# Goodrich Service Bulletin 80232190-24-01

## Copies (2)

Copies the FAA filed in AD dockets on regulations.gov, newest revision first. A newer revision may exist.

- No revision named ("U.S. DOT/FAA - Service Bulletin (Goodrich - A PT.)"), 11 pages: PDF https://openairdocs.org/files/sha256/86/46/864613fcaf07162acf18fbd1d1b561ec9cdbed32629d6b22032b9a49b5aee6fd; text https://openairdocs.org/service-documents/goodrich/sb-80232190-24-01/file/864613fcaf07.md. Rights: © Goodrich. Filed by the FAA in regulations.gov docket FAA-2012-0265; AD 2012-12-18 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- No revision named ("U.S. DOT/FAA - Service Bulletin (Goodrich - G, A PT.)"), 11 pages: PDF https://openairdocs.org/files/sha256/4d/86/4d86ac087bfdc9a08dc2de3e9cea3a04887e071808d5aceb6e580588bfbf6cd5; text https://openairdocs.org/service-documents/goodrich/sb-80232190-24-01/file/4d86ac087bfd.md. Rights: © Goodrich. Filed by the FAA in regulations.gov docket FAA-2012-0265; AD 2012-12-18 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Goodrich](https://openairdocs.org/service-documents/goodrich.md)
- Type: Service bulletin (Service Bulletin)
- Number: 80232190-24-01
- Page: https://openairdocs.org/service-documents/goodrich/sb-80232190-24-01

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2012-12-18](https://openairdocs.org/ad/2012-12-18.md), effective Jul 30, 2012: No revision named

Also cited in [1 proposed AD](https://openairdocs.org/service-documents/goodrich/sb-80232190-24-01/proposed.md).

## Text (11 pages)

No revision named, the newest copy. Rights: © Goodrich. Filed by the FAA in regulations.gov docket FAA-2012-0265; AD 2012-12-18 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. This text is OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232190-24-01
Goodrich Power Systems
Westfield Road
Pitstone LU7 9GT England
0044 1296 663000
SERVICE BULLETIN
STANDARD
ELECTRICAL POWER - PDCU A PT. NO. 80232190, 80231869/S5, 80231869/S6 AND
80231869/S7 INSPECTION/CHECK OF THE TRANSIENT SUPPRESSION DIODES
INSTALLED
INITIAL ISSUE
OF
SERVICE BULLETIN
80232190-24-01
AIRCRAFT APPLICABILITY DASSAULT FALCON 7X
1.  Instructions
A. The Service Bulletin was written under EASA Approval No. UK.145.00858.
B. The technical content of this document is approved under the authority of DOA No. EASA.21J.051.
Copyright in this Service Bulletin and associated documents and drawings belongs to Goodrich Power Systems and all rights are reserved.
No reproduction of all or part of this Service Bulletin shall be made without the prior written consent of Goodrich Power Systems.
This document contains information that may be confidential and its disclosure to others requires the written consent of Goodrich Power
Systems.

### Page 2 (OCR)

GooDRICH
SERVICE BULLETIN
Number 80232190-24-01
INTENTIONALLY BLANK

### Page 3 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232190-24-01
Planning Information
A. Effectivity
(1) This Service Bulletin (SB) applies to the Goodrich Corporation PDCU A Cards Pt. No. 80232190,
80231869/S5 80231869/S6 and 80231869/S7 installed in the Left and Right Primary Power
Distribution Box (PPDB), installed on the Falcon 7X aircraft.
B. Concurrent Requirements
(1) None.
C. Reason
(1) Dassault Aviation has performed an analysis of aircraft-level effects associated with degradation of
33 Volt Transient Voltage Suppression (TVS) Diode in the Primary Distribution Control Unit (PDCU)
and Generator Control Unit (GU) printed circuit board assemblies.
D. Description
(1) The TVS Diodes have been categorised based on the severity of the effect. This SB gives the
procedures necessary to identify the degradation of "Priority 1 and 2" TVS Diodes.
E. Compliance recommendation
(1) At the next removal of a PDCU A card.
F. Approval
(1) The technical content of this document is approved under the authority of DOA No. EASA.21J.051.
G. Manpower
(1) 0.25 Man hours
H. Weight and Balance
(1) None.
Electrical Load Data
(1) None.
J. Software Accomplishment Summary
(1) Not applicable
K. References
(1) This SB was written using Goodrich Engineering Report PG0900400ED and rework drgs
80232007 & 80232214 as source data.
Other Publications Affected
Goodrich ACMM for the PDCU-A CARD ASSEMBLY Part No. 80232190, ATA No. 24-61-08
will be revised to include the data contained in this SB.
Goodrich CMM for the Left PPDB, Part No. SW02101, ATA No. 24-61-01 will be revised to
reference the data contained in this SB
Goodrich CMM for the Right PPDB, Part No. SW02201, ATA No. 24-61-02 will be revised to
reference the data contained in this SB
M. Interchangeability or Intermixability of Parts
(1) Not applicable
Initial Issue  : Aug 13/09  80232190-24-01
Revision Date: Aug 13/09
©: Goodrich Power Systems - 2009 All rights reserved:  Page 1 of 9

### Page 4 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232190-24-01
2.  Material Information
A. Material - Price and Availability
(1) Not Applicable.
B.  Industry Support Program
(1) Not Applicable.
C.  Material Necessary for each Component/Engine
(1) Not Applicable.
D. Spare Parts Availability
(1) Not Applicable.
E. Re-identified Parts
(1) None.
F.  Tooling - Price and Availability
(1) The tools given below are necessary for this SB and are to be procured from the sources given.
Prices and lead times for Goodrich tools are available on request.
Qty  Part Number  Source  Keyword
1  Commercially Available  ESD Surface mat and
wrist band
1  TE2-0658  Goodrich Power  Falcon multi-channel
Systems  transorb tester (33V)
1  Commercially Available  Power supply 48V D.C.
2  Locally Made  Ground lead with 4mm
plug terminations
2  Commercially Available  Crocodile clip
3.  Accomplishment Instructions
A. General
CAUTION: THE SPB CONTAINS ITEMS THAT ARE ELECTROSTATIC-DISCHARGE SENSITIVE
(ESDS). OBEY APPROVED INDUSTRY PRECAUTIONS WHEN YOU TOUCH, REMOVE
OR INSTALL PARTS. DAMAGE CAN OCCUR FROM ELECTROSTATIC DISCHARGE.
NOTE: This SB is intended for use on a PDCU A that is removed from the PPDB and off the aircraft.
(1) Place the PDCU A card on the ESD mat.
(2) Connect a ground lead to the ground socket of the test-set and a suitable earth point.
(3)  Connect the DC plug from the Power Supply Unit (PSU) to the 48 volts socket on the side of the
test-set.
(4)  Connect mains lead from the PSU to an applicable a.c. outlet and apply mains power.
Initial Issue  : Aug 13/09  80232190-24-01
Revision Date : Aug 13/09
©: Goodrich Power Systems - 2009 All rights reserved.  Page 2 of 9

### Page 5 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232190-24-01
(5) Push the "TEST" button on the test-set, make sure the 40 RED LEDs illuminate.
NOTE: If, the RED LEDs do not illuminate the test set is damaged.
B.  Procedure
(1) Plug the board into the PDCU A connector on the test-set (Ref. Fig. 1).
NOTE: The top side of the board (the side with the main connector) must face you.
(2)  Connect a ground lead to the socket "GROUND" on the test-set. Use a crocodile clip and connect
the ground lead to the thermal plane of the PDCU A card (Ref. Fig. 2).
(3) Record serial number of the PDCU A card and the test-set on the Results sheet.
(4) Push the "TEST" button on the test-set, record the status of all the LEDs on the Result Sheet
Appendix 1.
NOTE: This is to collect data for possible future enhancements.
(5) Release the test button.
(6)  Push the "TEST" button on the test-set, and make sure the circuit LEDs listed (Ref. Table 1) are all
GREEN.
Table 1 LED Pass PDCU A
Circuit No.  Function  RED LED  GREEN LED  Result
BUS TIE MAN  OFF  ON  PASS
2  BTC1 A ST  OFF  ON  PASS
3  GLC3 A ST  OFF  ON  PASS
4  GLC2 A ST  OFF  ON  PASS
5  GLC1 A ST  OFF  ON  PASS
14  BTC2 A ST  OFF  ON  PASS
17  STBY PUMP ON  OFF  ON  PASS
18  BTC3 A ST  OFF  ON  PASS
19  HSCB_SBEP ON  OFF  ON  PASS
(7) Release the test button.
(8)  If, a RED LED is ON or a GREEN LED is OFF (Ref. Table 1), the PDCU A card must be returned to
Goodrich Power systems.
C. Completion
(1) Disconnect and remove the ground lead and crocodile clip from the thermal plane of the PDCU A
card.
(2) Remove the PDCU A card from the test-set.
(3) Remove a.c. mains power and disconnect the PSU from the a.c. outlet..
(4) Disconnect the PSU from the 48 volts socket on the side of the test-set.
Initial Issue  : Aug 13/09  80232190-24-01
Revision Date : Aug 13/09
©: Goodrich Power Systems - 2009 All rights reserved.  Page 3 of 9

### Page 6 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232190-24-01
(5) Remove the ground lead from the ground socket of the test-set and the earth point.
GCU
GROUND  PDCU B
PDCU A
TEST
07  09
POGUA
POCU B  NEARST
ucu
•0  •0  •0  •0  •0  00  •0  00
11  12
POCO A  BTC3,4.57
SOL TED
•0  •0  •0  00  •0  •  •0  00  •0
21  37
POICO A
00  •0  •0  00  •0  •0
31
POGUA
POCU R
00  00  •0  00  00  00  00  00  •0
D7X_SB_2401_0002_01_
Test set TE2-0658
Figure 1
Initial Issue  : Aug 13/09  80232190-24-01
Revision Date : Aug 13/09
©: Goodrich Power Systems - 2009 All rights reserved.  Page 4 of 9

### Page 7 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232190-24-01
ESD plane
10 00g0  10000
10000  800 80
êоệoЄ
0000
Çuëc
D7X_SB_2401_0001_01
PDCU A
Figure 2
Initial Issue  : Aug 13/09  80232190-24-01
Revision Date : Aug 13/09
©: Goodrich Power Systems - 2009 All rights reserved.  Page 5 of 9

### Page 8 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232190-24-01
INTENTIONALLY BLANK
Initial Issue  tevision Date : Aug 13/09  Aug 13/0  80232190-24-01
Page 6 of 9
©: Goodrich Power Systems - 2009 All rights reserved.

### Page 9 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232190-24-01
Appendix 1
A.  Complete the Results Table.
NOTE: * Delete as necessary.
Table 2 Results Table
Board type  Serial No.  TE2-0658, Serial No.
Circuit No.  Function  RED LED  GREEN LED
PDCU A: BUS_TIE_MAN  ON* / OFF*  ON* / OFF*
PDCU B: GLC4_B_ST
2  PDCU A: BTC1_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: GLC3_B_ST
GCU: STAR
PDCU A: GLC3_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: GALLEY_NOT_SHED
GCU: TRIP
4  PDCU A: GLC2_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: BTC1_B_ST
GCU: READY2LOADA
5  PDCU A: GLC1_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: CABIN_NOT_SHED
GCU: READY2LOADB
6  PDCU A: BC1_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: SG_OC
GCU: SPARE
PDCU A: EXT_PWR_ON  ON* / OFF*  ON* / OFF*
PDCU B: GEN1_OC
GCU: SG_RDY2LD
8  PDCU A: APUC1_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: GALLEY_OFF
GCU: FAN_OFF
9  PDCU A: STARTMODE_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: BC1_B_ST
GCU: GLC_AUX
10  PDCU A: GLC4_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: GEN2_OC
GOU: GCS_ON
Initial Issue  : Aug 13/09  80232190-24-01
Revision Date : Aug 13/09
©: Goodrich Power Systems - 2009 All rights reserved.  Page 7 of 9

### Page 10 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232190-24-01
Circuit No.  Function  RED LED  GREEN LED
11  PDCU B: GPC2_B_ST  ON* / OFF*  ON* / OFF*
12  PDCU B: BTC2_B_ST  ON* / OFF*  ON* / OFF*
13  PDCU A: SPARE_OGO  ON* / OFF*  ON* / OFF*
PDCU B: GEN3_OC
14  PDCU A: BTC2_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: ISOL_TIED
15  PDCU A: WOW_A_L  ON* / OFF*  ON* / OFF*
PDCU B: APUC1_B_ST
16  PDCU A: WOW_A_R  ON* / OFF*  ON* / OFF*
PDCU B: BTC3_B_ST
17  PDCU A: STBY_PUMP_ON  ON* / OFF*  ON" / OFF*
PDCU B: WOW_B_L
18  PDCU A: BTC3_A  _ST  ON* / OFF*  ON* / OFF*
PDCU B: CABIN_OFF
19  PDCU A: HSCB_SBEP_ON  ON* / OFF*  ON* / OFF*
PDCU B: GLC2_B_ST
20  PDCU A: GPC1_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: BAT1_GP_OC_IN
21  PDCU B: SPARE_OG1  ON* / OFF*  ON* / OFF*
22  PDCU B: BC2_B_ST  ON* / OFF*  ON* / OFF*
23  PDCU B: SPARE_CONT_CTL  ON* / OFF*  ON* / OFF*
24  PDCU B: GPC1_B_ST  ON* /OFF*  ON* /OFF*
25  PDCU B: STARTMODE_B_ST  ON* / OFF*  ON* / OFF*
26  PDCU B: GLC1_B_ST  ON* / OFF*  ON* / OFF*
27  PDCU B: B_GPU_WOW  ON* / OFF*  ON* / OFF*
28  PDCU B: GEN4_OC  ON* / OFF*  ON* / OFF*
29  PDCU B: EMERG_ISOL_B_ST  ON* / OFF*  ON* / OFF*
30  PDCU B: WOW_B_R  ON* / OFF*  ON* / OFF*
35  PDCU B: RAT_WOW  ON* / OFF*  ON* / OFF*
36  PDCU A: BATT_HEATER  ON* / OFF*  ON* / OFF*
37  GCU: STARTMODE  ON* / OFF*  ON* / OFF*
38  GCU: GENOFF  ON* / OFF*  ON* / OFF*
Initial Issue  : Aug 13/09  80232190-24-01
Revision Date: Aug 13/09
©: Goodrich Power Systems - 2009 All rights reserved  Page 8 of 9

### Page 11 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232190-24-01
Circuit No.  Function  RED LED  GREEN LED
39  PDCU B: BAT1_GP_OC_OUT  ON* / OFF*  ON* / OFF*
GCU: GENOC
Initial Issue  : Aug 13/09  80232190-24-01
Revision Date : Aug 13/09
©: Goodrich Power Systems - 2009 All rights reserved.  Page 9 of 9

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.