# General Electric Service Bulletin 5000ELM-28-075: Revision 1

- Rights: © General Electric Company. Filed by the FAA in regulations.gov docket FAA-2015-1273; AD 2016-11-03 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [General Electric Service Bulletin 5000ELM-28-075](https://openairdocs.org/service-documents/ge/5000elm-28-075.md)
- Title as filed: 5000ELM-28-075 Rev1
- Pages: 14
- PDF: https://openairdocs.org/files/sha256/22/3c/223c2776bb5e9bdae4e2ddcc99583b11b2560820160316e2ecb06df91ba9426a
- Page: https://openairdocs.org/service-documents/ge/5000elm-28-075/file/223c2776bb5e

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

.  SERVICE BULLETIN  . 
  
 
 
 
 
 
 
 
TO: ALL HOLDERS OF SERVICE BULLETIN 5000ELM-28-075, 
DATED May 06/14. 
FROM: GE AVIATION SYSTEMS LTD 
 
This page transmits Revision No. 1 to Service Bulletin 5000ELM-28-075.  Revision No. 1 replaces Service 
Bulletin 5000ELM-28-075, dated May 06/14 in its entirety. 
 
This revision: 
1. Corrects the list of designated aircraft affected on Pages 1 and 2. 
2. Amends Figure 2 on Page 5 to show improved clarity and location of the specified SIUs.  
 
Changed material is indicated with revision bars.

### Page 2

(No text on this page.)

### Page 3

GE Aviation 
  CAGE CODE: K5294 GEK 131222 
Global Contact:  systems.support@ge.com 
GE Ref: SCD S281W601 Revision BB plus ADRN 16H 
Manual Ref: N/A 
SERVICE BULLETIN 
 
Copyright (2014), GE Aviation Systems Ltd., U.K. 
The information contained in this document is GE Aviation Systems Ltd proprietary information and is disclosed in confidence. It is the 
property of GE Aviation Systems Ltd and shall not be used, disclosed to others or reproduced without the express written consent of GE 
Aviation Systems Ltd, including, but without limitation, it is not to be used in the creation, manufacture, development, or derivation of any 
repairs, modifications, spare parts, design, or configuration changes or to obtain FAA or any other government or regulatory approval to 
do so. If consent is given for reproduction in whole or in part, this notice and the notice set forth on each page of this document shall 
appear in any such reproduction in whole or in part. The information contained in this document may also be controlled by U.S. export 
control laws. Unauthorized export or re-export is prohibited. 
Destination Control Statement 
This technical data is considered EAR controlled pursuant to 15 CFR Parts 730-774. Transfer of this data by any means to another party 
without the proper U.S. Government authorization is strictly prohibited. 
 5000ELM-28-075 
May 06/14 
Revision No. 1  Aug 05/14 Page 1 of 12 
FUEL SYSTEMS - P110 LEFT POWER MANAGEMENT PANEL 
 
5***ELM2* 
 
ADDITION OF FUEL SCAVENGE WIRING 
 
1. PLANNING INFORMATION 
WARNING: FAILURE TO CORRECTLY IMPLEMENT ANY INSTRUCTION GIVEN HERE, AS 
AMENDED FROM TIME TO TIME BY GE AVIATION, MAY ENDANGER HEALTH OR 
SAFETY. 
A. Effectivity 
(1) Aircraft affected: Boeing 777-200, F, -200LR, -300 and -300ER 
(2) Unit affected:  P110 Left Power Management Panel 
(3) Unit part numbers: GE Part No. Boeing Part No 
52**ELM2* S281W601-52** 
53**ELM2* S281W601-53** 
54**ELM2* S281W601-54** 
55**ELM2* S281W601-55** 
56**ELM2* S281W601-56** 
57**ELM2* S281W601-57** 
59**ELM2* S281W601-59**

### Page 4

.  SERVICE BULLETIN  . 
  
 5000ELM-28-075 
May 06/14 
Revision No. 1  Aug 05/14 Page 2 
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
B. Reason 
(1) Condition conversion corrects 
The ELMS panels are unable to provide power for Fuel Scavenge system. 
(2) Extent condition encountered 
Boeing 777-200, F, -200LR, -300 and -300ER. 
(3) Expected benefits of conversion 
The ELMS panels will be able to provide power for the Fuel Scavenge System. 
C. Description 
The conversion requires the installation of a single 22 AWG wire between SIU 2 and 
connector D11007. 
The GE part number and Boeing part number remain unchanged as a result of this work.  
D. Compliance 
Optional – Service Bulletin to revise functionality. 
E. Approval 
The repairs and modifications herein are minor per 14 CFR 21.93/CS 21.93 and comply with 
the applicable regulations and are on record with the supplier as FAA-approved, by process 
via 14 CFR 21.95/CS 21.95. 
F. Manpower 
The incorporation of this work will take approximately 1 man hour excluding testing. 
G. Material and Availability 
For details of the materials required to embody this conversion, refer to paragraph 3 of this 
Service Bulletin. 
H. Re-identified Parts 
None. 
I. Tooling Required 
In addition to the standard airplane electrical wiring tools, the following specialist tooling (or 
equivalent) is required: 
(1) Crimp Plier, part number M22520/1-01.   
(2) Crimp Plier, part number M22520/2-01.  
(3) Insertion/Extraction Tool, part number M81969/14- 01 (Green/White). 
(4) Insertion/Extraction Tool, part number M81969/14-10 (Red/Orange). 
(5) Positioner, part number M22520/1-02. 
(6) Positioner, part number M22520/2-07.

### Page 5

.  SERVICE BULLETIN  . 
  
 5000ELM-28-075 
May 06/14 
Revision No. 1  Aug 05/14 Page 3 
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
J. Weight and Balance 
Not affected. 
K. Electrical Load Data 
Not changed. 
L. Reference 
(1) BCAG Aircraft Maintenance Manual (AMM). 
(2) Boeing Service Bulletin 777-28-0078 (Line Numbers 423, 429 and 454 to 1098) 
(3) Boeing Service Bulletin 777-28-0083 (Line Number 1099 and on) 
M. Other Publications Affected 
None.

### Page 6 (OCR)

SERVICE BULLETIN
SEE (A
MAIN EQUIPMENT CENTER
ACCESS DOOR, 117AL
FWD
LEFT POWER
MANAGEMENT
MAIN EQUIPMENT CENTER  PANEL, P110
SEE
P110 Left Power Management Panel
(Left Hand Door not illustrated)
P110 Power Management Panel
Figure 1
5000ELM-28-075
May 06/14
Revision No. 1 Aug 05/14  Page 4
GE Proprietary Information - subject to the restrictions on the cover or first page

### Page 7 (OCR)

ув
SERVICE BULLETIN
Front
DM24505C  DM24504A
DM24505B  DM24504B
DM24505A  DM24504C
SIU2 M24505  SIU 1 M24504
-A
View behind louvered panel,  View with louvered panel removed,
from underneath  from front
J07
D11007
0000
0000001000100
CAUTION
ASSEMBLY CONTAINS ESDS
Typical Cabinet Assembly
Figure 2
5000ELM-28-075
May 06/14
Revision No. 1 Aug 05/14  Page 5
GE Proprietary Information - subject to the restrictions on the cover or first page

### Page 8

.  SERVICE BULLETIN  . 
  
 
 5000ELM-28-075 
May 06/14 
Revision No. 1  Aug 05/14 Page 6 
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fuel Scavenge System 
Figure 3

### Page 9

.  SERVICE BULLETIN  . 
  
 
 5000ELM-28-075 
May 06/14 
Revision No. 1   Aug 05/14 Page 7 
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
2. ACCOMPLISHMENT INSTRUCTIONS 
WARNINGS: FAILURE TO FOLLOW THE APPLICABLE INSTRUCTIONS GIVEN IN THIS 
PUBLICATION AS AMENDED BY GE REVISIONS MAY ENDANGER SAFETY.  
THIS DOCUMENT ONLY COVERS IMPLEMENTATION OF THE REFERENCED 
CHANGE.  IT DOES NOT ADDRESS PRE OR POST-IMPLEMENTATION TASKS. 
TO ENSURE THE SAFETY OF PERSONNEL IMPLEMENTING THE WORK, 
REFERENCE MUST BE MADE TO ALL INSTRUCTIONS REGARDING SAFETY 
RELATED PROCEDURES (E.G. POWER DOWN) DETAILED IN THE AIRCRAFT 
MAINTENANCE MANUAL. 
YOU MUST CONSULT AND OBEY THE MANUFACTURER’S OR SUPPLIER’S 
SAFETY DATA SHEET (SDS) FOR ANY OF THE MATERIALS THAT YOU USE.  
CAUTION: DURING THIS CONVERSION ALL CIRCUIT BREAKER RETAINING NUTS , 
CIRCUIT BREAKER TERMINAL SCREWS AND CABLE CLAMP PILLAR SCREWS  
MUST BE TORQUE LOADED. REFER TO THE EMBODIMENT INSTRUCTIONS 
THAT FOLLOW FOR SPECIFIC TORQUE REFERENCES. 
NOTES: 1. During the embodiment of this Service Bulletin most labels that are to be 
fitted must be positioned in the same location as the old label they are 
replacing, the old label must be entirely removed. However, labels containing 
circuit breaker titles and/or bus information may be placed over the existing 
label if necessary. 
 2. During the embodiment of this Service Bulletin any anti -abrasion tape, lacing 
tape or heatshrink, which has to be removed, is to be replaced from 
customers own resources. 
A. Embodiment Instructions 
(1) Refer to Figure 1 and on the P110 Left Power Management Panel, proceed as 
follows: 
(a) Release the 4 -off fasteners on the Left Hand (LH ) door. Open and  engage 
the LH door stay. 
(b) Release the 4-off fasteners on the Right Hand (RH ) door. Open and engage 
the RH door stay. 
(2) Refer to Figure 2 and locate SIU 2 (M24505). 
(3) Remove connector DM24505B from SIU 2. 
(4) From the conversion kit, select the items that follow: 
(a) 22 AWG Wire marked W3145-0761-22, part number 1344-1943-01. 
(b) 1-off size 22 contact socket, part number 30-867-6654U. 
(5) Refer to Figure 3 and proceed as follows: 
(a) Prepare one end of the new wire marked W3145-0761-22. 
(b) Using Crimp Plier M22520/2-01 at wire setting 4, together with Positioner 
M22520/2-07, crimp the size 22 contact socket onto the prepared end of the 
new wire.

### Page 10

.  SERVICE BULLETIN  . 
  
 
 5000ELM-28-075 
May 06/14 
Revision No. 1   Aug 05/14 Page 8 
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
(c) Insert wire, using plastic tool M81969/14-01 green end, into the Connector 
DM24505B pin 31. 
(6) Refer to F igures 2 and 3 . Route the wire marked W3145-0761-22 from the 
Connector DM24505B  to the Connector D11007 noting that the wires MUST be: 
(a) Contained within the ORANGE cableform. 
(b) Routed INSIDE cable clamps, abrasion resistant tape and lacing tape. 
(c) Installed so as not to create unacceptable crossovers with existing wires in the 
cableform. 
NOTE: It will be necessary to loosen the cable clamp arrangements to allow 
the new wiring to be fed through. 
(d) After routing is complete, cut the routed wire to a suitable length to be 
terminated into Connector D11007. 
(7) Refer to Figure  2. L ocate and disconnect the Airplane Interface Connector 
D11007 at position J07. 
(8) From the conversion kit, select the item that follows: 
(a) 1-off Size 20 Contact Pin, part number 30-867-6753-01. 
(9) Refer to Figure 3 and proceed as follows: 
(a) At C onnector D11007  prepare the end of the routed wire  marked  
W3145-0761-22.  
(b) Using Crimp Plier M22520/ 1-01 at wire setting 3, together with Positioner 
M22520/1-02 set to red, crimp the  size 20 contact pin  at the prepared end of 
the wire. 
(c) Using Insertion Tool M81969/14-10 (Red  end), connect the terminated wire 
W3145-0761-22 into the Connector D11007, contact 7. 
(10) Refer to Figure 3. Do the continuity checks that follow: 
(a) Make sure there is continuity (i.e. a resistance less than 1 ohm) between the 
following terminals. 
From To 
D11007 contact 7 DM24505B pin 31 
 
(11) From the conversion kit, select the items that follow: 
(a) D11007 Mate-With label, part number ELM850-1. 
(12) Refer to Figures 2 and 3 and proceed as follows: 
(a) Install the D11007 Mate-With Label onto the new wir ing as close as possible to 
their termination on Airplane Interface Connector D11007  to identify the new 
wires incorporated onto the connector.

### Page 11

.  SERVICE BULLETIN  . 
  
 
 5000ELM-28-075 
May 06/14 
Revision No. 1   Aug 05/14 Page 9 
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
(13) Make sure that: 
(a) All disturbed cable clamp pillar screws are torque loaded to between 35.1 and 
42.9 lbf inch (4.0 and 4.8 Nm). 
(b) All disturbed circuit breakers are closed. 
(c) All disturbed nuts and screws are tightened to relevant torque settings. 
(d) All disturbed connectors are reassembled as nec essary and reconnected 
(DM24505B, D11007). 
(e) All cables and splices are securely tied-in to suitable positions. 
(f) A full internal cabinet visual inspection is carried out and all debris is removed.  
(14) Proceed as follows: 
(a) Disengage the LH door stay and close the LH door. Secure the 4-off fasteners 
on the LH door. 
(b) Disengage the RH door stay and close the RH d oor. Secure the  
4-off fasteners on the RH door. 
(c) Apply ‘tamperproof’ inspection seals to the LH and RH doors as required from 
customers own resources.

### Page 12

.  SERVICE BULLETIN  . 
  
 
 5000ELM-28-075 
May 06/14 
Revision No. 1   Aug 05/14 Page 10 
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
(15) Operators may choose one of the three following methods to indicate that the service 
bulletin work has been completed. Either: 
(a) From conversion kit S.B. 5000ELM -28-075A select the Work Carried Out 
Label marked S.B. 5000ELM-28-075, part number ELM139 -13.  Install the 
Label marked S.B. 5000ELM-28-075 in a convenient position below the Unit 
Code Label and Modification Label on the front lo wer part of the exterior 
cabinet frame.  Make sure that it is positioned in the same orientation and 
below any other label(s) which may have been install ed to the cabinet as a 
result of previous work. 
or 
(b) From the operators own resources, produce an appropr iate label marked 
S.B. 5000ELM-28-075.  Refer to Figure 4 only as a guide, locally produced 
labels may vary in size and style.  Install this label in a convenient position 
below the Unit Code Label and Modification Label on the lower part of the 
exterior cabinet frame.  Make sure that it is positioned in the same orientation 
and below any other label(s) which may have been installed to the cabinet as 
a result of previous work.  Refer to Boeing standard BAC5307 as a guideline 
for part marking. 
or 
(c) Using a suitable method, indelibly mark S.B. 5000ELM-28-075 on the front 
lower part of the exterior cabinet frame.  Refer to Boeing standard BAC53 07 
as a guideline for part marking. 
 
Work Carried Out Label 
Figure 4

### Page 13

.  SERVICE BULLETIN  . 
  
 
 5000ELM-28-075 
May 06/14 
Revision No. 1   Aug 05/14 Page 11 
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
 
3. MATERIAL INFORMATION 
WARNING: ONLY SPARES AND COMPONENTS SPECIFIED BY GE AVIATION SYSTEMS 
LIMITED SHOULD BE USED. 
NOTE:  
ORDERING 
Certain spare part s listed in the Service Bulletin  are manufactured by other contractors and have 
the manufacturer’s number or British Standards reference quoted in addition to the part number 
under which GE Aviation Systems Limited supply. 
When ordering from GE please quote the GE par t number, the other manufacturer’s number or 
British Standards reference and the Code number of the unit, on all orders or enquiries.  
When ordering from other manufacturers please quote the manufacturer’s number and/or British 
Standards reference only. 
A. Conversion kit 5000ELM-28-075A consists of the following parts:- 
 
New 
Part Number Qty Key Word Old Part Number Disposition Instruction 
1344-1943-01 4 m 22 AWG Wire marked W3145-0761-22 - - 
30-867-6654U   1 Contact socket  size 22 - - 
30-867-6753-01 1 Contact pin size 20 - - 
ELM139-13 1 
Work Carried Out Label  
marked 
S.B. 5000ELM-28-075 
- - 
ELM850-1 1 D11007 Mate-With Label - -

### Page 14

.  SERVICE BULLETIN  . 
  
 
 5000ELM-28-075 
May 06/14 
Revision No. 1   Aug 05/14 Page 12  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
SUPPLEMENT - PRICE AND AVAILABILITY 
FUEL SYSTEMS - P110 LEFT POWER MANAGEMENT PANEL 
5***ELM2* 
 
ADDITION OF FUEL SCAVENGE WIRING 
 
This is a technical document not a quotation; prices and delivery times given are in good faith without 
engagement. 
Conversion kit part number 5000ELM-28-075A, comprising the items listed in paragraph  3. of this Service 
Bulletin, will be available for shipment within 90 days from receipt of order at a price which will be quoted upon 
application. This price may be subject to change without notice. 
All orders should specify the kit part number and be addressed to: 
 
GE Aviation Systems Ltd 
Bishops Cleeve 
Cheltenham 
Glos. 
GL52 8SF 
UK 
 
AVIATION.NEWPO@ge.com

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.