# Fokker Service Bulletin SBF27-28-070: SBF27-28-070_Rev_3

- Rights: © Fokker. Filed by the FAA in regulations.gov docket FAA-2015-8137; AD 2016-12-12 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Fokker Service Bulletin SBF27-28-070](https://openairdocs.org/service-documents/fokker/sbf27-28-070.md)
- Title as filed: SBF27-28-070_Rev_3
- Pages: 11
- PDF: https://openairdocs.org/files/sha256/d6/88/d688de2cd83e8fb8e05add32b674b46d0905ccfab91fa9755d58cb9219b89f44
- Page: https://openairdocs.org/service-documents/fokker/sbf27-28-070/file/d688de2cd83e

## Text

Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

Service Bulletin 
 Fokker Services B.V. 
 Prepared  Function / Note  Date 
    gelder-rg02568     Dec 09/14 
 Colleague Check    
    moen-hm02430     Dec 09/14 
 Manager Final Approval    
    benthem-eb01865     Dec 10/14 
 Office of Airworthiness Approval   
    reinier.vanoosten     Dec 11/14 
 
 
 
 
Status:  
Released 
Revision:  
3 
Released date: (Mmm dd/yy) 
Dec 11/14 
Security class:  
UNCLASSIFIED 
F27 Generic SB no.: 
SBF27-28-070 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted except with 
the prior written permission of Fokker Services B.V. 
 
EASA approved procedure for electronic sign-off  
 
 
 
F27 Generic SB 
 
 
SBF27-28-070 
 
 
Revision 3 
 
 
 
FUEL - GENERAL 
 
 
 
 
 
Introduction of Fuel Airworthiness Limitation Items (ALI) and Critical Design 
Configuration Control Limitations (CDCCL) for the F27 Mk200/300/400/500/600/700

### Page 2

Service Bulletin 
Fokker F27 
 
Jun 30/06 SBF27-28-070 
Revision 3, Dec 11/14 Page 1 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
1. Planning Information  
A. Effectivity 
(1) All F27 Mk200/300/400/500/600/700 aircraft within the serial number range: 
10102 thru 10692 
 
NOTE: F27 Mk100 is not affected by the Fuel Tank Safety Program. 
(2) Production version of this modification: Not applicable. 
B. Concurrent Requirements 
(1) Not applicable. 
C. Reason 
(1) In accordance with the requirements of SFAR no. 88 Amendment 21-78 and 
INT/POL/25/12 Fuel Tank Safety, a safety review has been conducted on the F27 
Mk200/300/400/500/600/700 fuel tank system and components that affect fuel tank 
system safety. 
 
 
 
 
 
 
 
 
Page 1 2 3 4 5 6 7 8 9 10        
Revision 3 3 3 3 3 3 3 3 3 3        
 
FUEL 
 
"This Service Bulletin is associated with the Fuel Tank Safety Program."  
Fuel  - Introduction of Fuel Airworthiness Limitation Items (ALI) and Critical Design 
Configuration Control Limitations (CDCCL) for the F27 Mk200/300/400/500/600/700.

### Page 3

Service Bulletin 
Fokker F27 
 
SBF27-28-070 Jun 30/06 
Page 2 Revision 3, Dec 11/14 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
Reason for Revision 
(2) This revision is made to: 
- Update the Fuel Airworthiness Limitation Items (ALI) table.  
 Task descriptions added to Fuel ALI’s 280000-00-01 and 280000-00-02. 
- Update the Critical Design Configuration Control Limitations (CDCCL) table 
  CDCCL 11.1 and 11.2 added. 
- Change the Compliance paragraph. 
- Add ECR016135 to the References paragraph. 
D. Description 
(1) Based on the results of the safety review, this Service Bulletin specifies the Fuel 
Airworthiness Limitation Items (ALI) and the Critical Design Configuration Control 
Limitations (CDCCL) required to prevent the development of unsafe conditions within 
the fuel system. 
Fuel Airworthiness Limitation Items (ALI): as applied to the Fuel Tank system safety 
policy, this term means fuel system mandatory maintenance inspections determined 
necessary to ensure that unsafe conditions do not arise in the fuel system throughout 
the operational life of the airplane. 
Critical Design Configuration Control Li mitations (CDCCL): as applied to the Fuel 
Tank system safety policy, this term refers  to a feature of any aircraft system which 
must be retained during modification, change, repair or scheduled maintenance to 
ensure that an unsafe condition does not develop in the fuel system. 
Operators are expected to demonstrate to their Airworthiness Authority Maintenance 
Inspector that the required configuration control systems are in place to ensure that 
CDCCL’s are properly identified and managed. 
E. Compliance 
(1) Recommended. 
 
Fokker Services recommends to incorporate and to adhere to the information in this 
Service Bulletin in accordance with the compliance terms as specified in the (new or 
revised) EASA Airworthiness Directive. 
 
NOTE: EASA Airworthiness Directive 2014-0105, has been issued with respect to 
this subject. 
 
NOTE: It is expected that EASA will issue a (new  or revised) Airworthiness Directive 
(AD) with respect to this subject.  
Refer to the EASA website for the publication of a Proposed Airworthiness 
Directive for comments.

### Page 4

Service Bulletin 
Fokker F27 
 
Jun 30/06 SBF27-28-070 
Revision 3, Dec 11/14 Page 3 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
F. Approval 
(1) The technical content of this document is approved under the authority of DOA nr. 
EASA.21J.059. 
G. Manpower 
(1) None. 
H. Weight and Balance 
(1) Weight change: None 
Index  change: None. 
I. Electrical Load Data 
(1) Not changed. 
J. Software Accomplishment Summary 
(1) Not applicable.  
K. References 
(1) Fokker internal reference(s): 
 
- Fokker Services report TE-0899. 
- ECR016135 
L. Publications Affected 
(1) This SB affects the publications listed below: 
(a) Maintenance Documentation  
 
- F27 Maintenance Manual (MM). 
- F27 Illustrated Parts Catalog (IPC). 
(b) Maintenance Programs  
 
- F27 Customized Maintenance Program (CMP) 
- F27 Inspection Guide 
- F27 Maintenance Data 
- F27 Maintenance Schedule. 
 
The affected maintenance program change is described in: 
“3. Accomplishment Instructions”.

### Page 5

Service Bulletin 
Fokker F27 
 
SBF27-28-070 Jun 30/06 
Page 4 Revision 3, Dec 11/14 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
(c) Special Instructions for Continued Airworthiness (ICA)  
 
The effect of this Service Bulletin on the special ICA is as follows: 
 
  YES NO 
- Electrical Wiring Interconnection System (EWIS) - X 
- Fuel Tank Safety (FTS) X - 
NOTE: If “YES”, the changed ICA is described in the “Accomplishment 
Instructions” of this SB. 
(d) Operational Documentation  
 
Not affected. 
(2) You have the possibility to send your SB feedback to Fokker Services per “Reporting 
Quality Form”. 
This form is located on the last SB page. 
(3) For incorporation of this Service Bulletin in your documentation refer to 
SBF27-00-001 (Service Bulletin Introduction, section 4 "Incorporation of Service 
Bulletins in Documentation of Fokker Services"). 
M. Interchangeability or Intermixability of Parts 
(1) Not applicable. 
2. Material Information  
A. Material – Price and Availability 
(1) Not applicable. 
B. Material Required 
(1) Not applicable. 
C. Tooling – Price and Availability 
(1) Not applicable. 
D. Drawings Required 
(1) Not applicable.

### Page 6

Service Bulletin 
Fokker F27 
 
Jun 30/06 SBF27-28-070 
Revision 3, Dec 11/14 Page 5 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
3. Accomplishment Instructions  
A. Fuel Airworthiness Limitation Items 
As applied to Fuel Tank system safety policy, this term means fuel system mandatory 
maintenance inspections determined necessary to ensure that unsafe conditions do not arise 
in the fuel system throughout the operational life of the airplane. 
 
FUEL AIRWORTHINESS LIMITATION ITEMS 
Tasknumber Task Description Interval Effectivity Initial* Repeat* 
280000-01 DETAILED INSPECTION OF THE ELECTRICAL 
BONDING (MAIN TANKS). 
A detailed inspection of the electrical bonding 
provisions of fuel lines, ventilation lines and 
components inside or connected to the wing main 
tanks and of the bonding provisions of the collector 
tanks shall be carried out to verify all bonding 
provisions required per design are present, properly 
installed and in good condition.  
 
Anomalies shall be corrected. 
 
01/01/2013 
Note 1 
8 YR ALL 
280000-02 DETAILED INSPECTION OF THE DRAIN HOLES 
AND DRAIN PATHS IN THE DRY BAY ZONE. 
A detailed inspection of the drain holes and drain 
paths in the dry bay zones adjacent to wing main 
tanks shall be carried out to verify the following: 
o Dry bay is clean  
o Drain holes and drain paths are clean and free of 
any obstruction 
 
Anomalies shall be corrected. 
 
01/01/2008 2 YR ALL 
 
* Not later than 
Note 1: The initial inspection shall be done not later than January 1, 2013 except for bonding 
provisions introduced through SBF27-28-071 and SBF27-28-072. For bonding installed 
with SBF27-28-71 or SBF27-28-072 the initial inspection date is the accomplishment date 
of that applicable Service Bulletin with which the bonding provisions have been 
introduced.

### Page 7

Service Bulletin 
Fokker F27 
 
SBF27-28-070 Jun 30/06 
Page 6 Revision 3, Dec 11/14 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
B. Exceptional short-term extensions 
Since Fuel ALI Maintenance/Inspection intervals are generally not determined from 
calculations in which failure rate data is known with a high level of confidence, an 
exceptional short-term extension for a specific Fuel ALI interval may be made on one 
aircraft for a limited period of time without jeopardising safety. 
 
The term 'exceptional short-term extension' is defined as an increase in a Fuel ALI interval 
that may be needed to cover an uncontrollable or unexpected situation. Repeated use of 
such extensions, either on the same aircraft or on similar aircraft in the operator's fleet, 
should not be used as a substitute for good management practices. 
 
Unless noted adjacent to the task, for all Fuel ALI’s identified in this document, it has been 
accepted by the Primary Certification Office (EASA) that short-term extensions up to the 
following maximum values may be granted without consultation with that office. Requests 
for extensions in excess of these values must be submitted with full justification to the 
Primary Certification Office (EASA) such that approval, if granted, can be given prior to 
their use.  
 
- Fuel ALI’s controlled by Flight Hours (FH) 
 
Extensions up to 10% or 500 FH (whichever is the lesser) may exceptionally be granted 
on Fuel ALI intervals quoted in terms of flight hours. 
 
- Fuel ALI’s controlled by Flight Cycles (FC) 
 
Extensions up to 5% or 250 FC (whichever is the lesser) may exceptionally be granted 
on Fuel ALI intervals quoted in terms of flight cycles or landings. 
 
- Fuel ALI’s controlled by Calendar Time (MO) 
Where the repeat interval is 12 months or less, extensions up to 10% or 1 month 
(whichever is the lesser) may exceptionally be granted on Fuel ALI intervals quoted in 
terms of months. 
Where the repeat interval is greater than 12 m onths but less than 3 years, extensions up 
to 2 months may exceptionally be granted. 
Where the repeat interval is 3 years or greater, extensions up to 3 months may 
exceptionally be granted. 
It is the operator's responsibility to identify appropriate procedures with his local 
regulatory authority for the control and development of his maintenance program. (Note 
EASA: The operator should keep a record of short term extensions given for Fuel 
Airworthiness Limitations) 
This paragraph in the Fuel Airworthiness Limitation Item document is written to confirm 
to the local regulatory authority that exceptional short-term extensions of Fuel ALI 
intervals are permissible. Approval of such extensions rests with the local authority in the 
same way as it does for any other scheduled maintenance task interval extension.

### Page 8

Service Bulletin 
Fokker F27 
 
Jun 30/06 SBF27-28-070 
Revision 3, Dec 11/14 Page 7 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
C. Critical Design Configuration Control Limitations (CDCCL) 
As applied to the Fuel Tank system safety policy, this term refers to a feature of any 
aircraft system which must be retained during modification, change, repair or scheduled 
maintenance to ensure that an unsafe condition does not develop in the fuel system. 
 
CRITICAL DESIGN CONFIGURATION CONTROL LIMITATIONS 
CDCCL 
number 
Component(s) CDCCL Description Effectivity Vendor 
 
(note 1) 
CDCCL-approved
part numbers 
(note 1) 
1.1 FQIS probes in 
wing main tanks 
It shall be ensured that only FQIS 
probes with a part number 
approved by the TCH under Fuel 
Tank Safety requirements for 
installation in the wing main tanks 
will be installed on the aircraft. 
All a/c Honeywell 
Inc 
Commercial 
Aviation 
FG250A4 
FG220A77 
FG220A88 
 
1.2 FQIS probes in 
wing main tanks 
It shall be ensured that the 
approved component maintenance 
and repair procedures are adhered 
to during shop maintenance. 
All a/c Honeywell 
Inc 
Commercial 
Aviation 
FG250A4 
FG220A77 
FG220A88 
2.1 FQIS probe / 
level sensor 
inboard tank 
It shall be ensured that only a FQIS 
probe / level sensor assembly with 
a part number approved by the TCH 
under Fuel Tank Safety 
requirements for installation in the 
inboard tank will be installed on the 
aircraft. 
A/c with 
inboard tanks 
Flight 
Refuelling 
(Eaton 
Aerospace 
Ltd) 
9201000-198 
9201000-199 
9201000-200 
9201000-201 
9201000-206 
2.2 FQIS probe / 
level sensor 
inboard tank 
It shall be ensured that the 
approved component maintenance 
and repair procedures are adhered 
to during shop maintenance. 
A/c with 
inboard tanks 
Flight 
Refuelling 
(Eaton 
Aerospace 
Ltd) 
9201000-198 
9201000-199 
9201000-200 
9201000-201 
9201000-206 
3 FQIS wiring 
outside fuel 
tanks 
It shall be ensured that repairs of 
wiring near to any FQIS wiring 
external to the fuel tanks will not 
increase the risk of a hot short of 
FQIS wires. 
All a/c N.A. N.A. 
4 Bonding of 
collector tanks 
and of fuel 
lines, ventilation 
lines and 
components, 
wing main tanks  
It shall be ensured that the 
configuration and quality of the 
bonding provisions of fuel lines, 
ventilation lines and components 
inside or connected to the wing 
main tanks and the bonding 
provisions of the collector tanks are 
conforming to the design (ref. NC 
4.610/xxx). 
All a/c N.A. N.A.

### Page 9

Service Bulletin 
Fokker F27 
 
SBF27-28-070 Jun 30/06 
Page 8 Revision 3, Dec 11/14 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
CRITICAL DESIGN CONFIGURATION CONTROL LIMITATIONS 
CDCCL 
number 
Component(s) CDCCL Description Effectivity Vendor 
 
(note 1) 
CDCCL-approved
part numbers 
(note 1) 
5 Bonding of fuel 
lines, ventilation 
lines and 
components, 
inboard tanks 
It shall be ensured that the 
configuration and quality of the 
bonding provisions of fuel lines, 
ventilation lines and components 
inside or connected to the inboard 
tanks are conforming to the design 
(ref. NC 4.610/xxx). 
A/c with 
inboard tanks 
N.A. N.A. 
6.1 Anti-spray cover 
of main tank 
fueling shut-off 
valve 
It shall be ensured that an anti-
spray cover is properly installed 
over the discharge port of the 
fueling shut-off valve of each main 
wing tank, conform the design. 
A/c post 
SBF27-28-071 
N.A. N.A. 
6.2 Anti-spray cover 
of main tank 
fueling shut-off 
valve 
It shall be ensured that only an anti-
spray cover with a part number 
approved by the TCH under Fuel 
Tank Safety requirements will be 
installed on the aircraft. 
A/c post 
SBF27-28-071 
Fokker 
Services 
Refer to 
SBF27-28-071 
7.1 Collector Tank 
Level float 
switch 
It shall be ensured that only a 
collector tank level float switch 
assembly with a part number 
approved by the TCH under Fuel 
Tank Safety requirements will be 
installed on the aircraft. 
A/c with 
inboard tanks 
Eaton 
Aerospace 
Ltd 
3515000-127 
3515000-135 
7.2 Collector Tank 
Level float 
switch 
It shall be ensured that the 
approved component maintenance 
and repair procedures are adhered 
to during shop maintenance. 
A/c with 
inboard tanks 
Eaton 
Aerospace 
Ltd 
3515000-127 
3515000-135 
8.1 Level control 
pilot valve 
It shall be ensured that only a level 
control pilot valve with a part 
number approved by the TCH under 
Fuel Tank Safety requirements will 
be installed on the aircraft. 
All a/c Parker 
Hannifin 
Corporation 
F62B0050, 
F62B0050M1, 
F62B0050M2, 
F62B0050M3 
8.2 Level control 
pilot valve 
It shall be ensured that the 
approved component maintenance 
and repair procedures are adhered 
to during shop maintenance. 
All a/c Parker 
Hannifin 
Corporation 
F62B0050, 
F62B0050M1, 
F62B0050M2, 
F62B0050M3 
8.3 Fuse in wiring 
of LCPV 
solenoid 
It shall be ensured that the over-
current protection fuse (in-line 
junction with integral fuse) is 
properly installed in the power 
supply wire of each LCPV solenoid, 
close to the point where the wiring 
enters the tank, and is undamaged. 
A/c post 
SBF27-28-069 
(note 2) 
Fokker 
Services 
DME-F07 
8.4 Fuse in wiring 
of LCPV 
solenoid 
It shall be ensured that only a fuse 
junction with a part number 
approved by the TCH under Fuel 
Tank Safety requirements for the 
specific application will be installed 
in the power supply wire of the 
LCPV solenoid. 
A/c post 
SBF27-28-069 
(note 2) 
Fokker 
Services 
DME-F07

### Page 10

Service Bulletin 
Fokker F27 
 
Jun 30/06 SBF27-28-070 
Revision 3, Dec 11/14 Page 9 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
CRITICAL DESIGN CONFIGURATION CONTROL LIMITATIONS 
CDCCL 
number 
Component(s) CDCCL Description Effectivity Vendor 
 
(note 1) 
CDCCL-approved
part numbers 
(note 1) 
9.1 Fuel Quantity 
Indicator wing 
main tank 
It shall be ensured that only a wing 
main tank Fuel Quantity Indicator 
with a part number approved by the 
TCH under Fuel Tank Safety 
requirements will be installed on the 
aircraft. 
All a/c Honeywell 
Inc 
Commercial 
Aviation 
JG130A76 
JG130A77 
JG130A94 
JG130A97 
JG130A98 
JG130A100 
9.2 Fuel Quantity 
Indicator wing 
main tank 
It shall be ensured that the 
approved component maintenance 
and repair procedures are adhered 
to during shop maintenance. 
All a/c Honeywell 
Inc 
Commercial 
Aviation 
JG130A76 
JG130A77 
JG130A94 
JG130A97 
JG130A98 
JG130A100 
10 Drain holes and 
drain paths of 
wing dry bay 
zones 
It shall be ensured that the drain 
holes and drain paths of the dry bay 
zones adjacent to the wing tanks 
are open and unobstructed. 
All a/c N.A. N.A. 
11.1 Flame trap 
inboard tank 
compartment 
drain line. 
It shall be ensured that a flame trap 
is properly installed in the inboard 
tank compartment drain line. 
A/c with inboard 
tanks 
N.A. N.A. 
11.2 Flame 
trap/flame 
arrester inboard 
tank 
compartment 
drain line. 
It shall be ensured that only a flame 
trap or flame arrester with a part 
number approved by the TCH under 
Fuel Tank Safety requirements will 
be installed on the aircraft. 
A/c with 
inboard tanks 
Fokker 
Services 
 
 
 
 
 
AMAL 
8680-127-401 
8680-127-407 
8680-127-409 
8680-127-411 
8680-127-412 
188-26-15-45FA- 
 
188-206-15-45SS 
188-26-15-45SS316 
 
Notes: 
 
1) Vendor and part number data is only provided where the CDCCL consists of control of part 
number(s) at the installation or of control of application of proper maintenance / repair 
procedures of the part. 
 
2) Operators that have introduced changes to the manuals in accordance with the instructions in 
the original issue of MCNM-F27-025 (attached to the original issue of SBF27-28-069) must 
make additional changes to the manuals in accordance with the instructions in revision 1 of 
MCNM F27-025. 
D. Abbreviations. 
A/c Aircraft 
FQIS Fuel Quantity Indication System 
LCPV Level Control Pilot Valve 
NC Norm Constructie (Dutch) / Design Standard 
TCH Type Certificate Holder 
YR Year

### Page 11

Service Bulletin 
Fokker F27 
 
SBF27-28-070 Jun 30/06 
Page 10 Revision 3, Dec 11/14 
 
Copyright All rights reserved by Fokker Services B.V. (The Netherlands). This document has been supplied by Fokker Services B.V . to its customers on a confidential basis subject to the provisions of an agreement. 
Reproduction or disclosure to third parties of this document or any part thereof, or the use of any information contained there in for purposes other than explicitly allowed by the aforesaid agreement, is not permitted 
except with the prior written permission of Fokker Services B.V. 
 
Service Bulletin Reporting Quality Form 
 
Use this Service Bulletin Reporting Quality Form to tell us your perception of the quality of the Service 
Bulletin. The reported data that you provide to us will be used to analyze areas of difficulties and to take 
corrective actions to further improve the quality of our Service Bulletins. We thank you for the time you have 
taken in completing this form. 
 
* Rate the scale of 1 to 4, with 1 the lowest score and 4 the highest score. 
Chapters * 1 2 3 4 
a)  Quality rating of this SB (overall) □ □ □ □ 
b)  Quality rating of the Planning Information □ □ □ □ 
c)  Quality rating of the Material Information □ □ □ □ 
d)  Quality rating of the Accomplishment Instructions □ □ □ □ 
e)  Quality rating of the Test Instructions (if applicable) □ □ □ □ 
f)  Quality rating of the Illust rations or Drawings (if applicable) □ □ □ □ 
g)  Timely delivery of the SB □ □ □ □ 
 
If you have had difficulties with one of the chapters of this Service Bulletin and/or one of your rating(s) is 
lower than 3, please give a short description of the issue. 
 
Comments: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Operator: Date:  
 
Name / Title:  
 
 
Please return this form to: Fokker Services B.V. 
Technical Services, Quality Department 
P.O. Box 1357 
2130 EL Hoofddorp 
The Netherlands 
Fax: +31 (0) 88 6280111  or  Email : technicalservices@fokker.com

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.
