### Page 1

Service Bulletin 
SB059 B QS-FO 89B 
 
Nr. Ausgabe/ no. edition Referenziert in/ referenced in Seite / Page 
QS-FO 89B BH Part 3 (DOH) 1 of 6 
 
Ensuring correct torque tightening 
2 General 
Effectivity: All Hoffman HO-V72 propellers that have not been serviced directly by Hoffman propellers (see 5.1) 
Reason: Several propellers were found with improperly tightened blade retention nuts 
Description: 
This service document supersedes the ASB001 B.                                     
This service bulletin describes required instructions and the proper 
procedure for tightening the blade retention nut with the correct torque.  
 
3 Revision History 
Revision Description/Reason for Revision Date 
A Initial Issue 2022-02-11 
B Effectivity limited to HO-V72 propeller type, inclusion and summary of the alert service bulletin 001, ref SB058 added, ref CMM deleted 2022-02-23 
 
4 Description 
Manpower: 2 – 6 hours (depending on number of blades) 
Material – Cost and Availability: 
On request (approx. 50€/per blade) 
VP-parts available at Hoffmann Propeller / Silicon etc. 
available at Hoffmann Propeller or at public stores. 
Tooling: As described in 5.3. 
Weight and Balance: N/A 
Electrical Load Data: N/A 
Software Accomplishment Summary: N/A 
References: 
Operation and Maintenance Manuals (E243 & 2505.73) as 
applicable, SB057, SB053, SB058 
 
Other Publications: None 
Family Tree Chart of Modification Relationship: N/A 
Interchangeability or Intermixability of Parts: N/A

### Page 2

Service Bulletin 
SB059 B QS-FO 89B 
 
Nr. Ausgabe/ no. edition Referenziert in/ referenced in Seite / Page 
QS-FO 89B BH Part 3 (DOH) 2 of 6 
 
5 Accomplishment Instructions 
 
5.1 Effectivity evaluation and required steps 
 
 
 
 
If the propeller is not affected, no further steps are required.  
 
If the propeller is affected the following instructions are required: 
- Before each flight check blades for shake.  If blade shake is found the propeller is not considered 
serviceable and the aircraft should not be flown. 
- If vibrations occur during flight, reduce the power, and land as soon as possible, the propeller may 
not be serviceable, the cause of the vibration should be investigated and if propeller suspected it 
should be considered unserviceable and aircraft should not be flown. 
- Within next 90 flight hours the procedure according to the following chapter 6 in this service bulletin 
and the final check according to the following chapter 7 in this service bulletin must be carried out. 
 
After the steps described in the following chapters 6 & 7 of this service bulletin has been carried out the 
propeller can be operated normally. 
  
Is the propeller affected ?
Propeller last service was at 
Hoffmann Propeller
Propeller is
not affected
Propeller last service was not at 
Hoffmann Propeller
Request the service station whether the blade retention nuts were tightened at 
the last service according to the current service documents.   
The service station must check whether the tightening procedure used for the 
blade retention nuts corresponds similarly to the procedure in SB0057. If the 
service station needs assistance with the assessment, it must contact Hoffmann 
Propeller.
The blade retention nuts were not tightened according to the current service 
documents during the last service. or it cannot be ensured. 
Propeller is
affected
The blade retention nuts were tightened during the last 
service according to the current service documents.
Propeller is
not affected

### Page 3

Service Bulletin 
SB059 B QS-FO 89B 
 
Nr. Ausgabe/ no. edition Referenziert in/ referenced in Seite / Page 
QS-FO 89B BH Part 3 (DOH) 3 of 6 
 
5.2 Needed parts and consumable materials 
- One locking plate each blade. For the correct part number see Table 1. (Available by 
Hoffmann Propeller) 
- Stainless steel locking wire 0.8 mm (0.03 inch) 
- Silicone according Table 1 (Available by Hoffmann Propeller) 
- Masking tape 
- Cleaning agent 
 
Propeller type Part-No. Locking plate Silicone 
symmetric asymmetric 
HO-V72 VP20-572  RTV 109 (silver) 
Table 1: Part numbers of locking plates and silicone type. 
 
 
5.3 Tools required 
- Blade nut spanner and adapter according SB057 (Available by Hoffmann Propeller) 
- Calibrated torque wrench with adaptor according SB057 (Available by Hoffmann Propeller) 
- Wire Lock plier 
 
 
 
Figure 1 Tool designations

### Page 4

Service Bulletin 
SB059 B QS-FO 89B 
 
Nr. Ausgabe/ no. edition Referenziert in/ referenced in Seite / Page 
QS-FO 89B BH Part 3 (DOH) 4 of 6 
 
6 Procedure 
6.1 General Preparation 
- Mark the position of the spinner to ensure it can be reattached 
- Remove the spinner by loosening the Philips screws 
- Mark the position of the counterweight to ensure it can be reattached 
 
 
- Remove the counterweight by loosening the stop nuts. 
 
6.2 Blade preparation and installation 
 
- Remove the lock plate 
 
 
- If balance weights are installed on the blade retention nut mark the position and remove 
them also.

### Page 5

Service Bulletin 
SB059 B QS-FO 89B 
 
Nr. Ausgabe/ no. edition Referenziert in/ referenced in Seite / Page 
QS-FO 89B BH Part 3 (DOH) 5 of 6 
 
- Cut the silicone joint, take care not to damage the propeller hub or blade retention nut 
 
 
- Remove the silicone with a brass or plastic spatula 
 
 
- Clean the surface with cleaning agent 
Caution do not use acceton / MEK (Methyl Mthyl Ketone) 
- Break off the rest of the silicone by opening the blade retention nut half a turn, using the 
blade nut spanner 
- Remove the residual silicone as before 
- Retorque according to SB057 “procedure of tightening blade nuts” 
- If needed drill a new lock plate 
- Prepare area for silicone application (cleaning etc.) 
- Use sealing compound RTV 109 and fill the gap (joint) between hub socket (It is 
recommended to mask the blade retention nut with insulating tape or similar to obtain a 
clean seal). 
- Attach lock plate and tighten it with slotted screws (3Nm). 
- Attach balance weight in wet silicone if any were installed before. Use position as marked 
before removal and tighten it with slotted screws (3Nm). 
- Wire lock the slotted screws 
- Install counterweights, if applicable, as marked before, showing in the correct direction. 
Torque stop nuts M8 with 10 - 12 Nm. (To see the standard position of the counterweights 
refer to SB058) 
- Attach spinner to the marked position as described in the applicable OMM

### Page 6

Service Bulletin 
SB059 B QS-FO 89B 
 
Nr. Ausgabe/ no. edition Referenziert in/ referenced in Seite / Page 
QS-FO 89B BH Part 3 (DOH) 6 of 6 
 
7 Final checks 
- Before first use, check that the silicone seal between the blade nut and the hub is fully 
sealed and that the silicone has completely cured. 
- Check if all screws are wire locked. 
- Check if all lock plates and balance weights are at the right position. 
- Check the blades for blade play. 
Only blade angle play up to 0.5° is allowed. 
Axial play is not allowed. 
It is recommended to mark all screws and bolts with locking varnish. 
8 Approval Statement 
The technical content of this document is approved under the authority of the DOA ref. EASA. 21J.083.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.