# Leonardo Alert Service Bulletin 189-295: No revision named

- Rights: © Leonardo S.p.A. Filed by the FAA in regulations.gov docket FAA-2024-0236, the docket of AD 2024-10-08. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Leonardo Alert Service Bulletin 189-295](https://openairdocs.org/service-documents/leonardo/sb-189-295.md)
- Title as filed: Leonardo Helicopters ASB No. 189-295
- Pages: 22
- PDF: https://openairdocs.org/files/sha256/5a/3f/5a3f437d10ba5c4ec03e04e1cbc63af8ba5f145ac941fe31e9badc9c33379acb
- Page: https://openairdocs.org/service-documents/leonardo/sb-189-295/file/5a3f437d10ba

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

ERRATA CORRIGE 
 
 
Please find here attached the page that has to be replaced in the basic Service Bulletin 
n°189-295 Rev. /.  
 
 PAGE 14 “Figure 3” 
 
The description of the bottom picture “VIEW D – INC ORRECT ASSEMBLY PRACTICE” has 
been changed. 
 
Was:  
“GLIDE SLOPE ANTENNA P/N 6208-88-62, ANTENNA CORREC TLY MOUNTED, 
PRESENCE OF SEALANT IS NOT FOUND” 
 
Becomes:   
“GLIDE SLOPE ANTENNA P/N 6208-88-62, ANTENNA INCORR ECTLY MOUNTED, 
PRESENCE OF SEALANT IS FOUND”

### Page 2

Pa ge 1 of 20 
N°  189-295 
DA TE:  November 29, 2021 
REV. :  / - March 15, 2017 
TITLE 
ATA 34 – GLIDE SLOPE ANTENNA INSPECTION 
REVISION LOG 
First Issue 
An appropriate entry should be made in the aircraft log book upon accomplishment.
If ownership of aircraft has changed, please, forward to new owner.
Leonardo S.p.A.
Via Giovanni Agusta, 520
21017 Cascina Costa di Samarate (VA) Italy
Tel.: +39 0331 229111 - Fax: +39 0331 229605/222595
ALERT
SERVICE BULLETIN

### Page 3

S.B. N°189-295 ALERT 
 DATE: November 29, 2021 
Page 2 of 20 REVISION: / 
1. PLANNING INFORMATION 
A. EFFECTIVITY 
Part I 
 All AW189 helicopters from S/N 92001 to S/N 92010 equipped with Glide Slope 
Antenna P/N 6208-88-62 as part of the Kit Glide Slope Antenna P/N 
8G3430F00111. 
 All Glide Slope Antennas P/N 6208-88-62, previously installed on the helicopter, 
kept in stock. 
Part II 
All AW189 helicopters from S/N 92001 to S/N 92010 equipped with Glide Slope Antenna 
P/N 6208-88-62 for which the acceptance test procedure prescribed in Part I succeeded, 
but evidence of sealant was still found after the cleaning procedure. 
B. COMPLIANCE 
Part I 
 Within 200 FH or 6 months, whichever occurs first after the issue of this Service 
Bulletin. 
 Before next installation on any helicopter, or within 6 months, whichever occurs 
first after the issue of this Service Bulletin, for any Glide Slope Antenna P/N 
6208-88-62 previously installed on any helicopter and kept in stock. 
Part II 
After 1 year from compliance with Part I. 
C. CONCURRENT REQUIREMENTS 
N.A. 
D. REASON 
This Service Bulletin is issued in order to prescribe a visual inspection of the Glide Slope 
Antenna P/N 6208-88-62, part of the kit Glide Slope Antenna P/N 8G3430F00111, a 
corrective action in case the presence of sealant is found and its replacement if the 
antenna is not operational after the corrective action implementation. 
E. DESCRIPTION 
During the troubleshooting after an unexpected helicopter behavior, the replacement of 
the Glide Slope Antenna solved the malfunction.

### Page 4

S.B. N°189-295 ALERT 
DATE: November 29, 2021 
REVISION: / Page 3 of 20 
A deeper investigation performed by the antenna supplier concluded that the root cause 
of the event were the two coaxial connectors isolated from their ground plane by the 
presence of grey mastic. 
The design, production and maintenance drawing and instructions did not request any 
sealant application in this location. As a consequence, LHD decided to issue this SB to 
check if any other glide slope antenna has a similar sealant application around the 
connectors. 
Part I of this Service Bulletin prescribes the necessary instruction on how to perform the 
visual inspection to check presence of sealant around the Glide Slope Antenna P/N 
6208-88-62. In case of presence of sealant, this SB gives instructions on how to remove 
the sealant from affected areas, and perform an acceptance test procedure. In case of 
failure of the acceptance test, this SB gives the instruction of the replacement of the 
Glide Slope Antenna P/N 6208-88-62 and the n° 2 connectors P/N PE4958 that have 
been found not operational. 
Part II of this Service Bulletin prescribes instructions for the replacement of the Glide 
Slope Antenna P/N 6208-88-62 and/or the connectors P/N PE4958 that have been 
found with persistent presence of sealant after Part I, even in case the antenna passed 
the applicable functional test after cleaning.  
F. APPROVAL 
The technical content of this Service Bulletin is approved under the authority of DOA nr. 
EASA.21.J.005. For helicopters registered under other Aviation Authorities, before 
applying the Service Bulletin, applicable Aviation Authority approval must be checked 
within Leonardo Helicopters customer portal. 
EASA states mandatory compliance with inspections, modifications or technical 
directives and related time of compliance by means of relevant Airworthiness Directives. 
If an aircraft listed in the effectivity embodies a modification or repair not LHD certified 
and affecting the content of this Service Bulletin, it is responsibility of the 
Owner/Operator to obtain a formal approval by Aviation Authority having jurisdiction on 
the aircraft, for any adaptation necessary before incorporation of the present Service 
Bulletin. 
G. MANPOWER 
To comply with this Service Bulletin, the following MMH are deemed necessary. 
Part I: approximately five (5) MMH; 
Part II: approximately three (3) MMH;

### Page 5

S.B. N°189-295 ALERT 
 DATE: November 29, 2021 
Page 4 of 20 REVISION: / 
MMH are based on hands-on time and can change with p ersonnel and facilities 
available. 
H. WEIGHT AND BALANCE 
N.A. 
I. REFERENCES 
1) PUBLICATIONS 
Following Data Modules refer to AMP: 
DATA MODULE DESCRIPTION PART 
DM01 89-A-00-20-00-00A-120A-A Helicopter on ground for a safe 
maintenance. 
I, II 
DM02 89-A-06-41-00-00A-010A-A Access doors and panels –  
General data 
I, II 
DM03 89-A-34-32-01-00A-520A-A Glide slope antenna – Remove 
procedure 
I, II 
DM04 89-A-34-32-01-00A-720A-A Glide slope antenna – Install 
procedure 
I, II 
DM05 89-A-11-00-01-00A-720A-A Decal – Install procedure I, II 
2) ACRONYMS & ABBREVIATIONS 
AMP Aircraft Maintenance Publication 
DM Data Module 
DOA Design Organization Approval 
EASA European Aviation Safety Agency 
FH Flight Hours 
ITEP Illustrated Tool and Equipment Publication 
LHD Leonardo Helicopters Division 
MMH Maintenance Man Hours 
P/N Part Number 
SB Service Bulletin 
S/N Serial Number 
3) ANNEX 
Annex A AW189 External Glide Slope Antenna Kit Acceptance Test Procedure 
Annex B SB Application Form – Inspection report

### Page 6

S.B. N°189-295 ALERT 
DATE: November 29, 2021 
REVISION: / Page 5 of 20 
J. PUBLICATIONS AFFECTED 
N.A. 
K. SOFTWARE ACCOMPLISHMENT SUMMARY 
N.A.

### Page 7

S.B. N°189-295 ALERT 
 DATE: November 29, 2021 
Page 6 of 20 REVISION: / 
2. MATERIAL INFORMATION 
A. REQUIRED MATERIALS 
1) PARTS 
# P/N ALTERNATIVE P/N DESCRIPTION Q.TY LVL NOTE LOG P/N 
1 8G3430F00111  KIT GLIDE SLOPE ANTENNA REF . - - 
2 8G3430A00311  
GLIDE SLOPE 
EQUIPMENT 
INSTALLATION 
REF .. - - 
3 6208-88-62  Glide Slope Antenna 1  … (1)(2) - 
4 ED300E7  Decal 1 … (1)(2) - 
5 MS24693-C278  Screw 6 … (1)(2) - 
6 PE4958  Coaxial Connector AR  .. (1)(2) - 
 
2) CONSUMABLES 
The following consumable materials, or equivalent, are necessary to accomplish this 
Service Bulletin: 
# SPEC./LHD CODE NUMBER DESCRIPTION Q.TY NOTE PART 
7 TT-I-735, Grade A Isopropyl alcohol (C039) AR (3) I 
8 Commercial Soft lint-free cloth (C011) AR (3) I  
 
Refer also to AMDI for the consumable materials required to comply with the AMP DM 
referenced in the accomplishment instructions. 
3) LOGISTIC MATRIX 
N.A. 
NOTE 
(1) Refer to “Industry Support Information” section before ordering this item. 
(2) Item to be ordered only if acceptance test procedure fails or presence of sealant is 
still found after cleaning procedure in Part I. 
(3) Item to be procured as local supply. 
B. SPECIAL TOOLS 
The following special tool, or equivalent, is necessary to accomplish this Service 
Bulletin, in case the visual inspection identifies presence of sealant: 
# P/N DESCRIPTION Q.TY NOTE PART 
9 - Plastic scraper 1 - I 
 
Refer also to ITEP for the special tools required to comply with the AMP DM referenced 
in the accomplishment instructions.

### Page 8

S.B. N°189-295 ALERT 
DATE: November 29, 2021 
REVISION: / Page 7 of 20 
C. INDUSTRY SUPPORT INFORMATION 
Owners/Operators who comply with the instructions of this Service Bulletin no later than 
the applicable date in the “Compliance” section will be eligible to receive “Required 
Materials” on free of charge basis. 
Consumables, Special Tools, and materials required by AMP DM recalled in this SB are 
not included in the aforementioned policy. 
NOTE: Customers who fail to comply with the instructions in this Service Bulletin before 
the compliance date are not eligible for the aforementioned special policy. 
Please Issue relevant MMIR form to your Warranty Administration Dpt. 
NOTE: Filling the form in ANNEX B with the evidence of incorrect assembly practice is 
mandatory; in case the MMIR is not accompanied by this document, it will be rejected.

### Page 9

S.B. N°189-295 ALERT 
 DATE: November 29, 2021 
Page 8 of 20 REVISION: / 
3. ACCOMPLISHMENT INSTRUCTIONS 
GENERAL NOTES 
a) Place an identification tag on all components that 
are re-usable, including the attaching hardware that 
has been removed to gain access to the modification 
area and adequately protect them until their later re-
use. 
b) Shape the cables in order to prevent interference 
with the structure and the other existing installations, 
using where necessary suitable lacing cords and 
plastic cable tiedown.  
PART I 
NOTE 
Skip steps 1 thru 4 for Glide Slope Antennas  
P/N 6208-88-62 kept in stock. 
1. In accordance with AMP DM 89-A-00-20-00-00A-120A- A, prepare the helicopter on 
ground for a safe maintenance. Disconnect the battery, all electrical power sources and/or 
the external power supply. 
2. In accordance with AMP DM 89-A-06-41-00-00A-010A-A and with reference to Figure 1, 
gain access to the Glide Slope Antenna P/N 6208-88-62. 
3. In accordance with AMP DM 89-A-34-32-01-00A-520A-A and with reference to Figure 1 
Detail A, remove the Glide Slope Antenna P/N 6208-88-62. Keep the hardware for later 
reuse. 
4. With reference to Figures 1 thru 3, perform a visual inspection looking for any evidence of 
sealant on the following components: 
 n°2 coaxial connectors P/N PE4958 
 Antenna Support Assy P/N 8G5315A30231. 
5. With reference to Figures 1 thru 3, perform a visual inspection looking for any evidence of 
sealant around the connectors of the Glide Slope Antenna P/N 6208-88-62. 
6. Record the inspection outcome on the report in ANNEX B and continue the procedure 
according to the following instructions: 
6.1 If presence of sealant is not found:

### Page 10

S.B. N°189-295 ALERT 
DATE: November 29, 2021 
REVISION: / Page 9 of 20 
6.1.1 For Glide Slope Antennas P/N 6208-88-62 that were installed on the 
helicopter at the beginning of the accomplishment instructions go to step 
7. 
6.1.2 For Glide Slope Antennas P/N 6208-88-62 kept in stock go to step 13. 
6.2 If presence of sealant is found, with reference to ANNEX B, record the presence 
of sealant in the SB application form and proceed with the following steps. 
CAUTION 
Pay particular attention not to damage any components 
during the sealant removal. 
CAUTION 
Pay attention not to remove the paint from the 
aluminium antenna support during the sealant removal. 
6.3 With reference to Figures 1 thru 3, carefully re move the sealant on all affected 
components by means of a plastic scraper and a lint-free cloth (C011) moistened 
with isopropyl alcohol (C039). 
6.4 After the sealant removal, check that the connector platting is not damaged and 
that no residue remains inside the RF connectors.  
NOTE 
If step 6.5.2 applies, the helicopter has to comply with 
Part II of this SB. Check the COMPLIANCE section for 
the applicable scheduling. 
6.5 With reference to Figures 1 thru 3, perform agai n the inspection on n°2 coaxial 
connectors P/N PE4958 and on the Glide Slope Antenna  
P/N 6208-88-62. 
6.5.1 If presence of sealant is not found after cleaning, go to step 7. 
6.5.2 If presence of sealant is still found, either on the antenna or on the 
coaxial connector(s), even after cleaning, record the persistent presence 
of sealant in the report in ANNEX B. 
7. In accordance with AMP DM 89-A-34-32-01-00A-720A-A and with reference to Figure 1 
Detail A, install the Glide Slope Antenna P/N 6208-88-62 by means of existing hardware. 
8. In accordance with ANNEX A, perform the External Glide Slope Antenna kit acceptance 
test procedure and record the test outcome in the report in ANNEX B. 
8.1 If the External Glide Slope Antenna kit acceptance test procedure succeeds, go to 
step 12. 
8.2 If the External Glide Slope Antenna kit acceptance test procedure fails replace both 
the Glide Slope Antenna P/N 6208-88-62 and n° 2 coaxial connectors P/N PE4958

### Page 11

S.B. N°189-295 ALERT 
 DATE: November 29, 2021 
Page 10 of 20 REVISION: / 
according to the following steps. 
9
. In accordance with AMP DM 89-A-34-32-01-00A-520A-A and with reference to Figure 1 
Detail A, remove the Glide Slope Antenna P/N 6208-88-62, and discard the existing 
hardware. 
10. With reference to Figures 1 and 2, replace the Glide Slope Antenna P/N 6208-88-62 and 
n°2 coaxial connectors P/N PE4958 as follows: 
10.1 In accordance with AMP DM 89-A-34-32-01-00A-720A-A and with reference to 
Figure 1 Detail A, install the new Glide Slope Antenna P/N 6208-88-62 by means 
of n°6 screws P/N MS24693-C278. 
10.2 In accordance with AMP DM 89-A-11-00-01-00A-720A-A and with reference to 
Figure 1 Detail A, install the decal P/N ED300E7. 
10.3 With reference to Figure 1 replace the n°2 coaxial connectors P/N PE4958. 
11. In accordance with ANNEX A, perform the External Glide Slope Antenna kit acceptance 
test procedure. 
12. Return the helicopter to flight configuration and record for compliance with Part I of this 
Service Bulletin on the helicopter logbook. 
13. Send the attached compliance form, report in ANNEX B and pictures to the following mail 
box: 
 engineering.support.lhd@leonardocompany.com 
As an alternative to filling the compliance form, gain access to My Communications section 
on Leonardo WebPortal and compile the “Service Bulletin Application Communication”.

### Page 12

S.B. N°189-295 ALERT 
DATE: November 29, 2021 
REVISION: / Page 11 of 20 
PART II 
1. In accordance with AMP DM 89-A-00-20-00-00A-120A-A, prepare the helicopter on ground 
for a safe maintenance. Disconnect the battery, all electrical power sources and/or the external 
power supply. 
2. In accordance with AMP DM 89-A-34-32-01-00A-520A-A and with reference to Figure 1 
Detail A, remove the Glide Slope Antenna P/N 6208-88-62, and discard the existing 
hardware. 
3. With reference to Figures 1 and 2, replace the Glide Slope Antenna P/N 6208-88-62 and/or 
coaxial connector P/N PE4958 as follows: 
3.1 In accordance with AMP DM 89-A-34-32-01-00A-720A-A and with reference to 
Figure 1 Detail A, install the new Glide Slope Antenna P/N 6208-88-62 by means 
of n°6 screws P/N MS24693-C278. 
3.2 In accordance with AMP DM 89-A-11-00-01-00A-720A-A and with reference to 
Figure 1 Detail A, install the decal P/N ED300E7. 
3.3 With reference to Figure 1 replace the coaxial connector P/N PE4958. 
4. In accordance with ANNEX A, perform the External Glide Slope Antenna kit acceptance 
test procedure. 
5. Return the helicopter to flight configuration and record for compliance with Part II of this 
Service Bulletin on the helicopter logbook. 
6. Send the attached compliance form and report in ANNEX B to the following mail box: 
 engineering.support.lhd@leonardocompany.com 
As an alternative to filling the compliance form, gain access to My Communications section 
on Leonardo WebPortal and compile the “Service Bulletin Application Communication”. 
 
  Non cancellare mai questo segnalibro Non cancellare mai interruzione sezione 

### Page 13 (OCR)

· LEONARDO  HELICOPTERS
DETAIL A
NOSE AND COCKPIT  LH SIDE ISOVIEW  FWD,
_ RH
FAIRING (REF)
6208-88-62 GLIDE SLOPE ANTENNA (REF)
MS24693-C  278 SCREW (6 OFF) (REF)
(REPLACE IF NECESSARY)
G5315A3023  B
NTENNA SUPPORT ASSY (REF  (SEE FIGURE 2)
INSTALL (IF NECESSARY):
ED300E7 DECAL
PE4958 CONNECTOR (REF)
C
(SEE FIGURE 2)  DETAIL A
STRUCTURE AND SYSTEMS ARE PARTIALLY OMITTED FOR BETTER CLARITY PURPOSE
Figure 1
S.B. N°189-295 ALERT
DATE: November 29, 2021
Page 12 of 20  REVISION: /

### Page 14 (OCR)

( LEONARDO  HELICOPTERS
1 FWD
VIEW C  STRUCTURE AND SYSTEMS ARE PEFER TO FIGURE 1 FOR BETTER CLARITY PURPOSE
6208-88-62 GLIDE SLOPE ANTENNA (REF)  (SEE FIGURE 3)
VIEW B  STRUCTURE AND SYSTEMS ARE PEFER TO FIGURE 1 FOR BETTER CLARITY PURPOSE
PERFORM VISUAL INSPECTION  PE4958 CONNECTOR (REF)  (REPLACE IF NECESSARY)
Figure 2
S.B. N°189-295 ALERT
DATE: November 29, 2021
REVISION: /  Page 13 of 20

### Page 15

Figure 3 
 S.B. N°189-295 ALERT 
 DATE: November 29, 2021 
Page 14 of 20 REVISION: / 
CORRECT ASSEMBLY PRACTICE
GLIDE SLOPE ANTENNA P/N 6208-88-62. ANTENNA CORRECTLY MOUNTED, PRESENCE OF SEALANT IS NOT FOUND.
PERFORM VISUAL INSPECTION
USE:
PLASTIC SCRAPER
APPLY:
LINT-FREE CLOTH (C011)
ISOPROPYL ALCOHOL (C039)
PERFORM VISUAL INSPECTION
THE PICTURES ARE FOR REFERENCE PURPOSE ONLY
VIEW D
(REFER TO FIGURE ) 2
INCORRECT ASSEMBLY PRACTICE
GLIDE SLOPE ANTENNA P/N 6208-88-62. ANTENNA INCORRECTLY MOUNTED, PRESENCE OF SEALANT IS FOUND.
VIEW D
(REFER TO FIGURE ) 2

### Page 16

S.B. N°189-295 ALERT 
DATE: November 29, 2021 
REVISION: / Page 15 of 20 
 
ANNEX A 
AW189 EXTERNAL GLIDE SLOPE ANTENNA KIT 
ACCEPTANCE TEST PROCEDURE

### Page 17

S.B. N°189-295 ALERT 
 DATE: November 29, 2021 
Page 16 of 20 REVISION: / 
TEST EQUIPMENT 
 Radio Communication Tester, IFR-4000 or equivalent. 
 
NOTES  
 WHEN TESTING MRC1-GS1, VERIFY THE PROPER GS INDICATION ON COPILOT 
PFD. The NAV1/ILS option shall be selected from the standby instrument display menu 
to activate the GS visualization. 
 WHEN TESTING MRC2-GS2, VERIFY THE PROPER GS INDICATION ON PILOT. 
The NAV2/ILS option shall be selected from the standby instrument display menu to 
activate the GS visualization.  
 
TEST PROCEDURE 
1. Place the ramp test set IFR-4000 close to the cabin: 
 Connect the telescoping antenna to the test set ANT Port; 
 Turn ON the ramp test set; 
 Select the GLIDESLOPE operational mode with the MODE Select Key; 
 Set the RF LVL to –15 dBm; 
 Set the 90/150 Hz to “---“; 
 Set GS DDM to Zero (Center); 
2. Tune the NAV1 frequency to 108.10 MHz by mean the MCDU (or the same set up on the 
LOC FREQ of the Test Set). Select NAV1 source on both PFDs by mean the Display 
Controllers. Make sure that the frequency of 334.70 MHz is showed on the FREQ of the test 
set. 
3. Verify the GS1 indication is correctly displayed (0 DOT of deviation) on both pilot and copilot 
PFDs (Failure flags out of view) and on the standby instrument display. 
4. Set the GS DDM knob to the values listed in Table 1. Verify and note the results.

### Page 18

S.B. N°189-295 ALERT 
DATE: November 29, 2021 
REVISION: / Page 17 of 20 
Table 1 GS1 Marker Deflection Simulation Values 
GS1 Marker Deflection 
KNOB POSITION 
PFD / STBY ADI  
Displayed 
Expected PASS/FAIL 
0.091 DDM UP  
52% UP 
(GS Marker displayed closely 
above the DOT 1) 
 
0.175 DDM UP  
100 % UP 
(2 dots UP) 
 
0.400 DDM UP  RANGE END  
0.091 DDM DOWN  
52% DOWN 
(GS Marker displayed closely 
below the DOT 1) 
 
0.175 DDM DOWN  
100 % DOWN 
2 dots DOWN 
 
0.400 DDM DOWN  RANGE END  
 
GS1 Sensibility 
Ramp Tester Attenuation Limit Value PASS/FAIL 
Attenuation: _______________________ dBm  -25dBm  
 
5. Slowly increase the attenuation of the RF LVL on the ramp test set (more negative dBm). 
Verify that the GS1 visualization is valid (no failure flags) at least until the set attenuation is 
equal to -25 dBm (note result in Table 1). 
6. Set the RF LVL attenuation on the test set back to –15 dBm.  Repeat the tests above (from 
point 1 to 5) for GS2 system and check the correct value on both PFDs and on standby 
instrument display. Note the results in the Table 2. 
7. Set the test set to OFF.

### Page 19

S.B. N°189-295 ALERT 
 DATE: November 29, 2021 
Page 18 of 20 REVISION: / 
Table 2 GS2 Marker Deflection Simulation Values 
GS2 Marker Deflection 
KNOB POSITION 
PFD / STBY ADI  
Displayed 
Expected PASS/FAIL 
0.091 DDM UP 
 52% UP 
(GS Marker displayed closely 
above the DOT 1) 
 
0.175 DDM UP 
 100 % UP 
(2 dots UP) 
 
0.400 DDM UP  RANGE END  
0.091 DDM DOWN 
 52% DOWN 
(GS Marker displayed closely 
below the DOT 1) 
 
0.175 DDM DOWN 
 100 % DOWN 
2 dots DOWN 
 
0.400 DDM DOWN  RANGE END  
 
GS2 Sensibility 
Ramp Tester Attenuation Limit Value PASS/FAIL 
Attenuation: _______________________ dBm  -25dBm

### Page 20

S.B. N°189-295 ALERT 
DATE: November 29, 2021 
REVISION: / Page 19 of 20 
 
ANNEX B 
SB APPLICATION FORM – INSPECTION REPORT

### Page 21

S.B. N°189-295 ALERT 
 DATE: November 29, 2021 
Page 20 of 20 REVISION: / 
Inspection Report - SB 189-295 
Helicopter S/N (if not applicable, write “in stock”)  
Part I Compliance Date   
FH   
1. Specify whether the inspection prescribed in Part I identified the presence of sealant 
in the assembly:  
☐ Sealant was found during the visual 
inspection prescribed in Part I.  
☐ Sealant was not found during the visual 
inspection prescribed in Part I.  
2. If evidence of sealant was found during the inspection, specify the components 
affected by the finding: 
☐ Glide Slope Antenna P/N 6208-88-62 
☐ Connector(s) P/N PE4958 
☐ Antenna Support Assy P/N 8G5315A30231 
Please, also attach picture(s) of the item(s) affected by the presence of sealant. 
3. If evidence of sealant was found, specify whether the sealant has been completely 
removed through the cleaning procedure:  
☐ Sealant was successfully removed.  ☐ Sealant was not successfully removed.  
4. If cleaning was not fully successful, specify the components presenting persistent 
presence of sealant: 
☐ Glide Slope Antenna P/N 6208-88-62 
☐ Connector(s) P/N PE4958 
Please, also attach picture(s) of the item(s) affected by the persistent presence of sealant. 
5. Specify whether the functional test prescribed in Part I has been successful: 
☐ Acceptance test procedure was 
successful.  
☐ Acceptance test procedure was not 
successful.  
The following section should be compiled only if Compliance with Part II is required. 
Part II Compliance Date

### Page 22

Remarks:
Information: 
SERVICE BULLETIN COMPLIANCE   FORM Date:
Number:
Revision:
Please send to the following address: 
Telephone:
Fax:
 B.T. Compliance Date:
 Customer Name and Address:
 Helicopter Model S/N Total Number Total Hours T.S.O.
LEONARDO S.p.A.
CUSTOMER SUPPORT & SERVICES - ITALY
PRODUCT SUPPORT ENGINEERING & LICENSES DEPT. 
Via  Giovanni Agusta, 520
21017  Cascina  Costa di Samarate (VA) - ITALY 
Tel.: +39 0331 225036  Fax: +39 0331 225988
We request your cooperation in filling this form,  in order to keep out statistical data relevant to aircraft configuration up-to-date. The form should be filled in all
its parts and sent to the above address or you can communicate the application also via Technical Bulletin Application Communication Section placed in 
Leonardo AW Customer Portal - MyCommunications Area. We thank you beforehand for the information given.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.