# Leonardo Alert Service Bulletin 139-648: Revision A

- Rights: © Leonardo S.p.A. Filed by the FAA in regulations.gov docket FAA-2021-1174; AD 2022-07-01 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Leonardo Alert Service Bulletin 139-648](https://openairdocs.org/service-documents/leonardo/sb-139-648.md)
- Title as filed: Leo  Helicopters ASB 139-648 Rev A
- Pages: 18
- PDF: https://openairdocs.org/files/sha256/d8/97/d897f9b46b8a1f378491b8ac9714cb264b127f4c70cb4f620eca80950eef1d81
- Page: https://openairdocs.org/service-documents/leonardo/sb-139-648/file/d897f9b46b8a

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

N ° 139-648 
D ATE:  August 10, 2020 
REV. :  A  - February 15, 2021 
P age 1 of 17 
TITLE 
ATA 25 – LIFERAFT RESERVOIR INSPECTION AND REPLACEMENT 
REVISION LOG 
The Revision A of this Service Bulletin supersedes the first issue dated August 10, 2020. 
Helicopters that have complied with previous issue of this Service Bulletin do not need any 
additional action. 
Revision A is issued in order to provide further clarifications on the life raft reservoirs S/N 
affected by this SB (refer to the Effectivity section). 
Revision bars identify changes. 
An appropriate entry should be made in the aircraft log book upon accomplishment.
If ownership of aircraft has changed, please, forward to new owner.
Leonardo S.p.A.
Via Giovanni Agusta, 520
21017 Cascina Costa di Samarate (VA) Italy
Tel.: +39 0331 229111 - Fax: +39 0331 229605/222595
ALERT
SERVICE BULLETIN

### Page 2

S.B. N°139-648 ALERT 
 DATE: August 10, 2020 
Page 2 of 17 REVISION: A - February 15, 2021 
1. PLANNING INFORMATION 
A. EFFECTIVITY 
 
NOTE 
LH/RH liferaft reservoirs are NOT affected by Part I of 
this SB if the S/N marked on the external identification 
label (or recorded on the component Log Card) is 
followed by the suffix “ R” (e.g. “VT098855 R” or 
“VI026547R”), even if they have a S/N listed in Table 1 
below.  
All liferaft reservoirs S/N listed in Table 1 and followed 
by the suffix "R" are also affected by Part II and Part III.  
 
Part I: 
LH/RH liferaft reservoirs listed in Table 1, installed on AW139 helicopters or kept in 
stock. 
P/N S/N Description 
3G2560V01251 
VT098855, VT098888, VT106705, VT108649, 
VT113304, VT113311, VT113313, VT113317, 
VT113735, VT114524, VT115880, VT117146, 
VT118688, VT118955, VT119904, VT126158, 
VT143258, VT152697, VT154330, VT162132, 
VT169279 
LH liferaft reservoir 
3G2560V01951 
VI026547, VT037511, VT037569, VT066175, 
VT104133, VT106695, VT108652, VT111164, 
VT113323, VT113325, VT113326, VT113328, 
VT114485, VT118643, VT123350, VT126156, 
VT142275, VT154331, VT157588, VT158618, 
VT158847, VT158848, VT161457 
RH liferaft reservoir 
Table 1 
Part II: 
LH/RH liferaft reservoirs P/N 3G2560V01251/ 3G2560V01951 (part of 15pax/18pax 
emergency flotation kit P/N 4G9560F00111/ 4G9560F00211) with S/N not listed in 
Table 1. 
Part III: 
LH/RH liferaft reservoirs P/N 3G2560V01251/ 3G2560V01951 (part of 15pax/18pax 
emergency flotation kit P/N 4G9560F00111/ 4G9560F00211) with S/N not listed in 
Table 1.

### Page 3

S.B. N°139-648 ALERT 
DATE: August 10, 2020 
REVISION: A - February 15, 2021 Page 3 of 17 
B. COMPLIANCE 
Part I: 
- Within twenty-five (25) FH from the first issue date of this Service Bulletin, for LH/RH 
reservoirs installed on the helicopter at the time of the first issue date of this Service 
Bulletin. 
- Before the next installation on AW139 helicopter but not later than one (1) month, 
from the first issue date of this Service Bulletin, for LH/RH reservoirs kept in stock. 
Part II: 
- Within twenty-five (25) FH from the first issue date of this Service Bulletin or when 
they reach fifty (50) FH since new or since first installation after replacement on a 
helicopter, whichever comes later, for parts installed on the helicopter at the time of 
the first issue date of this Service Bulletin. 
Part III: 
- Within twenty-five (25) from the first issue date of this Service Bulletin, for parts 
installed on the helicopter at the time of the first issue date of this Service Bulletin. 
- Immediately after installation on the helicopter, for LH/RH reservoir installed as 
replacement part. 
C. CONCURRENT REQUIREMENTS 
N.A. 
D. REASON 
This Service Bulletin is issued to prescribe one-off inspections of LH and RH liferaft 
reservoir installation and the replacement of few specific reservoir serial numbers. 
E. DESCRIPTION 
Following an inadvertent life raft deployment event on an in-service AW139 helicopter, 
Leonardo Helicopters Division has precautionary developed this Service Bulletin to 
verify the correct installation of the LH and RH life rafts inflation system. 
Part I of this Service Bulletin prescribes the removal from the helicopter of some life raft 
reservoir S/Ns. 
Moreover, Part II and Part III provide instructions for a one-off inspection of the valve 
pull rod and of the life raft actuator cable, to make sure that they are correctly installed 
on the whole AW139 fleet equipped with 15pax/18pax emergency flotation kit 
P/N 4G9560F00111/ 4G9560F00211. 
In case of findings, the cable rigging and/or the replacement of the life raft reservoir are 
required.

### Page 4

S.B. N°139-648 ALERT 
 DATE: August 10, 2020 
Page 4 of 17 REVISION: A - February 15, 2021 
 
F. APPROVAL 
The technical content of this Service Bulletin is approved under the authority of DOA nr. 
EASA.21.J.005. For helicopters registered under other Aviation Authorities, before 
applying the Service Bulletin, applicable Aviation Authority approval must be checked 
within Leonardo Helicopters customer portal. 
EASA states mandatory compliance with inspections, modifications or technical 
directives and related time of compliance by means of relevant Airworthiness Directives. 
If an aircraft listed in the effectivity embodies a modification or repair not LHD certified 
and affecting the content of this Service Bulletin, it is responsibility of the 
Owner/Operator to obtain a formal approval by Aviation Authority having jurisdiction on 
the aircraft, for any adaptation necessary before incorporation of the present Service 
Bulletin. 
G. MANPOWER 
To comply with this Service Bulletin the following MMH are deemed necessary: 
Part I: approximately one (1) MMH; 
Part II: approximately one (1) MMH; 
Part III: approximately one (1) MMH. 
MMH are based on hands-on time and can change with personnel and facilities 
available. 
H. WEIGHT AND BALANCE 
N.A.  
I. REFERENCES 
1) PUBLICATIONS 
DATA MODULE DESCRIPTION PART 
DM01 39-A-00-20-00-00A-120A-A Helicopter on ground for a safe 
maintenance 
I, II, III 
DM02 39-A-06-41-00-00A-010A-A Access doors and panels - General 
Data 
II, III 
DM03 39-E-25-62-01-00A-520A-K Left bottle assembly - Remove 
procedure 
I, II 
DM04 39-E-25-62-01-00A-720A-K Left bottle assembly - Install 
procedure 
I, II 
DM05 39-E-25-62-02-00A-520A-K Right bottle assembly - Remove 
procedure 
I, II

### Page 5

S.B. N°139-648 ALERT 
DATE: August 10, 2020 
REVISION: A - February 15, 2021 Page 5 of 17 
DATA MODULE DESCRIPTION PART 
DM06 39-E-25-62-02-00A-720A-K Right bottle assembly - Install 
procedure 
I, II 
2) ACRONYMS 
AMDI Aircraft Material Data Information 
AMP Aircraft Maintenance Publication 
DM Data Module 
FH Flight Hours 
FOC Free Of Charge 
ITEP Illustrated Tool and Equipment Publication 
LHD Leonardo Helicopters Division 
MMH Maintenance Man Hours 
RA Return Authorization 
3) ANNEX 
N.A. 
J. PUBLICATIONS AFFECTED 
N.A. 
K. SOFTWARE ACCOMPLISHMENT SUMMARY 
N.A.

### Page 6

S.B. N°139-648 ALERT 
 DATE: August 10, 2020 
Page 6 of 17 REVISION: A - February 15, 2021 
2. MATERIAL INFORMATION 
A. REQUIRED MATERIALS 
1) PARTS 
PART I 
# P/N ALTERNATIVE P/N DESCRIPTION Q.TY LVL NOTE LOG P/N 
1 3G2560V01251  LH liferaft reservoir 1 . (1) (2) (3) - 
2 3G2560V01951  RH liferaft reservoir 1 . (1) (2) (3) - 
2) CONSUMABLES 
Refer to AMDI for the consumable materials required to comply with the AMP DM 
referenced in the accomplishment instructions. 
3) LOGISTIC MATRIX 
N.A. 
NOTE 
(1) Item to be supplied in exchange for one of the S/N listed in Table 1 of 
“EFFECTIVITY” paragraph.  
(2) Refer to “INDUSTRY SUPPORT INFORMATION” paragraph for details to request 
the parts. 
(3) The component documentation may refer to Document No MPP-234 Revision N/C 
(AW139 Liferaft Reservoir Assembly Rework) as an approved procedure for marking 
the reservoir S/N with the suffix “R”. 
B. SPECIAL TOOLS 
# P/N DESCRIPTION Q.TY NOTE PART 
3 601.2382 Diffuser cap REF (B1) II 
Refer also to ITEP for the special tools required to comply with the AMP DM 
referenced in the accomplishment instructions. 
SPECIAL TOOLS NOTE 
 Item to be provided by the supplier along with the serviceable RH/LH liferaft 
reservoir. Refer to “INDUSTRY SUPPORT INFORMATION” paragraph for details.

### Page 7

S.B. N°139-648 ALERT 
DATE: August 10, 2020 
REVISION: A - February 15, 2021 Page 7 of 17 
C. INDUSTRY SUPPORT INFORMATION 
To receive replacement component and tool in support of this Service Bulletin, the 
Customer should e-mail a free of charge purchase order to support@dartaero.com.  
The purchase order should be made to DART Aerospace and make reference to  
Service Bulletin 139-648, with instructions on the location where the replacement has to 
be shipped. DART will issue an RA for the component being replaced and would require 
that the return component be shipped to DART within five (5) business days of receiving 
the replacement. The return address will be indicated on the RA with shipping 
instructions. Shipping costs will be FOC for customers. If the component is not returned, 
there will be a charge for the replacement component that has been shipped.

### Page 8

S.B. N°139-648 ALERT 
 DATE: August 10, 2020 
Page 8 of 17 REVISION: A - February 15, 2021 
3. ACCOMPLISHMENT INSTRUCTIONS 
GENERAL NOTES 
a) Place an identification tag on all components that 
are re-usable, including the attaching hardware that 
has been removed to gain access to the modification 
area and adequately protect them until their later re-
use. 
b) All lengths are in mm. 
PART I 
NOTE 
Steps 1 thru 5 are applicable to LH/RH life raft reservoirs 
installed on the helicopter.  
1. In accordance with AMP DM 39-A-00-20-00-00A-120A- A, prepare the helicopter on 
ground for a safe maintenance. Disconnect the battery, all electrical power sources and/or 
the external power supply. 
2. Remove the affected LH/RH life raft reservoir P/N 3G2560V01251/3G2560V01951 from 
the helicopter, in accordance with the relevant AMP DM: 
 39-E-25-62-01-00A-520A-K - Left bottle assembly - Remove procedure; 
 39-E-25-62-02-00A-520A-K - Right bottle assembly - Remove procedure. 
NOTE 
While applying step 3, do not connect the life-raft 
inflation hose P/N 3G2560L00131 to the bottle 
assembly, as it must be disconnected for the application 
of step 4.  
3. Install a serviceable LH/RH life raft reservoir P /N 3G2560V01251/3G2560V01951 to 
replace the part removed at previous step 2, in accordance with the relevant AMP DM: 
 39-E-25-62-01-00A-720A-K - Left bottle assembly - Install procedure; 
 39-E-25-62-02-00A-720A-K - Right bottle assembly - Install procedure. 
4. Perform the life raft actuator cable inspection in accordance with Part III of this Service 
Bulletin. 
5. Return the helicopter to flight configuration and record for compliance with Part I of this 
Service Bulletin on the helicopter logbook. 
6. Send the affected LH/RH liferaft reservoir to the supplier; for details Refer to “INDUSTRY 
SUPPORT INFORMATION” paragraph.

### Page 9

S.B. N°139-648 ALERT 
DATE: August 10, 2020 
REVISION: A - February 15, 2021 Page 9 of 17 
7. Send the attached compliance form to the following mail box:
 engineering.support.lhd@leonardocompany.com  
As an alternative, gain access to My Communications section on Leonardo WebPortal and 
compile the “Service Bulletin Application Communication”.

### Page 10

S.B. N°139-648 ALERT 
 DATE: August 10, 2020 
Page 10 of 17 REVISION: A - February 15, 2021 
PART II 
1. In accordance with AMP DM 39-A-00-20-00-00A-120A-A, prepare the helicopter on 
ground for a safe maintenance, if required. Disconnect the battery, all electrical power 
sources and/or the external power supply. 
2. In accordance with AMP DM 39-A-06-41-00-00A-010A-A and with reference to Figure 1, 
gain access to the affected area. 
3. With reference to Figure 1 Detail B, disconnect the flex hose P/N 3G2560L00131 from the 
bottle valve. 
4. With reference to Figure 2 Detail A, install the diffuser cap P/N 601.2382. 
5. With reference to Figures 1 and 2, perform the valve pull rod inspection as described in 
the following procedure: 
5.1 With reference to Figure 1 Detail B and Figure 2 Detail B, perform the 
measurement of the actuation cable between the face of the pull rod and the back 
of the valve cap and compare it with the maximum allowed of 68.5 mm (see 
measure A). 
NOTE 
Perform following steps 5.2 thru 5.4 only if the 
measurement value exceeds the allowed limit. 
Otherwise skip to step 6. 
5.2 Remove the affected LH/RH life raft reservoir P/ N 3G2560V01251/3G2560V01951 
from the helicopter, in accordance with the relevant AMP DM: 
 39-E-25-62-01-00A-520A-K - Left bottle assembly - Remove procedure; 
 39-E-25-62-02-00A-520A-K - Right bottle assembly - Remove procedure. 
5.3 Send the affected LH/RH liferaft reservoir to the supplier to adjust/replace the valve 
assy; for details refer to “INDUSTRY SUPPORT INFORMATION” paragraph. 
5.4 Install a serviceable LH/RH life raft reservoir P/N 3G2560V01251/3G2560V01951 
on the helicopter, in accordance with the relevant AMP DM: 
 39-E-25-62-01-00A-720A-K - Left bottle assembly - Install procedure; 
 39-E-25-62-02-00A-720A-K - Right bottle assembly - Install procedure. 
NOTE 
Do not perform steps 6 and 7 at this time if it is required 
to perform also the life raft actuator cable inspection, in 
accordance with Part III. 
6. With reference to Figure 2 Detail A remove the di ffuser cap P/N 601.2382 from the bottle 
valve. 
7. With reference to Figure 1 Detail B, connect the flex hose P/N 3G2560L00131 to the bottle

### Page 11

S.B. N°139-648 ALERT 
DATE: August 10, 2020 
REVISION: A - February 15, 2021 Page 11 of 17 
valve. Tighten the nut of the hose to the standard torque value. 
8. Repeat steps 2 thru 7 for the other side, if required. 
9. Return the helicopter to flight configuration, if required, and record for compliance with 
Part II of this Service Bulletin on the helicopter logbook. 
10. Send the attached compliance form to the following mail box:
 engineering.support.lhd@leonardocompany.com  
As an alternative, gain access to My Communications section on Leonardo WebPortal and 
compile the “Service Bulletin Application Communication”.

### Page 12

S.B. N°139-648 ALERT 
 DATE: August 10, 2020 
Page 12 of 17 REVISION: A - February 15, 2021 
PART III 
NOTE 
Steps 1 and 2 are not applicable if Part III is performed 
at the same time of Part II. 
1. In accordance with AMP DM 39-A-00-20-00-00A-120A- A, prepare the helicopter on 
ground for a safe maintenance, if required. Disconnect the battery, all electrical power 
sources and/or the external power supply. 
2. In accordance with AMP DM 39-A-06-41-00-00A-010A-A and with reference to Figure 1, 
gain access to the affected area. 
NOTE 
Following steps 3 and 4 are not applicable if the 
inspection is performed on a newly installed liferaft 
reservoir or the diffuser cap has been already installed, 
complying with Part II. 
3. With reference to Figure 1 Detail B, disconnect t he flex hose P/N 3G2560L00131 from the 
bottle valve. 
4. With reference to Figure 2 Detail A, install the diffuser cap P/N 601.2382. 
5. With reference to Figure 1, perform the life raft actuator cable inspection as described in 
the following procedure: 
5.1 With reference to Figure 1 View A and Detail C, with the junction box actuation arm 
in its rest position (90° with respect to the helicopter longitudinal axis), verify the 
presence of a 5.0.. mm clearance between the sphere at the end of the cable 
and the activation system in accordance with the measurement range shown (see 
measure B).  
5.2 If the measurement value exceeds the allowed limit, perform the life raft activation 
cable adjustment in accordance with Annex A. 
6. With reference to Figure 2 Detail A, remove the diffuser cap P/N 601.2382 from the valve. 
7. With reference to Figure 1 Detail B, connect the flex hose P/N 3G2560L00131 to the bottle 
valve. Tighten the nut of the hose to the standard torque value. 
8. Repeat steps 2 thru 7 for the other side, if required. 
9. Return the helicopter to flight configuration, and record for compliance with Part III of this 
Service Bulletin on the helicopter logbook. 
10. Send the attached compliance form to the following mail box:
 engineering.support.lhd@leonardocompany.com  
As an alternative, gain access to My Communications section on Leonardo WebPortal and 
compile the “Service Bulletin Application Communication”. mai questo segnalibro

### Page 13 (OCR)

: LEONARDO
HELICOPTERS
MLG AFT FAIRING ASSY  (REF)  MLG LEFT PANEL  (REF)  STRUCTURE AND SYSTEMS ARE PARTIALLY OTTED FOR BETTER CLARITY PURPOSE
LIFERAFT ACTUATOR CABLE INSPECTION  DETAIL E
3G2560V01451 JUNCTION BOX (REF)  JUNCTION BOX ACTUATION ARM  3620VAFF RESERVOIR (SHOWN)  3G2560V01951 (RH OPPOSITE)  PH TIFFRAET RESERVOIR (OPPOSITE  (REF)  VIEW A
MS24665-151 PIN (REF)  INFLATION SYSTEM  ACTIVATION CABLE (REF)  LOCK NUT SWIVEL (REF)  NAS509-6C NUT (REF)  MS20995C41 LOCK WIRE  REF  PILOT HANDLE AND CABLE ASSY  (REF)  BACK-UP HANDLE AND CABLE ASSY  (REF)
CABLE ROD (REF)  SHROUD (REF)  INFLATION SYSTEM  ACTIVATION CABLE (REF  LOCK NUT SWIVEL (REF)  NAS509-6C NUT (REF)  MS20995C41 LOCK WIRE
DETAIL B  LH SHOWN (TYP OPPOSITE SIDE)  12.5  (REF)  LH SHOWN (TYP OPPOSITE SIDE)
MEASURE A  DETAIL C
FLARED FITTING (REF)  3G2560L00131 FLEX HOSE  (REF)  VALVE ASSY (REF)  5.0 :  MEASURE B
Figure 1
S.B. N°139-648
DATE: August 10, 2020
REVISION: A - February 15, 2021  Page 13 of 17

### Page 14 (OCR)

LEONARDO
HELICOPTERS
Diffuser cap P/N 601.2382
DETAIL A
(0000 PSI)  USAI
oF  ELIN  80
WOIRS
DETAIL B
Figure 2
S.B. N°139-648
DATE: August 10, 2020
Page 14 of 17  REVISION: A - February 15, 2021

### Page 15

S.B. N°139-648 
DATE: August 10, 2020 
REVISION: A - February 15, 2021 Page 15 of 17 
ANNEX A 
LIFERAFT ACTIVATION CABLE ADJUSTMENT

### Page 16

S.B. N°139-648 
 DATE: August 10, 2020 
Page 16 of 17 REVISION: A - February 15, 2021 
In order to obtain a clearance of 5 mm +0/-2 between the spherical end of the cable and the 
Pull Rod adjust the cable length acting on the lock nuts at the end of the activation cable zone 
(Figure A1). 
If this first adjustment reveals to be not sufficient, act also on the locking nuts in the Junction 
Box zone (Figure A2) and then make small corrections acting on the locking nuts at the end 
of the activation cable. 
1 END OF ACTIVATION CABLE ZONE LOCK NUTS 
1.1 Unscrew the 9/16” tightening nut. 
1.2 Adjust the cable length acting on the 5/8” regulation nut. 
 TO INCREASE THE GAP: unscrew the regulation nut; 
 TO DECREASE THE GAP: screw the regulation nut. 
1.3 Screw the 9/16” tightening nut in order to block the regulation nut. 
 
 
Figure A1 – Activation cable zone

### Page 17

S.B. N°139-648 
DATE: August 10, 2020 
REVISION: A - February 15, 2021 Page 17 of 17 
2 JUNCTION BOX ZONE LOCK NUTS 
Both lock nuts are 9/16”. 
 
2.1 Remove safety-wire from the nuts. 
2.2 Adjust the gap as follows: 
 TO INCREASE THE GAP: 
o Unscrew External Nut; 
o Screw Internal Nut. 
 TO DECREASE THE GAP: 
o Unscrew Internal Nut; 
o Screw External Nut. 
2.3 Once the correct gap is achieved, make sure that both the internal and the external 
nuts are in contact with the structure and tightened at the standard torque value. 
2.4 Safety the external nut and the internal nut with stainless steel (302/304) medium 
strong safety wire. 
 
 
Figure A2 – Junction box zone 
 
Internal Nut 
External Nut

### Page 18

Remarks:
Information: 
SERVICE BULLETIN COMPLIANCE   FORM Date:
Number:
Revision:
Please send to the following address: 
Telephone:
Fax:
 B.T. Compliance Date:
 Customer Name and Address:
 Helicopter Model S/N Total Number Total Hours T.S.O.
LEONARDO S.p.A.
CUSTOMER SUPPORT & SERVICES - ITALY
PRODUCT SUPPORT ENGINEERING & LICENSES DEPT. 
Via  Giovanni Agusta, 520
21017  Cascina  Costa di Samarate (VA) - ITALY 
Tel.: +39 0331 225036  Fax: +39 0331 225988
We request your cooperation in filling this form,  in order to keep out statistical data relevant to aircraft configuration up-to-date. The form should be filled in all
its parts and sent to the above address or you can communicate the application also via Technical Bulletin Application Communication Section placed in 
Leonardo AW Customer Portal - MyCommunications Area. We thank you beforehand for the information given.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.
