# Fokker Service Bulletin SBF100-32-169: No revision named

- Rights: © Fokker. Filed by the FAA in regulations.gov docket FAA-2018-0448; AD 2018-19-03 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Fokker Service Bulletin SBF100-32-169](https://openairdocs.org/service-documents/fokker/sbf100-32-169.md)
- Title as filed: SBF100-32-169
- Pages: 13
- PDF: https://openairdocs.org/files/sha256/2e/97/2e97e47baaf7bda75e39718698e15c556ffbb24e34531734bfd3489b3143159e
- Page: https://openairdocs.org/service-documents/fokker/sbf100-32-169/file/2e97e47baaf7

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

FOKKER SERVICES 
  
Service Bulletin  
 Prepared  Function / Note  Date 
    peels-jp02237     23-08-2017 
 Colleague Check    
    bemelman-pb01821     22-08-2017 
 Manager Final Approval    
    peter.hof     23-08-2017 
 Office of Airworthiness Approval   
    visser-hv01800     23-08-2017 
 
 
 
 
Status:  
Released 
Revision:  
- 
Released date: (dd-mm-yyyy) 
23-08-2017 
Security class:  
RESTRICTED 
F100/70 Generic SB no.: 
SBF100-32-169 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained the rein for purposes other than explicitly allowed by the aforesaid agreement, is not permitted except with 
the prior written permission of Fokker Services B.V. 
 
EASA approved procedure for electronic sign-off  
 
 
 
F100/70 Generic SB 
 
 
SBF100-32-169 
 
 
Revision - 
 
 
 
LANDING GEAR - MAIN GEAR 
 
 
 
 
 
One-time Inspection of the Piston for Cracks

### Page 2

FOKKER SERVICES
 
Service Bulletin  
 
 
 
Status:  
Released 
Revision:  
-  
Released date: (dd-mm-yyyy) 
23-08-2017 
Security class:  
RESTRICTED 
F100/70 Generic SB no.: 
SBF100-32-169 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained the rein for purposes other th an explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
1. General Information 
A. General 
(1) This document is digitally prepared, checked and released (Electronic Sign-Off, 
E.S.O.). This means that physical signatures on the document front page are 
replaced by digital signatures. The document is signed and released when the name 
and date of signature of the engineer concerned is filled out on the front page of the 
document. The digital document, workflow, revision history and proof of sign-off are 
stored and controlled in the Fokker product data management system. Electronic 
sign-off is approved by EASA. The procedure and process of E.S.O. are checked 
regularly during internal audits and via EASA oversight. 
 
 
 
B. Table of Contents 
 
 Section 1: General Information 
 Section 2: Planning Information 
 Section 3: Material Information 
 Section 4: Accomplishment Instructions  
 Questionnaire SBF100-32-169 
 Service Bulletin Quality Reporting Form and attachments (if applicable): 
C. Service Bulletin Revision History 
 
Revision Date (dd-mm-yyyy) Reason for Revision 
- Refer to footer First Release 
 
  
 
 
LANDING GEAR - MAIN GEAR 
 
One-time Inspection of the Piston for Cracks.

### Page 3

FOKKER SERVICES
 
Service Bulletin  
 
 
 
Status:  
Released 
Revision:  
-  
Released date: (dd-mm-yyyy) 
23-08-2017 
Security class:  
RESTRICTED 
F100/70 Generic SB no.: 
SBF100-32-169 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained the rein for purposes other th an explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
2. Planning Information 
A. Effectivity 
(1) F28 Mark 0070/0100 aircraft serial number(s): 
 
 
11244 thru 11585 
 
 
 
B. Concurrent Requirements 
(1) Not applicable. 
C. Reason 
(1) During a normal walk around check a large crack was discovered in the lower portion 
of the LH Main Landing Gear (MLG) piston. Visual examination of the piston showed 
a crack running on the aft side from the upper part of the wheel axle platform down 
through the area between and across the lower torque link attachment lugs to the 
bore on the lower side of the piston. Also a horizontal crack running on the aft side of 
the piston, in the transition area from piston tube to wheel axle platform, and cracks 
running through the holes for the brake torque pin, were visible. See figure 2 for more 
details. 
(2) The affected MLG piston accumulated 3216 FC since overhaul and modification from 
pn 41141-3 into pn 41141-5 and 16745 CSN. 
(3) Pistons pn 41141-3 are subject to repetitive inspections per the Airworthiness 
Limitations Section, report SE-623, task 321100-01-16 until modification into pn 
41141-5 as terminating action per SBF100-32-161 and EASA AD 2011-0159.  
(4) Pistons pn 41141-5 are presently not subject to any scheduled inspections.  
(5) The piston will be sent to Goodrich for detailed investigation. The affected operator 
visually inspected all MLG pistons in their fleet without any further findings. 
(6) In order to safeguard fleet airworthiness a detailed visual inspection of Goodrich MLG 
pistons with pn 41141-5 is required as a short term action. After the inspections are 
finalized, the results in combination with the findings of the metallurgical investigation 
of the cracked piston will be used to determine the necessity of additional and/or 
more detailed inspections.  
 
If equipped with Goodrich MLG pn’s: 
41050 -7/-8/-9/-10/-11/-12/-13/-14/-
15/-16 or 41060 -1/-2/-3/-4/-5/-6 in a 
post-mod Goodrich SB41000-32-29 
configuration.

### Page 4

FOKKER SERVICES
 
Service Bulletin  
 
 
 
Status:  
Released 
Revision:  
-  
Released date: (dd-mm-yyyy) 
23-08-2017 
Security class:  
RESTRICTED 
F100/70 Generic SB no.: 
SBF100-32-169 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained the rein for purposes other th an explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
D. Description 
(1) This Service Bulletin tells you how to: 
- Do an inspection of the MLG piston. 
- Report back all findings to Fokker Services. 
 
E. Compliance 
(1) Recommended 
Fokker Services recommends the accomplishment of the Service Bulletin within 6 
weeks after the date of issue of this Service Bulletin, but not later than within the 
compliance time defined in the AD (see note below) which takes precedence over the 
recommendation by Fokker Services. 
NOTE: It is expected that EASA will issue an Airworthiness Directive (AD) with 
respect to this subject with the same compliance terms. Refer to the EASA 
website for the publication of the Airworthiness Directive. 
F. Approval 
(1) The technical content of this document is approved under the authority of DOA ref. 
EASA.21J.059. 
G. Manpower 
(1) Approximately 2,2 man-hours are necessary to do this Service Bulletin on one 
aircraft.  
This table of manpower will help you to schedule and do this Service Bulletin: 
Elapsed time
(hours)
Removal 2 1.0 0.5
Modification
Inspection
Installation 2 1.0 0.5
Testing - - -
Total 2.2 1.1
0.1
Instructions Men Man-hours
2 0.2
 
NOTE: This estimate does not include the time necessary for corrective action.  
(2) The estimated hours are for direct labor done by experienced personnel. They are 
calculated based on the conditions given in SBF100-00-001 (Service Bulletin 
Introduction, section 2.C., “Manpower”).

### Page 5

FOKKER SERVICES
 
Service Bulletin  
 
 
 
Status:  
Released 
Revision:  
-  
Released date: (dd-mm-yyyy) 
23-08-2017 
Security class:  
RESTRICTED 
F100/70 Generic SB no.: 
SBF100-32-169 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained the rein for purposes other th an explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
H. Weight and Balance 
(1) Weight change: None. 
Index change: None. 
I. Electrical Load Data 
(1) Direct Current (DC) Loads: 
(a) Not changed. 
(2) Alternating Current (AC) Loads: 
(a) Not changed. 
J. Software Accomplishment Summary 
(1) Not applicable.  
K. References 
(1) Fokker 70/100 Aircraft Maintenance Manual (AMM) 
Fokker 70/100 Illustrated Parts Catalog (IPC) 
Fokker 70/100 Airworthiness Limitations Section, Part 2 (report SE-623) 
Fokker 70/100 SBF100-32-161 
Goodrich SB 41000-32-28R1 
Goodrich SB 41000-32-29 
Goodrich CMM 32-12-03 
EASA AD 2011-0159

### Page 6

FOKKER SERVICES
 
Service Bulletin  
 
 
 
Status:  
Released 
Revision:  
-  
Released date: (dd-mm-yyyy) 
23-08-2017 
Security class:  
RESTRICTED 
F100/70 Generic SB no.: 
SBF100-32-169 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained the rein for purposes other th an explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
L. Publications Affected 
(1) This Service Bulletin affects the publications listed below: 
(a) Maintenance Documentation 
 
Not affected. 
 
(b) Maintenance Programs 
Not affected 
 
(c) Special Instructions for Continued Airworthiness (ICA) 
The effect of this Service Bulletin on the special ICA is as follows:  
  YES NO 
- Electrical Wiring Interconnection System (EWIS) - X 
- Fokker 70/100 Airworthiness Limitations Section (ALS):   
  Fuel Tank Safety (FTS) - X 
  Damage Tolerance of Fatigue Critical Structure (FCS) - X 
  Certification Maintenance Requirements (CMR) - X 
NOTE: If “YES”, when not already incorporated, the changed ICA will be 
incorporated in the MRB, the Airworthiness Limitations Section (ALS) 
and/or the AMM document(s) within one calendar year from the date of 
issue of this Service Bulletin. Until then, no actions are required. 
(d) Operational Documentation 
Not affected. 
(2) You have the possibility to send your SB feedback to Fokker Services per “Service 
Bulletin Reporting Quality Form”. This form is located on the last Service Bulletin 
page. 
M. Interchangeability or Intermixability of Parts 
(1) Not applicable.

### Page 7

FOKKER SERVICES
 
Service Bulletin  
 
 
 
Status:  
Released 
Revision:  
-  
Released date: (dd-mm-yyyy) 
23-08-2017 
Security class:  
RESTRICTED 
F100/70 Generic SB no.: 
SBF100-32-169 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained the rein for purposes other th an explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
3. Material Information 
A. Material – Price and Availability 
(1) The materials are local source items. 
B. Material Required 
(1) These parts, which are necessary to complete this Service Bulletin on 1 aircraft, are 
not part of the mod kit. 
 
New Part Number Qty Keyword Info Old Part Number Instructions/ 
Disposition 
MS24665-151 8 Split pin - MS24665-151 Local source 
      
      
(2) These mod kit parts are necessary to do this Service Bulletin on 1 aircraft: 
(a) Not applicable 
C. Tooling – Price and Availability 
(1)  Not applicable. 
D. Tooling Required 
(1) Not applicable.

### Page 8

FOKKER SERVICES
 
Service Bulletin  
 
 
 
Status:  
Released 
Revision:  
-  
Released date: (dd-mm-yyyy) 
23-08-2017 
Security class:  
RESTRICTED 
F100/70 Generic SB no.: 
SBF100-32-169 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained the rein for purposes other th an explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
4. Accomplishment Instructions 
 
General: 
- Put up warning signs in the flight compartment and at the hydraulic ground-servicing panel to 
tell persons: “DO NOT PRESSURIZE THE HYDRAULIC SYSTEMS”. 
- Make sure the ground safety pins are installed. 
- These instructions are applicable to the left and right MLG installations. 
WARNING: BE CAREFUL WHEN YOU USE THE CONSUMABLE MATERIALS. OBEY 
THE INSTRUCTIONS AND MANUFACTURER'S HEALTH AND SAFETY 
INSTRUCTIONS. 
NOTE 1: The procedure is given for one MLG. The procedure for the other MLG (if 
applicable) is the same. 
NOTE 2: When the aircraft is on jacks the procedure can be applied to both the LH and RH 
MLG at the same time. 
A. Lift the aircraft with jacks ref. AMM chapter 07-11-00-582-812. 
or 
Lift one MLG with a jack ref. AMM chapter 07-11-00-582-832. 
B. Remove the MLG wheel and brake from the MLG (this to create adequate access for the 
cleaning and inspection of the piston), refer to AMM chapter 32-42-01-000-814. 
C. Remove the protection plate pn 41231-1 from the piston, refer to figure 1 and to IPC 
chapter 32-11-11. Keep the protection plate, bolts, nuts and washers. Discard the split 
pins. 
D. Clean the piston pn 41141-5 in the inspection area in accordance with Goodrich Service 
Bulletin SB 41000-32-28R1. 
E. Inspect the wheel axle platform between the lower torque link attachment lugs for cracks 
in accordance with Goodrich Service Bulletin SB 41000-32-28R1. 
NOTE: See figure 2 of this Service Bulletin for details of the found cracks in the MLG 
piston. 
F. Replace a cracked piston in accordance with AMM chapter 32-11-08-000/400-814. 
G. Install the protection plate on the bottom side of the MLG piston, refer to figure 1 and to 
IPC chapter 32-11-11. Wrench torque the 4 bolts to 9 – 11,3 Nm (80 – 100 inch.lbs). Use 
the parts that you kept in step C and use new split pins pn MS24665-151. 
H. Install the MLG wheel and brake on the MLG, refer to AMM chapter 32-42-01-400-814. 
I. Lower the aircraft, ref. AMM chapter 07-11-00-582-822. 
or 
Lower the MLG, ref. AMM 07-11-00-582-842, and repeat steps A through I on the other 
MLG if applicable.

### Page 9

FOKKER SERVICES
 
Service Bulletin  
 
 
 
Status:  
Released 
Revision:  
-  
Released date: (dd-mm-yyyy) 
23-08-2017 
Security class:  
RESTRICTED 
F100/70 Generic SB no.: 
SBF100-32-169 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained the rein for purposes other th an explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
J. Vibro-peen SBF100-32-169 and date accomplished on nameplate on Main Fitting (refer to 
Goodrich CMM 32-12-03 item (1-20)). 
CAUTION: DO NOT LETTER STAMP NAMEPLATE ON ASSEMBLY. THIS CAN 
DAMAGE THE ASSEMBLY. 
K. Remove warning signs. 
L. Clean the work area from tools, ground equipment, materials and debris. 
M. Complete the attached questionnaire with the applicable information and send to Fokker 
Services. Also report in case of nil finding! 
NOTE: If a crack is found, report to Goodrich in accordance with the instructions in 
Goodrich SB 41000-32-28R1.

### Page 10 (OCR)

FOKKER SERVICES  Yokker
Service Bulletin
> GKN AEROSPACE
70
• 90
VIEW A
110
Typical installation of the protection
plate (only RH side shown)
Protection Plate Installation
Figure 1
Status:  Revision:  Released date: (dd-mm-yyyy)
Released  23-08-2017
Security class:  F100/70 Generic SB no.:
RESTRICTED  SBF100-32-169
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement.
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained therein for purposes other than explicitly allowed by the aforesaid agreement, is not permittec
except with the prior written permission of Fokker Services B.V.
Page 9 of 12

### Page 11

FOKKER SERVICES
 
Service Bulletin  
 
 
 
Status:  
Released 
Revision:  
-  
Released date: (dd-mm-yyyy) 
23-08-2017 
Security class:  
RESTRICTED 
F100/70 Generic SB no.: 
SBF100-32-169 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained the rein for purposes other th an explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Example of Cracks in the Piston 
Figure 2 
Upper side view 
Bottom side view 
Side view 
Location of cracks in the MLG piston 
Inspection: 
Thoroughly clean the inspection area. 
Use a 10X magnifier to examine the 
area for cracks. 
NOTE 1: Pay particular attention to 
areas adjacent to the wiring 
harness hole. 
NOTE 2: The expanding plug may 
remain installed

### Page 12

FOKKER SERVICES
 
Service Bulletin  
 
 
 
Status:  
Released 
Revision:  
-  
Released date: (dd-mm-yyyy) 
23-08-2017 
Security class:  
RESTRICTED 
F100/70 Generic SB no.: 
SBF100-32-169 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained the rein for purposes other th an explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
Questionnaire SBF100-32-169 
 
MLG Piston pn 41141-05 Inspection for Cracks 
 
Send to : Fokker Services 
  Technical Services 
Fax  : 31 (0) 252 627211 
E mail  : technicalservices@fokker.com 
 
 
 
Airline: ______________ A/C sn: ________  
Accomplish date: _____ A/C FH's: ______ A/C FC's: ______ 
 LH MLG RH MLG 
Crack: Yes / No Yes / No 
MLG Pn:   
MLG Sn:   
MLG CSN:   
MLG CSO:   
Piston Pn:   
Piston Sn:   
Piston CSN:   
Piston CSO:

### Page 13

FOKKER SERVICES
 
Service Bulletin  
 
 
 
Status:  
Released 
Revision:  
-  
Released date: (dd-mm-yyyy) 
23-08-2017 
Security class:  
RESTRICTED 
F100/70 Generic SB no.: 
SBF100-32-169 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V. to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained the rein for purposes other th an explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
 
SB Title: One-time Inspection of the Piston for Cracks 
 
Use this Service Bulletin Quality Reporting Form to tell us your perception of the quality of the Service 
Bulletin. The reported data that you provide to us will be used to analyze areas of difficulties and to take 
corrective actions to further improve the quality of our Service Bulletins. We thank you for the time you 
have taken in completing this form. 
 
* Rate the scale of 1 to 4, with 1 the lowest score and 4 the highest score. 
Chapters * 1 2 3 4 
a)  Quality rating of this SB (overall) □ □ □ □ 
b)  Quality rating of the Planning Information □ □ □ □ 
c)  Quality rating of the Material Information □ □ □ □ 
d)  Quality rating of the Accomplishment Instructions □ □ □ □ 
e)  Quality rating of the Test Instructions (if applicable) □ □ □ □ 
f)  Quality rating of the Illustrations or Drawings (if applicable) □ □ □ □ 
g)  Timely delivery of the SB □ □ □ □ 
 
If you have had difficulties with one of the chapters of this Service Bulletin and/or one of your rating(s) is 
lower than 3, please give a short description of the issue. 
 
Comments: 
 
 
 
 
 
 
 
 
 
 
 
Operator: Date: 
 
Name / Title:  
 
 
Please return this form to: Fokker Services B.V. 
Engineering, Quality Department 
P.O. Box 1357 
2130 EL Hoofddorp 
The Netherlands 
Fax: +31 (0) 88 6280111 or E-mail: technicalservices@fokker.com

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.
