# International Aero Engines Non-Modification Service Bulletin V2500-ENG-72-0615: U.S. DOT/FAA - Service information - 1

- Rights: © IAE International Aero Engines AG. Filed by the FAA in regulations.gov docket FAA-2009-1100; AD 2012-09-09 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [International Aero Engines Non-Modification Service Bulletin V2500-ENG-72-0615](https://openairdocs.org/service-documents/iae/v2500-eng-72-0615.md)
- Title as filed: U.S. DOT/FAA - Service information - 1
- Pages: 117
- PDF: https://openairdocs.org/files/sha256/0a/54/0a5400a2036b20e56c0d61649f2a6bf8664cd66c8066791a3d8c08afeacc5361
- Page: https://openairdocs.org/service-documents/iae/v2500-eng-72-0615/file/0a5400a2036b

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

This document transmits the Revision 3 of Non-Modification Service Bulletin
V2500-ENG-72-0615.
Document History
Non-Modification Service Bulletin Revision Status
Initial Issue. Jul.19/10.
Revision 1. Aug. 2/10.
Revision 2. Nov.24/10.
Non-Modification Service Bulletin Revision 3
Remove Incorporate Reason for change
Sep.20/11
V2500-A1/A5 SERIES PROPULSION SYSTEM NON-MODIFICATION SERVICE BULLETIN
V2500−ENG−72−0615
Transmittal - Page 1 of 2
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG (date as above). All rights reserved.
CHECK THAT ALL PREVIOUS TRANSMITTALS HAVE BEEN INCORPORATED
If any have not been received please advise IAE International Aero Engines AG

### Page 2

All pages of the
Non-Modification
Service Bulletin.
Pages 1 to 114 of
the Non-Modification
Service Bulletin.
To revise the
effectivity.
To revise the
compliance.
To delete Part 2 and
3.
To introduce a blend
procedure for the A5
variant.
Editorial changes.
To update the
illustrations.
V2500−ENG−72−0615
Transmittal - Page 2
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 3

1. Planning Information
A. Effectivity Data
(1) Airbus A319
(a) V2500-A5 Engines specified below:R
(i) Group A Engines:R
V10001, V10096, V10102, V10103, V10195, V10341, V10474, V10475,
V10478, V10481, V10490, V10503, V10518, V10519, V10937, V11482,
V11516, V11521, V11788, V11848, V11849, V11899, V11904, V11917,
V11937, V11939, V11982, V11980, V11978, V12000, V12002, V12037,
V12038, V12041, V12120, V12122, V12129, V12131, V12142, V12148,
V12150, V12166, V12168, V12174, V12178, V12227, V12242, V12252,
V12263, V12270, V12289, V12294, V12327, V12333, V12345, V12346,
V12347, V12352, V12354, V12389, V12391, V12400, V12404, V12406,
V12408, V12414, V12416, V12420, V12425, V12427, V12445, V12451,
V12477, V12480, V12489, V12541, V12543, V12567, V12569, V12573,
V12575, V12576, V12586, V12601, V12603, V12620, V12623, V12646,
V12668, V12705, V12721, V12723, V12725, V12751, V12753, V12754,
V12756, V12758, V12765, V12768, V12772, V12774, V12881, V12888,
V12921, V12930, V12968, V13071, V13124, V13137, V13170, V13187,
V15001, V15003, V15004, V15006, V15007, V15009, V15033, V15050,
V15104, V15111, V15161, V15162, V15168, V15191, V15205, V15216.
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
NOTE: Group A engines are those which are currently or were
formerly stationed and operated in India.
R
R
(ii) Group B Engines:R
V2522-A5, V2524-A5, V2527M-A5 Engines prior to Serial No.
V13181 (A5 Standard and A5 SelectOne™
R
R Retrofit Standard).
V2522-A5, V2524-A5, V2527M-A5 Engines prior to Serial No.
V15204 and Engines with Serial No. V15205 to V15245 (A5
SelectOne™
R
R
R Production Standard).
NON-MODIFICATION SERVICE BULLETIN - ENGINE - HIGH PRESSURE (HP) COMPRESSOR - STAGE 3
TO 8 COMPRESSOR DRUM - ULTRASONIC INSPECTION PROCEDURE
V2500−ENG−72−0615
Page 1 of 114
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 4

(2) Airbus A320
(a)R V2500-A1 Engines specified below:
(i) Group A Engines:R
V0008, V0013, V0023, V0024, V0026, V0027, V0028, V0030, V0036,
V0038, V0043, V0044, V0045, V0050, V0052, V0056, V0057, V0059,
V0062, V0063, V0064, V0068, V0070, V0071, V0072, V0073, V0074,
V0077, V0079, V0080, V0082, V0087, V0092, V0094, V0095, V0097,
V0098, V0100, V0102, V0105, V0107, V0108, V0109, V0114, V0116,
V0117, V0118, V0125, V0133, V0134, V0140, V0145, V0149, V0150,
V0151, V0158, V0160, V0180, V0197, V0198, V0200, V0220, V0221,
V0222, V0224, V0228, V0233, V0234, V0236, V0238, V0243, V0244,
V0252, V0257, V0270, V0271, V0272, V0273, V0278, V0279, V0280,
V0281, V0282, V0290, V0296, V0297, V0298, V0299, V0303, V0304,
V0306, V0307, V0308, V0309, V0312, V0329, V0330, V0338, V0341,
V0342, V0345, V0346, V0350, V0352, V0353, V0354, V0355, V0356,
V0357, V0358, V0359 and V0360.
R
R
R
R
R
R
R
R
R
R
R
R
R
NOTE: Group A engines are those which are currently or were
formerly stationed and operated in India.
R
R
(ii) Group B Engines:R
All other Engine Serial numbers.R
(b) V2500-A5 Engines specified below:R
(i) Group A Engines:R
V10001, V10096, V10102, V10103, V10195, V10341, V10474, V10475,
V10478, V10481, V10490, V10503, V10518, V10519, V10937, V11482,
V11516, V11521, V11788, V11848, V11849, V11899, V11904, V11917,
V11937, V11939, V11982, V11980, V11978, V12000, V12002, V12037,
V12038, V12041, V12120, V12122, V12129, V12131, V12142, V12148,
V12150, V12166, V12168, V12174, V12178, V12227, V12242, V12252,
V12263, V12270, V12289, V12294, V12327, V12333, V12345, V12346,
V12347, V12352, V12354, V12389, V12391, V12400, V12404, V12406,
V12408, V12414, V12416, V12420, V12425, V12427, V12445, V12451,
V12477, V12480, V12489, V12541, V12543, V12567, V12569, V12573,
V12575, V12576, V12586, V12601, V12603, V12620, V12623, V12646,
V12668, V12705, V12721, V12723, V12725, V12751, V12753, V12754,
V12756, V12758, V12765, V12768, V12772, V12774, V12881, V12888,
V12921, V12930, V12968, V13071, V13124, V13137, V13170, V13187,
V15001, V15003, V15004, V15006, V15007, V15009, V15033, V15050,
V15104, V15111, V15161, V15162, V15168, V15191, V15205, V15216.
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
NOTE: Group A engines are those which are currently or were
formerly stationed and operated in India.
R
R
V2500−ENG−72−0615
Page 2
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 5

(ii) Group B Engines:R
V2527-A5, V2527E-A5 Engines prior to Serial No. V13181 (A5
Standard and A5 SelectOne™
R
R Retrofit Standard).
V2527-A5, V2527E-A5 Engines prior to Serial No. V15204 and
Engines with Serial No. V15205 to V15245 (A5 SelectOne™
R
R
Production Standard).
R
R
(3) Airbus A321
(a) V2500-A5 Engines specified below:R
(i) Group A Engines:R
V10001, V10096, V10102, V10103, V10195, V10341, V10474, V10475,
V10478, V10481, V10490, V10503, V10518, V10519, V10937, V11482,
V11516, V11521, V11788, V11848, V11849, V11899, V11904, V11917,
V11937, V11939, V11982, V11980, V11978, V12000, V12002, V12037,
V12038, V12041, V12120, V12122, V12129, V12131, V12142, V12148,
V12150, V12166, V12168, V12174, V12178, V12227, V12242, V12252,
V12263, V12270, V12289, V12294, V12327, V12333, V12345, V12346,
V12347, V12352, V12354, V12389, V12391, V12400, V12404, V12406,
V12408, V12414, V12416, V12420, V12425, V12427, V12445, V12451,
V12477, V12480, V12489, V12541, V12543, V12567, V12569, V12573,
V12575, V12576, V12586, V12601, V12603, V12620, V12623, V12646,
V12668, V12705, V12721, V12723, V12725, V12751, V12753, V12754,
V12756, V12758, V12765, V12768, V12772, V12774, V12881, V12888,
V12921, V12930, V12968, V13071, V13124, V13137, V13170, V13187,
V15001, V15003, V15004, V15006, V15007, V15009, V15033, V15050,
V15104, V15111, V15161, V15162, V15168, V15191, V15205, V15216.
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
NOTE: Group A engines are those which are currently or were
formerly stationed and operated in India.
R
R
(ii) Group B Engines:R
V2530-A5, V2533-A5 Engines prior to Serial No. V13181 (A5
Standard and A5 SelectOne™
R
R Retrofit Standard).
V2530-A5, V2533-A5 Engines prior to Serial No. V15204 and
Engines with Serial No. V15205 to V15245 (A5 SelectOne™
R
R
Production Standard).
R
R
NOTE: For an engine not to require an ultrasonic inspection in accordance with
this Non-Modification Service Bulletin, the condition that follows must
be achieved:
R
R
R
V2500−ENG−72−0615
Page 3
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 6

The engine must have a new HP compressor stage 3-8 drum of Service
Bulletin V2500-ENG-72-0470 or Service Bulletin V2500-ENG-72-0606 and new
nuts of Service Bulletin V2500-ENG-72-0596 installed together at the
same time.
R
R
R
R
B. Concurrent Requirements
None.
C. Reason
(1) Condition:
Crack indications have been found on the High Pressure (HP) compressor
stage 3-8 drum assemblyR during overhaul.
(2) Background:
Crack indications were highlighted during an Engine Manual crack
inspection of the stage 7-8 disc internal cavity.
(3) Objective:
To do an ultrasonic inspection procedure of the HP compressor stage 8
disc.
(4) Substantiation:
Crack indications have been found on the HP compressor stage 3-8 drum
assembly during overhaul. An ultrasonic inspection was developed and has
shown the capability of detecting cracks in service.
(5) Effects of Bulletin on:
(a) Removal/Installation:
Not affected.
(b) Disassembly/Assembly:
Not affected.
(c) Cleaning:
Not affected.
(d) Inspection/Check:
Not affected.
V2500−ENG−72−0615
Page 4
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 7

(e) Repair:
Not affected.
(f) Testing:
Not affected.
(6) Supplemental Information
None.
D. Description
ThisR Non-Modification Service Bulletin instructs ultrasonic inspection
procedures of the HP compressor stage 8 disc that can be carried out "In
Service" or "At Overhaul/ Shop Visit".
(1) The procedures are to inspect the internal stage 8 disc for cracks, on the
outer diameter adjacent to the stage 7-8 EB weld land and on the inner
diameter at the inner radius position.
(2) A shear wave ultrasonic inspection probe is positioned on the ceramic
lining of the stage 7-8R stator, located on the outer diameter of the disc.
(3) Engines affected are listed in paragraph 1.A. Effectivity.
NOTE: The Accomplishment Instruction ofR this Service Bulletin is divided into
two INSTRUCTIONs as follows:
INSTRUCTION I - Applicable for engines "In Service".
INSTRUCTION I of this Service Bulletin is divided into two PARTs as
follows:
PART A - Applicable for V2500-A1 engines.
PART B - Applicable for V2500-A5 engines.
INSTRUCTION II - Applicable for engines "At Overhaul/Shop Visit".
INSTRUCTION II of this Service Bulletin is divided into two PARTs as
follows:
PART A - Applicable for V2500-A1 engines.
PART B - Applicable for V2500-A5 engines.
V2500−ENG−72−0615
Page 5
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 8

E. Compliance
Category 3
Compliance times for Group A Engines:R
Inspection
location
R
R
HP
compressor
3-8 Drum
cycles since
new
R
R
R
R
R
ThresholdR FromR Regular Repeat
Inspection
Interval
R
R
R
Outer and
Inner
Diameters
R
R
R
>5000R Accomplish within 200
cycles.
R
R
Date of
Revision 3 of
NMSB
V2500-ENG-
R
R
R
R
72-0615.R
Not more than
750 cycles.
R
R
<5000R Accomplish within 200
cycles of the drum
reaching 5000 cycles.
R
R
R
NOTE: The threshold of 200 cycles within this compliance table applies to
engines which are not inspected yet.
R
R
An engine which is already inspected remains in a repeat inspection
interval of 750 cycles.
R
R
NOTE: To comply with the IAE design policy, IAE recommends to install a new HP
compressor stage 3 to 8 drum together with partially silver plated nuts
of Service Bulletin V2500-ENG-72-0596 standard by the 31st of December
2019.
R
R
R
R
Compliance times for Group B Engines:R
Inspection
location
R
R
HP
compressor
3-8 Drum
cycles since
new
R
R
R
R
R
ThresholdR FromR Regular Repeat
Inspection
Interval
R
R
R
Outer and
Inner
Diameters
R
R
R
Refer to the
USI drawdown
plan.
R
R
R
Refer to the USI drawdown
plan.
R
R
Date of
Revision 3 of
NMSB
V2500-ENG-
R
R
R
R
72-0615.R
Not more than
750 cycles.
R
R
NOTE: An engine which is already inspected remains in a repeat inspection
interval of 750 cycles.
R
R
NOTE: To comply with the IAE design policy, IAE recommends to install a new HP
compressor stage 3 to 8 drum together with partially silver plated nuts
of Service Bulletin V2500-ENG-72-0596 standard by the 31st of December
2019.
R
R
R
R
V2500−ENG−72−0615
Page 6
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 9 (OCR)

LAE  International
Aero Engines.  SERVICE BULLETIN
USI Drawdown Plan
1500
Cycles remaining until inspection required  1000
500
R
11000  11500  12000  12500  13000  13500  14000
Drum Cycles Since New on Effective Date of Revision 3
of this Non-Modification Service Bulletin
DRUMS WITH LESS THAN OR EQUAL 12000 CYCLES ON THE DAY OF ISSUE OF
REVISION 3 OF THIS NON-MODIFICATION SERVICE BULLETIN REQUIRE AN
INITIAL INSPECTION BEFORE THE DRUM REACHES 12500 CYCLES.
DRUMS BETWEEN 12001 CYCLES AND 13199 CYCLES ON THE DAY OF ISSUE OF
REVISION 3 OF THIS NON-MODIFICATION SERVICE BULLETIN REQUIRE AN
INITIAL INSPECTION WITHIN 500 CYCLES.
DRUMS BETWEEN 13200 CYCLES AND 13699 CYCLES ON THE DAY OF ISSUE OF
REVISION 3 OF THIS NON-MODIFICATION SERVICE BULLETIN REQUIRE AN
INITIAL INSPECTION BEFORE THE DRUM REACHES 13700 CYCLES.
DRUMS ABOVE 13700 CYCLES AND NOT ALREADY INSPECTED ON THE DAY OF
Готі0000375  ISSUE OF REVISION 3 OF THIS NON-MODIFICATION SERVICE BULLETIN
REQUIRE AN INSPECTION BEFORE THE NEXT FLIGHT.
R  Compliance times for Group B Engines
Jul. 19/10  V2500-ENG-72-0615
Sep. 20/11 Revision 3  Page 7
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 10

There are two conditions which can affect the Inspection start but not the
Inspection interval, refer to the tables below:
R
R
FPI Grace PeriodR
Permitted Grace PeriodR Required Engine ConditionR
(Shop Visit)R
2500 CyclesR Service Bulletin V2500-ENG-72-0596 incorporatedR
Cleaned in accordance with EM TASK
72-41-11-110-001
R
R
Inspected in accordance with EM TASK
72-41-11-200-001
R
R
NOTE: The FPI Grace Period interrupts/delays the ultrasonic inspection by 2500
cycles related to the achieved drum life.
R
R
Figure 28 provides a calculation example for Group A Engines.R
Figure 29 provides a calculation example for Group B Engines.R
ECI Grace PeriodR
Permitted Grace PeriodR Required Engine ConditionR
(Shop Visit)R
13000 CyclesR Inspected in accordance with Service Bulletin
V2500-ENG-72-0625
R
R
andR
Service Bulletin V2500-ENG-72-0596 incorporatedR
NOTE: The ECI Grace Period interrupts/delays the ultrasonic inspection by
13000 cycles related to the achieved drum life.
R
R
On completion of a successful ECI inspection and the 13000 cycles Grace
Period, the engine will return to the 750 cycles repeat inspection
interval.
R
R
R
F. Approval
The compliance statement and the procedures described in this Non-Modification
Service Bulletin have been shown to comply with the applicable Federal Aviation
Regulations and are FAA-APPROVEDR for the engine models listed.
G. Manpower
Estimated man-hours to carry out this Non-Modification Service Bulletin in
full:
V2500−ENG−72−0615
Page 8
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 11

(1) In Service
(a) Engines without heat shield retainers installed:
3 Hours
(b) Engines with heat shield retainers installed:
7 hours
(2) At Overhaul
(a) Engines without heat shield retainers installed:
3 Hours
(b) Engines with heat shield retainers installed:
6 hours
NOTE: The ultrasonic inspection defined in this NMSB must only be performed by
personnel qualified to ultrasonic inspection level 2 or higher in
accordance with EN4179 and/or NAS410 or alternative standards/
guidelines accepted by the applicable National Aviation Authority.
H. Weight and Balance
(1) Weight Change
None.
(2) Moment Arm
No effect.
(3) Datum
Engine Front Mount Centerline (Power Plant Station (PPS) 100).
I. Electrical Load Data
This Non-Modification Service Bulletin has no effect on the aircraft electrical
load.
J. Software Accomplishment Summary
Not Applicable.
K. References
For V2500-A1 Engines:
V2500−ENG−72−0615
Page 9
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 12

(1) Airbus A320 Aircraft Maintenance Manual (AMM) Chapters 70-30-00, 71-13-00,
72-00-00 and 75-32-52.
(2) IAE V2500 Engine Manual (E-V2500-1IA), Chapters 72-00-40 and 72-41-11.
(3) Overhaul Processes and Consumables Index.
(4) Internal Reference No. EC 10VR775C.R
For V2500-A5 Engines:
(1) Airbus A319, A320 and A321 Aircraft Maintenance Manual (AMM) Chapters
70-30-00, 71-13-00, 72-00-00 and 75-32-52.
(2) IAE V2500 Engine Manual (E-V2500-3IA), Chapters 72-00-40 and 72-41-11.
(3) Overhaul Processes and Consumables Index.
(4) SEN5088 Issue 1. "Significant shop findings on HPC 3-8 drum".
(5) SEN5088 Issue 2. "Significant shop findings on HPC 3-8 drum".
(6) SEN5088 Issue 3. "Significant shop findings on HPC 3-8 drum".
(7) Internal Reference No. EC 10VR775C.R
L. Other Publications Affected
None.
M. Interchangeability of Parts
Not applicable.
V2500−ENG−72−0615
Page 10
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 13

2. Material Information
A. Material - Price and Availability
None.
B. Industry Support Program
Not applicable.
C. The material data that follows is for each engine.
This Non-Modification Service Bulletin is for inspection only.
D. Instructions/Disposition Code Statements:
Parts Modification Conditions
Not applicable.
Spare Parts Availability
Not applicable.R
Cleaning, Inspection and Repair Information
Inspection procedure (Refer to paragraph 3. Accomplishment Instructions).
E. Tooling - Price and Availability
The tooling to comply with the inspections will be provided to operators on
free of charge (FOC) loan basis. To receive the FOC tooling, please follow the
ordering procedure outlined below:
(1) Submit a zero charge PO to IAE Spares (GPIAESPRTLG@IAEV2500.com)R with kit
tool number and, if applicable, drilling guide tool number to address
requested.
(2) Shipping and customs costs are the responsibility of the operator
Return of kits after use must use the following procedure:
(3) Submit an e-mail request to GPIAESPRTLG@IAEV2500.com.R Return details will
be provided by e-mail.
(4) Upon issuance of a MRA all return details of the kit will be provided.
Contact your CFD with any questions.
V2500−ENG−72−0615
Page 11
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 14

F. Re-identified Parts
Not Applicable.
G. Other Material Information Data
Not Applicable.
V2500−ENG−72−0615
Page 12
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 15

3. Accomplishment Instructions
INSTRUCTION I - APPLICABLE FOR ENGINES "IN SERVICE"
Part A - Applicable for V2500-A1 engines
A. General
Use the new inspection kit IAE2R19882 or the old inspection kit IAE2R19864 to
carry out an ultrasonic inspection on the outer diameter of the HP compressor
stage 8 disc adjacent to the stage 7-8 EB weld land.
NOTE: In order to reduce the potential for multiple-engine in-flight shutdown,
power loss, or other anomaly due to maintenance error, IAE recommends
that Operators avoid performing maintenance on multiple engines
installed on the same aircraft at the same time. If it is not possible
to avoid maintenance on more than one engine of an aircraft at the same
time, IAE recommends that additional controls are applied in order to
ensure that maintenance tasks have been completed as defined.
WARNING: YOU MUST BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE
ENGINE IS STOPPED. THE ENGINE PARTS CAN STAY HOT FOR ALMOST ONE HOUR.
WARNING: DO NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE
AN INJURY.R
(1) Obey all the WARNINGS and CAUTIONS in the procedures that are referred to.
(2) Consumable Materials
(a) Refer to the table that follows:
MATERIAL NO. DESIGNATION
V01-201R Distilled or De-ionised water
V10-058R Penetrating Oil
For the details of the consumable materials given in the table above,
refer to the Aircraft Maintenance Manual (AMM) TASK 70-30-00-918-010.
(3) Tools and Equipment
(a) Refer to the table that follows:
ITEM DESCRIPTION TOOL NUMBER
(a) Inspection kit contains the outer diameter
location inspection kit of item (b) in this
table and the inner diameter location
inspection kit of item (b) of the table in
section 3.K.(3)(a) of this Non-Modification
Service Bulletin.
OR
IAE2R19882
V2500−ENG−72−0615
Page 13
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 16

(b) Outer diameter location inspection kit
*(contains items (c) to (g)
IAE2R19864
(c) Ultrasonic probe manipulator assembly IAE2R19865
(d) Couplant feed manipulator IAE2R19867
(e) Couplant feed system IAE2R19807
(f) Working standard IAE2R19854
(g) MCX/BNC lead IAE2R19755
(h) Ultrasonic flaw detector, frequency
selectable in the 5.0 MHz range with
audible/visual electronic alarm gate
Not supplied
(i) 4 to 6 mm flexible borescope kit with image
capture capability
Not supplied
(j) Turning tool (if applicable) Not supplied
(k) Bolts (2 off) AS48516 or
4W0170
R
R
not supplied
(l) Washers to fit item (k) Not supplied
NOTE: 1. The lead for the ultrasonic probe is supplied with a BNC
connector installed. An adaptor may be required if
alternative equipment is used.
2. The compressor can be turned manually, but an electronic
turning tool is recommended to perform the inspection.
3. Care should be taken to keep the two working standards
IAE2R19854 and IAE2R19860 separate.
B. Get access to the HP compressor stage 7 bleed valve aperture that is installed
on the left side of the engine
(1) Deactivate the thrust reverser Hydraulic Control Unit (HCU) (Refer to the
Aircraft Maintenance Manual, Chapter 78-30-00).
(2) Open the applicable fan cowl doors (Refer to the Aircraft Maintenance
Manual, Chapter 71-13-00).
(3) Open the applicable half of the thrust reverser (Refer to the Aircraft
Maintenance Manual, Chapter 78-32-00).
C. Remove the HP stage 7 bleed valve air duct from the left side of the engineR
(1) Remove the HP stage 7 bleed valve air duct together with the HP compressor
stage 7 bleed valve
R
R (Refer to Figure 1)
(a) Allow the engine to cool for at least 2 hours with the cowl doors
open.
(b) Apply the approved penetrating oil CoMat 10-058 before the removal of
threaded parts. Let the parts soak at least 15 minutes.
V2500−ENG−72−0615
Page 14
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 17

(c) Seal all openings to prevent contamination from unwanted materials.
(d) Remove the coupling that attaches the IP bleed check valve to the HP7
bleed valve/cabin air duct (Refer to the Aircraft Maintenance Manual,R
TASK 36-11-41-00-010).
(e) Carefully overcome the initial torque of each bolt of the flange to
the duct.
(f) Carefully loosen each bolt of the flange to the duct. If excessive
resistance is encountered, apply more penetrating oil and allow the
bolts to soak for at least 15 minutes before proceeding.
NOTE: Ensure the proper size tool for the bolt head and do not force
the bolt excessively during the removal process.
(g) Remove the 12 bolts (75-00-49, 02-252), with the bracket (75-00-49,
01-235 and the bracket (75-00-49, 01-240).
(h) Remove the HP stage 7 bleed valve air duct (75-00-49, 01-250) from the
flange.
(i) If a bolt was broken during the removal process, perform the following
steps:
(i) Remove broken bolts and/or studs by mechanical removal methods.
(ii) Drill a hole into the end of the broken bolt and/or stud. Refer
to the tool manufacturer's instructions for the correct size
drill.
(iii) Put an extraction tool in to remove the broken bolt.
(iv) Tap the threads if necessary to clean or chase the threads.
(v) Examine the threads for damage or an oversize condition.
(j) If required, replace any inserts per Aircraft Maintenance ManualR TASK
70-35-26-300-010.
D. Install the turning tool and the borescope
(1) Install the turning tool to the accessory gearbox in accordance with the
manufacturer's operating instructions. Install the V2500 A1 software
module on the control unit, set the HP compressor rotation speed to the
slowest (10 minutes per revolution). Set the HP compressor stage to HPC8
and engage continuous rotation mode. (Refer to the Aircraft Maintenance
Manual,
R
R TASK 72-00-00-480-010).
OR
V2500−ENG−72−0615
Page 15
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 18

(2) Install the hand turning tool to the accessory gearbox (Refer to the
Aircraft Maintenance Manual,R TASK 72-00-00-860-010).
CAUTION: IF MATERIAL IS MISSING FROM THE CERAMIC LINER, LIFT THE PROBE OFF THE
LINER DURING INSPECTION TO PREVENT DAMAGE TO THE PROBE.
(3) Access the liner through the HP compressor Stage 7C bleed valve manifold
aperture on the left side of the engine (Refer to Figures 2 and 3). Insert
the flexible borescope and position between the stage seven stator vanes
to look down on the surface of the stage seven liner (Refer to Figure 3).
Make sure the borescope is clear of the stage 8 rotor blades and use the
turning tool to rotate the compressor one full revolution. Visually
examine the ceramic liner for any missing material, which could damage the
ultrasonic probe during the inspection rotationR and any staining or
indications of axial cracking (Refer to Figure 4).R A wear line on the
liner may be visible at the trailing edge of the stators, this is the
approximate seating position of the ultrasonic probe and particular
attention should be paid to this area around the circumference of the disc
(Refer to Figure 17).
NOTE: If staining or indications of axial cracking is found, contact the
local IAE office for further guidance before continuing.
R
R
NOTE: Missing stage 7-8 liner material directly underneath the path of
the probe may cause damage to the probe, requiring the probe to be
lifted off the liner during inspection. If liner loss under the
path of the probe is found, this must be noted on the
Accomplishment Proforma, as well as the percentage of the
circumference which was not ultrasonically inspected. If damage is
detected on the pre-inspection assessment, the borescope should be
inserted during the ultrasonic inspection to monitor the liner
during rotation.
R
R
R
R
R
R
R
R
R
NOTE: The borescope inspection for liner material loss is required to
ensure clearance of the rotor path for the ultrasonic probe. This
is recorded for information only, and does not need to be stamped
off as part of the formal accomplishment records. TheR results of
the borescope inspection for liner cracks or staining determine
further engine serviceability.
E. Calibrate the ultrasonic equipment
Range 28 mm (nominal)
Material velocity 3100 m/s
Delay 0.00 micro seconds
Frequency Selectable in the 5.0 MHz
range
Damping 50 Ohms
Rectify Full
Pulser Single crystal
V2500−ENG−72−0615
Page 16
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 19

Gate position 4.0 - 6.0 timebase position
NOTE: 1. The nominal settings above are for a USN 52 or equivalent flaw
detector to achieve approximateR signal timebase positions.
Alternative instruments may require different settings.
2. For calibration purposes the couplant feed manipulator should
be detached as described in F.(4) thru (7) in REVERSE order.
3. Care should be taken to keep the two working standards
IAE2R19854 and IAE2R19860 separate.
(1) Attach the lead to the manipulator/flaw detector, apply the distilled or
de-ionised water and position the probe (IAE2R19865) on to the working
standard (IAE2R19854) (Refer to Figure 5).
(2) Position the probe on the working standard with the flat face on the
working standard and the probe mounting screw facing the working standard.
The 0.04 in. long by 0.02 in. deep (1,0 mm l by 0,5 mm) EDM target is
located in the center of the base of the working standard (Refer to Figure
5).
NOTE: 1. If calibration is carried out with the working standard in
contact with a secondary surface, excessive couplant on the
working surface and EDM target surface, may allow transfer of
sound into the secondary surface. This can result in a weak
signal and incorrect calibration.
2. During calibration make sure that the probe is flat down on the
two contact faces of the working standards. Failure to do so
can result in incorrect calibration.
3. Make sure that the probe is positioned correctly on the working
standard and the reflected signal is not from the corner of the
block.
(3) With the probe positioned on the working standard (Refer to Figure 5),
identify the response from the EDM target at half skip distance. Maximize
the signal response to achieve 70 percent Full Screen Height (FSH) and
adjust the range control to position the EDM target signal at five on the
timebase. (Refer to Figure 6).
(4) Position the gate between the 4.0 and 6.0 divisions on the timebase and
set the alarm threshold level at 40 percent FSH.
V2500−ENG−72−0615
Page 17
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 20

F. Install the manipulator and ultrasonic probe (IAE2R19865) into the engine
CAUTION: DUE TO THE SIMILARITY BETWEEN THE INNER AND OUTER DIAMETER INSPECTION
TOOLS,R CARE MUST BE TAKEN TO ENSURE THE CORRECT PROBE AND WORKING
STANDARD HAVE BEEN SELECTED FOR THE RELEVANT INSPECTION.
(1) Position the distilled or de-ionised water container at a suitable
position on the engine. Make sure the container is supported above the
probe position. Attach the end of the water supply tube to the connector
on the rear of the manipulator. Open the valve on the water container and
make sure that water flows from the probe face with no sign of air
bubbles. When water flows from the probe, close the valve on the water
container.
(2) Before installing the manipulator/probe into the engine, make sure all
parts are secure. Make sure the attachment bolt for the ultrasonic probe
is secure, the spring is not bent and the cable is not damaged. Make sure
the water tube is removed from the manipulator assembly to allow the probe
to be inserted into the engine.
R
R
R
NOTE: Figure 7 shows the component parts of the probe assembly. Figure 8
shows the fully assembled probe and couplant feed tube correctly
assembled.
CAUTION: DO NOT APPLY FORCE TO THE MANIPULATOR OR DAMAGE MAY OCCUR TO THE
PROBE AND ENGINE.
(3) Use CoMat 10-058 to lightly oil the threads of the mounting bolts.
Position the probe manipulator arm to the forward side of the HP
compressor bleed valve port with the manipulator lock plate closed. Make
sure that the probe arm is installed to the correct bleed valve aperture
(Refer to Figure 9). Install the probe into the HP compressor case until
it contacts the ceramic liner. Slide the manipulator mount plate up to the
flange of the bleed valve. Hold the mount plate in contact with the flange
of the bleed valve and install the bolts by hand. Make sure the probe
manipulator assembly is free to move and tighten the bolts.
NOTE: When correctly installed, the probe manipulator assembly should be
able to slide freely in the mount plate and be able to make contact
with the liner.
(4) Open the manipulator lock plate and carefully install the couplant
manipulator into the same aperture and above the probe manipulator.
(5) Make sure that the couplant arm is correctly installed into the mount
plate groove and close the lock plate.
(6) Retract the tension spring lock plate until it can be installed over the
couplant arm mount boss (Refer to Figure 10).
V2500−ENG−72−0615
Page 18
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 21

(7) Make sure the probe and couplant arms are contacting the ceramic liner and
tighten the spring clamp.
(8) Connect the couplant feed system to the couplant feed manipulator.
NOTE: Figure 11 shows the ultrasonic probe manipulator assembly correctly
installed on the engine.
Make sure that the couplant feed manipulator is not mounted forward of the
probe, this will prevent reliable contact with the liner. When the
couplant feed tube and probe manipulator are correctly aligned, the
assembly is correctly installed.
G. Inspect the disc
(1) Open the water couplant valve and turn the HP compressor in a clockwise
direction until the probe is positioned between the two locking nuts of
the stage 7R locking blades (Refer to Figure 29). Apply light inward
pressure and make sure the probe is coupled with the liner by watching the
flaw detector timebase response. Withdraw the probe manipulator assembly
slightly and watch the change in timebase display when the probe is not
coupled. Return the probe to the coupled position.
NOTE: Water levels in the container must be monitored throughout the
inspection. If the container is found to be empty during the
inspection, the container must be refilled and the inspection
repeated.
R
R
R
R
(2) When the probe is coupled, zero the turning tool counter number datum and
begin the inspection. If the HP compressor is being turned manually, use a
borescope to locate a datum feature that can be used to confirm a complete
rotation of the drum.
NOTE: 1. The flaw detector should be monitored for signals that move
along the timebase in the gated area. Any ultrasonic responses
that break the alarm gate, will cause the engine to be rejected
(Refer to Figure 6).
R
R
R
R
2. During inspection monitor the distilled or de-ionised water
level, replenish as necessary.
R
R
(3) The flaw detector should be monitored for signals that move along the
timebase in the gated area. Any ultrasonic responses that break the alarm
gate, will cause the engine to be rejected (Refer to Figure 12).R
(4) Cracks that have developed on the inner surface of the disc will appear
(maximize)R within the gate on the timebase at half skip distance (Refer to
Figure 12).R
(5) Inspect the full circumference of the disc, if the ceramic liner allows.R
V2500−ENG−72−0615
Page 19
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 22

(6) If turning tool is used, record the amplitude and timebase position
indications over the threshold. Record the degree position on the
accomplishment proforma.
R
R
R
CAUTION: LIFT THE PROBE CLEAR OF THE CERAMIC LINER BEFORE YOU REVERSE THE
DIRECTION OF THE HP COMPRESSOR, TO PREVENT DAMAGE TO THE PROBE.
(7) If the probe 'picks up' or 'chatters' when the HP compressor is rotated in
a clockwise direction, Rotate the HP compressor in a counterclockwise
direction and repeat the inspection.
NOTE: 1. It is expected that there may be differences in signals when
the HP compressor is rotated in different directions. This is
because the direction of rotation changes the way the probe
sits on the liner. Additionally, the water comes in from one
direction only, which affects the function of the couplant, It
is recommended not to change the direction of rotation during
an inspection pass.
2. Missing stage 7 liner directly underneath the path of the probe
may cause damage to the probe, requiring the probe to be lifted
off the liner during inspection. If liner loss under the path
of the probe is found, this must be noted on the Accomplishment
Proforma, as well as the percentage of the circumference which
was not ultrasonically inspected. If damage is detected on the
pre-inspection assessment, the borescope should be inserted
during the ultrasonic inspection to monitor the liner during
rotation.
3. The borescope inspection for liner material loss is required to
ensure clearance of the rotor path for the ultrasonic probe.
This is recorded for information only, and does not need to be
stamped off as part of the formal accomplishment records. the
results of the borescope inspection for liner cracks or
staining determine further engine serviceability.
H. Remove the probe manipulator assembly from the engine
(1) After the inspection is complete, close the water valve and remove the
water supply tube from the couplant manipulator assembly. Slacken the
manipulator lock plate screw and spring clamp screw, remove the couplant
manipulator assembly from the bleed valve aperture.
CAUTION: DO NOT USE EXCESSIVE FORCE TO REMOVE THE PROBE MANIPULATOR ASSEMBLY
FROM THE ENGINE.
(2) Close the lock plate and remove the flange mount bolts. Carefully remove
the probe manipulator assembly from the engine.
(3) Make sure all parts of the probe manipulator assembly are present and
undamaged.
V2500−ENG−72−0615
Page 20
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 23

I. Make a check of the ultrasonic equipment calibration
(1) Make a check of the calibration of the ultrasonic equipment after the
inspection is completed. Carry out the check in accordance with paragraph
3.E. (1) to (3). If the calibration is under sensitive by more than 3dB,
re-calibrate the ultrasonic equipment and carry out an inspection of the
disc again.
J. Accept and reject criteria
(1) Any ultrasonic responseR in the gated area above or at the amplitude of 40
percent FSHR - reject the engine.
(2) Any ultrasonic response inR the gated area below the amplitude of 40
percent FSHR - accept.
K. General
Use the new inspection kit IAE2R19882 or the old inspection kit IAE2R19869 to
carry out an ultrasonic inspection on the inner diameter of the HP compressor
stage 8 disc adjacent to the 7-8 EB weld land.
NOTE: In order to reduce the potential for multiple-engine in-flight shutdown,
power loss, or other anomaly due to maintenance error, IAE recommends
that Operators avoid performing maintenance on multiple engines
installed on the same aircraft at the same time. If it is not possible
to avoid maintenance on more than one engine of an aircraft at the same
time, IAE recommends that additional controls are applied in order to
ensure that maintenance tasks have been completed as defined.
WARNING: YOU MUST BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE
ENGINE IS STOPPED. THE ENGINE PARTS CAN STAY HOT FOR ALMOST ONE HOUR.
WARNING: DO NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE
AN INJURY.R
(1) Obey all the WARNINGS and CAUTIONS in the procedures that are referred to.
(2) Consumable Materials
(a) Refer to the table that follows:
MATERIAL NO. DESIGNATION
V01-201R Distilled or De-ionised water
V10-058R Penetrating Oil
For the details of the consumable materials given in the table above,
refer to the Aircraft Maintenance Manual,R TASK 70-30-00-918-010.
V2500−ENG−72−0615
Page 21
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 24

(3) Tools and Equipment
(a) Refer to the table that follows:
ITEM DESCRIPTION TOOL NUMBER
(a) Inspection kit contains the inner diameter
location inspection kit of item (b) in this
table and the outer diameter location
inspection kit of item (b) of the table in
section 3.A.(3)(a) of this Non-Modification
Service Bulletin.
OR
IAE2R19882
(b) Inner diameter location inspection kit
*(contains items (c) to (g)
IAE2R19869
(c) Ultrasonic probe manipulator assembly IAE2R19870
(d) Couplant feed manipulator IAE2R19871
(e) Couplant feed system IAE2R19807
(f) Working standard IAE2R19860
(g) MCX/BNC lead IAE2R19755
(h) Ultrasonic flaw detector, frequency
selectable in the 5.0 MHz range with
audible/visual electronic alarm gate
Not supplied
(i) 4 to 6 mm flexible borescope kit with image
capture capability
Not supplied
(j) Turning tool (if applicable) Not supplied
(k) Bolts (2 off) AS48516 or
4W0170
R
R
not supplied
(l) Washers to fit item (k) Not supplied
NOTE: 1. The lead for the ultrasonic probe is supplied with a BNC
connector installed. An adaptor may be required if
alternative equipment is used.
2. The compressor can be turned manually, but an electronic
turning tool is recommended to perform the inspection.
3. Care should be taken to keep the two working standards
IAE2R19854 and IAE2R19860 separate.
R
R
L. Calibrate the ultrasonic equipment
Range 59 mm (nominal)
Material velocity 3100 m/s
Delay 0.00 micro seconds
Frequency Selectable in the 5.0 MHz
range
Damping 50 Ohms
Rectify Fullwave
Pulser Single crystal
V2500−ENG−72−0615
Page 22
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 25

Gate position 3.0 - 8.0 timebase position
NOTE: 1. The nominal settings above are for a USN 52 or equivalent flaw
detector to achieve signal timebase positions. Alternative
instruments may require different settings.
2. For calibration purposes the couplant feed manipulator should
be detached as described in M.(4) thru (7) in REVERSE order.
3. Care should be taken to keep the two working standards
IAE2R19854 and IAE2R19860 separate.
(1) Attach the lead to the manipulator/flaw detector, apply the distilled or
de-ionised water and position the probe (IAE2R19870) on to the working
standard (IAE2R19860) (Refer to Figure 5).
(2) Position the probe on the working standard with the flat face on the
working standard and the probe mounting screw facing the working standard.
Make sure the attachment bolt for the ultrasonic probe is secure, the
spring is not bent and the cable is not damaged.
NOTE: 1. If calibration is carried out with the working standard in
contact with a secondary surface, excessive couplant on the
working surface and EDM target surface, may allow transfer of
sound into the secondary surface. This can result in a weak
signal and incorrect calibration.
2. During calibration make sure that the probe is flat down on the
two contact faces of the working standards. Failure to do so
can result in incorrect calibration.
3. Make sure that the probe is positioned correctly on the working
standard and the reflected signal is not from the corner of the
block.
(3) With the probe positioned on the working standard (Refer to Figure 5),
identify the response from the EDM target at half skip distance. Maximize
the signal response to achieve 70 percent Full Screen Height (FSH) and
adjust the range control to position the EDM target signal at five on the
timebase. (Refer to Figure 6).
(4) Position the gate between the 3.0 and 8.0 divisions on the timebase and
set the alarm threshold level at 30 percent FSH for HP compressor drum P/N
6A8236, 6A8318, 6B1401R and 6B1403. For all other HP compressor drum P/Ns
set the alarm threshold level at 55 percent FSH (Refer to Figure 6).
V2500−ENG−72−0615
Page 23
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 26

M. Install the manipulator and ultrasonic probe (IAE2R19870) into the engine
CAUTION: DUE TO THE SIMILARITY BETWEEN THE INNER AND OUTER DIAMETER INSPECTION
TOOLS,R CARE MUST BE TAKEN TO ENSURE THE CORRECT PROBE AND WORKING
STANDARD HAVE BEEN SELECTED FOR THE RELEVANT INSPECTION.
(1) Position the distilled orR de-ionised water container at a suitable
position on the engine. Make sure the container is supported above the
probe position. Attach the end of the water supply tube to the connector
on the rear of the manipulator. Open the valve on the water container and
make sure that water flows from the probe face with no sign of air
bubbles. When water flows from the probe, close the valve on the water
container.
(2) Before installing the manipulator/probe into the engine, make sure all
parts are secure. Make sure the attachment bolt for the ultrasonic probe
is secure, the spring is not bent and the cable is not damaged. Make sure
the water tube is removed from the manipulator assembly to allow the probe
to be inserted into the engine.
R
R
R
NOTE: Figure 7 shows the component parts of the probe assembly. Figure 8
shows the fully assembled probe and couplant feed tube correctly
assembled.
CAUTION: DO NOT APPLY FORCE TO THE MANIPULATOR OR DAMAGE MAY OCCUR TO THE
PROBE AND ENGINE.
(3) Use CoMat 10-058 to lightly oil the threads of the mounting bolts.
Position the probe manipulator arm to the forward side of the HP
compressor bleed valve port with the manipulator lock plate closed. Make
sure that the probe arm is installed to the correct bleed valve aperture
(Refer to Figure 9). Install the probe into the HP compressor case until
it contacts the ceramic liner. Slide the manipulator mount plate up to the
flange of the bleed valve. Hold the mount plate in contact with the flange
of the bleed valve and install the bolts by hand. Make sure the probe
manipulator assembly is free to move and tighten the bolts.
NOTE: When correctly installed, the probe manipulator assembly should be
able to slide freely in the mount plate and be able to make contact
with the liner.
(4) Open the manipulator lock plate and carefully install the couplant
manipulator into the same aperture and above the probe manipulator.
(5) Make sure that the couplant arm is correctly installed into the mount
plate groove and close the lock plate.
(6) Retract the tension spring lock plate until it can be installed over the
couplant arm mount boss (Refer to Figure 10).
V2500−ENG−72−0615
Page 24
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 27

(7) Make sure the probe and couplant arms are contacting the ceramic liner and
tighten the spring clamp.
(8) Connect the couplant feed system to the couplant feed manipulator.
NOTE: Figure 11 shows the ultrasonic probe manipulator assembly correctly
installed on the engine.
Make sure that the couplant feed manipulator is not mounted forward
of the probe, this will prevent reliable contact with the liner.
When the couplant feed tube and probe manipulator are correctly
aligned, the assembly is correctly installed.
N. Inspect the disc
(1) Open the water couplant valve and turn the HP compressor in a clockwise
direction until the probe is positioned between the two locking nuts of
the stage 7R locking blades (Refer to Figure 29). Apply light inward
pressure and make sure the probe is coupled with the liner by watching the
flaw detector timebase response. Withdraw the probe manipulator assembly
slightly and watch the change in timebase display when the probe is not
coupled. Return the probe to the coupled position.
NOTE: Water levels in the container must be monitored through the
inspection. If the container is found to be empty during the
inspection, the container must be refilled and the inspection
repeated.
(2) When the probe is coupled, zero the turning tool counter number datum and
begin the inspection. If the HP compressor is being turned manually, use a
borescope to locate a datum feature that can be used to confirm a complete
rotation of the drum.
NOTE: 1. The flaw detector timebase signals must be constantly monitored
during the inspection, as no back-wall or geometry signals
appear on the timebase and loss of coupling could occur at any
time.
2. During inspection monitor the distilled or de-ionised water
level, replenish as necessary
(3) The flaw detector should be monitored for signals that move along the
timebase in the gated area. Any ultrasonic responses that break the alarm
gate, will cause the engine to be rejected (Refer to Figure 12).
(4) Cracks that have developed on the inner surface of the disc will appear
(maximize)R within the gate on the timebase at half skip distance. (Refer
to Figure 12).
(5) Inspect the full circumference of the disc, if the ceramic liner allows.R
V2500−ENG−72−0615
Page 25
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 28

(6) If turning tool is used, record the amplitude and timebase position
indications over the threshold. Record the degree position on the
accomplishment proforma.
R
R
R
CAUTION: LIFT THE PROBE CLEAR OF THE CERAMIC LINER BEFORE YOU REVERSE THE
DIRECTION OF THE HP COMPRESSOR, TO PREVENT DAMAGE TO THE PROBE.
(7) If the probe 'picks up' or 'chatters' when the HP compressor is rotated in
a clockwise direction, Rotate the HP compressor in a counterclockwise
direction and repeat the inspection.
NOTE: 1. It is expected that there may be differences in signals when
the HP compressor is rotated in different directions. This is
because the direction of rotation changes the way the probe
sits on the liner. Additionally, the water comes in from one
direction only, which affects the function of the couplant, It
is recommended not to change the direction of rotation during
an inspection pass.
2. Missing stage 7 liner directly underneath the path of the probe
may cause damage to the probe, requiring the probe to be lifted
off the liner during inspection. If liner loss under the path
of the probe is found, this must be noted on the Accomplishment
Proforma, as well as the percentage of the circumference which
was not ultrasonically inspected. If damage is detected on the
pre-inspection assessment, the borescope should be inserted
during the ultrasonic inspection to monitor the liner during
rotation.
3. The borescope inspection for liner material loss is required to
ensure clearance of the rotor path for the ultrasonic probe.
This is recorded for information only, and does not need to be
stamped off as part of the formal accomplishment records. the
results of the borescope inspection for liner cracks or
staining determine further engine serviceability.
O. Remove the probe manipulator assembly from the engine
(1) After the inspection is complete, close the water valve and remove the
water supply tube from the couplant manipulator assembly. Slacken the
manipulator lock plate screw and spring clamp screw, remove the couplant
manipulator assembly from the bleed valve aperture.
CAUTION: DO NOT USE EXCESSIVE FORCE TO REMOVE THE PROBE MANIPULATOR ASSEMBLY
FROM THE ENGINE.
(2) Close the lock plate and remove the flange mount bolts. Carefully remove
the probe manipulator assembly from the engine.
(3) Make sure all parts of the probe manipulator assembly are present and
undamaged.
V2500−ENG−72−0615
Page 26
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 29

P. Make a check of the ultrasonic equipment calibration
(1) Make a check of the calibration of the ultrasonic equipment after the
inspection is completed. Carry out the check in accordance with paragraph
3.L. (1) to (3). If the calibration is under sensitive by more than 3dB,
re-calibrate the ultrasonic equipment and carry out an inspection of the
disc again.
(2) If the calibration is satisfactory, disconnect the turning tool and remove
it from the engine
(a) Remove the turning tool from the accessory gearbox in accordance with
the manufacturer's operating instructions (Refer to the Aircraft
Maintenance Manual,R TASK 72-00-00-080-010).
OR
(b) Remove the hand turning tool from the accessory gearbox (Refer to the
Aircraft Maintenance Manual,R TASK 72-00-00-860-010).
NOTE: 1. All equipment including the probe manipulator assembly
water supply tube and the water bottle should be thoroughly
drained and dried before storing, to prevent corrosion.
R
R
R
2. Due to the similarity between the inner and outer diameter
inspection kits, care must be taken to ensure the correct
probes and working standards are replaced in the correct
storage cases. Part numbers of the individual tools are
marked on the case labels and on the tools.
R
R
R
R
R
Q. Accept and reject criteria
(1) For HP compressor drum P/N 6A8236, 6A8318, 6B1401R and 6B1403:
(a) Any ultrasonic responseR in the gated area above or at the amplitude of
30 percent FSHR - reject the engine.
(b) Any ultrasonic response inR the gated area below the amplitude of 30
percent FSHR - accept.
(2) For all other HP compressor P/Ns:
(a) Any ultrasonic response in the gated area above or at the amplitude of
55 percent FSH - reject the engine.
R
R
(b) Any ultrasonic response in the gated area below the amplitude of 55
percent FSH - accept.
R
R
V2500−ENG−72−0615
Page 27
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 30

R. Install the HP stage 7 bleed valve air duct on the left side of the engine.
(1) Install the HP stage 7 bleed valve air duct together with the HP
compressor stage 7 bleed valve
R
R
(a) Lubricate all threads and abutment faces of nuts and bolts with CoMat
10-077 (approved engine oil) and CoMat 10-094 (anti seize compound).R
(b) Hold the HP stage 7 bleed valve air duct (75-00-49, 01-250) in the
correct position on the HP compressor case and align the bolt holes.
(c) Install the 12 bolts (75-00-49, 01-252), with the bracket (75-00-49,
01-235) and the bracket (75-00-49, 01-240).
(d) Torque the twelve bolts (75-00-49, 01-252) to 85 to 105 lbf in. (10 to
12 Nm).
(e) Install the 'v' clamp (36-11-41, 01-100).
(f) Torque the coupling nut on 'v' clamp (36-11-14, 01-100) to 75 to 85
lbf in. (8,5 to 9,6 Nm). Use a soft faced hammer and tap around the
outside of the coupling.
(g) Torque the coupling nut again. Use the above procedure three more
times.
S. Make sure that the work area is clean and clear of tools, equipment and other
unwanted materials.
T. Close the access to the HP compressor stage 7 bleed valve aperture that is
installed on the left side of the engine
(1) Close the fan cowl doors (Refer to the Aircraft Maintenance Manual,
Chapter 71-13-00).
(2) Close both halves of the thrust reverser (Refer to the Aircraft
Maintenance Manual, Chapter 78-32-00).
(3) Activate the thrust reverser Hydraulic Control Unit (HCU) (Refer to the
Aircraft Maintenance Manual, Chapter 78-30-00).
(4) Do a idle leak check (Refer to the Aircraft Maintenance Manual, Chapter
71-00-00).
U. Recording Instructions
(1) A record of accomplishment is required. Complete a separate Accomplishment
Proforma for outer and inner diameter.
V2500−ENG−72−0615
Page 28
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 31

(2) Record the incorporation of Non-Modification Service Bulletin
V2500-ENG-72-0615R in the applicable engine records.
V2500−ENG−72−0615
Page 29
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 32

Part B - Applicable for V2500-A5 engines
V. General
Use the new inspection kit IAE2R19878 or the old inspection kit IAE2R19851R to
carry out an ultrasonic inspection on the outer diameter of the HP compressor
stage 8 disc adjacent to the stage 7-8 EB weld land.
NOTE: In order to reduce the potential for multiple-engine in-flight shutdown,
power loss, or other anomaly due to maintenance error, IAE recommends
that Operators avoid performing maintenance on multiple engines
installed on the same aircraft at the same time. If it is not possible
to avoid maintenance on more than one engine of an aircraft at the same
time, IAE recommends that additional controls are applied in order to
ensure that maintenance tasks have been completed as defined.
WARNING: YOU MUST BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE
ENGINE IS STOPPED. THE ENGINE PARTS CAN STAY HOT FOR ALMOST ONE HOUR.
WARNING: DO NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE
AN INJURY.R
(1) Obey all the WARNINGS and CAUTIONS in the procedures that are referred to.
(2) Consumable Materials
(a) Refer to the table that follows:
MATERIAL NO.R DESIGNATIONR
V01-201R Distilled or De-ionised waterR
V10-058R Penetrating OilR
V06-064R Fluorescent PenetrantR
V05-020R Waterproof Abrasive PaperR
V05-021R Waterproof Abrasive PaperR
V05-074R Aluminum Oxide Abrasive PaperR
For the details of the consumable materials given in the table above,
refer to the Aircraft Maintenance ManualR TASK 70-30-00-910-801.
(3) Tools and Equipment
(a) For inspection of the outer diameter location:
ITEM DESCRIPTION TOOL NUMBER
(a) Inspection kit contains the outer diameter
location inspection kit of item (b) in this
table and the inner diameter location
inspection kit of item (b) of the table in
section 3.AF.(3)(a) of this Non-Modification
Service Bulletin.
OR
IAE2R19878
V2500−ENG−72−0615
Page 30
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 33

(b) Outer diameter location inspection kit
*(contains items (c) to (f)
IAE2R19851R
(c) Ultrasonic probe manipulator assembly
contains 45 degree shear wave ultrasonic
inspection probe
IAE2R19852 or
IAE2R19879
(d) Couplant feed system IAE2R19807
(e) Outer diameter location working standard IAE2R19854
(f) MCX/BNC lead IAE2R19755
(g) Ultrasonic flaw detector, frequency
selectable in the 5.0 MHz range with
audible/visual electronic alarm gate
Not supplied
(h) Distilled or De-ionised water Not supplied
(i) Turning tool (if applicable) Not supplied
(j) 4 to 6 mm flexible borescope kit with image
capture capability
Not supplied
(k) 8 mm NC-centralising drill bit (90 degree
cutting angle, HSCO material, TiN coated)
Generic, eg
Forum #
4211506022 or
equivalent -
Not supplied
(l) Outer diameter location drilling guide tool IAE1R19877 or
IAE1R19861
(m) Bolts (2 off) AS48516 or
4W0170
R
R
not supplied
(n) Washers to fit item (m) Not supplied
(o) Vacuum cleaner and hose Not supplied
(p) Cloth Not supplied
(q) Hand-held electric drill Not supplied
(r) Penetrating oil Not supplied
(s)R Portable hand grinding equipmentR Not suppliedR
NOTE: 1. The lead for the ultrasonic probe is supplied with a BNC
connector installed. An adaptor may be required if
alternative equipment is used.
2. The compressor can be turned manually, but an electronic
turning tool is recommended to perform the inspection.
3. Care should be taken to keep the two working standards
IAE2R19854 and IAE2R19860 separate.
4. Drilling guide tool IAE1R19861 can be reworked to
IAE1R19877, for details contact your local IAE
Representive.
5. The outer diameter drilling guide tool number is identical
to the inner diameter location drilling guide tool number.
V2500−ENG−72−0615
Page 31
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 34

W. Get access to the HP compressor stage 7 bleed valve aperture that is installed
on the left side of the engine
(1) Deactivate the thrust reverser Hydraulic Control Unit (HCU) (Refer to the
Aircraft Maintenance Manual, Chapter 78-30-00).
(2) Open the applicable cowl doors (Refer to the Aircraft Maintenance Manual,R
Chapter 71-13-00).
(3) Open the applicable half of the thrust reverser (Refer to the Aircraft
Maintenance Manual, Chapter 78-32-00).
X. Remove the HP stage 7 bleed valve air duct from the left side of the engine.
(1) Remove the HP stage 7 bleed valve air duct together with the HP compressor
stage 7 bleed valve
R
R (Refer to Figure 1)
(a) Allow the engine to cool for at least two hours with the cowl doors
open.
(b) Apply the approved penetrating oil CoMat 10-058 before the removal of
threaded parts. Let the parts soak at least 15 minutes.
(c) Seal all openings to prevent contamination from unwanted materials.
(d) Remove the coupling that attaches the IP bleed check valve to the HP7
bleed valve/cabin air duct (Refer to the Aircraft Maintenance Manual,
Chapter 36-11-41).
(e) Carefully overcome the initial torque of each bolt of the flange to
the duct.
(f) Carefully loosen each bolt of the flange to the duct. If excessive
resistance is encountered, apply more penetrating oil and allow the
bolts to soak for at least 15 minutes before proceeding.
NOTE: Make sure you use the correct size tool for the bolt head and
do not force the bolt excessively during the removal process.
(g) Repeat step (f) until all bolts have been removed successfully.
(h) Remove the duct.
(i) If a bolt was broken during the removal process, perform the steps
that follow:
(i) Remove broken bolts and/or studs by mechanical removal methods.
(ii) Drill a hole into the end of the broken bolt and/or stud. Refer
to the tool manufacturer's instructions for the correct size of
drill.
V2500−ENG−72−0615
Page 32
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 35

(iii) Put an extraction tool into the drilled hole and lock into
position.
(iv) Turn the extraction tool to remove the broken bolt.
(v) Tap the threads if necessary to clean or chase the threads.
(vi) Examine the threads for damage or an oversize condition.
(j) If required, replace any inserts (Refer to the Aircraft Maintenance
Manual, Chapter 70-35-26).
(2) When using the new inspection kit, IAE2R19879 on engines with Pre SB
72-0263 standard HPC Rear Outer Cases (P/N, 6A4154 and 6A5495) the bleed
port flange may obstruct access of the drill and inspection probe. If this
occurs perform the rework that follows:
R
R
R
R
(a) Prepare inner free area of the bleed port by placing a clean cloth
such that no cutting debris can fall into the engine.
R
R
(b) Blend to create a recess in the rear outer case port flange.R
Remove minimum amount of material possible to enable access, do not
exceed the given limits. Use abrasive stones and papers to create the
recess ensuring a smooth finish and blend into adjacent areas is
achieved. Ensure all burrs and sharp edges are removed and the surface
finish is comparable to adjacent areas.
R
R
R
R
R
Use V05-020, V05-021 and/or V05-074 abrasive papers and portable hand
grinding equipment. Refer to Figures 14A and 14B.
R
R
CAUTION: NOTE THE MAXIMUM BLEND LIMITS DEFINED IN FIGURE 14B AND ENSURE
THEY ARE NOT EXCEEDED AS THIS CAN LEAD TO THE ENGINE BEING
REJECTED UPON INSPECTION.
R
R
R
(c) Locally clean and fluorescent penetrant inspect the blended area.
Refer to SPP TASK 70-23-05-230-010. Use CoMat V06-064 penetrant with a
brush. If cracks are found, reject the engine.
R
R
R
CAUTION: ENSURE THE ENGINE IS SUFFICIENTLY PROTECTED WITH THE CLOTH PLACED
IN STEP. (A) SO THAT NO SOLVENT OR PENETRANT CAN FALL INTO THE
ENGINE.
R
R
R
(d) Remove the cloth protecting the engine and wipe away any visible
debris. If available, use a vacuum cleaner and hose to remove any
further debris.
R
R
R
(e) Inspect the case flange to ensure the blend limits were not exceeded.
If the limits are exceeded, reject the engine.
R
R
V2500−ENG−72−0615
Page 33
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 36

(3) For engines which have HP compressor heat shield retainers (pre
V2500-ENG-72-0296) or heat shield retainers with heat shields (pre
V2500-ENG-72-0477), perform the rework that follows for probe access
(a) Prepare inner free area of the bleed port by placing a clean cloth
such that no cutting debris can fall into the engine.
(b) Attach the drilling guide tool IAE1R19861 or IAE1R19877 to one end of
the slotted hole with two bolts (AS48516)R and two washers as shown in
Figure 13.
(c) Insert an 8,00R mm (0.315 in.) drill bit into the drilling guide tool
and drill a hole until the second wall of the heat shield retainer is
penetrated (Figure 14 thru Figure 17).
(d) Remove the drill, loosen the bolts and slide the guide tool to the
other end of the slotted hole and repeat step (c).
(e) Repeat steps (c) and (d) between the previously drilled two holes,
until the entire opening is created as shown in Figure 15 thru Figure
17.
(f) Deburr and remove high material aroundR the corners of the opening
using mechanical tools untilR the probe can be inserted easily.
(g) Remove the cloth and wipe away any visible debris. If available, use a
vacuum cleaner and hose to remove any further debris.
Y. Install the HP system turning tool and the borescope
(1) Install the turning tool to the accessory gearbox in accordance with the
manufacturer's operating instructions (Olympus tool quoted). Install the
V2500 A5 software module on the control unit, set the HP compressor
rotation speed to the slowest (10 minutes per revolution). Set the HP
compressor stage to HPC8 and engage continuous rotation mode. (Refer to
the Aircraft Maintenance Manual,R TASK 72-00-00-480-010).
OR
(2) Install the hand turning tool to the accessory gearbox (Refer to the
Aircraft Maintenance Manual,R TASK 72-00-00-860-010).
V2500−ENG−72−0615
Page 34
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 37

CAUTION: IF MATERIAL IS MISSING FROM THE CERAMIC LINER, LIFT THE PROBE OFF THE
LINER DURING INSPECTION TO PREVENT DAMAGE TO THE PROBE.
(3) Access the liner through the HP compressor Stage 7C bleed valve manifold
aperture on the left side of the engine (Refer to Figure 16). Insert the
flexible borescope and position between the stage seven stator vanes to
look down on the surface of the stage seven liner (Refer to Figure 17 thru
Figure 19). Make sure the borescope is clear of the stage 8 rotor blades
and use the turning tool to rotate the compressor one full revolution.
Visually examine the ceramic liner for any missing material, which could
damage the ultrasonic probe during the inspection rotationR and any
staining or indications of axial cracking (Refer to Figure 4).R A wear line
on the liner may be visible at the trailing edge of the stators, this is
the approximate seating position of the ultrasonic probe and particular
attention should be paid to this area around the circumference of the disc
(Refer to Figure 17).
NOTE: If staining or indications of axial cracking is found, contact the
local IAE office for further guidance before continuing.
R
R
NOTE: Missing stage 7-8R liner material directly underneath the path of
the probe may cause damage to the probe, requiring the probe to be
lifted off the liner during inspection. If liner loss under the
path of the probe is found, this must be noted on the
Accomplishment Proforma, as well as the percentage of the
circumference which was not ultrasonically inspected. If damage is
detected on the pre-inspection assessment, the borescope should be
inserted during the ultrasonic inspection to monitor the liner
during rotation.
NOTE: The borescope inspection for liner material loss is required to
ensure clearance of the rotor path for the ultrasonic probe. This
is recorded for information only, and does not need to be stamped
off as part of the formal accomplishment records. TheR results of
the borescope inspection for liner cracks or staining determine
further engine serviceability.
Z. Calibrate the ultrasonic equipment
Range 28 mm (nominal)
Material velocity 3100 m/s
Delay 0.00 micro seconds
Frequency Selectable in the 5.0 MHz
range
Damping 50 Ohms
Rectify Full
Pulser Single crystal
V2500−ENG−72−0615
Page 35
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 38

Gate position 4.0 - 6.0 time base position
NOTE: 1. The nominal settings above are for a USN 52 or equivalent flaw
detector to achieve approximate signal timebase positions.
Alternative instruments may require different settings.
R
R
R
2. Care should be taken to keep the two working standards
IAE2R19854 and IAE2R19860 separate.
R
R
(1) Attach the lead to the manipulator/flaw detector, apply the distilled or
de-ionised water and position the probe (IAE2R19852) on to the working
standard (Refer to Figure 20).
(2) With the flat face of the probe seated on the rear face of the working
standard and the chamfered corners outward facing, position the probe on
the working standard (Refer to Figure 20). The 1.0 mm long by 0.50 mm deep
EDM notch is located in the center of the base of the working standard.
NOTE: 1. If calibration is carried out with the working standard in
contact with a secondary surface, excessive couplant on the
working surface and EDM target surface, may allow transfer of
sound into the secondary surface. This can result in a weak
signal and incorrect calibration.
2. During calibration make sure that the probe is flat down on the
two contact faces of the working standards. Failure to do so
can result in incorrect calibration.
3. Make sure that the probe is positioned correctly on the working
standard and the reflected signal is not from the corner of the
block.
(3) With the probe positioned on the working standard (Refer to Figure 20),
identify the response from the EDM target at half skip distance. Maximize
the signal response to achieve 70 percent Full Screen Height (FSH) and
adjust the range control to position the EDM target signal at five on the
timebase. (Refer to Figure 6).
(4) Position the gate between the 4.0 and 6.0 divisions on the time base and
set the alarm threshold level at 40 percent FSH.
AA.Install the manipulator (IAE2R19852 or IAE2R19879) and ultrasonic probe into
V2500−ENG−72−0615
Page 36
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 39

the engine
CAUTION: DUE TO THE SIMILARITY BETWEEN THE INNER AND OUTER DIAMETER INSPECTION
TOOLS,R CARE MUST BE TAKEN TO ENSURE THE CORRECT PROBE AND WORKING
STANDARD HAVE BEEN SELECTED FOR THE RELEVANT INSPECTION.
(1) Position the distilled or de-ionised water container at a suitable
position on the engine. Make sure the container is supported above the
probe position. Attach the end of the water supply tube to the connector
on the rear of the manipulator. Open the valve on the water container and
make sure that water flows from the probe face with no sign of air
bubbles. When water flows from the probe, close the valve on the water
container.
(2) Before installing the manipulator/probe into the engine, make sure all
parts are secure. Make sure the attachment bolt for the ultrasonic probe
is secure, the spring is not bent and the cable is not damaged. Make sure
the water tube is removed from the manipulator assembly to allow the probe
to be inserted into the engine.
R
R
R
NOTE: 1. Two standards of bleed air slots may be found on engines. The
current modification standard has longer elongated slots (Refer
to Figure 26) however a number of engines have an earlier
modification standard with smaller square slots (Refer to
Figure 27). The gaps between the stator platforms are
identical; however, the larger slot allows more freedom to
allow the probe to fit easily into the gap between the stators.
Installing the probe into the smaller slot is more difficult
due to the smaller space available; in this case, the probe
face initially contacts the corner of the lower stator platform
(Refer to figure 27).
2. To install the probe to the smaller slot, first angle the head
of the probe upwards a few degrees by gently rotating the probe
head on the attachment bolt. Holding the manipulator as low as
possible during entry, will allow the probe to slide upwards as
it enters the slot avoiding the corner of the stator. When
installed, the manipulator assembly should be pushed on to the
liner to ensure contact and to center the probe.
3. During withdrawal, the probe will contact the inner surface of
the stator platform preventing withdrawal. By applying gentle
pressure to the manipulator, and again adjusting the probe head
angle, whilst the probe is still in the engine, the probe will
be able to be withdrawn. Excessive force must not be used
during removal.
V2500−ENG−72−0615
Page 37
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 40

(3) Use CoMat 10-058 to lightlyR oil the threads of the mounting bolts. Offer
the probe to the forward side of the HP compressor bleed valve port (Refer
to Figure 21) through the bleed slot adjacent to the flat-headed D bolt.
Carefully allow the probe to enter the HP compressor casing until it
contacts the ceramic liner. Carefully slide the manipulator mounting plate
up to the bleed valve flange. Manually screw the bolts into the bolt holes
ensuring the mounting plate remains in contact with the bleed valve flange
and the probe manipulator assembly is free to move. Tighten the bolts
alternately whilst checking the probe manipulator assembly remains free to
move.
NOTE: Do not force the manipulator or damage may occur to the probe and
engine.
If the probe is difficult to insert, more material should be
removed from the first and second walls of the heatshield retainer.
R
R
(4) When correctly installed, the probe manipulator assembly should be able to
slide freely in the mounting block and be able to make contact with the
liner. Figure 22 shows the manipulator assembly correctly installed to the
engine.
AB.Inspect the disc
(1) Open the water couplant valve fully and turn the HP compressor in a
clockwise direction until the probe is positioned between the two locking
nuts of the stage 7R locking blades (Refer to Figure 29). Apply light
inward pressure and make sure the probe is coupled with the liner by
watching the flaw detector time base response. Withdraw the probe
manipulator assembly slightly and watch the change in time base display
when the probe is not coupled. Return the probe to the coupled position.
NOTE: Water levels in the container must be monitored through the
inspection. If the container is found to be empty during the
inspection, the container must be refilled and the inspection
repeated.
(2) When the probe is coupled, zero the turning tool counter number datum and
begin the inspection. If the HP compressor is being turned manually, use a
borescope to locate a datum feature that can be used to confirm a complete
rotation of the drum.
NOTE: 1. The flaw detector should be monitored for signals that move
along the timebase in the gated area. Any ultrasonic responses
that break the alarm gate (40 percent)R will cause the engine to
be rejected (Refer to Figure 25).
2. During inspection monitor the distilled or de-ionised water
level, replenish as necessary.
V2500−ENG−72−0615
Page 38
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 41

(3) The flaw detector should be monitored for signals that move along the
timebase in the gated area. Any ultrasonic responses that break the alarm
gate (40 percent),R will cause the engine to be rejected (Refer to Figure
25).
(4) Cracks that have developed on the inner surface of the disc will appear
(maximize)R within the gate on the time base at half skip distance (Refer
to Figure 25).
(5) Inspect the full circumference of the disc, if the ceramic liner allows.R
(6) If turning tool is used, record the amplitude and timebase position
indications over the threshold. Record the degree position on the
accomplishment proforma.
R
R
R
CAUTION: LIFT THE PROBE CLEAR OF THE CERAMIC LINER BEFORE YOU REVERSE THE
DIRECTION OF THE HP COMPRESSOR, TO PREVENT DAMAGE TO THE PROBE.
(7) If the probe 'picks up' or 'chatters' when the HP compressor is rotated in
a clockwise direction, Rotate the HP compressor in a counterclockwise
direction and repeat the inspection.
NOTE: 1. It is expected that there may be differences in signals when
the HP compressor is rotated in different directions. This is
because the direction of rotation changes the way the probe
sits on the liner. Additionally, the water comes in from one
direction only, which affects the function of the couplant, It
is recommended not to change the direction of rotation during
an inspection pass.
2. Missing stage 7 liner directly underneath the path of the probe
may cause damage to the probe, requiring the probe to be lifted
off the liner during inspection. If liner loss under the path
of the probe is found, this must be noted on the Accomplishment
Proforma, as well as the percentage of the circumference which
was not ultrasonically inspected. If damage is detected on the
pre-inspection assessment, the borescope should be inserted
during the ultrasonic inspection to monitor the liner during
rotation.
3. The borescope inspection for liner material loss is required to
ensure clearance of the rotor path for the ultrasonic probe.
This is recorded for information only, and does not need to be
stamped off as part of the formal accomplishment records. the
results of the borescope inspection for liner cracks or
staining determine further engine serviceability.
V2500−ENG−72−0615
Page 39
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 42

AC.Remove the probe manipulator assembly from the engine
(1) AfterR completion of the inspection, close the water valve and remove the
water supply tube from the manipulator. Undo the bolts and carefully ease
the manipulator from the bleed valve port.
CAUTION: DO NOT USE EXCESSIVE FORCE TO REMOVE THE PROBE MANIPULATOR ASSEMBLY
FROM THE ENGINE.
(2) Close the lock plate and remove the flange mount bolts. Carefully remove
the probe manipulator assembly from the engine.
(3) Make sure all parts of the probe manipulator assembly are present and
undamaged.
AD.Make a check of the ultrasonic equipment calibration
(1) Make a check of the calibration of the ultrasonic equipment after the
inspection is completed. Carry out the check in accordance with paragraph
3.Z. (1) to (4). If the calibration is under sensitive by more than 3dB,
re-calibrate the ultrasonic equipment and carry out an inspection of the
disc again.
AE.Accept and reject criteria
(1) Any ultrasonic response in the gated area above or at the amplitude of 40
percent FSH - reject the engine.
R
R
(2) Any ultrasonic response in the gated area below the amplitude of 40
percent FSH - accept.
R
R
AF.General
Use the new inspection kit IAE2R19878 or the old inspection kit IAE2R19858 to
carry out an ultrasonic inspection on the inner diameter of the HP compressor
stage 8 disc adjacent to the stage 7-8 EB weld land.
NOTE: In order to reduce the potential for multiple-engine in-flight shutdown,
power loss, or other anomaly due to maintenance error, IAE recommends
that Operators avoid performing maintenance on multiple engines
installed on the same aircraft at the same time. If it is not possible
to avoid maintenance on more than one engine of an aircraft at the same
time, IAE recommends that additional controls are applied in order to
ensure that maintenance tasks have been completed as defined.
V2500−ENG−72−0615
Page 40
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 43

WARNING: YOU MUST BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE
ENGINE IS STOPPED. THE ENGINE PARTS CAN STAY HOT FOR ALMOST ONE HOUR.
WARNING: DO NOT TOUCH HOT PARTS WITHOUT APPLICABLE GLOVES. HOT PARTS CAN CAUSE
AN INJURY.R
(1) Obey all the WARNINGS and CAUTIONS in the procedures that are referred to.
(2) Consumable Materials
(a) Refer to the table that follows:
MATERIAL NO. DESIGNATION
V01-201R Distilled or De-ionised water
V10-058R Penetrating Oil
For the details of the consumable materials given in the table above,
refer to the Aircraft Maintenance Manual (AMM) TASK 70-30-00-918-010.
(3) Tools and Equipment
(a) Refer to the table that follows:
ITEM DESCRIPTION TOOL NUMBER
(a) Inspection kit contains the inner diameter
location inspection kit of item (b) in this
table and the outer diameter location
inspection kit of item (b) of the table in
section 3.V.(3)(a) of this Non-Modification
Service Bulletin.
OR
IAE2R19878
(b) Inner diameter location inspection kit
*(contains items (c) to (f)
IAE2R19858
(c) Ultrasonic probe manipulator assembly
contains 45 degree shear wave ultrasonic
inspection probe
IAE2R19859 or
IAE2R19880
(d) Couplant feed system IAE2R19807
(e) Inner diameter location working standard IAE2R19860
(f) MCX/BNC lead IAE2R19755
(g) Ultrasonic flaw detector, frequency
selectable in the 5.0 MHz range with
audible/visual electronic alarm gate
Not supplied
(h) Distilled or De-ionised water Not supplied
(i) Turning tool (if applicable) Not supplied
(j) 4 to 6 mm flexible borescope kit with image
capture capability
Not supplied
(k) 8 mm NC-centralising drill bit (90 degree
cutting angle, HSCO material TiN coated)
Generic, eg
Forum #
4211506022 or
equivalent -
Not supplied
V2500−ENG−72−0615
Page 41
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 44

(l) Inner diameter location drilling guide tool IAE1R19877 or
IAE1R19861
(m) Bolts (2 off) AS48516 or
4W0170
R
R
not supplied
(n) Washers to fit item (m) Not supplied
(o) Vacuum cleaner and hose Not supplied
(p) Cloth Not supplied
(q) Hand-held electric drill Not supplied
(r) Penetrating oil Not supplied
(s)R Portable hand grinding equipmentR Not suppliedR
NOTE: 1. The lead for the ultrasonic probe is supplied with a BNC
connector installed. An adaptor may be required if
alternative equipment is used.
2. The compressor can be turned manually, but an electronic
turning tool is recommended to perform the inspection.
3. Care should be taken to keep the two working standards
IAE2R19854 and IAE2R19860 separate.
AG.Calibrate the ultrasonic equipment
Range 59mm (nominal)
Material velocity 3100 m/s
Delay 0.00 micro seconds
Frequency Selectable in the 5.0 MHz
range
Damping 50 Ohms
Rectify Full wave
Pulser Single crystal
Gate position 3.0 - 8.0 timebase position
NOTE: 1. The nominal settings above are for a USN 52 or equivalent flaw
detector to achieve approximate signal timebase positions.
Alternative instruments may require different settings.
R
R
R
2. Care should be taken to keep the two working standards
IAE2R19854 and IAE2R19860 separate.
R
R
(1) Attach the lead to the manipulator/flaw detector, apply the distilled or
de-ionised water and position the probe (IAE2R19859 or IAE2R19880) on to
the working standard (IAE2R19860) (Refer to Figure 24).
V2500−ENG−72−0615
Page 42
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 45

(2) With the flat face of the probe seated on the rear face of the working
standard and the chamfered corners outward facing, position the probe on
the working standard approximately 10.00 mm from the end as shown (Refer
to Figure 24). The EDM target is located on the lower rear edge of the
working standard.
NOTE: 1. If calibration is carried out with the working standard in
contact with a secondary surface, excessive couplant on the
working surface and EDM target surface, may allow transfer of
sound into the secondary surface. This can result in a weak
signal and incorrect calibration.
2. During calibration make sure that the probe is flat down on the
two contact faces of the working standards. Failure to do so
can result in incorrect calibration.
3. Make sure that the probe is positioned correctly on the working
standard and the reflected signal is not from the corner of the
block.
(3) With the probe positioned on the working standard (Refer to Figure 24),
identify the response from the EDM target at half skip distance. Maximize
the signal response to achieve 70 percent Full Screen Height (FSH) and
adjust the range control to position the EDM target signal at five on the
timebase. (Refer to Figure 25).
(4) Position the gate between the 3.0 and 8.0 divisions on the time base and
set the alarm threshold level at 30 percent FSH for HP compressor drum P/N
6A7705, 6A8316, 6B1385R and 6B1386. For all other HP compressor drum P/Ns
set the alarm threshold level at 55 percent FSH (Refer to Figure 25).
AH.Install the manipulator and ultrasonic probe (IAE2R19859 or IAE2R19880) into
the engine
CAUTION: DUE TO THE SIMILARITY BETWEEN THE INNER AND OUTER DIAMETER INSPECTION
TOOLS,R CARE MUST BE TAKEN TO ENSURE THE CORRECT PROBE AND WORKING
STANDARD HAVE BEEN SELECTED FOR THE RELEVANT INSPECTION.
(1) Position the distilled or de-ionised water container at a suitable
position on the engine. Make sure the container is supported above the
probe position. Attach the end of the water supply tube to the connector
on the rear of the manipulator. Open the valve on the water container and
make sure that water flows from the probe face with no sign of air
bubbles. When water flows from the probe, close the valve on the water
container.
V2500−ENG−72−0615
Page 43
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 46

(2) Before installing the manipulator/probe into the engine, make sure all
parts are secure. Make sure the attachment bolt for the ultrasonic probe
is secure, the spring is not bent and the cable is not damaged.
NOTE: 1. Two standards of bleed air slots may be found on engines. The
current modification standard has longer elongated slots (Refer
to Figure 26) however a number of engines have an earlier
modification standard with smaller square slots (Refer to
Figure 27). The gaps between the stator platforms are
identical; however, the larger slot allows more freedom to
allow the probe to fit easily into the gap between the stators.
Installing the probe into the smaller slot is more difficult
due to the smaller space available; in this case, the probe
face initially contacts the corner of the lower stator platform
(Refer to Figure 27).
2. To install the probe to the smaller slot, first angle the head
of the probe upwards a few degrees by gently rotating the probe
head on the attachment bolt. Holding the manipulator as low as
possible during entry, will allow the probe to slide upwards as
it enters the slot avoiding the corner of the stator. When
installed, the manipulator assembly should be pushed on to the
liner to ensure contact and to center the probe.
3. During withdrawal, the probe will contact the inner surface of
the stator platform preventing withdrawal. By applying gentle
pressure to the manipulator, and again adjusting the probe head
angle, whilst the probe is still in the engine, the probe will
be able to be withdrawn. Excessive force must not be used
during removal.
CAUTION: DO NOT APPLY FORCE TO THE MANIPULATOR OR DAMAGE MAY OCCUR TO THE
PROBE AND ENGINE.
(3) Use CoMat 10-058 to lightlyR oil the threads of the mounting bolts. Offer
the probe to the forward side of the HP compressor bleed valve port (Refer
to Figure 21) through the bleed slot adjacent to the flat-headed D bolt.
Carefully allow the probe to enter the HP compressor casing until it
contacts the ceramic liner. Carefully slide the manipulator mounting plate
up to the bleed valve flange. Manually screw the bolts into the bolt holes
ensuring the mounting plate remains in contact with the bleed valve flange
and the probe manipulator assembly is free to move. Tighten the bolts
alternately whilst checking the probe manipulator assembly remains free to
move.
(4) When correctly installed, the probe manipulator assembly should be able to
slide freely in the mounting block and be able to make contact with the
liner. Figure 22 shows the manipulator assembly installed to the engine.
V2500−ENG−72−0615
Page 44
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 47

AI.Inspect the disc
(1) Open the water couplant valve fully and turn the HP compressor in a
clockwise direction until the probe is positioned between the two locking
nuts of the stage 7R locking blades (Refer to Figure 29). Apply light
inward pressure and make sure the probe is coupled with the liner by
watching the flaw detector time base response. Withdraw the probe
manipulator assembly slightly and watch the change in time base display
when the probe is not coupled. Return the probe to the coupled position.
NOTE: Water levels in the container must be monitored through the
inspection. If the container is found to be empty during the
inspection, the container must be refilled and the inspection
repeated.
(2) When the probe is coupled, zero the turning tool counter number datum and
begin the inspection. If the HP compressor is being turned manually, use a
borescope to locate a datum feature that can be used to confirm a complete
rotation of the drum.
NOTE: 1. The flaw detector time base signals must be constantly
monitored during the inspection, as no back-wall or geometry
signals appear on the time base and loss of coupling could
occur at any time.
2. During inspection monitor the distilled or de-ionised water
level, replenish as necessary.
(3) The flaw detector should be monitored for signals that move along the
timebase in the gated area (30 percent or 55 percent). Any ultrasonic
responses that break the alarm gate, will cause the engine to be rejected
(Refer to Figure 25).
(4) Cracks that have developed on the inner surface of the disc will appear
(maximize)R within the gate on the time base at half skip distance (Refer
to Figure 25).
(5) Inspect the full circumference of the disc, if the ceramic liner allows.R
(6) If turning tool is used, record the amplitude and timebase position
indications over the threshold. Record the degree position on the
accomplishment proforma.
R
R
R
V2500−ENG−72−0615
Page 45
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 48

CAUTION: LIFT THE PROBE CLEAR OF THE CERAMIC LINER BEFORE YOU REVERSE THE
DIRECTION OF THE HP COMPRESSOR, TO PREVENT DAMAGE TO THE PROBE.
(7) If the probe 'picks up' or 'chatters' when the HP compressor is rotated in
a clockwise direction, Rotate the HP compressor in a counterclockwise
direction and repeat the inspection.
NOTE: 1. It is expected that there may be differences in signals when
the HP compressor is rotated in different directions. This is
because the direction of rotation changes the way the probe
sits on the liner. Additionally, the water comes in from one
direction only, which affects the function of the couplant. It
is recommended not to change the direction of rotation during
an inspection pass.
2. Missing stage 7 liner directly underneath the path of the probe
may cause damage to the probe, requiring the probe to be lifted
off the liner during inspection. If liner loss under the path
of the probe is found, this must be noted on the Accomplishment
Proforma, as well as the percentage of the circumference which
was not ultrasonically inspected. If damage is detected on the
pre-inspection assessment, the borescope should be inserted
during the ultrasonic inspection to monitor the liner during
rotation.
3. The borescope inspection for liner material loss is required to
ensure clearance of the rotor path for the ultrasonic probe.
This is recorded for information only, and does not need to be
stamped off as part of the formal accomplishment records. the
results of the borescope inspection for liner cracks or
staining determine further engine serviceability.
AJ.Remove the probe manipulator assembly from the engine
(1) On completion of the inspection, close the water valve and remove the
water supply tube from the manipulator. Undo the bolts and carefully ease
the manipulator from the bleed valve port.
CAUTION: DO NOT USE EXCESSIVE FORCE TO REMOVE THE PROBE MANIPULATOR ASSEMBLY
FROM THE ENGINE.
(2) Close the lock plate and remove the flange mount bolts. Carefully remove
the probe manipulator assembly from the engine.
(3) Make sure all parts of the probe manipulator assembly are present and
undamaged.
V2500−ENG−72−0615
Page 46
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 49

AK.Make a check of the ultrasonic equipment calibration
(1) Make a check of the calibration of the ultrasonic equipment after the
inspection is completed. Carry out the check in accordance with paragraph
3.AG. (1) to (4). If the calibration is under sensitive by more than 3dB,
re-calibrate the ultrasonic equipment and carry out an inspection of the
disc again.
(2) If the calibration is satisfactory, disconnect the turning tool and remove
it from the engine
(a) Remove the turning tool from the accessory gearbox in accordance with
the manufacturer's operating instructions (Refer to the Aircraft
Maintenance Manual,R TASK 72-00-00-080-010).
OR
(b) Remove the hand turning tool from the accessory gearbox (Refer to the
Aircraft Maintenance Manual,R TASK 72-00-00-860-010).
NOTE: 1. All equipment including the probe manipulator assembly
water supply tube and the water bottle should be thoroughly
drained and dried before storing, to prevent corrosion.
2. Due to the similarity between the inner and outer diameter
inspection kits, care must be taken to ensure the correct
probes and working standards are replaced in the correct
storage cases. Part numbers of the individual tools are
marked on the case labels and on the tools.
AL.Accept and reject criteria
(1) For HP compressor drum P/N 6A7705, 6A8316, 6B1385R and 6B1386:
(a) Any ultrasonic response in the gated area above or at the amplitude of
30 percent FSH - reject the engine.
R
R
(b) Any ultrasonic response in the gated area below the amplitude of 30
percent FSH - accept.
R
R
(2) For all other HP compressor drum P/Ns:
(a) Any ultrasonic response in the gated area above or at the amplitude of
55 percent FSH - reject the engine.
R
R
(b) Any ultrasonic response in the gated area below the amplitude of 55
percent FSH - accept.
R
R
V2500−ENG−72−0615
Page 47
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 50

AM.Install the HP stage 7 bleed valve air duct on the left side of the engine.
(1) Install the HP stage 7 bleed valve air duct together with the HP
compressor stage 7 bleed valve
R
R
(a) Lubricate all threads and abutment faces of nuts and bolts with CoMat
10-077 (approved engine oil) and CoMat 10-094 (anti seize compound).R
(b) Hold the HP stage 7 bleed valve air duct (75-00-49, 01-250) in the
correct position on the HP compressor case and align the bolt holes.
(c) Install the 12 bolts (75-00-49, 01-252), with the bracket (75-00-49,
01-235) and the bracket (75-00-49, 01-240).
(d) Torque the twelve bolts (75-00-49, 01-252) to 85 to 105 lbf in. (10 to
12 Nm).
(e) Install the 'v' clamp (36-11-41, 01-100).
(f) Torque the coupling nut on 'v' clamp (36-11-14, 01-100) to 75 to 85
lbf in. (8,5 to 9,6 Nm). Use a soft faced hammer and tap around the
outside of the coupling.
(g) Torque the coupling nut again. Use the above procedure three more
times.
AN.Make sure that the work area is clean and clear of tools, equipment and other
unwanted materials.
AO.Close the access to the HP compressor stage 7 bleed valve aperture that is
installed on the left side of the engine
(1) Close the fan cowl doors (Refer to the Aircraft Maintenance Manual,
Chapter 71-13-00).
(2) Close both halves of the thrust reverser (Refer to the Aircraft
Maintenance Manual, Chapter 78-32-00).
(3) Activate the thrust reverser Hydraulic Control Unit (HCU) (Refer to the
Aircraft Maintenance Manual, Chapter 78-30-00).
(4) Do anR idle leak check (Refer to the Aircraft Maintenance Manual, Chapter
71-00-00).
AP.Recording Instructions
(1) A record of accomplishment is required. Complete a separate Accomplishment
Proforma for outer and inner diameter.
V2500−ENG−72−0615
Page 48
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 51

(2) Record the incorporation of Non-Modification Service Bulletin
V2500-ENG-72-0615R in the applicable engine records.
(3) If the heatshield rework was performed make a note of this in the engine
records.
V2500−ENG−72−0615
Page 49
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 52

INSTRUCTION II - APPLICABLE FOR ENGINES "AT OVERHAUL/SHOP VISIT"
Part A - For V2500-A1 Engines
AQ.General
Use the new inspection kit IAE2R19882 or the old inspection kit IAE2R19864 to
carry out an ultrasonic inspection on the outer diameter of the HP compressor
stage 8 disc adjacent to the stage 7-8 EB weld land.
(1) Obey all the WARNINGS and CAUTIONS in the procedures that are referred to.
(2) Consumable Materials
(a) Refer to the table that follows:
MATERIAL NO. DESIGNATION
01-201 Distilled or De-ionised water
10-058 Penetrating Oil
For the details of the consumable materials given in the table above,
refer to the Overhaul Processes and Consumables Index.
(3) Tools and Equipment
(a) Refer to the table that follows:
ITEM DESCRIPTION TOOL NUMBER
(a) Inspection kit contains the outer diameter
location inspection kit of item (b) in this
table and the inner diameter location
inspection kit of item (b) of the table in
section 3.BA.(3)(a) of this Non-Modification
Service Bulletin)
OR
IAE2R19882
(b) Outer diameter location inspection kit
*(contains items (c) to (g)
IAE2R19864
(c) Ultrasonic probe manipulator assembly IAE2R19865
(d) Couplant feed manipulator IAE2R19867
(e) Couplant feed system IAE2R19807
(f) Working standard IAE2R19854
(g) MCX/BNC lead IAE2R19755
(h) Ultrasonic flaw detector, frequency
selectable in the 5.0 MHz range with
audible/visual electronic alarm gate
Not supplied
(i) 4 to 6 mm flexible borescope kit with image
capture capability
Not supplied
(j) Turning tool (if applicable) Not supplied
(k) Bolts (2 off) AS48516 or
4W0170
R
R
not supplied
V2500−ENG−72−0615
Page 50
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 53

(l) Washers to fit item (k) Not supplied
NOTE: 1. The lead for the ultrasonic probe is supplied with a BNC
connector installed. An adaptor may be required if
alternative equipment is used.
2. The compressor can be turned manually, but an electronic
turning tool is recommended to perform the inspection.
3. Care should be taken to keep the two working standards
IAE2R19854 and IAE2R19860 separate.
AR.Get access to the HP compressor stage 7 bleed valve aperture that is installed
on the left side of the engine.
AS.Remove the stage 7 air off-take duct from the left side of the engine (Refer to
the Engine Manual, Chapter 72-00-40 and to Figure 1 of this Service Bulletin).
AT.Install the turning tool and the borescope
(1) Install the turning tool to the accessory gearbox in accordance with the
manufacturer's operating instructions. Install the V2500 A1 software
module on the control unit, set the HP compressor rotation speed to the
slowest (10 minutes per revolution). Set the HP compressor stage to HPC8
and engage continuous rotation mode.
OR
(2) Install the hand turning tool to the accessory gearbox.
V2500−ENG−72−0615
Page 51
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 54

CAUTION: IF MATERIAL IS MISSING FROM THE CERAMIC LINER, LIFT THE PROBE OFF THE
LINER DURING INSPECTION TO PREVENT DAMAGE TO THE PROBE.
(3) Access the liner through the HP compressor Stage 7C bleed valve manifold
aperture on the left side of the engine (Refer to Figures 2 and 3). Insert
the flexible borescope and position between the stage seven stator vanes
to look down on the surface of the stage seven liner (Refer to Figure 3).
Make sure the borescope is clear of the stage 8 rotor blades and use the
turning tool to rotate the compressor one full revolution. Visually
examine the ceramic liner for any missing material, which could damage the
ultrasonic probe during the inspection rotationR and any staining or
indications of axial cracking (Refer to Figure 4).R A wear line on the
liner may be visible at the trailing edge of the stators, this is the
approximate seating position of the ultrasonic probe and particular
attention should be paid to this area around the circumference of the disc
(Refer to Figure 17).
NOTE: If staining or indications of axial cracking is found, contact the
local IAE office for further guidance before continuing.
R
R
NOTE: Missing stage 7-8R liner material directly underneath the path of
the probe may cause damage to the probe, requiring the probe to be
lifted off the liner during inspection. If liner loss under the
path of the probe is found, this must be noted on the
Accomplishment Proforma, as well as the percentage of the
circumference which was not ultrasonically inspected. If damage is
detected on the pre-inspection assessment, the borescope should be
inserted during the ultrasonic inspection to monitor the liner
during rotation.
NOTE: The borescope inspection for liner material loss is required to
ensure clearance of the rotor path for the ultrasonic probe. This
is recorded for information only, and does not need to be stamped
off as part of the formal accomplishment records. the results of
the borescope inspection for liner cracks or staining determine
further engine serviceability.
AU.Calibrate the ultrasonic equipment
Range 28 mm (nominal)
Material velocity 3100 m/s
Delay 0.00 micro seconds
Frequency Selectable in the 5.0 MHz
range
Damping 50 Ohms
Rectify Full
Pulser Single crystal
V2500−ENG−72−0615
Page 52
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 55

Gate position 4.0 - 6.0 timebase position
NOTE: 1. The nominal settings above are for a USN 52 or equivalent flaw
detector to achieve approximateR signal timebase positions.
Alternative instruments may require different settings.
2. For calibration purposes the couplant feed manipulator should
be detached as described in AV. (4) thru (7) in REVERSE order.
3. Care should be taken to keep the two working standards
IAE2R19854 and IAE2R19860 separate.
(1) Attach the lead to the manipulator/flaw detector, apply the distilled or
de-ionised water and position the probe (IAE2R19865) on to the working
standard (IAE2R19854) (Refer to Figure 5).
(2) Position the probe on the working standard with the flat face on the
working standard and the probe mounting screw facing the working standard.
Make sure attachment bolt for the ultrasonic probe is secure, the spring
is not bent and the cable is not damaged. The 0.04 in. long by 0.02 in.
deep (1,0 mm l by 0,5 mm) EDM target is located in the center of the base
of the working standard (Refer to Figure 5).
NOTE: 1. If calibration is carried out with the working standard in
contact with a secondary surface, excessive couplant on the
working surface and EDM target surface, may allow transfer of
sound into the secondary surface. This can result in a weak
signal and incorrect calibration.
2. During calibration make sure that the probe is fully flat down
on the two contact faces of the working standard. Failure to do
so can result in incorrect calibration.
3. Make sure that the probe is positioned correctly on the working
standard and the reflected signal is not from the corner of the
block.
(3) With the probe positioned on the working standard (Refer to figure 5),
identify the response from the EDM target at half skip distance. Maximize
the signal response to achieve 70 percent Full Screen Height (FSH) and
adjust the range control to position the EDM target signal at five on the
timebase (Refer to Figure 6).
(4) Position the gate between the 4.0 and 6.0 divisions on the timebase and
set the alarm threshold level at 40 percent FSH.
V2500−ENG−72−0615
Page 53
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 56

AV.Install the manipulator and ultrasonic probe (IAE2R19865) into the engine
CAUTION: DUE TO THE SIMILARITY BETWEEN THE INNER AND OUTER DIAMETER INSPECTION
TOOLS,R CARE MUST BE TAKEN TO ENSURE THE CORRECT PROBE AND WORKING
STANDARD HAVE BEEN SELECTED FOR THE RELEVANT INSPECTION.
(1) Position the distilled or de-ionised water container at a suitable
position on the engine. Make sure the container is supported above the
probe position. Attach the end of the water supply tube to the connector
on the rear of the manipulator. Open the valve on the water container and
make sure that water flows from the probe face with no sign of air
bubbles. When water flows from the probe, close the valve on the water
container.
(2) Before installing the manipulator/probe into the engine, make sure all
parts are secure. Make sure the attachment bolt for the ultrasonic probe
is secure, the spring is not bent and the cable is not damaged. Make sure
the water tube is removed from the manipulator assembly to allow the probe
to be inserted into the engine.
R
R
R
NOTE: Figure 7 shows the component parts of the probe assembly. Figure 8
shows the fully assembled probe and couplant feed tube correctly
assembled.
CAUTION: DO NOT APPLY FORCE TO THE MANIPULATOR OR DAMAGE MAY OCCUR TO THE
PROBE AND ENGINE.
(3) Use CoMat 10-058 to lightly oil the threads of the mounting bolts.
Position the probe manipulator arm to the forward side of the HP
compressor bleed valve port with the manipulator lock plate closed. Make
sure that the probe arm is installed to the correct bleed valve aperture
(Refer to Figure 9). Install the probe into the HP compressor case until
it contacts the ceramic liner. Slide the manipulator mount plate up to the
flange of the bleed valve. Hold the mount plate in contact with the flange
of the bleed valve and install the bolts by hand. Make sure the probe
manipulator assembly is free to move and tighten the bolts.
NOTE: When correctly installed, the probe manipulator assembly should be
able to slide freely in the mount plate and be able to make contact
with the liner.
(4) Open the manipulator lock plate and carefully install the couplant
manipulator into the same aperture and above the probe manipulator.
(5) Make sure that the probe and couplant arms are contacting the ceramic
liner and tighten the spring clamp.
(6) Retract the tension spring lock plate until it can be installed over the
couplant arm mount boss (Refer to Figure 10).
V2500−ENG−72−0615
Page 54
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 57

(7) Make sure the probe and couplant arms are exactly aligned and tighten the
spring clamp.
(8) Connect the couplant feed system to the couplant feed manipulator
NOTE: Figure 11 shows the ultrasonic probe manipulator assembly correctly
installed on the engine.
Make sure that the couplant feed manipulator is not mounted forward
of the probe, this will prevent reliable contact with the liner.
When the couplant feed tube and probe manipulator are correctly
aligned, the assembly is correctly installed.
AW.Inspect the disc
(1) Open the water couplant valve to fully open and turn the HP compressor in
a clockwise direction until the probe is positioned between the two
locking nuts of the stage 7R locking blades (Refer to Figure 29). Apply
light inward pressure and make sure the probe is coupled with the liner by
watching the flaw detector timebase response. Withdraw the probe
manipulator assembly slightly and watch the change in timebase display
when the probe is not coupled. Return the probe to the coupled position.
NOTE: Water levels in the container must be monitored through the
inspection. If the container is found to be empty during the
inspection, the container must be refilled and the inspection
repeated.
R
R
R
R
(2) When the probe is coupled, zero the turning tool counter number datum and
begin the inspection. If the HP compressor is being turned manually, use a
borescope to locate a datum feature that can be used to confirm a complete
rotation of the drum.
NOTE: 1. The flaw detector timebase signals must be constantly monitored
during the inspection, as no back-wall or geometry signals
appear on the timebase and loss of coupling could occur at any
time.
2. During inspection monitor the distilled or de-ionised water
level, replenish as necessary.
(3) The flaw detector should be monitored for signals that move along the
timebase in the gated area. Any ultrasonic responses that break the alarm
gate, will cause the engine to be rejected (Refer to Figure 12).R
(4) Cracks that have developed on the inner surface of the disc will appear
(maximize)R within the gate on the timebase at half skip distance (Refer to
Figure 12).R
(5) Inspect the full circumference of the disc, if the ceramic liner allows.R
V2500−ENG−72−0615
Page 55
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 58

(6) If turning tool is used, record the amplitude and timebase position
indications over the threshold. Record the degree position on the
accomplishment proforma.
R
R
R
CAUTION: LIFT THE PROBE CLEAR OF THE CERAMIC LINER BEFORE YOU REVERSE THE
DIRECTION OF THE HP COMPRESSOR, TO PREVENT DAMAGE TO THE PROBE.
(7) If the probe 'picks up' or 'chatters' when the HP compressor is rotated in
a clockwise direction, Rotate the HP compressor in a counterclockwise
direction and repeat the inspection.
NOTE: 1. It is expected that there may be differences in signals when
the HP compressor is rotated in different directions. This is
because the direction of rotation changes the way the probe
sits on the liner. Additionally, the water comes in from one
direction only, which affects the function of the couplant, It
is recommended not to change the direction of rotation during
an inspection pass.
2. Missing stage 7 liner directly underneath the path of the probe
may cause damage to the probe, requiring the probe to be lifted
off the liner during inspection. If liner loss under the path
of the probe is found, this must be noted on the Accomplishment
Proforma, as well as the percentage of the circumference which
was not ultrasonically inspected. If damage is detected on the
pre-inspection assessment, the borescope should be inserted
during the ultrasonic inspection to monitor the liner during
rotation.
3. The borescope inspection for liner material loss is required to
ensure clearance of the rotor path for the ultrasonic probe.
This is recorded for information only, and does not need to be
stamped off as part of the formal accomplishment records. the
results of the borescope inspection for liner cracks or
staining determine further engine serviceability.
AX.Remove the probe manipulator assembly from the engine
(1) After the inspection is complete, close the water valve and remove the
water supply tube from the couplant manipulator assembly. Slacken the
manipulator lock plate screw, remove the couplant manipulator assembly,
remove the couplant manipulator assembly from the bleed valve aperture.
CAUTION: DO NOT USE EXCESSIVE FORCE TO REMOVE THE PROBE MANIPULATOR ASSEMBLY
FROM THE ENGINE.
(2) Close the lock plate and remove the flange mount bolts. Carefully remove
the probe manipulator assembly from the engine.
(3) Make sure all parts of the probe manipulator assembly are present and
undamaged.
V2500−ENG−72−0615
Page 56
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 59

AY.Make a check of the ultrasonic equipment calibration
(1) Make a check of the calibration of the ultrasonic equipment after the
inspection is completed. Carry out the check in accordance with paragraph
3.AU. (1) to (4). If the calibration is under sensitive by more than 3dB,
re-calibrate the ultrasonic equipment and carry out an inspection of the
disc again.
AZ.Accept and reject criteria
(1) Any ultrasonic response in the gated area above or at the amplitude of 40
percent FSH - reject the engine.
R
R
(2) Any ultrasonic response in the gated area below the amplitude of 40
percent FSH - accept.
R
R
BA.General
Use the new inspection kit IAE2R19882 or the old inspection kit IAE2R19869 to
carry out an ultrasonic inspection on the inner diameter of the HP compressor
stage 8 disc adjacent to the 7-8 EB weld land.
(1) Obey all the WARNINGS and CAUTIONS in the procedures that are referred to.
(2) Consumable Materials
(a) Refer to the table that follows:
MATERIAL NO. DESIGNATION
01-201 Distilled or De-ionised water
10-058 Penetrating Oil
For the details of the consumable materials given in the table above,
refer to the Overhaul Processes and Consumables Index.
(3) Tools and Equipment
(a) Refer to the table that follows:
ITEM DESCRIPTION TOOL NUMBER
(a) Inspection kit contains the inner diameter
location inspection kit of item (b) in this
table and the outer diameter location
inspection kit of item (b) of the table in
section 3.AQ.(3)(a) of this Non-Modification
Service Bulletin.
OR
IAE2R19882
(b) Inspection kit
*(contains items (c) to (g)
IAE2R19869
(c) Ultrasonic probe manipulator assembly IAE2R19870
(d) Couplant feed manipulator IAE2R19871
V2500−ENG−72−0615
Page 57
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

### Page 60

(e) Couplant feed system IAE2R19807
(f) Working standard IAE2R19860
(g) MCX/BNC lead IAE2R19755
(h) Ultrasonic flaw detector, frequency
selectable in the 5.0 MHz range with
audible/visual electronic alarm gate
Not supplied
(i) 4 to 6 mm flexible borescope kit with image
capture capability
Not supplied
(j) Turning tool (if applicable) Not supplied
(k) Bolts (2 off) AS48516 or
4W0170
R
R
not supplied
(l) Washers to fit item (k) Not supplied
NOTE: 1. The lead for the ultrasonic probe is supplied with a BNC
connector installed. An adaptor may be required if
alternative equipment is used.
2. The compressor can be turned manually, but an electronic
turning tool is recommended to perform the inspection.
3. Care should be taken to keep the two working standards
IAE2R19854 and IAE2R19860 separate.
BB.Calibrate the ultrasonic equipment
Range 59 mm (nominal)
Material velocity 3100 m/s
Delay 0.00 micro seconds
Frequency Selectable in the 5.0 MHz
range
Damping 50 Ohms
Rectify Full wave
Pulser Single crystal
Gate position 3.0 - 8.0 timebase position
NOTE: 1. The nominal settings above are for a USN 52 or equivalent flaw
detector to achieve signal timebase positions. Alternative
instruments may require different settings.
2. For calibration purposes the couplant feed manipulator should
be detached as described in BC.(4) thru (7) in REVERSE order.
3. Care should be taken to keep the two working standards
IAE2R19854 and IAE2R19860 separate.
(1) Attach the lead to the manipulator/flaw detector, apply the distilled or
de-ionised water and position the probe (IAE2R19870) on to the working
standard (IAE2R19860) (Refer to Figure 5).
V2500−ENG−72−0615
Page 58
Jul.19/10
Sep.20/11 Revision 3
IAE PROPRIETARY INFORMATION
© IAE International Aero Engines AG. All rights reserved.

The text continues at https://openairdocs.org/service-documents/iae/v2500-eng-72-0615/file/0a5400a2036b.md?from=61

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.