# Embraer Temporary Revision 40.2: No revision named

- Rights: © Embraer S.A. Filed by the FAA in regulations.gov docket FAA-2016-9049; AD 2017-04-12 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Embraer Temporary Revision 40.2](https://openairdocs.org/service-documents/embraer/tr-40-2.md)
- Title as filed: AOM-145-1114-01
- Pages: 62
- PDF: https://openairdocs.org/files/sha256/54/b1/54b158809b362c5f79a5a4972f22169f64eb0441bcd1b94ec5750a1d7917f878
- Page: https://openairdocs.org/service-documents/embraer/tr-40-2/file/54b158809b36

## Text

Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

TRANSMITTAL LETTER  
 
Publication: AOM-145/1114-01 Airplane Operations Manual. 
 
Dear Madam or Sir, 
 
You are receiving the temporary revision 40.2 of AOM, which: 
• Includes reference to the accomplishment of the Service 
Bulletin 145-21-0050; 
• Includes the new block 1-12-60 code 01*, containing 
information about Ground Resets procedures; 
• Includes airplane configuration with Rain Repellent Coating 
installation that can perform the Windshield Wiper functions; 
• Includes information about EGPWS prior version -213-213, 
which does not account man-made obstacles; 
• Includes information indicating that advancing thrust lever until 
86% N2 represents normal system condition. 
*This new block-code is not reflected in the List of Effective pages and 
must be included in your manual following the numbered sequence. 
Temporary Revisions pages are printed in yellow paper. Revised 
pages should be included in your manual facing the current pages. 
They will be incorporated in the next AOM scheduled revision. 
The temporary revision will not be in cluded in the List of Effective 
Pages. 
 
In case of any question, please contact: 
Embraer Flight Operations Support by 
E-mail: opereng@embraer.com.br or phone: (+55 12) 3927 1706 
THIS PAGE IS NOT PART OF THE MANUAL AND MUST NOT BE 
INCORPORATED IN YOUR AOM. PLEASE DISCARD IT AFTER 
READING.

### Page 2

(No text on this page.)

### Page 3

In connection with the use of this document, Embraer does not provide any express or implied warranties  
and expressly disclaims any warranty of merchantability or fitness for a particular purpose. 
Copyright © 2014 by Embraer S.A. All rights reserved. 
 
 
AIRPLANE OPERATIONS MANUAL 
VOLUME 1 
 
EMBRAER S.A. 
 
This manual is applicable to the EMB-145 airplanes all models 
equipped with AE3007A, AE3007A1/1, AE3007A1, AE3007A1P 
and AE3007A1E engines, ERJ-140 airplanes all models 
equipped with AE3007A1/3 engines and to the EMB-135 
airplanes all models equipped with AE3007A3 and AE3007A1/3 
engines and operating under ANAC, FAA and JAA/EASA 
certifications. 
 
THIS PUBLICATION IS INCOMPLETE  WITHOUT AIRPLANE 
OPERATIONS MANUAL AOM–145/1114 VOLUME 2 
 
AOM–145/1114-01 
OCTOBER 31, 1996 
TEMPORARY REVISION 40.2 – APRIL 04, 2014

### Page 4

(No text on this page.)

### Page 5

AIRPLANE 
OPERATIONS 
MANUAL 
RECORD OF 
TEMPORARY 
REVISIONS 
 
TEMPORARY REVISION 40.2  RTR-1
 
 
 
RECORD OF TEMPORARY REVISIONS 
AOM–145/1114-01 
 
TR 40.1 ............................................................................ DEC 19, 2013 
TR 40.2 ............................................................................ APR 04, 2014

### Page 6

RECORD OF 
TEMPORARY 
REVISIONS 
AIRPLANE 
OPERATIONS 
MANUAL 
 
 
RTR-2  TEMPORARY REVISION 40.2
 
 
INTENTIONALLY BLANK

### Page 7

(No text on this page.)

### Page 8

LIMITATIONS 
FAA 
AIRPLANE 
OPERATIONS 
MANUAL 
 
 
1-01-12 
Page 
1 
Code 
05  TEMPORARY REVISION 40.2
 
AOM-145/1114  
SUPPLEMENTARY OPERATIONAL 
LIMITATIONS 
OPERATIONAL ENVELOPE 
APPLICABLE ONLY TO EMB-145XR AND LR MODELS POST-MOD. 
SB 145-21-0050 OR EQUIPPED WITH AN EQUIVALENT 
MODIFICATION FACTORY INCORPORATED 
-5000
0
5000
10000
15000
20000
25000
30000
35000
40000
-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60
ALTITUDE - ft 
    c
STATIC AIR TEMPERATURE - °C
ISA + 35°C
145XRFAA100 - 30JUN2003
TAKEOFF, LANDING                    c
37000 ft
-21.5°C
-1000 ft
52°-54°C
10000 ft
-65°C
-40°C
 
NOTE: - In the event of a landing below -40°C, the airplane may not 
takeoff without further hard landing maintenance inspection 
(Refer to AMM Task 5-50-02). 
- Minimum Total Air Temperature in cruise flight above 
25000 ft is -45°C. 
- Only APU T-62T-40C14 is allowed for operations on 
ground above 8000 ft.

### Page 9

(No text on this page.)

### Page 10

LIMITATIONS AIRPLANE 
OPERATIONS 
MANUAL  
 
1-01-30 
Page 
1 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
ENHANCED GROUND PROXIMITY WARNING 
SYSTEM (EGPWS) 
The following limitations are applicable to the Enhanced Ground 
Proximity Warning System (EGPWS): 
− The Allied-Signal Enhanced Ground Proximity Warning System 
Pilot’s Guide, Document Number 060-4241-000, March 1997 
edition (or later revision of the manual) or ANAC accepted 
Operating Manual, must be available to the flight crew. 
− Allied-Signal Application Software version 202 and Configuration 
Software version 202 or later must be installed. 
− Navigation is not to be predicated on the use of the Terrain 
Awareness Display. 
− The Terrain Display is intended to be used as a situational tool only 
and may not provide the accuracy and/or fidelity on which to solely 
base terrain avoidance maneuvering. 
− The EGPWS displays and alerting algorithms prior version              
-213-213 currently do not account for man-made obstacles. 
− The EGPWS must be inhibited in the following conditions: 
NOTE: To inhibit the Terrain Awareness Alerting and Display 
function, press the TERRAIN SYS OVRD button. 
− Within 15 NM of takeoff, approach or landing at airports that 
have no approved instrument approach procedure or not 
included in the EGPWS Allied Signal database (encompasses 
airports which runways are shorter than 1070 m); 
− When GPS is failed; 
− When FMS is operating in Dead Reckoning Mode. 
NOTE: This will not affect the basi c GPWS functi ons (modes 1 
to 7). If the FMS is restored after a period of inadequacy, 
the EGPWS may be enabled by pressing again the 
TERRAIN SYS OVRD button. 
− During QFE operations for airplanes featuring EGPWS software 
versions prior to the -216 version; 
NOTE: QFE operation is allowed with FMS Honeywell or FMS 
Universal Post-Mod. SB145- 34-0112 when featuring 
EGPWS software versions -216 and on.

### Page 11

(No text on this page.)

### Page 12

LIMITATIONS AIRPLANE 
OPERATIONS 
MANUAL  
 
1-01-30 
Page 
1 
Code 
03  TEMPORARY REVISION 40.2
 
AOM-145/1114 
ENHANCED GROUND PROXIMITY WARNING 
SYSTEM (EGPWS) 
The following limitations are applicable to the Enhanced Ground 
Proximity Warning System (EGPWS): 
− The Allied-Signal Enhanced Ground Proximity Warning System 
Pilot’s Guide, Document Number 060-4241-000, March 1997 
edition (or later revision of the m anual) or certification authority 
accepted Operating Manual, must be immediately available to the 
flight crew. 
− Allied-Signal Application Software version 202 and Configuration 
Software version 202 or later must be installed. 
− Navigation is not to be predicated on the use of the Terrain 
Awareness Display. 
− The EGPWS displays and alerting algorithms prior version              
-213-213 currently do not account for man-made obstacles. 
− Pilots should inhibit the Terrain Awareness Alerting and Display 
function by pressing the TERRAIN SYS OVRD button when within 
15 NM of takeoff, approach, or l anding at an airport when any of 
the following conditions apply: 
− The airport has no approved instrument approach procedure. 
− The airport is not included in the Allied Signal data base. 
− The longest runway is less than 1070 m (3500 ft) in length. 
− Terrain Awareness Alerting and Display functionality must be 
manually inhibited when the flight crew knows in advance that: 
− An approach to an airport not included in the EGPWS database 
will be performed; 
− GPS is failed; 
− QFE operation is the altimeter operational mode below the 
transition altitude on approach into an airport which is more 
than 200 ft above or below Sea Level (not applicable to 
EGPWS software version 216 and on with FMS Honeywell or 
FMS Universal Post Mod.SB145-34-0112).

### Page 13

(No text on this page.)

### Page 14

LIMITATIONS AIRPLANE 
OPERATIONS 
MANUAL  
 
1-01-30 
Page 
1 
Code 
02  TEMPORARY REVISION 40.2
 
AOM-145/1114 
ENHANCED GROUND PROXIMITY WARNING 
SYSTEM (EGPWS) 
The following limitations are applicable to the Enhanced Ground 
Proximity Warning System (EGPWS): 
− The Allied-Signal Enhanced Ground Proximity Warning System 
Pilot’s Guide, Document Number 060-4241-000, March 1997 
edition (or later revision of the manual) or EASA accepted 
Operating Manual, must be immediately available to the flight crew. 
− Navigation is not to be predicated on the use of the Terrain 
Awareness Display. 
− The EGPWS displays and alerting algorithms prior version              
-213-213 currently do not account for man-made obstacles. 
− Pilots should inhibit the Terrain Awareness Alerting and Display 
function by pressing the TERRAIN SYS OVRD button when within 
15 NM of takeoff, approach, or l anding at an airport when any of 
the following conditions apply: 
- The airport has no approved instrument approach procedure. 
- The longest runway is less than 1070 m in length. 
- The airport is not included in the Allied Signal data base. 
− Terrain Awareness Alerting and Display functionality must be 
manually inhibited when the flight crew knows in advance that: 
- An approach to an airport not included in the EGPWS database 
will be performed; 
- GPS is failed; 
- QFE operation is the altimeter operational mode below the 
transition altitude on approach into an airport which is more than 
200 ft above or below Sea Level (not applicable to EGPWS 
software version 216 and on with FMS Honeywell or FMS 
Universal Post Mod.SB145-34-0112).

### Page 15

AIRPLANE 
OPERATIONS 
MANUAL 
LIMITATIONS 
 
 
TEMPORARY REVISION 40.2 1-01-50 
Page
2
Code
03
 
AOM-145/1114  
CAUTION: ON GROUND, DO NOT RELY ON VISUAL ICING 
EVIDENCE OR ICE DETECTOR ACTUATION TO TURN 
ON THE ANTI-ICING SYSTEM. USE THE TEMPERATURE 
AND VISUAL MOISTURE CRITERIA AS SPECIFIED 
ABOVE. DELAYING THE USE OF THE ANTI-ICING 
SYSTEM UNTIL ICE BUILD-UP  IS VISIBLE FROM THE 
COCKPIT MAY RESULT IN ICE INGESTION AND 
POSSIBLE ENGINE DAMAGE OR FLAME-OUT. 
 
WINDSHIELD WIPER OPERATION  (IF APPLICABLE)   
(AFM PROCEDURES) 
Maximum Airspeed for Windshield Wiper Operation ......170 KIAS

### Page 16

(No text on this page.)

### Page 17

(No text on this page.)

### Page 18

LIMITATIONS 
 
AIRPLANE 
OPERATIONS 
MANUAL 
 
 
1-01-80 
Page 
1 
Code 
02  TEMPORARY REVISION 40.2
 
AOM-145/1114  
CAT II OPERATION WITH PRIMUS 1000 
AUTOMATIC FLIGHT CONTROL SYSTEM 
MINIMUM EQUIPMENT REQUIRED 
The performance of Category II approaches requires that the following 
equipment and instruments be in proper operating conditions: 
− 2 Attitude and Heading Reference Systems or 2 Inertial 
Reference Systems; 
− 1 Yaw Damper System; 
− 1 Autopilot; 
− 2 Flight Director Systems; 
− 2 Primary Flight Displays (PFD); 
− Windshield Wipers; 
NOTE: For airplanes Pre-Mod. SB 145-30-0055 and Post-Mod 
SB 145-30-0054 (or with an equivalent modification 
factory incorporated), the Rain Repellent Coating replace 
the Windshield Wipers. Approved Rain Repellent 
Coatings are listed in AMM chapter 30-41-04. 
− 2 VHF/NAV Systems; 
− 1 VHF/COMM System; 
− Both Engines; 
− Cat II Checklist Logic; 
− 1 Electrical Trim System; 
− 1 Radio Altimeter; 
− 1 Ground Proximity Warning System (GPWS or EGPWS); 
− 1 Aural Warning Unit (AWU) Channel; 
− 2 Air Data Systems (ADS); 
− 1 Standby Attitude Indicator; 
− 1 Standby Airspeed Indicator; 
− 1 Standby Altimeter. 
NOTE: Cat II operation with autopilot engaged shall be performed by 
the pilot who has the Flight Director coupled to the autopilot.

### Page 19

(No text on this page.)

### Page 20

SUPPLEMENTARY 
PROCEDURES 
HIGH ALTITUDE 
OPERATION 
AIRPLANE 
OPERATIONS 
MANUAL 
 
 
1-02-87 
Page 
1 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114  
HIGH ALTITUDE OPERATION 
 
The information presented herein is only applicable to airplanes 
properly equipped for takeoff and landing operation above 8000 ft.  
Airplanes properly equipped accomplished any of the following Service 
Bulletins or have an equivalent modification factory incorporated:  
- SB 145-00-0031  
- SB 145-00-0033 
- SB 145-21-0050 
 
NOTE: During high altitude operations, at least one pilot is required to 
use oxygen continuously, until t he cabin altitude has reached 
8000 ft. 
BEFORE START 
Pressurization ............................................................... 8000 FT 
If flying from an airport above 8000 ft: 
High Altitude Mode................................................... ON 
Check that HI ALT LDG-T/O advisory message is displayed on 
the EICAS. 
Crew Oxygen Mask.................................................. DON 
CLIMB 
When cabin altitude is below 9700 ft: 
High Altitude Mode...................................................OFF 
Check that HI ALT LDG-T/O advisory message is no longer 
displayed the EICAS. 
DESCENT 
Pressurization ............................................................... SET 
Set the destination airport altitude. 
If flying in an airport above 8000 ft: 
High Altitude Mode................................................... ON 
Check that HI ALT LDG-T/O advisory message is displayed on 
the EICAS. 
Crew Oxygen Mask.................................................. DON

### Page 21

(No text on this page.)

### Page 22

ABNORMAL 
PROCEDURES 
AIRPLANE 
OPERATIONS 
MANUAL  
 
1-03-56 
Page 
1 
Code 
02  TEMPORARY REVISION 40.2
 
AOM-145/1114  
AIR CONDITIONING, PNEUMATICS AND 
PRESSURIZATION 
BLEED LOW TEMPERATURE 
EICAS Caution: BLD 1 (2) LOW TEMP 
LIGHT:  Master Caution 
INDICATION: Pointer on MFD may be out of view or indication may be 
amber. 
If temperature indication on MFD (E CS and Pneumatic Page) is in the 
green range or the pointer is out of view, disregard the message. 
Monitor the bleed temperature. 
 
If the pointer on MFD indicates low temperature (white range): 
Associated Thrust Lever ..........................................ADVANCE 
Adjust associated Thrust Lever until the message disappears or 
until the pointer of the failed side reaches the green range or the 
remaining pointer. 
Advancing Thrust Lever until 86% N2 represents normal system 
condition. 
If the message persists or if the MFD is not available: 
Associated Bleed ..................................................... CLOSE 
Altitude .....................................................................MAX 25000 ft 
MINIMUM MEA 
WARNING: IF IN ICING CONDITIONS, REFER TO SINGLE 
ENGINE OR SINGLE BLEED OPERATION IN ICING 
CONDITIONS PROCEDURE. 
If the message persists, avoid or exit icing conditions. 
NOTE: Ice Detection Override Knob must be set to ALL during at least 
2 minutes either after exiting icing conditions or after ICE 
CONDITION advisory message has disappeared.

### Page 23

(No text on this page.)

### Page 24

ABNORMAL 
PROCEDURES 
AIRPLANE 
OPERATIONS 
MANUAL  
 
1-03-56 
Page 
1 
Code 
03  TEMPORARY REVISION 40.2
 
AOM-145/1114  
AIR CONDITIONING, PNEUMATICS AND 
PRESSURIZATION 
BLEED LOW TEMPERATURE 
EICAS Caution: BLD 1 (2) LOW TEMP  
LIGHT:  Master Caution 
INDICATION: Pointer on MFD may be out of view or indication may be 
amber. 
If temperature indication on MFD (ECS and Pneumatic Page) is in the 
green range or the pointer is out of view, disregard the message. 
Monitor the bleed temperature. 
If the pointer on MFD indicates low temperature (white range): 
Associated Thrust Lever ..........................................ADVANCE 
Adjust associated Thrust Lever until the message disappears or 
until the pointer of the failed side reaches the green range or the 
remaining pointer. 
Advancing Thrust Lever until 86% N2 represents normal system 
condition. 
If the message persists or if the MFD is not available: 
Associated Bleed ..................................................... CLOSE 
Altitude .....................................................................MAX 25000 ft 
MINIMUM MEA 
WARNING: IF IN ICING CONDITIONS, REFER TO SINGLE 
ENGINE OR SINGLE BLEED OPERATION IN ICING 
CONDITIONS PROCEDURE. 
If the message persists, avoid or exit icing conditions. 
NOTE: Ice Detection Override Knob must be set to ALL at least 
2 minutes after exiting icing conditions or after ICE 
CONDITION advisory message has disappeared.

### Page 25

AIRPLANE 
OPERATIONS 
MANUAL 
ABNORMAL 
PROCEDURES 
 
TEMPORARY REVISION 40.2 1-03-57 
Page
6
Code
04
 
 
AOM-145/1114  
ICE DETECTOR FAIL 
EICAS CAUTION: ICE DET 1(2) FAIL or ICE DETECTORS FAIL 
LIGHT:  Master Caution 
Use visual cues (ice accretion on windshield and, if installed, on 
windshield wipers) and temperature criteria to determine whether icing 
conditions exist. When flying in icing conditions: 
Ice Detection Override Knob ................................... ALL 
After positively exiting icing conditions: 
Ice Detection Override Knob ................................... AUTO 
NOTE: - Icing conditions may exist inflight when Total Air 
Temperature (TAT) is 10°C or below and visible moisture in 
any form is present (such as cl ouds, fog with visibility of one 
mile or less, rain, snow, sleet, and ice crystals). 
- Ice Detection Override Knob must be kept at ALL during at 
least 2 minutes either after exiting icing conditions or after 
ICE CONDITION advisory message has disappeared. In 
such condition, caution message NO ICE-A/I ON may be 
presented, and must be disregarded. 
WINDSHIELD HEATING FAILURE 
EICAS CAUTION: W/S 1 (or 2) HEAT FAIL 
LIGHT:  Master Caution 
Confirm the failed side. 
Associated Windshield Heating .................................... OFF

### Page 26

(No text on this page.)

### Page 27

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
1
Code
01
 
 
AOM-145/1114 
GROUND RESETS 
The purpose of this chapter is to provide flight crew with information 
and procedures to clear nuisance EICAS messages and 
miscellaneous nuisance faults. 
This chapter does not cover all messages or faults that may be 
detected on the airplane. Any message or fault not covered by this 
document must be reported to the maintenance personnel. 
Standards procedures must  be established to instruct the flight crew 
how to proceed when: 
− Nuisance message is presented, or 
− Fault is presented before starting to follow this chapter after 
dispatch. 
These procedures may vary for different airports. 
This chapter is organized in a four-column table, as follows: 
− ATA column: gives the ATA number for the related message or 
fault. 
− MESSAGE or CONDITION column: pr ovides the messages or fault 
condition, alphabetically ordered. 
− LOCATION column: indicates the location of the fault or 
annunciation. 
− PROCEDURES column: provides the proper procedures required 
to clear the nuisance EICAS message or fault. It may also provide 
the effectivity of the procedure or  Fault Condition in which the 
procedure applies. 
This chapter is based on the FAULT ISOLATION MANUAL (FIM). 
Therefore, in case a discrepancy  is found between this chapter and 
FIM, the FIM must prevail. 
NOTE: This chapter should be used for reference only. Special 
approval from regulatory authorities must be granted to use the 
information contained herein.

### Page 28

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
2 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
LIMITATIONS 
This chapter shall be used under the following condition: 
− Airplane on the ground with parking brake set. 
− Each procedure may be performed only once per flight leg. If the 
nuisance EICAS message or fault is not cleared, if applicable, the 
maintenance personnel must be notified to clear the condition. 
− Effectivity and Fault Condition mu st be observed. Ground Resets 
Procedures should be accomplished only if the applicable effectivity 
and fault conditions are satisfied. Applicable effectivity and fault 
conditions are listed preceding the procedures. Those procedures 
that do not have effectivity and fault conditions listed preceding the 
procedures can be accomplished to every model and conditions, 
observing the preceding items.

### Page 29

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
3
Code
01
 
 
AOM-145/1114 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
34 
Absence of 
ADF 1 
bearing 
information 
on the 
RMU and 
on the PFD 
and MFD 
ADF 
(1) Set the cursor of RMU 1 to the 
ADF 1 window. 
(2) Do the test of the frequency 
selection: 
(a) Put the cursor on the selected 
frequency code. 
(b) Turn the dual concentric 
knobs. 
A frequency code can be set. 
(3) Do the self-test: 
(a) Set the RMU 1 to the ADF 1 
window. 
(b) Push and hold the RMU TST 
function key. 
On the RMU, the ADF 1 
window shows: 
− TEST and ADF TEST 
(amber). 
− TEST (amber) and ADF 
PASS (green), at the end of 
the test cycle. 
NOTE: An ADF ERR (red) is the 
indication that the selected ADF 
is defective. 
(4) Do the ADF test: 
(a) Set RMU 1 to the ADF 1 
window. 
(b) Tune in an ADF station.  
Make sure that the sensitivity 
and bearing are correct. 
(5) Do steps (1), (2), (3), and (4) 
again for ADF 2, on RMU2.

### Page 30

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
4 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
34 
Absence of 
ADF 2 
bearing 
information 
on the RMU 
and on the 
PFD and 
MDF 
ADF 
(1) Set the cursor of RMU 1 to the 
ADF 1 window. 
(2) Do the test of the frequency 
selection: 
(a) Put the cursor on the selected 
frequency code. 
(b) Turn the dual concentric 
knobs. 
A frequency code can be set. 
(3) Do the self-test: 
(a) Set the RMU to the ADF 1 
window. 
(b) Push and hold the RMU TST 
function key. 
On the RMU, the ADF 1 
window shows: 
− TEST and ADF TEST 
(amber). 
− TEST (amber) and ADF 
PASS (green), at the end of 
the test cycle. 
NOTE: An ADF ERR (red) is the 
indication that the selected ADF 
is defective. 
(4) Do the ADF test: 
(a) Set RMU 1 to the ADF 1 
window. 
(b) Tune in an ADF station.  
Make sure that the sensitivity 
and bearing are correct. 
(5) Do steps (1), (2), (3), and (4) 
again for ADF 2, on RMU2.

### Page 31

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
5
Code
01
 
 
AOM-145/1114 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
34 
Absence of 
DME 1 
distance 
information 
on the RMU 
and on the 
PFD and 
MFD 
DME 
(1) On RMU 1, push the DME 
function key. 
(2) Move the cursor of RMU 1 to the 
DME 1 window. 
(3) Do the test of frequency 
selection: 
(a) Put the cursor on the selected 
frequency code. 
(b) Turn the dual concentric 
knobs. 
A frequency code can be set. 
(4) Do the self-test: 
(a) Set the RMU 1 to the DME 1 
window. 
(b) Push and hold the RMU TST 
function key. 
On the RMU, the DME 1 
window shows: 
− TEST and DME TEST 
(amber). 
− TEST (amber) and DME 
PASS (green), at the end of 
the test cycle. 
NOTE: A DME ERR (red) is the 
indication that the selected DME 
is defective. 
(5) Do steps (1), (2), (3), and (4) 
again for DME 2, on RMU 2. 
(6) Do the DME test: 
(a) Set RMU 1 to the DME 1 
window. 
(b) Tune in to station of DME. 
Make sure of the correct 
distance and identification. 
(c) Set RMU 2 to the DME 2 
window. 
(d) Tune in to DME station. 
Make sure of the correct 
distance and identification.

### Page 32

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
6 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
34 
Absence of 
DME 2 
distance 
information 
on the RMU 
and on the 
PFD and 
MFD 
DME 
(1) On RMU 1, push the DME 
function key. 
(2) Move the cursor of RMU 1 to the 
DME 1 window. 
(3) Do the test of frequency 
selection: 
(a) Put the cursor on the selected 
frequency code. 
(b) Turn the dual concentric 
knobs. 
A frequency code can be set. 
(4) Do the self-test: 
(a) Set the RMU 1 to the DME 1 
window. 
(b) Push and hold the RMU TST 
function key. 
On the RMU, the DME 1 
window shows: 
− TEST and DME TEST 
(amber). 
− TEST (amber) and DME 
PASS (green), at the end of 
the test cycle. 
NOTE: A DME ERR (red) is the 
indication that the selected DME 
is defective. 
(5) Do steps (1), (2), (3), and (4) 
again for DME 2, on RMU 2. 
(6) Do the DME test: 
(a) Set RMU 1 to the DME 1 
window. 
(b) Tune in to station of DME. 
Make sure of the correct 
distance and identification. 
(c) Set RMU 2 to the DME 2 
window. 
(d) Tune in to DME station. 
Make sure of the correct 
distance and identification.

### Page 33

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
7
Code
01
 
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
24 
Absence of 
electrical 
power at 
some buses
GPU Set the ELEC PWR switch, on the maintenance panel, to RESET. 
23 
ACARS/ 
DMU failure 
message on 
FMS 
ACARS 
Check if the fault occurred during the 
airplane power-up. 
NOTE: The CMU takes 
approximately 1 minute or 2 minutes 
to restart. During this time, the CDU 
displays ACARS DMU FAILED. 
27 
Aileron – No 
roll control 
through the 
switch 
AILERON
Do a roll trim test through the roll trim 
switch: 
(1) Push the roll trim switch to the 
LWD position for approximately 
3 seconds. The roll trim system is 
automatically deactivated in 
3 ± 0.3 seconds. 
(2) Push the roll trim switch to the 
RWD position for approximately 
3 seconds. The roll trim system is 
automatically deactivated in 
3 ± 0.3  seconds.

### Page 34

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
8 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
34 
ALT Flag on 
the ISIS 
(SMITHS 
and 
THALES) 
ISIS 
(1) On the circuit breaker panel, open 
and close the INTEG STBY circuit 
breaker. 
NOTE: Before turning on the 
ISIS, make sure that there is no 
dynamic pressure applied to 
Pitot/Static 3. It must be 
equivalent to an airspeed equal to 
or greater than 60 knots. 
The airplane must be maintained 
stationary during the ISIS 
initialization. 
(2) The display shows an initialization 
page for 70 seconds (ISIS 
SMITHS) or for 90 seconds (ISIS 
THALES). 
(3) Wait until the ISIS completes its 
initialization. 
34 
ATT Flag 
on the ISIS 
(SMITHS 
and 
THALES) 
ISIS 
(1) On the circuit breaker panel, open 
and close the INTEG STBY circuit 
breaker. 
NOTE: Before turning on the 
ISIS, make sure that there is no 
dynamic pressure applied to 
Pitot/Static 3. It must be 
equivalent to an airspeed equal to 
or greater than 60 knots. 
The airplane must be maintained 
stationary during the ISIS 
initialization. 
(2) The display shows an initialization 
page for 70 seconds (ISIS 
SMITHS) or for 90 seconds (ISIS 
THALES). 
(3) Wait until the ISIS completes its 
initialization.

### Page 35

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
9
Code
01
 
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
34 
CAGE Flag 
on the ISIS
(THALES) 
ISIS 
(1) Push the CAGE button to cage 
the Integrated Standby 
Instrument System (ISIS) and do 
not move the ISIS during this 
phase. 
NOTE: The "ATT 10s" indication 
replaces the ATT CAGE flag to 
show that the ISIS is in the 
attitude reset (caging) phase. 
In flight, the pilot must maintain 
the airplane in straight and level 
flight and at constant speed 
before pushing the CAGE button 
during this phase. 
(2) Make sure that the attitude 
function has been set to the true 
value in stabilized condition. 
31 
CAS 
Message 
displayed 
on the PFD 
IC-600 
On the copilot’s reversionary panel, 
set the MFD selector to the EICAS 
position. To check which the 
discrepant message is, compare the 
messages on the copilot’s MFD with 
the ones presented on the EICAS. 
In a discrepant message on the 
EICAS: 
− Open the IC-600 1 circuit breaker, 
wait a few seconds, and close it 
back. Wait for the IC system 
initialization. Do the comparison 
again.

### Page 36

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
10 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
27 
Directional 
Trim 
Locked 
Rudder 
Trim 
Pressurize the hydraulic system. 
Do the operational check of the yaw 
trim: 
− Move the YAW TRIM switch to 
the LEFT position. 
On the EICAS display, the arrow 
of the YAW TRIM indication 
moves to the left. 
NOTE: The system cycle is 
limited in 3 seconds, after this 
time you must to release the 
switch and move it again to get 
another cycle. 
− Release the YAW TRIM switch, it 
goes to neutral position by itself. 
On the EICAS display, the arrow 
of the YAW TRIM indication 
remains at last position. 
− Move the YAW TRIM switch to 
the RIGHT position. 
On the EICAS display, the arrow 
of the YAW TRIM indication goes 
from LEFT to RIGHT position.

### Page 37

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
11
Code
01
 
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
27 
Directional 
Trim 
Locked 
Yaw Trim 
Pressurize the hydraulic system. 
Do the operational check of the yaw 
trim: 
− Move the YAW TRIM switch to 
the LEFT position. 
On the EICAS display, the arrow 
of the YAW TRIM indication 
moves to the left. 
NOTE: The system cycle is 
limited in 3 seconds, after this 
time you must to release the 
switch and move it again to get 
another cycle. 
− Release the YAW TRIM switch, it 
goes to neutral position by itself. 
On the EICAS display, the arrow 
of the YAW TRIM indication 
remains at last position. 
− Move the YAW TRIM switch to 
the RIGHT position. 
On the EICAS display, the arrow 
of the YAW TRIM indication goes 
from LEFT to RIGHT position.

### Page 38

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
12 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
28 
FCU X 
ARINC 429 
message 
appears on 
the repeater 
indicator 
panel 
FCU 
Do the electrical fuel quantity 
indication check. 
Transitory condition of the wing fuel 
conditioning unit. 
On the repeater indicator panel, set 
the toggle switch to the TEST 
position and clear the fault message.
28 
FCU X FAIL 
message on 
the repeater 
indicator 
panel 
FCU 
Do the electrical fuel quantity 
indication check. 
Transitory condition of the wing fuel 
conditioning unit. 
On the repeater indicator panel, set 
the toggle switch to the TEST 
position and clear the fault message.
34 
HDG Flag 
on the ISIS 
(SMITHS 
and 
THALES) 
ISIS 
(1) On the circuit breaker panel, open 
and close the INTEG STBY circuit 
breaker. 
NOTE: Before turning on the 
ISIS, make sure that there is no 
dynamic pressure applied to 
Pitot/Static 3. It must be 
equivalent to an airspeed equal to 
or greater than 60 knots. 
The airplane must be maintained 
stationary during the ISIS 
initialization. 
(2) The display shows an initialization 
page for 70 seconds (ISIS 
SMITHS) or for 90 seconds (ISIS 
THALES). 
(3) Wait until the ISIS completes its 
initialization.

### Page 39

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
13
Code
01
 
 
AOM-145/1114 
 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
34 M Flag on the ISIS ISIS 
(1) On the circuit breaker panel, open 
and close the INTEG STBY circuit 
breaker. 
NOTE: Before turning on the 
ISIS, make sure that there is no 
dynamic pressure applied to 
Pitot/Static 3. It must be 
equivalent to an airspeed equal to 
or greater than 60 knots. 
The airplane must be maintained 
stationary during the ISIS 
initialization. 
(2) The display shows an initialization 
page for 90 seconds. 
(3) Wait until the ISIS completes its 
initialization. 
34 
MAINT 
Indication 
on the ISIS 
ISIS 
(1) On the circuit breaker panel, open 
and close the INTEG STBY circuit 
breaker. 
NOTE: Before turning on the 
ISIS, make sure that there is no 
dynamic pressure applied to 
Pitot/Static 3. It must be 
equivalent to an airspeed equal to 
or greater than 60 knots. 
The airplane must be maintained 
stationary during the ISIS 
initialization. 
(2) The display shows an initialization 
page for 90 seconds. 
(3) Wait until the ISIS completes its 
initialization.

### Page 40

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
14 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
28 
MFD shows 
dashes 
instead of 
wing fuel 
quantity 
FCU 
Get access to the maintenance 
panel. Set the fuel page on the MFD.
Move the "FUEL QTY IND" toggle 
switch on the maintenance panel. 
(1) The EICAS display shows these 
messages and indications: 
− FUEL 1-2 LO LEVEL 
(WARNING). 
− TANK 1-2 shows 1130 kg ± 
10 kg (2500 lb). 
(2) The MFD shows these 
indications: 
− TANK 1 – 1130 kg ± 10 kg 
(2500 lb). 
− TANK 2 – 1130 kg ± 10 kg 
(2500 lb). 
− TOTAL – 2260 kg (5000 lb). 
(3) The warning lights flash. 
(4) The aural warning operates (bell).
NOTE: After 10 seconds, the 
preceding indications go back to 
the normal condition. 
Press one of the master warning 
lights to stop the lights.

### Page 41

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
15
Code
01
 
 
AOM-145/1114 
 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
34 SPD Flag on the ISIS ISIS 
(1) On the circuit breaker panel, open 
and close the INTEG STBY circuit 
breaker. 
NOTE: Before turning on the 
ISIS, make sure that there is no 
dynamic pressure applied to 
Pitot/Static 3. It must be 
equivalent to an airspeed equal to 
or greater than 60 knots. 
The airplane must be maintained 
stationary during the ISIS 
initialization. 
(2) The display shows an initialization 
page for 90 seconds. 
(3) Wait until the ISIS completes its 
initialization. 
34 
SSEC 
Annunciation
on the ISIS 
ISIS 
(1) On the circuit breaker panel, open 
and close the INTEG STBY circuit 
breaker. 
NOTE: Before turning on the 
ISIS, make sure that there is no 
dynamic pressure applied to 
Pitot/Static 3. It must be 
equivalent to an airspeed equal to 
or greater than 60 knots. 
The airplane must be maintained 
stationary during the ISIS 
initialization. 
(2) The display shows an initialization 
page for 90 seconds. 
(3) Wait until the ISIS completes its 
initialization.

### Page 42

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
16 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
22 
The rudder 
servo motor 
does not 
actuate 
IC-600 
(1) Energize the airplane with the 
External DC Power supply. 
(2) Pressurize the hydraulic system. 
Operational check of the Yaw 
trim: 
(a) Move the YAW TRIM switch 
to the LEFT position. 
On the EICAS display, the 
arrow of the YAW TRIM 
indication moves to the left. 
NOTE: The system cycle time 
is limited in 3 seconds, after 
this time you must to release 
the switch and move it again 
to get another cycle. 
(b) Release the YAW TRIM 
switch, it goes to neutral 
position by itself. 
On the EICAS display, the 
arrow of the YAW TRIM 
indication remains at last 
position. 
(c) Move the YAW TRIM switch 
to the RIGHT position. 
On the EICAS display, the 
arrow of the YAW TRIM 
indication goes from LEFT to 
RIGHT position. 
(3) Release the pressure of the 
hydraulic system.

### Page 43

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
17
Code
01
 
 
AOM-145/1114 
 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
34 
VMO/MMO 
Flag on the 
ISIS 
ISIS 
(1) On the circuit breaker panel, open 
and close the INTEG STBY circuit 
breaker. 
NOTE: Before turning on the 
ISIS, make sure that there is no 
dynamic pressure applied to 
Pitot/Static 3. It must be 
equivalent to an airspeed equal to 
or greater than 60 knots. 
The airplane must be maintained 
stationary during the ISIS 
initialization. 
(2) The display shows an initialization 
page for 90 seconds. 
(3) Wait until the ISIS completes its 
initialization. 
23 
VOICE 
RECORDER
Record all 
crew voice 
communicati
on 
inoperative 
CVR 
CVR Impact switch lamp on? 
Press the Impact switch RESET 
pushbutton.

### Page 44

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
18 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
34 AHRS 1 ATT MODE EICAS 
(1) After the airplane is brought to a 
stop at the ramp or hangar, power 
off the AHRS 1. 
Open the circuit breaker AHRS 1 
(C2). 
(2) Reapply power and try to align 
the AHRS in a normal fashion. 
34 AHRS 2 ATT MODE EICAS 
(1) After the airplane is brought to a 
stop at the ramp or hangar, power 
off the AHRS 2. 
Open the circuit breaker AHRS 2 
(D33). 
(2) Reapply power and try to align 
the AHRS in a normal fashion.

### Page 45

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
19
Code
01
 
 
AOM-145/1114 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
34 AHRS 1 FAIL EICAS 
(1) Enter the correct present position. 
For airplanes with single or dual 
Honeywell FMS: 
NOTE: Operator can use either 
the FMS CDU or the bezel 
pushbuttons of the pilot’s MFD to 
enter the present position. 
(a) FMS CDU: 
Push the NAV mode key and 
the NEXT function key (NAV 
INDEX 2/2 page comes into 
view). 
Push the POS INIT (3L) left 
line select key (POS INIT 1/1 
page comes into view). 
Push the LOAD (2R) right line 
select key to update the FMS 
position with the last saved 
position (FMS CDU shows the 
LOADED POSITION 
coordinates). 
Bezel Pushbuttons: 
Make sure that the airplane is 
in the ground configuration. 
On main menu of the pilot’s 
MFD, use the bezel 
pushbuttons to select the 
PPOS INIT option (pilot’s MFD 
shows the present position 
initialization menu). 
NOTE: From this menu 
operator can: 
− Confirm that the EFIS 
stored present position 
(PPOS) is correct, and push 
the ENT pushbutton, or 
 
(continued)

### Page 46

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
20 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
34 
AHRS 1 
FAIL  
(continued) 
EICAS 
(continued) 
− Operator can change the 
present position coordinates 
via the bezel pushbuttons 
and the data set knob. 
(b) After the present coordinates 
are set, push the ENT 
pushbutton to send the 
coordinates to the AH-900 
computer. 
For airplanes with single or dual 
Universal FMS: 
NOTE: Operator can use either 
the FMS CDU or the bezel 
pushbuttons of the pilot’s MFD to 
enter the present position. 
(a) FMS CDU: 
On the FMS CDU, on the INIT 
1/1 page, push the ACCEPT 
line select key to update the 
FMS position. 
Bezel pushbuttons: 
Make sure that the airplane is 
in the ground configuration. 
On main menu of the pilot’s 
MFD, use the bezel 
pushbuttons to select the 
PPOS INIT option (pilot’s MFD 
shows the present position 
initialization menu). 
NOTE: From this menu 
operator can: 
− Confirm that the EFIS 
stored present position 
(PPOS) is correct, and push 
the ENT pushbutton, or 
 
(continued)

### Page 47

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
21
Code
01
 
 
AOM-145/1114 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
34 
AHRS 1 
FAIL 
(continued) 
EICAS 
(continued) 
− Operator can change the 
present position coordinates 
via the bezel pushbuttons 
and the data set knob. 
(b) After the present coordinates 
are set, push the ENT 
pushbutton to send the 
coordinates to the AH-900 
computer. 
NOTE: At the end of the 
alignment, the AHRU 
conducts an alignment-
performance test on the 
entered latitude. If the entered 
does not pass the alignment-
performance test, the AHRS 1 
ALN FAULT message shows 
on the EICAS display. If a 
subsequent entry of the same 
latitude does not pass the 
alignment-performance test, 
the AHRS 1 FAIL message 
shows on the EICAS display. 
Under the preceding 
conditions, the AHRU still 
accepts latitude entries. If an 
entry passes the alignment-
performance test: 
− AHRS 1 FAIL message 
goes out of view, and 
− AHRU clears the bits that 
were set to indicate the 
failure. 
(2) Wait until the alignment is 
completed.

### Page 48

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
22 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
34 AHRS 2 FAIL EICAS 
(1) Enter the correct present position.
For airplanes with single or dual 
Honeywell FMS: 
NOTE: Operator can use either 
the FMS CDU or the bezel 
pushbuttons of the pilot’s MFD to 
enter the present position. 
(a) FMS CDU: 
Push the NAV mode key and 
the NEXT function key (NAV 
INDEX 2/2 page comes into 
view). 
Push the POS INIT (3L) left 
line select key (POS INIT 1/1 
page comes into view). 
Push the LOAD (2R) right line 
select key to update the FMS 
position with the last saved 
position (FMS CDU shows the 
LOADED POSITION 
coordinates). 
(b) Bezel Pushbuttons: 
Make sure that the airplane is 
in the ground configuration. 
On main menu of the pilot’s 
MFD, use the bezel 
pushbuttons to select the 
PPOS INIT option (pilot’s MFD 
shows the present position 
initialization menu). 
NOTE: From this menu 
operator can: 
− Confirm that the EFIS 
stored present position 
(PPOS) is correct, and push 
the ENT pushbutton, or  
 
(continued)

### Page 49

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
23
Code
01
 
 
AOM-145/1114 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
34 
AHRS 2 
FAIL 
(continued) 
EICAS 
(continued) 
− Operator can change the 
present position coordinates 
via the bezel pushbuttons 
and the data set knob. 
(c) After the present coordinates 
are set, push the ENT 
pushbutton to send the 
coordinates to the AH-900 
computer. 
For airplanes with single or dual 
Universal FMS: 
NOTE: Operator can use either 
the FMS CDU or the bezel 
pushbuttons of the pilot’s MFD to 
enter the present position. 
(a) FMS CDU: 
On the FMS CDU, on the INIT 
1/1 page, push the ACCEPT 
line select key to update the 
FMS position. 
(b) Bezel pushbuttons: 
Make sure that the airplane is 
in the ground configuration. 
On main menu of the pilot’s 
MFD, use the bezel 
pushbuttons to select the 
PPOS INIT option (pilot’s MFD 
shows the present position 
initialization menu). 
NOTE: From this menu 
operator can: 
− Confirm that the EFIS 
stored present position 
(PPOS) is correct, and push 
the ENT pushbutton, or  
 
(continued)

### Page 50

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
24 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
34 
AHRS 2 
FAIL 
(continued) 
EICAS 
(continued) 
− Operator can change the 
present position coordinates 
via the bezel pushbuttons 
and the data set knob. 
(c) After the present coordinates 
are set, push the ENT 
pushbutton to send the 
coordinates to the AH-900 
computer. 
NOTE: At the end of the 
alignment, the AHRU 
conducts an alignment-
performance test on the 
entered latitude. If the entered 
does not pass the alignment-
performance test, the AHRS 1 
ALN FAULT message shows 
on the EICAS display. If a 
subsequent entry of the same 
latitude does not pass the 
alignment-performance test, 
the AHRS 1 FAIL message 
shows on the EICAS display. 
Under the preceding 
conditions, the AHRU still 
accepts latitude entries. If an 
entry passes the alignment-
performance test: 
− AHRS 1 FAIL message 
goes out of view, and 
− AHRU clears the bits that 
were set to indicate the 
failure. 
(2) Wait until the alignment is 
completed.

### Page 51

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
25
Code
01
 
 
AOM-145/1114 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
31 CHECK IC 2 SW  EICAS On the circuit breaker panel, open the IC 2 circuit breaker and close it after a few seconds. 
31 DAU 1A FAIL EICAS 
Check the SG pushbutton on the pilot 
Reversionary Panel. 
Is the SG pushbutton pressed when 
the DAU 1A FAIL message appears? 
YES 
− Open, and then, close the IC 2 
circuit breaker on the overhead 
circuit breakers panel. 
NO 
− Open the IC 1 circuit breaker on the 
overhead circuit breakers panel and 
the IC 1 circuit breaker on the 
backup relay box. 
− Close the IC 1 circuit breaker on the 
overhead circuit breakers panel and 
the IC 1 circuit breaker on the 
backup relay box.

### Page 52

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
26 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
31 DAU 1B FAIL EICAS 
Check the SG pushbutton on the pilot 
Reversionary Panel. 
Is the SG pushbutton pressed when 
the DAU 1B FAIL message appears? 
YES 
− Open, and then, close the IC 2 
circuit breaker on the overhead 
circuit breakers panel. 
NO 
− Open the IC 1 circuit breaker on the 
overhead circuit breakers panel and 
the IC 1 circuit breaker on the 
backup relay box. 
− Close the IC 1 circuit breaker on the 
overhead circuit breakers panel and 
the IC 1 circuit breaker on the 
backup relay box. 
31 DAU 2A FAIL EICAS 
Check the SG pushbutton on the pilot 
Reversionary Panel. 
Is the SG pushbutton pressed when 
the DAU 2A FAIL message appears? 
YES 
− Open, and then, close the IC 2 
circuit breaker on the overhead 
circuit breakers panel. 
NO 
− Open the IC 1 circuit breaker on the 
overhead circuit breakers panel and 
the IC 1 circuit breaker on the 
backup relay box. 
− Close the IC 1 circuit breaker on the 
overhead circuit breakers panel and 
the IC 1 circuit breaker on the 
backup relay box.

### Page 53

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
27
Code
01
 
 
AOM-145/1114 
 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
31 DAU 2B FAIL EICAS 
Check the SG pushbutton on the pilot 
Reversionary Panel. 
Is the SG pushbutton pressed when 
the DAU 2B FAIL message appears? 
YES 
− Open, and then, close the IC 2 
circuit breaker on the overhead 
circuit breakers panel. 
NO 
− Open the IC 1 circuit breaker on the 
overhead circuit breakers panel and 
the IC 1 circuit breaker on the 
backup relay box. 
− Close the IC 1 circuit breaker on the 
overhead circuit breakers panel and 
the IC 1 circuit breaker on the 
backup relay box. 
31 
DAU 1 
WRN 
MISCOMP 
EICAS 
Check the SG pushbutton on the pilot 
Reversionary Panel. 
Is the SG pushbutton pressed when 
the DAU 1 WRN MISCOMP message 
appears? 
YES 
− Open, and then, close the IC 2 
circuit breaker on the overhead 
circuit breakers panel. 
NO 
− Open the IC 1 circuit breaker on the 
overhead circuit breakers panel and 
the IC 1 circuit breaker on the 
backup relay box. 
− Close the IC 1 circuit breaker on the 
overhead circuit breakers panel and 
the IC 1 circuit breaker on the 
backup relay box.

### Page 54

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
28 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
31 
DAU 2 
WRN 
MISCOMP 
EICAS 
Check the SG pushbutton on the pilot 
Reversionary Panel. 
Is the SG pushbutton pressed when 
the DAU 2 WRN MISCOMP message 
appears? 
YES 
− Open, and then, close the IC 2 
circuit breaker on the overhead 
circuit breakers panel. 
NO 
− Open the IC 1 circuit breaker on the 
overhead circuit breakers panel and 
the IC 1 circuit breaker on the 
backup relay box. 
− Close the IC 1 circuit breaker on the 
overhead circuit breakers panel and 
the IC 1 circuit breaker on the 
backup relay box. 
34 DU 1 FAN FAIL EICAS On the circuit breaker panel, open and close PFD 1 circuit breaker (D13). 
34 DU 2 FAN FAIL EICAS On the circuit breaker panel, open and close MFD 1 circuit breaker (D23). 
34 DU 3 FAN FAIL EICAS On the circuit breaker panel, open and close EICAS/DISPLAY circuit breaker (C9). 
34 DU 4 FAN FAIL EICAS On the circuit breaker panel, open and close MFD 2 circuit breaker (D12). 
34 DU 5 FAN FAIL EICAS On the circuit breaker panel, open and close PFD 2 circuit breaker (D22). 
34 DU 1 OVHT EICAS 
Check if the DU 1 OVHT message 
appears for approximately 4 seconds 
on the EICAS and then disappears.

### Page 55

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
29
Code
01
 
 
AOM-145/1114 
 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
34 DU 2 OVHT EICAS 
Check if the DU 2 OVHT message 
appears for approximately 4 seconds 
on the EICAS and then disappears. 
34 DU 3 OVHT EICAS 
(1) On the pilot reversionary panel, 
rotate the MFD switch to the 
EICAS position. 
The EICAS screen shows on the 
MFD 1 display (DU 2). 
(2) Check if the DU 3 OVHT 
message appears for 
approximately 4 seconds on the 
EICAS (DU 2) and then 
disappears. 
If yes, on the pilot reversionary 
panel, rotate the MFD switch to 
the normal position. 
The EICAS screen shows on the 
EICAS display (DU 3). 
34 DU 4 OVHT EICAS 
Check if the DU 4 OVHT message 
appears for approximately 4 seconds 
on the EICAS and then disappears. 
34 DU 5 OVHT EICAS 
Check if the DU 5 OVHT message 
appears for approximately 4 seconds 
on the EICAS and then disappears. 
34 HGS FAIL EICAS 
Open the following circuit breakers 
and, after approximately 5 seconds, 
close them: 
− HCP (Location Tip: DC BUS 
1/CAT III/HCP) CB H8 
− HGC (Location Tip: DC BUS 
1/CAT III/HCG) CB H6 
− OHU (Location Tip: DC BUS 
1/CAT III/OHU). CB H7 
34 IRS 1 ATT MODE EICAS 
(1) After the airplane is brought to a 
stop at the ramp or hangar, power 
off IRS 1. 
(2) Reapply power and try to align 
IRS 1 in a normal fashion.

### Page 56

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
30 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
34 IRS 2 ATT MODE EICAS 
(1) After the airplane is brought to a 
stop at the ramp or hangar, power 
off IRS 2. 
(2) Reapply power and try to align 
IRS 2 in a normal fashion. 
34 IRS 1 FAIL EICAS 
(1) Set the MSU 1 rotary switch to 
ALIGN. 
(2) Enter the correct present position.
NOTE: The airplane must be 
maintained stationary during the 
IRS 1 alignment. 
(3) Wait until the alignment is 
complete. 
In case of IRS 1 FAIL message 
does not disappear: 
(a) Set the MSU 1 rotary switch to 
OFF. 
(b) On the overhead electrical 
panel, push the BACKUP 
pushbutton (the stripped bar 
illuminates). 
(c) On the overhead circuit 
breaker panel, open IRS 1 CB.
(d) On the overhead circuit 
breaker panel, open the 
following CBs: 
For single FMS installed: 
CDU, CMPTR, GPS. 
For dual FMS installed: 
CDU 1, CDU 2, FMC 1, 
FMC 2, GPS 1, and GPS 2. 
(e) Wait at least 3 seconds. 
(f) On the overhead electrical 
panel, push the BACKUP 
pushbutton again (the stripped 
bar extinguishes). 
(continued)

### Page 57

AIRPLANE 
OPERATIONS 
MANUAL 
GROUND SERVICING 
 
TEMPORARY REVISION 40.2 1-12-60 
Page
31
Code
01
 
 
AOM-145/1114 
  
ATA 
EICAS 
MESSAGE 
or 
CONDITION
LOCATION PROCEDURE 
34 IRS 1 FAIL (continued) EICAS 
(continued) 
(g) On the overhead circuit 
breaker panel, close IRS 1 
CB. 
(h) On the overhead circuit 
breaker panel, close the 
following CBs: 
For single FMS installed: 
CDU, CMPTR, GPS. 
For dual FMS installed: 
CDU 1, CDU 2, FMC 1, 
FMC 2, GPS 1, and GPS 2. 
(i) Set the MSU 1 rotary switch to 
ALIGN. 
(j) Enter the correct present 
position. 
NOTE: The airplane must be 
kept stationary during the 
IRS 1 alignment. 
(k) Wait until the alignment is 
complete. 
34 IRS 2 FAIL EICAS 
(1) Set the MSU 2 rotary switch to 
ALIGN. 
(2) Enter the correct present position. 
NOTE: The airplane must be 
maintained stationary during the 
IRS 2 alignment. 
(3) Wait until the alignment is 
complete. 
In case of IRS 2 FAIL message 
does not disappear: 
(a) Set the MSU 2 rotary switch to 
OFF. 
(b) On the overhead electrical 
panel, push the BACKUP 
pushbutton (the stripped bar 
illuminates). 
(continued)

### Page 58

GROUND SERVICING AIRPLANE 
OPERATIONS 
MANUAL  
 
1-12-60 
Page 
32 
Code 
01  TEMPORARY REVISION 40.2
 
AOM-145/1114 
 
ATA 
EICAS 
MESSAGE 
or 
CONDITION 
LOCATION PROCEDURE 
34 IRS 2 FAIL (continued) EICAS 
(continued) 
(c) On the overhead circuit 
breaker panel, open IRS 2 CB.
(d) On the overhead circuit 
breaker panel, open the 
following CBs: 
For single FMS installed: 
CDU, CMPTR, GPS. 
For dual FMS installed: 
CDU 1, CDU 2, FMC 1, 
FMC 2, GPS 1 and GPS 2. 
(e) Wait at least 3 seconds. 
(f) On the overhead electrical 
panel, push the BACKUP 
pushbutton again (the stripped 
bar extinguishes). 
(g) On the overhead circuit 
breaker panel, close IRS 2 
CB. 
(h) On the overhead circuit 
breaker panel, close the 
following CBs: 
For single FMS installed: 
CDU, CMPTR, GPS. 
For dual FMS installed: 
CDU 1, CDU 2, FMC 1, 
FMC 2, GPS 1 and GPS 2. 
(i) Set the MSU 2 rotary switch to 
ALIGN. 
(j) Enter the correct present 
position. 
NOTE: The airplane must be 
kept stationary during the IRS 
2 alignment. 
(k) Wait until the alignment is 
complete. 
27 RUD STOP DISAGREE EICAS Energize the airplane with the hydraulic power.

### Page 59

(No text on this page.)

### Page 60

PNEUMATICS 
AIR CONDITIONING 
AND PRESSURIZATION 
AIRPLANE 
OPERATIONS 
MANUAL 
 
 
2-14-15 
Page 
1 
Code 
02  TEMPORARY REVISION 40.2
 
AOM-145/1114  
PRESSURIZATION SYSTEM 
The information presented herein is only applicable to airplanes 
properly equipped for takeoff and landing operation above 8000 ft.  
Airplanes properly equipped accomplished any of the following Service 
Bulletins or have an equivalent modification factory incorporated:  
- SB 145-00-0031  
- SB 145-00-0033 
- SB 145-21-0050 
 
The Cabin Pressure Control Syst em (CPCS) controls the cabin 
pressure by regulating the cabin air exhaust rate supplied by the 
ECUs. 
The CPCS comprises two subsystems:  
- One digital electropneumatic subsystem (automatic mode). 
- One pneumatic subsystem (manual mode). 
Both subsystems comprise a digital controller, a manual controller, an 
electropneumatic outflow valve, a pneumatic outflow valve, an air filter, 
two pressure regulator valves, an ejector pump, two static ports, and a 
Cabin Pressure Acquisition Module (CPAM). 
Both outflow valves receive static pressure signals from static ports for 
overpressure relief and negative pressure relief functions, actuating 
pneumatic devices to inhibit airplane structural damage or injury in 
case of improper system operation.  The safety devices provide the 
following features: 
− Positive cabin differential pressure relief: 8.2 psi maximum. 
− Negative cabin differential pressure relief: - 0.3 psi. 
− Cabin altitude limitation (when in the auto mode): 15000 ft maximum. 
The system is normally operated in the automatic mode. The manual 
mode is used in case of automatic mode failure. 
The cabin air filter is provided to prevent nicotine and dust to enter the 
outflow valve chamber. 
Indications of cabin altitude, cabin differential pressure, and cabin 
altitude rate of change are presented on the EICAS.  
A caution message is presented on t he EICAS in case of automatic 
mode failure, requiring the crew to select the manual mode. 
The CPAM and CPCS have internal tolerances of ± 100 ft and ± 200 ft, 
respectively. Then, depending on these tolerances accumulation, the 
displayed cabin altitude may be increased up to 300 ft.

The text continues at https://openairdocs.org/service-documents/embraer/tr-40-2/file/54b158809b36.md?from=61

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.