# Goodrich Service Bulletin 80232191-24-01

Copy: No revision named ("U.S. DOT/FAA - Service Bulletin (Goodrich - B PT.)"), 11 pages: PDF https://openairdocs.org/files/sha256/4d/ff/4dff3e790a4b46ff136b33e4e8a498c2c8bffe2c42bb8560673d595e65829ad0; text https://openairdocs.org/service-documents/goodrich/sb-80232191-24-01/file/4dff3e790a4b.md. Rights: © Goodrich. Filed by the FAA in regulations.gov docket FAA-2012-0265; AD 2012-12-18 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Goodrich](https://openairdocs.org/service-documents/goodrich.md)
- Type: Service bulletin (Service Bulletin)
- Number: 80232191-24-01
- Page: https://openairdocs.org/service-documents/goodrich/sb-80232191-24-01

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2012-12-18](https://openairdocs.org/ad/2012-12-18.md), effective Jul 30, 2012: No revision named

Also cited in [1 proposed AD](https://openairdocs.org/service-documents/goodrich/sb-80232191-24-01/proposed.md).

## Text (11 pages)

Rights: © Goodrich. Filed by the FAA in regulations.gov docket FAA-2012-0265; AD 2012-12-18 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. This text is OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232191-24-01
Goodrich Power Systems
Westfield Road
Pitstone LU7 9GT England
0044 1296 663000
SERVICE BULLETIN
STANDARD
ELECTRICAL POWER - PDCU B PT. NO. 80232191 AND 80231925/S3 INSPECTION/
CHECK OF THE TRANSIENT SUPPRESSION DIODES INSTALLED
INITIAL ISSUE
OF
SERVICE BULLETIN
80232191-24-01
AIRCRAFT APPLICABILITY DASSAULT FALCON 7X
1. Instructions
A. The Service Bulletin was written under EASA Approval No. UK.145.00858.
B. The technical content of this document is approved under the authority of DOA No. EASA.21J.051.
Copyright in this Service Bulletin and associated documents and drawings belongs to Goodrich Power Systems and all rights are reserved
No reproduction of all or part of this Service Bulletin shall be made without the prior written consent of Goodrich Power Systems.
This document contains information that may be confidential and its disclosure to others requires the written consent of Goodrich Power
Systems.

### Page 2 (OCR)

GooDRIcH
SERVICE BULLETIN
Number 80232191-24-01
INTENTIONALLY BLANK

### Page 3 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232191-24-01
1.  Planning Information
A. Effectivity
(1) This Service Bulletin (SB) applies to the Goodrich Corporation PDCU B Cards Pt. No. 80232191
and 80231925/S3 installed in the Left and Right Primary Power Distribution Box (PPDB), installed
on the Falcon 7X aircraft.
B. Concurrent Requirements
(1) None.
C. Reason
(1) Dassault Aviation has performed an analysis of aircraft-level effects associated with degradation of
33 Volt Transient Voltage Suppression (TVS) Diode in the Primary Distribution Control Unit (PDCU)
and Generator Control Unit (GU) printed circuit board assemblies.
D. Description
(1) The TVS Diodes have been categorised based on the severity of the effect. This SB gives the
procedures necessary to identify the degradation of "Priority 1 and 2" TVS Diodes.
E. Compliance recommendation
(1) At the next removal of a PDCUB card.
F. Approval
(1) The technical content of this document is approved under the authority of DOA No. EASA.21J.051.
G. Manpower
(1) 0.25 Man hours
H. Weight and Balance
(1) None.
Electrical Load Data
(1) None.
J. Software Accomplishment Summary
(1) Not applicable
K. References
(1) This SB was written using Goodrich Engineering Report PG0900400ED and rework drg 80232215
as source data.
Other Publications Affected
Goodrich ACMM for the PDCU-B CARD ASSEMBLY Part No. 80232190, ATA No. 24-61-09
will be revised to include the data contained in this SB.
Goodrich CMM for the Left PPDB, Part No. SW02101, ATA No. 24-61-01 will be revised to
reference the data contained in this SB
Goodrich CMM for the Right PPDB, Part No. SW02201, ATA No. 24-61-02 will be revised to
reference the data contained in this SB
M. Interchangeability or Intermixability of Parts
(1) Not applicable
Initial Issue  : Aug 13/09  80232191-24-01
Revision Date : Aug 13/09
Page 1 of 9
Goodrich Power Systems - 2009 All rights reserved.

### Page 4 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232191-24-01
2.  Material Information
A.  Material - Price and Availability
(1) Not Applicable.
B. Industry Support Program
(1) Not Applicable.
C. Material Necessary for each Component/Engine
(1) Not Applicable.
D. Spare Parts Availability
(1) Not Applicable.
E. Re-identified Parts
(1) None.
Tooling - Price and Availability
(1) The tools given below are necessary for this SB and are to be procured from the sources given.
Prices and lead times for Goodrich tools are available on request.
Qty  Part Number  Source  Keyword
1  Commercially Available  ESD Surface mat and
wrist band
TE2-0658  Goodrich Power  Falcon multi-channel
Systems  transorb tester (33V)
1  Commercially Available  Power supply 48V D.C.
2  Locally Made  Ground lead with 4mm
plug terminations
2  Commercially Available  Crocodile clip
3.  Accomplishment Instructions
A.  General
CAUTION: THE SPB CONTAINS ITEMS THAT ARE ELECTROSTATIC-DISCHARGE SENSITIVE
(ESDS), OBEY APPROVED INDUSTRY PRECAUTIONS WHEN YOU TOUCH, REMOVE
OR INSTALL PARTS. DAMAGE CAN OCCUR FROM ELECTROSTATIC DISCHARGE.
NOTE: This SB is intended for use on a PDCU B that is removed from the PPDB and off the aircraft.
(1) Place the PDCUB card on the ESD mat.
(2) Connect a ground lead to the ground socket of the test-set and a suitable earth point.
(3)  Connect the DC plug from the Power Supply Unit (PSU) to the 48 volts socket on the side of the
test-set.
(4)  Connect mains lead from the PSU to an applicable a.c. outlet and apply mains power.
Initial Issue  : Aug 13/09  80232191-24-01
Revision Date : Aug 13/09
Goodrich Power Systems - 2009 All rights reserved.  Page 2 of g

### Page 5 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232191-24-01
(5) Push the "TEST" button on the test-set, make sure the 40 RED LEDs illuminate.
NOTE: If, the RED LEDs do not illuminate the test set is damaged.
B.  Procedure
(1) Plug the board into the PDCUB connector on the test-set (Ref. Fig. 1).
NOTE: The top side of the board (the side with the main connector) must face you.
(2)  Connect a ground lead to the socket "GROUND" on the test-set. Use a crocodile clip and connect
the ground lead to the thermal plane of the PDCUB card (Ref. Fig. 2).
(3) Record serial number of the PDCUB card and the test-set on the Results sheet.
(4) Push the "TEST" button on the test-set, record the status of all the LEDs on the Result Sheet
Appendix 1.
NOTE: This is to collect data for possible future enhancements.
(5) Release the test button.
(6) Push the "TEST" button on the test-set, and make sure the circuit LEDs listed (Ref. Table 1) are all
GREEN.
Table 1 LED Pass PDCU B
Circuit No.  Function  RED LED  GREEN LED  Result
2  GLC3 B ST  OFF  ON  PASS
4  BTC1 B ST  OFF  ON  PASS
7  GEN1 OC  OFF  ON  PASS
10  GEN2 OC  OFF  ON  PASS
12  BTC2 B ST  OFF  ON  PASS
13  GEN3 OC  OFF  ON  PASS
14  ISOL TIED  OFF  ON  PASS
16  ВTC3 B ST  OFF  ON  PASS
19  GLC1 B ST  OFF  ON  PASS
20  BAT1 GP OC IN  OFF  ON  PASS
26  GLC1 B ST  OFF  ON  PASS
29  EMERG ISOL B  OFF  ON  PASS
STATUS
35  RAT WOW  OFF  ON  PASS
39  BAT1 GP OC OUT  OFF  ON  PASS
(7) Release the test button.
Initial Issue  : Aug 13/09  80232191-24-01
Revision Date: Aug 13/09
©: Goodrich Power Systems - 2009 All rights reserved.  Page 3 of 9

### Page 6 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232191-24-01
(8)  If, a RED LED is ON or a GREEN LED is OFF (Ref. Table 1), the PDCUB card must be returned to
Goodrich Power systems.
C. Completion
(1) Disconnect and remove the ground lead and crocodile clip from the thermal plane of the PDCU B
card.
(2) Remove the PDCUB card from the test-set.
(3) Remove a.c. mains power and disconnect the PSU from the a.c. outlet..
(4) Disconnect the PSU from the 48 volts socket on the side of the test-set.
(5) Remove the ground lead from the ground socket of the test-set and the earth point.
Initial Issue  : Aug 13/09  80232191-24-01
Revision Date : Aug 13/09
©: Goodrich Power Systems - 2009 All rights reserved.  Page 4 of 9

### Page 7 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232191-24-01
GCU
GROUND  PDCU B
PDCU A
TEST
01  02  03  04  05  07  _08  10
POCU A  E2-02_ON  ARUCIL AUST  STARTM ICE ALST  BUSALAST
0pTL0  TALLET OFF  ROUBLET  JENA
OcU  PARTMODE ALET  THE  PARLOFF  HER ON
•0  00  00  •0  •0  •0  •0
•0  •0  •0  •0  •0  •0  00  •0
•0  00  •0  •0  •0  •0  •0
00  •0  •0  •0  00  00  •0
D7X_SB_2401_0002_01_0
Test set TE2-0658
Figure 1
Initial Issue  : Aug 13/09  80232191-24-01
Revision Date : Aug 13/09
©: Goodrich Power Systems - 2009 All rights reserved.  Page 5 of 9

### Page 8 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232191-24-01
ESD plane
000000  o 80
000
00
00000
00 %
D7X_SB_2401_0001_01
PDCU B
Figure 2
INTENTIONALLY BLANK
Initial Issue  : Aug 13/09  80232191-24-01
Revision Date : Aug 13/09
Goodrich Power Systems - 2009 All rights reserved.  Page 6 of 9

### Page 9 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232191-24-01
Appendix 1
A.  Complete the Results Table.
NOTE: * Delete as necessary.
Table 2 Results Table
Board type  Serial No.  TE2-0658, Serial No.
Circuit No.  Function  RED LED  GREEN LED
PDCU A: BUS_TIE_MAN  ON* / OFF*  ON* / OFF*
PDCU B: GLC4_B_ST
2  PDCU A: BTC1_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: GLC3_B_ST
GCU: STAR
PDCU A: GLC3_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: GALLEY_NOT_SHED
GCU: TRIP
4  PDCU A: GLC2_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: BTC1_B_ST
GCU: READY2LOADA
PDCU A: GLC1_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: CABIN_NOT_SHED
GCU: READY2LOADB
6  PDCU A: BC1_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: SG_OC
GCU: SPARE
7  PDCU A: EXT_PWR_ON  ON* / OFF*  ON* / OFF*
PDCU B: GEN1_OC
GCU: SG_RDY2LD
PDCU A: APUC1_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: GALLEY_OFF
GCU: FAN_OFF
9  PDCU A: STARTMODE_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: BC1_B_ST
GCU: GLC_AUX
10  PDCU A: GLC4_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: GEN2_OC
GCU: GCS_ON
Initial Issue  : Aug 13/09  80232191-24-01
Revision Date : Aug 13/09
Goodrich Power Systems - 2009 All rights reserved.  Page 7 of 9

### Page 10 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232191-24-01
Circuit No.  Function  RED LED  GREEN LED
11  PDCU B: GPC2_B_ST  ON* / OFF*  ON* / OFF*
12  PDCU B: BTC2_B_ST  ON* / OFF*  ON* / OFF*
13  PDCU A: SPARE_OGO  ON* / OFF*  ON* / OFF*
PDCU B: GEN3_OC
14  PDCU A: BTC2_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: ISOL_TIED
15  PDCU A: WOW_A_L  ON* / OFF*  ON* / OFF*
PDCU B: APUC1_B_ST
16  PDCU A: WOW_A_R  ON* / OFF*  ON* / OFF*
PDCU B: BTC3_B_ST
17  PDCU A: STBY_PUMP_ON  ON* / OFF*  ON* / OFF*
PDCU B: WOW_B_L
18  PDCU A: BTC3_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: CABIN_OFF
19  PDCU A: HSCB_SBEP_ON  ON* / OFF*  ON* / OFF*
PDCU B: GLC2_B_ST
20  PDCU A: GPC1_A_ST  ON* / OFF*  ON* / OFF*
PDCU B: BAT1_GP_OC_IN
21  PDCU B: SPARE_OG1  ON* / OFF*  ON* / OFF*
22  PDCU B: BC2_B_ST  ON* / OFF*  ON* / OFF*
23  PDCU B: SPARE_CONT_CTL  ON* / OFF*  ON* / OFF*
24  PDCU B: GPC1_B_ST  ON* /OFF*  ON* /OFF*
25  PDCU B: STARTMODE_B_ST  ON* / OFF*  ON* / OFF*
26  PDCU B: GLC1_B_ST  ON* / OFF*  ON* / OFF*
27  PDCU B: B_GPU_WOW  ON* / OFF*  ON* / OFF*
28  PDCU B: GEN4_OC  ON* / OFF*  ON* / OFF*
29  PDCU B: EMERG_ISOL_B_ST  ON* / OFF*  ON* / OFF*
30  PDCU B: WOW_B_R  ON* / OFF*  ON* / OFF*
35  PDCU B: RAT_WOW  ON* / OFF*  ON* / OFF*
36  PDCU A: BATT_HEATER  ON* / OFF*  ON* / OFF*
37  GCU: STARTMODE  ON* / OFF*  ON* / OFF*
38  GCU: GENOFF  ON* / OFF*  ON* / OFF*
Initial Issue  : Aug 13/09  80232191-24-01
Revision Date : Aug 13/09
Goodrich Power Systems - 2009 All rights reserved.  Page 8 of 9

### Page 11 (OCR)

GOODRICH
SERVICE BULLETIN
Number 80232191-24-01
Circuit No.  Function  RED LED  GREEN LED
39  PDCU B: BAT1_GP_OC_OUT  ON* / OFF*  ON* / OFF*
GCU: GENOC
Initial Issue  : Aug 13/09  80232191-24-01
Revision Date : Aug 13/09
©: Goodrich Power Systems - 2009 All rights reserved.  Page 9 of 9

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.