CIRRUS  SR22T
Service Bulletin
SB 2X-71-17 R1
Page 1
EFFECTIVITY:
SB 2X-71-17 R1Number:
1. COMPLIANCE
Mandatory: Cirrus Design considers this Service Bulletin to be MANDATORY . Accomplish this Service 
Bulletin within the next 10 Flight Hours. Compliance time begins upon receipt of this Service Bulletin. 
2. EFFECTIVITY
Group A: SR22T Serials 0001-0169, except 0154, 0159, 0163.
and
Group B: SR22T Serials 0004, 0019, 0027, 0047, 0097, 0126, 0127, 0135, 0138, 0139, 0144, 0155, 0157, 
0158, 0160, 0161.
Aircraft in Group B had the Reinforced Silicone Fiberglass Seals installed at the factory, however, the air 
box flange welds and slots were incorrectly modified. Inspect and modify the air box flange welds and slots 
in accordance with this Service Bulletin.
This Service Bulletin has been revised to expand effectivity.
Operators who have successfully complied with the original release of this Service Bulletin, dated July 21, 
2011, need take no further action.
3. APPROVAL
FAA approval has been obtained on all technical data in this Service Bulletin that affects type design.
4. PURPOSE
A condition can occur in which the induction system air box seal(s) could become disbonded and ingested 
into the turbocharger compressor.
5. DESCRIPTION
This Service Bulletin provides instructions for the replacement of the air box seals.
6. WARRANTY INFORMATION
For aircraft under warranty at the issue date of this Service Bulletin, Cirrus Design will cover all parts and 
labor costs for this Service Bulletin if the work is accomplished within the Compliance time period and the 
work is performed at an authorized Cirrus Design Service Center.
7. MANPOWER REQUIREMENTS
2.25 manhours.
8. OTHER PUBLICATIONS AFFECTED
SR22/22T Airplane Maintenance Manual (p/n 13773-001)
SR22/22T Illustrated Parts Catalog (p/n 13744-001)
9. WEIGHT AND BALANCE
N/A
SNS SUBJECT: 71-60 AIR INTAKES - Disbonding Of Induction System Air Box Seal(s)
July 21, 2011Issued:
Sept 30, 2011Revised:

### Page 2

CIRRUS  SERVICE BULLETIN MODEL SR22T
SB 2X-71-17 R1
Page 2
EFFECTIVITY:
 Sept 30, 2011
10. MATERIAL INFORMATION
The following parts are required to comply with this Service Bulletin. Parts can be obtained from an Autho-
rized Cirrus Design Service Center or Parts Distributor.
Order kit 70257-001 to obtain the following parts. 
11. ACCOMPLISHMENT INSTRUCTIONS
A. Acquire necessary tools, equipment, and supplies.
B. Remove engine cowling. (Refer to AMM 71-10)
C. Remove clamp securing air box to turbocharger.
D. Disconnect air box from turbocharger.
E. Remove and discard black rubber seal from air box.
F . Remove residual adhesive from air box.
G. Using Grinding Wheel, grind weld on outside diamet er of airbox fitting flush to surrounding surface. 
(See Figure 1)
CAUTION: Do not extend slots into any weld.
H. Affected Serials in Range 0001 thru 0151, LH Air Box Only;
Using Cut-Off Tool, extend three of the four air box flange slots to 0.90 inch (2.29 cm) with full 
radius on the end. Do not extend the top slot nearest to the weld.
I. Affected Serials in Range 0001 thru 0151, LH Air Box Only;
Using Cut-Off Tool, increase width of all four air box flange slots to 0.13 inch (3.30 mm).
J. Affected Serials in Range 0152 thru 0169, LH Air Box Only;
Using Cut-Off Tool, extend all four air box flange slots to 0.90 inch (2.29 cm) with full radius on 
the end.
K. All Affected Serials, RH Air Box Only;
Using Cut-Off Tool, increase width of all four air box flange slots to 0.13 inch (3.30 mm).
Item No. Description P/N or Spec. Supplier Quantity
1 Reinforced Silicone Fiberglass  Seal 29486-001 Cirrus Design 2
Description P/N or Spec. Supplier Purpose
Grinding Wheel NA Any Source Abrading
Cut-Off Tool NA Any Source Cutting
Alodine Pen N/A Any Source Corrosion Prevention
Emery Cloth 120 Grit Any Source Abrading
Isopropyl Alcohol NA Any Source Solvent Cleaning
RTV Prime Coat PR1204 Dow Corning Adhesive Primer
RTV Sealant 736 Dow Corning Adhesive

### Page 3

CIRRUS  SERVICE BULLETIN MODEL SR22T
SB 2X-71-17 R1
Page 3
EFFECTIVITY:
 Sept 30, 2011
L. All Affected Serials, RH Air Box Only:
Using Cut-Off Tool, extend three of the four air box flange slots to 0.90 inch (2.29 cm) with full 
radius on the end. Do not extend the top slot nearest to the weld.
M. Touch-up reworked areas with alodine pen.
N. Abrade inside of Reinforced Silicone Fiberglass Seal with emery cloth and solvent clean with isopropyl 
alcohol.
O. Abrade induction mounting flange on turbocharger with emery cloth and solvent clean with isopropyl 
alcohol. 
P . Clean air box of any residual machining debris.
Q. Apply PR1204 RTV prime coat to turbocharger induction mounting flange. Cure for 2 hours.
R. Apply a thin coating of 736 RTV sealant turbocharger induction mounting flange.
S. Install Reinforced Silicone Fiberglas s Seal to mounting flange pushing seal as far aft as possible. 
Remove excess RTV. Cure for 24 hours.
CAUTION: Upon installation, If airbox fit is loose, remove from turbocharger, and use clamp to 
slightly reduce flange diameter. Use care not to over-compress and cause fit-up prob-
lems.
T. Install air box over turbocharger induction mounting flange. Torque clamp to 90-100 in-lb (10-11 Nm).
U. Ensure FOD cannot enter induction system by inspecting air box flange and verifying fiberglass seal 
completely blocks air box slots. (See Figure 1)
V. Install clamp securing air box to turbocharger.
W. Repeat procedure on opposite turbocharger.
X. Install engine cowling. (Refer to AMM 71-10)
Y . Complete airplane records by noting compliance with SB 2X-71-17R1 in Aircraft Logbook.

### Page 4

CIRRUS  SERVICE BULLETIN MODEL SR22T
SB 2X-71-17 R1
Page 4
EFFECTIVITY:
 Sept 30, 2011
Figure 1
Air Box Seal Installation
0.90 inch
(2.29 cm)
DO NOT LENGTHEN
 UPPER LOCATION
0.90 inch
(2.29 cm)
0.13 inch
(3.30 mm)
LH side: Serials 22T-0001 thru 22T-0151.
RH side: Serials 22T-0001 thru 22T-0169.
LH side: Serials 22T-0152 thru 22T-0169.
SLOT MODIFICATION
AIR BOX
(REF)
CLAMP
(REF)
SEAL
(REF)
SR2_SB71_1427
TURBOCHARGER
(REF)
Grind indicated weld on outside diameter of
airbox fitting flush.
Ensure FOD cannot enter induction system by
inspecting air box flange and verifying fiberglass
seal completely blocks air box slots.
NOTE
3 PLC'S
4 PLC'S
4 PLC'S

### Page 5

CIRRUS  SR22T
Service Bulletin
Use this form to submit a Publications Change Request to our Engineering Department and/or to tell us what 
you think of the quality of this publication. We will use the data you provide us to improve the quality of our tech-
nical publications.
SB 2X-71-17 R1Number: Service Loop Evaluation Form
Contact Information:
Organization: _________________________________ Today’s Date: __________________________
Address: ____________________________________ Telephone No.: _________________________
City/ST/Zip: __________________________________ Fax No: _______________________________
Prepared By: _________________________________ E-Mail: _______________________________
Title:________________________________________
Location of Publication Change Request:
Chapter Number: Section Number: Figure No (IPC or WM only): ___________________
Page Number: Page Date: Illustration Number (if applicable): _______________
Please consider the following suggestions for change:
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -  -
Evaluation:
Please rate the quality of this publication. (good) 4 3 2 1 (poor)
Please rate the quality of the illustrations. (good) 4 3 2 1 (poor)
Is this publication easy to understand? (good) 4 3 2 1 (poor)
Is this publication easy to use? (good) 4 3 2 1 (poor)
Are the Material and Accomplishment Instructions accurate? (good) 4 3 2 1 (poor)
Is the Manpower estimate accurate? (good) 4 3 2 1 (poor)
Give the completed evaluation form to your Cirrus Field Service Representative 
or send this form to Cirrus Design Corporation:
Manager - Technical Publications
4515 Taylor Circle
Duluth, MN 55811
SNS SUBJECT: 71-60 AIR INTAKES - Disbonding Of Induction System Air Box Seal(s)
Sept 30, 2011Issued:

### Page 6

Cirrus Design Corp
4515 Taylor Circle
Duluth, MN
55811-1548
STAMP
CIRRUS DESIGN CORPORATION
4515 TAYLOR CIRCLE
DULUTH, MN
55811-1548

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.