# Leonardo Alert Service Bulletin 109S-122: No revision named

- Rights: © Leonardo S.p.A. Filed by the FAA in regulations.gov docket FAA-2025-0020, the docket of AD 2025-09-10. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Leonardo Alert Service Bulletin 109S-122](https://openairdocs.org/service-documents/leonardo/109s-122.md)
- Title as filed: Leonardo ASB 109S-122
- Pages: 14
- PDF: https://openairdocs.org/files/sha256/ba/20/ba2064eaffce7a64a9738221a7ed346105c923a4d447f85694a343ef47b8661c
- Page: https://openairdocs.org/service-documents/leonardo/109s-122/file/ba2064eaffce

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

Page 1 of 13 
N°  109S-122 
DA TE:  September 30, 2024 
REV. :  / - December 22, 2023 
TITLE 
ATA 26 – ENGINE FIRE EXTINGUISHER BOTTLES ELECTRICAL CONNECTIONS 
I
NSPECTION 
REVISION LOG 
First Issue 
An appropriate entry should be made in the aircraft log book upon accomplishment.
If ownership of aircraft has changed, please, forward to new owner.
Leonardo S.p.A.
Via Giovanni Agusta, 520
21017 Cascina Costa di Samarate (VA) Italy
Tel.: +39 0331 229111 - Fax: +39 0331 229605/222595
ALERT
SERVICE BULLETIN

### Page 2

S.B. N°109S-122 ALERT 
 DATE: September 30, 2024 
Page 2 of 13 REVISION: / 
1. PLANNING INFORMATION 
A. EFFECTIVITY 
 All A109S helicopters. 
 All A109S helicopters with Trekker Kit up to S/N 22748 (included), except 
S/N 22742 and S/N 22747. 
B. COMPLIANCE 
Within and not later than 50 flight hours or 3 months whichever occurs first after the 
issue of this Service Bulletin. 
C. CONCURRENT REQUIREMENTS 
N.A. 
D. REASON 
Leonardo Helicopters issued this Service Bulletin following an occurrence reporting an 
improper installation of the MTR cables and the bonding braids connected to the fire 
extinguisher bottles. 
This Service Bulletin provides instructions on how to inspect the fire extinguisher bottles 
wirings installation and restore the proper configuration, if needed. 
E. DESCRIPTION 
This Service Bulletin provides the instructions to perform a one-off inspection of both 
LH and RH engine fire extinguisher bottles to make sure that the MTR cables and the 
bonding braids are properly connected to the cartridge of the bypass valve and single 
outlet valve of the bottles. In case of improper installations, the Service Bulletin 
prescribes to restore the correct installation according to design. 
F. APPROVAL 
The technical content of this Service Bulletin is approved under the authority of DOA 
nr. EASA.21.J.005. For helicopters registered under other Aviation Authorities, before 
applying the Service Bulletin, applicable Aviation Authority approval must be checked 
within Local Aviation Authority. 
EASA states mandatory compliance with inspections, modifications or technical 
directives and related time of compliance by means of relevant Airworthiness 
Directives.

### Page 3

S.B. N°109S-122 ALERT 
DATE: September 30, 2024 
REVISION: / Page 3 of 13 
If an aircraft listed in the effectivity embodies a modification or repair not Leonardo 
Helicopters certified and affecting the content of this Service Bulletin, it is responsibility 
of the Owner/Operator to obtain a formal approval by Aviation Authority having 
jurisdiction on the aircraft, for any adaptation necessary before incorporation of the 
present Service Bulletin. 
G. MANPOWER 
To comply with this Service Bulletin, approximately one (1) MMH are deemed 
necessary (ONLY for the inspection procedure). 
MMH are based on hands-on time and can change with helicopter configuration, 
personnel and facilities available. MMH are not comprehensive of the overall hours 
necessary to get access to work areas and to remove all the equipment that interferes 
with the application of the prescribed instructions. 
H. WEIGHT AND BALANCE 
N.A. 
I. REFERENCES 
I.1 PUBLICATIONS 
Following Data Modules refer to AMP: 
DATA MODULE DESCRIPTION PART 
DM01 0B-A-00-20-00-00A-120A-A Helicopter safety – 
Preoperation 
- 
DM02 0B-A-06-41-00-00A-010A-A Access doors and panels – 
General data 
- 
DM03 0B-A-26-21-01-00A-520A-A Number 1 fire extinguishing 
bottle - Remove procedure 
- 
DM04 0B-A-26-21-01-00A-720A-A Number 1 fire extinguishing 
bottle - Install procedure 
- 
DM05 0B-A-26-22-01-00A-520A-A Number 2 fire extinguishing 
bottle - Remove procedure 
- 
DM06 0B-A-26-22-01-00A-720A-A Number 2 fire extinguishing 
bottle - Install procedure 
- 
 
Following Data Modules refer to AWDP: 
DATA MODULE DESCRIPTION PART 
DM07 0B-A-26-00-00-00A-051A-A Fire protection system - Wiring 
diagram 
- 
DM08 0B-K-26-00-00-00A-051A-A Fire protection system - Wiring 
diagram 
-

### Page 4

S.B. N°109S-122 ALERT 
 DATE: September 30, 2024 
Page 4 of 13 REVISION: / 
DATA MODULE DESCRIPTION PART 
DM09 0B-K-26-00-00-00B-051A-A Fire protection system - Wiring 
diagram 
- 
 
I.2 ACRONYMS & ABBREVIATIONS 
AMP Air vehicle Maintenance information 
AR As Required 
AWDP Air Vehicle Wiring Data information 
BP Bypass 
DM Data Module 
DOA Design Organization Approval 
EASA European Union Aviation Safety Agency 
IPD Illustrated Parts Data information 
ITEP Illustrated Tool and Equipment Publication 
LH Left Hand 
MMH Maintenance Man Hours 
MTR Motor 
N.A. Not Applicable 
P/N Part Number 
RH Right Hand 
SB Service Bulletin 
S/N Serial Number 
SO Single Outlet 
I.3 ANNEX 
N.A. 
J. PUBLICATIONS AFFECTED 
A109S/AW109SP Air vehicle Maintenance information (AMP) 0B-A-AMP-00-X 
K. SOFTWARE ACCOMPLISHMENT SUMMARY 
N.A.

### Page 5

S.B. N°109S-122 ALERT 
DATE: September 30, 2024 
REVISION: / Page 5 of 13 
2. MATERIAL INFORMATION 
A. REQUIRED MATERIALS 
A.1 PARTS 
N.A. 
A.2 CONSUMABLES 
N.A. 
A.3 LOGISTIC MATRIX 
N.A. 
NOTES 
N.A. 
B. SPECIAL TOOLS 
Refer to ITEP for the special tools required to comply with the AMP DMs referenced in 
the accomplishment instructions. 
SPECIAL TOOLS NOTES 
N.A. 
C. INDUSTRY SUPPORT INFORMATION 
N.A.

### Page 6

S.B. N°109S-122 ALERT 
 DATE: September 30, 2024 
Page 6 of 13 REVISION: / 
3. ACCOMPLISHMENT INSTRUCTIONS 
GENERAL NOTES 
a) Place an identification tag on all components that 
are re-usable, including the attaching hardware that 
has been removed to gain access to the modification 
area and adequately protect them until their later re-
use. 
b) Please refer to “LH fire extinguishing bottle” as 
“Number 1 fire extinguishing bottle” and refer to “RH 
fire extinguishing bottle” as “Number 2 fire 
extinguishing bottle”. 
1. In accordance with AMP DM 0B-A-00-20-00-00A-120A- A, prepare the helicopter on 
ground for a safe maintenance. Disconnect the battery, all electrical power sources and/or 
the external power supply. 
2. In accordance with AMP DM 0B-A-06-41-00-00A-010A-A and with reference to Figure 1, 
remove the external panel P18 to gain access to the area affected by the inspection. 
WARNING 
THE MTR CABLE MUST BE CONNECTED TO THE 
CONNECTOR ON THE HEAD OF THE CARTRIDGE 
(POSITIVE TERMINAL OF THE CARTRIDGE, RED 
CIRCLE IN FIGURE 1). 
THE BONDING BRAID MUST BE CONNECTED TO 
THE CONNECTOR ON THE SIDE OF THE 
CARTRIDGE (NEGATIVE TERMINAL OF THE 
CARTRIDGE, BLUE CIRCLE IN FIGURE 1). 
3. In accordance with the following procedure and wi th reference to Figure 1 thru Figure 3, 
verify that the MTR cables and the bonding braids are correctly installed on the cartridges 
of the fire extinguisher bottles both on LH and RH side: 
3.1 With reference to Figure 1, make sure that the bonding braids are connected in the 
proper positions on the LH fire extinguisher bottle.

### Page 7

S.B. N°109S-122 ALERT 
DATE: September 30, 2024 
REVISION: / Page 7 of 13 
NOTE 
The MTR1 cable must be connected to the connector on 
the head of the cartridge on the Bypass Valve. 
The MTR2 cable must be connected to the connector on 
the head of the cartridge on the Single Outlet Valve. 
3.2 With reference to AWDP DM 0B-A-26-00-00-00A-051A -A or  
DM 0B-K-26-00-00-00A-051A-A or DM 0B-K-26-00-00-00B-051A-A, as applicable, 
and Figure 3, make sure that the MTR1 and MTR2 cables are connected in the 
proper positions on the LH fire extinguisher bottle. 
3.3 With reference to Figure 1, make sure that the bonding braids are connected in the 
proper positions on the RH fire extinguisher bottle. 
NOTE 
The MTR1 cable must be connected to the connector on 
the head of the cartridge on the Single Outlet Valve. 
The MTR2 cable must be connected to the connector on 
the head of the cartridge on the Bypass Valve. 
3.4 With reference to AWDP DM 0B-A-26-00-00-00A-051A -A or  
DM 0B-K-26-00-00-00A-051A-A or DM 0B-K-26-00-00-00B-051A-A, as applicable, 
and Figure 2, make sure that the MTR1 and MTR2 cables are connected in the 
proper positions on the RH fire extinguisher bottle. 
WARNING 
THE MTR CABLE MUST BE CONNECTED TO THE 
CONNECTOR ON THE HEAD OF THE CARTRIDGE 
(POSITIVE TERMINAL OF THE CARTRIDGE, RED 
CIRCLE IN FIGURE 1). 
THE BONDING BRAID MUST BE CONNECTED TO 
THE CONNECTOR ON THE SIDE OF THE 
CARTRIDGE (NEGATIVE TERMINAL OF THE 
CARTRIDGE, BLUE CIRCLE IN FIGURE 1). 
4. In case any improper installation was identified while performing step 3, restore the proper 
connections in accordance with the following procedure: 
4.1 In case of any finding was detected on LH side (while performing steps 3.1 
and 3.2): 
4.1.1 In accordance with the applicable steps of AMP  
DM 0B-A-26-21-01-00A-520A-A, disconnect the affected bonding 
braid(s) and MTR cable(s) from the cartridge(s).

### Page 8

S.B. N°109S-122 ALERT 
 DATE: September 30, 2024 
Page 8 of 13 REVISION: / 
NOTE 
The MTR1 cable must be connected to the connector on 
the head of the cartridge on the Bypass Valve. 
The MTR2 cable must be connected to the connector on 
the head of the cartridge on the Single Outlet Valve. 
4.1.2 In accordance with the applicable steps of AMP   
DM 0B-A-26-21-01-00A-720A-A and with reference to Figure 1 View A 
and Figure 3, reinstall the bonding braid(s) and the MTR cable(s) in the 
correct position on the cartridge(s). 
4.2 In case of any finding was detected on RH side (while performing steps 3.3 
and 3.4): 
4.2.1 In accordance with the applicable steps of AMP  
DM 0B-A-26-22-01-00A-520A-A, disconnect the affected bonding 
braid(s) and the MTR cable(s) from the cartridge(s). 
NOTE 
The MTR1 cable must be connected to the connector on 
the head of the cartridge on the Single Outlet Valve. 
The MTR2 cable must be connected to the connector on 
the head of the cartridge on the Bypass Valve. 
4.2.2 In accordance with the applicable steps of AMP   
DM 0B-A-26-22-01-00A-720A-A and with reference to Figure 1 View A 
and Figure 2, reinstall the bonding braid(s) and the MTR cable(s) in the 
correct position on the cartridge(s). 
NOTE 
“XXXXX” in the subject line below is the helicopter S/N. 
5
. Compile the Inspection Report Form in Figure 4 and send it with Subject line  
“SB 109S-122 – S/N XXXXX Inspection Report Form” to the following mail box: 
 engineering.support.lhd@leonardo.com  
and (for North, Central and South America) also to: 
   AWPC.Engineering.Support@leonardocompany.us. 
6. In accordance with AMP DM 0B-A-06-41-00-00A-010A-A, re-install the external panel P18 
previously removed. 
7. Return the helicopter to flight configuration and record for compliance with this Service 
Bulletin on the helicopter logbook.

### Page 9

S.B. N°109S-122 ALERT 
DATE: September 30, 2024 
REVISION: / Page 9 of 13 
8. Gain access to My Communications section on Leonardo Customer Portal and compile 
the “Service - Technical Bulletin Application”. 
As an alternative, send the attached compliance form to the following mail box: 
 engineering.support.lhd@leonardo.com  
and (for North, Central and South America) also to: 
 AWPC.Engineering.Support@leonardocompany.us 
  Non cancellare mai questo segnalibro Non cancellare mai interruzione sezione 

### Page 10

Figure 1 
 S.B. N°109S-122 ALERT 
 DATE: September 30, 2024 
Page 10 of 13 REVISION: / 
 
VIEW A
MTR CABLES ARE NOT SHOWN
STRUCTURE AND SYSTEMS ARE PARTIALLY OMITTED FOR BETTER CLARITY PURPOSE
 A 
BONDING BRAID
(REF)
27300-1 LH FIRE EXTINGUISHING BOTTLE
(REF)
27300-1 RH FIRE EXTINGUISHING BOTTLE
(REF)
BONDING BRAID
(REF)
BONDING BRAID
(REF)
MTR CONNECTION (REF)
(TYP 2 PLCS)
BONDING CONNECTION (REF)
(TYP 2 PLCS)
MTR CONNECTION (REF)
(TYP 2 PLCS)
BONDING CONNECTION (REF)
(TYP 2 PLCS)
BONDING BRAID
(REF)
RH SIDE LH SIDE
CL HELICOPTER
BP VAL VE
(REF)
BP VALVE
(REF)
SO VALVE
(REF)
SO VALVE
(REF)
CARTRIDGE
 (REF)
CARTRIDGE
 (REF) CARTRIDGE
 (REF)
CARTRIDGE
 (REF)
DETAIL B (SEE ALSO FIGURE 2) DETAIL C (SEE ALSO FIGURE 3)

### Page 11 (OCR)

LEONARDO
HELICOPTERS
RH ENGINE FIRE EXTINGUISHING BOTTLE (REF)
MTR2 CABLE (W216A20 or 113)
BP VALVE (REF)  (REF)
SN. 0245
SO VALVE (REF)
MTR1 CABLE (W207A20 or 117)
(REF)
DETAIL B
FOR REFERENCE ONLY
Figure 2
S.B. N°109S-122 ALERT
DATE: September 30, 2024
REVISION: /  Page 11 of 13

### Page 12 (OCR)

: LEONARDO
HELICOPTERS
LH ENGINE FIRE EXTINGUISHING BOTTLE (REF)
MTR2 CABLE (W217A20 or 132)
(REF)
SO VALVE (REF)
MTR1 CABLE (W208A20 or 131)
(REF)
BP VALVE (REF)
DETAIL C
FOR REFERENCE ONLY
Figure 3
S.B. N°109S-122 ALERT
DATE: September 30, 2024
Page 12 of 13  REVISION: /

### Page 13

Figure 4 
S.B. N°109S-122 ALERT 
DATE: September 30, 2024 
REVISION: / Page 13 of 13 
 
SB 109S-122 Rev. / – INSPECTION REPORT FORM 
DATE  
HELICOPTER S/N  
CUSTOMER  
LH ENGINE FIRE EXTINGUISHER 
BOTTLE ELECTRICAL 
CONNECTIONS 
MTR1 CABLE AND BONDING 
BRAID INSTALLATION 
MTR2 CABLE AND BONDING 
BRAID INSTALLATION 
☐ CORRECT 
☐ NOT CORRECT 
☐ CORRECT 
☐ NOT CORRECT 
RH ENGINE FIRE EXTINGUISHER 
BOTTLE ELECTRICAL 
CONNECTIONS 
MTR1 CABLE AND BONDING 
BRAID INSTALLATION 
MTR2 CABLE AND BONDING 
BRAID INSTALLATION 
☐ CORRECT 
☐ NOT CORRECT 
☐ CORRECT 
☐ NOT CORRECT 
NOTE:

### Page 14

Remarks:
Information: 
SERVICE BULLETIN COMPLIANCE   FORM Date:
Number:
Revision:
Please send to the following address: 
Telephone:
Fax:
 B.T. Compliance Date:
 Customer Name and Address:
 Helicopter Model S/N Total Number Total Hours T.S.O.
LEONARDO S.p.A.
CUSTOMER SUPPORT & SERVICES - ITALY
PRODUCT SUPPORT ENGINEERING & LICENSES DEPT. 
Via  Giovanni Agusta, 520
21017  Cascina  Costa di Samarate (VA) - ITALY 
Tel.: +39 0331 225036  Fax: +39 0331 225988
We request your cooperation in filling this form,  in order to keep out statistical data relevant to aircraft configuration up-to-date. The form should be filled in all
its parts and sent to the above address or you can communicate the application also via Technical Bulletin Application Communication Section placed in 
Leonardo AW Customer Portal - MyCommunications Area. We thank you beforehand for the information given.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.