# Parker Service Bulletin 469000-27-003

Copy: Revision 1 ("Parker SB 469000-27-003SB_R1"), 25 pages: PDF https://openairdocs.org/files/sha256/ec/13/ec13a260a7f8e073842e068cf14d8d24ee8cccfdee57a7c2d21ab6e1ab88b59a; text https://openairdocs.org/service-documents/parker/sb-469000-27-003/file/ec13a260a7f8.md. Rights: © Parker. Filed by the FAA in regulations.gov docket FAA-2019-1024; AD 2020-11-01 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Parker](https://openairdocs.org/service-documents/parker.md)
- Type: Service bulletin (Service Bulletin)
- Number: 469000-27-003
- Latest revision known: 469000-27-003, Revision 1, dated October 11, 2017 (OpenAirDocs)
- Page: https://openairdocs.org/service-documents/parker/sb-469000-27-003

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2020-11-01](https://openairdocs.org/ad/2020-11-01.md), effective Jul 27, 2020: Revision 1

## Text (25 pages)

Rights: © Parker. Filed by the FAA in regulations.gov docket FAA-2019-1024; AD 2020-11-01 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

Customer Support Operations 
 SERVICE BULLETIN  
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 1 of 1 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
FLIGHT 
CONTROLS   
FLIGHT CONTROL REMOTE ELECTRONIC 
UNITS, PART NUMBER (P/N) 469000   
REU SOFTWARE UPGRADE   
REVISION TRANSMITTAL SHEET   
This page transmits Revision 1 for Service Bulletin 469000-27-003.   
SUMMARY:   
Page 6 Paragraph 3.F.(2) Revised:  All power should be removed from the aircraft during 
this operation.   
To:  Prior and during performing this Service Bulletin, GAC is to 
ensure that all aircraft power is removed (the proper circuit 
breakers are pulled and collared) to the flight control surfaces 
which will receive the software upgrade in accordance with the 
Gulfstream G650 Aircraft Maintenance Manual and ASC-069 
(REU).   
   
No additional work is required for parts previously modified by prior issue of this Service Bulletin.   
REVISION HISTORY:   
Initial Issue May 23, 2017    
Revision 1 Oct 11, 2017

### Page 2 (OCR)

THIS PAGE IS INTENTIONALLY LEFT BLANK

### Page 3

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 1 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
FLIGHT 
CONTROLS   
FLIGHT CONTROL REMOTE ELECTRONIC 
UNITS, PART NUMBER (P/N) 469000   
REU SOFTWARE UPGRADE   
1. PLANNING INFORMATION   
A. Effectivity   
This Service Bulletin is applicable to the Parker G650 Remote Electronics Unit (REU) P/N 469000-ALL 
configuration with Software (SW) Label 34.  See P/N cross-reference table below.   
Table 1   
PART NUMBER CROSS REFERENCE 
PARKER P/N GULFSTREAM P/N 
469000-1007 60P2715001Z004 
469000-1009 60P2715001Z004 
469000-1011 60P2715001Z005 
469000-1013 60P2715001Z007 
469000-1017 60P2715001Z006 
469000-1019 60P2715001Z006 
NOTE:  REU P/N 469000-1015 (Gulfstream P/N 60P2715001Z007) configuration will have software  
Label 35 installed prior to shipping during original production build.   
B. Concurrent Requirements   
This upgrade may be performed in conjunction with Service Bulletin 469000-27-002.   
C. Reason   
(1) This Service Bulletin provides instructions to upgrade the G650 REU software to Label 35 for 
Command Lane (CL) and Monitor Lane (ML) of the REU P/N 469000.   
(2) REU SW Label 35 incorporates changes as sociated with the LVDT Disconnect Monitor, 
Oscillatory Monitor, implements Spoiler Retract Bias Function, corrects EHSV Current Reporting, 
Rig Offset, Pressure Sensor Range monitor, Resolver PBIT coverage, Force Fight at end of 
stroke, provisions for dispatch relief for EB fault.   
D. Description   
This Service Bulletin informs operators of a REU Software upgrade, and provides an approved 
procedure for Parker authorized technicians to upgrade the REU SW.   
E. Compliance   
Refer to Gulfstream Aerospace Corporation (GAC) Aircraft Service Change, ASC-069 for compliance 
interval.

### Page 4

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 2 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
F. Approval   
The contents of this Service Bulletin have been reviewed and approved by GAC for application on the 
G650 aircraft.   
G. Manpower   
This software upgrade may be accomplished by a crew of one, in 0.25 man-hours.   
H. Weight and Balance   
None.   
I. Electrical Load Data   
One external 28 VDC Power Supply.   
J. Software Accomplishment Summary   
See Accomplishment Instructions in section 3.   
K. References   
(1) Parker 474000GSE1.   
(2) GAC ASC-069.   
L. Other Publications Affected   
Not applicable.   
M. Interchangeability or Intermixability of Parts   
Refer to Gulfstream ASC-069 for the acceptable interchangeability and intermixability of REUs and 
associated components.

### Page 5

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 3 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
2. MATERIAL INFORMATION   
A. Material - Price and Availability   
(1) Option 1  (On aircraft)  
(a) Parker authorized technicians will upgrade units installed on aircraft during maintenance 
period.   
(b) All SW upgrades to be performed by Parker authorized technicians only.   
(2) Option 2  (At Parker facility)   
To implement this software upgrade via product removal and replacement, operators are 
requested to coordinate the return of the unit(s) (or spares) for pricing and scheduling with your 
Gulfstream representative.   
(3) Option 3  (On bench)   
SW loading process to be performed by Parker authorized technicians only.   
B. Provisions herein are available starting May 2017 and remain valid for a period of 36 months after the 
initial issue date of this Service Bulletin.  After that date, contact your Gulfstream representative for 
software upgrade terms and conditions.   
C. Material Necessary for Each Component   
The following part is for each REU required for Option 3.   
Table 1   
NEW P/N KEYWORD OLD P/N QTY DISPOSITION 
NAS1611-019A O-ring  Same   1 Scrap 
D. Material Necessary for Each Spare   
Table 2   
NOMENCLATURE PART NO./TYPE SOURCE 
ESD Cap (J1, J2) 121021-31 (or equivalent NAS837-20C) Parker Hannifin Corporation 
ESD Cap (J3) 121021-27 (or equivalent NAS837-16C) Parker Hannifin Corporation 
Isopropyl Alcohol Federal Specification, TT-I-735 (or equivalent) Commercially Available 
ESD Brush (Soft bristles) SST655 (or equivalent) Gordon Brush Company 
3737 Capitol Ave. 
City of Industry, CA. 90601 
Phone: (323) 724-7777

### Page 6

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 4 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
 Table 2 cont’d.  
NOMENCLATURE PART NO./TYPE SOURCE 
“Top Gun” Ionizing Air Gun 4005105 (or equivalent)  Simco   
2257 N. Penn Road   
Hatfield, PA. 19440 
Phone: 1 (800) 203-3419 
Black Felt Pen   EK-1 (or equivalent) Parker Hannifin Corporation  
Shipping Cap 473996MST1 Parker Hannifin Corporation  
E. Re-identified Parts   
The Software Label Version will be updated to 35 upon completion of this Service Bulletin for the REU 
P/N 469000.  See Figure 24.   
F. Tooling - Price and Availability   
None.   
3. ACCOMPLISHMENT INSTRUCTIONS   
A. General Notes:   
(1) All efforts to incorporate this Service Bulletin can be performed at:   
(a) GAC - Authorized service centers.   
(b) On or off aircraft.   
(2) Work must be accomplished by Parker authorized technicians only.   
(3) Obey all warnings and cautions in the Service Bulletin.   
B. Hardware Requirements   
(1) Parker 474000GSE1 REU G650 hardware requirements.   
(2) Wiring diagram and te st cables:  Parker P/N 469000TF65.   
(3) One external 28 VDC Power Supply to power the REU.

### Page 7

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 5 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
C. Software Requirements   
Parker 474000GSE1 REU G650 has the required software pre-loaded, including Label 35.   
D. Electrostatic Discharge  (ESD) Precaution   
Some types of electronic components are easily damaged by ESD, and they require special handling 
and storage procedures.  ESD is a release of stored electrostatic charge, which has been generated 
by actions such as contact, rubbing or separating materials.  A charge of this type can damage 
electrical and electronic equipment installed in the aircraft.  In some instances, the damage may not be 
immediately evident but can cause progressive component deterioration.   
E. Handling of ESD Sensitive Components and Equipment   
(1) All personnel handling ESD sensitive components  and equipment should receive training in the 
proper handling of such items.  The following ESD handling rules will prevent damage to ESD 
sensitive components and equipment:   
(a) Tools with plastic or insulated handles should not be used around ESD sensitive devices.  
These tools can carry a static charge, which does not readily discharge during the 
grounding process.  Insulated tools should be used only during power on testing of aircraft 
systems to prevent electrical shock to maintenance personnel performing the test.   
(b) When using test equipment, discharge all test  leads to ground prior to connection to the 
ESD sensitive circuit under test.  Use only hand tools that have conductive or static 
dissipative handles or grips.  Test equipment, such as scopes and meters, must be rated for 
use around ESD sensitive components and equipment.   
(c) Portable static control workstations should be used when removing or installing enclosures 
at the aircraft.  Place the removed ESD sensitive equipment on the workstation static 
dissipative work surface.  The workstation should be kept free of any material not required 
to accomplish the assigned task.   
(d) Personnel are required to wear a wrist grounding strap when opening ESD protective 
packaging, see Figure 1.  Avoid touching circuit components or connector pins when 
handling ESD sensitive components or equipment.  Protect ESD sensitive components and 
equipment with protective containers, conductive caps and/ or pin shorting devices.  Store 
and transport ESD sensitive components and equipment in protective containers and seal 
all containers with an ESD warning label.  All loose ESD sensitive components and 
equipment shall be placed into protective containers prior to removing grounding wrist strap.

### Page 8

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 6 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
 
Figure 1   
Proper Aircraft Grounding Steps to Prevent Electrostatic Discharge.   
F. Loading procedures general information.   
(1) Parker 474000GSE1.   
(2) Aircraft Power Requirement:  Prior and during pe rforming this Service Bulletin, GAC is to ensure 
that all aircraft power is removed (the proper circuit breakers are pulled and collared) to the flight 
control surfaces which will receive the software upgrade in accordance with the Gulfstream G650 
Aircraft Maintenance Manual and ASC-069 (REU).   
(3) Technician Training:  This Service Bulletin must be incorporated by Parker authorized 
technicians only.   
G. REU Aircraft Preparation and Configuration   
CAUTION:  REUs SHALL BE DEPOWERED ANY TIME A CONNECTOR IS MATED OR 
DEMATED.

### Page 9

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 7 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
CAUTION:  REUs ARE ELECTROSTATIC DISCHARGE (ESD) SENSITIVE COMPONENTS.  
OBSERVE ALL ESD PRECAUTIONS WHEN TOUCHING, INSPECTING, REMOVING 
OR INSTALLING SUCH COMPONENTS.  DAMAGE CAN OCCUR FROM 
ELECTROSTATIC DISCHARGE.   
CAUTION:  USE CARE WHEN INSTALLING THE REU LOADING HARNESS TO THE REU 
CONNECTOR.  VERIFY PROPER ALIGNMENT, ORIENTATION AND CONNECTOR 
CONDITIONS PRIOR TO INSTALLATION.  TO AVOID EQUIPMENT DAMAGE DO 
NOT FORCE CONNECTION.   
CAUTION:  MAKE SURE THAT THE REU LOADING HARNESS CONNECTOR REMAINS 
PERPENDICULAR TO THE REU AT ALL TIMES WHILE CONNECTED AND THE 
CONNECTION REMAINS UNDISTURBED THROUGHOUT THE PROCESS.  
OTHERWISE, COMPONENT DAMAGE CAN OCCUR.   
NOTE:  Before performing the following steps, GAC will configure the aircraft by providing Parker 
authorized technician(s) clear access to the REU J1 connector per applicable G650 AMM 
and ASC-069.   
NOTE:  For on-bench upgrade, GAC to cover manifold J1 connector with shipping cap P/N 
473996MST1 after REU removal.   
 
(1) Observe all ESD safety precautions.   
(2) Install and connect the ESD wrist strap assembly.   
H. Touch-up / Inspection (On-bench and on aircraft)   
NOTE:  These instructions only apply if the REU is removed from the aircraft and performed on bench 
prior to or after software load.   
(1) Repair of Anodized or Alodined Surfaces (If necessary) 
WARNING:  ISOPROPYL ALCOHOL TT-I-735 OR ASTM D770 IS TOXIC AND FLAMMABLE.  
USE IN A WELL-VENTILATED AREA.  DO NOT BREATHE FUMES. KEEP 
AWAY FROM OPEN FLAME AND OTHER IGNITION SOURCES.  DO NOT LET 
ALCOHOL TOUCH SKIN FOR A LONG TIME.  WASH HANDS WHEN 
COMPLETE.

### Page 10

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 8 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
(a) Repair cosmetic scratches limited to the surf ace finish and/or primer, by first cleaning the 
damaged area with an aluminum oxide abrasive cloth.  Then clean with isopropyl alcohol 
and allow to dry. Use a black felt tip pen for touch up.  To repair cosmetic scratches to the 
base metal surface, blending 20:1 to depths not exceeding 0.005 inch.  Verify repair depth 
using best shop practices.  Then clean with isopropyl alcohol and allow to dry.  Use a black 
felt tip pen for touch-up.   
(b) Shake the pen for 15 seconds to mix contents.  Apply one to two swipes to cover 
scratched area with black color.  Allow 30 minutes of curing time prior to handling.   
(2) Inspection   
(a) Inspect connectors J1, J2 and J3 for pin dama ge.  If bent or damaged, return to GAC for 
subsequent return to Parker.  See Figure 25 and 26 for pictorial view of the REU and 
connector locations.   
WARNING:  ISOPROPYL ALCOHOL TT-I-735 OR ASTM D770 IS TOXIC AND 
FLAMMABLE.  USE IN A WELL-VENTILATED AREA.  DO NOT BREATHE 
FUMES. KEEP AWAY FROM OPEN FLAME AND OTHER IGNITION 
SOURCES.  DO NOT LET ALCOHOL TOUCH SKIN FOR A LONG TIME.  
WASH HANDS WHEN COMPLETE.   
(b) Using an ESD brush, apply light strokes on J1 (on bench), J2 (on aircraft and on bench) 
and J3 (on bench) connector pins with isopropyl alcohol to remove any debris, before 
connecting to the REU.   
WARNING:  COMPRESSED AIR CAN CAUSE AIRBORNE PARTICLES THAY MAY GO 
INTO EYES OR SKIN.  DO NOT USE MORE THAN 15 PSIG (105 KPAG) 
NOZZLE PRESSURE WHEN COMPRESSED AIR IS USED TO DRY 
PARTS.  WEAR EYE PROTECTION.  DO NOT POINT AIR STREAM AT 
YOURSELF OR OTHER PERSONNEL.   
(c) Set the “Top Gun” compressed air pressure between 10-15 psi.   
(d) Aim the nozzle tip to the connector face an d press the release button for approximately 2-3 
seconds in a circular motion to air dry the connectors.   
(e) Check for Foreign Object Damage (FOD).  Repeat steps (b) and/or (d) for any remaining 
debris.   
I. REU Software Loading Process   
(1) To program the G650 REU CL and ML OFP (Operati on Flight Program) software into their flash 
memory, follow the steps below:   
(a) Perform setup of 474000GSE1 per Figure 2.  (Note: GSE is contained within the top block 
with dashed outline).   
(b) Connect the REU Software Programming Cable 469000TF65 per Figure 2.   
NOTE:  There is one USB cable for each of the G650 CL and G650 ML.

### Page 11

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 9 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
(c) 28VDC Power Supply connections   
(1) REU can be powered from an external power source by disconnecting P1 connector 
and connecting the REU Power Test Cable banana plugs in place per Figure 2.

### Page 12 (OCR)

parker
Customer Support Operations
SERVICE BULLETIN
474000GSE1  LAPTOP  474000GSE1-1: COMES
SOFTWARE FIELD LOADER  WITH PRE-LOADED
ANY  ANY  ANY  SOFTWARE INCLUDING
USB  USB  USB  LABEL 35
NOT USED  474000GSE1-2  474000GSE1-3
USB TO RS485  USB TO RS485  USB TO RS485
CONVERTER #3  CONVERTER #1  CONVERTER #2
MCE ONLY  COMMAND LANE (CL  MONITOR LANE (ML)
COM PORT 8  COM PORT 6  COM PORT 7
474000GSE1-4  DB-9  DB-9
SEE NOTE 1
EXTERNAL
POWER SOURCE
POWER SUPPLY
28 VDC
469000TF65 (REU PROGRAMMING
BANANA PLUGS  SOFTWARE CABLE)
2 PLACES  → AIRCRAFT
WIRING
CONNECT THE SOFTWARE
LOADING HARNESS CABLE TO
J1 TO ENABLE PROGRAMMING
AIRCRAFT
WIRING
J2 CONNECTOR IS
REU  NOT REQUIRED FOR
AIRCRAFT HARNESS  IN DISCONNECTED  PROGRAMMING AND  CAN REMAIN CONNECTED
STATE PRIOR TO
PROGRAMMING
AIRCRAFT SIDE  SEE NOTE 3
MANIFOLD
NOTES:
1. RS485 CONVERTERS #1 AND #2 ARE ALREADY CONFIGURED PER 474000GSE1 AS COM PORTS 6
AND 7 TO COMMUNICATE WITH THE REU.
2. REU POWER, COMMAND AND MONITOR TEST PORTS AND ALL CONFIGURATION PINS ARE AVAILABLE
ON THE REU J1 CONNECTOR.
3. J3 CONNECTOR IS NOT REQUIRED FOR PROGRAMMING AND CAN REMAIN MOUNTED ON THE MANIFOLD.
469000-27-003SB_R0 Fig2
Figure 2
REU/UART Data Loader Cable Setup
Initial Issue May 23, 2017  469000-27-003
Rev. 1 Oct 11, 2017  Page 10 of 23
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER-HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER USE
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.

### Page 13

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 11 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
(d) Run the UART Field Loadable Tool from the laptop Start menu:   
“Start > All Programs > UART_FieldProgrammer > UART_FieldProgrammer.exe ” 
sub-menu or click on the desktop UART icon.  Verify that the same screen is displayed 
as shown in Figure 4.   
 
 
Figure 3   
UART Field Loader Tool Icon   
(e) Verify that UART Field Loader Tool version is 1.1.4 or later.   
   
Figure 4   
UART Field Loader Tool Main Menu

### Page 14 (OCR)

Parker
Customer Support Operations
SERVICE BULLETIN
(f)  Select the "UART Data Loader" option from the UART Loader.
UART Field Loader Tool, Version 1.1.4, 03/20/2017
UART Reader:
Read REU CRC Values
Read MCE CRC Value
Read REU Serial Number
Download REU NVM Fault History
Download MCE NVM Fault History
-UART Loader:
UART Data Loader
Upload REU Serial Number
Parker Aerospace 2016 (C)  Quit
Figure 5
UART Data Loader Selection
(g) In the "Select LRU Type" window, select "REU" then click "OK".
• Select LRU Type...
Please select the appropriate LRU type:
© MCE  • REU
OK  Cancel
Figure 6
REU Selection
Initial Issue May 23, 2017  469000-27-003
Rev. 1 Oct 11, 2017  Page 12 of 23
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER-HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER USE
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.

### Page 15

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 13 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
 
(h) In the “Select LRU Label” window, select “Label 35” then click “OK”.   
     
Figure 7   
REU Label 35 Selection   
(i) In the “Upload Password” window, enter the password and click “OK”.   
NOTE: Password is restricted to a Parker authorized technician.   
   
Figure 8   
Password Entry

### Page 16

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 14 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
 
(j) Next, exit the “UART Field Loader Tool” main menu by clicking “OK”.   
 
Figure 9   
UART Field Loader Tool Exit Windows   
(k) W indow may flash quickly during “Wait for processing command”.   
 
Figure 10   
Processing Command Window   
(l) Wait for the UART Field Loadable Tool to  establish the UART connection between the 
laptop and both the Command Lane (CL) and Monitor Lane (ML).   
NOTE:  There will be two UART Data Loader windows displayed on the laptop screen 
during the upload progress as shown in Figure 11.

### Page 17 (OCR)

Parker
Customer Support Operations
SERVICE BULLETIN
150005PRO0-SW OAKI Data Loader 2.00_Production, 2/25/201T, bus cycle (J00 h2) = 1200  150003PROG-SW UART Data Loader 2.6d_Production, 2/23/2017, Bus cycle (100 Hz) = 2182
UART Data Loader (HOST PC)  Version: 2.6d_P_Eng10  UART Data Loader (HOST PC)  Version: |2.6d _P_Eng10
• Used BDS 1350 UART Protocol  Send Preamble data: OFF  I Used BDS 1350 UART Protocol  Send Preamble data: OFF
Select Target CPU  TI TMS320 C33xx (Motorola S-Record 32-bit *.S19)  Select Target CPU TI TMS320 (Motorola S-Record S-Record + +.S19)
& COMport: COM 6  Elapse Time (MSec):  COM port: COM 7  Elapse Time (MSec):
Read from UUT:  Read from UUT:
Product ID:  SW Ver Addr SW Version:  CRC Value:  Product ID:  SW Ver Addr  SW Version:  CRC Value:
0x019601  0x019602  0x3DC002  0x3DC000  OxFFFFFFFF
Send command to UUT to compute its CRC value  Send command to UUT to compute its CRC value
Read from image file:  Read from image file:
Product ID: 0x0000  SW Version:  0x00000095  CRC Value:  0xBA515C92  Product ID:  0x0000  SW Version:  CRC Value  0x253C7DD2
Select image file  C:G650_LOADER REULABEL_35\V2_P20_CL_FLASH.s19  Select image file  C:NG650_LOADER REULABEL_35\G650_ML_Flash_CRC.s19
Flash Program Memory:  End Addr:  0x00019602  Flash Program Memory:  0:003DC000  End Addr:  0x003E7FFF
Upload progress:  Upload progress:
Status:  Programming record 222 of 4803 (000106E0)  Status  Programming record 713 of 3279 (3DE9A9)
Programming is in progress. Please do not power off the unit.
Quit
Figure 11
CL and ML Flash Programming Windows
Once the "Green" traffic light indicates a good solid connection between the laptop
and the REU, the upload process will then start for both CL on the left, and ML on
the right side as shown above.
Verify the correct OFP Label 35 is displayed:
Com 6 CL must display CRC value "0xBA515C92"
Com 7 ML must display CRC value "0x253C7DD2"
Verify the upload progress bar is advancing. Wait for both the CL and ML flash
programming to complete.
If any of the lanes do not upload OFP successfully, an error window will be displayed as
shown in Figure 12 Click "OK" and quit the software for both lanes. Power down the 28
VDC external power supply. Check the REU field loadable cables are properly
connected and make sure the cable wiring is free of defects. Repeat the process from
the beginning, steps 3...(1) (c) through (I) for both lanes. After 5 failed attempts,
disconnect the REU and return to GAC for subsequent return to Parker.
WART ML Upload
Upload Image Status: = FAILED.
OK
Figure 12
UART ML Field Loadable Flash Programming Failure
Initial Issue May 23, 2017  469000-27-003
Rev. 1 Oct 11, 2017  Page 15 of 23
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER-HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER USE
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED

### Page 18 (OCR)

Parker
Customer Support Operations
SERVICE BULLETIN
(n)  If upload is successful, each lane will receive a confirmation as shown below:
UART CL_ Upload  UART ML_ Upload
CRC Matched, Upload Successful  CRC Matched, Upload Successful
OK
Figure 13
UART CL and ML Post Upload with CRC Verification.
(o) Check for CL (Com 6) CRC matching values then click "Quit".
NOTE: Make sure all 3 CRC values "0xBA515C92" match. If not, repeat steps above.
NOTE: If the windows in Step (n) above are blocking the "CRC Value", move the
windows or click the "OK" button to close them.
150003PROG-SW UART Data Loader 2.6d_Production, 2/23/2017, Bus cycle (100 Hz) = 11068
UART Data Loader (HOST PC)  Version: 2.6d_P_Eng10
F Used BDS 1350 UART Protice  Send Preamble data: OFF
Select Target CPU  TI TMS320 C33xx (Motorola 5-Record 32-bit *.519)
COM port: COM 6  Elapse Time (MSec):  157841
Read from UUT:
Product Addr Product ID:  SW Ver Addr  SW Version:  CRC Addr:  CRC Value:
0x000000  05019601  0x00005C92  0:019602  0xBA515C92
Send command to UUT to compute its CRC value  0xBA515C92
| Read from image file:
Product ID:  0:0000  SW Version:  CRC Value:  0xBA515C92
Select image file  CAG650_LOADER REULABEL_35V2_P20_CL_FLASH.$19
Flash Program Memory:  Start Addr:  0:00010000  End Addr:  0100019602
Upload progress:
Status:
Flash programming completed
Quit
Figure 14
UART CL Post Upload with CRC Verification.
Initial Issue May 23, 2017  469000-27-003
Rev. 1 Oct 11, 2017  Page 16 of 23
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER-HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER USE
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.

### Page 19 (OCR)

Parker
Customer Support Operations
SERVICE BULLETIN
(p)  Check for ML (Com 7) CRC matching values then click "Quit".
NOTE: Make sure all 3 CRC values "0x253C7DD2" match. If not, repeat steps above.
NOTE: If the windows in Step (n) above are blocking the "CRC Value", move the
windows or click the "OK" button to close them.
150003PROG-SW UART Data Loader 2.6d_Production, 2/23/2017, Bus cycle (100 Hz) = 14292
UART Data Loader (HOST PC)  Version: 2.6d P_Eng10
FUsed BDS BDS-1350 UART Prot  Send Preamble data:  OFF
Select Target CPU  TI TMS320 F28xx (Motorola S-Record 16-hit *.519)
COM port: COM 7  Elapse Time (MSec):  108608
Read from UUT:
Product Addr Product ID:  SW Ver Addi  SW Version:  CRC Addr:  CRC Value:
0x000000  0x3DC002  x00000094  0x3DC000  0x253C7DD2
Send command to UUT to compute its CRC value  0x25307DD2
Read from image file:
Product ID: 010000  SW Version:  h0094  CRC Value:  x253C7DD2
Select image file  CAG650_LOADER REULABEL_35 G650_ML_Flash_CRC.519
Flash Program Memory:  Start Addr:  1:003DC000  End Addr:  0x003E7FFF
Upload progress:
Status:
Flash progra
Quit
Figure 15
ML Post Upload with CRC Verification
(q) Click the "Yes" to confirm and exit the CL and ML windows.
UART CL_Upload  UART ML_ Upload
* Yes (Quit this prgram), or No (Continue this program) ?  * Yes (Quit this prgram), or No (Continue this program) ?
Yes  No  Yes  No
Figure 16
UART Field Programmer Exit Window
Initial Issue May 23, 2017  469000-27-003
Rev. 1 Oct 11, 2017  Page 17 of 23
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER-HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER USE
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.

### Page 20 (OCR)

Parker
Customer Support Operations
SERVICE BULLETIN
(г)  To upload the REU S/N, select "Upload REU Serial Number" option.
UART Field Loader Tool, Version 1.1.4, 03/20/2017
UART Reader:
Read REU CRC Values
Read MCE CRC Value
Read REU Serial Number
Download REU NVM Fault History
Download MCE NVM Fault History
- UART Loader:
UART Data Loader
Upload REU Serial Number
Parker Aerospace 2016 (C)  Quit
Figure 17
UART Field Loader Tool S/N Window
(s) The "Upload REU Serial Number" window will be displayed next.
• Upload REU Serial Number  00x
Serial Number 1  ....65535  Upload
CL Upload Status: Ready
ML Upload Status: Ready  Exit
Figure 18
Upload REU S/N Window
Initial Issue May 23, 2017  469000-27-003
Rev. 1 Oct 11, 2017  Page 18 of 23
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER-HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER USE
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED

### Page 21

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 19 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
(t) Enter the 4-digit S/N number (from REU nameplate) between 1 and 65535 and click 
“Upload”.  See Figure 27.   
  
Figure 19   
REU S/N Input   
(u) Verify that when CL and ML Upload Status changes from “Ready” to “Done”.  The 
completion status of S/N upload is reported in a pop-up window.   
 
Figure 20   
REU CL and ML S/N Successful Upload   
(v) Click the “OK” button in the “UART_FieldProgrammer” pop-up window.   
(w) Click the “Exit” button in the “Upload REU Serial Number” dialog window to return to the 
UART Field Loader Tool main menu.

### Page 22

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 20 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
(x) To read the REU S/N, go to Start > All Programs > UART_FieldProgrammer > 
UART_FieldProgrammer.exe” or click on the desktop UART icon to select “Read REU 
Serial Number” option.   
 
Figure 21   
Read REU S/N Window   
(y) Verify the “Read REU Serial Number” window displays the S/N entered in step 3.I.(1)(t) 
retrieved from Command Lane and Monitor Lane Non-Volatile Memory (NVM) locations.  
Make sure the two returned values are identical and match the S/N on the nameplate.  
Depending on the current NVM contents, the display will be similar to the window below:   
 
Figure 22  
CL and ML S/Ns Window

### Page 23

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 21 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
(z) Verify the completion status of S/N reading in the following pop-up window and click 
“OK”.   
 
Figure 23   
S/N Status Window   
(aa) If S/N does not match nameplate, repeat step (r) through (z).   
(bb) Click the “Exit” button in the “Read REU Serial Number” dialog window.   
(cc) Verify the UART Field Loader Tool is properly exited and closed.   
(dd) Power down the 28 VDC Power Supply from the external power source, unplug the 
banana plugs from the power source, and remove the Software Programming Cable 
469000TF65 which are connected to the REU and the Software Field Loader 
474000GSE1-2 and -3.   
J. REU Software Modification Label   
Upon completion of the software upload procedures as defined in the above paragraphs, the trained 
technician will update the Software Version label on the REU unit’s cover by permanently etching or 
engraving an X the previous revision number.  The lowest legible number on the label is the current 
software revision.  See Figure 24.   
 
Figure 24   
REU Software Revision Marking

### Page 24

Customer Support Operations 
 SERVICE BULLETIN  
 
Initial Issue May 23, 2017  469000-27-003 
Rev. 1 Oct 11, 2017  Page 22 of 23 
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER -HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE 
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT 
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER US E 
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.  
 
K. O-ring replacement  (On-bench only, and spare REUs)   
CAUTION:  MAKE SURE SEALING SURFACE HAS PROTECTION FROM DAMAGE WHEN O-
RING IS REMOVED.   
(1) Use a rounded, dull-edged nylon pick to remo ve disturbed O-ring P/N NAS1611-019A from REU 
J3 connector.   
(2) Check O-ring groove for distorti on, damage, burrs or corrosion before installing the new O-ring.   
(3) Install O-ring and make sure it is fully seated in the connector groove.  Do not apply lubricant.  
See Figure 25.   
 
 
Figure 25   
O-ring Installation   
CAUTION:  INSTALL ESD PROTECTIVE CAP ANYTIME THE REU IS NOT ATTACHED TO 
THE MANIFOLD.   
L. Cap installation  (On-bench)   
Make sure ESD protective caps are installed on connectors J1, J2 P/N 121021-31 and J3 P/N 
121021-27 to keep internal parts clean and to prevent damage during handling.   
NOTE:  Parker authorized technician(s) related tasks are complete upon performing steps above.  
Subsequent aircraft return to service activity will be performed by GAC per ASC-069.

### Page 25 (OCR)

barker
Customer Support Operations
SERVICE BULLETIN
4.  APPENDIX
REU  S/N LOCATION
J2
J3 LOCATED BOTTOM
OF REU
469000-27-003SB_RO Fig26
Figure 26
REU - Connector Locations
- NAMEPLATE
REMOTE ELECTRONICS UNIT  S/N LOCATION
GULFSTREAM P/N
PARKER P/N 469000-  | REY
MFG. DATE  SERIAL
INPUT: 28VDC
OUTPUT: 28V. 2A
Parke  INSPECTION
CAGE CODE 82106
CONTROL SYSTEMS DIVISION
FLIGHT CONTROL AND HYDRAULIC SYSTEMS
PARKER AEROSPACE GROUP, PARKER HANNIFIN CORP.
469000-27-003SB_RO Fig27
Figure 27
REU - S/N Location
Initial Issue May 23, 2017  469000-27-003
Rev. 1 Oct 11, 2017  Page 23 of 23
THIS DOCUMENT CONTAINS INFORMATION THAT IS CONFIDENTIAL AND PROPRIETARY TO PARKER-HANNIFIN CORPORATION. THIS DOCUMENT IS FURNISHED ON THE
UNDERSTANDING THAT THE DOCUMENT AND THE INFORMATION IT CONTAINS WILL NOT BE COPIED OR DISCLOSED TO OTHERS EXCEPT WITH THE WRITTEN CONSENT
OF PARKER, WILL NOT BE USED FOR ANY PURPOSE OTHER THAN CONDUCTING BUSINESS WITH PARKER, AND WILL BE RETURNED AND ALL FURTHER USE
DISCONTINUED UPON REQUEST BY PARKER. COPYRIGHT PARKER. YEAR OF COPYRIGHT IS FIRST YEAR INDICATED ON THIS DOCUMENT. ALL RIGHTS RESERVED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.