### Page 1

XX 
 
 
 
 
 
TRANSLATION OF
  
BOLLETTINO TECNICO 
N°  109S-35 
 
The technical content of this document is approved 
under the authority of DOA nr EASA.21J.005. 
DATE  December 11, 2009 
  
 
 REV.  xxxxxxx 
 
 
Compliance with 
this bollettino is: 
 
 
 
 
 
 
                           XX                         Page 1 of 8 
 
SUBJECT: MODIFICATION OF THE “BATT BUS” CIRCUIT BREAKER 
INSTALLATION. 
 
REASON: Modify the fuselage electrical installation P/N 109-0742- 52 and the 
overhead panel electrical installation P/N 109-0742-55, by means of the 
“BATT BUS” circuit breaker modification kit P/N 109-0824-73-107.  
 
HELICOPTERS AFFECTED: 
All Agusta A109S helicopters up to S/N 22151 included. 
 
COMPLIANCE: 
Within and not later than 50 (fifty) flight hours after the receipt of this 
Bollettino and, however, not later than June 30, 2010. 
 
DESCRIPTION: 
During investigations conducted by Agusta on the electrical power 
generation system of the A109 series helicopter, it has been discovered that 
the 35 Amps “BATT BUS” Circuit Breaker characteristics resulted not within 
design requirements. In the event of a double electrical failure involving, at 
least, one of the generators, “BATT BUS” Circuit Breaker with degraded 
characteristic may result marginal in case of improper use of both landing 
and search lights. 
This Bollettino has been issued with the purpose to provide the necessary 
instructions to apply the “BATT BUS” circuit breaker modification kit P/N 
109-0824-73-107, for the replacement of the 35 Amps circuit breaker with a 
50 Amps circuit breaker and the replacement of the wires with oversized 
ones.  
MANDATORY
An appropriate entry should  be made in the  aircraft log book upon  accomplishment.
If ownership of aircraft has changed, please, forward to new owner .
An Company
Via GiovanniAgusta, 520
21017 Cascina Costa di Samarate (VA) Italy
T el.: +39 0331-229111 - Fax: +39 0331-229605/222595

### Page 2

B.T.109S-35 
 
 
Page 2 of 8 
 
 
REQUIRED MANPOWER: 
An estimated of 8 (eight) manpower hours are required for compliance with 
this Bollettino. 
 
WARRANTY: 
The parts required to apply the present Bollettino shall be supplied on a free 
of charge basis by Agusta upon request, except the consumable materials. 
Upon application of this Bollettino, Customers are requested to submit to 
Agusta Warranty Administration the Technical Bulletin Compliance form 
attached to this Bollettino duly completed in all its parts. 
 
REQUIRED MATERIALS: 
The following materials are required for compliance with this Bollettino: 
 
P/N DENOMINATION Q.TY        
109-0824-73-107 “BATT BUS” circuit breaker 1 
 modification kit  
consisting of: 
A583A2610W Stowage cap .4 
CCH-36-101-0075 Conductive tape .1 roll 
MS25244-50 
or  
30-072-1 50A circuit breaker .1 
or 
700-001-50 
109-0824-73-111 Cable assy .1 
 
In addition the following consumable material is necessary: 
 
SPECIFICATION DENOMINATION  Q.TY  
MIL-T-43435  Lacing cord A.R. 
  (code 900004953) 
 
SPECIAL TOOLS: 
N. A. 
 
WEIGHT AND BALANCE CHANGES:  
Accomplishment of  this Bollettino has the following effect on weight and 
balance: 
 
WEIGHT 
(kg) 
STA 
(mm) 
MOMENT 
(kgmm) 
0.605 3688 2231.2 
 
REFERENCES: 
0B-A-AMP-00-X Maintenance Publication. 
 
PUBLICATIONS AFFECTED: 
0B-A-AWDP-00-X Wiring Data Publication. 
0B-A-IPD-00-X Illustrated Parts Data Publication.

### Page 3

B.T.109S-35 
 
 
Page 3 of 8 
 
 
COMPLIANCE INSTRUCTIONS: 
(See figures 1÷3) 
 
1. Prepare the helicopter on ground for a safe maintenance, disconnect 
any power supply. 
 
2. In accordance with instructions given in the 0B-A-AMP-00-X 
Maintenance Publication, gain access to the baggage compartment , 
open the panel assy D19 and remove the panels P66 and P67. 
 
3. With reference to figure 2 view C -C, on STA 4910.0 bulkhead , 
identify the 35 Amps “BATT BUS” circuit breaker. 
 
4. Electrically disconnect and remove from the bulkhead the 35 Amps 
“BATT BUS” circuit breaker. 
 
5. With reference to figure 3 detail D and figure 1 wiring diagram , 
disconnect and remove the wire marked P140A10 from pin A1 of the 
K7201 battery relay located in the baggage compartment. 
 
NOTE 
As an alternative , it is possible to stow the 
wire provided the installation of two stowage 
caps P/N A583A2610W. 
 
6. With reference to figure 3 detail D and figure 1 wiring diagram, 
connect the wire marked P140A8 to pin A1 of the K7201 battery 
relay. 
 
7. With reference to figure 2 view C-C and figure 1 wiring diagram, to 
the wire marked P140A8 connect the circuit breaker P/N MS25244-
50 or P/N 30 -072-1 or P/N 700 -001-50 (50 Amps) and temporary 
install it on STA 4910.0 bulkhead. 
 
8. In accordance with in structions given in the 0B -A-AMP-00-X 
Maintenance Publication, remove the transmission forward fairing 
P15, the engine air intake D28 and the panel P46B. 
 
9. In accordance with instructions given in the 0B-A-AMP-00-X 
Maintenance Publication , open the overhead  panel and with 
reference to figure 3 detail E, identify the bus-bar of the “DAU CH-A” 
and “EDU 1” circuit breakers. 
 
10. With reference to figure 3 detail E and figure 1 wiring diagram, from 
the bus-bar disconnect the wire marked P140B10. 
 
11. With reference to figure 1, remove the wire marked P140B10.

### Page 4

B.T.109S-35 
 
 
Page 4 of 8 
 
 
NOTE 
As an alternative it is possible to stow the wire 
provided the installation of two stowage caps 
P/N A583A2610W. 
 
12. With reference to figure 1 cable routing and relevant wiring diagram, 
route the wire marked P14 0B8 from the circuit breaker P/N 
MS25244-50 located on STA 4910.0 bulkhead up to the “DAU CH -A” 
and “EDU 1” circuit breakers bus -bar into the overhead panel, 
following the existing harness routing, through the electronic 
compartment, the RH upper beam, and the overhead panel. 
 
13. Connect the part covered with the copper braid ( between the RH 
upper beam outlet and the overhead panel inlet ) of the cable assy 
P/N 109 -0824-73-111, to the others braids installed on the 
helicopters using conductive tape P/N CCH-36-101-0075. 
 
NOTE 
If installed remove and then restore the PVC 
cover. 
 
14. With reference to figure 3 detail E and figure 1 wiring diagram, 
connect the wire marked P140B8 to the “DAU CH-A” and “EDU 1” 
circuit breakers bus-bar using the existing fixing hardware. 
 
15. With reference to figure 2  view C -C, from STA 4910.0 bulkhead 
remove the circuit breaker P/N MS25244-50 and in accordance with 
figure 1 wiring diagram connect the wire marked P140B8. 
 
16. Definitively install the circuit breaker P/N MS25244-50 on STA 
4910.0 bulkhead. 
 
17. Secure the wires marked P140A8 and P140B8 to the existing 
harness using MIL-T-43435 lacing cord. 
 
18. In accordance with instructions given in the 0B-A-AMP-00-X 
Maintenance Publication , close the overhead panel, the panel assy 
D19, reinstall the panels P66 and P67, the engine air intake D28 and 
the panel P46B (restoring the seal). 
 
19. Perform the following checks: 
 
19.1 Connect a suitable external electrical power source in accordance 
with instructions given in the 0B-A-AMP-00-X Maintenance 
Publication. 
 
19.2 Ensure that the GEN BUS 1 and the GEN BUS 2 switches are OFF. 
 
19.3 Position the INV 1 switch ON.

### Page 5

B.T.109S-35 
 
 
Page 5 of 8 
 
 
19.4 Check that the Radio Master switch, on the miscellaneous panel, is 
ON. 
 
19.5 Verify that the following systems are operative: 
 
 LANDING LIGHT 
 EHSI & EADI PLT 
 EDU 1 & EDU 2 
 INVERTER 1 
 LANDING GEAR INDICATOR 
 FUEL PUMP 1 & 2 
 GPS/NAV1 
 
19.6 Disconnect the external electrical power supply in accordance with 
instructions given in the 0B-A-AMP-00-X Maintenance Publication. 
 
19.7 Restore the initial conditions. 
 
20. Return the helicopter to a ready to flight condition. 
 
21. Record the accomplishment of  this Bollettino in the helicopter log 
book.

### Page 6 (OCR)

B.T.109S-35
SEE DETAIL D
(REF.) J8618
COVER WITH COPPER BRAID THE PART
OF WIRE P140B8 BETWEEN THE RIGHT  (REF.) J8617
SIDE UPPER BEAM OUTLET AND THE OVERHEAD
SEE DETAIL E
REMOVE OR STOW THE WIRES
P140A10 AND P140B10 AS SHOWN
ON WIRING DIAGRAM
ADD.:
109-0824-73-111 CABLE ASSY
FOR ROUTING AND FIXING POINTS
FOLLOWS THE EXISTING HARNESS
BATTERY  →--- 03 AU CHA
BUS
P140A8  Õ 500  - P140B8 -
P140A10-  -P140B10- ]
A583A2601W STOWAGE CAP (4 OFF)
109-0824-73-111 CABLE ASSY
FIGURE 1
Page 6 of 8

### Page 7 (OCR)

B.T.109S-35
- 109-0742-52 FUSELAGE ELECTRICAL INSTL (REF.)
REMOVE
BL  MS25244-35 CIRCUIT BREAKER
TREF  ADD:
MS25244-50 CIRCUIT BREAKER
VIEW C-C
(VIEW LOOKING FWD STA 4910.0 BULKHEAD)
FIGURE 2
Page 7 of 8

### Page 8 (OCR)

B.T.109S-35
109-0742-55 OVERHEAD PANEL ELECTRICAL INSTL. (REF)
- "P140B8" WIRE (REF)
ID ID ID!
- "EDU 1" CIRCUIT BREAKER (REF)
- "DAU CH-A" CIRCUIT BREAKER (REF)
DETAIL E
(VIEW LOOKING FWD WITH PANEL OPEN)
5160.0
STA
5410.0
REF
- 109-0742-52 FUSELAGE ELECTRICAL INSTL. (REF)
• K7201 BATTERY RELAY (REF)
DETAIL D
(VIEW LOOKING DOWN)
FIGURE 3
Page 8 of 8

### Page 9

Note: 
Remarks: 
Informazioni: 
Information: 
 
Al fine di gestire le varianti alla configurazione base, in relazione all’emissione del Bollettino Tecnico, preghiamo di voler compilare il presen-
te modulo in tutte le sue parti e spedirlo all’indirizzo sopra indicato. Si ringrazia per la gentile collaborazione data.  
We request your cooperation in filling this form,  in order to  keep out statistical data relevant to aircraft configuration up- to-date. The form should be filled in all 
its parts and sent to the above address. We thank you beforehand for the information given. 
MODULO APPLICAZIONE BOLLETTINO TECNICO 
TECHNICAL BULLETIN COMPLIANCE FORM 
Data: 
Date: 
Numero: 
Number: 
Revisione: 
Revision: 
Prego spedire a questo indirizzo: 
Please send to the following address: 
 
AGUSTA S.p.A. 
CUSTOMER SUPPORT & SERVICES - ITALY
PRODUCT SUPPORT ENGINEERING DPT.
Via del Gregge, 100 
21015 Lonate Pozzolo (VA) - ITALY 
Tel.: +39 0331 711100 
Fax: +39 0331 711180
Telefono: 
Telephone: 
Fax: 
Data Applicazione B.T.: 
B.T. Compliance Date: 
Denominazione Cliente ed Indirizzo: 
Customer Name and Address: 
Modello Elicottero 
Helicopter Model S/N Matricola Tail Number Ore Totali Total Hours Ore D.U.R. T.S.O.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.