# Pratt & Whitney Service Bulletin PW4G-112-72-309

Copy: Revision 1 ("U.S. DOT/FAA - Service Bulletin - PW4G-112-72-309 R1"), 38 pages: PDF https://openairdocs.org/files/sha256/7b/65/7b65c2101f67689ac147444475c078570c5f182617a74334853ecb4cd236987d; text https://openairdocs.org/service-documents/pratt-whitney/pw4g-112-72-309/file/7b65c2101f67.md. Rights: © Pratt & Whitney. Filed by the FAA in regulations.gov docket FAA-2010-1095; AD 2011-14-07, 2012-13-02 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Pratt & Whitney](https://openairdocs.org/service-documents/pratt-whitney.md)
- Type: Service bulletin (Service Bulletin)
- Number: PW4G-112-72-309
- Latest revision known: PW4G-112-72-309, Revision 1, dated July 1, 2010 (OpenAirDocs)
- Page: https://openairdocs.org/service-documents/pratt-whitney/pw4g-112-72-309

## ADs that cite it (2) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2012-13-02](https://openairdocs.org/ad/2012-13-02.md), effective Aug 23, 2012: Revision 1
- [AD 2011-14-07](https://openairdocs.org/ad/2011-14-07.md), effective Sep 8, 2011: Revision 1

Also cited in [1 proposed AD](https://openairdocs.org/service-documents/pratt-whitney/pw4g-112-72-309/proposed.md).

## Text (38 pages)

Rights: © Pratt & Whitney. Filed by the FAA in regulations.gov docket FAA-2010-1095; AD 2011-14-07, 2012-13-02 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

SER
VICE
BULLETIN
REVISION
NOTICE
ENGINE
—
DISK,
15TH
ST
AGE
HIGH
PRESSURE
COMPRESSOR
(HPC)
—
REPETITIVE
BORESCOPE
INSPECTION
OR
EDDY
CURRENT
INSPECTION
(ECI)
FOR
CRACKS
IN
THE
FRONT
RAIL
OF
THE
OUTER
RIM
T
urbojet
Engine
Service
Bulletin
No.
PW4G-1
12-72-309
Revision
No.
1
dated
July
1,
2010.
R
e
v
i
s
i
o
n
H
i
s
t
o
r
y
Original
Issue
November
10,
2009
Revision
1
dated
July
1,
2010
R
e
a
s
o
n
f
o
r
t
h
e
R
e
v
i
s
i
o
n
T
o
update
the
number
of
cracks
found
in
service
engines
to
date
from
41
to
53.
T
o
revise
the
compliance
to
include
a
drawdown
plan
and
limit
disk
life
to
12,000
cycles.
T
o
attach
NDIP-1014,
Revision
B.
T
o
remove
“There
is
no
terminating
action
for
this
repetitive
inspection
at
this
time.”.
T
o
remove
“NOTE:
Engine
Serial
No.
P777032
and
P777038
were
inspected
and
meet
the
initial
inspection
requirement
of
this
Service
Bulletin”
from
the
Ef
fectivity
section.
E
f
f
e
c
t
o
f
R
e
v
i
s
i
o
n
o
n
P
r
i
o
r
C
o
m
p
l
i
a
n
c
e
None.
T
h
i
s
i
s
a
C
o
m
p
l
e
t
e
R
e
v
i
s
i
o
n
(
N
o
t
A
p
p
l
i
c
a
b
l
e
t
o
t
h
e
S
G
M
L
v
e
r
s
i
o
n
)
The
contents
are
in
accordance
with
the
list
of
ef
fective
pages.
All
pages
have
the
current
revision
number
.
T
echnical
changes
are
marked
with
black
bars.
N
o
n
-
D
e
s
t
r
u
c
t
i
v
e
I
n
s
p
e
c
t
i
o
n
P
r
o
c
e
d
u
r
e
s
NDIP-1014,
Revision
B
dated
June
7,
2010
is
attached.
Please
discard
the
previously
issued
copy
.
M
O
D
E
L
A
P
P
L
I
C
A
T
I
O
N
PW4074,
PW4077
B
U
L
L
E
T
I
N
I
S
S
U
E
S
E
Q
U
E
N
C
E
PW4G-1
12
Series
72-309
P
a
g
e
R
e
v
i
s
i
o
n
N
o
.
D
a
t
e
1
thru
18
1
July
1/10
A
copy
of
this
Revision
Notice
and
any
future
revision
notices
must
be
filed
as
a
permanent
record
with
your
copy
of
the
subject
bulletin.
P
&
W
D
i
s
t
r
i
b
u
t
i
o
n
C
o
d
e
2641,
2648
PW4G-1
12-72-309
Page
1
of
1
Printed
in
United
States
of
America

### Page 2

SER
VICE
BULLETIN
ENGINE
—
DISK,
15TH
ST
AGE
HIGH
PRESSURE
COMPRESSOR
(HPC)
—
REPETITIVE
BORESCOPE
INSPECTION
OR
EDDY
CURRENT
INSPECTION
(ECI)
FOR
CRACKS
IN
THE
FRONT
RAIL
OF
THE
OUTER
RIM
M
O
D
E
L
A
P
P
L
I
C
A
T
I
O
N
PW4074,
PW4077
B
U
L
L
E
T
I
N
I
S
S
U
E
S
E
Q
U
E
N
C
E
PW4G-1
12
Series
72-309
A
T
A
N
U
M
B
E
R
72-35-00
U
T
C
/
P
&
W
P
R
O
P
R
I
E
T
A
R
Y
I
N
F
O
R
M
A
T
I
O
N
This
document
is
the
property
of
United
T
echnologies
Corporation
—
Pratt
&
Whitney
(UTC/P&W).
Y
ou
may
not
possess,
use,
copy
or
disclose
this
document
or
any
information
in
it,
for
any
purpose,
including
without
limitation
to
design,
manufacture,
or
repair
parts,
or
obtain
F
AA
or
other
government
approval
to
do
so,
without
UTC/P&W’
s
express
written
permission.
Neither
receipt
nor
possession
of
this
document
alone,
from
any
source,
constitutes
such
permission.
Possession,
use,
copying
or
disclosure
by
anyone
without
UTC/P&W’
s
express
written
permission
is
not
authorized
and
may
result
in
criminal
and/or
civil
liability
.
C
o
m
p
l
i
a
n
c
e
C
a
t
e
g
o
r
y
3
P
&
W
D
i
s
t
r
i
b
u
t
i
o
n
C
o
d
e
2641,
2648
l
November
10/09
PW4G-1
12-72-309
REVISION
NO.
1
-
July
1/10
Page
1
of
18
Printed
in
United
States
of
America

### Page 3

S
u
m
m
a
r
y
The
purpose
of
this
Service
Bulletin
is
to
provide
instructions
to
do
a
repetitive
borescope
inspection
or
Eddy
Current
Inspection
(ECI)
of
the
15th
stage
High
Pressure
Compressor
(HPC)
disk
for
cracks.
Inspection
of
15th
stage
disks
of
in
service
engines
found
53
cracks
in
the
front
rail
of
the
blade
loading
and/or
locking
slots
on
the
outer
rim.
Metallurgical
examination
of
the
15th
stage
HPC
disk
cracks
revealed
that
the
initiation
was
the
result
of
Thermal
Mechanical
Fatigue
(TMF).
Remove
from
service
any
disk
that
has
a
crack.
The
ECI
is
in
NDIP-1014
Revision
B
and
is
provided
in
the
Appendix
section
of
this
Service
Bulletin.
P
l
a
n
n
i
n
g
I
n
f
o
r
m
a
t
i
o
n
E
f
f
e
c
t
i
v
i
t
y
D
a
t
a
E
n
g
i
n
e
M
o
d
e
l
s
A
p
p
l
i
c
a
b
l
e
PW4074,
PW4077
Engine
Serial
No.
—
All
engines
that
have
15th
Stage
HPC
Disk,
PN
55H615
installed.
C
o
n
c
u
r
r
e
n
t
R
e
q
u
i
r
e
m
e
n
t
s
There
are
no
concurrent
requirements.
R
e
a
s
o
n
1.
Problem:
Inspection
of
15th
stage
disks
of
in
service
engines
found
53
cracks
in
the
front
rail
of
the
blade
loading
and/or
locking
slots
on
the
outer
rim.
2.
Cause:
Metallurgical
examination
of
the
cracks
revealed
that
the
initiation
was
the
result
of
TMF
.
3.
Solution:
Do
a
repetitive
borescope
inspection
or
ECI
of
the
15th
stage
HPC
disk.
D
e
s
c
r
i
p
t
i
o
n
Do
a
borescope
inspection
or
ECI
of
the
15th
stage
HPC
disk.
C
o
m
p
l
i
a
n
c
e
Category
3
15th
stage
HPC
Disks,
PN
55H615
with
12,000
part
cycles
since
new
must
be
removed
from
service.
For
engines
with
disks
that
have
accumulated
less
than
or
equal
to
9,865
cycles
when
this
Service
Bulletin
is
released,
the
engine
must
be
removed
when
the
15th
disk
accumulates
12,000
cycles
since
new
.
For
engines
with
disks
that
have
accumulated
more
than
9,865
cycles
when
this
Service
Bulletin
is
released,
the
engine
must
be
removed
by
2,135
cycles
after
Service
Bulletin
release.
If
a
disk
exceeds
12,000
cycles
since
new
before
the
engine
is
removed,
perform
an
inspection
of
the
disk
before
12,000
cycles,
and
repeat
the
inspection
before
1,200
additional
cycles
until
the
disk
is
removed
within
2,135
cycles,
or
a
crack
is
found.
The
repeat
inspection
is
waived
if
the
previous
inspection
was
accomplished
with
ECI.
N
O
T
E
:
FPI
can
be
done
as
specified
in
Reference
4,
CIR
Manual,
Chapter/Section
72-35-92,
Inspection/Check-02
or
Reference
6,
Service
Bulletin
No.
PW4G-1
12-72-243.
ECI
can
be
done
as
specified
in
Reference
7,
NDIP-1014
Revision
B
.
NDIP-1014
Revision
B
is
provided
in
the
Appendix
section
of
this
Service
Bulletin.
l
November
10/09
PW4G-1
12-72-309
REVISION
NO.
1
-
July
1/10
Page
2
UTC/P&W
PROPRIET
AR
Y
INFORMA
TION
Subject
to
the
restrictions
on
the
cover
or
first
page.

### Page 4

If
a
crack
is
suspected
by
borescope
inspection,
but
cannot
be
visually
confirmed,
do
an
ECI
within
5
cycles.
A
p
p
r
o
v
a
l
D
a
t
a
The
times
between
inspections
specified
in
Compliance
and
the
inspection
procedures
specified
in
the
Accomplishment
Instructions
agree
with
the
applicable
Federal
A
viation
Regulations
and
are
F
AA-Approved
for
the
engine
model(s)
given.
M
a
n
p
o
w
e
r
The
estimate
of
man-hours
of
labor
directly
necessary
to
do
the
intent
of
this
Service
Bulletin
are
as
follows:
F
o
r
E
n
g
i
n
e
s
I
n
s
t
a
l
l
e
d
O
n
T
h
e
A
i
r
c
r
a
f
t
1.
Open
and
Close
Cowl
Doors
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
0.5
2.
Necessary
to
do
the
Inspection
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
2.5
3.
T
otal
Necessary
Man-hours
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3.0
F
o
r
E
n
g
i
n
e
s
R
e
m
o
v
e
d
F
r
o
m
T
h
e
A
i
r
c
r
a
f
t
1.
Necessary
to
do
the
Inspection
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
2.5
2.
T
otal
Necessary
Man-hours
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
2.5
W
e
i
g
h
t
D
a
t
a
No
Change.
E
l
e
c
t
r
i
c
a
l
L
o
a
d
D
a
t
a
Not
Applicable.
S
o
f
t
w
a
r
e
A
c
c
o
m
p
l
i
s
h
m
e
n
t
S
u
m
m
a
r
y
Not
Applicable.
R
e
f
e
r
e
n
c
e
s
1.
T
urbojet
Engine
Standard
Practices
Manual,
Part
No.
585005.
2.
PW4074,
PW4077
T
urbofan
Engines,
Illustrated
Parts
Catalog,
Part
No.
51A346.
3.
PW4074,
PW4077
T
urbofan
Engines,
Engine
Manual,
Part
No.
51A345.
4.
PW4000
Series
1
12
Inch
PW4074,
PW4077,
PW4077D,
PW4084D,
PW4090,
PW4098
T
urbofan
Engines,
Engine
Cleaning,
Inspection
And
Repair
(CIR)
Manual,
Part
No.
51A750.
5.
Boeing
777
Aircraft
Maintenance
Manual.
6.
Service
Bulletin
No.
PW4G-1
12-72-243;
Engine
—
Disk,
15Th
Stage
High
Pressure
Compressor
(HPC)
—
Inspection
For
Cracks
In
The
Blade
Slot
Loading
And
Locking
Locations
And
Knife
Edge
Seal
Location.
Issue
Sequence
72-243,
PW4G-1
12
Series.
7.
Non-Destructive
Inspection
Procedure
NDIP-1014,
Revision
B
,
—
PW4074
/
PW4077
15th
Stage
HPC
Disk
Front
Rail
Blade
Loading
Slot
and
Locking
Areas
Eddy
Current
Inspections
(Assembled/Aircraft
Installed).
l
November
10/09
PW4G-1
12-72-309
REVISION
NO.
1
-
July
1/10
Page
3
UTC/P&W
PROPRIET
AR
Y
INFORMA
TION
Subject
to
the
restrictions
on
the
cover
or
first
page.

### Page 5

P
u
b
l
i
c
a
t
i
o
n
s
C
h
a
n
g
e
d
Not
Applicable.
I
n
t
e
r
c
h
a
n
g
e
a
b
i
l
i
t
y
Not
Applicable.
I
n
f
o
r
m
a
t
i
o
n
i
n
t
h
e
A
p
p
e
n
d
i
x
Alternate
Accomplishment
Instructions
(No)
Progression
Charts
(No)
Added
Data
(Y
es)
Revision
to
T
able
of
Limits
(No)
Inspection
Procedures
(No)
l
November
10/09
PW4G-1
12-72-309
REVISION
NO.
1
-
July
1/10
Page
4
UTC/P&W
PROPRIET
AR
Y
INFORMA
TION
Subject
to
the
restrictions
on
the
cover
or
first
page.

### Page 6

M
a
t
e
r
i
a
l
I
n
f
o
r
m
a
t
i
o
n
M
a
t
e
r
i
a
l
—
C
o
s
t
a
n
d
A
v
a
i
l
a
b
i
l
i
t
y
1.
The
estimated
price
to
do
the
Borescope
Inspection
procedure
in
this
Service
Bulletin
is
$12.90
for
a
new
borescope
plug
key
washer
.
2.
There
is
no
kit
provided
to
do
this
Service
Bulletin.
3.
Part
availability
information
is
provided
in
material
data
Instructions
—
Disposition.
I
n
d
u
s
t
r
y
S
u
p
p
o
r
t
P
r
o
g
r
a
m
Not
Applicable.
T
h
e
m
a
t
e
r
i
a
l
d
a
t
a
t
h
a
t
f
o
l
l
o
w
s
i
s
f
o
r
e
a
c
h
e
n
g
i
n
e
.
N
O
T
E
:
It
is
possible
to
use
the
Chapter/Section
and
Figure/Item
reference
number
shown
below
the
old
part
number
to
find
the
part
in
the
Illustrated
Parts
Catalog.
C
A
U
T
I
O
N
:
THE
FOLLOWING
MA
TERIAL
DA
T
A
T
ABLE(S)
ARE
ORGANIZED
BY
ILLUSTRA
TED
P
AR
TS
CA
T
ALOG.
ALL
P
AR
TS
IN
THE
T
ABLE(S)
MA
Y
OR
MA
Y
NOT
BE
APPLICABLE
T
O
ALL
THE
ENGINE
MODELS
SHOWN
IN
THE
T
ABLE
HEADING.
YOU
MUST
REFER
T
O
THE
APPROPRIA
TE
ILLUSTRA
TED
P
AR
TS
CA
T
ALOG
FOR
ENGINE
MODEL
APPLICABILITY
USING
THE
OLD
P
AR
T
NUMBER
(PN)
AND
CA
T
ALOG
SEQUENCE
NUMBER.
F
AILURE
T
O
INST
ALL
THE
P
AR
T(S)
IN
THE
CORRECT
ENGINE
MODEL
MA
Y
RESUL
T
IN
A
CONFIGURA
TION
THA
T
IS
NOT
F
AA
APPROVED.
T
h
e
m
a
t
e
r
i
a
l
d
a
t
a
t
h
a
t
f
o
l
l
o
w
s
i
s
f
o
r
e
a
c
h
e
n
g
i
n
e
.
F
o
r
P
W
4
0
7
4
,
P
W
4
0
7
7
E
n
g
i
n
e
s
:
New
PN
Qty
Estimate
of
Unit
Price
($)
Keyword
Old
PN
Instructions
—
Disposition
1
DISK
—
HPC,
15STG
55H615
(72-35-00-1-210)
(4)(X)
58H216
1
12.90
KEY
W
ASHER
58H216
(72-35-00-25-20
A)
(E)
M
o
d
i
fi
c
a
t
i
o
n
a
n
d
S
p
a
r
e
s
I
n
f
o
r
m
a
t
i
o
n
Estimated
part
prices
are
provided
when
they
are
available
at
time
of
publication.
The
Estimate
of
Unit
Price
is
only
for
planning
purposes
and
does
not
constitute
a
firm
quotation.
An
asterisk
(*)
is
shown
where
part
pricing
information
was
unavailable.
In
either
case,
contact
Pratt
&
Whitney
Spares
Management
&
Logistics
for
firm
quotations.
Parts
Modification
Conditions
(4)
Do
an
inspection
as
specified
in
the
Accomplishment
Instructions.
Spare
Parts
A
vailability
(E)
The
part
is
an
expendable
item
necessary
to
do
this
bulletin.
(X)
See
Reference
2,
Illustrated
Parts
Catalog
for
applicable
replacement
parts.
Cleaning,
Inspection
and
Repair
Information
Not
Applicable.
l
November
10/09
PW4G-1
12-72-309
REVISION
NO.
1
-
July
1/10
Page
5
UTC/P&W
PROPRIET
AR
Y
INFORMA
TION
Subject
to
the
restrictions
on
the
cover
or
first
page.

### Page 7

V
endor
Services
or
Special
Components/Materials
Not
Applicable.
M
a
t
e
r
i
a
l
D
a
t
a
f
o
r
E
a
c
h
S
p
a
r
e
E
n
g
i
n
e
The
material
for
each
spare
engine
is
as
stated
in
the
preceding
material
information
section.
R
e
i
d
e
n
t
i
fi
e
d
P
a
r
t
s
Not
Applicable.
N
e
c
e
s
s
a
r
y
T
o
o
l
s
N
e
w
S
u
p
p
o
r
t
E
q
u
i
p
m
e
n
t
t
h
a
t
i
s
n
e
c
e
s
s
a
r
y
T
ool
No.
Name
Standard
Flexible
borescope
with
articulating
tip
and
150
watt
minimum
light
source.
(A
4mm
flexible
borescope
is
recommended;
however
,
other
size
flexible
borescopes
can
be
used
if
the
viewing
quality
is
the
same
or
better
than
a
4mm
flexible
borescope.)
PW
A
88247
Rotator
(Or
equivalent
as
specified
in
Reference
5,
Aircraft
Maintenance
Manual)
O
t
h
e
r
M
a
t
e
r
i
a
l
I
n
f
o
r
m
a
t
i
o
n
D
a
t
a
Not
Applicable.
l
November
10/09
PW4G-1
12-72-309
REVISION
NO.
1
-
July
1/10
Page
6
UTC/P&W
PROPRIET
AR
Y
INFORMA
TION
Subject
to
the
restrictions
on
the
cover
or
first
page.

### Page 8

A
c
c
o
m
p
l
i
s
h
m
e
n
t
I
n
s
t
r
u
c
t
i
o
n
s
N
O
T
E
:
Service
Bulletin
incorporation
on
engines
installed
on
aircraft
may
be
desirable
and
should
be
individually
evaluated.
F
O
R
E
N
G
I
N
E
S
I
N
S
T
A
L
L
E
D
O
N
T
H
E
A
I
R
C
R
A
F
T
1.
Do
an
inspection
of
the
15th
Stage
Disk,
PN
55H615
by
one
of
the
procedures
that
follow
.
See
Figure
1.
A.
Do
an
ECI
of
the
disk
as
specified
in
Reference
7,
NDIP-1014
Revision
B
.
NDIP-1014
Revision
B
is
provided
in
the
Appendix
section
of
this
Service
Bulletin.
Or
B.
Do
a
borescope
inspection
of
the
disk
as
follows:
(1)
Open
fan
cowl
doors
and
thrust
reversers
as
specified
in
Reference
5,
Aircraft
Maintenance
Manual,
Chapter/Section
71-1
1-04
and
78-31-00.
N
O
T
E
:
The
variable
vanes
must
be
fully
open
when
the
engine
is
shutdown.
If
the
vanes
are
not
open
use
a
large
wrench
or
a
crows
foot
wrench
to
rotate
the
bellcrank
on
the
stator
vane
actuator
to
the
fully
open
position.
(2)
Access
the
disk
through
the
AP-7
(borescope)
port
as
specified
in
the
Reference
5,
Aircraft
Maintenance
Manual,
Chapter/Section
72-00-00.
See
Figure
2,
Sheets
1
and
2.
(3)
Insert
the
borescope
into
the
AP-7
port
to
view
the
front
rail
of
the
disk.
See
Figure
2,
Sheets
3
and
4.
(4)
Remove
the
gearbox
crank
pad
cover
and
use
a
PW
A
88247
Rotator
or
equivalent
to
rotate
the
rotor
at
the
gearbox
crank
pad.
(5)
Rotate
the
rotor
until
the
first
blade
lock
is
seen.
Use
the
blade
lock
locations
for
angular
reference.
See
Figure
3.
(6)
Rotate
the
rotor
in
the
same
direction
past
two
additional
blades.
If
another
blade
lock
is
found
just
past
the
second
blade
then
the
current
location
is
a
lock
and
loading
location.
The
loading
slot
(which
is
not
visible)
is
between
the
two
blade
locks.
See
Figure
3.
(7)
Do
an
inspection
of
the
front
rail
in
the
areas
adjacent
to
the
locking
slots
and
the
area
between
the
two
locking
slots
for
cracks.
Cracks
typically
run
in
the
radially
inboard
direction
from
the
outer
rim
of
the
rail.
See
Figure
2,
Sheet
4.
(8)
If
another
blade
lock
is
not
found
just
past
the
second
blade,
then
the
present
location
is
a
blade
lock
only
.
See
Figure
3.
(9)
Do
an
inspection
of
the
front
rail
for
cracks
adjacent
to
the
blade
lock.
Cracks
typically
run
in
the
radially
inboard
direction
from
the
outer
rim
of
the
rail.
See
Figure
2,
Sheet
4.
(10)
Rotate
the
rotor
until
the
next
blade
lock
is
visible
and
do
the
inspection
of
the
two
blade
lock
and
loading
areas
and
four
blade
lock
areas.
N
O
T
E
:
Rotating
the
crack
pad
360
degrees
represents
more
than
360
degrees
of
rotor
rotation.
(1
1)
The
inspection
criteria
is
as
follows:
l
November
10/09
PW4G-1
12-72-309
REVISION
NO.
1
-
July
1/10
Page
7
UTC/P&W
PROPRIET
AR
Y
INFORMA
TION
Subject
to
the
restrictions
on
the
cover
or
first
page.

### Page 9

(a)
If
the
disk
does
not
have
a
crack,
the
disk
is
acceptable.
(b)
If
the
disk
does
have
a
crack,
replace
the
disk.
(c)
If
a
crack
is
suspected,
but
cannot
be
visually
confirmed,
do
an
ECI
within
5
cycles,
as
specified
in
Reference
7,
NDIP-1014
Revision
B
.
NDIP-1014
Revision
B
is
provided
in
the
Appendix
section
of
this
Service
Bulletin.
(12)
Remove
the
borescope
and
install
the
AP-7
borescope
plug
and
new
Key
W
asher
,
PN
58H216
as
specified
in
Reference
5,
Aircraft
Maintenance
Manual,
Chapter/Section
72-00-00.
(13)
Remove
the
PW
A
88247
Rotator
or
equivalent
and
install
the
gearbox
crank
pad
cover
.
(14)
Close
fan
cowl
doors
and
thrust
reversers
as
specified
in
Reference
5,
Aircraft
Maintenance
Manual,
Chapter/Section
71-1
1-04
and
78-31-00.
(15)
Record
the
inspection
results.
For
all
disks
that
have
cracks:
operators
are
requested
to
provide
the
results
of
the
inspection
to
their
local
Pratt
&
Whitney
service
representative.
See
Figure
4
for
the
data
retrieval
form.
F
O
R
E
N
G
I
N
E
S
R
E
M
O
V
E
D
F
R
O
M
T
H
E
A
I
R
C
R
A
F
T
(
A
S
S
E
M
B
L
E
D
E
N
G
I
N
E
S
A
N
D
/
O
R
H
P
C
M
O
D
U
L
E
S
N
O
T
S
C
H
E
D
U
L
E
D
F
O
R
D
I
S
A
S
S
E
M
B
L
Y
O
R
I
N
S
P
E
C
T
I
O
N
)
1.
Do
an
inspection
of
the
15th
stage
disk,
PN
55H615
by
one
of
the
procedures
that
follow
.
See
Figure
1.
N
O
T
E
:
This
inspection
does
not
supersede
or
replace
Reference
6,
Service
Bulletin
No.
PW4G-1
12-72-243.
This
procedure
is
intended
for
assembled
engines
and/or
HPC
modules
not
scheduled
for
disassembly
or
inspection
as
specified
by
Reference
4,
CIR
Manual,
Chapter/Section
72-35-92,
Inspection/Check-02
or
Reference
6,
Service
Bulletin
No.
PW4G-1
12-72-243.
A.
Do
an
ECI
of
the
disk
as
specified
in
Reference
7,
NDIP-1014,
Revision
B
.
NDIP-1014,
Revision
B
is
provided
in
the
Appendix
section
of
this
Service
Bulletin.
or
B.
Do
a
borescope
inspection
of
the
disk
as
follows:
(1)
Access
the
disk
through
the
AP-7
(borescope)
port
as
specified
in
the
Reference
3,
Engine
Manual,
Chapter/Section
72-00-00,
Inspection/Check-03.
See
Figure
2,
Sheets
1
and
2.
N
O
T
E
:
The
variable
vanes
must
be
fully
open
when
the
engine
is
shutdown.
If
the
vanes
are
not
open
use
a
large
wrench
or
a
crows
foot
wrench
to
rotate
the
bellcrank
on
the
stator
vane
actuator
to
the
fully
open
position.
(2)
Insert
the
borescope
into
the
AP-7
port
to
view
the
front
rail
of
the
disk.
See
Figure
2,
Sheets
3
and
4.
(3)
Remove
the
gearbox
crank
pad
cover
and
use
a
PW
A
88247
Rotator
or
equivalent
to
rotate
the
rotor
at
the
gearbox
crank
pad.
(4)
Rotate
the
rotor
until
the
first
blade
lock
is
seen.
Use
the
blade
lock
locations
for
angular
reference.
See
Figure
3.
(5)
Rotate
the
rotor
in
the
same
direction
past
two
additional
blades.
If
another
blade
lock
is
found
just
past
the
second
blade
then
the
current
location
is
a
l
November
10/09
PW4G-1
12-72-309
REVISION
NO.
1
-
July
1/10
Page
8
UTC/P&W
PROPRIET
AR
Y
INFORMA
TION
Subject
to
the
restrictions
on
the
cover
or
first
page.

### Page 10

lock
and
loading
location.
The
loading
slot
(which
is
not
visible)
is
between
the
two
blade
locks.
See
Figure
3.
(6)
Do
an
inspection
of
the
front
rail
in
the
areas
adjacent
to
the
locking
slots
and
the
area
between
the
two
locking
slots
for
cracks.
Cracks
typically
run
in
the
radially
inboard
direction
from
the
outer
rim
of
the
rail.
See
Figure
2,
Sheet
4.
(7)
If
another
blade
lock
is
not
found
just
past
the
second
blade,
then
the
location
is
a
blade
lock
only
.
See
Figure
3.
(8)
Do
an
inspection
of
the
front
rail
for
cracks
adjacent
to
the
blade
lock.
Cracks
typically
run
in
the
radially
inboard
direction
from
the
outer
rim
of
the
rail.
See
Figure
2,
Sheet
4.
(9)
Rotate
the
rotor
until
the
next
blade
lock
is
visible
and
do
the
inspection
of
the
two
blade
lock
and
loading
areas
and
four
blade
lock
areas.
N
O
T
E
:
Rotating
the
crack
pad
360
degrees
represents
more
than
360
degrees
of
rotor
rotation.
(10)
The
inspection
criteria
is
as
follows:
(a)
If
the
disk
does
not
have
a
crack,
the
disk
is
acceptable.
(b)
If
the
disk
does
have
a
crack,
replace
the
disk.
(c)
If
a
crack
is
suspected,
but
cannot
be
visually
confirmed,
do
an
ECI
within
5
cycles,
as
specified
in
Reference
7,
NDIP-1014
Revision
B
.
NDIP-1014
Revision
B
is
provided
in
the
Appendix
section
of
this
Service
Bulletin.
(1
1)
Remove
the
borescope
and
install
the
AP-7
borescope
plug
and
new
Key
W
asher
,
PN
58H216
as
specified
in
Reference
3,
Engine
Manual,
Chapter/Section
72-00-00,
Inspection/Check-03.
(12)
Remove
the
PW
A
88247
Rotator
or
equivalent
and
install
the
gearbox
crank
pad
cover
.
(13)
Record
the
inspection
results.
For
all
disks
that
have
cracks:
operators
are
requested
to
provide
the
results
of
the
inspection
to
their
local
Pratt
&
Whitney
service
representative.
See
Figure
4
for
the
data
retrieval
form.
l
November
10/09
PW4G-1
12-72-309
REVISION
NO.
1
-
July
1/10
Page
9
UTC/P&W
PROPRIET
AR
Y
INFORMA
TION
Subject
to
the
restrictions
on
the
cover
or
first
page.

### Page 11 (OCR)

Pratt & Whitney
A United Technologies Company
55H615
15TH STAGE DISK
INSPECT AS SPECIFIED IN
THE ACCOMPLISHMENT
INSTRUCTIONS
B521581
LOCATION OF THE 15TH STAGE HPC DISK
72-35-00
FIGURE 1
November 10/09  PW4G-112-72-309
• REVISION NO. 1 - July 1/10  Page 10
UTC/P&W PROPRIETARY INFORMATION
Subject to the restrictions on the cover or first page.

### Page 12 (OCR)

Pratt & Whitney
A United Technologies Company
RIGHT SIDE OF ENGINE
— 80°
(AP-7)
REAR SCHEMATIC VIEW
LOCATION OF THE AP-7 PORT
B521582
INSPECTION OF THE 15TH STAGE HPC DISK
FIGURE 2, SHEET 1
November 10/09  PW4G-112-72-309
REVISION NO. 1 - July 1/10  Page 11
UTC/P&W PROPRIETARY INFORMATION
Subject to the restrictions on the cover or first page.

### Page 13 (OCR)

Pratt & Whitney
A United Technologies Company
- WI
AP-7 PLUG  58H216
KEY WASHER
VIEW A
LOCATION OF THE AP-7 PORT
B521583
INSPECTION OF THE 15TH STAGE HPC DISK
FIGURE 2, SHEET 2
November 10/09  PW4G-112-72-309
• REVISION NO. 1 - July 1/10  Page 12
UTC/P&W PROPRIETARY INFORMATION
Subject to the restrictions on the cover or first page.

### Page 14 (OCR)

Pratt & Whitney
A United Technologies Company
AP-7
BORESCOPE ACCESS
COMPRESSOR
EXIT STATOR
(STAGE 15)
BLADE  STAGE 15  STAGE 14  BLADE
STAGE 14  STAGE 13
STATOR  STATOR
ENGINE
CENTER LINE
BORESCOPE INSPECTION PATH, FRONT RAIL
VIEW B-B
B521584
INSPECTION OF THE 15TH STAGE HPC DISK
FIGURE 2, SHEET 3
November 10/09  PW4G-112-72-309
• REVISION NO. 1 - July 1/10  Page 13
UTC/P&W PROPRIETARY INFORMATION
Subject to the restrictions on the cover or first page.

### Page 15 (OCR)

Pratt & Whitney
A United Technologies Company
- WD
• FRONT RAIL
POSITION BORESCOPE
FOR INSPECTION
IN THIS AREA
SECTION C-C
15TH STAGE DISK
B521585
INSPECTION OF THE 15TH STAGE HPC DISK
FIGURE 2, SHEET 4
November 10/09  PW4G-112-72-309
| REVISION NO. 1 - July 1/10  Page 14
UTC/P&W PROPRIETARY INFORMATION
Subject to the restrictions on the cover or first page.

### Page 16 (OCR)

Pratt & Whitney
A United Technologies Company
BLADE LOCK 1  BLADE LOCK 2
BLADE LOCK 8  BLADE LOCK 3
BLADE LOADING
SLOT AREAS
BLADE LOCK 7  BLADE LOCK 4
BLADE LOCK 6  BLADE LOCK 5
BLADE
LOCK
15TH STAGE
HPC BLADES
BLADE LOADING
SLOT AREAS  BLADE
LOCK
B521588
TYPICAL VIEW OF BLADE LOADING SLOT AREAS
FIGURE 3
November 10/09  PW4G-112-72-309
• REVISION NO. 1 - July 1/10  Page 15
UTC/P&W PROPRIETARY INFORMATION
Subject to the restrictions on the cover or first page.

### Page 17 (OCR)

Pratt & Whitney
A United Technologies Company
ENGINE INFORMATION
OPERATOR
ENGINE MODEL
ENGINE SERIAL NUMBER
DISK SERIAL NUMBER -
DISK CYCLES SINCE NEW (TC)
DISK TIME SINCE NEW (TT)
DISK CYCLES SINCE LAST INSPECTION (CSLI) -
DISK TIME SINCE LAST INSPECTION (TSLI)
CRACK LENGTH
NUMBER OF CRACKS -
DISCRIPTION OF FINDING / INDICATION
B521587
DATA RETRIEVAL FORM
FIGURE 4
I REVISION NO. 1 - July 1/10  November 10/09  PW4G-112-72-309  Page 16
UTC/P&W PROPRIETARY INFORMATION
Subject to the restrictions on the cover or first page.

### Page 18

A
p
p
e
n
d
i
x
A
d
d
e
d
D
a
t
a
I
n
t
e
r
n
a
l
R
e
f
e
r
e
n
c
e
I
n
f
o
r
m
a
t
i
o
n
Revision
No.
Reference
Document
Origination
Original
EA09KA050
EA09KCC43
DB/IEL
1
EA09KCC43
DB/JEJ
Non-Destructive
Inspection
Procedure
NDIP-1014,
Revision
B
follows:
l
November
10/09
PW4G-1
12-72-309
REVISION
NO.
1
-
July
1/10
Page
17
UTC/P&W
PROPRIET
AR
Y
INFORMA
TION
Subject
to
the
restrictions
on
the
cover
or
first
page.

### Page 19

NDIP-1014 REV. B Effective 06/07/2010 
 
 1
PW4074 / PW4077 
15th Stage HPC Disk 
Front Rail Blade Loading Slot and Locking Areas 
Eddy Current Inspections  
(Assembled/Aircraft Installed)  
 
 
NDIP–1014 
REVISION B 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
WARNING 
THIS DOCUMENT MAY CONTAIN INFORMATION SUBJECT TO THE INTERNATIONAL TRAFFIC IN ARMS REGULATION (ITAR) OR THE EXPORT 
ADMINISTRATION REGULATION (EAR) OF 1979. THIS INFORMATION MAY NOT BE EXPORTED, RELEASED, OR DISCLOSED TO FOREIGN 
NATIONALS OUTSIDE THE UNITED STATES WITHOUT FIRST COMPLYING WITH THE EXPORT LICENSE REQUIREMENTS OF THE 
INTERNATIONAL TRAFFIC IN ARMS REGULATION (ITAR) AND/OR THE EXPORT ADMINISTRATION REGULATION (EAR). A VIOLATION OF THE 
ITAR OR EAR MAY BE SUBJECT TO A PENALTY OF UP TO 10 YEARS IMPRISONMENT AND A FINE OF $1,000,000 UNDER 22 U.S.C 2778 OR 
SECTION 2410 OF THE EXPORT ADMINISTRATION ACT OF 1979. INCLUDE THIS NOTICE WITH ANY REPRODUCED PORTION OF THIS 
DOCUMENT. 
 
RESTRICTION 
PAGES OF THIS DOCUMENT MARKED WITH THE NOTICES SET FORTH BELOW CONTAIN CONTRACTOR COMPETITION SENSITIVE DATA 
AND/OR PRATT & WHITNEY PROPRIETARY DATA WHICH IS SUBMITTED IN CONFIDENCE. NO DISCLOSURE OR USE OF THIS INFORMATION 
IS PERMISSIBLE WITHOUT PRIOR WRITTEN CONSENT OF UNITED TECHNOLOGIES CORPORATION EXCEPT FOR OFFICIAL PURPOSES 
WITHIN THE U.S. GOVERNMENT. 
 
DOCUMENT PROPERTY RIGHTS NOTICE 
THIS DOCUMENT IS THE PROPERTY OF UNITED TECHNOLOGIES CORPORATION (UTC).  YOU MAY NOT POSSESS, USE, COPY OR 
DISCLOSE THIS DOCUMENT OR ANY INFORMATION IN IT, FOR ANY PURPOSE, INCLUDING WITHOUT LIMITATION TO DESIGN, 
MANUFACTURE OR REPAIR PARTS, OR OBTAIN FAA OR OTHER GOVERNMENT APPROVAL TO DO SO, WITHOUT UTC’S EXPRESS WRITTEN 
PERMISSION.  NEITHER RECEIPT NOR POSSESSION OF THIS DOCUMENT ALONE, FROM ANY SOURCE, CONSTITUTES SUCH PERMISSION.  
POSSESSION, USE, COPYRIGHT OR DISCLOSURE BY ANYONE WITHOUT UTC’S EXPRESS WRITTEN PERMISSION IS NOT AUTHORIZED AND 
MAY RESULT IN CRIMINAL AND OR CIVIL LIABILITY. 
 
NOTICES 
P&W PROPRIETARY INFORMATION       ECCN 9E991 - EXPORT CONTROLLED

### Page 20

NDIP-1014 REV. B Effective 06/07/2010 
 
 
 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
2
PW4074 / PW4077 
15th Stage HPC Disk 
Front Rail Blade Loading Slot and Locking Areas  
Eddy Current Inspections  
(Assembled/Aircraft Installed) 
 
 
NDIP–1014 Revision B 
 
 
 
Issue Date: June 07, 2010 
 
Written By: Wenji Peng 
 
Approved By: Jonathan Sullivan PL3 
 
 
 
 
Instructions described within this procedure do not replace, amend or supersede any instructions 
included in other Pratt & Whitney technical publications.  Active Service Bulletins and other 
technical publications published by Pratt & Whitney comprise approved technical data. 
 
 
The purpose of Revision A: 1. Apply this procedure only to engine models PW4074 / PW4077. 2. 
Add the requirements of eddy current inspections on all blade loading and locking areas of 15th 
stage HPC disk front rail. 
 
The purpose of revision B: Remove Figure 4, in which the AP7 and gear box locations have 
already been depicted and described in page 11-13 of the revision of Service Bulletins PW4G-112-
72-309, from NDIP-1014 A.

### Page 21

NDIP-1014 REV. B Effective 06/07/2010 
 
 
 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
3
PW4074 / PW4077 
15th Stage HPC Disk 
Front Rail Blade Loading Slot and Blade Locking Areas 
Eddy Current Inspections  
(Assembled/Aircraft Installed) 
I. GENERAL 
The objective of this eddy current inspection is to  verify crack indications in the front rail at 
the blade loading slot or blad e locking areas of the 15th st age high pressure compressor 
(HPC) disk for the PW4074/PW4077 engine models. The inspection is conducted on 
assembled engines and may be applied to an airc raft installed engine. 
The inspection is accomplished by inserting and manipulating an eddy current probe 
assembly through the AP-7 borescope access port to place the probe tip in contact with the 
front rail, and then rotating the HPC rotor to traverse the blade loading slot or blade 
locking area(s) past the probe. A borescope is in the AP-7 borescope access port alongside 
the probe assembly to visually aid in the placement of the eddy current probe and 
verification of proper probe position during inspection. 
This manual is provided as an inspection training guide.

### Page 22

NDIP-1014 REV. B Effective 06/07/2010 
 
II. ACCOMPLISHMENT INSTRUCTIONS  
      A.   EQUIPMENT REQUIRED, Figure 1.
 
 
 
FIGURE 1 
EQUIPMENT REQUIRED 
4 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document

### Page 23

NDIP-1014 REV. B Effective 06/07/2010 
 
1. PWA 105249, Eddy Current Probe Assembly, Figure 2. 
 
FIGURE 2 
PWA 105249 EDDY CURRENT PROBE ASSEMBLY 
NOTE: The PWA 105249 eddy current probe assembly consists of an absolute 
coil at the tip of a shaft attached to a handle with the electrical cables 
located within the shaft. 
 
 
 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
5

### Page 24

NDIP-1014 REV. B Effective 06/07/2010 
2. PWA 26964 Sensitivity Setting Standard, Figure 3. 
 
FIGURE 3 
PWA 26964 SENSITIVITY SETTING STANDARD 
NOTE: The PWA 26964 sensitivity setting standard consists a flat plate with a 
simulated defect, 0.750 inch (19.1 mm) long by 0.025 inch (0.64 mm) 
deep by 0.010 inch (0.25 mm) wide, electro-discharged machined into 
the surface
6 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document

### Page 25

NDIP-1014 REV. B Effective 06/07/2010 
 
 
 
 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
7
3. Eddy Current Instrument, Foerster Defectometer® Model H 2.835 or equivalent —    available 
from: 
Foerster Instruments 
Inc. RIDC Park West 
140 Industry Drive 
Pittsburgh, PA 
15275 U.S.A. 
or          Institut Dr. Friedrich Forster 
Prufgeratebau GmbH & Co. KG In 
Laisen 70 
D-7410 Reutlingen 
Germany 
 
NOTE: This inspection uses an eddy current instrument operating at 
a frequency of 2 MHz. 
NOTE: The equipment described in this procedure is consistent with the 
listed requirements but is not intended to prevent the use of alternate 
equivalent eddy current instruments. 
NOTE: The operating manual for the eddy current instrument applied to 
this inspection should be referenced to obtain a complete understanding of 
instrument operating procedure. 
4. Oscillographic Recorder, Yokogawa OR100 or equivalent — available from: 
Yokogawa Electric Corp. or Yokogawa Corp. of America 
2 Dart Road 9-32, Nakacho 2-chome 
Shenandoah Industrial Musashino-shi 
Newman, GA 302650 Tokyo 18 
U.S.A. Japan 
 
NOTE: This inspection uses an oscillographic recorder operating at a chart speed 
of 2 seconds per division with an input amplifier gain set to 0.5 volts per division. 
The equipment described in this procedure is consistent with the listed 
requirements but is not intended to prevent the use of alternate equivalent 
recorders. 
NOTE: The operating manual for the recorder applied to this inspection should 
be referenced to obtain a complete understanding of recorder operating procedure. 
5. Patch Cord, Defectometer® H 2.835 to Yokogawa OR100 or equivalent. Purchase from 
the eddy current instrument manufacturer or fabricate locally. Refer to instrument and 
recorder operating manuals for wiring diagrams and appropriate connectors. 
6. Borescope, Flexible, 0.181 inch (4 mm) maximum diameter by 39 inches (100 cm) 
long, direct view, 50 degree minimum field of view, Machida FBA-4D-100, or equivalent 
— available from: 
Machida, Inc. 
40 Ramland Road 
Orangeburg, NY 10962 
U.S.A. 
www.machidascope.com

### Page 26

NDIP-1014 REV. B Effective 06/07/2010 
 
 
 
 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
8
7. Light Source, Model LB-24, 24 watt xenon or equivalent — available from: 
Machida, Inc. 
40 Ramland Road 
Orangeburg, NY 10962 
U.S.A. 
www.machidascope.com 
NOTE: The operating manual for the Model LB-24 light source applied to this 
inspection  should be read to obtain a familiarization with the light source 
operating procedure. 
8. Magic Arm Assembly, Bogen Model 2930-Art #143A, with two (2) Super Clamps, Bogen 
Model 2900-Art. #035 — available from: 
 
Bogen Photo Corporation 
565 East Crescent Avenue 
P.O. Box 506 
Ramsey, NJ 07446-0506 
U.S.A. 
www.bogenphoto.com 
info@bogenphoto.com 
 
or      Manfrotto & Co. Italy 
 
 
9. Engine Turning Tool — Breaker bar with spline socket. 
NOTE: It is acceptable to use a motorized engine turning tool, SMI Model TT-70 or 
equivalent — available from: 
Machida, Inc. 
40 Ramland Road 
Orangeburg, NY 10962 U.S.A. 
www.machidascope.com 
10. Low Friction Tape, 3M Electrical Tape, Scotch® #60-1/4, 0.003 inch (0.08 mm) thick 
adhesive backed or equivalent — available from: 
3M 
St. Paul, MN 55144 
U.S.A. 
NOTE: Low friction tape is used to cover the probe coil area to minimize probe wear 
and to provide a low friction contact surface between the probe and the 15th 
stage HPC disk front rail surface. 
 
11. Refer to the similar Instructional Videotape, PN 01V039, “PW4090/PW4098 15th 
Stage HPC Disk Borescope and Eddy Current On-Wing Inspections″.

### Page 27

NDIP-1014 REV. B Effective 06/07/2010 
 
 
 
 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
9
B. INSPECTOR QUALIFICATION/TRAINING REQUIREMENT 
CAUTION: INSPECTION PERSONNEL PERFORMING THE EDDY CURRENT 
INSPECTION PER NDIP-1014 MUST MEET THE FOLLOWING 
REQUIREMENTS: 
• MUST HAVE EXPERIENCE IN EDDY CURRENT INSPECTION 
THEORY AND APPLICATION PER THE INTERNAL REQUIREMENTS OF 
THE OPERATOR/OVERHAUL FACILITY, OR EQUIVALENT TO THE 
NAS-410 LEVEL II REQUIREMENTS; AND 
• SHOULD VIEW THE SIMILAR INSTRUCTIONAL VIDEOTAPE, PN 
01V039, “PW4090/PW4098 15TH STAGE HPC DISK BORESCOPE AND 
EDDY CURRENT ON-WING INSPECTIONS ″ TO OBTAIN A 
FAMILIARIZATION WITH THE INSPECTION APPLICATION. 
 
C. AIRFRAME/ENGINE PREPARATION 
 
CAUTION: THIS INSPECTION IS CONDUCTED ON AN ASSEMBLED 
ENGINE AND ON AN AIRCRAFT INSTALLED ENGINE. 
EVERY PRECAUTION MUST BE TAKEN TO INSURE THE 
INSPECTION IS CONDUCTED IN A SAFE MANNER TO 
PREVENT ACCIDENT OR INJURY. 
NOTE: The engine must cool down for a minimum of 4 hours prior to the inspection to 
allow the HPC area to achieve a temperature equal to or less than 150 degrees 
Fahrenheit (65 degrees Celsius). 
 
CAUTION: APPLICATION OF THE INSPECTION TO AN ENGINE WITH AN HPC 
TEMPERATURE OF GREATER THAN 150 DEGREES 
FAHRENHEIT (65 DEGREES CELSIUS) WILL DAMAGE THE PWA 
105249 EDDY CURRENT PROBE ASSEMBLYAND/OR PROVIDE 
ERRONEOUS EDDY CURRENT INSPECTION RESULTS. 
 
   1. Close the thrust reverser and open the cowl panels as required to obtain access to           
the AP-7 borescope access port and gearbox. 
   2. Remove AP-7 borescope access port plug and sleeve. 
3. Remove the gearbox crank pad cover and install engine rotating device. 
4. Position and secure inspection equipm ent in locations convenient to the AP-7 
borescope access port which will allow comfortable viewing during inspection and 
connection of power cords, connecting cables and light guide.

### Page 28

NDIP-1014 REV. B Effective 06/07/2010 
 
 
 
 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
10
5. Attach and secure the magic arm assembly at an appropriate location on the 
engine. 
CAUTION: IT IS IMPORTANT TO ATTACH THE MAGIC ARM ASSEMBLY ON AN 
EXTERNAL COMPONENT THAT WILL NOT BE DAMAGED BY THE 
ATTACHMENT CLAMP. 
6. Set the magic arm assembly in a position that will hold the borescope and allow 
placement of the borescope in the AP-7 borescope access port without 
interference with external engine components and set the locking lever. 
7. Assemble the borescope. 
a. Attach the light guide of the borescope to the light source. 
b. Place the section of the borescope control body away from the focusing and 
articulating controls into the clamp of the magic arm assembly and secure. 
8. Turn on the light source. 
D. CALIBRATION PROCEDURE 
NOTE: The instructions described in these instructions are based on the 
Defectometer® H 2.835 eddy current instrument. 
If an equivalent eddy current instrument is used, the system application and 
control settings should be adjusted to duplicate the Defectometer® H 2.835 
instrument parameters described in this procedure. 
1. Carefully cover the probe coil contact surfaces of the PWA 105249 eddy current probe 
assembly with a smooth and wrinkle-free layer of low friction tape. 
NOTE: Check the low friction tape for damage prior to calibration and inspection and 
replace if damage is noted. It is necessary to conduct the calibration procedure 
after replacement of the teflon tape. 
2. Connect the probe cable to the Defectometer® H 2.835 eddy current instrument. 
3. Connect the eddy current instrument to the oscillographic recorder using the patch 
cord. 
4. Turn on the eddy current instrument.

### Page 29

NDIP-1014 REV. B Effective 06/07/2010 
 
 
 
 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
11
5. Select the Fe mode by depressing and releasing the Material (M) button until Fe appears on 
the LCD panel. 
6.  Turn on the oscillographic recorder. 
7. Set controls of oscillographic recorder as follows: 
Speed — 2 second/division 
Range — 0.5 Volts/division 
8. Perform the lift-off compensation procedure using the PWA 26964 sensitivity setting 
standard, Figure 4. 
 
 
FIGURE 4 
POSITION OF PWA 105249 EDDY CURRENT PROBE ASSEMBLY ON PWA 26964 
SENSITIVITY SETTING STANDARD DURING LIFT-OFF COMPENSATION PROCEDURE

### Page 30

NDIP-1014 REV. B Effective 06/07/2010 
 
a. With the coil end of the probe approximately 2 inches (51 mm) away from the 
sensitivity setting standard and any other electrically conductive or 
magnetically permeable material or magnet ic field, depress the Lift-Off (L) 
button. 
b. After the Z indicator on the LCD panel starts to flash, place the coil end of the 
probe perpendicular to and on the inspection surface of the standard at a 
location midway between the edges and the simulated defect. 
c. Apply a load to the probe to contact the surface of the standard and 
depress the Zero (Z) button. 
 
9. Set the inspection sensitivity, Figure 5. 
 
FIGURE 5 
POSITION OF PWA 105249 EDDY CURRENT PROBE ASSEMBLY ON PWA 26964 
SENSITIVITY SETTING STANDARD DURING SENSITIVITY SETTING 
 
 
 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
12

### Page 31

NDIP-1014 REV. B Effective 06/07/2010 
 
 
 
 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
13
a. Slowly traverse the probe along the standard while monitoring the recorder 
for the eddy current indication (rapid upscale and return pen movement) from 
the simulated defect, Figure 6. 
 
 
FIGURE 6 
TYPICAL RECORDER TRACE OF EDDY CURRENT INDICATION FROM THE SIMULATED 
DEFECT ON THE PWA 26964 SENSITIVITY SETTING STANDARD DURING CALIBRATION 
 
1) Maintain the coil perpendicular to the standard and traverse the probe across 
the simulated defect at a constant speed of approximately 0.5 inch (12.7 mm) 
per second. 
b. The recorder trace will exhibit a rapid upscale and return pen movement as the 
probe traverses over the simulated defect. 
c. Adjust the eddy current instrument and/or recorder gain control to reproduce the 
recorder trace and amplitude provided on the back of the certification card. 
d. Turn off the osc illographic recorder. 
NOTE: The calibration procedure using the PWA 105249 eddy current probe assembly and 
PWA 26964 sensitivity setting standard should be conducted at the beginning and 
end of each inspection sequence and whenever the inspection has been 
interrupted to maintain accurate inspection results.

### Page 32

NDIP-1014 REV. B Effective 6-2-10 
E. INSPECTION PROCEDURE 
 
 
 
 
FIGURE 7 
BLADE LOADING SLOT and Blade Lock AREAS 
 
 
 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
14

### Page 33

NDIP-1014 REV. B Effective 6-2-10 
 
1. Carefully insert and manipulate the articulating end of the borescope into the AP-7 
borescope access port. The location distribution of the blade loading slot or locking 
areas to be inspected is referred to Figure 7. 
 
a. Manipulate the borescope to obtain the view  required for inspection, Figure 8a and 8b. 
 
 
FIGURE 8a 
A TYPICAL INSPECTION VIEW SHOWING BLADE LOADING SLOT AREA 
 
 
 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
15

### Page 34

NDIP-1014 REV. B Effective 06/07/2010 
 
 
 
 
 16 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
 
 
 
FIGURE 8b 
A TYPICAL INSPECTION VIEW SHOWING BLADE LOOKING AREA 
 
 
2. Rotate the HPC through the gearbox to locate the blade loading slot or locking area to 
be inspected within the inspection view, refer to Figure 8a and 8b. 
3. Rotate the HPC counterclockwise through the gearbox to locate a position on the front 
rail of the 15th stage HPC disk approximately three (3) blades away from the blade 
loading slot or blade locking area to be inspected. 
4. Carefully insert the coil end of the PWA 105249 eddy current probe assembly into the AP-
7 borescope port alongside the borescope. 
5. Continue to insert the probe into the engine cavity until the coil tip contacts the front rail 
of the 15th stage HPC disk, refer to Figure 9. Verify the position of the coil tip against 
the front rail of the disk using the view provided by the borescope. 
 
`

### Page 35

NDIP-1014 REV. B Effective 06/07/2010 
 
17 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
 
EDDY CURRENT PROBE  
      FRONT RAIL 
 
FWD 
POSITION EDDY CURRENT 
PROBE FOR  INSPECTION 
IN THIS AREA 
Figure 9 Eddy Current Inspection on the Front Rail of the HPC 15th Stage Disk 
 
6. Inspect the blade loading slot or blade locking area on the front rail of the 15th stage 
HPC disk. 
a. Turn on the oscillographic recorder. 
b. Apply a slight radial inward pressure to the probe handle to maintain contact of the 
coil tip on the front rail. 
c. Starting at the area three (3) blades away from the blade loading slot or blade 
locking area, rotate the HPC clockwise through the gearbox towards the blade 
loading slot area to be inspected while monitoring the eddy current response. 
d. Continue the HPC rotation until the probe has inspected an area of the front rail that 
encompasses eight (8) blades. 
e. Rotate the HPC counterclockwise through the gearbox back towards the blade 
loading slot area until the area encompassing a total of eight (8) blades has been 
re-inspected to verify the eddy current response. 
e. Turn off the oscillographic recorder. 
7. The recorder trace will exhibit a baseline eddy current response with an amplitude of less 
than 0.5 inch (12.7 mm) as the probe traverses along the inspection area, Figure 10.

### Page 36

NDIP-1014 REV. B Effective 06/07/2010 
18 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
 
FIGURE 10 
A TYPICAL BASELINE RESPONSE 
 
 
a. The recorder trace should be approximately 2 inches (50 mm) long for each 
traverse, refer to Figure 10. 
b. The baseline response should have a wavy appearance with an amplitude 
less than 0.5 inch (12.7 mm) due to a minimal response from the blade 
platforms. 
 
8. An eddy current indication is a rapid upscale and return pen movement, A 
typical eddy current inspection is shown in Figure 11.

### Page 37

NDIP-1014 REV. B Effective 06/07/2010 
 
19 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
 
 
FIGURE 11 
A TYPICAL EDDY CURRENT INDICATION 
 
a. If an indication is observed, evaluate the eddy current response from the two scans. 
b. If necessary, re-traverse the area to repeat and verify the amplitude of the eddy 
current indication. 
9. Remove the eddy current probe from the AP-7 borescope access port.

### Page 38

NDIP-1014 REV. B Effective 06/07/2010 
20 
Pratt & Whitney Proprietary Information – ECCN 9E991 
Use or disclosure of the data contained in this sheet is subject to the restriction on the title page of this document 
 
F. ENGINE RE-ASSEMBLY 
1. Carefully remove the borescope from the AP-7 borescope access port. 
2. Carefully disconnect and remove all test equipment and fixturing from the engine and 
store in the container provided to prevent damage. 
3. Remove the engine rotating device and replace the gearbox crank pad cover. 
4. Replace the AP-7 borescope access port sleeve and plug. 
5. Close the cowl panels and open the thrust reverser.  
 
 
G. REPORTING CRITERIA 
1. Any 15th stage HPC disk front rail which exhibits an eddy current indication with an 
amplitude equal to or greater than 1.0 inch (25.4 mm) must be removed from service. 
 
H. REPORTING 
1. Report inspection results to local Pratt & Whitney Field Representative detailing the 
following information. 
a. Aircraft serial number and engine position. 
b. Engine model, engine serial number, and engine total time and total cycles. 
c. 15th stage HPC disk part number, total part time and total part cycles since new 
and last inspection, if available. 
d. Inspection method and results.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.