# General Electric Service Bulletin 6000ELM-24-614: Revision 1

- Rights: © General Electric Company. Filed by the FAA in regulations.gov docket FAA-2013-0544; AD 2014-16-11 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [General Electric Service Bulletin 6000ELM-24-614](https://openairdocs.org/service-documents/ge/6000elm-24-614.md)
- Title as filed: U.S. DOT/FAA - GE-6000ELM-24-614 Rev 1
- Pages: 22
- PDF: https://openairdocs.org/files/sha256/ca/b6/cab6e89d9ee9ed5dcab52ddd1f9a9a0e398f04bfe66bf1c7ead9f08040e3210b
- Page: https://openairdocs.org/service-documents/ge/6000elm-24-614/file/cab6e89d9ee9

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

.  SERVICE BULLETIN  .  
 
 
Revision 1.  Nov 09/09 6000ELM-24-614 
 
Formerly Smiths Aerospace 
 
 
TO: ALL HOLDERS OF SERVICE BULLETIN 6000ELM-24-614, 
DATED 8th May 2003. 
FROM: GE AVIATION SYSTEMS LTD 
On May 4th 2007 the Aerospace business of Smiths Group, formally known as 
Smiths Aerospace Ltd, was sold to General Electric Corporation and became GE 
Aviation Systems Ltd, doing business as GE Aviation. 
This page transmits Revision No. 1 to Service Bulletin 6000ELM-24-614.  Revision No. 1 replaces Service 
Bulletin 6000ELM-24-614, dated 8th May 2003 in its entirety. 
This revision corrects the following errors: 
1. The circuits shown as Figure 2 and Figure 3 fail ed to show the presence of a circuit breaker in 
position C1. Additionally they both failed to show that  the circuit breaker shown in position E8 is only 
fitted in 6069ELM1 panels. The procedure has been amended so that Row D is worked first in order 
that the 5-tag busbar, which is removed from Row D, is used on Row C.  
2. On Page 14 paragraph 2.A.(30) details the selecti on of labels which are used to identify the circuit 
breakers on a specific row. Paragraph (30)(f) listed the following: 
Label Row E, part no. ELM812-36E 
when this should have read 
Label Row E, part no. ELM812-40E 
3. Paragraphs (31) through (36) detail the fitting of the labels, making reference to the specific panel 
part numbers to which each label is applicable. References to panels 6069ELM1 should have read 
6058ELM1 and references to panels 6058ELM1 should have read 6069ELM1. 
Both the above errors were repeated in the conversion kit details on page 18. 
NOTE: Operators of 6058ELM1 or 6069ELM1 panels who carried out the work affected by the errors referred 
to above in paragraphs (30) through (36) from the original document (i.e. pre revision 1) will need to 
carry out the procedures in new paragraphs (37) and (38) to return their panels to the correct 
standard. 
 
 
Changed material is indicated with revision bars.

### Page 2

(No text on this page.)

### Page 3

GEK 115335
For Europe, Africa, India and  
Middle East contact: 
GE Aviation 
Customer Services - Cheltenham 
Bishops Cleeve, Cheltenham, 
Glos GL52 8SF, United Kingdom 
T: + 44 (0)1242 673355 
F: + 44 (0)1242 669165 
For Asia, Australasia and the Pacific 
contact: 
GE Aviation 
3 Hakea Street, 
Brisbane Airport, QLD4007, 
Australia 
T: + 61 7 3860 0700 
F: + 61 7 3860 0701 
For the Americas  
contact: 
GE Aviation 
Customer Services – Clearwater 
P.O. Box 9013, Clearwater, FL 33758 
United States of America 
T: + 1 (727) 539 1631 
F: + 1 (727) 539 0680 
GLOBAL CONTACT:  cs.support@ge.com 
CAGE CODE: K5294 
GE Ref: SCD Revision AL, Ref: 3.7.4.134.1, 134.14, 134.17 
Manual Ref: N/A 
SERVICE BULLETIN 
 
Copyright (2009), GE Aviation Systems Ltd UK 
The information contained in this document is GE Aviation Systems Ltd proprietary in formation and is disclosed in confidence. I t is the 
property of GE Aviation Systems Ltd and shall not be used, discl osed to others or reproduced wit hout the express written consen t of GE 
Aviation Systems Ltd, including, but without limitation, it is  not to be used in the creation, manufacture, development, or der ivation of any 
repairs, modifications, spar e parts, design, or configuration changes or to obtain FAA or any other government or regulatory ap proval to 
do so. If consent is given for reproduction in whole or in part, this notice and the notice set forth on each page of this docu ment shall 
appear in any such reproduction in whole or in part. The informat ion contained in this document ma y also be controlled by U.S. export 
control laws. Unauthorized export or re-export is prohibited. 
 
All technical documentation and information contained herein, with respect to assembly and disassembly, cleaning, inspection methods 
and limits, repair methods and limits, operational limits, life limits and the like, have been developed and approved for use with this 
equipment and parts that have been manufactured and/or approved by GE and that have been maintained in accordance with GE 
technical documentation and recommendations.  GE has no contractual or legal obligation for, nor knowledge of, non-GE-approved parts 
and repairs.  Accordingly, this document is not intended to apply to non-GE-approved parts and repairs. 
 
DESTINATION CONTROL STATEMENT 
The technical data contained in this document (or file) is controlled for export under the Export Administration Regulations (EAR), 15 CFR 
Parts 730-774, ECCN: 9E991. Violations of these laws may be subject to fines and penalties under the Export Administration Act. 
May 08/03 6000ELM-24-614 
Revision No.1.  Nov 09/09 Page1 of 20 
ELECTRICAL POWER – P210 RIGHT POWER MANAGEMENT PANEL 
PANELS 6058ELM1, 6066ELM1 AND 6069ELM1 REQUIRING 
CTU, P210 PASSENGER TELECOMMUNICATION SYSTEM 
AND CABIN FILESERVER/DISK DRIVE UNIT 
WITH FLIGHT DECK SWITCH INTERFACE 
1. PLANNING INFORMATION  
A. Effectivity  
(1) Aircraft affected: Refer to BCAG Service Bulletin Number 777-24-0077 
(2) Unit affected:  P210 Right Power Management Panel 
(3) Part Numbers:  GE Part No.  Boeing Part No.  
60**ELM* S281W601-60** 
Where * equals any number.

### Page 4

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 2  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
 
B. Concurrent Requirements  
This bulletin is one of a number that detail the work required to be embodied on the P210 
panel to accommodate Flight Deck Switch circui try.  This Service Bulletin should be carried 
out after Service Bulletins 6000ELM-24-555, 6000ELM-24-456, 6000ELM-24-545 and 
6000ELM-24-624. 
C. Reason  
(1) Condition Conversion corrects  
The P210 ELMS panel is unable to accommodate the Cabin Telecommunication Unit 
(CTU), the P210 Passenger Telecommunication System and the Cabin File 
Server/Disk Drive Unit as required by the Flight Deck Switch circuitry. 
(2) Extent condition encountered   
Panels 6058ELM1, 6066ELM1 and 6069ELM1. 
(3) Expected benefits of conversion  
The P210 ELMS panel complies with the requirement to accommodate the CTU, 
P210 Passenger Telecommunication System and the Cabin File Server/Disk Drive 
Unit as required by the Flight Deck Switch circuitry. 
D. Description  
This work requires the removal of three busbars and busbar connections at Circuit Breakers 
C6 (C23430 – CTU), D3/E5 (C23432/C23434 P210 Passenger Telecommunication System) 
and E7 (C23454 – Cabin File Server/Disk Drive Unit). These four Circuit Breakers are then 
connected to another supply via the contacts of an existing relay K24302. Three new busbars 
are fitted and the busbar connections removed earlier are then reconnected. One new wire 
and six new Flexible Bus cables are introduced as a result of this work. Figures 2 to 4 refer.   
E. Compliance  
ELMS P210 Right Power Management Panels as defined in BCAG Service Bulletin Number 
777-24-0077. 
F. Approval  
The repairs and modifications herein comply with the applicable regulations and are on record 
with the supplier as FAA-approved, as well as EASA/JAA approved. 
G. Manpower  
The incorporation of this work will take approximately 4 man hours excluding testing.

### Page 5

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 3  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
 
H. Material and Availability  
The conversion kit, part number 6000ELM-24-614, is  currently available and is rechargeable. 
For details of the contents of the conversion kit, refer to paragraph 3 of this Service Bulletin.  
For details of the price and availability of the conversion kit, refer to the supplementary page of 
this Service Bulletin.  For further information contact either: 
GE Aviation, 
Spares & Repairs Dept. CSD1, 
Bishops Cleeve, 
Cheltenham, 
Glos. GL52 8SF, 
England 
or GE Aviation, 
Customer Services - Clearwater, 
P.O. Box 9013, 
Clearwater, 
FL 33758, 
United States of America 
I. Tooling Required  
In addition to standard airplane electrical wiring tools the following specialist tooling (or 
equivalent) is required: 
(1) Crimp Plier, Part No. M22520/1-01. 
(2) Positioner, Part No. M22520/1-02. 
(3) Crimp Plier, Part No. AMP 525692. 
(4) Insertion/Extraction Tool, Part No. M81969/14-04 (Yellow/White). 
J. Weight and Balance  
None. 
K. Electrical Load Data  
Refer to BCAG Service Bulletin Number 777-24-0077. 
L. Reference  
(1) BCAG Aircraft Maintenance Manual. 
(2) BCAG Service Bulletin Number 777-24-0077. 
M. Other Publications Affected  
BCAG Aircraft Maintenance Manual.

### Page 6 (OCR)

SERVICE BULLETIN
RIGHT POWER MANAGEMENT
PANEL, P210
SEE A  SEE
MAIN EQUIPMENT CENTER
ACCESS DOOR, 117AL
FWDE
MAIN EQUIPMENT CENTER
(A
Airplane
Connectors
B)  P210 Right Power Management Panel
(Left Hand Door & EU Door not illustrated)
Figure 1
May 08/03  6000ELM-24-614
Revision 1. Nov 09/09  Page 4
GE Proprietary Information - subject to the restrictions on the cover or first page

### Page 7 (OCR)

SERVICE BULLETIN
- C28403
PHASE A
}-c30408
PHASE B
Applicable to  6069ELM1 panels only  - c35423  3-c28716  }-C26415  -CTÉÁ00  PHASE C
3B c23310  121314  3723309  3. 02$303
- 29-11-12  115V AC Right Section 1 Bus  Before Conversion  Figure 2
R421 / 1  DM24405C
W3202-1002-22•  - W3202-1049-22•  M24405  DM24405A TYPE A
TB407/2  M24403  ELMS  P210  ELECTRONIC UNIT
May 08/03  6000ELM-24-614
Revision 1. Nov 09/09  Page 5
GE Proprietary Information - subject to the restrictions on the cover or first page

### Page 8 (OCR)

SERVICE BULLETIN
PHASE A
PHASE B
6069ELM1 panels only  }r- c254031  →-C7·å00  3- c35423  3-C26415
Applicable to  PHASE C
· 23310  c2ŸŠ14  · c23309  ·c25303
W3205-0100-8  W3205-0098-8  29-11-12  115V AC Right Section 1 Bus  After Conversion  Figure 3
TB421/1  TB407/2  CONDITIONING CARD  DM24405C  DP 415  -W3204-0592-22
W3202-1002-22  - W3202-1049-22  DM24405A TYPE
TB407/2  W3202-0134-22  M24403  P210 ELMS  ELECTRONIC UNIT
D 21003
May 08/03  6000ELM-24-614
Revision 1. Nov 09/09  Page 6
GE Proprietary Information - subject to the restrictions on the cover or first page

### Page 9

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 7  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
 
CTU, P210 Passenger Telecommunication System 
and Cabin File Server/Disk Drive Unit 
Flight Deck Switch Power Distribution from Relay K24302 
After Conversion 
Figure 4

### Page 10 (OCR)

ув)
SERVICE BULLETIN
10-position Relay Bracket Assembly
Relay Base®
DK24302
Land
Relay
K24302
K24013
000
Cabinet Assembly - Typical Layout
Figure 5
May 08/03  6000ELM-24-614
Revision 1. Nov 09/09  Page 8
GE Proprietary Information - subject to the restrictions on the cover or first page

### Page 11

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 9  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
2. ACCOMPLISHMENT INSTRUCTIONS  
WARNINGS: FAILURE TO FOLLOW THE APPLICABLE INSTRUCTIONS GIVEN IN THIS 
PUBLICATION AS AMENDED BY GE REVISIONS MAY ENDANGER SAFETY. 
THIS DOCUMENT ONLY COVERS IMPLEMENTATION OF THE REFERENCED 
CHANGE.  IT DOES NOT ADDRESS PRE OR POST-IMPLEMENTATION TASKS. 
TO ENSURE THE SAFETY OF PERSONNEL IMPLEMENTING THE WORK, 
REFERENCE MUST BE MADE TO ALL INSTRUCTIONS REGARDING SAFETY 
RELATED PROCEDURES (E.G. POWER DOWN) DETAILED IN THE AIRCRAFT 
MAINTENANCE MANUAL. 
NOTES: 1. During the embodiment of this Service Bulletin any Anti-Abrasion Tape (part 
number 1756-746), Lacing Tape or Heatshrink (part number 1837-1909-02), 
which has to be removed is to be replaced from customers own resources. 
2. During the embodiment of this Service Bulletin most labels that are to be fitted 
must be positioned in the same location as the old label they are replacing, the 
old label must be entirely removed.  Ho wever, labels containing Circuit Breaker 
titles and/or Bus information may be placed over the existing label if necessary. 
3. In order to improve access to specified connectors it is acceptable to disconnect 
other connectors or remove hardware as necessary.  Operators must ensure that 
any such disturbances are noted and returned to their original state before this 
work is completed. 
A. Embodiment Instructions  
(1) Refer to Figure 1 and on the P210 Right Power Management Panel proceed as 
follows: 
(a) Release the 2-off fasteners on the Right Hand (RH) Door. Open and engage 
the RH Door stay. 
(b) Release the 4-off fasteners on the Left Hand (LH) Door. Open and engage 
the LH Door stay. 
(2) Unlock the 2-off captive screws securing the LH Relay Panel and lower to the 
horizontal position.  Repeat this procedure for the RH Relay Panel. 
(3) On the LH Door, locate the 5-tag Busbar in row D linking Circuit Breakers D1 to D5. 
(4) Refer to Figure 2 and remove the CB Screw Assemblies securing the 5-tag Busbar to 
Circuit Breakers D1 to D5.  Note the position of the Flexible Cable Assembly that links 
Circuit Breaker D1 to A2 terminal B1. Retain the CB Screw Assemblies and also 
retain the 5-tag Busbar.

### Page 12

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 10  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
(5) From the conversion kit, select the following items: 
(a) 2-tag, 60 Amp Busbar, part no. 80-268-208-02. 
(b) 5-inch 60 Amp Flexible Cable Assembly, part number 40-761-146-05. 
(c) Yellow Heatshrink Sleeve, part number 1837-1907-02. 
(6) Refer to Figure 3 and fit the new 2-tag Busbar into position over terminal 1 of Circuit 
Breakers D1 to D2.  Secure in position using two of the retained CB Screw 
Assemblies. Reconnect the Flexible Cable A ssembly linking Circuit Breaker D1 to A2 
terminal B1.  
CAUTION: DURING THIS CONVERSION ALL CIRCUIT BREAKER TERMINAL SCREWS 
MUST BE TORQUE LOADED TO BETWEEN 13.50 AND 16.50 LBF INCHES (1.5 
AND 1.8 Nm). 
(7) Prepare the 60 Amp Cable Assembly as follows: 
(a) Cut two lengths of Yellow Heatshrink Sleeve, each approximately ½ inch 
long. 
(b) Refer to Figure 6 below, then fit a Yellow Heatshrink Sleeve to each end of 
the new Flexible Cable Assembly for Phase B identification. 
(c) Using a heatgun, apply direct heat to the sleeves until secure . 
 
Cable Assembly 
 
Figure 6 
(8) Return to the LH door and refer to Figure 3.  Using the retained CB Screw 
Assemblies, connect the new 5-inch Flexible Cable Assembly as follows: 
Cable Assembly to be fitted (LH Door Assembly) 
From 
Circuit Breaker 
To 
Circuit Breaker Length Sleeve Colour 
D2 terminal 1 D5 terminal 1 5 inches Yellow

### Page 13

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 11  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
 
(9) On the rear of the LH Door, locate the 6-tag Busbar in row C linking Circuit Breakers 
C1 to C6. 
(10) Refer to Figure 2 and remove the CB Screw Assemblies securing the 6-tag Busbar.  
Note the position of the Flexible Cable Assembly that links Circuit Breaker C1 to A2 
terminal A1.  Retain the CB Screw Assemblies and discard the 6-tag Busbar. 
(11) Locate the 5-tag Busbar retained earlier and carefully remove and discard any 
heatshrink fitted to any of the busbar lugs. 
(12) Refer to Figure 3 and fit the retained 5-tag Busbar into position over terminal 1 of 
Circuit Breakers C1 to C5.  Secure in position using five of the retained CB Screw 
Assemblies.  Reconnect the Flexible Cable Assembly linking Circuit Breaker C1 to A2 
terminal A1. 
CAUTION: DURING THIS CONVERSION ALL CIRCUIT BREAKER TERMINAL SCREWS 
MUST BE TORQUE LOADED TO BETWEEN 13.50 AND 16.50 LBF INCHES (1.5 
AND 1.8 Nm). 
(13) 6069ELM1 Panels only : On the LH Door, locate the 8-tag Busbar in row E linking 
Circuit Breakers E1 to E8. 
(14) 6058ELM1 and 6066ELM1 Panels only : On the LH Door, locate the 7-tag Busbar in 
row E linking Circuit Breakers E1 to E7. 
(15) Refer to Figure 2 and remove the CB Screw Assemblies securing the Busbar to 
Circuit Breakers E1 to E7 or E8 as applicable.  Note the position of the Flexible Cable 
Assembly that links Circuit Breaker E1 to  A2 terminal C1. Retain the CB Screw 
Assemblies and discard the Busbar. 
(16)  From the conversion kit, select the following items: 
(a) 4-tag, 60 Amp Busbar, part no. 80-268-208-04. 
(b) 6058ELM1 and 6066ELM1 Panels only : 1-off 5-inch 60 Amp Flexible Cable 
Assembly, part number 40-761-146-05. 
(c) 6069ELM1 Panels only : 2-off 5-inch 60 Amp Flexible Cable Assemblies, part 
number 40-761-146-05. 
(d) Blue Heatshrink Sleeve, part number 1837-1907-12. 
(17) Refer to Figure 3 and fit the new 4-tag Busbar into position over terminal 1 of Circuit 
Breakers E1 to E4.  Secure in position using four of the retained CB Screw 
Assemblies. Reconnect the Flexible Cable A ssembly linking Circuit Breaker E1 to A2 
terminal C1. 
CAUTION: DURING THIS CONVERSION ALL CIRCUIT BREAKER TERMINAL SCREWS MUST BE 
TORQUE LOADED TO BETWEEN 13.50 AND 16.50 LBF INCHES (1.5 AND 1.8 Nm).

### Page 14

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 12  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
(18) Prepare each 60 Amp Cable Assembly as follows as applicable: 
(a) Cut two lengths of Blue Heatshrink Sleeve, each approximately ½ inch long. 
(b) Refer to Figure 6, then fit a Blue Heatshrink Sleeve to each end of the new 
Flexible Cable Assembly for Phase C identification. 
(c) Using a heatgun, apply direct heat to the sleeves until secure . 
(d) 6069ELM1 Panels only : Repeat the procedure in paragraphs (a), (b) and (c) 
above on the remaining new Flexible Cable Assembly. 
(19) Return to the LH door and refer to Figure 3.  Using the retained CB Screw Assemblies 
proceed as follows: 
(a) 6058ELM1 and 6066ELM1 Panels only : Connect the new 5-inch Flexible 
Cable Assembly as follows: 
Cable Assembly to be fitted (LH Door Assembly) 
From 
Circuit Breaker 
To 
Circuit Breaker Length Sleeve Colour 
E4 terminal 1 E6 terminal 1 5 inches Blue 
(b) 6069ELM1 Panels only : Connect the two new 5-inch Flexible Cable 
Assemblies as follows: 
Cable Assemblies to be fitted (LH Door Assembly) 
From 
Circuit Breaker 
To 
Circuit Breaker Length Sleeve Colour 
E4 terminal 1 E6 terminal 1 5 inches Blue 
E6 terminal 1 E8 terminal 1 5 inches Blue 
CAUTION: DURING THIS CONVERSION ALL CIRCUIT BREAKER TERMINAL SCREWS MUST BE 
TORQUE LOADED TO BETWEEN 13.50 AND 16.50 LBF INCHES (1.5 AND 1.8 Nm). 
(20) From the conversion kit, select the following items: 
(a) 12 AWG wire marked W3235-0084-12, part no. 1344-1989-01. 
(b) 1-off, 12 AWG Ring Tongue Tag, part no. 40-716-1164. 
(c) 2-off, 7-inch 60 Amp Flexible Cable Assembly, part number 40-761-146-09. 
(d) 1-off, 5-inch 60 Amp Flexible Cable Assembly, part number 40-761-146-05 
(e) Red Heatshrink Sleeve, part number 1837-1907-07.

### Page 15

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 13  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
 
(21) Prepare the three 60 Amp Cable Assemblies as follows: 
(a) Cut six lengths of Red Heatshrink Sleeve, each approximately ½ inch long. 
(b) Refer to Figure 6 then fit a Red H eatshrink Sleeve to each end of the new 
Flexible Cable Assemblies for Phase A identification. 
(c) Using a heatgun, apply direct heat to the sleeves until secure . 
(22) Prepare one end of the new wire and proceed as follows: 
(a) Using Crimp Plier AMP 525692, crimp a 12 AWG Ring Tongue Tag at the 
prepared end of the wire marked W3235-0084-12. 
(23) Return to the LH door and refer to Figure 4.  Using the retained CB Screw 
Assemblies, connect the wires and the Flexible Cable Assemblies as follows: 
Circuit Breaker C23430 (C6) 
Wire marked Terminal 
W3235-0084-12 
7-inch Flexible Cable Assembly with Red 
Phase A Identification 
1 
CAUTION: DURING THIS CONVERSION ALL CIRCUIT BREAKER TERMINAL SCREWS MUST BE 
TORQUE LOADED TO BETWEEN 13.50 AND 16.50 LBF INCHES (1.5 AND 1.8 Nm). 
(24) Refer to Figure 4 and using the CB Screw Assemblies retained earlier, connect the 
free end of the 7-inch Flexible Cable Assembly, then connect the remaining new 7-
inch and 5-inch Flexible Cable Assemblies as detailed below: 
Cable Assembly to be fitted (RH Door Assembly) 
From 
Circuit Breaker 
To 
Circuit Breaker Length Sleeve Colour 
C6 terminal 1 D3 terminal 1 7 inches Red 
D3 terminal 1 E5 terminal 1 7 inches Red 
E5 terminal 1 E7 terminal 1 5 inches Red 
CAUTION: DURING THIS CONVERSION ALL CIRCUIT BREAKER TERMINAL SCREWS MUST BE 
TORQUE LOADED TO BETWEEN 13.50 AND 16.50 LBF INCHES (1.5 AND 1.8 Nm).

### Page 16

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 14  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
 
(25) Return to the LH door Circuit Breaker C6 with reference to Figure 4. Route wire 
marked W3235-0084-12 to Relay K24302 on the 10-position Relay Bracket Assembly 
noting that the wire must be: 
(a) Contained within the YELLOW cableform. 
(b) Routed INSIDE cable clamps, abr asion resistant tape and lacing tape. 
(c) Installed so as not to create unacceptable crossovers with existing wires in 
the cableform. 
NOTE: It will be necessary to loosen the cable clamp arrangements to allow the new wiring to 
be fed through. 
(d) After routing is complete cut the wire to a suitable length to be terminated into 
Relay Base DK24302.  Prepare the end of the wire. 
(26) On the 10-position Relay Bracket Assembly, remove and retain Relay K24302, fixing 
screws, split washers and plain washers. 
(27) From the conversion kit, select the following item: 
(a) 1-off Size 12 Crimp Contact, part no. 30-867-6709-05U. 
(28) Using Crimp Plier M22520/1-01, wire size setting 8, together with Positioner 
M22520/1-02 set to Yellow position, crimp a Size 12 Crimp Contact at the prepared 
end of the routed wire marked W3235-0084-12. 
(29) Refer to Figure 4 and, using Insertion Tool M81969/14-04 (Yellow end), install the 
prepared wire as detailed below: 
Relay Base DK24302 
Wire marked Into Contact 
W3235-0084-12 C1 
(30) From the conversion kit, select the following items: 
(a) Label Row C, part no. ELM812-24C. 
(b) Label Row C, part no. ELM812-25C. 
(c) Label Row D, part no. ELM812-63D. 
(d) Label Row D, part no. ELM812-64D. 
(e) Label Row E, part no. ELM812-35E.  
(f) Label Row E, part no. ELM812-40E.

### Page 17

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 15  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
(31) Panel 6069ELM1 only . Fit Label part no. ELM812-24C over the existing row C label 
on the LH Door Assembly. 
(32) Panels 6066ELM1 and 6058ELM1 only . Fit Label part no. ELM812-25C over the 
existing row C label on the LH Door Assembly. 
(33) Panels 6069ELM1 and 6066ELM1 only . Fit Label part no. ELM812-63D over the 
existing row D label on the LH Door Assembly. 
(34) Panel 6058ELM1 only . Fit Label part no. ELM812-64D over the existing row D label 
on the LH Door Assembly. 
(35) Panels 6066ELM1 and 6058ELM1 only . Fit Label part no. ELM812-35E over the 
existing row E label on the LH Door Assembly. 
(36) Panel 6069ELM1 only . Fit Label part no. ELM812-40E over the existing row E label 
on the LH Door Assembly. 
NOTE: Operators of 6058ELM1 or 6069ELM1 panels w ho carried out the work detailed above in 
paragraphs (30) through (36) from the original document (i.e. pre revision 1) will need to carry 
out the following procedures in paragraphs (37) and (38) to return their panels to the correct 
standard. 
(37) Panels 6058ELM1 only . Proceed as follows on the LH Door Assembly: 
(a) Fit Label part no. ELM812-25C over the existing row C label (ELM812-24C). 
(b) Fit Label part no. ELM812-64D over the existing row D label (ELM812-63D). 
(c) Fit Label part no. ELM812-35E over the existing row E label (ELM812-36E). 
(38) Panels 6069ELM1 only . Proceed as follows on the LH Door Assembly: 
(a) Fit Label part no. ELM812-24C over the existing row C label (ELM812-25C). 
(b) Fit Label part no. ELM812-63D over the existing row D label (ELM812-64D). 
(c) Fit Label part no. ELM812-40E over the existing row E label (ELM812-35E). 
(39) From the conversion kit select and fit as necessary: 
(a) DK24302 Mate-with label, part number ELM851-1. 
(40) With reference to Figures 3 to 4 (as applicable) and the table detailed below, carry out 
the following continuity checks: 
(a) Verify there is high resistance (i.e. a resistance greater than 2k Ω) between 
the following terminals/contacts, with the specified Circuit Breaker open. 
Continued overleaf/

### Page 18

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 16  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
\Continued 
(b) Verify there is continuity (i.e. a resistance less than 1 Ω) between the following 
terminals/contacts, with the specified Circuit Breaker closed. 
Circuit Breaker 
Open/Closed From To 
C6 C6 terminal 2 DK24302 contact C1 
D3 D3 terminal 2 DK24302 contact C1 
E5 E5 terminal 2 DK24302 contact C1 
E7 E7 terminal 2 DK24302 contact C1 
(c) Verify there is continuity (i.e. a resistance less than 1 Ω) between the following 
terminals/contacts as applicable: 
From To 
C5 terminal 1 A2 terminal A1 
D5 terminal 1 A2 terminal B1 
(6069ELM1 Panels only) 
E8 terminal 1 
(6058ELM1 and 6066ELM1 Panels only) 
E6 terminal 1 
A2 terminal C1 
(41) Locate the two Relays together with the fixing screws, split washers and plain 
washers retained earlier.  Refer to Figure 7 and proceed as follows: 
(a) Check the required orientation and then fit the Relay K24302 onto Relay Base 
DK24302. 
(b) Torque load the relay fixing screws to between 3.0 and 5.0 lbf inches (0.3 and 
0.5 Nm). 
 
Relay Base and Relay Fixings 
Figure 7

### Page 19

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 17  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
 
(42) From the conversion kit select the following item: 
(a) Work Carried Out Label marked S.B. 6000ELM-24-614 , part number 
ELM139-13. 
(43) Locate the Flight Deck Switch Work Carried Out Record Card which should be fixed 
prominently to the Cabinet frame. Fit the new Work Carried Out Label  in the next 
vacant space below any other label(s) that may have been fixed to the card as a result 
of previous work. 
NOTE: Operators should note that if, after the completion of this work, they plan to 
incorporate another Flight Deck Switch (FDS) Service Bulletin. They may ignore 
the following paragraphs requiring them to secure those parts of the panel, which 
have been disturbed. This is intended to avoid having to secure, for example, a 
cableform that may subsequently be used in another FDS Service Bulletin. 
However, this must be done at the tradesman’s discretion with full consideration 
given to the security of certain connectors/nuts/screws and the possibility that 
they may be missed when the final FDS Service Bulletin is incorporated. 
(44) Ensure that: 
(a) All disturbed cable clamp pillar screws are torque loaded to between 35.1 and 
42.9 lbf inches (4.0 and 4.8 Nm). 
(b) All disturbed circuit breakers are closed. 
(c) All disturbed nuts and screws are tightened to relevant torque settings. 
(d) All disturbed connectors are reassembled as necessary and reconnected. 
(e) All cables and splices are securely tied-in to suitable positions. 
(f) A full internal cabinet visual inspection is carried out and all debris is 
removed. 
(45) Return the LH Relay Tray to the upright position and secure the 2-off fasteners. 
(46) Return the RH Relay Tray to the upright position and secure the 2-off fasteners. 
(47) Disengage the RH Door Stay and close the RH Door.  Secure the 2-off fasteners on 
the RH Door. 
(48) Disengage the LH Door Stay and close the LH Door.  Secure the 4-off fasteners on 
the LH Door. 
(49) Apply 'tamperproof' inspection seals to the LH and RH Doors as required from 
customers own resources.

### Page 20

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 18  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
3. MATERIAL INFORMATION  
WARNING: ONLY SPARES AND COMPONENTS SPECIFIED BY GE SHOULD BE USED. 
NOTE: 
ORDERING 
Certain spare parts listed in the Service Bulletin are manufactured by other contractors and have the 
manufacturer's number or British Standards reference quoted in addition to the part number under 
which GE Aviation Systems Ltd supply. 
When ordering through Aviall please quote the GE part number, the other manufacturer's number or 
British Standards reference and the Code number of the unit, on all orders or enquiries. 
When ordering from other manufacturers please quote the manufacturer's number and/or British 
Standards reference only. 
A. Conversion kit 6000ELM-24-614 consists of the following parts:-  
New 
Part Number Qty Key Word Old Part Number Disposition Instruction 
ELM139-13 1 
Work Carried Out 
Label marked 
S.B. 6000ELM-24-614 
- - 
ELM812-24C 1 Label Row C Panel 6069ELM1 only - - 
ELM812-25C 1 Label Row C Panels 6066ELM1 & 6058ELM1 only - - 
ELM812-63D 1 Label Row D Panels 6069ELM1 & 6066ELM1 only  - - 
ELM812-64D 1 Label Row D Panel 6058ELM1 only - - 
ELM812-35E 1 Label Row E Panels 6066ELM1 & 6058ELM1 only - - 
ELM812-40E 1 Label Row E Panel 6069ELM1 only - - 
ELM851-1 1 DK24302 Mate-With label - - 
30-867-6709-05U 1 Size 12 Crimp Contact - - 
40-716-1164 1 12 AWG Ring Tongue Tag - - 
 
Continued overleaf/

### Page 21

.  SERVICE BULLETIN  .  
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 19  
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
 
/Continued 
 
New 
Part Number Qty Key Word Old Part Number Disposition Instruction 
40-761-146-05 4 5 inch 60 Amp Flexible Cable Assembly  - - 
40-761-146-09 2 7 inch 60 Amp Flexible Cable Assembly  - - 
80-268-208-02 1 2-tag, 60 Amp Busbar - - 
80-268-208-04 1 4-tag, 60 Amp Busbar - - 
1344-1989-01 4 m 12 AWG wire marked W3235-0084-12 - - 
1837-1907-02 0.5 m Yellow Heatshrink Sleeve - - 
1837-1907-07 0.5 m Red Heatshrink Sleeve - - 
1837-1907-12 0.5 m Blue Heatshrink Sleeve - -

### Page 22

GEK 115335
For Europe, Africa, India and  
Middle East contact: 
GE Aviation 
Customer Services - Cheltenham 
Bishops Cleeve, Cheltenham, 
Glos GL52 8SF, United Kingdom 
T: + 44 (0)1242 673355 
F: + 44 (0)1242 669165 
For Asia, Australasia and the Pacific 
contact: 
GE Aviation 
3 Hakea Street, 
Brisbane Airport, QLD4007, 
Australia 
T: + 61 7 3860 0700 
F: + 61 7 3860 0701 
For the Americas  
contact: 
GE Aviation 
Customer Services – Clearwater 
P.O. Box 9013, Clearwater, FL 33758 
United States of America 
T: + 1 (727) 539 1631 
F: + 1 (727) 539 0680 
GLOBAL CONTACT:  cs.support@ge.com 
CAGE CODE: K5294 
GE Ref: SCD Revision AL, Ref: 3.7.4.134.1, 134.14, 134.17 
Manual Ref: N/A 
SERVICE BULLETIN 
 
May 08/03 6000ELM-24-614 
Revision 1.  Nov 09/09 Page 20 of 20 
 
GE Proprietary Information – subject to the restrictions on the cover or first page 
 
SUPPLEMENT - PRICE AND AVAILABILITY 
 
ELECTRICAL POWER – P210 RIGHT POWER MANAGEMENT PANEL 
 
PANELS 6058ELM1, 6066ELM1 AND 6069ELM1 REQUIRING  
 
CTU, P210 PASSENGER TELECOMMUNICATION SYSTEM  
AND CABIN FILESERVER/DISK DRIVE UNIT  
WITH FLIGHT DECK SWITCH INTERFACE 
 
 
This is a technical document not a quotation; pric es and delivery times given are in good faith without 
engagement. 
 
Conversion kit part number 6000ELM-24-614 comprising the items listed in paragraph 3 of this bulletin, will be 
available for shipment within 270 days from receipt of order at a price which will be quoted upon application. 
This price may be subject to change without notice. 
 
All orders should specify the kit part number and be addressed to: 
Aviall Services Inc. 
2750 Regent Blv'd 
Dallas, TX. 75261-9048 
U.S.A. 
North America Phone 1-800-284-2551 
North America Fax. 1-800-329-2842 
International Phone 1-972-586-1985 
International Fax. 1-972-586-1983

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.