
Y
(72
-
52
-
00)
-
INSPECTION
OF
HPT
MODULE
T
O
DETERMINE
HPT
ROT
OR
INTERST
AGE
SEAL
AND
HPT
ROT
OR
ST
AGE
2
DISK
REPLACEMENT
SERVICE
BULLETIN
T
able
of
contents
1.
REVISION
INFORMA
TION
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
2.
SUMMAR
Y
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
A.
Reason
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
3.
PLANNING
INFORMA
TION
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
A.
Applicability
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
B.
Concurrent
requirements
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
C.
Reason
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
D.
Description
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
E.
Compliance
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
F
.
Approval
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
G.
Manpower
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
H.
W
eight
and
balance
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
I.
Electrical
load
data
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
J.
Software
accomplishment
summary
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
K.
Referenced
documentation
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
L.
Documentation
af
fected
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
M.
Industry
support
information
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
N.
Interchangeability
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
4.
MA
TERIAL
INFORMA
TION
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
5.
ACCOMPLISHMENT
INSTRUCTIONS
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
A.Engine
Inspection
Instructions
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
B.In
-
Shop
Disassembly
,
Inspection,
and
Removal
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
7
6.
ADDITIONAL
INFORMA
TION
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
17
A.
Additional
information
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
17
List
of
tables
T
able:
References
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
2
T
able
1:
Engine
Inspection
Threshold
for
the
HPT
Rotor
Interstage
Seal
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
T
able
2:
Engine
Inspection
Threshold
for
the
HPT
Rotor
Stage
2
Disk
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
6
T
able
3:
CFM
Contact
Information
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
17
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
1/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 2

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
List
of
figures
Figure
1
(Sheet
1/2):
HPT
Rotor
Assembly
Piece
-
part
Inspection
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
Figure
1
(Sheet
2/2):
HPT
Rotor
Assembly
Piece
-
part
Inspection
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
10
Figure
2:
Engine
Threshold
Removal
Calculation
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1
1
Figure
3
(Sheet
1/2):
Stage
2
HPT
Nozzle
Assembly
Location
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
12
Figure
3
(Sheet
2/2):
Stage
2
HPT
Nozzle
Assembly
Location
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
Figure
4:
Shop
Actions
to
Determine
Serviceability
of
HPT
Hardware
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
14
Figure
5
(Sheet
1/2):
HPT
Stator
Stationary
Seal
Location
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
15
Figure
5
(Sheet
2/2):
HPT
Stator
Stationary
Seal
Location
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
16
CFM
PROPRIET
AR
Y
INFORMA
TION
The
information
contained
in
this
document
is
CFM
proprietary
information
and
is
disclosed
in
confidence.
It
is
the
property
of
CFM
and
shall
not
be
used,
disclosed
to
others
or
reproduced
without
the
express
written
consent
of
CFM,
including,
but
without
limitation,
it
is
not
to
be
used
in
the
creation,
manufacture,
development,
or
derivation
of
any
repairs,
modifications,
spare
parts,
design,
or
configuration
changes
or
to
obtain
F
AA
or
any
other
government
or
reg-
ulatory
approval
to
do
so.
If
consent
is
given
for
reproduction
in
whole
or
in
part,
this
notice
and
the
notice
set
forth
on
each
page
of
this
document
shall
appear
in
any
such
reproduction
in
whole
or
in
part.
The
information
contained
in
this
document
may
also
be
controlled
by
U.S.
export
control
laws.
Unauthorized
export
or
re
-
export
is
prohibited.
References
T
able:
References
T
echnical
Publication
LEAP
-
1A
-
05
-
1
1
-
00
-
01A
-
040A
-
C
LEAP
-
1A
-
72
-
00
-
00
-
01A
-
530A
-
C
LEAP
-
1A
-
72
-
00
-
02
-
51A
-
52AA
-
C
LEAP
-
1A
-
72
-
00
-
53
-
01A
-
663B
-
C
LEAP
-
1A
-
72
-
53
-
00
-
01A
-
530A
-
C
LEAP
-
1A
-
72
-
53
-
00
-
01A
-
710A
-
C
LEAP
-
1A
-
72
-
52
-
00
-
01A
-
530A
-
C
LEAP
-
1A
-
72
-
52
-
00
-
01A
-
710A
-
C
LEAP
-
1A
-
72
-
54
-
00
-
01A
-
530A
-
C
LEAP
-
1A
-
72
-
54
-
00
-
01A
-
710A
-
C
Management
information
Manufacturer
recommendation:
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Recommended
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
2/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 3

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
T
ask
type:
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Inspection
Original
issue
date:
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
2022
-
04
-
05
1.
REVISION
INFORMA
TION
Not
Applicable.
2.
SUMMAR
Y
A.
Reason
T
o
reduce
significant
events.
3.
PLANNING
INFORMA
TION
A.
Applicability
This
Service
Bulletin
is
applicable
to:
•
Engine
type:
LEAP
-
1A
•
Engine
model(s):
LEAP
-
1A23,LEAP
-
1A24,LEAP
-
1A24E1,LEAP
-
1A26,LEAP
-
1A26CJ,LEAP
-
1A26E1,LEAP
-
1A29,LEAP
-
1A29CJ,LEAP
-
1A30,LEAP
-
1A32,LEAP
-
1A33,LEAP
-
1A33B2,LEAP
-
1A35A
This
Service
Bulletin
is
applicable
to
these
LEAP
-
1A
engines:
•
LEAP
-
1A
engines,
serial
numbers
598
-
280,
598
-
283,
598
-
284,
598
-
291,
598
-
300,
598
-
302,
598
-
327,
598
-
572,
598
-
629,
598
-
648,
598
-
659,
598
-
667,
598
-
909,
and
599
-
192.
These
serial
numbers
are
the
best
available
data.
Engine
models
are
defined
as
follows:
Group
1:
LEAP
-
1A30,
LEAP
-
1A32,
LEAP
-
1A33,
LEAP
-
1A33B2,
and
LEAP
-
1A35A.
Group
2:
LEAP
-
1A23,
LEAP
-
1A24,
LEAP
-
1A24E1,
LEAP
-
1A26,
LEAP
-
1A26CJ,
LEAP
-
1A26E1,
LEAP
-
1A29,
and
LEAP
-
1A29CJ.
The
high
pressure
turbine
(HPT)
rotor
interstage
seals
and
HPT
rotor
stage
2
disks
listed
in
T
able
1
and
T
able
2
are
af
fected
by
this
Service
Bulletin.
B.
Concurrent
requirements
None.
C.
Reason
(1)
Objective:
T
o
reduce
significant
events.
(2)
Condition:
A
LEAP
-
1A
in
-
service
engine
has
experienced
higher
than
anticipated
operating
temperatures
on
the
HPT
rotor
,
resulting
in
distress
to
the
HPT
rotor
interstage
seal
and
potential
creep.
(3)
Cause:
More
open
operating
clearances
contributed
to
the
HPT
rotor
interstage
seal
operating
at
elevated
temperatures.
(4)
Improvement
and
inspection:
This
Service
Bulletin
provides
a
list
of
af
fected
population
of
14
LEAP
-
1A
engines
that
have
potential
impact
to
chapter
05
life
of
HPT
rotor
interstage
seal
and
HPT
rotor
stage
2
disk
and
required
inspection
procedures
to
determine
their
serviceability
.
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
3/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 4

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
(5)
Substantiation:
Substantiation
is
by
analysis.
D.
Description
This
Service
Bulletin
provides
a
list
of
af
fected
population
of
14
LEAP
-
1A
engines
that
had
non
-
synchronous
vibrations
in
the
past
and
could
have
an
impact
on
the
HPT
rotor
interstage
seal
and
HPT
rotor
stage
2
disk
low
cycle
fatigue
(LCF)
life
due
to
higher
HPT
rotor
interstage
seal
and
HPT
stator
stationary
seal
operating
clearances.
This
Service
Bulletin
recommends
engine
inspection
prior
to
thresholds
defined
in
T
able
1
and
T
able
2
for
inspecting
the
HPT
module
for
stage
2
HPT
nozzle
assembly
honeycomb
and
HPT
stator
stationary
seal
honeycomb
rub
depths
to
determine
if
replacement
of
the
HPT
rotor
interstage
seal
and
HPT
rotor
stage
2
disk
is
required.
E.
Compliance
Category
2
CFM
recommends
that
you
do
this
Service
Bulletin
at
next
shop
visit
but
before
inspection
thresholds
specified
in
T
able
1
for
the
HPT
rotor
interstage
seal
and
in
T
able
2
for
the
HPT
rotor
stage
2
disk.
Impact
A
This
recommendation
is
to
address
a
condition
that
may
af
fect
Flight
Safety
.
NOTE:
Stage
2
nozzle
honeycomb
seal
and
HPT
stator
stationary
honeycomb
seal
on
each
affected
engine
must
be
inspected
before
the
most
limiting
thresholds
between
T
able
1
for
the
HPT
rotor
interstage
seal
and
T
able
2
for
the
HPT
rotor
stage
2
disk.
NOTE:
This
Service
Bulletin
can
be
done
in
shop.
This
Service
Bulletin
is
of
fered
to
improve
the
reliability
or
performance
of
your
CFM
product,
or
to
help
prevent
the
occurrence
of
the
event
or
condition
described
in
this
Service
Bulletin.
If
the
operator
elects
not
to
participate
in
the
bulletin,
that
decision
will
be
taken
into
consideration
by
CFM
in
evaluating
future
product
performance
issues
that
may
arise
in
the
operator
’
s
fleet.
F
.
Approval
The
technical
content
of
this
Service
Bulletin
is
approved
by
the
F
AA
and
under
the
Authority
of
DOA
No.
EASA.21J.086.
G.
Manpower
After
you
get
access
to
the
HPT
module,
you
will
need
approximately
6
man
-
hours
to
do
the
inspection
portion
of
this
Service
Bulletin.
H.
W
eight
and
balance
W
eight
and
balance
are
not
changed.
I.
Electrical
load
data
Not
Applicable.
J.
Software
accomplishment
summary
Not
Applicable.
K.
Referenced
documentation
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
4/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 5

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
CFM
LEAP
-
1A
Engine
Shop
Manual
(ESM),
CFM
-
TP
-
610
SM.20
L.
Documentation
affected
None.
M.
Industry
support
information
None.
N.
Interchangeability
Not
Applicable.
4.
MA
TERIAL
INFORMA
TION
List
of
material
sets
Not
Applicable.
List
of
support
equipment
Not
Applicable.
List
of
supplies
Not
Applicable.
List
of
spares
Not
Applicable.
List
of
removed
spares
Not
Applicable.
5.
ACCOMPLISHMENT
INSTRUCTIONS
A.
Engine
Inspection
Instructions
(1)
The
inspection
threshold
for
each
ESN
is
listed
in
T
able
1
for
the
HPT
rotor
interstage
seal
(1,
Figure
1
)
(SIN:
157B0)
and
T
able
2
for
the
HPT
rotor
stage
2
disk
(3)
(SIN:
158B0).
The
LEAP
-
1A
engine
must
be
inspected
before
this
threshold.
T
able
1:
Engine
Inspection
Threshold
for
the
HPT
Rotor
Interstage
Seal
ESN
Current
Engine
Rating
HPT
Rotor
Interstage
Seal
S/N
Inspection
Threshold
for
Group
1
(CSN)
Inspection
Threshold
for
Group
2
(CSN)
598
-
280
1A26
WESF2870
4,000
1
1,100
598
-
283
1A26
WESF3374
4,000
1
1,100
598
-
284
1A26
WESF3926
4,000
1
1,100
598
-
291
1A26
WESF3381
2,200
1
1,100
598
-
300
1A26
WESF3563
4,000
1
1,100
to
be
continued
...
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
5/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 6

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
ESN
Current
Engine
Rating
HPT
Rotor
Interstage
Seal
S/N
Inspection
Threshold
for
Group
1
(CSN)
Inspection
Threshold
for
Group
2
(CSN)
598
-
302
1A32
WESF3383
4,000
1
1,100
598
-
327
1A26
WESF3932
4,000
1
1,100
598
-
572
1A26
WESF6688
4,000
1
1,100
598
-
629
1A32
FIA15TGA
1
1,100
1
1,100
598
-
648
1A26
XAE018BJ
700
1
1,100
598
-
659
1A26
WESF7141
4,000
1
1,100
598
-
667
1A26
XAE013BJ
700
1
1,100
598
-
909
1A26
FIA18FMH
3,300
1
1,100
599
-
192
1A26
WESF8994
700
1
1,100
NOTE:
Group
1:
LEAP
-
1A30,
LEAP
-
1A32,
LEAP
-
1A33,
LEAP
-
1A33B2,
and
LEAP
-
1A35A.
Group
2:
LEAP
-
1A23,
LEAP
-
1A24,
LEAP
-
1A24E1,
LEAP
-
1A26,
LEAP
-
1A26CJ,
LEAP
-
1A26
E1,
LEAP
-
1A29,
and
LEAP
-
1A29CJ.
T
able
2:
Engine
Inspection
Threshold
for
the
HPT
Rotor
Stage
2
Disk
ESN
Current
Engine
Rating
HPT
Rotor
Stage
2
Disk
S/N
Inspection
Threshold
for
Group
1
(CSN)
Inspection
Threshold
for
Group
2
(CSN)
598
-
280
1A26
TMT3NC79
8,900
9,900
598
-
283
1A26
TMT3NC84
8,900
9,900
598
-
284
1A26
TMTF0548
8,900
9,900
598
-
291
1A26
TMT3NC82
8,200
9,900
598
-
300
1A26
TMT10M3T
8,900
9,900
598
-
302
1A32
TMT3NC75
8,900
9,900
598
-
327
1A26
TMTF0534
8,900
9,900
598
-
572
1A26
TMT124P0
8,900
9,900
598
-
629
1A32
TMT1
1C51
8,900
9,900
598
-
648
1A26
TMT124NP
6,300
9,900
598
-
659
1A26
TMT12D31
8,900
9,900
598
-
667
1A26
TMT12HK7
6,300
9,900
598
-
909
1A26
TMT14EFH
8,200
9,900
599
-
192
1A26
TMT13RLL
6,300
9,900
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
6/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 7

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
NOTE:
Group
1:
LEAP
-
1A30,
LEAP
-
1A32,
LEAP
-
1A33,
LEAP
-
1A33B2,
and
LEAP
-
1A35A.
Group
2:
LEAP
-
1A23,
LEAP
-
1A24,
LEAP
-
1A24E1,
LEAP
-
1A26,
LEAP
-
1A26CJ,
LEAP
-
1A26
E1,
LEAP
-
1A29,
and
LEAP
-
1A29CJ.
(2)
If
an
engine
re
-
rating
has
not
occurred,
use
the
thresholds
from
T
able
1
and
T
able
2
as
appropriate.
In
case
of
engine
re
-
rating
from
Group
2
to
Group
1
or
vice
-
versa,
use
the
Miner's
rule
to
calculate
the
modified
inspection
threshold
for
the
HPT
rotor
interstage
seal
(1)
(SIN:
157B0)
and
HPT
rotor
stage
2
disk
(3)
(SIN:
158B0).
Threshold
values
from
T
able
1
or
T
able
2
must
be
used
appropriately
to
calculate
new
threshold.
Refer
to
the
LEAP
-
1A
ESM,
05
-
1
1
-
00,
DESCRIPTION
(
Refer
to:
LEAP
-
1A
-
05
-
1
1
-
00
-
01A
-
040A
-
C
)
and
flowchart
1
in
Figure
2
.
B.
In
-
Shop
Disassembly
,
Inspection,
and
Removal
(1)
Remove
the
core
module
assembly
(SIN:
00104)
from
the
engine
assembly
(SIN:
00002).
Refer
to
the
LEAP
-
1A
ESM,
72
-
00
-
00,
DISASSEMBLE
PROCEDURE
(
Refer
to:
LEAP
-
1A
-
72
-
00
-
00
-
01A
-
530A
-
C
).
(2)
Remove
the
HPT
rotor
assembly
(SIN:
15000,
Figure
1
)
from
the
core
module
assembly
(SIN:
00104).
Refer
to
the
LEAP
-
1A
ESM,
72
-
00
-
02,
REMOVE
ENGINE
MODULAR
SECTION
(
Refer
to:
LEAP
-
1A
-
72
-
00
-
02
-
51A
-
52AA
-
C
).
(3)
Do
an
inspection
of
the
honeycomb
of
the
stage
2
HPT
nozzle
assembly
(1,
Figure
3
)
(SIN:
17300)
as
specified
in
below
criteria.
Also,
refer
to
Flowchart
2
in
Figure
4
which
explains
the
disposition
steps
and
do
as
follows:
(a)
T
ake
measurements
at
eight
equally
spaced
locations
circumferentially
,
which
include
approximately
deepest
rub
location.
Refer
to
Figure
3
for
more
information
and
the
criteria
that
follow:
1
Maximum
permitted
individual
groove
depth
0.070
inch
(1.78
mm)
2
Maximum
permitted
average
depth
of
all
grooves
0.049
inch
(1.24
mm)
3
Maximum
permitted
individual
groove
width
is
0.225
inch
(5.72
mm)
4
There
must
be
four
annular
wear
grooves
separated
by
a
minimum
of
1.0
complete
cell.
There
must
be
1.0
complete
cell
on
the
forward
and
aft
ends
of
the
honeycomb.
5
Report
the
results
to
CFM.
Refer
to
paragraph
6.,
ADDITIONAL
INFORMA
TION
for
CFM
contact
in-
formation.
(b)
If
the
stage
2
HPT
nozzle
assembly
(1,
Figure
3
)
(SIN:
17300)
honeycomb
inspection
meets
all
above
criteria,
no
action
is
necessary
on
the
stage
2
HPT
nozzle
assembly
(1)
(SIN:
17300),
HPT
rotor
inter-
stage
seal
(1,
Figure
1
)
(SIN:
157B0),
and
HPT
rotor
stage
2
disk
(3)
(SIN:
158B0).
(c)
If
the
stage
2
HPT
nozzle
assembly
(1,
Figure
3
)
(SIN:
17300)
honeycomb
fails
to
meet
any
of
the
above
criteria,
do
as
follows:
1
Replace
the
stage
2
HPT
nozzle
assembly
(1)
(SIN:
17300)
honeycomb.
Refer
to
the
LEAP
-
1A
ESM,
72
-
00
-
53,
REPLACEMENT
OF
INTERST
AGE
SEAL
(
Refer
to:
LEAP
-
1A
-
72
-
00
-
53
-
01A
-
663B
-
C
)
as
follows:
a
If
the
stage
2
HPT
nozzle
assembly
(1,
Figure
3
)
(SIN:
17300)
honeycomb
replacement
is
not
possible,
replace
the
stage
2
HPT
nozzle
assembly
(1).
Removal
and
installation
instructions
have
not
changed.
Refer
to
the
LEAP
-
1A
ESM,
72
-
53
-
00,
DISASSEMBLE
PROCEDURE
(
Refer
to:
LEAP
-
1A
-
72
-
53
-
00
-
01A
-
530A
-
C
)
and
ASSEMBLE
PROCEDURE
(
Refer
to:
LEAP
-
1A
-
72
-
53
-
00
-
01A
-
710A
-
C
).
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
7/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 8

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
2
If
the
engine
is
a
Group
2
engine,
remove
and
replace
the
HPT
rotor
interstage
seal
(1,
Figure
1
)
(SIN:
157B0).
Removal
and
installation
instructions
have
not
changed.
Refer
to
the
LEAP
-
1A
ESM,
72
-
52
-
00,
DISASSEMBLE
PROCEDURE
(
Refer
to:
LEAP
-
1A
-
72
-
52
-
00
-
01A
-
530A
-
C
)
and
ASSEM-
BLE
PROCEDURE
(
Refer
to:
LEAP
-
1A
-
72
-
52
-
00
-
01A
-
710A
-
C
).
3
If
the
engine
is
a
Group
1
engine
or
has
operated
in
the
two,
Group
1
and
Group
2
engine
models,
remove
and
replace
the
HPT
rotor
interstage
seal
(1,
Figure
1
)
(SIN:
157B0)
and
HPT
rotor
stage
2
disk
(3)
(SIN:
158B0).
Removal
and
installation
instructions
have
not
changed.
Refer
to
the
LEAP
-
1A
ESM,
72
-
52
-
00,
DISASSEMBLE
PROCEDURE
(
Refer
to:
LEAP
-
1A
-
72
-
52
-
00
-
01A
-
530A
-
C
)
and
AS-
SEMBLE
PROCEDURE
(
Refer
to:
LEAP
-
1A
-
72
-
52
-
00
-
01A
-
710A
-
C
).
(4)
Do
an
inspection
of
the
honeycomb
of
the
HPT
stator
stationary
seal
(1,
Figure
5
)
(SIN:
925A3)
as
specified
in
below
criteria
and
do
as
follows:
(a)
T
ake
measurements
of
four
equally
spaced
locations
circumferentially
,
which
include
approximately
deep-
est
rub
location.
Refer
to
Figure
5
for
more
information
and
the
criteria
that
follow:
1
Maximum
permitted
average
depth
of
all
grooves
0.012
inch
(0.30
mm)
2
Maximum
permitted
individual
groove
width
is
0.170
inch
(4.32
mm)
3
There
must
be
four
annular
wear
grooves
separated
by
a
minimum
of
1.0
complete
cell.
There
must
be
1.5
complete
cells
on
the
forward
and
aft
ends
of
the
honeycomb.
4
Report
the
results
to
CFM.
Refer
to
paragraph
6.,
ADDITIONAL
INFORMA
TION
for
CFM
contact
in-
formation.
(b)
If
the
HPT
stator
stationary
seal
(1,
Figure
5
)
(SIN:
925A3)
honeycomb
inspection
meets
all
of
the
above
criteria,
no
action
is
necessary
for
the
HPT
stator
stationary
seal
(1)
(SIN:
925A3).
(c)
If
the
HPT
stator
stationary
seal
(1)
(SIN:
925A3)
honeycomb
inspection
does
not
meet
all
of
the
above
criteria,
do
as
follows:
1
Remove
and
replace
the
HPT
stator
stationary
seal
(1)
(SIN:
925A3).
Removal
and
installation
in-
structions
have
not
changed.
Refer
to
the
LEAP
-
1A
ESM,
72
-
54
-
00,
DISASSEMBLE
PROCEDURE
(
Refer
to:
LEAP
-
1A
-
72
-
54
-
00
-
01A
-
530A
-
C
)
and
ASSEMBLE
PROCEDURE
(
Refer
to:
LEAP
-
1A
-
72
-
54
-
00
-
01A
-
710A
-
C
).
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
8/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 9

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
HPT
Rotor
Assembly
Piece
-
part
Inspection
Figure
1
(Sheet
1
of
2)
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
9/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 10

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
HPT
Rotor
Assembly
Piece
-
part
Inspection
Figure
1
(Sheet
2
of
2)
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
10/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 11

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Engine
Threshold
Removal
Calculation
Figure
2
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
1
1/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 12

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Stage
2
HPT
Nozzle
Assembly
Location
Figure
3
(Sheet
1
of
2)
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
12/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 13

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Stage
2
HPT
Nozzle
Assembly
Location
Figure
3
(Sheet
2
of
2)
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
13/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 14

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Shop
Actions
to
Determine
Serviceability
of
HPT
Hardware
Figure
4
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
14/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 15

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
HPT
Stator
Stationary
Seal
Location
Figure
5
(Sheet
1
of
2)
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
15/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 16

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
HPT
Stator
Stationary
Seal
Location
Figure
5
(Sheet
2
of
2)
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
Page
16/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

### Page 17

LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
6.
ADDITIONAL
INFORMA
TION
A.
Additional
information
T
able
3:
CFM
Contact
Information
CFM
SA
ZONE
CFM
Inc.
Zone
Customer
Support
Center:
http://mycfmportal.com
Widget
AskCFM
GE
A
viation
Fleet
Support:
http://www
.geaviation.com/support
OR
OR
E
-
mail:
cfm.csc@safrangroup.com
E
-
mail
(USA):
aviation.fleetsupport@ge.com
E
-
mail
(China
and
Asia):
aviation.fleetsupport.cn@ge.com
OR
OR
PSE
CFM
SAFRAN
Aircraft
Engines
Site
de
MELUN
MONTEREAU
BP
1936
-
77019
Melun
Cedex
FRANCE
GE
A
viation
M/D
Rm.
285
One
Neumann
W
ay
OH
45215
USA
OR
OR
Phone:
+33
1
64
14
88
66
Fax:
+33
1
64
14
87
65
USA
Phone:
877
-
432
-
3272
International
Phone:
(513)
552
-
3272
China
and
Asia
Phone:
+
86
21
38777666
LEAP
-
1A
-
72
-
00
-
0460
-
01A
-
930A
-
D
End
of
data
module
Page
17/
17
Issue
001
-
00
-
2022
-
04
-
01
©
CFM
PROPRIET
AR
Y
INFORMA
TION:
Subject
to
the
restrictions
on
the
media.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.