# Pacific Scientific Service Bulletin 25-1111432

Copy: No revision named ("U.S. DOT/FAA - SB 25-1111432"), 7 pages: PDF https://openairdocs.org/files/sha256/5e/cb/5ecb6ec367a6d59b12a4d28017565641f7e92366f9dbd43d98d4a516278e9ef4; text https://openairdocs.org/service-documents/pacific-scientific/sb-25-1111432/file/5ecb6ec367a6.md. Rights: © Pacific Scientific. Filed by the FAA in regulations.gov docket FAA-2013-0752; AD 2021-07-13 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Pacific Scientific](https://openairdocs.org/service-documents/pacific-scientific.md)
- Type: Service bulletin (Service Bulletin)
- Number: 25-1111432
- Page: https://openairdocs.org/service-documents/pacific-scientific/sb-25-1111432

## ADs that cite it (2) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2024-26-02](https://openairdocs.org/ad/2024-26-02.md), effective Mar 7, 2025: No revision named
- [AD 2021-07-13](https://openairdocs.org/ad/2021-07-13.md), effective May 11, 2021: No revision named

Also cited in [2 proposed ADs](https://openairdocs.org/service-documents/pacific-scientific/sb-25-1111432/proposed.md).

## Text (7 pages)

Rights: © Pacific Scientific. Filed by the FAA in regulations.gov docket FAA-2013-0752; AD 2021-07-13 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

SB 25-1111432 
 
SERVICE BULLETIN  
 
 SB 25-1111432 
PAGE 1 OF 7 
May 22, 2007 
TO: Owner/Operators of Pacific Scientific Company Restraint 
Systems using Buckle Assembly Part Numbers 1111430-XX 
and 1111475-XX.  
 
SUBJECT: Information regarding the potential failure of the Guarded 
Rotary Buckle plastic handle. 
 
PURPOSE: This Service Bulletin (SB) identifies suspect Buckle 
Assemblies and advises operators to return them to Pacific 
Scientific for exchange/replacement. 
 
1. INTRODUCTION  
Pacific Scientific has recently received field reports of several instances of cracking on 
the guarded rotary buckle plastic handle.  The buckle assemblies returned to and 
examined by Pacific Scientific had large, readily apparent cracks throughout the plastic 
buckle handle.  Pacific Scientific is investigating the cause of these cracks. 
 
Preliminary testing performed by Pacific Scientific on buckle assemblies with cracked 
plastic handles indicates that in some circumstances when a load is placed on the 
restraint system, the straps may not release as intended when the buckle is rotated.  
Pacific Scientific therefore recommends the mandatory, immediate replacement of the 
affected buckle assemblies. 
    Figure 1 
 
 
Part Number  
1111430-XX or 1111475-XX.

### Page 2

SB 25-1111432 
 
SERVICE BULLETIN  
 
 SB 25-1111432 
PAGE 2 OF 7 
May 22, 2007 
3. SCOPE  
This SB only involves Buckle Assemblies 1111430-XX and 1111475-XX with a date of 
manufacture between November 2004 and May 2007. These buckle part numbers are 
integral to Restraint Systems assemblies listed in Appendix 1, (see pg 7) . 
 
This Service Bulletin does not affect other types of Pacific Scientific plastic buckle 
handles or metal handle rotary buckles. 
 
4. REFERENCE  
ACMM 25-11-59 “Restraint Systems”.    
See;   http://www.pacscimiami.com/2004RestraintInspectionData.pdf 
 
5. COMPLIANCE  
Mandatory for guarded rotary buckles which contain suspect handles. Replacement 
parts will be made available at no charge to owners and operators for a period of six 
months from the date is issue of this document.  Thereafter, normal R&O charges will 
apply. 
 
6. SAFETY   
No special safety precautions in performing this SB. 
 
6. TOOLING  
No special tools or fixtures are required.  A simple shim to release the fixed position 
strap fitting from the buckle is required. (See Figure 3) 
 
7. MANPOWER  
Inspection and replacement of buckle from system should take one person 
approximately 0.1 hour. A Video clip of the process is posted at www.pacscimiami.com 
 
8. INSPECTION  
Suspect handles may be identified by checking the PN on the reverse side of the buckle 
assembly against the part numbers listed in Appendix 1 of this service bulletin. 
 
Suspect handles may also be identified by measuring the thickness of the handle vane.  
Measurement to determine suspect handles will be accomplished in accordance with 
Figure 3.   
ACCEPTABLE PARTS will have a vane dimension LESS than   .125  INCH 
SUSPECT PARTS will have a vane dimension GREATER than  .130  INCH 
 
A GOLD center logo plus oversize vanes are indicators of suspect parts. Handles that 
have been reworked are marked with a BLUE logo on the center button. (See figure 4). 
These handles are acceptable and do not require replacement. 
 
In case of question or doubt of the status of the restraint in question, please contact us 
via email at sb@pacscimiami.com or (626) 228 8841

### Page 3

SB 25-1111432 
 
SERVICE BULLETIN  
 
 SB 25-1111432 
PAGE 3 OF 7 
May 22, 2007 
 
Figure 2 
 
ACCEPTABLE HANDLE 
 
SUSPECT HANDLE 
 
 
 
 
Figure 3 
 
Determination of Vane dimension  
 
 
 
Figure 4 
 
 
 
 
REWORKED HANDLE HAS 
BLUE LOGO BUTTON :    ACCEPTABLE 
 
 
Measure vane no closer than 1/8th 
inch and no more than 1/2 inch 
away from central hub. 
ACCEPTABLE HANDLE: 
LESS than  .125  INCH 
 
SUSPECT HANDLE: 
GREATER than .130  INCH

### Page 4

SB 25-1111432 
 
SERVICE BULLETIN  
 
 SB 25-1111432 
PAGE 4 OF 7 
May 22, 2007 
9. PROCEDURES  
All suspect buckle assemblies (buckle assembly only) shall be removed from service for 
return to Pacific Scientific for exchange/replacement. 
 
Remove suspect buckle from fixed lap belt by sliding a shim between the fixed belt fitting 
and back of buckle assembly;  
 
1) Insert a piece of thin metal stock into the slot of the rotary buckle and push inward 
between the fitting and the buckle locking mechanism  (see Figure 5) 
2)  Pull the strap from the buckle 
3)  Remove the buckle pad as necessary. 
 
A Video clip of removal process is available at www.pacscimiami.com  
 
Figure 5 
 
 
To reassemble with acceptable buckle, insert lap belt into new buckle. Fixed strap 
location is indicated by appropriate marking on buckle housing. Additional detailed 
instructions are available in ACMM 25-11-59 should they be required. 
 
10. MATERIAL OR SERVICE  
Special contact points have been established in order to manage this Service Bulletin. 
 
Contact one of the following for instructions, replacement parts and technical questions: 
 
sb@pacscimiami.com     or    1 (626) 228-8841

### Page 5

SB 25-1111432 
 
SERVICE BULLETIN  
 
 SB 25-1111432 
PAGE 5 OF 7 
May 22, 2007 
Standard Contacts 
 
Pacific Scientific Aviation Services 
11700 N.W. 102nd Rd. # 6 
Miami, Florida 33178 
United States 
Ph:   305-477-4711 
Fax: 305-477-9799 
Contact: Edel Mena 
 
Pacific Scientific UK Ltd. 
Howarth Road,  Maidenhead 
Berkshire SL6 1AP 
United Kingdom 
Ph:   44-1628 68-2200 
Fax: 44-1628-68 2250 
Contact: Ross Hamilton 
 
Pacific Scientific Germany 
Unit 6 Hagen Park 
Miramstrasse 74 
34123 Kassel 
Germany  
Tel: + 49 (0) 561 57981 0  
Fax: + 49 (0) 561 57981 25  
Contact: Holger Laue 
 
 
 
11. EQUIPMENT ORDE RING PROCEDURES 
In order to maintain unit traceability, please return all suspect parts (buckle only) 
to your local Pacific Scientific facility with your company’s no-charge repair 
purchase order.  Units will be repaired or replaced in a timely manner and 
returned with FAA 8130-3 or EASA Part 145 Form 1 tags. 
 
Should you require replacement parts in advance of removal, please identify the 
specific buckle part numbers and quantities that you will require, and contact 
your local Pacific Scientific repair center for instructions 
 
Additional details and instructions are available at www.pacscimiami.com

### Page 6

SB 25-1111432 
 
SERVICE BULLETIN  
 
 SB 25-1111432 
PAGE 6 OF 7 
May 22, 2007 
 
12. FAQ Frequently Asked Questions  
 
Q1: Are any other Pacific Scientific  restraint Affected by this SB? 
  A: No other types of restraints or restra int components are affected by this condition or SB. 
 
Q2: Do I remove my entire system and send it in?  
  A: No, follow instructions in this bulleti n and remove the buckle only. The straps need not be 
returned. 
 
Q3: Can I remove the handle and do the repair myself? 
  A: No, repairs other than by Pacific Scientif ic are not authorized. Return to service tags 
must be issued by Pacific Scientific. 
 
Q4: How soon should I send in my buckle? 
  A: The buckle must be immediately remov ed from service if the handle shows visible 
cracks.  Handles which do not show visible cracks should be replaced as soon as 
possible. Replacement parts will be made available at no charge for a period of six 
months.  Thereafter, normal R&O charges will apply.  
 
Q5:  Will I receive a new or repair buckle? 
  A: Repaired buckles will be sent to operators. 
 
Q6:   How long does it take to fix the unit? 
  A: Pacific Scientific currently esti mates a turn around time of four days.  
 
Q7: How much will the rework cost? 
  A: All exchange/replacements will be Free of C harge within 6 months from the date of this 
document. 
 
Q8: Where do I send my unit? 
  A: Issue your standard no charge repair order  referencing this SB and forward to Pacific 
Scientific’s Miami, London, or Kassel, Germany repair center per the SB instructions. 
 
Q9: What should I do if my buckle handle is cracked? 
A:  The buckle assembly should be i mmediately removed from service. 
Contact Pacific Scientific for exchange/replacement. 
  
Q10: What can happen if the buckle handle is cracked?  
  A: Under some circumstances, testing has shown that the straps might not release when 
the handle is rotated.  There have been no reports of this happening in the field.  Pacific 
Scientific is replacing the buckle handles as a precaution.  
  
Q11: Who should I contact with questions?  
   A: Contact any of the following; 
o 1 (626) 228 8841  
o SB@pacscimiami.com  
o Miami; Contact : Edel Mena      305-477-4711 
o UK; Contact:  Ross Hamilton        44-1628 68-2200 
o Germany; Contact:  Holger Laue        49 (0) 561 57981 0 
o www.pacscimiami.com      www.pacscieurope.com

### Page 7

SB 25-1111432 
 
SERVICE BULLETIN  
 
 SB 25-1111432 
PAGE 7 OF 7 
May 22, 2007 
APPENDIX 1 
 
Restraint system part numbers potentially affected. 
 
1 0108084-05 30 1111432-01 59 2000014-83 
2 0108084-07 31 1111460-01 60 2000021-05-001 
3 0108092-01 32 1111460-03 61 2000029-01 
4 0108092-03 33 1111475-XX 62 2000029-03 
5 0108904-01 34 1117119-01 63 2000029-101 
6 0108904-03 35 1117119-03 64 2000029-121 
7 0108904-05 36 1117119-05 65 2000029-55 
8 0108904-301 37 1117119-07 66 2000029-71 
9 0108904-303 38 1117148-01 67 2000029-73 
10 0108904-53 39 1117148-03 68 2000037-05 
11 0108904-55 40 1117148-05 69 2000067-01 
12 0108904-91 41 1117148-07 70 2000091-05-001 
13 0108904-93 42 1117148-09 71 2000104-23-226 
14 0118013-01 43 1117148-11 72 2000104-43-226 
15 0118026-05 44 1117148-133 73 2000108-01-001 
16 0118030-07 45 1117148-15 74 2000108-03-001 
17 0118037-01-001 46 1117148-17 75 2000111-01 
18 0118037-03-001 47 1117148-27 76 2000111-03 
19 0118038-01 48 1117148-29 77 2000114-03-001 
20 1106193-03 49 1117148-33 78 2000115-101 
21 1106193-13 50 1117148-35 79 2100011-03 
22 1106193-53 51 1117181-01 80 2100023-15-001 
23 1109012-03-001 52 1117433-21 81 2100025-01-001 
24 1109026-01-001 53 1117433-23 82 2100025-01-066 
25 1109026-11-001 54 2000013-01-001 83 2100025-01-104 
26 1109026-31-001 55 2000013-03-001 84 2100025-01-243 
27 1111131-03 56 2000014-01 85 2100025-03-066 
28 1111147-01-001 57 2000014-03 86 2100025-03-104 
29 1111430-XX 58 2000014-81 87 2100025-03-243 
 
END

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.
