# Fokker Service Bulletin SBF100-24-043: Revision 1

- Rights: © Fokker. Filed by the FAA in regulations.gov docket FAA-2012-0270; AD 2013-17-06 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Fokker Service Bulletin SBF100-24-043](https://openairdocs.org/service-documents/fokker/sbf100-24-043.md)
- Title as filed: U.S. DOT/FAA - SBF100-24-043, R1
- Pages: 29
- PDF: https://openairdocs.org/files/sha256/d9/e4/d9e4e7babe0f6c648a751408944c1732216243a301f78922a5115e43da07f2e6
- Page: https://openairdocs.org/service-documents/fokker/sbf100-24-043/file/d9e4e7babe0f

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

Service Bulletin 
Fokker 70/100 
 
Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Revision 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 
Page 18 19 20 21 22 23 24 25 26 27 28 29      
Revision 1 1 1 1 1 1 1 1 1 1 1 1      
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 1 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
 
ELECTRICAL POWER 
 
 
General - A one-time Inspection and Adjustment of the Torque Values on the Circuit 
Breakers, Contactors and Terminal Blocks in the EPC and Battery Relay Panel. 
 
 
 
1. Planning Information  
A. Effectivity 
(1) F28 Mark 0070/0100 aircraft serial numbers: 
11244 thru 11585 
(2) Production version of this modification: Not applicable. 
B. Concurrent Requirements 
(1) Before you do this SB, you must do, if applicable: 
- SBF100-24-032 - ELECTRICAL POWER – DC Bus Transfer – The Modification to 
the DC Bus Transfer System. 
(2) Before you do this SB, you must do, if applicable: 
- SBF100-24-041 - ELECTRICAL POWER – AC Bus Transfer – Introduction of Self-
Locking Nuts on the Terminal Posts of Electrical Power Contactor pn SG02206. 
 
NOTE: Disregard the associated Manual  Change Notification MCNM F100-120. 
C. Reason 
(1) Fokker Services received reports about loose nuts of contactors in the Electrical 
Power Center (EPC). In some cases this led to damaged (burned) contactors. 
(2) In the past SBF100-24-011 (Alert SB) was issued to inspect and adjust several 
torque values of bus bars and contactors in the EPC and Battery Relay Panel.

### Page 2

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 2 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
(3) In the POST SBF100-24-A011 configuration, still loose nuts are found on contactors 
in the EPC, which cause damaged and/or burned contactors. For that reason, a one-
time inspection on torque values on nuts for electrical connections in the EPC and 
Battery Relay Panel must be done. Furthermore, new lock washers and certain new 
self locking nuts must be installed. 
 
Reason for Revision: 
This revision is made to: 
- Incorporate SBCN /01 and SBCN /02 
- Add Terminal Block TB4906A to table 6 on page 16. 
D. Description  
(1) This Service Bulletin is divided into two parts as follows: 
Part 1: Inspection and Adjustment of the Torque Values for the Fokker 100 Aircraft. 
 
This Part tells you how to: 
- Inspect and adjust the torque values of: 
 - Circuit breakers 
- Fuse holder 
- Relays and contactors 
- Terminal blocks 
- Replace installed lock washers and certain self locking nuts. 
- Use the torque inspection lacquer to seal the nuts. 
Part 2: Inspection and Adjustment of the Torque Values for the Fokker 70 Aircraft. 
 
This Part tells you how to: 
- Inspect and adjust the torque values of: 
 - Circuit breakers 
- Fuse holder 
- Relays and contactors. 
- Terminal blocks  
- Replace installed lock washers and certain self locking nuts. 
- Use the torque inspection lacquer to seal the nuts. 
Part 3: Completion and Testing for the Fokker 100 and Fokker 70 Aircraft. 
 
This Part tells you how to: 
- Complete the job. 
- Perform the applicable testing.

### Page 3

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 3 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
E. Compliance 
(1) Recommended. 
 
Fokker Services recommend the accomplishment of this service bulletin within 2 
years after the original issue date of this bulletin. 
 
NOTE: It is expected that EASA will issue an Airworthiness Directive (AD) with 
respect to this subject with the same compliance terms. Refer to the EASA 
web site for the publication of a Proposed Airworthiness Directive for 
comments. 
F. Approval 
(1) The technical content of this document is approved under the authority of DOA nr. 
EASA.21J.059.

### Page 4

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 4 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
G. Manpower 
(1) Approximately 9,0 man-hours are necessary to do Part 1  and Part 3 of this SB on 
one Fokker 100 aircraft applicable to serial numbers 11244 thru 11461. 
 
This table of manpower will help you to schedule and do this Service Bulletin: 
 
Instructions Men Man-hours Elapsed time 
(hours) 
Removal 1 1 1 
Modification 
Inspection 2 4 3 
Installation 
Testing 
2 4 2 
Total  9,0 6,0 
 
(2) Approximately 16,0 man-hours are necessary to do: 
Part 1 and Part 3 of this SB on one Fokker 100 aircraft applicable to serial numbers 
11462 thru 11507, 11509, 11511 thru 11520, 11522, 11523 and 11527 or  
Part 2 and Part 3 of this SB on one Fokker 70 aircraft. 
 
This table of manpower will help you to schedule and do this Service Bulletin: 
 
Instructions Men Man-hours Elapsed time 
(hours) 
Removal 2 4 2 
Modification 
Inspection 2 4 3 
Installation 
Testing 
2 8 4 
Total  16,0 9,0 
 
NOTE: This estimate does not include the time necessary for the paint to dry 
and/or the sealant to cure. 
(3) The estimated hours are for direct labor done by experienced personnel. They are 
calculated based on the conditions given in SBF100-00-001 (Service Bulletin 
Introduction, section 2.C., "Manpower"). 
H. Weight and Balance 
(1) Weight change: None 
Index change:  None. 
I. Electrical Load Data 
(1) Not affected.

### Page 5

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 5 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
J. Software Accomplishment Instructions 
(1) Not applicable. 
K. References 
(1) Fokker 70/100 Aircraft Maintenance Manual (AMM) 
Fokker 70/100 Service Bulletin (SB): 
 - SBF100-24-A011 
 - SBF100-24-032 
 - SBF100-24-041 
Fokker internal reference(s): 
 - ECR 15713. 
L. Publications Affected 
(1) This SB affects the publications listed below: 
(a) Maintenance Documentation  
 
- Fokker 70/100 Aircraft Maintenance Manual (AMM) - chapter 20-13 
  - chapter 24-22 
  - chapter 24-33 
- Fokker 70/100 Wiring Manual (WM) - chapter 20-13 
- Fokker 70/100 Illustrated Parts Catalog (IPC) - chapter 24-22 
  - chapter 25-72. 
 
NOTE: See attached Manual Change Notification MCNM F100-141. 
(b) Maintenance Programs  
 
Not affected.

### Page 6

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 6 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
(c) Special Instructions for Continued Airworthiness (ICA)  
 
The effect of this Service Bulletin on the special ICA is as follows: 
 
  YES NO 
- Electrical Wiring Interconnection System (EWIS) - X 
- Fuel Tank Safety (FTS) - X 
- Damage Tolerance of Fatigue Critical Structure - X 
NOTE: If “YES”, when not already incorporated, the changed ICA will be 
incorporated in the MRB document within one calendar year from the 
date of issue of this Service Bulletin. Until then, no actions are required. 
(d) Operational Documentation  
 
Not affected. 
(2) Report to Fokker Services that this SB has been carried out in the applicable aircraft. 
(3) For incorporation of this Service Bulletin in your documentation refer to 
SBF100-00-001 (Service Bulletin Introduction, section 4 "Incorporation of Service 
Bulletins in Documentation of Fokker Services"). 
NOTE: Accomplishment of this SB is only complete with incorporation of the manual 
change(s) per the ref. MCNM/MCNO, Temporary Revision or General Revision. 
M. Interchangeability or Intermixability of Parts 
(1) Not applicable.

### Page 7

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 7 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
2. Material Information  
A. Material – Price and Availability 
(1) You can order the necessary parts as mod kits SB10024043-XU-A,  
SB10024043-XU-B or SB10024043-XU-C. 
(2) You can contact your Fokker Services Account Manager for the price and lead-time of 
this mod kit. 
B. Material Required 
(1) These parts, which are necessary to complete this Service Bulletin on 1 aircraft, are 
not part of the mod kit. 
 
New Part Number Qty  Keyword  Info  Old Part Number  Instructions/  
 * 1 *2    Disposition  
F900 AR* AR* Torque 
inspection 
lacquer 
Fk05-084** 
Color: orange 
- Local source 
N157187-6 9 - Nut, self-
locking 
See remark 1 N157187-6 Local source/ 
Discard 
N157187-6 2 - Nut, self-
locking 
See remark 2 N157187-6 Local source/ 
Discard 
N193920-5 - 2 Lock washer See remark 3  N193920-5 Local source/ 
Discard 
       
NOTES: *  Use as much as necessary 
 ** Refer to the CML for material numbers. 
 * 1 Applicable to the Fokker 100 Aircraft,  
 * 2 Applicable to Fokker 70 Aircraft. 
 
 
REMARKS: 1.  Nine self-locking nuts PN N157187-6 are required for GLC 1, BTC 1, 
  APC, GLC 2, BTC 2 and/or EPC if in the POST SBF100-24-037 
  configuration. 
 2. Two self-locking nuts PN N157187-6 are required if PN SA02217 is 
  installed instead of the original installed PN SA02202 which require 
  lock washers PN193920-5. 
 3. Two lock washers PN N193920-5 are required if PN SA02202 is 
  installed instead of the original installed PN SA02217 which require 
  self-locking nuts PN157187-6.

### Page 8

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 8 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
(2) These mod kit parts are necessary to do this Service Bulletin on 1 aircraft. 
 
New Part 
Number 
Qty Keyword  Info  Old Part Number  Instructions/
Disposition 
 A  B  C      
MS35338-41 44* 44* 63 Lock washer - MS35338-41 Discard 
MS35338-43 46* 46* 73 Lock washer - MS35338-43 Discard 
MS35338-44 4 4 4 Lock washer - MS35338-44 Discard 
MS35338-98 12 12 - Lock washer - MS35338-98 Discard 
MS35338-100 27 27 - Lock washer - MS35338-100 Discard 
MS35338-137 4 4 4 Lock washer - MS35338-137 Discard 
N157187-6 - - 62 Nut, self-locking - N157187-6 Discard 
N193920-5 8 8 - Lock washer - N193920-5 Discard 
5964800 8* 4* 2 Lock washer - 5964800 Discard 
5995000 8* 4* 2 Lock washer - 5995000 Discard 
79800754002 4 4 4 Nut and washer, 
captive 
- 79800754002 Discard 
        
 
NOTES: * Maximum required quantity is given. 
(3) Applicability of mod kits: 
Qty A (mod kit SB10024043-XU-A) is applicable to do this Service Bulletin on one 
aircraft sn 11244 thru 11461. 
Qty B (mod kit SB10024043-XU-B) is applicable to do this Service Bulletin on one 
aircraft sn 11462 thru 11507, 11509, 11511 thru 11520, 11522, 11523 and 11527. 
Qty C (mod kit SB10024043-XU-C) is applicable to do this Service Bulletin on one 
aircraft sn 11521, 11528, 11529, 11532, 11536 thru 11541, 11543, 11545, 11547, 
11549, 11551, 11553 thru 11583 and 11585. 
C. Tooling – Price and Availability 
(1) Not applicable. 
D. Drawings Required 
(1) Not applicable.

### Page 9

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 9 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
3. Accomplishment Instructions  
 
General 
- Obey the warnings, cautions and safety inst ructions in the procedures we refer you to. 
- In case of conflict between the torque values mentioned in AMM task 20-12-00-910-822-A 
 and D and/or 20-13-00-400-812-A and this service bulletin the latter shall govern. 
- When for an equipment number two different part numbers are given, apply the torque 
 value for the installed part number. 
- Inspect and adjust one contact at a time. 
- Use a suitable calibrated torque wrench to apply the correct torque. 
- When the required material column shows none, inspect and torque the nut or screw as 
follows: 
• Inspect the contact for corrosion, erosion, decontamination, etc. 
• If torque inspection lacquer is present, clean the thread of the stud. 
• Loosen the screw or nut two turns. 
• Torque the nut to the value given in the Table. 
• Apply the torque inspection lacquer. 
 
NOTE:  For the heatsinks only a visual inspection is required as indicated in the Table. 
 
- When the required material column shows required materials, inspect and torque the nut as 
follows: 
• Inspect the contact for corrosion, erosion, decontamination, etc. 
•  Remove and discard the lock washer or self-locking nut. 
•  If torque inspection lacquer is present, clean the thread of the stud and the normal nut  
if the nut is re-used. 
•  Use a new lock washer or new self-locking nut as given in the Table. 
• Torque the nut to the value given in the Table. 
•  Apply the torque inspection lacquer. 
 
WARNING: PUT UP THE APPLICABLE WARNING SIGNS TO PREVENT INJURY TO 
PERSONS.

### Page 10

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 10 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
Part 1: Inspection and Adjustment of the Torque Values for the Fokker 100 Aircraft. 
A. Remove all electrical power (Refer to the AMM, chapter 24-00-00-860-912A). 
B. Instructions for the Battery relay panel and terminal block in the forward cargo 
compartment, zone 152. 
(1) Remove access panel just before battery relay panel and open the battery relay 
panel. 
Refer to figure 1A or 1B depending on the part number of relays K 0563A and K 0564A. 
(2) Find the equipment mentioned in Table 1 and check if either the lock washer, flat 
washer and nut, or the locking nut and flat washer are installed and re-torque the nuts 
to the required torque value, refer to General for detailed information. Apply torque 
inspection lacquer. Use: 
- AR torque inspection lacquer pn F900. 
 
Equipment Description Part number Torque values Required material 
CB0597A GND HDLG Bus Supply Bat Bus 1 3TC14-30 1.5 Nm  (13.3 in.lb) Lock washer: 2x pn MS35338-137 
CB0598A GND HDLG Bus Supply Bat Bus 2 3TC14-30 1.5 Nm  (13.3 in.lb) Lock washer: 2x pn MS35338-137 
CB0557A 
DC EMER Bus Supply 
Bat Bus 1 160-012-50 3.6 Nm  (32.0 in.lb) None 
CB0558A DC EMER Bus Supply Bat Bus 2 160-012-50 3.6 Nm  (32.0 in.lb) None 
CB0580A Pwr Supply Bat Bus 1 160-012-50 3.6 Nm  (32.0 in.lb) None  
CB0592A Pwr Supply Bat Bus 2 160-012-50 3.6 Nm  (32.0 in.lb) None  
CB0748A APU Eng Start Motor 170-001-160 3.6 Nm  (32.0 in.lb) None  
K 0563A Bat 1 Isolate Contactor 
M520U5N 
Main:   1.7 Nm (15 in.lb) 
Aux/coil  0.4 Nm (3,3 in.lb) 
Lock washer: 
2x pn 5964800 
2x pn 5995000 
M600-9336 
Main:   2.7 Nm (24 in.lb) 
Aux/coil: 0.8 Nm (7.5 in.lb) 
Lock washer: 
2x pn MS35338-43 
2x pn MS35338-41 
K 0564A Bat 2 Isolate Contactor 
M520U5N 
Main:   1.7 Nm (15 in.lb) 
Aux/coil  0.4 Nm (3.3 in.lb) 
Lock washer: 
2x pn 5964800 
2x pn 5995000 
M600-9336 
Main:   2.7 Nm (24 in.lb) 
Aux/coil: 0.8 Nm (7.5 in.lb) 
Lock washer: 
2x pn MS35338-43 
2x pn MS35338-41 
K 0711A APU Start Contactor Bat 1 SA02202 6 – 6.5 Nm  (53.1-57.5 in.lb) Lock washer: 2x pn N193920-5 SA02217 6 – 6.5 Nm  (53.1-57.5 in.lb) Nut, self-locking: 2x pn N157187-6 
K 0712A APU Start Contactor Bat 2 SA02202 6 – 6.5 Nm  (53.1-57.5 in.lb) Lock washer: 2x pn N193920-5 SA02217 6 – 6.5 Nm  (53.1-57.5 in.lb) Nut, self-locking: 2x pn N157187-6

### Page 11

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
Equipment Description Part number Torque values Required material 
K 0713A APU Start Contactor Ext Power SA02202 6 – 6.5 Nm  (53.1-57.5 in.lb) Lock washer: 2x pn N193920-5 SA02217 6 – 6.5 Nm  (53.1-57.5 in.lb) Nut, self-locking: 2x pn N157187-6 
 
For figure 1A: 
Bolt to connect APU 
start cable AHC0008-
B7 to connection strip 
from CB0748A 
 
For figure 1B: 
NOT APPLICABLE 
 
 
 
NAS1304-7 
 
 
 
6 – 6.5 Nm (53-57.5 in.lb) 
 
 
 
None 
TB2483A* 
Terminal block aircraft 
interface battery relay 
panel. 
LRS10-009 
.250 stud: 
      6.7 Nm (60.0 in.lb) None 
.375 stud: 
     13.5 Nm (119.5 in.lb) None 
 
NOTE: * This terminal block is not shown in figure 1A or 1B and is located just before the battery 
relay panel. 
Battery Relay Panel Fokker 100 
Table 1 
(3) Close the battery relay panel and install the access panel.

### Page 12

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 12 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
C. Instructions for the Emergency power box, zone 246 
(1) Remove access panel 246AZ to get access to the EPC. 
 
Refer to figure 2. 
(2) Find the components mentioned in Table 2 and check if either the lock washer, flat 
washer and nut, or the locking nut and flat washer are installed and re-torque the nuts 
to the required torque value, refer to General for detailed information. Apply torque 
inspection lacquer. Use: 
- AR torque inspection lacquer pn F900. 
 
Equipment Description Part number Torque values Required material 
K 5813A BPC HA4N120 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 6x pn MS35338-43 4x pn MS35338-41 
K 1552A EIC 
M520U5N Main:   1.7 Nm (15 in.lb) Aux/coil: 0.4 Nm (3.3 in.lb) Lock washer: 2x pn 5964800 2x pn 5995000 
M600-9336 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 2x pn MS35338-43 2x pn MS35338-41 
 
T 1554A T 2 AE5902MK1 0.4 Nm  (3.5 in.lb) 
Nut and washer, 
captive: 
4x pn 79800754002 
 
 Emergency Power Box Fokker 100 
 Table 2 
(3) Install access panel 246AZ removed in step (1). 
 
 
D. Instructions for the Electrical Power Center (EPC), zone 245 
(1) Remove access panels 245AZ and 245BZ to get access to the EPC. 
Refer to figure 3. 
(2) Find the equipment mentioned in Table 3 (upper part of EPC) and check if either the 
lock washer, flat washer and nut, or the locking nut and flat washer are installed and 
re-torque the nuts to the required torque value. Apply torque inspection lacquer, refer 
to General for detailed information. Use: 
- AR torque inspection lacquer pn F900.

### Page 13

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 13 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
Equipment Description Part number Torque value Required material 
K 0568A DC EBPC ZC-A2N Main:  6.4 Nm (56.4 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 4x pn MS35338-44 8x pn MS35338-41 
TB0609A Heatsink DC Ground Handling D43255-4xx or A47010-4xx Visual inspect all contacts (self locking nuts tightened) None 
 
 Upper Part of EPC Fokker 100 
 Table 3 
Refer to figure 4. 
(3) Find the equipment mentioned in Table 4 (middle part of EPC) and check if either the 
lock washer, flat washer and nut, or the locking nut and flat washer are installed and 
re-torque the nuts to the required torque value, refer to General for detailed 
information. Apply torque inspection lacquer. Use: 
- AR torque inspection lacquer pn F900. 
 
Equipment Description Part number Torque value Required material 
K 0308A GLC 1 
SG02206 
NOTE: Perform SBF100-24-
041 None 
SG02206FA- 
POST SBF100-24-041: Apply 
only torque inspection lacquer None 
SG02213 6 - 6,5 Nm (53.1 - 57,5 in.lb) Nut, self-locking: 9x pn N157187-6 
K 0525A BTC 1 
SG02206 
NOTE: Perform SBF100-24-
041 None 
SG02206FA- 
POST SBF100-24-041: Apply 
only torque inspection lacquer None 
SG02213 6 – 6.5 Nm  (53.1 - 57.5 in.lb) Nut, self-locking: 9x pn N157187-6 
K 0527A APC 
SG02206 
NOTE: Perform SBF100-24-
041 None 
SG02206FA- 
POST SBF100-24-041: Apply 
only torque inspection lacquer None 
SG02213 6 – 6.5 Nm  (53.1 - 57.5 in.lb) Nut, self-locking: 9x pn N157187-6 
K 0571A DC BTC 
SA02202 6 – 6.5 Nm  (53.1 - 57.5 in.lb) Lock washer: 2x pn N193920-5 
SA02217 6 – 6.5 Nm  (53.1 - 57.5 in.lb) Nut, self-locking: 2x pn N157187-6 
X 0572B Fuse holder 4164 7 – 7.5 Nm  (62.0 – 66.0 in.lb) None 
TB0084A Heatsink D43255-4xx or A47010-4xx Visual inspect all contacts (self locking nuts tightened) None 
TB0092A Heatsink D43255-4xx or A47010-4xx  Visual inspect all contacts (self locking nuts tightened) None 
K 0605A GHBC 1 M520U5N Main:   1.7 Nm (15 in.lb) Aux/coil: 0.4 Nm (3.3 in.lb) Lock washer: 2x pn 5964800 2x pn 5995000

### Page 14

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 14 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
Equipment Description Part number Torque value Required material 
K 0607A GHBC 2 M600-9336 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 2x pn MS35338-43 4x pn MS35338-41 
K 1270A DC EPR M600-9336 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 4x pn MS35338-43 5x pn MS35338-41 
K 1355A GBPC 1 
9124-8063 
9124-9283 
9124-1ZC7D3-
002 
Main:   2.7 Nm (24 in.lb) 
Aux/coil: 0.8 Nm (7.5 in.lb) 
Lock washer: 
6x pn MS35338-43 
2x pn MS35338-41 
K 0529A GPTC DHR18-1 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 9x pn MS35338-100 4x pn MS35338-98 
K 0530A EBTC DHR18-1 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 9x pn MS35338-100 4x pn MS35338-98 
K 0531A APTC DHR18-1 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 9x pn MS35338-100 4x pn MS35338-98 
K 0567A DC EBTC M600-9336 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 4x pn MS35338-43 5x pn MS35338-41 
TB1772A Terminal block LRS10-005 13.5 Nm (119.5 in.lb) None 
TB1773A Terminal block LRS10-005 13.5 Nm (119.5 in.lb) None 
TB1774A Terminal block LRS10-005 13.5 Nm (119.5 in.lb) None  
TB1797A Terminal block LRS10-005 13.5 Nm (119.5 in.lb) None  
TB1798A Terminal block LRS10-005 13.5 Nm (119.5 in.lb) None  
TB1799A Terminal block LRS10-005 13.5 Nm (119.5 in.lb) None  
TB1919A Terminal block LRS10-004 13.5 Nm (119.5 in.lb) None  
TB1920A Terminal block LRS10-004 13.5 Nm (119.5 in.lb) None  
TB1921A Terminal block LRS10-004 13.5 Nm (119.5 in.lb) None  
TB1950A* Terminal block LRS101-01 3.1 Nm (27.4 in.lb) None  
TB1950B* Terminal block LRS101-01 3.1 Nm (27.4 in.lb) None  
 
NOTE: *These terminal blocks are located behind circuit breaker panel 2. 
 
 Middle Part of EPC Fokker 100 
 Table 4

### Page 15

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 15 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
Refer to figure 5. 
(4) Find the components mentioned in Table 5 (lower part of EPC) and check if either the 
lock washer, flat washer and nut, or the locking nut and flat washer are installed and 
re-torque the nuts to the required torque value, refer to General for detailed 
information. Apply torque inspection lacquer. Use: 
- AR torque inspection lacquer pn F900. 
 
Equipment Description Part number Torque values Required material 
K 0318A GLC 2 
SG02206 NOTE : Perform SBF100-24-041 None
SG02206FA- POST SBF100-24-041: Apply only torque inspection lacquer None 
SG02213 6 - 6,5 Nm (53.1 - 57,5 in.lb) Nut, self-locking: 9x pn N157187-6 
K 0526A BTC 2 
SG02206 NOTE : Perform SBF100-24-041 None
SG02206FA- POST SBF100-24-041: Apply only torque inspection lacquer None 
SG02213 6 - 6,5 Nm (53.1 - 57,5 in.lb) Nut, self-locking: 9x pn N157187-6 
K 0528A EPC 
SG02206 NOTE : Perform SBF100-24-041 None
SG02206FA- POST SBF100-24-041: Apply only torque inspection lacquer None 
SG02213 6 - 6,5 Nm (53.1 - 57,5 in.lb) Nut, self-locking: 9x pn N157187-6 
K 0541A GSBC 2 
9124-8063 
9124-9283 
9124-1ZC7D3-
002 
Main:   2.7 Nm (24 in.lb) 
Aux/coil: 0.8 Nm (7.5 in.lb) 
Lock washer: 
6x pn MS35338-43 
4x pn MS35338-41 
K 0556A GSBC 1 
9124-8063 
9124-9283 
9124-1ZC7D3-
002 
Main:   2.7 Nm (24 in.lb) 
Aux/coil: 0.8 Nm (7.5 in.lb) 
Lock washer: 
6x pn MS35338-43 
4x pn MS35338-41 
K 1356A GBPC 2 
9124-8063 
9124-9283 
9124-1ZC7D3-
002 
Main:   2.7 Nm (24 in.lb) 
Aux/coil: 0.8 Nm (7.5 in.lb) 
Lock washer: 
6x pn MS35338-43 
2x pn MS35338-41 
TB1930A Terminal block LRS10-005 13.5 Nm (119.5 in.lb) None
TB1931A Terminal block LRS10-005 13.5 Nm (119.5 in.lb) None
TB1932A Terminal block LRS10-005 13.5 Nm (119.5 in.lb) None
TB1916A Terminal block LRS10-004 13.5 Nm (119.5 in.lb) None
TB1917A Terminal block LRS10-004 13.5 Nm (119.5 in.lb) None
TB1918A Terminal block LRS10-004 13.5 Nm (119.5 in.lb) None
TB1794A Terminal block LRS10-005 13.5 Nm (119.5 in.lb) None
TB1795A Terminal block LRS10-005 13.5 Nm (119.5 in.lb) None
TB1796A Terminal block LRS10-005 13.5 Nm (119.5 in.lb) None
 
 Lower Part of EPC Fokker 100 
 Table 5

### Page 16

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 16 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
Step E is only applicable for aircraft serial numbers: 
 11462 thru 11507, 11509, 11511 thru 11520, 11522, 11523 and 11527. 
E. Instructions for the Terminal Blocks on Rear Side of the EPC. 
(1) Remove Galley 1 (Refer to the AMM, chapter 25-31-00). 
(2) Find the components mentioned in Table 6 on the rear side of EPC and check if the 
locking nut and flat washer are installed and re-torque the nuts to the required torque 
value, refer to General for detailed information. Apply torque inspection lacquer. Use: 
- AR torque inspection lacquer pn F900. 
 
Equipment Description Part number Torque value Required material
TB4906A Terminal block LRS10-011 3.1 Nm (27.4 in.lb) None  
TB4907A Terminal block LRS10-012 3.1 Nm (27.4 in.lb) None  
TB4903A Terminal block LRS10-013 13.5 Nm (119.5 in.lb) None  
TB4902A Terminal block LRS10-014 .250 stud:   6.7 Nm   (60.0 in.lb) .375 stud: 13.5 Nm (119.5 in.lb) None 
TB4904A Terminal block LRS10-015 .250 stud:   6.7 Nm   (60.0 in.lb) .375 stud: 13.5 Nm (119.5 in.lb) None 
TB4908A Terminal block LRS10-014 .250 stud:   6.7 Nm   (60.0 in.lb) .375 stud: 13.5 Nm (119.5 in.lb) None 
 
 Rear Side of EPC Fokker 100 
 Table 6 
(3) Install Galley 1 (Refer to the AMM, chapter 25-31-00).

### Page 17

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 17 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
Part 2: Inspection and Adjustment of the Torque Values for the Fokker 70 Aircraft. 
 
A. Remove all electrical power (Refer to the AMM, chapter 24-00-00-860-912A). 
B. Instructions for the Battery relay panel and terminal block in the forward cargo 
compartment, zone 152. 
(1) Remove access panel just before battery relay panel and open the battery relay 
panel. 
Refer to figure 6. 
(2) Find the equipment mentioned in Table 7 and check if either the lock washer, flat 
washer and nut, or the locking nut and flat washer are installed and re-torque the nuts 
to the required torque value, refer to General for detailed information. Apply torque 
inspection lacquer. Use: 
- AR torque inspection lacquer pn F900. 
 
Equipment Description Part number Torque values Required material 
CB0597A GND HDLG Bus Supply Bat Bus 1 3TC14-30 1.5 Nm  (13.3 in.lb) Lock washer: 2x pn MS35338-137 
CB0598A GND HDLG Bus Supply Bat Bus 2 3TC14-30 1.5 Nm  (13.3 in.lb) Lock washer: 2x pn MS35338-137 
CB0557A DC EMER Bus Supply Bat Bus 1 160-012-50 3.6 Nm  (32.0 in.lb) None 
CB0558A DC EMER Bus Supply Bat Bus 2 160-012-50 3.6 Nm  (32.0 in.lb) None 
CB0580A Power Supply Bat Bus 1 160-012-50 3.6 Nm  (32.0 in.lb) None 
CB0592A Power Supply Bat Bus 2 160-012-50 3.6 Nm  (32.0 in.lb) None 
CB0748A APU Engine Start Motor 170-001-160 3.6 Nm  (32.0 in.lb) None 
K 0563A Bat 1 Isolate Contactor M600-9336 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 2x pn MS35338-43 5x pn MS35338-41 
K 0564A Bat 2 Isolate Contactor M600-9336 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 2x pn MS35338-43 5x pn MS35338-41 
K 0711A APU Start Contactor Bat 1 SA02202 6 - 6.5 Nm (53.1-57.5 in.lb) Lock washer: 2x pn N193920-5 SA02217 6 - 6.5 Nm (53.1-57.5 in.lb) Nut, self-locking: 2x pn N157187-6 
K 0712A APU Start Contactor Bat 2 SA02202 6 - 6.5 Nm (53.1-57.5 in.lb) Lock washer: 2x pn N193920-5 SA02217 6 - 6.5 Nm (53.1-57.5 in.lb) Nut, self-locking: 2x pn N157187-6 
K 0713A APU Start Contactor Ext Power SA02202 6 - 6.5 Nm (53.1-57.5 in.lb) Lock washer: 2x pn N193920-5 SA02217 6 - 6.5 Nm (53.1-57.5 in.lb) Nut, self-locking: 2x pn N157187-6

### Page 18

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 18 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
Equipment Description Part number Torque values Required material 
TB2483A* 
Terminal block aircraft 
interface battery relay 
panel. (Located behind 
the ceiling just before 
the battery relay panel) 
LRS10-009 
.250 stud: 
       6.7 Nm (60.0 in.lb) None 
.375 stud: 
    13.5 Nm (119.5 in.lb) None 
 
NOTE: * This terminal block is not shown in figure 6 and is located just before the battery relay 
panel. 
 
 Battery Relay Panel Fokker 70 
 Table 7 
 
C. Instructions for the Emergency power box, zone 246 
(1) Remove access panel 246AZ to get access to the EPC. 
 
Refer to figure 7. 
(2) Find the equipment mentioned in Table 8 and check if either the lock washer, flat 
washer and nut, or the locking nut and flat washer are installed and re-torque the nuts 
to the required torque value, refer to General for detailed information. Apply torque 
inspection lacquer:  
- AR torque inspection lacquer pn F900. 
 
Equipment Description Part number Torque value Required material 
K 5813A BPC HA4N120 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 6x pn MS35338-43 4x pn MS35338-41 
T 1554A T 2 AE5902MK1 0.4 Nm  (3.5 in.lb) 
Nut and washer, 
captive: 
4x pn 79800754002 
 
 Emergency Power Box Fokker 70 
 Table 8 
 
D. Instructions for the Electrical Power Center (EPC), zone 245 
(1) Remove access panels 245AZ and 245BZ to get access to the EPC. 
Refer to figure 8. 
(2) Find the equipment mentioned in Table 9 (upper part of EPC) and check if either the 
lock washer, flat washer and nut, or the locking nut and flat washer are installed and 
re-torque the nuts to the required torque value, refer to General for detailed 
information. Apply torque inspection lacquer. Use: 
- AR torque inspection lacquer pn F900.

### Page 19

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 19 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
Equipment Description Part number Torque values Required material 
K 0568A DC EBPC ZC-A2N Main:   6.4 Nm (56.4 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 4x pn MS35338-44 8x pn MS35338-41 
TB0609A Heatsink DC Ground Handling A47010-4xx Visual inspect all contacts(self locking nuts tightened) None 
 
 Upper Part of EPC Fokker 70 
 Table 9 
Refer to figure 9. 
(3) Find the equipment mentioned in Table 10 (middle part of EPC) and check if either 
the lock washer, flat washer and nut, or the locking nut and flat washer are installed 
and re-torque the nuts to the required torque value, refer to General for detailed 
information. Apply torque inspection lacquer. Use: 
- AR torque inspection lacquer pn F900. 
 
Equipment Description Part number Torque values Required material 
K 1335A GBPC 1 
9124-8063 
9124-9283 
9124-1ZC7D3-
002 
Main:   2.7 Nm (24 in.lb) 
Aux/coil: 0.8 Nm (7.5 in.lb) 
Lock washer: 
6x pn MS35338-43 
2x pn MS35338-41 
K 0308A GLC 1 SG02217 6 - 6.5 Nm (53.1 - 57.5 in.lb) Nut, self-locking: 9x pn N157187-6 
- Feeders to K 0308A NAS6704U2 6.7 Nm (60.0 in.lb) None 
K 0525A BTC 1 SG02217 6 - 6.5 Nm   (53.1 - 57.5 in.lb) Nut, self-locking: 9x pn N157187-6 
K 0571A DC BTC 
SA02202 6 - 6.5 Nm   (53.1 - 57.5 in.lb) Lock washer: 2x pn N193920-5 
SA02217 6 - 6.5 Nm   (53.1 - 57.5 in.lb) Nut, self-locking: 2x pn N157187-6 
X 0572B Fuse holder 4164 7 - 7.5 Nm  (62.0 – 66.0 in.lb) None 
TB0084A Heatsink A42710-xxx  Visual inspect all contacts (self locking nuts tightened) None 
K0567A DC EBTC M600-9336 Main:  2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 4x pn MS35338-43 5x pn MS35338-41 
K 0529A GPTC HCA1F029 Main:  2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 9x pn MS35338-43 4x pn MS35338-41 
K 0530A EBTC HCA1F029 Main:  2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 9x pn MS35338-43 4x pn MS35338-41 
TB1950A* Terminal block LRS101-01 3.1 Nm (27.4 in.lb) None
TB1950B* Terminal block LRS101-01 3.1 Nm (27.4 in.lb) None
 
NOTE: *These terminal blocks are located behind circuit breaker panel 2. 
 
 Middle Part of EPC Fokker 70 
 Table 10

### Page 20

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 20 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
Refer to figure 10. 
(4) Find the components mentioned in Table 11 (lower part of EPC) and check if either 
the lock washer, flat washer and nut, or the locking nut and flat washer are installed 
and re-torque the nuts to the required torque value, refer to General for detailed 
information. Apply torque inspection lacquer. Use: 
- AR torque inspection lacquer pn F900. 
 
Equipment Description Part number Torque values Required material 
K 0527A APC SG02217 6 - 6.5 Nm (53.1 - 57.5 in.lb) Nut, self-locking: 9x pn N157187-6 
- Feeders to K 0527A NAS6704U2 6.7 Nm (60.0 in.lb) None 
K 0528A EPC SG02217 6 - 6.5 Nm (53.1 - 57.5 in.lb) Nut, self-locking: 9x pn N157187-6 
- Feeders to K 0528A NAS6704U2 6.7 Nm (60.0 in.lb) None 
K 0526A BTC 2 SG02217 6 - 6.5 Nm (53.1 - 57.5 in.lb) Nut, self-locking: 9x pn N157187-6 
K 0318A GLC 2 SG02217 6 - 6.5 Nm (53.1 - 57.5 in.lb) Nut, self-locking: 9x pn N157187-6 
- Feeders to K 0318A NAS6704U2 6.7 Nm (60.0 in.lb) None 
K 0556A GSBC 1 
9124-8063 
9124-9283 
9124-1ZC7D3-
002 
Main:   2.7 Nm (24 in.lb) 
Aux/coil: 0.8 Nm (7.5 in.lb) 
Lock washer: 
6x pn MS35338-43 
4x pn MS35338-41 
K 0541A GSBC 2 
9124-8063 
9124-9283 
9124-1ZC7D3-
002 
Main:   2.7 Nm (24 in.lb) 
Aux/coil: 0.8 Nm (7.5 in.lb) 
Lock washer: 
6x pn MS35338-43 
4x pn MS35338-41 
K 1356A GBPC 2 
9124-8063 
9124-9283 
9124-1ZC7D3-
002 
Main:   2.7 Nm (24 in.lb) 
Aux/coil: 0.8 Nm (7.5 in.lb) 
Lock washer: 
6x pn MS35338-43 
4x pn MS35338-41 
K 0531A APTC HCA1F029 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 9x pn MS35338-43 4x pn MS35338-41 
 
K 0605A GHBC 1 M520U5N Main:   1.7 Nm (15 in.lb) Aux/coil: 0.4 Nm (3.3 in.lb) Lock washer: 2x pn 5964800 2x pn 5995000 
K 1270A DC EPR M600-9336 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 4x pn MS35338-43 5x pn MS35338-41 
K 0607A GHBC 2 M600-9336 Main:   2.7 Nm (24 in.lb) Aux/coil: 0.8 Nm (7.5 in.lb) Lock washer: 4x pn MS35338-43 5x pn MS35338-41 
TB0092A Heatsink A47010-4xx Visual inspect all contacts (self locking nuts tightened) None 
 
 Lower Part of EPC Fokker 70 
 Table 11

### Page 21

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 21 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
E. Instructions for the Terminal Blocks on Rear Side of the EPC. 
(1) Remove Galley 1 (Refer to the AMM, chapter 25-31-00). 
(2) Find the components mentioned in Table 12 (rear side of EPC) and check if the 
locking nut and flat washer are installed and re-torque the nuts to the required torque 
value, refer to General for detailed information. Apply torque inspection lacquer. Use: 
- AR torque inspection lacquer pn F900. 
 
Equipment Description Part number Torque values Required material 
TB4906A Terminal block LRS10-011 3.1 Nm   (27.4 in.lb) None
TB4907A Terminal block LRS10-011 3.1 Nm   (27.4 in.lb) None
TB4903A Terminal block LRS10-018 13.5 Nm (119.5 in.lb) None
TB5232A Terminal block LRS10-020 6.7 Nm  (60.0 in.lb) None
TB4902A Terminal block LRS10-019 .250 stud:   6.7 Nm  (60.0 in.lb) .375 stud: 13.5 Nm (119.5 in.lb) None 
TB4908A Terminal block LRS10-018 13.5 Nm (119.5 in.lb) None
TB4904A Terminal block LRS10-019 .250 stud:   6.7 Nm  (60.0 in.lb) .375 stud: 13.5 Nm (119.5 in.lb) None 
TB5233A Terminal block LRS10-020 6.7 Nm  (60.0 in.lb) None
 
 Rear Side of EPC Fokker 70 
 Table 12 
 
(3) Install Galley 1 (Refer to the AMM, chapter 25-31-00).

### Page 22

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 22 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
Part 3: Completion and Testing for the Fokker 100 and Fokker 70 aircraft. 
A. Remove the tools, materials and equipment from the work areas. Make sure the work 
areas are clean. 
B. Install access panels 246AZ, 245AZ and 245BZ. 
C. Connect the batteries (Refer to the AMM, chapter 24-00-00-860-922). 
D. Do the following tests and checks: 
(1) Operational Check of the Battery connection to the DC Emergency Bus. (Refer to the 
AMM, chapter 24-32-00-710-835). 
(2) Operational Check of the DC Essential and Emergency buses. (Refer to the AMM, 
chapter 24-32-00-710-815). 
(3) Operational Check of the DC Bus Transfer. (Refer to the AMM, chapter 24-32-00-
710-825). 
(4) Functional Test – Ground Service Distribution (Refer to the AMM, chapter 24-66-00-
720-815). 
(5) Operational Test – AC Bus Transfer (Refer to the AMM, chapter 24-22-00-710-815).

### Page 23

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 23 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
Typical Installation Battery Relay Panel Fokker 100 
(Relays K 0563A and K 0564A with pn M520U5N installed) 
Figure 1A. 
 
 
Typical Installation Battery Relay Panel Fokker 100 
(Relays K 0563A and K 0564A with pn M600-9336 installed) 
Figure 1B.

### Page 24

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 24 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
 
Typical Installation Emergency Power Box Fokker 100 
For relay K 1552A two different locations and two different part numbers are possible. 
Figure 2 
 
 
 
Typical Installation Upper Part of EPC Fokker 100 
Figure 3

### Page 25 (OCR)

Fokker  Service Bulletin
Fokker 70/100
TB1772A
TB1773A
181//4A
TB0084A
- X0572B
DC_ BTC
K0571A
GBPC-1  + -
K1355A
GPTC
GLC-1  •K0529A
K0308A  0000c
DC EPR  - TB1950B
K1270A  -TB1950A
- EBTC
GHBC-1  GHBC - 2  K0530A
K0605A  K0607A
APTC
-K0531A
DC EBTC
K0567A
odor  00000  • TB0092A
OR
TB1799A  TB1921A
GHBC -1
K0605A  TB1798A  TB1920A
TB1797A  TB1919A
APC  BTC-1
K0527A  K0525A
Middle Part of EPC Fokker 100
Figure 4
Feb 10/11  SBF100-24-043
Revision 1, Dec 15/11  Page 25
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement.
production or disclosure to third parties of this document or any part thereof, or the use of any information contained therein for purposes other than explicitly allowed by the aforesaid agreement, is not permitte
cept with the prior written permission of Fokker Services B.\

### Page 26

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 26 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
 
 
Lower Part of EPC Fokker 100 
Figure 5

### Page 27

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 27 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
Typical Installation Battery Relay Panel Fokker 70 
Figure 6 
 
 
 
Typical Installation Emergency Power Box Fokker 70 
Figure 7

### Page 28

Service Bulletin 
Fokker 70/100 
 
SBF100-24-043 Feb 10/11 
Page 28 Revision 1, Dec 15/11 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
 
Typical Installation Upper Part of EPC Fokker 70 
Figure 8 
 
 
 
 
Typical Installation Middle Part of EPC Fokker 70 
Figure 9

### Page 29

Service Bulletin 
Fokker 70/100 
 
Feb 10/11 SBF100-24-043 
Revision 1, Dec 15/11 Page 29 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
 
Typical Installation Lower Part of EPC Fokker 70 
Figure 10

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.