# Lockheed Alert Service Bulletin A382J-53-004: No revision named

- Rights: © LOCKHEED MARTIN CORPORATION. Filed by the FAA in regulations.gov docket FAA-2023-1209; AD 2023-11-10 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Lockheed Alert Service Bulletin A382J-53-004](https://openairdocs.org/service-documents/lockheed/a382j-53-004.md)
- Title as filed: A382J-53-004
- Pages: 19
- PDF: https://openairdocs.org/files/sha256/ef/5c/ef5cc414ef43bca88517a20aaece19341b4584568c5e3177230d3090f7508e81
- Page: https://openairdocs.org/service-documents/lockheed/a382j-53-004/file/ef5cc414ef43

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

Page 1 of 19
A382J-53-004
THIS DOCUMENT CONTAINS COMMERCIAL PROPRIETARY TECHNICAL DATA OF LOCKHEED MARTIN CORPORATION AND OTHERS. USE, COPYING AND/OR DISCLOSURE OF THE TECHNICAL DATA CONTAINED HEREIN IS GOVERNED BY THE TERMS OF LOCKHEED MARTIN
CORPORATION'S LM-100J SALES CONTRACT WITH THE CUSTOMER. 
© 2023 LOCKHEED MARTIN CORPORATION. 
EXPORT CONTROLLED INFORMATION
WARNING - This document contains data whose export is restricted by the Arms Export Control Act (Title 22, U.S.C., Sec 2751, et seq.) as 
amended, or the Export Administration Act (Title 50, U.S.C., App 2401 et seq.) as amended. Violations of these export laws are subject to 
severe criminal and civil penalties.
March 27, 2023
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
FUSELAGE - INSPECTION OF 342986-13/-14/-19/-20 LONGERON FOR POTENTIAL OVERHEATING
1. PLANNING INFORMATION
A. EFFECTIVITY
(1) This Service Bulletin is applicable to model 382J FAA Certificated Hercules aircraft. For this aircraft 
model, aircraft within the following serial range are affected: Lockheed Martin serial numbers 5854, 
5889, 5894, and 5956.
(2) Spares - This Service Bulletin is applicable to all spare 342986-13/-14/-19/-20 Longerons held in stock.
B. REASON
(1) The 342986-13/-14/-19/-20 Longerons may have been exposed to excessive hot forming temperatures 
during manufacturing. Exposure to the higher temperatures will reduce the material strength properties 
of the longerons.
(2) Lockheed Martin Aeronautics Company recommends that this inspection be accomplished on each 
affected aircraft within 35 days after receipt of this Service Bulletin, and on any affected spare prior to 
installation on the aircraft.
C. DESCRIPTION
This Service Bulletin provides instructions for a conductivity test and follow-on hardness test, if required, for 
342986-13/-14/-19/-20 Longerons. Depending on aircraft serial number, 342986-13/-14 longerons fabricated 
from 7075 extrusion or 342986-19/-20 longerons fabricated from 7055 extrusion may be installed.
D. APPROVAL
(1) The aircraft owner/operator will make an appropriate entry in the aircraft log records upon completion of 
this Service Bulletin.
(2) When the work has been completed on each affected aircraft, please complete the attached Figure 4 
and Figure 5 tables along with a Notice of Service Bulletin Compliance and e-mail to 
hercules.support@lmco.com.
E. MANPOWER
The manpower estimates provided have not been validated and are estimates only. These estimates are 
provided only as a convenience for aircraft owner/operator planning purposes. The estimated man-hours 
listed include the following procedures: equipment preparation, gaining access to work location, inspection, 
closing work location, and updating aircraft log records, as applicable. It is estimated that approximately 20 
man-hours (a crew of 2 qualified technicians) will be required to accomplish the work described herein on 
each affected aircraft. This will take approximately 10 hours elapsed time while the aircraft is out of service.

### Page 2

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 2 
March 27, 2023A382J-53-004
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
NOTE: This Service Bulletin is based upon the configuration of the aircraft as it was delivered from 
Lockheed Martin Aeronautics Company. Previous service bulletins issued by Lockheed Martin 
Aeronautics Company have been considered in the preparation of this Service Bulletin, but no 
consideration has been given to peculiar changes made to the aircraft by the owner/operator 
since its delivery.
F. MATERIAL - COST AND AVAILABILITY
Refer to Paragraph 3 for a complete list of materials to inspect each aircraft. 
Requirements for the materials are based upon inspection findings. Materials required to accomplish this 
Service Bulletin for each aircraft and affected spare will be provided by the aircraft owner/operator.
G. TOOLING - PRICE AND AVAILABILITY
This test equipment will be furnished by the aircraft owner/operator.
H. WEIGHT AND BALANCE
None.
I. REFERENCES
J. OTHER PUBLICATIONS AFFECTED
None.
Stock Number Part Number Nomenclature
6635-00-803-7596
6635-00-996-1417
Magnatest FM-110 or 
Magnatest ED-500 unit (or 
similar meeting ASTM E1004)
Electrical Conductivity Meter
5305-01-053-6482 Wilson M-51
(or similar meeting ASTM E110)
Portable Rockwell Hardness 
Tester
Corrosion Prevention and Control Manual
Data Module Control Number DMC-L382-A-20-10-04-00A-353A-A
DMC-L382-A-52-00-03-00A-913A-A
Job Guide

### Page 3

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 3
A382J-53-004March 27, 2023
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
2. ACCOMPLISHMENT INSTRUCTIONS
WARNING: ENSURE THAT ALL APPLICABLE SAFETY PRECAUTIONS ARE OBSERVED WHILE 
ACCOMPLISHING THE WORK PRESCRIBED IN THIS PUBLICATION.
CAUTION: FAILURE TO PERFORM TESTING BETWEEN TEMPERATURE RANGES OF 50 TO 95 °F WILL 
RESULT IN INCORRECT RESULTS.
NOTE: Some steps in the Accomplishment Instructions have been identified as Required for Compliance (RC). 
If this Alert Service Bulletin is mandated by an Airworthiness Directive (AD) by the Federal Aviation 
Administration (FAA), the steps identified as RC must be done to comply with the AD. Steps not 
identified with RC are recommended and may be deviated from; done as a part of other actions; or done 
with accepted methods different from those given in the Service Bulletin if the steps can be done and the 
airplane returned to a serviceable condition.
These work instructions refer to methods, techniques, and practices described in other referenced 
documents. When the words "refer to" are used and there are other acceptable methods, techniques, 
and practices (including tools, equipment, and test equipment) those acceptable methods, techniques, 
and practices (including tools, equipment, and test equipment) may be used to complete the work. When 
the words "in accordance with" are included in the instruction, the methods, techniques, and practices 
specified (including tools, equipment, and test equipment) in the referenced document must be used.
If any of the below steps cannot be performed as written, contact Lockheed Martin Aeronautics Company 
for troubleshooting instructions.
A. Ensure 342986-13/-14/-19/-20 Longeron is not in direct sunlight and is not hot to the touch. If longeron is 
found to be hot to the touch, reposition the aircraft to be out of direct sunlight if possible or move aircraft into 
hangar and wait until temperature of the longeron stabilizes between 50 to 95 °F.
B. Prepare aircraft for maintenance in accordance with applicable Job Guide.
C. Open cargo ramp to ground position in accordance with DMC-L382-A-52-00-03-00A-913A-A.
D. RC - Perform conductivity check on 342986-13/-14/-19/-20 Longeron as follows:
WARNING: ISOPROPYL ALCOHOL IS FLAMMABLE AND TOXIC TO SKIN, EYES, AND RESPIRATORY 
TRACT. AVOID SKIN AND EYE CONTACT. GOOD GENERAL VENTILATION IS NORMALLY 
ADEQUATE. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY TO PERSONNEL.
(1) The surface of the longeron to be inspected shall be free of dirt, grease, oil, or other contaminants prior 
to performing any conductivity measurements. Clean area with ASTM D 770 Isopropyl Alcohol. Wipe 
surface dry. Do not allow alcohol to dry on surface. 
CAUTION: FAILURE TO PERFORM CONDUCTIVITY TESTING BETWEEN TEMPERATURE RANGES OF 50 
TO 95 °F WILL RESULT IN INCORRECT RESULTS.
(2) Place tape measure just aft of starting location of 342986-13/-14/-19/-20 Longeron (FS 737), at 
approximately FS 739. See Figure 1, Sheet 2. Extend tape measure along the length of the longeron 
past the location at which the ramp and door come together, approximately FS 869. See red circled 
area on Figure 1, Sheet 3. Keep tape measure taut by securing tape measure with adhesive tape along 
the length of the longeron.

### Page 4

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 4 
March 27, 2023A382J-53-004
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
CAUTION: ENSURE THAT THE 342986-13/-14/-19/-20 LONGERON, CONDUCTIVITY METER, AND 
CONDUCTIVITY STANDARDS ARE WITHIN 5 °F OF EACH OTHER. FAILURE TO PROPERLY 
STANDARDIZE THE CONDUCTIVITY METER AND APPLY LIFT OFF COMPENSATION WILL 
RESULT IN AN INCORRECT CONDUCTIVITY READING.
(3) Standardize Magnatest FM-110 or Magnatest ED-500 unit in accordance with 
DMC-L382-A-20-10-04-00A-353A-A.
(4) Using standardized Magnatest FM-110 or Magnatest ED-500 unit, measure the conductivity in the 
342986-13/-14/-19/-20 Longeron beginning at the curved end of the longeron, taking the first 
measurement 12 inches from FS 739 or whichever location is first accessible and not blocked by 
obstructions such as rivets or end fittings in accordance with DMC-L382-A-20-10-04-00A-353A-A. See 
Figure 2. Continue taking measurements every four inches along the vertical flange of the longeron, 
stopping eleven feet from FS 739. The first 0 to 2.5 feet of the longeron are not typically accessible, 
however conductivity measurements shall be taken where possible within this 2.5 foot section. If a 
measurement is not able to be taken at a test location, mark location on Figure 4 and Figure 5 as “no 
access” and continue to next text location. Record results in Figure 4 and Figure 5. 
(5) Take three additional conductivity measurements in approximately four inch intervals, at the unformed 
end of the longeron which starts approximately eleven feet aft from FS 739. The exact location of these 
measurements is not critical, but the test shall be performed in the vertical flange of the longeron as 
shown in Figure 2, not near a large formed tang, and not blocked by obstructions such as rivets or end 
fittings. Record results in Figure 4 and Figure 5.
(6) If conductivity measurements at the unformed end recorded in Figure 4 or Figure 5 are less than or 
equal to 36% IACS then the longeron is most likely Part Number 342986-13 (left) and 342986-14 
(right) 7075-T6511. In this case, if conductivity does not exceed 39.0% IACS along the entire 
accessible length, the sloping longeron has the properties needed to perform its function and does not 
require further testing. If conductivity exceeds 39.0% IACS at any location, hardness testing is 
required.
(7) If the conductivity measurements at the unformed end recorded in Figure 4 or Figure 5 is greater than 
36% IACS then the longeron is 7055 Part Number 342986-19 (left) and 342986-20 (right) and may be 
either T74511 or T76511. In this case, if conductivity does not exceed 40.0% IACS along the entire 
accessible length, the sloping longeron has the properties needed to perform its function and does not 
require further testing. If conductivity exceeds 40.0% IACS at any location, hardness testing is 
required.
E. RC - If hardness testing was determined to be required in either Step 2.D.(6) or (7), perform a Rockwell 
Hardness Test as follows:
CAUTION: FAILURE TO PERFORM HARDNESS TESTING BETWEEN TEMPERATURE RANGES OF 50 TO 
95 °F WILL RESULT IN INCORRECT RESULTS.
(1) For each location where a hardness testing was determined to be required in either Step 2.D.(6) or (7), 
mark the location as shown in Figure 3, Sheet 1, and remove the tape measure.
(2) For each marked location, ensure Wilson M-51 Portable Rockwell Hardness Tester, or similar portable 
hardness tester meeting ASTM E110, can be clamped in the desired measurement location as shown 
in Figure 3, Sheet 2. Some locations may be obstructed by rivets or other assemblies as shown in 
Figure 3, Sheet 3. Finishes should not be removed in obstructed locations. Mark obstructed locations 
on Figure 4 and Figure 5 as “no access”.

### Page 5

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 5
A382J-53-004March 27, 2023
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
WARNING: FINISHES CONTAIN HEXAVALENT CHROMIUM. HEXAVALENT CHROMIUM FINISHES ARE 
TOXIC TO SKIN, EYES, AND RESPIRATORY TRACT WHEN AIRBORNE. AVOID SKIN AND EYE 
CONTACT. FOLLOW LOCAL PROCEDURES FOR HEXAVALENT CHROMATED PPE. FAILURE 
TO COMPLY MAY RESULT IN SERIOUS INJURY TO PERSONNEL.
(3) Remove finishes in unobstructed locations down to bare metal in the area to be hardness tested in an 
area one inch in diameter. See Figure 3, Sheet 4.
(4) Standardize Wilson M-51 Portable Rockwell Hardness Tester, or similar portable hardness tester 
meeting ASTM E110 in accordance with manufacturer’s directions. This shall include performing a pre 
and post test verification and standardizing the tester by performing a hardness test on a calibrated 
test block that is within 15 Rockwell points of the material to be tested.
(5) Using standardized Wilson M-51 Portable Rockwell Hardness Tester, or similar portable hardness 
tester meeting ASTM E110, measure 342986-13/-14/-19/-20 Longeron hardness at each location at 
which finishes have been removed. When clamping the hardness tester, place a steel shim, 2 by 1 by 
1/8 inch, underneath the longeron before the tester is installed to ensure compliant installation. See 
Figure 3, Sheet 5. Record results in Figure 4 and Figure 5. After testing is complete, there will be 
hardness test indentations as shown in Figure 3, Sheet 6. 
(6) If all hardness readings are 80 Rockwell B or above, the 342986-13/-14/-19/-20 Longeron is 
acceptable and no further inspection is required, proceed to Step 2.E.(7). Otherwise, if any hardness 
reading is below 80 Rockwell B, Lockheed Martin Aeronautics Company must review results to 
determine further actions. Submit all conductivity and hardness inspection results as recorded on Left 
Hand and Right Hand Longeron Inspection Results Forms as shown in Figure 4 and Figure 5 as an 
attachment to the address below.
(7) Treat bare metal exposed in Step 2.E.(3) as follows:
WARNING: ISOPROPYL ALCOHOL, COLORED CHEMICAL CONVERSION COATING, EPOXY PRIMER, AND 
POLYURETHANE ARE FLAMMABLE AND TOXIC TO SKIN, EYES, AND RESPIRATORY TRACT. 
AVOID SKIN AND EYE CONTACT. GOOD GENERAL VENTILATION IS NORMALLY ADEQUATE. 
FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY TO PERSONNEL.
(a) Clean areas with ASTM D 770 Isopropyl Alcohol. Wipe surface dry. Do not allow alcohol to dry 
on surfaces.
(b) Apply MIL-DTL-81706 Colored Chemical Conversion Coating to areas in accordance with 
Corrosion Prevention and Control Manual.
(c) Touch up finish with two coats of MIL-PRF-23377, Type I, Class C2, Epoxy Primer, and two 
coats of MIL-PRF-85285, Type I, Polyurethane. Match color to aircraft.
F. If inspection results were not submitted in Step 2.E.(6), complete Figure 4 and Figure 5 Inspection Results 
(positive or negative) and return to the Customer Support Center at the address below.
G. Close cargo ramp in accordance with DMC-L382-A-52-00-03-00A-913A-A.
H. Restore aircraft to service in accordance with applicable Job Guide.

### Page 6

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 6 
March 27, 2023A382J-53-004
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
NOTE: If assistance is needed, contact your local Lockheed Martin Aeronautics Company representative, or the 
Customer Support Center in Marietta, Georgia, USA, as follows:
TELEPHONE: (770) 494-9131
FAX: (770) 494-9122
E-MAIL: hercules.support@lmco.com
MAIL: Lockheed Martin Aeronautics Company
86 South Cobb Drive
Dept. 3D3M00, Zone 0591
Marietta, GA 30063, USA

### Page 7 (OCR)

HERCULES  Lockheed Martin Aeronautics Company
Marietta, Georgia 30063
ALERT SERVICE BULLETIN
FS 1023
FS 869-
342986-()
LONGERON
(REF)
FS 737
WL
140.0
1-5637-001
342986-13/-14/-19/-20 Longeron Location and Inspection Details
Figure 1, Sheet 1 of 3
March 27, 2023  USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.  A382J-53-004
Page 7

### Page 8

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 8 
March 27, 2023A382J-53-004
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
342986-13/-14/-19/-20 Longeron Location and Inspection Details
Figure 1, Sheet 2
Start of Tape Measure Location

### Page 9

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 9
A382J-53-004March 27, 2023
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
342986-13/-14/-19/-20 Longeron Location and Inspection Details
Figure 1, Sheet 3
End of Tape Measure Location

### Page 10

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 10 
March 27, 2023A382J-53-004
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
Conductivity Test Probe Placement
Figure 2

### Page 11

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 11
A382J-53-004March 27, 2023
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
Hardness Tester Placement and Testing Details
Figure 3, Sheet 1 of 6
Marking Hardness Test Locations

### Page 12

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 12 
March 27, 2023A382J-53-004
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
Hardness Tester Placement and Testing Details
Figure 3, Sheet 2
Hardness Tester Clamped on Longeron

### Page 13

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 13
A382J-53-004March 27, 2023
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
Hardness Tester Placement and Testing Details
Figure 3, Sheet 3
Rivet Obstruction

### Page 14

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 14 
March 27, 2023A382J-53-004
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
Hardness Tester Placement and Testing Details
Figure 3, Sheet 4
Removing Finishes
Finishes Removed

### Page 15

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 15
A382J-53-004March 27, 2023
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
Hardness Tester Placement and Testing Details
Figure 3, Sheet 5
Steel Shim

### Page 16

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 16 
March 27, 2023A382J-53-004
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
Hardness Tester Placement and Testing Details
Figure 3, Sheet 6
Post Hardness Testing Indents

### Page 17 (OCR)

HERCULES  Lockheed Martin Aeronautics Company
Marietta, Georgia 30063
ALERT SERVICE BULLETIN
Left Hand Side Longeron Inspection
Aircraft Information:
Date of Inspection.
Customer Tail No.
LM Aero Serial No.
Flight Hours
Temperature
Longeron Part Number
Fuselage  Conductivity (% IACS)  Hardness (Rockwell B)  Comments
Station  1st  2nd  3rd
Left Hand Side Longeron Inspection Results
Figure 4
March 27, 2023  USE, COPYING, AND/OR DISCLOSURE IS GOVER  HE TITLE PAGE OF THIS DOCUMENT.  A382J-53-004
Page 17

### Page 18 (OCR)

HERCULES  Lockheed Martin Aeronautics Company
Marietta, Georgia 30063
ALERT SERVICE BULLETIN
Right Hand Side Longeron Inspection
Aircraft Information:
Date of Inspection.
Customer Tail No.
LM Aero Serial No.
Flight Hours
Temperature
Longeron Part Number
Fuselage  Conductivity (% IACS)  Hardness (Rockwell B)  Comments
Station  1st  2nd  3rd
Right Hand Side Longeron Inspection Results
Figure 5
A382J-53-004  USE, COPYING, AND/OR DISCLOSURE IS  HE TITLE PAGE OF THIS DOCUMENT.  March 27, 2023
Page 18

### Page 19

USE, COPYING, AND/OR DISCLOSURE IS GOVERNED BY THE STATEMENT ON THE TITLE PAGE OF THIS DOCUMENT.
Page 19
A382J-53-004March 27, 2023
HERCULES Lockheed Martin Aeronautics CompanyMarietta, Georgia 30063
ALERT SERVICE BULLETIN
3. MATERIAL INFORMATION
A. The following consumable materials are required to inspect each aircraft: 
_______#______                                                                                                
File:   I-5638
QUANTITY PART NUMBER NOMENCLATURE NOTE
A/R ASTM D 770 Isopropyl Alcohol 1
A/R MIL-DTL-81706 Colored Chemical Conversion Coating 1
A/R MIL-PRF-23377, Type I, Class C2 Epoxy Primer 1
A/R MIL-PRF-85285, Type I Polyurethane 1
NOTE: 1. Local purchase/local supply item.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.
