### Page 1

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 1 of 18 
20-Dec-2017 
 
WORK INSTRUCTION 
 WI-OSB 42-131 
I GENERAL INFORMATION 
I.1 Subject 
Re-installation of exhaust pipes with directly attached heat shield as a replacement for 
exhaust pipes without directly attached heat shield. 
Re-qualification of this exhaust pipes with directly attached heat shield previously removed. 
Repair of heat shield and heat shield attachment to base pipe. 
I.2 Reference Documents 
DA 42 Series Airplane Maintenance Manual, Doc. No. 7.02.01, latest effective issue. 
Design Change Notice: OÄM 42-315 “Alternative Exhaust Clamp Sheet” 
I.3 Remarks 
a) All work must be done by a certified aircraft service station or a certified aircraft 
maintenance mechanic. 
b) All work, in particular if not described in this work instruction, must be done in accordance 
with the referenced maintenance manual. 
c) For conversion factors between SI units and US/Imperial units refer to AMM Chapter 02. 
d) In case of doubt, contact Diamond Aircraft Industries GmbH. 
II DRAWINGS, SPECIAL TOOLS & MATERIALS 
II.1 Drawings 
A01-VR00735-00-0201 
II.2 Special Tools 
No required special tools.

### Page 2

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 2 of 18 
20-Dec-2017 
 
II.3 Material 
A. Material for Re-Installation of Exhaust Pipe with Directly Attached Heat Shield  
 
Note: Material is for installation on one engine only. 
 
Quantity Part Number Description 
1 
DAI P/N D60-9078-06-
01 / Technify P/Ns 52-
7810-H0001 02, 52-
7810-H0001 03 or 52-
7810-H0001 04 
Exhaust Pipe 
1 D60-7806-00-01 Exhaust Clamp 1 (pos. 4) 
1 D60-7806-00-02 Exhaust Clamp 2 (pos. 5) 
1 D60-7806-00-03 Exhaust Sheet (pos. 6) 
2 DIN 912-M5x20-A2 Hexagon Socket Head Screw (pos. 7) 
2 LN 9338-M5 K-Nut M5 (pos. 9) 
4 DIN 125-A5.3-A2 Washer A2 (pos. 11) 
1 LN 9037-06016 Hexagon Screw (pos. 8) 
1 LN 9338-M6 K-Nut M6 (pos. 10) 
4 BN 806-12x6,2x0,6 Spring Washer (pos. 12) 
1 DIN 9021-B10.5-ZP Washer (pos.13) 
Material is available from Diamond Aircraft Industries.

### Page 3

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 3 of 18 
20-Dec-2017 
 
 
B. Material for Re-Qualification of Exhaust Pipes 
Material for Air-Pressure Test: 
 
Quantity Part Number Description 
1 VR00735-00-02 01*) Adaptor incl. pressure connection and o-ring 
1 VR00735-00-01 01**) Pressure Pad 
3 NM-0000-02355 01**) Hexagon Screws M8x40 
3 NM-0000-01294 01**) Hexagon Nuts M8  
6 NM-0000-00040 01**) Washers M8 
Material including drawing is available from Technify Motors GmbH. 
*) Adaptor may also be produced locally by a maintenance shop in accordance with the attached 
drawing A01-VR00735-00-0201 and standard grade fittings and o-rings 
**) Standard DIN Hardware available may be used for the test. 
 
Material for Hot-Water Test ***): 
 
Quantity Part Number Description 
1 D60-9078-06-01ST01 Cap 
1 D60-9078-06-01ST02 Rubber 
3 DIN 933-M8x30-A2 Bolt 
3 DIN 934-M8-A2 Nut  
3 DIN 125-M8 Washer 
Material is available from Diamond Aircraft Industries. 
***) Cap an Rubber may also be produced locally by a maintenance shop. Standard DIN 
Hardware available may be used for the test. 
 For the Cap use 3 mm thick stainless steel sheet metal. 
 For the Rubber use 2 mm thick rubber mat of EPDM, FKM, Viton or equivalent. 
 Dimensions:

### Page 4

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 4 of 18 
20-Dec-2017 
 
III INSTRUCTIONS 
III.1 Re-Installation of Exhaust Pipes with Directly Attached Heat Shield 
1  Remove engine cowlings in accordance with (i.a.w.) AMM section 71-10. 
2  Remove Exhaust Pipe DAI P/N D60 -9078-06-01_01 / Te chnify P/N 52 -7810-H0014 01, previously installed under OSB 42-122, i.a.w. AMM Section 78-00. 
3  
Make sure that the intermediate flange of the engine is installed correctly to the forward 
engine shock mount. Align a ruler with the straight part of the bottom side of the 
intermediate flange as shown in the picture below. The distance between screw (pos. 3) 
and the ruler must be 13mm. 
  
 
4  
Install Exhaust Pipe with directly attached heat shield DAI P/N D60-9078-06-01 / Technify 
P/Ns 52-7810-H0001 02, 52-7810-H0001 03 or 52-7810-H0001 04 i.a.w. AMM Section 78-
00. 
5  Remove the screw (pos. 3) from the front shock engine mount. 
pos. 3 
intermediate flange

### Page 5

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 5 of 18 
20-Dec-2017 
 
6  
Install the exhaust clamp i.a.w. the pictures without tightening the bolts. 
     
 
13 
7 
 11 
 9 
 
8,12 
 6 
12 
 10 
4 
5 
 3

### Page 6

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 6 of 18 
20-Dec-2017 
 
7  
Make sure that exhaust clamp 1 (pos.4) and exhaust sheet (pos. 6) are arranged as 
shown in the following pictures: 
 
Note: The correct order of arrangement is: 
 hexagon screw (pos. 8) – spring washer (pos. 12) – exhaust sheet (pos. 6) 
– 2 x spring washer (pos. 12 ) – exhaust clamp (pos 4) – spring washer   
(pos 12) – K-nut M6 (pos 10) 
 
8  Tighten Hexagon Screw (pos. 8) until the spring washer pre -tension is 1.5 mm between  the metal sheets. 
9  Tighten Hexagon Socket Head Screws (pos. 7) equally on both sides with 5 NM (3.7 lbf.ft.). 
correct installation 
pos. 4 
pos. 6

### Page 7

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 7 of 18 
20-Dec-2017 
 
10  
Check if the Hexagon Screw (pos. 3) can be installed without applying side force to the 
exhaust pipe. 
If the Hexagom  Screw (pos. 3) cannot be installed without applying side force to the 
exhaust pipe: 
- Loosen the exhaust assembly at the manifold an re-align the exhaust pipe with the 
lower cowling installed in order to keep the pipe centered in the lower cowling        
cut-out and with adequate clearance to surrounding components. Re -install the 
exhaust assembly i.a.w. AMM, section 78-00. 
- If necessary loosen Hexagon Socket Head Screws (pos. 7), re -align exhaust pipe 
clamp and tighten Hexagon Socket Head Screws (pos. 7) i.a.w. item 6. 
11  
Check if the Hexagon Screw (pos. 3) can be installed without applying side force to the 
exhaust pipe. 
If the Hexagon Screw (pos. 3) cannot be installed without applying side force to the exhaust 
pipe: 
- Modify the exhaust pipe bracket by re-working the hole for Hexagon Screw     
(pos. 3) as shown in the picture below so that the Hexagon Screw (pos. 3) can 
be installed without applying a side force to the exhaust pipe. Do not remove 
more material than is needed for tension free installation. 
  
                
smoothen the edges

### Page 8

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 8 of 18 
20-Dec-2017 
 
12  
In case it is not possible to install the exhaust clamp without adequate clearance between 
exhaust pipe and cowling / surrounding components and without applying tension to the 
exhaust pipe, install an alternative exhaust sheet i.a.w. DAI OÄM 42-315. 
Note: The alternative exhaust sheet and corresponding installation instruction 
(OÄM 42 -315) may be obtained through Diamond Aircraft Industries 
Austria (support@diamond-air.at). 
13  
After verification that the Hexagon Screw (pos. 3) can be installed without applying tension 
to the exhaust pipe and that there is adequate clearance between exhaust pipe and lower 
cowling cut -out / surrounding components, secure Hexagon Screw (pos. 3) wit h            
Loctite 272 and torque i.a.w. Technify Motors Repair Manual RM-02-02, Section 71-20.01. 
14  
Examine heat shielding in the engine compartment. Ensure: 
- Installation is compliant with installation requirements in WI-OSB-42-122, Revision 
3 or later 
- No damage or wear to heat shielding 
 
Note: Heat Shield Installation Requirements: 
- Heat shield at the front shock mount: 
 
- Heat protection patch to upper cowling: 
 
 
 
 
 
heat shield

### Page 9

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 9 of 18 
20-Dec-2017 
 
 
- Heat protection patch to the air inlet duct of the lower cowling 
 
- Small heat protection patch to lower cowling: 
 
 
 
 
 
 
 
 
 
 
 
 
 
5 mm 
5 mm 
5 mm

### Page 10

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 10 of 18 
20-Dec-2017 
 
- All patches view: 
 
 
- Edge sealing of heat protection patches: 
 
cowling composite material 
heat protection patch 
Dow Corning 732

### Page 11

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 11 of 18 
20-Dec-2017 
 
 
 
- Heat protection shield to the coolant tube: 
 
 
Note: For detailed installation Procedures refer to in WI-OSB-42-122, Revision 3 or later. 
 
15  Clean working areas, check for foreign objects. 
16  Install engine cowlings i.a.w. AMM section 71-10. - Make sure sufficient clearance of the exhaust pipe is provided. 
17  Do an engine test i.a.w. AMM section 71-00. 
18  
Do a post engine test inspection: 
- Remove engine cowlings in accordance with (i.a.w.) AMM section 71-10. 
- Examine exhaust pipe and cowlings. Ensure no signs of contact and verify 
sufficient positive clearance of exhaust pipe. 
In case of contact, re-align exhaust pipe routing. 
- Install engine cowlings i.a.w. AMM section 71-10. 
19  Make all necessary entries in the airplane logs. 
 
  
cowling composite material 
heat protection patch 
Dow Corning 732

### Page 12

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 12 of 18 
20-Dec-2017 
 
III.2 Re-Qualification of Exhaust Pipes DAI P/N D60-9078-06-01 / Technify P/Ns 52-
7810-H0001 02, 52-7810-H0001 03 or 52-7810-H0001 04 
Note: Either Procedure 1 or 2 may be used for re-qualification of an exhaust pipe. 
Note: Re-qualified exhaust pipes are considered having a TSN of 1500 FH. 
 
Procedure 1: Air-Pressure Test 
 
1  
Examine Exhaust Pipe visually. 
- Clean exhaust pipe. 
- Ensure no visible cracks on inner pipe where visually accessible. 
- Ensure no visible cracks on heat shield. 
- Ensure heat shield is firmly attached to the inner pipe. 
 
Note: On Exhaust pipes Technify P/Ns 52-7810-H0001 03 or 52-7810-H0001 04 the heat 
shield is welded to the exhaust pipe at the marked points. If a single welding point is 
cracked the heat shield is considered to be loose. 
 
This defects may be weld-repaired. Refer to Section III.3. 
2  
Mount the adapter (VR00735 -00-02 01 incl. pressure connection and o -ring) with the  
exhaust pipe, therefore use 3x M8x40 hexagon screws (NM -0000-02355 01), 3x M8  
hexagon nuts (NM-0000-01294 01) and 6x washers (NM-0000-00040 01).

### Page 13

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 13 of 18 
20-Dec-2017 
 
3  
Position the pressure pad (VR00735 -00-01 01) in the internal exhaust pipe and  connect 
the hand compressed air pump to the adapter and fill pressure pad with app. 1 bar. 
 
 
 
 
4  
Apply 0.5 to 0.7 bar to the exhaust system with a compressed air pump. 
 
 
5  If no immediate pressure loss is detected the test is passed and the exhaust pipe is serviceable.

### Page 14

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 14 of 18 
20-Dec-2017 
 
 
Procedure 2: Hot Water Test 
 
CAUTION: When handling with hot water, use adequate safety equipment and precautions to 
protect yourself and co-workers from any harm when getting in contact with hot water or heated 
materials. 
 
1  
Examine Exhaust Pipe visually. 
- Clean exhaust pipe. 
- Ensure no visible cracks on inner pipe where visually accessible. 
- Ensure no visible cracks on heat shield. 
- Ensure heat shield is firmly attached to the inner pipe. 
 
Note: On Exhaust pipes Technify P/Ns 52-7810-H0001 03 or 52-7810-H0001 04 the heat 
shield is welded to the exhaust pipe at the marked points. If a single welding point is 
cracked the heat shield is considered to be loose. 
 
This defects may be weld-repaired. Refer to Section III.3. 
2  
Install the cap with rubber on the exhaust flange and support installation in a vice i.a.w. 
picture below. 
 
Cap,  Rubber Washer,  Nut,  Bolt

### Page 15

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 15 of 18 
20-Dec-2017 
 
3  
Use a funnel to fill the center pipe of the exhaust with exactly 1 liter of hot water (approx. 
70°C). Be very careful to not spill any water. In case of spillage, remove water thoroughly 
and immediately.  
 
 
center pipe

### Page 16

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 16 of 18 
20-Dec-2017 
 
4  
Leave the water in the exhaust for a period of ten minutes. Then check for leakages. 
- Check for signs of water in the area of the manifold. 
 
- Discard water and remove the cap and rubber. Use caution, the water may still be 
hot. 
- Let the exhaust dry. Compressed air may be used to accelerate drying. 
5  If there are no visible leaks or water coming out underneath the heat shield were 
detected, the exhaust is serviceable.

### Page 17

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 17 of 18 
20-Dec-2017 
 
 
III.3 Repair of Heat Shields of DAI P/N D60-9078-06-01 / Technify P/Ns 52-7810-
H0001 03 and 52-7810-H0001 04 
 
Note: If the heat shield is loose a one time repair as follows is permitted. 
 
1  Prepare exhaust pipe for welding: 
- Drill the cracked welding point of the heat shield with a diameter of approximately 6 
mm. Do not thrill thru the inner exhaust pipe. Ref. picture below. 
 
 
 
If the welding point at the elbow is cracked do also drill this welding point and centre the 
heat shield as shown in the picture below.

### Page 18

Diamond Aircraft Industries GmbH 
N. A. Otto-Straße 5 
2700 Wiener Neustadt, Austria 
WI-OSB 42-131 
Revision 0 
Page 18 of 18 
20-Dec-2017 
 
2  Welding: 
- Weld the heat shield at the drill holes to fix the heat shield to the exhaust pipe using 
MAG welding/gas metal arc welding (reference number 135 according to DIN EN 
ISO 4063). Use 1.4316/AISI 308L filler material. 
 
 
 
Note: The staff must be qualified according to ISO 24394, AWS D17.1, HB5299.1 or an 
equivalent national aircraft/aerospace welding approval accepted by the responsible 
authority. 
Note: No re-welding of the manifold joint is allowed.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.