KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
 
 Transmittal Sheet 
Summary 
This service bulletin provides a bench test procedure for Continuous Fire Detector (CFD)  
sensing elements to verify proper operation. Failed units will be replaced by Kidde Aerospace 
and Defense. 
NOTE: This Service Bulletin is classified under Chapter 26 due to the initial classification of the          
CFD product line.  Airbus classifies the Overheat Detection System (OHDS) as Sensing Elements 
under Chapter 36.  CFD's and OHDS Sensing Elements reference the same product.    
 
Service Bulletin Revision History 
 
REVISION DATE OF RELEASE 
Initial Release 
(IR)   January 13, 2022 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Subject to the EAR, ECCN 9E991 
. 
 
The data in this document were developed only to maintain systems and/or parts manufactured by or for Collins Aerospace 
or approved by Collins Aerospace. The data may not be applicable to any other systems and/or parts, regardless of their 
apparent similarity to systems and/or parts manufactured by or for Collins Aerospace or approved by Collins Aerospace. 
Do not rely in any way on data in this document to maintain or otherwise support systems and/or parts that wer e not 
manufactured by or for Collins Aerospace or approved by Collins Aerospace without evidence that the Federal Aviation 
Administration or other regulatory agency has determined that the data in this document is valid for such use.  
 
Collins Aerospace assumes no liability whatsoever, whether contractual, warranty, tort or otherwise, for unauthorized 
alteration or alterations not performed in accordance with Collins Aerospace approved procedures.

### Page 2

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 1 of 30 
 
1. PLANNING INFORMATION 
A. Effectivity 
This Service Bulletin (SB) is applicable for CFD (sensing elements) Units. 
 
PART NUMBER APPLICABLE TO 
DATE CODE 
PART NUMBER APPLICABLE TO 
DATE CODE 
PART NUMBER APPLICABLE TO 
DATE CODE 
04-195006-001 Before A2105 04-90014-9186A Before A2105 04-90014-9268A Before A2105 
04-195007-001 Before A2105 04-90014-9187A Before A2105 04-90014-9269A Before A2105 
04-90014-9088A Before A2105 04-90014-9190A Before A2105 04-90014-9271A Before A2105 
04-90014-9098A Before A2105 04-90014-9195A Before A2105 04-90014-9272A Before A2105 
04-90014-9099A Before A2105 04-90014-9196A Before A2105 04-90014-9274A Before A2105 
04-90014-9102A Before A2105 04-90014-9197A Before A2105 04-90014-9275A Before A2105 
04-90014-9113A Before A2105 04-90014-9198A Before A2105 04-90014-9277A Before A2105 
04-90014-9115A Before A2105 04-90014-9200A Before A2105 04-90014-9280A Before A2105 
04-90014-9117A Before A2105 04-90014-9202A Before A2105 04-90014-9281A Before A2105 
04-90014-9119A Before A2105 04-90014-9203A Before A2105 04-90014-9283A Before A2105 
04-90014-9120A Before A2105 04-90014-9204A Before A2105 04-90014-9284A Before A2105 
04-90014-9121A Before A2105 04-90014-9208A Before A2105 04-90014-9286A Before A2105 
04-90014-9122A Before A2105 04-90014-9209A Before A2105 04-90014-9287A Before A2105 
04-90014-9126A Before A2105 04-90014-9211A Before A2105 04-90014-9288A Before A2105 
04-90014-9130A Before A2105 04-90014-9212A Before A2105 04-90014-9289A Before A2105 
04-90014-9134A Before A2105 04-90014-9213A Before A2105 04-90014-9295A Before A2105 
04-90014-9136A Before A2105 04-90014-9215A Before A2105 04-90014-9305A Before A2105 
04-90014-9137A Before A2105 04-90014-9216A Before A2105 04-90014-9310A Before A2105 
04-90014-9140A Before A2105 04-90014-9217A Before A2105 04-90014-9312A Before A2105 
04-90014-9142A Before A2105 04-90014-9218A Before A2105 04-90014-9314A Before A2105 
04-90014-9143A Before A2105 04-90014-9228A Before A2105 04-90014-9318A Before A2105 
04-90014-9145A Before A2105 04-90014-9234A Before A2105 04-90014-9320A Before A2105 
04-90014-9147A Before A2105 04-90014-9236A Before A2105 04-90014-9321A Before A2105 
04-90014-9148A Before A2105 04-90014-9237A Before A2105 04-90014-9323A Before A2105 
04-90014-9149A Before A2105 04-90014-9238A Before A2105 04-90014-9324A Before A2105 
04-90014-9150A Before A2105 04-90014-9239A Before A2105 04-90014-9325A Before A2105 
04-90014-9151A Before A2105 04-90014-9240A Before A2105 04-90014-9328A Before A2105 
04-90014-9152A Before A2105 04-90014-9241A Before A2105 04-90014-9332A Before A2105 
04-90014-9155A Before A2105 04-90014-9242A Before A2105 04-90014-9339A Before A2105 
04-90014-9158A Before A2105 04-90014-9243A Before A2105 04-90014-9348A Before A2105 
04-90014-9165A Before A2105 04-90014-9244A Before A2105 04-90014-9351A Before A2105 
04-90014-9166A Before A2105 04-90014-9245A Before A2105 04-90014-9361A Before A2105 
04-90014-9167A Before A2105 04-90014-9246A Before A2105 04-90014-9363A Before A2105 
04-90014-9168A Before A2105 04-90014-9248A Before A2105 04-90016-901 Before A2105 
04-90014-9169A Before A2105 04-90014-9251A Before A2105 04-90016-902 Before A2105 
04-90014-9170A Before A2105 04-90014-9252A Before A2105 1002008-051C Before A2105 
04-90014-9171A Before A2105 04-90014-9253A Before A2105 1004008-046D Before A2105 
04-90014-9172A Before A2105 04-90014-9254A Before A2105 1005008-046D Before A2105 
04-90014-9173A Before A2105 04-90014-9256A Before A2105 1070001-217A00 Before A2105 
04-90014-9175A Before A2105 04-90014-9257A Before A2105 1070001-221A00 Before A2105 
04-90014-9176A Before A2105 04-90014-9258A Before A2105 1072001-041A00 Before A2105 
04-90014-9180A Before A2105 04-90014-9259A Before A2105 1072001-041M00 Before A2105 
04-90014-9181A Before A2105 04-90014-9263A Before A2105 1072001-044A00 Before A2105 
04-90014-9183A Before A2105 04-90014-9264A Before A2105 1072001-044M00 Before A2105 
04-90014-9184A Before A2105 04-90014-9267A Before A2105 1072001-046M00 Before A2105

### Page 3

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 2 of 30 
 
PART NUMBER APPLICABLE TO 
DATE CODE 
PART NUMBER APPLICABLE TO 
DATE CODE 
PART NUMBER APPLICABLE TO 
DATE CODE 
1072001-055A00 Before A2105 1072001-173A00 Before A2105 1072001-245A51 Before A2105 
1072001-059A00 Before A2105 1072001-173A51 Before A2105 1072001-247A00 Before A2105 
1072001-072A00 Before A2105 1072001-185A00 Before A2105 1072001-247A51 Before A2105 
1072001-075A51 Before A2105 1072001-186A00 Before A2105 1072001-248A00 Before A2105 
1072001-078A00 Before A2105 1072001-186A51 Before A2105 1072001-248A51 Before A2105 
1072001-080A00 Before A2105 1072001-188A00 Before A2105 1072001-250A95 Before A2105 
1072001-080A51 Before A2105 1072001-191A00 Before A2105 1072001-251A00 Before A2105 
1072001-086A00 Before A2105 1072001-197A00 Before A2105 1072001-251A51 Before A2105 
1072001-086A51 Before A2105 1072001-197A51 Before A2105 1072001-255A00 Before A2105 
1072001-087A00 Before A2105 1072001-200A00 Before A2105 1072001-255A51 Before A2105 
1072001-087A51 Before A2105 1072001-200A51 Before A2105 1072001-256A00 Before A2105 
1072001-090A00 Before A2105 1072001-201A00 Before A2105 1072001-256A51 Before A2105 
1072001-090A51 Before A2105 1072001-205A00 Before A2105 1072001-260A95 Before A2105 
1072001-091A00 Before A2105 1072001-205A51 Before A2105 1072001-262A00 Before A2105 
1072001-091A51 Before A2105 1072001-206A00 Before A2105 1072001-262A51 Before A2105 
1072001-097A51 Before A2105 1072001-206A51 Before A2105 1072001-263A95 Before A2105 
1072001-105A51 Before A2105 1072001-209A00 Before A2105 1072001-270A00 Before A2105 
1072001-121A00 Before A2105 1072001-209A51 Before A2105 1072001-270A51 Before A2105 
1072001-121A51 Before A2105 1072001-210A00 Before A2105 1072001-277A95 Before A2105 
1072001-126A95 Before A2105 1072001-210A51 Before A2105 1072001-285A00 Before A2105 
1072001-129A00 Before A2105 1072001-212A00 Before A2105 1072001-286A95 Before A2105 
1072001-129A51 Before A2105 1072001-212A51 Before A2105 1072001-287A95 Before A2105 
1072001-131A00 Before A2105 1072001-213A00 Before A2105 1072001-291A00 Before A2105 
1072001-131A51 Before A2105 1072001-213A51 Before A2105 1072001-297A00 Before A2105 
1072001-134A00 Before A2105 1072001-215A00 Before A2105 1072001-297A51 Before A2105 
1072001-134A51 Before A2105 1072001-215A51 Before A2105 1072001-317A95 Before A2105 
1072001-136A95 Before A2105 1072001-217A51 Before A2105 1072001-319A00 Before A2105 
1072001-137A00 Before A2105 1072001-218A00 Before A2105 1072001-319A51 Before A2105 
1072001-140A00 Before A2105 1072001-218A51 Before A2105 1072001-323A00 Before A2105 
1072001-140A51 Before A2105 1072001-219A00 Before A2105 1072001-323A51 Before A2105 
1072001-142A00 Before A2105 1072001-219A51 Before A2105 1072001-328A00 Before A2105 
1072001-149C00 Before A2105 1072001-221A00 Before A2105 1072001-328A51 Before A2105 
1072001-149C01 Before A2105 1072001-221A51 Before A2105 1072001-A049-51 Before A2105 
1072001-149C51 Before A2105 1072001-222A00 Before A2105 1072001-A051-51 Before A2105 
1072001-151A95 Before A2105 1072001-222A51 Before A2105 1072001-A075-51 Before A2105 
1072001-152A00 Before A2105 1072001-223A00 Before A2105 1072001-A098-51 Before A2105 
1072001-152A51 Before A2105 1072001-223A51 Before A2105 1072001-A100-51 Before A2105 
1072001-152C51 Before A2105 1072001-229A00 Before A2105 1072001-A115-51 Before A2105 
1072001-156C01 Before A2105 1072001-229A51 Before A2105 1072001-A120-51 Before A2105 
1072001-158A95 Before A2105 1072001-230A00 Before A2105 1072001-A123-51 Before A2105 
1072001-159A00 Before A2105 1072001-234A00 Before A2105 1072001-A126-51 Before A2105 
1072001-161C00 Before A2105 1072001-234A51 Before A2105 1072001-A136-51 Before A2105 
1072001-161C01 Before A2105 1072001-238A00 Before A2105 1072001-A139-51 Before A2105 
1072001-161C51 Before A2105 1072001-238A51 Before A2105 1072001-A141-51 Before A2105 
1072001-162A00 Before A2105 1072001-240A00 Before A2105 1072001-A151-51 Before A2105 
1072001-162A51 Before A2105 1072001-240A51 Before A2105 1072001-A154-51 Before A2105 
1072001-163A00 Before A2105 1072001-242A95 Before A2105 1072001-A158-51 Before A2105 
1072001-163A51 Before A2105 1072001-243A00 Before A2105 1072001-A162-51 Before A2105 
1072001-166A00 Before A2105 1072001-243A51 Before A2105 1072001-A168-51 Before A2105 
1072001-166A51 Before A2105 1072001-244A95 Before A2105 1072001-A170-51 Before A2105 
1072001-168A95 Before A2105 1072001-245A00 Before A2105 1072001-A171-51 Before A2105

### Page 4

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 3 of 30 
 
PART NUMBER APPLICABLE TO 
DATE CODE 
PART NUMBER APPLICABLE TO 
DATE CODE 
PART NUMBER APPLICABLE TO 
DATE CODE 
1072001-A179-51 Before A2105 35546-2-255 Before A2105 35596-2-310 Before A2105 
1072001-A182-51 Before A2105 35546-2-310 Before A2105 35597-2-255 Before A2105 
1072001-A183-51 Before A2105 35548-2-255 Before A2105 35597-3-255 Before A2105 
1072001-A189-51 Before A2105 35549-2-255 Before A2105 35598-2-255 Before A2105 
1072001-A192-51 Before A2105 35551-2-255 Before A2105 35599-2-255 Before A2105 
1072001-A195-51 Before A2105 35552-2-255 Before A2105 35599-2-310 Before A2105 
1072001-A199-51 Before A2105 35553-2-255 Before A2105 35599-2-310  Before A2105 
1072001-A203-51 Before A2105 35554-2-255 Before A2105 35599-3-255 Before A2105 
1072001-A215-51 Before A2105 35554-4-255 Before A2105 35600-2-255 Before A2105 
1072001-A223-51 Before A2105 35556-2-255 Before A2105 35601-2-255 Before A2105 
1072001-A225-51 Before A2105 35557-2-255 Before A2105 35601-2-310 Before A2105 
1072001-A233-51 Before A2105 35558-2-255 Before A2105 35602-2-255 Before A2105 
1072001-A234-51 Before A2105 35558-2-310 Before A2105 35603-2-255 Before A2105 
1072001-A236-51 Before A2105 35560-2-255 Before A2105 35604-2-255 Before A2105 
1072001-A237-51 Before A2105 35561-2-255 Before A2105 35605-2-255 Before A2105 
1072001-A238-51 Before A2105 35562-2-255 Before A2105 35606-2-255 Before A2105 
1072001-A240-51 Before A2105 35563-2-255 Before A2105 35607-2-255 Before A2105 
1072001-A241-51 Before A2105 35566-2-255 Before A2105 35609-2-255 Before A2105 
1072001-A242-51 Before A2105 35566-2-310 Before A2105 35610-2-255 Before A2105 
1072001-A247-51 Before A2105 35567-2-255 Before A2105 35611-2-255 Before A2105 
1072001-A250-51 Before A2105 35567-3-255 Before A2105 35611-3-255 Before A2105 
1072001-A258-51 Before A2105 35568-2-255 Before A2105 35612-2-255 Before A2105 
1072001-A259-51 Before A2105 35568-4-255 Before A2105 35614-2-255 Before A2105 
1072001-A260-51 Before A2105 35569-2-255 Before A2105 35615-2-255 Before A2105 
1072001-A263-51 Before A2105 35571-2-255 Before A2105 35616-2-255 Before A2105 
1072001-A270-51 Before A2105 35572-2-255 Before A2105 35617-2-255 Before A2105 
1072001-A286-51 Before A2105 35573-2-255 Before A2105 35618-2-255 Before A2105 
1072001-A287-51 Before A2105 35574-2-255 Before A2105 35619-2-255 Before A2105 
1072001-A306-51 Before A2105 35575-2-255 Before A2105 35620-2-255 Before A2105 
1072001-A308-51 Before A2105 35576-2-255 Before A2105 35621-2-255 Before A2105 
1072001-A317-51 Before A2105 35577-2-255 Before A2105 35622-2-255 Before A2105 
1072001-A326-51 Before A2105 35579-2-255 Before A2105 35622-4-310 Before A2105 
1072001-A342-51 Before A2105 35580-2-255 Before A2105 35623-2-255 Before A2105 
1072001-C149-51 Before A2105 35581-2-255 Before A2105 35624-2-255 Before A2105 
1072001-C152-51 Before A2105 35582-2-255 Before A2105 35624-2-310 Before A2105 
1094006-046 Before A2105 35583-2-255 Before A2105 35625-2-255 Before A2105 
1095006-046 Before A2105 35584-2-255 Before A2105 35626-2-255 Before A2105 
35518-48-400 Before A2105 35584-3-255 Before A2105 35627-2-255 Before A2105 
35522-2-255 Before A2105 35586-2-255 Before A2105 35628-2-255 Before A2105 
35523-2-255 Before A2105 35587-2-255 Before A2105 35629-2-255 Before A2105 
35524-2-255 Before A2105 35588-2-255 Before A2105 35630-2-255 Before A2105 
35525-2-255 Before A2105 35589-2-255 Before A2105 35631-2-255 Before A2105 
35526-2-255 Before A2105 35590-2-255 Before A2105 35632-2-255 Before A2105 
35527-2-255 Before A2105 35591-2-255 Before A2105 35633-2-255 Before A2105 
35528-2-255 Before A2105 35592-2-310 Before A2105 35634-2-255 Before A2105 
35532-2-255 Before A2105 35593-2-255 Before A2105 35636-2-255 Before A2105 
35532-2-310  Before A2105 35593-3-255 Before A2105 35636-2-310 Before A2105 
35535-2-255 Before A2105 35594-2-255 Before A2105 35637-2-310 Before A2105 
35535-2-310  Before A2105 35594-2-310 Before A2105 35637-3-255 Before A2105 
35537-2-255 Before A2105 35595-2-255 Before A2105 35638-2-255 Before A2105 
35545-2-310 Before A2105 35596-2-255 Before A2105 35639-2-255 Before A2105

### Page 5

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 4 of 30 
 
PART NUMBER APPLICABLE TO 
DATE CODE 
PART NUMBER APPLICABLE TO 
DATE CODE 
PART NUMBER APPLICABLE TO 
DATE CODE 
35640-2-255 Before A2105 35661-2-310 Before A2105 35774-200-255 Before A2105 
35641-3-255 Before A2105 35663-2-255 Before A2105 35777-200-255 Before A2105 
35642-2-255 Before A2105 35665-2-255 Before A2105 35778-200-255 Before A2105 
35643-2-255 Before A2105 35666-3-310 Before A2105 35780-200-255 Before A2105 
35647-2-255 Before A2105 35667-2-255 Before A2105 35781-200-255 Before A2105 
35650-2-255 Before A2105 35668-2-255 Before A2105 35784-200-255 Before A2105 
35654-2-255 Before A2105 35668-2-310 Before A2105 35795-200-255 Before A2105 
35655-2-255 Before A2105 35670-2-255 Before A2105 35796-200-255 Before A2105 
35658-2-255 Before A2105 35673-2-255 Before A2105 35798-200-255 Before A2105 
35658-2-310 Before A2105 35677-2-255 Before A2105 35808-200-255 Before A2105 
35659-3-310 Before A2105 35680-2-255 Before A2105 35812-200-255 Before A2105 
35660-2-310 Before A2105 35687-2-255 Before A2105   
 
NOTE: Numeric Date Code: AYYWW (YY 2-digit year, WW 2-digit Week) Example A2105 
(Date of Manufacture 5 th week of 2021). 
 
B. Concurrent Requirement 
Not applicable. 
 
C. Reason 
(1) Description of Existing Condition 
(a) CFD sensing elements produced between November 24, 2004 and January 31, 2021 
may not properly detect thermal bleed leak events. This specific failure mode is not 
detectable by Overheat Detection System. 
 
(2) Extent Condition Encountered 
(a) Any CFD sensing elements Part Numbers listed in Section 1.A. may be affected. 
 
(3) Expected Benefits of Modification 
(a) Verification that CFD sensing elements will operate per specification. 
 
(4) Safety Intent of Corrective Action 
(a) Identify inoperable units by testing for functionality. 
(b) Remove inoperable units from the field.

### Page 6

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 5 of 30 
 
(5) Regulatory Action 
(a) To be determined by the governing civil aviation authority. 
 
D. Description 
Shop test CFD sensing elements for proper operation. Failed units will be replaced Free Of 
Charge (FOC) by Kidde Aerospace and Defense. 
 
E. Compliance 
 Optional - Service Bulletin for convenience or option. 
 Desirable - Service Bulletin to introduce improvements. 
X Recommended - Service Bulletin recommended to be accomplished to prevent significant operational disruptions. 
  Mandatory - Service Bulletin must be accomplished. 
 
NOTE: Service Bulletin compliance is Highly Recommended per ATA-2200 definition. 
 
F. Approval 
(1) The approved design of the CFD sensing element part numbers listed in Section 1.A is in 
compliance with the requirements of TSO-C11e. This SB allows you to determine if the 
suspect parts conform to the approved design 
(2) The inspection procedures described in the SB are reviewed and technically accepted by 
Airbus to apply to the Airbus fleet affected.  This SB does not contain any change 
information that revises the equipment definition covered by Airbus approved 
modifications.  
NOTE: This statement is only valid for PN certified by Airbus, refer to paragraph Effectivity.  
G. Manpower 
The total estimated time to accomplish the work in this service bulletin is 0.5 man hours per 
unit. 
TASK ESTIMATED HOURS 
Preparation 0.2 
Installation 0.0 
Testing 0.3 
Total 0.5

### Page 7

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 6 of 30 
 
H. Weight and Balance 
No change. 
 
I. Electrical Load Data 
No change. 
 
J. Software Accomplishment Summary 
None. 
 
K. References 
(1) Abbreviated Component Main tenance Manual (ACMM) fo r 1070001- XXXXXX, 36-22-16 
(2) ACMM for 1072001- XXXXXXX, 36-22-17 
(3) ACMM for 1094006- XXXXXX, 1095006- XXX, 04-90014-XXXX, and 04-90016-XXX, 36-
22-05 
(4) ACMM for 35518-48- XXX and 35XXX-X-XXX, 26-14-12 
 
L. Other Publications Affected 
None. 
 
M. Interchangeab ility or Intermixability of Parts 
N/A 
 
2. MATERIAL INFORMATION 
A. Material - Price and Availability  
Tooling Kit part number 173948 available. 
 
NOTE: Tooling Kit 173948 contains items from tables in Section 2.E. 
 
NOTE: Order if test equipment is not available.

### Page 8

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 7 of 30 
 
NOTE: The current charge for Collins to perform this service bulletin is $794.60 United States 
Dollars (USD) and may be subject to future price adjustments. Pricing is only valid through 
December 31, 2022. 
 
B. Industry Support Information 
(1) The modification materials in this service bulletin may be obtained from: 
Not Applicable 
(2) The tooling kit in this service bulletin may be obtained from: 
Rockwell Collins 
Rental Exchange 
400 Collins Road NE 
Cedar Rapids, IA 52498-0001 
TELEPHONE: 1.800.713.5467 
 
Email: Collinsdispatchprograms@rockwellcollins.com  
 
Include the following: 
Email Subject: CFD NOE Kit 
Provide FOC PO 
Power Requirements: 110V or 220V 
 
NOTE: Please review the commercially available test equipment required in Section 
2.E.(2). Order if test equipment is not available. 
 
(3) Warranty 
For units in and out of warranty, Collins Aerospace will reimburse the cost of this service 
bulletin or perform this service bulletin at no charge for the materials and labor. 
 
NOTE: Warranty claims will be accepted through December 31, 2028. 
 
(4) Instructions for Warranty Claims can be found at: 
https://portal.rockwellcollins.com/web/support-self-service/warranty

### Page 9

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 8 of 30 
 
(5) Operators can also forward claims for labor reimbursement to the e-mail: 
kiddewarranty@collins.com  
 
C. List of Components 
(1) Materials Purchased 
None. 
 
 
(2) Materials Supplied by Customer  
PART NUMBER  KEY WO RD DESCRIPTION QUANTITY SPECIAL I N S TRUCTION/  DISPOSITION 
Commercially Available* Marking Material Customer Preference As Required (AR) Locally Sourced 
* Part is at the customers discretion based on local availability 
D. Subcomponents to be re-identified 
CFD sensing element part numbers listed in Section 1.A  
 
E. Tooling 
(1) Materials Purchased for Testing Procedure 
PART NUMBER  KEY WO RD DESCRIPTION QUANTITY SPECIAL I N S TRUCTION/  DISPOSITION 
Kit 173948 Contains the items below as well as items in the Table from Section 2.E.(2) 
1146006-0254-00  Connecting Cable 100in, Gold, Pin Connector 2 N/A 
1148006-0254-00  Connecting Cable 100in, Gold, Socket Connector 2 N/A 
476232  Shell and  Insert Assy Gold 20 Contact Socket -Capable receiving 0.06  inch (1.52 mm) diameter contact pin 
349457  Contact Pin Gold 20 Gold Plated 0.06  inch (1.52 mm) diameter

### Page 10

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 9 of 30 
 
F. Materials Supplied by Customer for Testing Procedure 
PART NUMBER KEY WO RD DESCRIPTION QUANTITY RANGE TOLERANCE 
BK 879B or 
Equivalent  LCR Meter  Electronic Test Equipment  1 
1 kHz test frequency 
0.6-1.0 Vrms test 
level 
0 VDC 
0-40 k Ω Z impedance  
32-104°F (0- 40 °C) 
operate temp 
±5% 
Not applicable  
±0.02 VDC  
±5% 
Not applicable  
Steinel HG2320E or 
Equivalent Heat Gun Heating Gun  1 32-662°F (0-350 °C) (at nozzle) ±10 °F (±5 °C) 
Steinel 07051 or 
Equivalent Heat Gun Shield Heat Shield 1 N/A N/A 
HH501BJK or Fluke 
289 or Equivalent 
Digital 
Multimeter 
(DMM) or Digital 
Temperature 
Meter (DTM) 
Measures 
 Temperature 1 
Type K input 32-
1100°F (0-594°C) 
 
32-104°F (0-40 °C ) 
operate temp 
±4°F (±2.2°C) or 0.75% 
(whichever is greater) 
 
Not applicable  
 
KMQSS-062U-12 or 
Equivalent  Thermal Couple Measures  Temperature 1 Type K input 32-1100°F (0 -594°C) or greater ±4°F (±2.2°C) or 0.75% (whichever is greater) 
4TM11 or Equivalent Stopwatch  Stopwatch  Time 1 2 minutes (min) 1 second resolution (±5 secs over range) 
 
G. Special Tools 
None. 
 
3. ACCOMPLISHMENT INSTRUCTIONS  
 
NOTE: Some steps in the accomplishment instructions are identified as Required for Compliance 
(RC). If this service bulletin is mandated by an airworthiness directive (AD), the steps identified 
as RC must be done to comply with the AD. Steps not identified with RC are recommended and 
may be deviated from; done as a part of other actions; or done with accepted methods different 
from those given in SB if the RC steps can be done and the airplane returned to a serviceable 
condition.

### Page 11

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 10 of 30 
 
A. General 
(1) RC - Test Environment 
Testing may be performed at a room temperature between 55°F (12.8°C) and 85°F 
(29.4°C), and relative humidity not exceeding 90%. Test area must be free from flammable 
vapors. Work surface used for bench top testing must be made from non-flammable and 
non-conductive materials. 
 
WARNING: Hot air tool can produce up to 1300°F (795°C) of flameless heat at the nozzle. 
Do not direct airstream at clothing, hair, or other body parts. If the hot air is set above 
392°F (200°C), ensure the surroundings are free of fuel vapors and other ignition sources. 
 
WARNING: Do not use near flammable liquids or in an explosive environment (fumes, 
gases, or dust). Remove materials or debris that may become ignited from work area. 
 
WARNING: Always hold tool by plastic enclosure. The metal nozzle requires 
approximately 20 minutes to cool to where it can be touched. Do not touch nozzle or 
accessory tips until cool. 
 
WARNING: Do not store tool until nozzle has cooled to room temperature. Place tool in a 
clear area away from combustible materials while cooling. 
 
WARNING: Use shield materials around the heated area to prevent damage or fire. 
 
CAUTION: Do not cut off airflow by placing nozzle too close to work piece. Keep intake 
vents clean and clear of obstructions. 
 
WARNING: Do not leave tool unattended while running or cooling down. Otherwise risk of 
fire. 
 
CAUTION: Place tool on a level surface when tool is not handheld. Place cord in a position 
that won’t cause tipping.

### Page 12 (OCR)

KIDDE AEROSPACE & DEFENSE
SERVICE BULLETIN
FIRE PROTECTION - AIRBUS CONTINUOUS FIRE DETECTOR (CFD) -
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER
OPERATION
NOTE: Keep a fully charged fire extinguisher nearby.
(2) RC - Sensing Elements Heating Procedure
The following figures show how to use the heat gun. A heat protection shield must be used
and attached to the end of the heat gun outlet. A heat protection shield (Steinel P/N 07051)
is normally supplied in the referenced kit. If not available, the following dimensions can be
followed to produce an acceptable heat protection shield. The heat protection shield shall
be 1.410.2 inch (~3.56 cm 10.5 cm) in width and rolled in a half circle with a radius of
approximately 0.75 inches (1.91 cm) for optimum testing. The end of the half circle shall
be 1.25-1.5 inches (~3.18 to 3.81 cm) away from the heat gun outlet as shown in Figure 1
and Figure 2.
ELEMENT  SEN SING  HEAT GUN OUTLET
HEAT PROTECTION
SHIELD
AIRFLOW
-1.00 to 1.25 INCH-
RADIUS APPROX  (2.54 TO 3.18 cm)
0.75 INCH
(1.91 cm)
- 1.25 to 1.5 INCH
(3.18 TO 3.81 cm)
Figure 1: Heat Protection Shield Side View
OFF-AXIS
THERMOCOUPLE
LOCATION
TC TIP PLACED 0.33 INCH (0.85 cm) FROM CENTERUNE
HEAT GUN OUTLET
1.2 TO 1.6 INCH  _ HEAT PROTECTION  AIRFLOW
(3.06 TO 4.06 cm)
SENSING
ELEMENT  TC TIP ON CENTERLINE OF HEAT FLANGE
CENTER
THERMOCOUPLE
LOCATION  •1.00 to 1.25 INCH
(2.54 TO 3.18 cm)
Figure 2: Heat gun with heat protection shield top down view
January 13/22  CFD-26-3
523-0832622
U.S. Export Classification: EAR 9E991
Page 11 of 30

### Page 13

KIDDE AEROSPACE & DEFENSE
SERVICE BULLETIN
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR(CFD)–
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION
January 13/22 CFD-26-3
523-0832622
U.S. Export Classification: EAR 9E991
         Page 12 of 30
If a curved heat protection shield is not available place a flat heat protection shield (i.e. 
aluminum plate) behind the sensing element being heated and hold the heat gun 1.00 to 
1.25 inch (2.54 to 3.18 cm) from the sensing element as shown in Figure 3.
Figure 3: Heat gun using heat protection shield side view
B. RC - Preparation
(1) Heat Gun Temperature Verification at sensing element position:
NOTE: To ensure that the Heat Gun Temperature is consistent during all testing, this 
verification procedure must be performed prior to testing the first sensing element of 
each alarm set point and repeated after every four hours of testing or when the sensing 
element set point changes or when the ambient conditions in the test location change 
but not less than once per shift.
(a) Install the heat protection shield on the heat gun as shown in Figure 1.
(b) Connect the thermocouple to the Digital Mu ltimeter (DMM) or Digital Temperature 
Meter (DTM) and set the DMM or DTM to measure temperature.
(c) Turn on the heat gun and set airflow rate to maximum on the heat gun if the setting is 
available.

### Page 14

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 13 of 30 
 
(d) Place the thermocouple at the center of the heat protection shield, not touching the 
shield, at the approximate location the sensing element will be placed as shown in 
Figure 1 and Figure 2. 
(e) Set the heat gun temperature so that the thermocouple reads the Thermocouple Test 
Temperature value specified in Table 1 for the correct Salt Type Letter. 
 
NOTE: It is recommended that the Heat Gun setting temperature be initially set high 
enough such to achieve a Thermocouple Test Temperature that uses approximately ½ 
the allowable temperature tolerance defined in Table 1. 
 
NOTE: For Heat Guns with a digital display, the Heat Gun display temperature will 
typically be higher than the temperature at the thermocouple. 
 
NOTE: During Heat Gun Temperature Settings calibration to achieve the Thermocouple 
Test Temperature, the thermocouple temperature will slightly vary up and down 
according to the thermal regulation of the Heat Gun. The temperature values recorded 
should be the average of the observed results. 
 
(f) Verify and record that the center thermocouple temperature value is within the 
Thermocouple Test Temperature value tolerance specified in Table 1. 
(g) Move and place the thermocouple approximately 0.33 inch (0.85 cm) from the 
centerline of the heat protection shield left or right at the approximate location the 
sensing element will be placed as shown in Figure 1 and Figure 2. 
 
NOTE: If measuring the 2 nd location right of centerline, route thermocouple from the 
right. If measuring the 2 nd location left of centerline, route thermocouple from the left. 
 
NOTE: The Heat Gun 2 nd or off-axis location may be below the lower limit in the 
Table 1 as the temperature may reduce near the edges left or right of center test 
position.

### Page 15

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 14 of 30 
 
(h) Record the second or off-axis thermocouple value. 
(i) Calculate the two (2) point average temperature of the center point and second or off-
axis thermocouple readings. 
EXAMPLE 
Salt Type Letter 
Step 6 Center 
Thermocouple 
Temperature (T center) 
Step 2nd 
Thermocouple 
Temperature (T 2
nd
) 
2 pt Average 
Thermocouple  Test 
Temperature 
A 290 °F / 143 °C 260 °F / 127 °C 275 °F / 135 °C 
  
  FORMULA: 2pt Average Thermocouple Test Temperature 
    = (T center + T 2 nd)/2 
    = (290 °F + 260 °F)/2 
    = 275 °F 
 
(j) If the above 2 Point (pt) average Thermocouple Test Temperature value is not within 
the tolerance allowed in Table 1 using a Center and Left off axis position or Center and 
Right off axis position, attempt steps 4) through 9) trying the opposite side of the tested 
Center and Left or Right off axis position until the 2 Point (pt) average Thermocouple 
Test Temperature value is within the tolerance limits.  This will mitigate some heat gun 
variability. If the testing is not successful, replace the heat gun with one with a more 
uniform output. 
 
NOTE: It is recommended this value be near or approximately at the mid-point of the 
temperature range defined by the tolerance in Table 1. 
 
(k) Record the two (2) point average Thermocouple Test Temperature  verification 
temperature under the pre-test remarks Data Sheet in Table 2 (Refer Appendix A) for 
reference only. 
 
(2) For Center Wire Resistance (CWR) Measurements

### Page 16

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 15 of 30 
 
NOTE: CWR Measurements must be taken with an LCR meter and not a DMM. There 
a re Sensing Elem ent DC offset volta ge restrictions tha t a re required to be m a intained 
as well as electrical connection constraints to prevent Sensing Element polarization 
damage risk. 
 
o The LCR meter shall be configured as follows: 
 Measurement mode:  Resistance (R) 
 Range:  100 Ω or 200 Ω as applicable 
 
o The LCR meter shall be capable of meeting the following requirements: 
 Frequency:  1 kHz 
 Bias:  0.6-1.0 Vrms, 0 Vdc offset 
 
NOTE: These settings must be set at the meter if configurable or it must be confirmed 
that the meter is capable of these settings if not configurable. 
 
(3) For Salt Core Impedance (SCI) Measurements 
o The LCR meter shall be configured as follows: 
 Measurement mode:   Impedance (Z) 
 Heated range:  10 Ω or 10000 Ω as applicable 
 Room Tem perature Impedance range:  10000 Ω or 10MΩ as applicable 
o The LCR meter shall be capable of meeting the following requirements: 
 Frequency:  1 kHz 
 Bias:  0.6-1.0 Vrms, 0 Vdc offset 
 
CAUTION: When you do the test, do not use a meter that applies dc voltage. Do not 
use insulation resistance "megger" testers or dielectric voltage "hypot" testers. These 
will damage the sensing element. 
 
NOTE: These settings must be set at the meter, if configurable or it must be confirmed 
that the meter is capable of these settings if not configurable.

### Page 17

KIDDE AEROSPACE & DEFENSE
SERVICE BULLETIN
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR(CFD)–
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION
January 13/22 CFD-26-3
523-0832622
U.S. Export Classification: EAR 9E991
         Page 16 of 30
C. RC – Procedure - Bench Top Thermal Test
(1) Test locations
(a) Refer to Figure 4 below for test locations and test sections:
Figure 4. Test Locations for Compartment Overheat
(b) For sensing elements longer than 30 inch (76.2 cm) it shall be tested in three (3) 
locations. Testing shall NOT be performed within 1 inch (2.54 cm) of the connectors:
1) The 1 st location shall be from 2-14 inches (5-35 cm) from the beginning of the
sensing element and as close to the end as limits allow.  Each location will consist 
of 3 test points with a 3-4 inch (7.62 to 10.16 cm) center to center spacing between 
each test point. If the “Heated Impedance” Z value is below the Zeq(limit) for test 
point 1, test point 2, or test point 3, no additional test points within this test location
are required and can be entered directly on the data sheet as the final Zeq(Calc). 
If the “Heated Impedance” Z value is at or above the Zeq(limit) for all 3 test points, 
the Zeq(limit) will have to be calculated.
2) The 2 nd location shall be a location between 33% and 67% of the length of the 
sensing element AND at least 10 inches (25 cm) from the 1 st and 3rd test locations 
for sensing elements longer than 60 inches (152.4 cm). Each location will consist 
of 3 test points with a 3-4 inch (7.62 to 10.16 cm) center to center spacing between 
each test point. If the “Heated Impedance” Z value is below the Zeq(limit) for test 
point 1, test point 2, or test point 3, no additional test points within this test location 
are required and can be entered directly on the data sheet as the final Zeq(Calc). 
If the “Heated Impedance” Z value is at or above the Zeq(limit) for all 3 test points, 
the Zeq(limit) will have to be calculated.

### Page 18

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 17 of 30 
 
3) The 3 rd location shall be from 2-14 inches (5-35 cm) from the opposite end of the 
sensing element and as close to the end as limits allow.  Each location will consist 
of 3 test points with a 3-4 inch (7.62 to 10.16 cm) center to center spacing between 
each test point. If the “Heated Impedance” Z value is below the Zeq(limit) for test 
point 1, test point 2, or test point 3, no additional test points within this test location 
are required and can be entered directly on the data sheet as the final Zeq(Calc). 
If the “Heated Impedance” Z value is at or above the Zeq(limit) for all 3 test points, 
the Zeq(limit) will have to be calculated. 
(c) If the sensing element is between 14 - 30 inches (35 - 76.2 cm) long it shall be tested 
in two (2) locations. Testing shall NOT be performed within 1 inch (2.54 cm) of the 
connectors: 
1) The 1 st location shall be from 2-14 inches (5-35 cm) from the beginning of the 
sensing element and as close to the end as limits allow. Each location will consist 
of 3 test points with a 3-4 inch (7.62 to 10.16 cm) center to center spacing between 
each test point. If the “Heated Impedance” Z value is below the Zeq(limit) for test 
point 1, test point 2, or test point 3, no additional test points within this test location 
are required and can be entered directly on the data sheet as the final Zeq(Calc). 
If the “Heated Impedance” Z value is at or above the Zeq(limit) for all 3 test points, 
the Zeq(limit) will have to be calculated. 
2) The 2 nd location shall be from 2-14 inches (5-35 cm) from the end of the sensing 
element and as close to the end as limits allow. Each location will consist of 3 test 
points with a 3-4 inch (7.62 to 10.16 cm) center to center spacing between each 
test point. If the “Heated Impedance” Z value is below the Zeq(limit) for test point  
1, test point 2, or test point 3, no additional test points within this test location are 
required and can be entered directly on the data sheet as the final Zeq(Calc). If the 
“Heated Impedance” Z value is at or above the Zeq(limit) for all 3 test points,  the 
Zeq(limit) will have to be calculated. 
(d) Preformed and non-preformed sensing elements less than 14 inches (35 cm) shall be 
tested in one (1) location and at (1) test point furthermost distance from the connectors.  
Testing shall NOT be performed within 1 inch (2.54 cm) of the connectors.  Avoid 
aiming the heat gun at any grommets used to attach the sensing element if installed

### Page 19

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 18 of 30 
 
on a bracket.  In some instances, the heat gun flange must be removed in order to 
effectively execute the testing of the preformed sensing elements.  The preformed 
sensing elements shall be tested to the thermocouple test temperature identified in 
Table 1 plus 65°F (36°C). 
1) The 1 st and only (middle) location shall be in the middle area farthest from the 
beginning and end of the sensing element that has a width of approximately 1.5 to 
2.0 inches (3.81 to 5.08 cm). 
(2) Test article preparations 
(a) Remove the sensing element from packing material ensuring that the packing material 
is stored in a location where it will be shielded from the output of the heat gun. 
(b)  Uncoil the non-preformed sensing element to ensure access to the necessary start, 
middle, and end locations required for testing. Minimize bending to ensure easier re-
coiling and return to packaging. Ensure sensing elements are left straight and not bent 
for a minimum of 1 inch (2.54 cm) from rear hex nuts of the sensing element 
connectors. 
 
CAUTION: Do not uncoil/straighten preformed sensing elements. They cannot be 
easily re-formed without a precision fixture. 
 
(c)  Mark the test locations using a permanent ink marker. Refer to Section 3.C.(1) Test 
Locations for instructions on test locations. 
 
NOTE: Permanent Marker will not affect sensing element operation. It is not necessary 
to remove the markings after testing is complete. 
 
(d) Select test cable (P/N 1146006-0254-00) {Pin Style} or (1148006-0254-00) {Socket 
Style}, or test contact pin (P/N 349457), or [test contact pin (P/N 349457) and shell & 
insert assembly (P/N 476232)], which best mate with the sensing element under test. 
For sensing elements which are terminated with Lugs, the test lead can be clipped to 
the lug for the center wire connection and the sensing element sheath for the common 
connection.

### Page 20

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 19 of 30 
 
CAUTION: Use a connection cable or install a test pin in the socket connector to 
prevent damage to the sensing element connectors. 
 
(e) Turn on the LCR meter. If the meter is configurable, set the LCR meter to a test 
frequency of 1 kHz, DC bias to 0 VDC, signal amplitude to approximately 0.8 ±0.2 
Vrms, and measurement mode of “Z”. If t he meter is not configurable, using the meter 
specification sheet, ensure theses parameters are met on the LCR meter. 
(f) Connect the LCR meter for the appropriate measurement type as described below: 
For CWR measurements: 
1) Connect the center wire of the connecting cable (P/N 1146006-0254-00) {Pin Style} 
or (1148006-0254-00) {Socket Style}, or test contact pin (P/N 349457), or [test 
contact pin (P/N 349457) and shell & insert assembly (P/N 476232)], which best 
mate with the sensing element under test on one end of the sensing element to 
one terminal on the LCR meter. 
2) Connect the center wire of the connecting cable (P/N 1146006-0254-00) {Pin Style} 
or (1148006-0254-00) {Socket Style}, or test contact pin (P/N 349457), or [test 
contact pin (P/N 349457) and shell & insert assembly (P/N 476232)], which best 
mate with the sensing element under test on the other end of the sensing element 
to the other terminal on the LCR meter. 
 
NOTE: It is expected that the connecting cable impedance is less than 0.25 Ohms. It 
may be necessary to subtract the connecting cable impedance if the tolerances in 
Section 2.E.(2) Table are not met. 
 
For SCI measurements: 
1) Connect the center wire of the connecting cable (P/N 1146006-0254-00) {Pin Style} 
or (1148006-0254-00) {Socket Style}, or test contact pin (P/N 349457), or [test 
contact pin (P/N 349457) and shell & insert assembly (P/N 476232)], which best 
mate with the sensing element under test to the plus or positive terminal on the 
LCR meter

### Page 21

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 20 of 30 
 
2) Connect the negative terminal on the LCR meter to the shield of the connecting 
cable (P/N 1146006-0254-00) {Pin Style} or (1148006-0254-00) {Socket Style} or 
the sensing element tube near one connector (away from the area or end being 
heated).  
 
CAUTION: When connecting the cable to the sensing element, support the cable back 
shell with one hand and the sensing element end with the other, then twist the nut until 
tight. Do not twist the sensing element or the mating test cable if used. 
 
NOTE: If using a test cable, ensure that when the mating cable is connected from pin 
and/or socket connectors, that the mating cable is held so that it does not rotate while 
threading and connecting to the sensing element connector. An incremental threading 
and engagement pushing while holding the connector is required to ensure the mating 
cable is not twisting and damaging the core cables or mating pin contacts or shell and 
insert assemblies. Same for disconnecting except in reverse. 
 
(3) Test Set Up 
(a) For CWR measurements: 
1) Turn on the LCR meter.   
2) Refer to the LCR meter operating manual to set the required measurement test 
conditions. Typical example would be to set the measurement parameter by 
selecting or entering on the applicable meter buttons (example “L/C/R/Z”); settin g 
the measurement frequency by selecting or entering on the applicable meter 
buttons (example “FREQ”); setting the measurement AC amplitude by selecting or 
entering on the applicable meter buttons (example “AC”); and setting the 
measurement DC bias to 0 by selecting or entering on the applicable meter buttons 
(example “DC”);  
3) Set the LCR meter to Measurement parameter mode of “R”.  
4) Set the LCR meter measurement frequency to 1 kHz if configurable. If the meter is 
not configurable, using the meter specification sheet, ensure these parameters are 
met on the LCR meter.

### Page 22

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 21 of 30 
 
5) Set the LCR meter measurement AC amplitude to approximately 0.8 +/- 0.2 Vrms 
and DC bias or offset to 0 Vdc. If the meter is not configurable, using the meter 
specification sheet, ensure the LCR meter parameters in Section 2.E.(2) Table are 
met. 
6) Set the measurement range as applicable (1 00Ω or 200Ω) if applicable. 
7) Connect the LCR meter to the sensing element start and the sensing element end. 
 
NOTE:  It is expected that the connecting cable impedance is less than 0.25 Ohms. It 
may be necessary to subtract the connecting cable impedance if the tolerances in 
Section 2.E.(2) Table are not met. 
 
(b) For SCI measurements: 
1) If the meter is configurable, set the LCR meter to a test frequency of 1 kHz, ensure 
or set DC bias to 0Vdc, AC signal amplitude to approximately 0.8 +/- 0.2 Vrms, and 
measurement mode of “Z”. If the meter is not configurable, using the meter 
specification sheet, ensure these parameters are met on the LCR meter.  
2) Ensure the LCR meter is connected to the sensing element start/end and the 
sensing element ground (sensing element tube). 
 
CAUTION: When you do the test, do not use a meter that applies dc voltage. Do not 
use insulation resistance "megger" testers or dielectric voltage "hypot" testers. These 
will damage the sensing element. 
 
(4) Test Procedure 
(a) Enter the top section information (P/N, S/N, date, temperature, Pre Test Remarks, etc.) 
and record the results on the applicable Data Sheet in Table 2 (Refer Appendix A).

### Page 23

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 22 of 30 
 
Table 1: Heat Gun Temperature Settings 
Salt 
Type 
Letter 
Salt Temp  Thermocouple Test Temperature* Family PN Zeq ohms 
A 255 °F / 124 °C 275 ( -0,+30) °F / 135 (- 0,+17) °C 
1070001 148 
1072001 148 
04-90014 148 
ALL OTHERS 127 
C 310 °F / 154 °C 332 ( -0,+30) °F / 167 (- 0,+17) °C 1072001 81 
ALL OTHERS 68 
D 400 °F / 204 °C 427 -0,+30) °F / 219 (-0,+17) °C ALL 97 
M 180 °F / 82 °C 196 -0,+30) °F / 91 (-0,+17) °C ALL 128 
R 356 °F / 180 °C 381 (-0,+30) °F / 194 (-0,+17) °C ALL 81 
* For preformed sensing elements 14” (35 cm) or less, the Thermocouple Test 
Temperature will be the value stated in Table 1 plus 65 °F (36 °C) 
 
Note:  The Salt Type is designated by the P/N in one of two ways: 
The letter in the P/N (i.e. 04-90014-9238A is Salt Type “A”) 
The end dash number (i.e. 35535-2-310 is Salt Type “C”) 
P/N’s 04 -90016-901, 04-90016-902, 1094006-046, & 1095006-046 are 
Salt Type “R” 
 
WARNING: If the hot air is set above 392 °F (200 °C), ensure the surroundings are 
free of fuel vapors and other ignition sources. 
 
(b) Measure the Center Wire Resistance and log the value in the Data Sheet Table 2 
(Refer Appendix A). 
(c) Turn on the heat gun and set and verify the temperature at the interval frequency per 
Section 3.B. using the thermocouple temperature values specified in Table 1. Allow 
the heat gun to preheat for a minimum of 30 seconds (0.5 minutes) and must reach 
proper stable test temperature. Ensure that the exhaust of the heat gun is directed in 
a safe direction. Refer to individual P/N top level drawings to determine salt type . 
(d) Measure and record the “Room Temperature Impedance” using the LCR meter  and  
SCI Measurement criteria. The value must be ≥ 10 k Ω and < 3M Ω. Log the value on 
the Data Sheet Table 2 (Refer Appendix A). Refer to Section 3.C.(5).(b). Post Test for 
values that are out of tolerance.

### Page 24

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 23 of 30 
 
NOTE: If the “Room Temperature Impedance” is ≥ 3M Ω check LCR meter lead 
continuity by shorting leads together and then verify LCR meter to sensing element 
lead connections and retest if necessary. 
 
(e) Heat the 1 st test point in the first test location for a minimum of 60 seconds (1 minute) 
and no more than 120 seconds (2 minutes). Refer to Section 3.B.(4).(a) Test Locations   
for instructions on test locations. 
 
NOTE: If the “Heated Impedance” is below the Zeq(limit) for five (5) or more seconds 
prior to 60 seconds, the full 60 seconds wait time is NOT required (can proceed to next 
test location). 
 
NOTE: For optimum test execution it is best to measure the CWR value first, then 
calculate the Zeq(limit). Perform the individual heated test points and assess if they 
are below the Zeq(limit).  If not, continue heating additional local test points up to three 
(3) total before advancing to the next test location of the sensing element.  Individual 
Z re adings are not required to be ≤ Zeq(limit).  Individual Z readings must be >0.4 Ω 
and < 3 M Ω (the upper room temperature impedance limit).  Repeat the same testing 
method until all three (3) test locations of the sensing element are tested. Then go 
back and perform the Zeq(Calc) math calculations to assess pass/fail. 
 
(f) Measure and record the “Heated Impedance” using the LCR meter  and SCI  
Measurement criteria. Repeat Steps e) to g) for a total of three (3) times within this test 
location area (3 readings) with a 3 to 4 inch (7.62 to 10.16 cm) spacing. 
 
NOTE: If the “Heated Impedance” Z value is below the Zeq(limit) for test point 1, test point 
2, or test point 3, no additional test points within this test location are required and can be 
entered directly on the data sheet as the final Zeq(Calc). 
 
(g) Record each value on the Data Sheet and then use the values to calculate the 
Zeq(calc) value using the formula below:

### Page 25

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 24 of 30 
 
Zeq(Calc) = 1 / {(1/Z 1 + 1/Z2 + 1/Z3)} 
 
The Zeq(calc) value must be less than the Zeq(limit) value.  Zeq(limit) = Zeq(snsr) from 
Table 1 for the salt type sensing element + ½ * CWR measured value in ohms and 
greater than 0.4 Ω. 
 
EXAMPLE:  Target Limit = 127 Ω  CWR = 4 Ω 
   Zeq(Calc) < 127 + 4/2 Zeq(Calc) < 129 
   Z 1 = 170 Ω Z 2 = 400 Ω Z 3 = 1200 Ω 
   Zeq(Calc) = 1 / {(1/170 + 1/400 + 1/1200)} 
   Zeq(Calc) = 108 Ω  Unit Passes  
 
NOTE: The calculation is derived to account for differences between this test 
procedure and the Acceptance Test Procedure (ATP). 
 
(h) Log the Zeq(limit) and Zeq(calc) value on the Data Sheet Table 2 (Refer Appendix A). 
 
NOTE: The Zeq(Calc) value may be calculated once all 3 test points within a test 
location are complete. It is not required to calculate Zeq(Calc) before moving on from 
a single test location. 
 
(i) Remove the heat gun from sensing element and let it cool for three (3) minutes or until 
the “Room Temperature Impedance” is above the limit (see next step). Wipe the 
sensing element with a damp cloth to restore it to room temperature. 
1) If the sensing element does not result in a Zeq value less than the limit with the 
heat gun applied, then check the connections and repeat Steps c) thru g) and if 
necessary change the test connection to the sensing element to the end nearest 
the test location. 
2) If the sensing element does not result in a Zeq value less than the limit with the 
heat gun applied upon retest, then refer to Section 3.C.(5).(b) Post Test for values 
that are out of tolerance.

### Page 26

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 25 of 30 
 
NOTE: If the “Room Temperature Impedance” increases abov e the limit for five (5) or 
more seconds prior to three (3) minutes with the damp cloth removed, the full three (3) 
minutes wait time is NOT required (can proceed to next test location). 
 
(j) Measure and record the “Room Temperature Impedance” using the LCR me ter and 
SCI Measurement criteria. The value must be between 10 kΩ and 3MΩ. Log the value 
on the Data Data Sheet Table 2 (Refer Appendix A). Refer to Section 3.C.(5).(b) Post 
Test for values that are out of tolerance. 
(k) Heat the 1 st test point in the second test location for a minimum of 60 seconds (1 
minute) and no more than 120 seconds (2 minutes). Refer to Section 3.B.(4).(a)  Test 
Locations for instructions on test locations. 
 
NOTE: If the “Heated Impedance” is below the Zeq (limit) for five (5) or more seconds 
prior to 60 seconds, the full 60 seconds wait time is NOT required (can proceed to next 
test location). 
 
NOTE: For optimum test execution it is best to measure the CWR value first, then 
calculate the Zeq(limit). Perform the individual heated test points and assess if they 
are below the Zeq(limit).  If not, continue heating additional local test points up to three 
(3) total before advancing to the next test location of the sensing element.  Individual 
Z readings are not required to be ≤ Zeq(limit).  Individual Z readings must be >0.4 Ω 
and < 3 M Ω (the upper room temperature impedance limit).  Repeat the same testing 
method until all three (3) test locations of the sensing element are tested. Then go 
back and perform the Zeq(Calc) math calculations to assess pass/fail. 
 
(l) Measure and record the “Heated Impedance” using the LCR meter  and SCI  
Measurement criteria. Repeat Steps k) thru m) for a total of three (3) times within this 
test location area (3 readings) with a 3 to 4 inch (7.62 to 10.16 cm) spacing.

### Page 27

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 26 of 30 
 
NOTE: If the “Heated Impedance” Z value is below the Zeq(limit) for test point 1, test 
point 2, or test point 3, no additional test points within this test location are required 
and can be entered directly on the data sheet as the final Zeq(Calc). 
(m) Record each value on the data sheet and then use the values to calculate the Zeq(calc) 
value using the formula below: 
 
Zeq(Calc) = 1 / {(1/Z 1 + 1/Z2 + 1/Z3)} 
 
The Zeq(calc) value must be less than the Zeq(limit) value.  Zeq(limit) = Zeq(snsr) from 
Table 2 for the salt type sensing element + ½ * CWR measured value in ohms and 
greater than 0.4 Ω. 
(n) Log the Zeq(limit) and Zeq(calc) value on the Data Sheet Table 2 (Refer Appendix A). 
 
NOTE: The Zeq(Calc) limit may be calculated once all three (3) test points on a sensing 
element are complete.  It is not required to calculate Zeq(Calc) before moving on from 
a test location. 
 
(o) Remove the heat gun from sensing element and let it cool for at least 3 minutes. A 
damp cloth can be used to restore sensing element to room temperature. 
1) If the sensing element does not result in a Zeq value less than the limit with the 
heat gun applied, then check the connections and repeat steps j) through m) and 
if necessary change the test connection to the sensing element to the end nearest 
the test location. 
2) If the sensing element does not result in a Zeq value less than the limit with the 
heat gun applied upon retest, then refer to Section 3.C.(5).(b) Post Test for values 
that are out of tolerance. 
 
NOTE: If the “Room Temperature Impedance” increases above the limit for five (5) or 
more seconds prior to three (3) minutes with the damp cloth removed, the full three (3) 
minutes wait time is NOT required (can proceed to next test location).

### Page 28

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 27 of 30 
 
(p) Measure and record the “Room Temperature Impedance” using the LCR meter  and  
SCI Measurement criteria. The value must be ≥ 10 k Ω and < 3  MΩ. Log the value on 
the Data Sheet Table 2 (Refer Appendix A). Refer to Section 3.C.(5).(b) Post Test for 
values that are out of tolerance. 
(q) Heat the 1 st test point in the third test location for a minimum of 60 seconds (1 minute) 
and no more than 120 seconds (2 minutes). Refer to Section 3.B.(4).(a) Test Locations 
for instructions on test locations. 
 
NOTE: If the “Heated Impedance” is below the Zeq limit for 5 or more seconds prior to 
60 seconds, the full 60 seconds wait time is NOT required (can proceed to next test 
location). 
 
NOTE: For optimum test execution it is best to measure the CWR value first, then 
calculate the Zeq(limit). Perform the individual heated test points and assess if they 
are below the Zeq(limit).  If not, continue heating additional local test points up to three 
(3) total before advancing to the next test location of the sensing element.  Individual 
Z readings are not required to be ≤ Zeq(limit).  Individual Z readings must be >0.4 Ω 
and < 3 M Ω (the upper room temperature impedance limit).  Repeat the same testing 
method until all three (3) test locations of the sensing element are tested. Then go 
back and perform the Zeq(Calc) math calculations to assess pass/fail. 
 
(r) Measure and record the “Heated Impedance” using the LCR meter  and SCI  
Measurement criteria. Repeat Steps q) thru s) for a total of three (3) times within this 
test location area (3 readings) with a 3 to 4 (7.62 to 10.16 cm) inch spacing. 
 
NOTE: If the “Heated Impedance” Z value is below the Zeq(limit) for test point 1, test 
point 2, or test point 3, no additional test points within this test location are required 
and can be entered directly on the data sheet as the final Zeq(Calc). 
 
(s) Record each value on the data sheet and then use the values to calculate the Zeq(calc) 
value using the formula below:

### Page 29

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 28 of 30 
 
Zeq = 1 / {(1/Z 1 + 1/Z2 + 1/Z3)} 
 
The Zeq(calc) value must be less than the Zeq(limit) value. Zeq(limit) = Zeq(snsr) from 
Table 1 for the salt type sensing element + ½ * CWR measured value in Ohms and 
greater than 0.4 Ω. 
(t) Log the Zeq(limit) and Zeq(calc) value on the Data Sheet Table 2 (Refer Appendix A). 
 
NOTE: The Zeq(Calc) limit may be calculated once all 3 test points on a sensing 
element are complete. It is not required to calculate Zeq(Calc) before moving on from 
a test location . 
 
(u) Remove the heat gun from sensing element and let it cool for at least 3 minutes. A 
damp cloth can be used to restore sensing element to room temperature. 
1) If the sensing element does not result in a Zeq value less than the limit with the 
heat gun applied, then check the connections and repeat Steps p) thru s) and if 
necessary change the test connection to the sensing element to the end nearest 
the test location.  
2) If the sensing element does not result in a Zeq value less than the limit with the 
heat gun applied upon retest, refer to Section 3.C.(5).(b) Post Test for values that 
are out of tolerance. 
(v) Measure and record the “Room Temperature Impedance” after testing the third sensing 
element test location using the LCR meter and SCI Measurement criteria. The value 
must be ≥ 10 kΩ and < 3 MΩ. Log the value on the Data Sheet Table 2 (Refer Appendix 
A). Refer to Section 3.C.(5).(b) Post Test for values that are out of tolerance. 
(w) Run the heat gun on fan only mode for at least five (5) minutes to cool, then turn off 
the heat gun. 
(x) Ensure all data is logged on the Data Sheet Table 2 (Refer Appendix A). 
 
(5) Post test 
(a) Verify that all sensing element impedance (Z and Zeq(Calc))  measurements are within 
the applicable value limits listed in the attached Data Sheet Table 2 (Refer Appendix

### Page 30

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 29 of 30 
 
A). Verify that all test result entries are completed, passing results for each sensing 
element test location or sensing elements tested, and sensing element impedance (Z 
and Zeq(Calc)) measurements are within applicable value limits. 
(b) Any unit that does not meet all requirements of  Section 3.C. Test Procedure, does not 
meet the requirements of Federal Aviation Administration (FAA) Technical Standard 
Order (TSO)-C11e, is not airworthy and cannot be installed on an aircraft. Mark the 
“Reject” box at the bottom of  Table 2 (Refer Appendix A). 
(c) Ensure that the sensing element has returned to ambient temperature. 
(d) Remove LCR meter test leads. Inspect the connector both ends of the CFD sensing 
element for damage. Replace the sensing element connector caps if applicable. 
(e) Continue to Step 3.D. Identification Procedure. 
D. RC - Re-identification of Equipment 
(1) If the element fails any of the tests, continue to Section 3.D.(4). 
(2) For conforming material, mark one face of the connector hex nut. 
(3) Carefully recoil the sensing element to the same original coil diameter (approximately 7.5 
inch), taking minimum bend radius into consideration (no kinks permitted), free from bends 
within 1 inch (2.54 cm) of hex nut of sensing element connectors, and replace it in the 
original packaging material. 
 
NOTE: Minimum Bend radius is 1 inch (2.54 cm). 
 
(4) Apply a dot to the exterior packaging and insert a copy of the Test Datasheet in the 
packaging. 
 
NOTE: The identification procedure must be accomplished in order for the service bulletin 
to be complete. 
 
If unit fails testing, send unit to address below with Record of Accomplishment form f illed 
out. Any unit that fails any portion of the test must not be installed/re-installed on an 
aircraft.

### Page 31

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
U.S. Export Classification: EAR 9E991 
         Page 30 of 30 
 
Collins Aerospace 
Attn: CFD NOE Return 
4200 Airport Dr. 
Wilson, NC 27896 
 
TELEPHONE: 1.888.265.5467 
INTERNATIONAL: 1.319.295.5467 
FAX NO: 1.319.295.4941 
 
Email: kiddeCFDreturns@collins.com  
 
(5)  Record of Accomplishment 
(a) Record the test results on the form in Appendix A. 
 
NOTE: At the discretion of the OEM/customer, send the Record of Accomplishment to: 
 
Email: AvionicsSupport@collins.com 
E. Test 
Refer to Section 3.C. RC – Procedure - Bench Top Thermal Test 
 
F. Close-Up 
Not Applicable

### Page 32

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
 
U.S. Export Classification: EAR 9E991 
         Appendix A 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
APPENDIX A

### Page 33

KIDDE AEROSPACE & DEFENSE 
SERVICE BULLETIN 
FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) – 
AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER 
OPERATION 
 
January 13/22 CFD-26-3 
523-0832622 
 
U.S. Export Classification: EAR 9E991 
         Appendix A 
 
Test Datasheet - Bench Top Thermal Test 
P/N:   Date: ____________  
S/N – Date Code:   Pre Test Remarks: ____________________________________________________ 
Test Site Ambient Conditions:      Temperature:   °F (°C) 
Pre-test sensing element CWR   (30 Ω max)   
Location 
(PN, MID, SN) 
Description 
Target 
Z or Zeq(limit) 
(Ω) 
Measured 
Z 
 (Ω)  
Calculated  
Zeq(Calc)  
(Ω) 
PASS/FAIL 
(Circle One) 
Pre-Location 1 Room Temperature Impedance (Z) 
≥ 10 k Ω & 
 < 3 M Ω 
 N/A 
Pass 
Fail 
Location 1  
(         ) 
Heated Impedance(Z) / Zeq(Calc) 
(Zeq(limit) = Zeq(Snsr) from  Table 1 
+ ½*CWRmeas  
> 0.4 Ω & 
≤ Zeq(Snsr) +  
½ CWR meas Ω 
≤ _______ 
*Z1=    
 Pass 
Fail 
*Z2= 
*Z3= 
Pre-Location 2 Room Temperature Impedance (Z) 
≥ 10 k Ω & 
 < 3 M Ω 
 N/A 
Pass 
Fail 
Location 2  
(         ) 
Heated Impedance(Z) / Zeq(Calc) 
(Zeq(limit) = Zeq(Snsr) from  Table 1 
+ ½*CWRmeas  
> 0.4 Ω & 
≤ Zeq(Snsr) +  
½ CWR meas Ω 
≤ _______ 
*Z1=    
 Pass 
Fail *Z2= 
*Z3= 
Pre-Location 3 Room Temperature Impedance (Z) ≥ 10 k Ω & 
 < 3 M Ω 
 N/A Pass 
Fail 
Location 3  
(         ) 
Heated Impedance(Z) / Zeq(Calc) 
(Zeq(limit) = Zeq(Snsr) from  Table 1 
+ ½*CWRmeas 
> 0.4 Ω & 
≤ Zeq(Snsr) +  
½ CWR meas Ω 
≤ _______ 
*Z1=    
 Pass 
Fail 
*Z2= 
*Z3= 
 
Post Test  Room Temperature Impedance (Z) ≥ 10 k Ω &  < 3 M Ω  N/A Pass Fail 
 
Sensing Element  Performance:    Accept [  ]    Reject [  ] 
 
Test Technicia n:  Date:    
 
Test Witness:   Date:    
*Individual Z readings are not required to be ≤ Zeq(limit). Individual Z readings must be >0.4 Ω and < 3 M Ω (the upper room 
temperature impedance limit). 
  Table 2: Test Datasheet - Bench Top Thermal Test

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.