# Precision Conversions Service Bulletin PC-757-53A0005: Revision 2

- Rights: © Precision Conversions. Filed by the FAA in regulations.gov docket FAA-2024-1687; AD 2024-12-07 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
- Document: [Precision Conversions Service Bulletin PC-757-53A0005](https://openairdocs.org/service-documents/precision-conversions/pc757-53a0005.md)
- Title as filed: Precision Conversions SB PC-757-53A0005 Rev2
- Pages: 40
- PDF: https://openairdocs.org/files/sha256/67/55/6755bd3aa58cc4bdfeb3cb5bf57f71abd13b17ce79d676d7dfc5966e5afff5e7
- Page: https://openairdocs.org/service-documents/precision-conversions/pc757-53a0005/file/6755bd3aa58c

## Text

Some pages are OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Summary 
Page 1 of 1 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
Number: PC-757-53A0005 SUMMARY 
Date: Ma y 7, 2024  
Revision: 2  
ATA System: 53-00  
  
SUBJECT:  FUSELAGE - STA 333 - STRUCTURAL INSPECTION/REINFORCEMENT OF THE 
LAVATORY SERVICE PANEL 
 
 
BACKGROUND 
 
Precision Conversions has received reports of 
cracking in the structure in and around the lavatory 
service panel. These were found during normal 
maintenance checks. The cracks occur in the 
lavatory service panel access pan, the stringer 
common to the lavatory service panel, and can 
extend into the fuselage skin. 
 
An undetected crack in the skin, stringer, or 
access pan could result in depressurization of the 
airplane and/or loss of the ability to carry aircraft 
loads. 
 
Revision 2 of this Service Bulletin aligns 
instructions with FAA requirements. 
 
 
ACTION 
 
- Complete internal and external 
inspections of the lavatory service panel. 
- Reinforce the surround structure. 
- Replace access pan if necessary. 
Contact Precision Customer Support if 
cracks/damage beyond the limits specified in this 
SB are discovered. 
 
 
COMPLIANCE 
 
Precision considers compliance with this Service 
Bulletin to be mandatory.  Refer to Paragraph I.A 
for compliance requirements. 
 
 
 
 EFFECTIVITY 
 
The following 757-200 airplanes converted to 
Freighter by STC ST01529SE or Combi by 
STC ST02278SE: 
 
Precision Line Numbers: 
 
001-006, 007, 009-015, 017-020, 022-039, 
041-077, 079-081, 083-086, 089, 092, 098, 
101, 103, 106, 107, 111, 112, 114, 118, 120, 
122, 124, 126, 128, 130, 131, 134-136, 139, 
141, 142, 144, 145, 147, 150, 151, 153, 154, 
156, 158, 159, P161, P164, P169, P170. 
 
 
MANPOWER 
 
Total labor hours – 56. See Section I.F for 
detailed estimate breakdown. 
 
 
MATERIAL INFORMATION 
 
Refer to Paragraph II.A., Parts Necessary for 
Each Aircraft.

### Page 2

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 1 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
Number: PC-757-53A0005  
Date: Ma y 7, 2024  
Revision: 2  
ATA System: 53-00  
  
SUBJECT:  FUSELAGE - STA 333 - STRUCTURAL INSPECTION/REINFORCEMENT OF THE 
LAVATORY SERVICE PANEL 
 
THIS SERVICE BULLETIN IS SENT TO THE OPERATORS OF RECORD OF THE AIRPLANES 
SHOWN IN PARAGRAPH I.A., EFFECTIVITY.  IF AN AIRPLANE HAS BEEN LEASED OR SOLD, SEND 
THIS SERVICE BULLETIN TO THE NEW OPERATOR. 
 
I. PLANNING INFORMATION 
 
A. Effectivity 
 
Model 757-200 series airplanes converted to freighter by STC ST01529SE or combi by STC 
ST02278SE. The list below shows airplanes that have been converted via one of the STCs. 
Registration numbers are for reference only: 
 
Precision 
Line No. Model No. Line No. Variable No. Manufacturing Serial No. Registration No. 
001 757-204 440 NB421 26962 VT-BDO 
002 757-23A 257 NB139 24567 C-FLAJ 
003 757-23A 255 NB138 24566 C-FKAJ 
004 757-26DER 231 NE001 24471 HP-2110DAE 
005 757-26DER 235 NE002 24472 N312AL 
006 757-208ER 273 ND201 24739 TF-FIH 
007 757-260ER 348 NE201 25014 N755CS 
008 757-256R 553 ND241 26239 EC-FTR 
009 757-28A 127 NA441 23767 C-GIAJ 
010 757-225 74 NA022 22211 N314ST 
011 757-225 75 NA023 22611 N511KW 
012 757-225 42 NA021 22210 N241AL 
013 757-225 117 NA026 22689 N689GX 
014 757-225 115 NA025 22688 N688GX 
015 757-23N 692 NC059 27598 VT-BDM 
017 757-236 183 NA395 24121 EC-KLD 
018 757-28A 130 NA442 23822 N822PB 
019 757-236 279 NA343 24792 C-FKCJ 
020 757-25CER 475 ND221 25898 VT-BDN 
022 757-236 441 NA348 25597 VQ-BPY 
023 757-21B 232 NB066 24401 B-2899 
024 757-27AER 910 NT885 29611 HP-1810DAE 
025 757-27AER 832 NT881 29607 HP-1910DAE 
026 757-27AER 904 NT884 29610 HP-2010DAE 
027 757-2Z0 554 NB293 25887 B-2832 
028 757-2Z0 615 NB297 27269 B-2839 
029 757-236 449 NA350 25620 OE-LNB 
030 757-25CER 565 ND222 25899 B-2828 
031 757-21B 389 NB262 25258 B-2817 
032 757-222ER 361 NE041 25042 N531UA 
033 757-25CER 574 ND223 25900 B-2829 
034 757-2B6 106 NC042 23687 N557CM 
035 757-2Q8 597 NC071 26273 N751CX 
036 757-2Z0 674 NB302 27512 B-2845 
037 757-2Z0 622 NB298 27270 B-2840 
038 757-28A 704 NB224 26276 VT-BDQ 
039 757-2Z0 833 NT202 29793 B-2856

### Page 3

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 2 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
Precision 
Line No. Model No. Line No. Variable No. Manufacturing Serial No. Registration No. 
041 757-2Z0 624 NB299 27367 B-2841 
042 757-2Z0 595 NB294 27258 B-2836 
043 757-2Z0 822 NT201 29792 B-2855 
044 757-25F 752 NB230 28718 VT-BDA 
045 757-2Z0 669 NB301 27511 B-2844 
046 757-29JER 588 NE301 27203 N757QM 
047 757-2Z0 480 NB292 25886 B-2821 
048 757-2Q8 836 NT378 29380 D-ALEN 
049 757-230ER 446 NE172 25441 N888LT 
050 757-2Q8 821 NT377 29443 D-ALEO 
051 757-2Q8 1006 NT346 30046 D-ALEP 
052 757-25F 928 NT237 30757 B-6150 
053 757-222ER 421 NE147 25397  OO-TFC 
054 757-2G5 671 NB446 26278  B-7342 
055 757-25F 932 NT238 30758 B-7082 
056 757-23N 737 NC062 27974 VT-BDB 
057 757-2Q8 688 NC073 26332 D-ALEQ 
058 757-23N 843 NT283 29330 D-ALEU 
059 757-28A 738 NB226 27621 B-7689 
060 757-2Q8 819 NT376 29442 D-ALES 
061 757-2Q8 639 NC072 27351 D-ALER 
062 757-23N 814 NT282 27976 OE-LNE 
063 757-256ER 943 NT915 29312 OE-LNJ 
064 757-236 873 NT408 29945 OE-LNF 
065 757-23N 779 NT281 27975 OE-LND 
066 757-25CER 685 ND224 27513 B-2848 
067 757-222ER 414 NE145 25368 VP-BHM 
068 757-256ER 948 NT916 30052 OE-LNU 
069 757-236 445 NA349 25598 B-2835 
070 757-236 877 NT409 29946 OE-LNH 
071 757-2Y0 503 NB328 26156 B-2827 
072 757-28A 672 NB222 26275 OE-LNC 
073 757-25CER 698 ND225 27517 B-2849 
074 757-21B 583 NB266 25889 B-2824 
075 757-21K 746 NB571 28674 B-1432 
076 757-21B 575 NB265 25888 B-2823 
077 757-28A 974 NT248 32449 OE-LNI 
079 757-2Y0 482 NB325 26153 B-2831 
080 757-28A 865 NT239 28174 D-ALET 
081 757-28A 723 NB225 28161 D-ALEV 
083 757-204 528 NB428 25623 B-1578 
084 757-21B 585 NB267 25890 B-2825 
085 757-2Z0 613 NB296 27260 B-1463 
086 757-28S 966 NT385 32342 B-2813 
089 757-28S 868 NT383 29217 B-2859 
092 757-28S 961 NT384 32341 B-2812 
098 757-28S 1015 NT386 32343 B-2830 
101 757-2B7 655 NB517 27805 B-1145 
103 757-28S 811 NT382 29216 B-2853 
106 757-2B7 605 NB512 27201 B-1173  
107 757-28S 797 NT381 29215 B-2851  
111 757-2B7 607 NB513 27244 B-208Q 
112 757-230ER 382 NE166 25140 N688SL 
114 757-236 864 NT404 29941 B-20AW 
118 757-236 872 NT407 29944 B-20CX 
120 757-236 867 NT405 29942 B-20E9 
122 757-236 871 NT406 29943 B-20EF 
124 757-28A 1041 NJ004 33101 B-220A 
126 757-28A 1029 NJ003 33100 B-220C 
128 757-28A 1026 NJ001 33098 B-220J

### Page 4

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 3 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
Precision 
Line No. Model No. Line No. Variable No. Manufacturing Serial No. Registration No. 
130 757-256ER 940 NT914 29311 N818NH 
131 757-25C 1048 NJ032 34009 B-2866 
132 757-25C 1047 NJ031 34008 B-2862 
134 757-256ER 616 ND246 26244 N1902S 
135 757-28A 1028 NJ002 33099 B-220Z 
136 757-256ER 617 ND247 26245 N286GB 
139 757-25CER 1009 NN052 32942 B-2869 
141 757-204 861 NT432 28836 C-GAJU 
142 757-25CER 993 NN051 32941 B-2868 
144 757-23N 930 NT286 30548 B-221U 
145 757-256ER 897 NT905 26251 N260AS 
147 757-28A 950 NT245 32446 B-222E 
150 757-2G5 919 NT426 29379 C-GCJS 
151 757-23N 945 NT288 30886 N204UW 
153 757-2G5 922 NT427 30394 N394BR 
154 757-28A 951 NT246 32447 N228DP 
156 757-223ER 852 NT739 29591 N181AN 
158 757-28A 967 NT247 32448 B-223M 
159 757-23N 946 NT289 30887 B-223P 
161 757-28A 782 NT231 28833 N28833 
164 757-2G5 834 NT412 29489 N489BR 
169 757-231 896 NT359 30339 UK75704 
170 757-204 850 NT431 28834 VP-BOO 
 
 
 
B. Reason 
Precision Conversions has received reports of cracking in the structure in and around the lavatory 
service panel. These were found during normal maintenance checks. The cracks occur in the 
lavatory service panel access pan (PN 007D4782), the stringer (S-22R) common to the lavatory 
service panel, and can extend into the fuselage skin.  
An undetected crack in the skin, stringer, or access pan could result in depressurization of the 
airplane and/or loss of the ability to carry aircraft loads. 
C. Description  
This Service Bulletin supplies instructions to perform internal and external inspections of the 
lavatory service panel and surround structure. If cracks are found, the service bulletin directs 
replacement of the access pan, if required, and repair of the surrounding structure. 
D. Compliance 
Precision considers compliance with this Service Bulletin to be mandatory.  
For this SB, some locations are marked RC START and RC END to identify instructions that are 
required to comply with the SB. After release of an FAA AD, an Alternative Method of Compliance 
(AMOC) is required for any deviations to steps between RC START and RC END, including sub-
steps and identified figures. 
Accomplish the required actions, based on the applicable conditions in Table 1, in accordance with 
Paragraph III – Accomplishment Instructions. 
When more than one OPTION is given for a CONDITION, do only one OPTION. When more than 
one ACTION is given for a CONDITION or an OPTION, do all of the ACTION numbers for that 
CONDITION or OPTION.

### Page 5

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 4 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
Table 1: Compliance Requirements  
Condition Action Compliance Time (Whichever 
Occurs Later) 
Repeat 
Interval 
(Not to 
Exceed) 
ALL 
AIRPLANES 
1. Perform inspection of the 
lavatory service panel, 
access pan fastener holes, S-
22R stringer, and external 
skin per Paragraph III, Part 1, 
Inspection. [2] 
Within 5,500 
flight cycles 
after the STC 
ST01529SE or 
ST02278SE 
installation. 
Within 3 months 
after the original 
issue date of this 
Service Bulletin. 
 
CONDITION 1: 
ANY CRACK 
FOUND 
1. Repair or replace all 
cracked parts per Paragraph 
III, Part 2, Repair. 
Before further flight.  
 2. Install reinforcement per 
Paragraph III, Part 3, 
Reinforcement. [1] 
Before further flight.  
CONDITION 2: 
NO CRACK 
FOUND 
OPTION 1: Perform 
inspections of the lavatory 
service panel, access pan 
fastener holes, S-22R 
stringer, and external skin per 
Paragraph III, Part 1, 
Inspection. 
2,000 flight cycles after initial 
inspection performed 
2,000 flight 
cycles 
 OPTION 2: Install 
reinforcement per Paragraph 
III, Part 3, Reinforcement. [1] 
Before further flight.  
CONDITION 3: 
Reinforcement 
installed per 
Paragraph III, 
Part 3, 
Reinforcement 
1. Perform a Detailed Visual 
Inspection of the access pan 
corners per Paragraph III Part 
1, Inspection. 
Within 8,000 flight cycles after the 
Reinforcement Installation. 
8,000 flight 
cycles 
 2. Perform an internal LFEC 
inspection of the external skin 
around all fastener holes 
common to acess pan per 
Paragraph III Part 1, 
Inspection. 
Within 35,000 flight cycles after the 
Reinforcement is installed 
3,500 flight 
cycles 
 3. Perform an 
inspection of 
the doubler-to-
skin fastener 
holes  and skin 
trim area per 
OPTION 
1: 
Internal 
HFEC 
Within 40,000 flight cycles after the 
Reinforcement is installed 
20,000 flight 
cycles

### Page 6

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 5 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
Condition Action Compliance Time (Whichever 
Occurs Later) 
Repeat 
Interval 
(Not to 
Exceed) 
Paragraph III 
Part 1, 
Inspection. 
OPTION 
2: 
External 
LFEC 
Within 40,000 flight cycles after the 
Reinforcement is installed 
13,000 flight 
cycles 
 4. Perform 
inspection of 
the lavatory 
service panel 
cover plate 
fastener holes 
per Paragraph 
III, Part 1, 
Inspection. 
OPTION 
1: 
Internal 
HFEC 
Within 20,000 flight cycles after the 
reinforcement installation. 
20,000 flight 
cycles 
OPTION 
2: 
External 
LFEC 
Within 18,000 flight cycles after the 
reinforcement installation. 
18,000 flight 
cycles 
CONDITION 4: 
Any crack is 
found during any 
post-
reinforcement 
installation 
inspections 
Contact Precision 
Engineering for a repair. 
Before further flight.  
 
[1] The following Engineering Authorizations issued by Precision Conversions provide repairs that 
constitute compliance as Condition 3 and Paragraph III, Part 3. Inspections are required after Part 3, 
Reinforcement as specified in Table 1. 
a. Precision Conversion Number 008, MSN 26239, Precision EA 23-1051 Rev IR 
b. Precision Conversion Number 056, MSN 27974, Precision EA 23-1102 Rev IR 
c. Precision Conversion Number 017, MSN 24121, Precision EA 23-1153 Rev IR 
d. Precision Conversion Number 161, MSN 28833, Precision EA 24-1015 Rev IR 
 
[2] The following Engineering Authorization issued by Precision Conversions provides a repair that 
constitutes compliance with Part 1, Inspections. Inspections per Part 1, Existing Configuration are no 
longer possible. Within 2,000 flight cycles of EA incorporation, perform alternative inspections or 
Reinforcement Installation per Part 3. Contact Precision Conversions for alternative inspection 
instructions. 
a. Precision Conversion Number 001, MSN 26962, Precision EA 22-1147 Rev IR 
 
E. Approval  
This Service Bulletin is FAA approved.

### Page 7

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 6 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
F. Manpower 
The data below shows an estimate of the labor hours necessary to inspect and, if necessary, repair 
and/or rework the lavatory service panel installation. Adjust the estimate with operator labor hour 
data if necessary. The estimate does not include lost time. These are some examples of lost time: 
— Time to schedule the work 
— Time to examine the work 
— Time to find the tools 
Task Number of Persons Labor Hours Elapsed Time (Hours) 
Gain Access 1 2 2 
Perform Inspection 2 4 2 
Reinforcement Installation 2 38 21 
Close-up 1 2 23 
TOTAL FOR EACH AIRPLANE (Inspection & Reinforcement) 46 23 
Replace Service Pan (if necessary) 2 10 28 
TOTAL FOR EACH AIRPLANE (If Service Pan Needs 
Replacement) 56 28 
 
 
G. Material – Price and Availability 
See Paragraph II.A., Parts Necessary for Each Airplane 
H. Weight and Balance 
No effect 
I. Electrical Load Data 
No effect 
J. References 
1. Data supplied with this Service Bulletin: 
Document Revision Title 
007D4780 F Panel Installation – Lavatory Service 
 
NOTE:  Drawing 007D4780 is for reference only. In case of contradictory information, this 
SB prevails. 
 
2. Data not supplied with this Service Bulletin: 
N/A 
3. Drawings used to prepare this Service Bulletin: 
Document Revision Title 
007D4796 T Lavatory Systems Installation

### Page 8

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 7 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
a) Other Documents: 
Boeing 757 SRM. 
Boeing 757 AMM. 
PC-0118-06 Supplemental Maintenance Manual for B757-200PCF Cargo Conversion. 
PC-0118-206 Supplemental Maintenance Manual for B757-200PCC Combi Conversion. 
 
K. Publications Affected 
None 
L. Special Tooling Necessary to Complete This Service Bulletin 
None. Standard maintenance shop tools can be used to implement this modification. 
M. Interchangeability and Intermixability of Parts 
Not applicable

### Page 9

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 8 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
II. MATERIAL INFORMATION 
A. Material - Price and Availability 
 Parts/Materials: 
 
Part Number Name Quantity Notes 
007D4782-3 Pan, Access 1 (b) 
007D4783-11 Doubler, Access 1 (b) 
007D4783-15 Plate, Access Fitting Attach 1 (b) 
007F3615-1 Stringer, Lav 1 (b) 
HL19PB6  Hi-Lok A/R (a)(b) 
HL63PB6 Hi-Lok A/R (a)(b) 
HL19PB5 Hi-Lok A/R (a)(b)  
HL18PB5 Hi-Lok A/R (a)(b)  
HL18PB6 Hi-Lok A/R (a)(b)  
NAS1097KE5 Rivet A/R (a)(b)  
NAS1097KE5 Rivet A/R (a)(b)  
MS20470AD5 Rivet A/R (a)(b)  
Ref. SRM 51-40-08 Repair washers  A/R (a)(b)  
0.063” 2024-T3  
AMS-QQ-A-250/5 Aluminum Clad sheet A/R (a)(c)(d) 
0.080” 7075-T6 
AMS-QQ-A-250/13 Aluminum Clad sheet A/R (a)(c) 
 
(a) Parts supplied by the operator. 
 
(b) Only if cracks are found. 
 
(c) Stock required for local fabrication of parts 
 
(d) Size as shown in figure 8A or 9A 
 
 
B. Special Tools and Equipment 
1. No special tools or equipment are necessary  to do the change in this service bulletin.

### Page 10

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 9 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
III. ACCOMPLISHMENT INSTRUCTIONS 
Part 1 – INSPECTION 
A. General Information 
1. If compliance with this SB is mandated by an Airworthiness Directive (AD), all applicable 
required actions specified must be done. For this SB, some locations are marked RC START 
and RC END to identify instructions that are required to comply with the AD.  An Alternative 
Method of Compliance (AMOC) is required for any deviations to steps between RC START 
and RC End, including sub-steps and identified figures. 
2. The compliance times for the actions in Work Instructions are in I – Planning Information, D - 
Compliance. 
3. A Detailed Visual Inspection is defined in 757 MPD, Chapter 2 (DET). 
4. If it is necessary to remove more parts for ac cess, it is permissible to remove those parts. 
Follow applicable SRM, AMM, and MPD requirements. 
5. If existing skin repairs are present in the area from STA  310.5 - 365.25, Stringer 20R – 24R, 
contact Precision Customer Support with details before beginning work. 
6. Unless otherwise specified, perform inspections for any cracks, flaws, or defects per 
applicable MPD requirements. 
CAUTION: KEEP THE WORK AREA, WIRES AND ELECTRICAL BUNDLES CLEAN OF METAL 
PARTICLES OR CONTAMINATION WHEN YOU USE TOOLS. UNWANTED 
MATERIAL, METAL PARTICLES OR CONTAMINATION CAUGHT IN WIRE 
BUNDLES CAN CAUSE SPARKES OR OTHER ELECTRICAL DAMAGE. 
 
B. Work Instructions 
1. Gain Access per III. Part 4 – ACCESS. 
RC START 
2. Inspection, Existing Configuration 
ALL AIRPLANES – ACTION 1 or CONDITION 2, OPTION 1 
a. Perform an inspection of the la vatory service panel as follows:  
i. Perform an external High-Frequency  Eddy Current (HFEC) at the fastener 
holes common to the external skin as shown in FIGURE 11A and 11B, circle 
note 1. 
ii. Perform the HFEC inspection per B757 NDT manual part 6, 51-00-01. 
b. Perform an inspection of the access pan as follows: 
i. Perform an external High-Frequency Eddy Current (HFEC) at the access pan 
corners as shown in FIGURE 10, circle note 1. 
ii. Perform the HFEC inspection per B757 NDT manual part 6, 51-00-01.

### Page 11

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 10 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
c. Perform an inspection of the lavatory se rvice panel at fastener holes common to the 
cover plate as follows: 
i. Perform an Internal HFEC installation  of the lavatory service panel fastener 
holes common to the cover plate as shown in FIGURE 12, circle note 1. 
ii. Perform HFEC inspection per B757 NDT manual part 6, 51-00-01. 
d. Perform an inspection of the S-22R Stringer between STA 324 and 345: 
i. Perform a Detailed Visual Inspection of  stringer S-22R within 10 inches from 
the access pan direction as shown in Figure 11A, circle note 2.  Refer to 
FIGURE 6A for typical cracking. 
e. Perform a General Visual Inspection of the Lavatory Service Panel Installation and 
attaching structure between STA 324 to 345 and S-21R to S-23R. 
3. Inspection, Reinforced Configuration 
CONDITION 3 — ACTION 1 
a. Perform an internal and external Detaile d Visual Inspection of the access pan corners 
as shown in FIGURE 10, circle note 1. 
CONDITION 3 — ACTION 2 
b. Perform an internal low-frequency eddy curr ent (LFEC) inspection of the external skin 
at all fastener holes common to the access pan as shown in FIGURE 15, circle note 1. 
CONDITION 3 — ACTION 3, OPTION 1 
c. Perform an internal HFEC inspection of t he external skin at the outer row of fasteners 
common to the repair doubler as shown in FIGURE 13, circle note 1. 
d. If skin trim was performed per Part 2 FIGU RE 7, perform internal HFEC inspection of 
the external skin around cutout at all fasteners not covered by access pan common to 
the repair doubler as shown in FIGURE 14, circle note 1. 
CONDITION 3 — ACTION 3, OPTION 2 
e. Perform an external LFEC inspection of the external skin at the outer row of the 
fasteners common to the repair doubler as shown in FIGURE 13, circle note 1. 
f. If skin trim was performed per Part 2 FIGU RE 7, perform an external LFEC inspection 
of the external skin around cutout at all fasteners not covered by access pan common 
to the repair doubler as shown in FIGURE 14, circle note 1. 
CONDITION 3 — ACTION 4, OPTION 1 
g. Perform an internal HFEC inspection of t he lavatory service panel at all fastener holes 
common to the cover plate as shown in FIGURE 12, circle note 1. 
CONDITION 3 — ACTION 4, OPTION 2 
h. Perform an external LFEC inspection of t he lavatory service panel at all fastener holes 
common to the cover plate as shown in FIGURE 12, circle note 1. 
RC END

### Page 12

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 11 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
PART 2 – REPAIR 
A. General Information 
 
Note: 
1. Final shape and size of rework to be determ ined on the aircraft based on fastener pattern. 
2. Unless otherwise specified, apply chemical conversion coating to all repair parts and bare 
surfaces per SRM Chapter 51-20-01. 
3. Ensure no preload on any structure due to repair installation. Maximum pull-up gap to be 
0.010 inch before fastener installation. Fabricate shim if/as required per Document 010-0001. 
4. Install fasteners per SRM Chapter 51-40 requi rements. Unless otherwise specified, maintain 
minimum 2D edge margin and 4D-6D spacing. 
5. If the length of any fastener specified in this service bulletin does not meet installation 
standards given in 757 SRM Chapter 51, then a fastener of the same specification, or an 
approved substitute, with a length which meets the installation standards given in SRM 
Chapter 51 may be used.  
6. Fay surface seal all repair parts with BMS 5-95 sealant per SRM 51-20-05. 
7. Maintain min .030” clearance between edges of parts when applicable. 
8. Plug any remaining fastener holes with sa me diameter type and fastener as OEM detail. 
9. Use care to prevent dam age to adjacent structure. 
10. All rework is to be performed IAW the appropriate AMM or SRM. 
11. Wet install Hi-Loks with sealant using MIL-PRF-81733, Type IV, Class 1, Grade A. 
12. Maintain 2D edge margins and 4D-6D spacing on new/existing fasteners unless specified 
differently. 
13. Where the work instructions include installation of a kept part, a new or serviceable part with 
the same part number can be installed as an alternative to the kept part. 
CAUTION: KEEP THE WORK AREA, WIRES AND ELECTRICAL BUNDLES CLEAN OF METAL 
PARTICLES OR CONTAMINATION WHEN YOU USE TOOLS. UNWANTED 
MATERIAL, METAL PARTICLES OR CONTAMINATION CAUGHT IN WIRE 
BUNDLES CAN CAUSE SPARKES OR OTHER ELECTRICAL DAMAGE.

### Page 13

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 12 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
B. Work Instructions 
 
1. Access 
a. Gain access per III. Part 4 – ACCESS. 
RC START 
CONDITION 1 — ACTION 1 
2. Repair of Cracked Skin: 
a. If external skin cracks equal to or less than 4 inches are found at the upper aft and/or 
lower forward corner of the skin cutout, trim skin as follows:  
NOTE: If length of any skin crack found exceeds 4 inches or location of crack is 
different than shown in Figure 7, contact Precision Engineering. 
 
i. Trim skin shown in Figure 7. 
ii. Perform HFEC inspection of the trim per B757 NDT manual part 6, 51-00-01 to 
ensure complete crack removal. 
iii. Perform an insurance cut of  min 0.040” beyond crack tip. 
iv. Ensure to maintain minimum 1.0R in side trim radius, 0.5R outside radius, and 
minimum 0.32” edge margin from existing fastener locations. 
v. Break sharp edges and maintain minimum 125RA surface finish on trimmed 
edges. 
vi. Finish trim edges per MIL-C-5541, Class 1A and MIL-PRF-23377, Type 1, Class 
C2, then apply paint per MIL-PRF-85285, Type 1, Class H, color white (No. 
17925 per FED-STD-595) or equivalent. 
NOTE:  Acceptable to finish with BMS 10-79, Type III primer and BMS 10-11, Type II, 
BAC 702. Ref. SOPM 20-41-02. 
 
3. Replacement of Cracked Access Pan 
a. If the access pan (P/N 007D4782-1/3) is found to be cracked, it must be replaced as 
follows: 
i. Remove and replace existing Access Pan Precision P/N 007D4782-3 per 
Precision Drawing 007D4780.  
ii. If required, install shim if gap exce eds 0.005 inches before installation of 
fasteners. Shim thickness must not exceed 20% of fastener diameter maximum. 
Reference SRM 51-40-02. 
iii. Permissible to oversize fasteners up  to 1/32. Do not countersink deeper than 
70% of skin thickness. Contact Precision if greater than 1/32 OS is required 
unless otherwise specified.

### Page 14

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 13 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
4. Repair of Cracked Stringers 
a. If the S-22R stringer FWD or AFT of the access pan is cracked, repair as follows: 
i. If crack does not enter the stringer surface common to the outer skin and does 
not span beyond 3 fastener holes from stringer edge per FIGURE 6A, remove 
damage by trimming the stringer as shown in FIGURE 6B. 
ii. If crack enters the stringe r surface common to the outer skin, spans beyond 3 
fastener holes from the edge, or otherwise exceeds the limits specified in 
FIGURE 6A, remove and replace the damaged stringer per FIGURE 6C.  Install 
new stringer P/N 007F3615-1. 
 
5. Replacement of Cracked Doubler 
a. If the Access Pan Doubler (P/N 007D4783- 1/11) is found to be cracked, it must be 
replaced as follows: 
i. Remove and replace existing Access Pan Doubler with P/N 007D4783-11 per 
Precision Drawing 007D4780. 
ii. Permissible to oversize fasteners up to 1/32. Contact Precision if greater than 
1/32 OS is required unless otherwise specified. 
 
6. Replacement of Cracked Fitting Attach Plate 
a. If the Fitting Attach Plate (P/N 007D4783-3/- 15/-19) is found to be cracked, it must be 
replaced as follows: 
i. If Fitting Attach Plate P/N 007D4783-3/ 15 is installed, replace with P/N 
007D4783-15. 
ii. If Fitting Attach Plate P/N 007D4783-19 is installed, replace with a new P/N 
007D4783-19. 
iii. Install replacement Fitting Attach Plate per Precision Drawing 007D4780. 
iv. Permissible to oversize fasteners up to 1/32. Do not countersink greater than 
70% of Plate thickness. 
 
 
RC END 
7. Close Access per III. Part 4 – ACCESS.

### Page 15

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 14 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
PART 3 – REINFORCEMENT 
A. General Information 
Notes: 
1. Unless otherwise specified, these dimensions and tolerances are used: 
 Dimensions are in inches 
 Tolerance on dimensions, other than fastener  margins, is +/- 0.030” for dimensions 
specified in 2 decimal places (X.XX) and +/- 0.010” for dimensions specified in 3 
decimal places (X.XXX). 
 Hole dimensions for standard fasteners are given in 757 SRM Chapter 51 
2. Final shape and size of rework to be determ ined on the aircraft based on fastener pattern. 
3. Unless otherwise specified, apply chemical conversion coating to all repair parts and bare 
surfaces per SRM Chapter 51-20-01. 
4. Ensure no preload on any structure due to repair installation. Maximum pull-up gap to be 
0.010 inch before fastener installation. Fabricate shim if/as required per Document 010-0001. 
5. Install fasteners per SRM Chapter 51-40 requi rements. Unless otherwise specified, maintain 
minimum 2D edge margin and 4D-6D spacing. 
6. Fay surface seal all repair parts with BMS 5-95 sealant per SRM 51-20-05. 
7. Maintain min .030” clearance between edges of parts when applicable. 
8. Plug any remaining fastener holes with sa me diameter type and fastener as OEM detail. 
9. If the length of any fastener specified in th is document does not meet installation standards 
given in Boeing 757-200 SRM Chapter 51, then a fastener of the same specification, or an 
approved substitute, with a length which meets the installation standards given in Boeing 757-
200 SRM Chapter 51-40 and 51-40-03 may be used. 
10. Use care to prevent damage to adjacent structure. 
11. All rework is to be performed IAW the appropriate AMM or SRM. 
12. Wet install Hi-Loks with sealant using MIL-PRF-81733, Type IV, Class 1, Grade A. 
13. Maintain 2D edge margins and 4D-6D spacing on new/existing fasteners unless specified 
differently.  
14. Fillet seal repair doubler and tripler with BMS 5-95 sealant per SRM 51-20-05.

### Page 16

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 15 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
RC START 
B. Work Instructions 
1. Parts 
a. Fabricate the following reinforcement parts: 
i. Fabricate Qty. (1) P/N SB PC-757- 53-A0005-2 Repair Doubler from 0.063” 
thick Clad AL 2024-T3 per QQ-A-250/5 to match the layout shown in FIGURE 
8A (cracks up to 1.5 inches long) or 9A (cracks 1.5 up to 4 inches long). Part 
mark repair part with P/N SB PC-757-53A0005-2. 
ii. Fabricate Qty. (1) P/N SB PC-757-53A 0005-3 Repair Tripler from 0.063” thick 
Clad AL 2024-T3 per QQ-A-250/5 to match the layout shown in FIGURE 8A 
(cracks up to 1.5 inches long) or 9A (cracks 1.5 up to 4 inches long). Part 
mark repair part with P/N SB PC-757-53A0005-3. 
iii. Fabricate Qty. (2) P/N SB PC-757- 53A0005-4 Stringer Splice from 0.080” 
thick Clad AL 7075-T6 per QQ-A-250/13 as shown in FIGURE 8A (cracks up 
to 1.5 inches long) or 9A (cracks 1.5 up to 4 inches long). Part mark repair 
part with P/N SB PC-757-53A0005-4. 
iv. Ensure to maintain minimum 125 RA surface finish. 
v. Apply Alodine per MIL- C-5541, Class 1A, and 2 coats of primer MIL-PRF-
85582, Type I, Class C2 or equivalent per B757-200 SRM 51-20-01. 
vi. Maintain minimum 0.50” corner and inside radii where applicable. 
Fabricate the following only if the external skin was cracked and damage removed via 
Paragraph III, Part 2: 
vii. Fabricate Qty. (1) P/N SB PC-757-53A 0005-1 Repair Filler from 0.063” thick 
Clad AL 2024-T3 per QQ-A-250/5 to match the footprint between the P/N 
007D4782-3 Pan and P/N SB PC-757-53A0005-2 Repair Doubler as shown in 
Figure 8A (cracks up to 1.5 inches long) or 9A (cracks 1.5 up to 4 inches 
long), whichever is applicable. Part mark repair part with 
P/N SB PC-757-53A0005-1. 
NOTE:  Size filler to ensure that fasteners maintain minimum 1.5D edge margin. Remove all 
nicks, scratches, gouges, burrs, and sharp edges from repair parts. Maintain minimum 125 
microinches Ra roughness or smoother on reworked part edges.

### Page 17

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 16 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
2. Reinforcement Installation 
 
CONDITION 1 — ACTION 2 or CONDITION 2 — OPTION 2 
a. Stringer Modification 
i. Remove and discard P/N 007D4784-1/ 3 Stringer Splice Qty. (2) and P/N 
007D4783-5 Stringer Splice Clip Qty. (2) (if present) as shown in FIGURE 5A 
and FIGURE 5B. 
ii. If OEM S-22R Stringers have not been trimmed or replaced with P/N 
007F3615-1 Stringers, trim and plug S-22R Stringers as shown in FIGURE 8C 
or 9C as applicable. 
iii. Install Qty. (2) P/N PC -757-53A0005-4 Stringer Splices as shown in FIGURE 
8C or 9C as applicable. 
b. Filler Installation 
i. If external skin was trimmed per Pa ragraph III, Part 2, install SB PC-757-
53A0005-1 filler per FIGURE 8A (cracks up to 1.5 inches long) or 9A (cracks 
1.5 up to 4 inches long). 
c. Doubler/Tripler Installation 
i. Layout repair as shown in FIGURE 8A  (cracks up to 1.5 inches long) or 9A 
(cracks 1.5 up to 4 inches long), whichever applicable. 
ii. Install P/N  PC-757-53A0005-2 Doub ler and P/N  PC-757-53A0005-3 Tripler 
as shown in FIGURE 8A (cracks up to 1.5 inches long) or 9A (cracks 1.5 up to 
4 inches long) as applicable. 
iii. Taper Doubler and Tripler installation  per FIGURE 8B or FIGURE 9B as 
applicable. 
d. Complete installation per all applicable drawing and SRM requirements and comply 
with all notes per Figure 8D or 9D as applicable. 
RC END 
3. Close Access per III. Part 4 – ACCESS.

### Page 18

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 17 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
PART 4 — ACCESS 
1. Gain Access to the Lavatory Serv ice Panel installation as follows: 
a. Gain access (External): 
i. Gain external access to S-22R at t he location of the lavatory service panel 
(STA 324 to 345). Refer to FIGURE 1. 
b. Gain access (Internal): 
i. Gain internal access to the lavato ry service panel through the E/E Bay, 
between STA 345 and STA 297 as required. Refer to FIGURE 2. 
c. Detach Lines: 
i. If performing Paragraph III, Part 2 – Re pair or Part – 3 Reinforcement, detach 
Drain Pull Cable and Handle, Toilet Drain Line, and Lavatory Dump Valve.  
Retain all hardware for reinstallation.  Refer to FIGURE 3. 
2. Close Access as follows: 
a. Reattach Toilet Drain Line, Lavatory Dump Valve, Drain Pull Cable and Handle as 
required.  Refer to FIGURE 3. 
b. Restore the aircraft to operational configuration.

### Page 19 (OCR)

PRECISION  CONVERSIONS LLC  SERVICE BULLETIN  B757-200PCF/PCC
PC-757-53A0005
- ALERT
STA
368.:
STA
321
LAVATORY
S-22R
S-22R
STA
345
(FRAME)
STA
324
(FRAME)
STA 335
SERVICE PANEL,
LAVATORY
LAVATORY SERVICE PANEL/DRAIN INSTL
FIGURE 1: Location Exterior Inspection Lav Service Pan
Revision 2  PC-757-53A0005
May 7/24  Page 18 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 20 (OCR)

PRECISION  CONVERSIONS LLC  SERVICE BULLETIN  B757-200PCF/PCC
PC-757-53A0005
ALERT
RBL
45
FLOOR PANEL
-STA
STA
324
HOSE ASSY - TANK
'FILL LINE
MOS OUTBO
S-22R
DRAIN LINE,
TOILET  • SERVICE PAN
STA
324
STA
STA  CAM PRAIN PULL
345
FIGURE 2: Location Interior Inspection Lavatory Service Panel
Revision 2  PC-757-53A0005
May 7/24  Page 19 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 21

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 20 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
 
 
 
 
 
 
FIGURE 3: Lavatory Service Panel 
(Cover and Dump Valve not shown)

### Page 22 (OCR)

PRECISION  CONVERSIONS LLC  SERVICE BULLETIN  B757-200PCF/PCC
PC-757-53А0005
ALERT
RIVETS  FITTING  LAV FILL  DRAIN FITTING  AND GASKET  ACCESS PAN
S-22R  S- 22R
SPLICE
STRINGER
ACCESS PAN
'DOUBLER
_PLATE
• NUT PLATE
8X  BOLT
RIVET X2
FIGURE 4: Lavatory Service Panel Attachments
Revision 2  PC-757-53A0005
May 7/24  Page 21 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 23 (OCR)

PRECISION  CONVERSIONS LLC  SERVICE BULLETIN  B757-200PCF/PCC
PC-757-53A0005
• ALERT
REMOVE AND DISCARD  REMOVE AND
STRINGER SPLICE AND  DISCARD P/N
STRINGER SPLICE CLIP  007D4782 ONLY IF
FWD AND AFT OF  CRACKS/DAMAGE
LAVATORY SERVICE  FOUND
REMOVE AND DISCARD
P/N 007D4783-3/15 ONLY
REMOVE AND DISCARD  IF DAMAGE FOUND
P/N 007D4783-1/11 ONLY
IF DAMAGE FOUND
FIGURE 5A: Lavatory Service Panel Removable Structure
STA
324.0
REF
(EXISTING FRAME CLIP)
REMOVE
(STRINGER CLIP
P/N 007D4783-5)
REMOVE
(STRINGER SPLICE
(EXISTING STRINGER)  P/N 007D4784-1/3)
FIGURE 5B: Stringer Splice and Clip Removal, STA 324 (Shown)
STA 345 (Similar)
Revision 2  PC-757-53A0005
May 7/24  Page 22 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 24 (OCR)

PRECISION  CONVERSIONS LLC  SERVICE BULLETIN  B757-200PCF/PCC
PC-757-53A0005
ALERT
STA
324.0
REF
CRACK BEYOND
FIRST 3 FASTENERS:
REPLACE STRINGER
CRACK WITHIN FIRST
3 FASTENERS:
TRIM
(EXISTING STRINGER)
CRACK IN SURFACE
COMMON TO OUTER SKIN  OUTBD ,
REPLACE STRINGER
FIGURE 6A: Stringer Crack Identification, STA 324 (Shown)
STA 345 (Similar)
STA
324.0
REF
TRIM LOCATION
(EXISTING STRINGER)  ENSURE NO CRACKS LEFI
R.50 TYP
OUTBD ,
FIGURE 6B: Stringer Crack Removal, STA 3245 (Shown)
STA 345 (Similar)
Revision 2  PC-757-53A0005
May 7/24  Page 23 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 25

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 24 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
FIGURE 6C: Replacement Stringer Installation, STA 324 (Shown) 
STA 345 (Similar)

### Page 26 (OCR)

PRECISION  SERVICE BULLETIN  B757-200PCF/PCC
CONVERSIONS LLC
PC-757-53A0005
ALERT
STA 345  STA 333.45  STA 324
REF  REF  REF
MAINTAIN MIN 1.0R
EXTENDED
INSIDE RADIUS
OEM SKIN TRIM
(TYPICAL)
- S-21R
MAINTAIN MINIMUM
0.032 EDGE MARGIN FROM
EXISTING FASTENER LOCATIONS
AROUND TRIM EXTENSION
(TYPICAL)
MAINTAIN MIN 0.5R
OUTSIDE RADIUS
S-22R
(WITHIN 1.5  (WITHIN 1.5
FROM OEM SKIN LINE)  FROM OEM SKIN LINE)
(WITHIN 4.0  (WITHIN 4.0
FROM OEM SKIN LINE)  FROM OEM SKIN LINE)
S-23R
OEM SKIN TRIM LINE
VIEW LOOKING INBOARD  • FWD
FIGURE 7: External Skin Trim
Revision 2  PC-757-53A0005
May 7/24  Page 25 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 27 (OCR)

PRECISION  SERVICE BULLETIN  B757-200PCF/PCC
CONVERSIONS LLC
PC-757-53A0005
ALERT
- S-21R  SB 53A0005-3  TRIPLER  SB 53A0005-2  DOUBLER  1.00  EDGE OF DOUBLER/TRIPLER  TO MATCH FOOTPRINT  OF ACCESS DOOR  - S-23R  -FWD
EDGE OF OEM  FRAME FLANGE  UP
STA  324
STA  333.45  UPR AFT CRACK  LOCATION (TYP)  HL19PB5 IN NEW  LOCATIONS  LOCATION (TYP)  VIEW LOOKING INBOARD
P/N 007D4782-3  (PAN DOUBLER)
SKIN TRIM LINE AND  FILLER SB 53A0005-1  LOCATION  S-22R
FIGURE 8A: Repair/Reinforcement Installation, Crack up to 1.5 Inch Long
Revision 2  PC-757-53A0005
May 7/24  Page 26 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 28

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 27 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
 
 
 
 
 
 
 
 
 
 
FIGURE 8B: Details

### Page 29 (OCR)

PRECISION  CONVERSIONS LLC  SERVICE BULLETIN  B757-200PCF/PCC
PC-757-53A0005
ALERT
53A0005-4 STRINGER CLIP
S TA
324.0
REF
• FRAME CLIP
REF
TRIM END HOLE
LOCATION
TYP
SECTION C-C
TRIM IF/AS REQD ON INSTL
MAINTAIN 2D EM
PLUG HOLES IN STRINGER S
WITH MS2047 OADS
R. 19 TO NEST IN STG
SECTION B-B  TYP 2 PL
STA 324 SHOWN
STA 345 SIMILAR  3.8  1.0
R.40
2 PL
R.25 TYP
1.7
7.0 REF
(TRIM ON INSTL)
SB 53A0005-4 STRINGER CLIP (QTY 2)
LENGTH TO BE TRIMMED ON INSTL
FIGURE 8C: Details
Revision 2  PC-757-53A0005
May 7/24  Page 28 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 30 (OCR)

PRECISION  CONVERSIONS LLC  SERVICE BULLETIN  B757-200PCF/PCC
PC-757-53A0005
- ALERT -
FASTENER CODES - INSTALL PER SRM 51-40 REQUIREMENTS:
. HL 19PB6 HI-LOK IN EXISTING HOLE LOCATION
USE COUNTERSINK REPAIR WASHERS PER SRM 51-40-08***
• PICKUP HL FASTENER FASTENER PER D4780 REQUIREMENTS  USE COUNTERSINK REPAIR WASHERS PER SRM 51-40-08
* PICKUP EXISTING STRINGER FASTENER INSTALL HL63PB6 PER 007D 4780 REQUIREMENTS  USE COUNTERS INK REPAIR WASHERS PER SRM 51-40-08***
+ NAS1097 KES, NEWHOLE LOCATION
# HL 19PBS HI-LOK, NEW HOLE LOCATION THRU DOUBLER AND TRIPLER
• EXISTING FASTENER LOCATION. INSTALL SAME SIZE AND TYPE AS PRODUCTION  1/32 INCH OVERSIZE IF REQUIRED. USE COUNTERSINK REPAIR WASHERS PER SRM 51-40-08*
*** AT LOCATIONS WHERE BRILES RIVETS ARE INSTALLED, USE REPAIR
WASHERS PER SRM 53-00-01R 1 IN EXISTING COUNTERSINKS
< MAINTAIN MINIMUM 0.030" BETWEEN EDGE OF PARTS.
2 IT IS ACCEPTABLE TO PERFORM THE FOLLOWING AS REQUIRED TO
PROPERLY INSTALL FASTENERS AT MILL POCKET EDGE LOCATIONS:
1. IT IS ACCEPTABLE TO LOCALLY BLEND CHEM-MILL TO AVOID
INTERFERENCE BETWEEN THE FASTENER AND CHEM-MILL RADIUS. BLEND
THE CHEM MILL STEP SMOOTH WITH MINIMUM 10:1 TAPER RATIO. THEN
FINISH PER OEM/STC REQUIREMENTS. ENSURE TO MAINTAIN MINIMUM
0.040" SKIN THICKNESS.
2. IT IS ACCEPTABLE TO TRIM LAV PAN LOCALLY PER SRM PROVIDED THAT
MINIMUM 0.32" EDGE MARGIN IS MAINTAINED FOR EXISTING LAV PAN
FASTENERS. ENSURE TO BREAK SHARP EDGES AND TO MAINTAIN MINIMUM
0.50R TRIM RADIUS AND MINIMUM 63RA SURFACE FINISH ON TRIMMED
EDGE. FINISH EDGES WITH BMS 10-11, TYPE I AND APPLY PAINT PER BMS
10-11 TYPE II, COLOR WHITE (BAC 702), APPROXIMATELY 0.002 THICK.
3. INTER-PITCH FASTENERS TO MAINTAIN MINIMUM 0.600" FASTENER SPACING
FROM EXISTING LAV PAN FASTENERS.
FILLER TO MATCH FOOTPRINT BETWEEN DOUBLER AND
LAVATORY PAN. ENSURE THAT FASTENERS MAINTAIN MIN 1.5D THRU THE FILLER.
_ MAINTAIN MINIMUM 0.35 INCH EDGE MARG IN AT EXISTING FASTENER LOCATIONS
AROUND TRIM EXTENSION (TYPICAL)
HL18PB5 OPTIONAL IF SPACE FOR RIVETING IS LIMITED
FIGURE 8D: Fastener and Flag Note Requirements
Revision 2  PC-757-53A0005
May 7/24  Page 29 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 31 (OCR)

PRECISION  SERVICE BULLETIN  B757-200PCF/PCC
CONVERSIONS LLC
PC-757-53A0005
ALERT
SB 53A 0005-3  TRIPLER  SB 53A 0005-2  DOUBLER  EDGE OF DOUBLER/TRIPLER  TO MATCH FOOTPRINT  OF ACCESS DOOR  S-23R  - FWD
EDGE OF OEM  FRAME FLANGE
STA  324
STA  333.45  CRACK LOCATION  1.5-4 IN (TYPICAL)  HL 19PB5  IN NEW LOCATIONS  VIEW LOOKING INBOARD
P/N 007D4782-3  (PAN DOUBLER)
SKIN TRIM LINE AND  FILLER SB-53A0005-1  LOCATION  S-22R
FIGURE 9A: Repair Installation - Crack 1.5 - 4.0 Inch Long
Revision 2  PC-757-53A0005
May 7/24  Page 30 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 32

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 31 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
 
 
 
 
 
 
 
 
FIGURE 9B: Details

### Page 33 (OCR)

PRECISION  CONVERSIONS LLC  SERVICE BULLETIN  B757-200PCF/PCC
PC-757-53A0005
ALERT
53A0005-4 STRINGER CLIP
S TA
324.0
REF
• FRAME CLIP
REF
TRIM END HOLE
LOCATION
TYP
SECTION C-C
TRIM IF/AS REQD ON INSTL
MAINTAIN 2D EM
PLUG HOLES IN STRINGER S
WITH MS2047 OADS
R. 19 TO NEST IN STG
SECTION B-B  TYP 2 PL
STA 324 SHOWN
STA 345 SIMILAR  3.8  1.0
R.40
2 PL
R.25 TYP
1.7
7.0 REF
(TRIM ON INSTL)
SB 53A0005-4 STRINGER CLIP (QTY 2)
LENGTH TO BE TRIMMED ON INSTL
FIGURE 9C: Details
Revision 2  PC-757-53A0005
May 7/24  Page 32 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 34 (OCR)

PRECISION  CONVERSIONS LLC  SERVICE BULLETIN  B757-200PCF/PCC
PC-757-53A0005
- ALERT -
FASTENER CODES - INSTALL PER SRM 51-40 REQUIREMENTS:
. HL 19PB6 HI-LOK IN EXISTING HOLE LOCATION
USE COUNTERSINK REPAIR WASHERS PER SRM 51-40-08***
• PICKUP HL FASTENER FASTENER PER D4780 REQUIREMENTS  USE COUNTERSINK REPAIR WASHERS PER SRM 51-40-08
* PICKUP EXISTING STRINGER FASTENER INSTALL HL63PB6 PER 007D 4780 REQUIREMENTS  USE COUNTERS INK REPAIR WASHERS PER SRM 51-40-08***
+ NAS1097 KES, NEWHOLE LOCATION
# HL 19PBS HI-LOK, NEW HOLE LOCATION THRU DOUBLER AND TRIPLER
• EXISTING FASTENER LOCATION. INSTALL SAME SIZE AND TYPE AS PRODUCTION  1/32 INCH OVERSIZE IF REQUIRED. USE COUNTERSINK REPAIR WASHERS PER SRM 51-40-08*
*** AT LOCATIONS WHERE BRILES RIVETS ARE INSTALLED, USE REPAIR
WASHERS PER SRM 53-00-01R 1 IN EXISTING COUNTERSINKS
< MAINTAIN MINIMUM 0.030" BETWEEN EDGE OF PARTS.
2 IT IS ACCEPTABLE TO PERFORM THE FOLLOWING AS REQUIRED TO
PROPERLY INSTALL FASTENERS AT MILL POCKET EDGE LOCATIONS:
1. IT IS ACCEPTABLE TO LOCALLY BLEND CHEM-MILL TO AVOID
INTERFERENCE BETWEEN THE FASTENER AND CHEM-MILL RADIUS. BLEND
THE CHEM MILL STEP SMOOTH WITH MINIMUM 10:1 TAPER RATIO. THEN
FINISH PER OEM/STC REQUIREMENTS. ENSURE TO MAINTAIN MINIMUM
0.040" SKIN THICKNESS.
2. IT IS ACCEPTABLE TO TRIM LAV PAN LOCALLY PER SRM PROVIDED THAT
MINIMUM 0.32" EDGE MARGIN IS MAINTAINED FOR EXISTING LAV PAN
FASTENERS. ENSURE TO BREAK SHARP EDGES AND TO MAINTAIN MINIMUM
0.50R TRIM RADIUS AND MINIMUM 63RA SURFACE FINISH ON TRIMMED
EDGE. FINISH EDGES WITH BMS 10-11, TYPE I AND APPLY PAINT PER BMS
10-11 TYPE II, COLOR WHITE (BAC 702), APPROXIMATELY 0.002 THICK.
3. INTER-PITCH FASTENERS TO MAINTAIN MINIMUM 0.600" FASTENER SPACING
FROM EXISTING LAV PAN FASTENERS.
FILLER TO MATCH FOOTPRINT BETWEEN DOUBLER AND
LAVATORY PAN. ENSURE THAT FASTENERS MAINTAIN MIN 1.5D THRU THE FILLER.
_ MAINTAIN MINIMUM 0.35 INCH EDGE MARG IN AT EXISTING FASTENER LOCATIONS
AROUND TRIM EXTENSION (TYPICAL)
HL18PB5 OPTIONAL IF SPACE FOR RIVETING IS LIMITED
FIGURE 9D: Fastener and Flag Note Requirements
Revision 2  PC-757-53A0005
May 7/24  Page 33 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 35

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 34 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
 
 
 
 
 
 
FIGURE 10: Inspection Area, Access Pan Corner 
 
1

### Page 36

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 35 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
 
FIGURE 11A: Inspection Area, External Skin-to-Pan Fasteners, Internal 
 
FIGURE 11B: Inspection Area, External Skin-to-Pan Fasteners, External 
  
1 
2 
10 in 
2
10 in 
1

### Page 37

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
Revision 2  PC-757-53A0005 
May 7/24  Page 36 of 38 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
FIGURE 12: Inspection Area, Lavatory Service Panel Cover 
 
1

### Page 38 (OCR)

PRECISION  I SERVICE BULLETIN  B757-200PCF/PCC
CONVERSIONS LLC
PC-757-53A0005
ALERT
STA  STA  STA
345  333.45  324
- S-21R
SB 53-0005-3
TRIPLER
SB 53-0005-2
DOUBLER
S-22R
- S-23R
• FWD
P/N 007D4782-3
(ACCESS PAN)
FIGURE 13: Inspection Area, Doubler Outer Fastener Rows
STA  STA  STA
345  333.45  324
EDGE OF OEM
FRAME FLANGE
_ S-21R
SB 53-0005-3
TRIPLER
UPR AFT CRACK  SB 53-0005-2
SKIN TRIM LINE AND  LOCATION (TYP)  DOUBLER
FILLER SB 53-0005-4
LOCATION
S-22R
LWR FWD CRACK
LOCATION (TYP)
S-23R
• FWD
P/N 007D4782-3
(PAN DOUBLER)
FIGURE 14: Inspection Area, External Skin Removal
Revision 2  PC-757-53A0005
May 7/24  Page 37 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 39 (OCR)

PRECISION  I SERVICE BULLETIN  B757-200PCF/PCC
CONVERSIONS LLC
PC-757-53А0005
ALERT
STA  STA  STA
345  333.45  324
- S-21R
SB 53-0005-3
TRIPLER
SB 53-0005-2
DOUBLER
S-22R
S-23R
- FWD
P/N 007D4782-3
(ACCESS PAN)
FIGURE 15: Inspection Area, External Skin to Access Pan
Revision 2  PC-757-53A0005
May 7/24  Page 38 of 38
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008

### Page 40

B757-200PCF/PCC 
SERVICE BULLETIN 
PC-757-53A0005 
 
ALERT 
PRECISION CONVERSIONS LLC, 9800 SW NIMBUS AVENUE, BEAVERTON, OREGON, 97008 
 
Number: PC-757-53A0005   Customer Name:       
 
Release Date: May 7, 2024 Aircraft MSN:    
 
Revision: 2     Date of feedback:     
 
 
The purpose of this form is to provide Precision Conversions with notification of incorporation of the 
Service Bulletin.  Additionally, it gives our customers an opportunity to provide feedback concerning 
difficulties with implementation, errors in the bulletin, or suggestions for improvement on this or any future 
bulletins.  Please complete this form and return it to Precision Conversions via mail, fax, or email as 
provided below.  Attach additional sheets as necessary. 
 
 
 All work related to this service bulletin was completed on _________________, 20____.  
 Please list any exceptions:   
 
 
 
 
 The following installation deviations required additional engineering support from Precision 
Conversions: 
  
 
 
 
 
 An error (procedural or typographical) has been noted in paragraph _____ on page _____. 
 Please Explain:  
 
 
 
 
 Recommend paragraph _____ on page _____ be changed as follows: 
  
 
 
 
 
 I would like to discuss the above.  Please contact me. 
  
Submitted by: ________________________________________    Phone: ________________________ 
  
  
 
Please return this form to the attention of Customer Support via email:  
 
Precision Conversions, LLC 
support@precisionaircraft.com

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.