# Messier-Bugatti-Dowty Service Bulletin 32-17M

Copy: No revision named ("U.S. DOT/FAA - Service Bulletin - 32-17M Rev 0 K0654"), 10 pages: PDF https://openairdocs.org/files/sha256/91/92/91925f59d260dd023667770ad53ec06246dd42624e3aa21a84b939c33d136854; text https://openairdocs.org/service-documents/safran-landing-systems/32-17m/file/91925f59d260.md. Rights: © Messier-Dowty. Filed by the FAA in regulations.gov docket FAA-2014-1001; AD 2015-04-01 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Messier-Dowty](https://openairdocs.org/service-documents/safran-landing-systems.md) (issued as Messier-Bugatti-Dowty)
- Type: Service bulletin (Service Bulletin)
- Number: 32-17M
- Page: https://openairdocs.org/service-documents/safran-landing-systems/32-17m

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2015-04-01](https://openairdocs.org/ad/2015-04-01.md), effective Mar 30, 2015: No revision named

Also cited in [1 proposed AD](https://openairdocs.org/service-documents/safran-landing-systems/32-17m/proposed.md).

## Text (10 pages)

Rights: © Messier-Dowty. Filed by the FAA in regulations.gov docket FAA-2014-1001; AD 2015-04-01 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

Service Bulletin No. 32-17M
Page 1 of 6
CAGE: K0654
Cheltenham Road, Gloucester, GL2 9QH, England 
Telephone: +44 (0) 1452 712424 Fax: +44 (0) 1452 713821
SERVICE BULLETIN
Messier-Dowty Ltd
 ©MESSIER-BUGATTI-DOWTY 2014 (AND SUBSEQUENT REVISION PAGE DATES) 
This document and all information contained herein is the sole pr operty of Messier-Bugatti-Dowty. No intellectual property righ ts are 
granted by the delivery of this document or the disclosure of its content. This document shall not be reproduced to a third party without the 
express written consent of Messier-Bugatti-Dowty.
Safran and Messier-Bugatti names are marks owned respectively by  Safran and Messier-Bugatti-Dowty companies. The mark Dowty is 
used under licence.
LANDING GEAR - NOSE LANDING GEAR - INSPECTION OF SLIDING TUBE
1. Planning Information
A. Effectivity
Aircraft affected: Shorts Skyvan - All Marks
Unit Affected: Nose Landing Gear
Part/Type Nos.: EH1833, EH1839 and EH1887 (Nose Landing Gear)  
which includes 
200621619 and EH183345 (Sliding Tube)
NOTE: This Service Bulletin is applicable to NLG Sliding Tubes installed on aircraft 
and held as spares.
B. Concurrent Requirements
(1) None.
C. Reason
(1) A fracture of a Nose Landing Gear Sliding Tube has occurred due to fatigue cracking.
D. Description
(1) Messier-Dowty Limited tells you that this Service Bulletin includes details to do a one 
off visual inspection and a one off fluorescent penetrant inspection (FPI) for cracking of 
the Nose Landing Gear Sliding Tube.
E. Compliance
(1) It is expected that the contents of this Service Bulletin will be made MANDATORY by 
an EASA Airworthiness Directive.
(2) Messier-Dowty Limited recommends that y ou do the detailed visual inspection at or 
before 1 month from the issue date of this Service Bulletin.
(3) Messier-Dowty Limited recommends that you do the fluorescent penetrant inspection 
(FPI) at or before 3 months from the issue date of this Service Bulletin.
F. Approval
(1) The technical content of this Service Bulletin has been approved under the authority of 
the EASA Design Organisation Approval No. EASA.21J.068.
Nov 1/2014

### Page 2

Service Bulletin No. 32-17M 
Page 2
SERVICE BULLETIN
Messier-Dowty Ltd
G. Manpower
(1) Messier-Dowty Limited make an estimate t hat it will take approximately 0.5 man-hours 
to do the detailed visual inspection and 4 man-hours to do the fluorescent penetrant 
inspection of this Service Bulletin. The elap sed time will be 0.5 hours for the detailed 
visual inspection and 4 hours for the fluorescent penetrant inspection. 
NOTE: It is assumed that the equipment has been placed in a maintenance 
state. The man-hour estimates do not include preparation, close out or 
administrative functions.
H. Weight and Balance
(1) None.
I. References
(1) Messier-Dowty Limited Component Maintenance Manual, 32-20-77.
(2) Messier-Dowty Standard Practices Manual, 20-00-10.
(3) Skyvan Maintenance Manual. 
(4) Shorts Service Bulletin 32-74.
J. Other Publications Affected
(1) None.
2. Material Information
A. Material - Price and Availability
(1) None.
B. Material Necessary for Each Unit
(1) Refer to Appendix A.
3. Accomplishment Instructions
A. Procedure for detailed visual inspection of the external diameter of the Sliding Tube:
(1) Make sure the aircraft is in a safe condition: refer to the Skyvan Maintenance Manual.
(2) If necessary to view the area of inspection on the Sliding Tube outside diameter (refer 
to Figure 1) raise the aircraft nose (to extend the Sliding Tube) using a suitable jack: 
refer to the Skyvan Maintenance Manual (Chapter 7, Para 2).
(3) Fully clean the area of inspection on the Sliding Tube outside diameter, remove all 
grease and dirt: refer to CLEANING in CMM 32-20-77.
(4) Perform a detailed visual inspection under 10 x magnification for cracking of the Sliding 
Tube outside diameter in the area of inspection shown in Figure 1.
(5) Report any inspection findings to MBD CSC (e-mail to: pse.glostec@safranmbd.com
and aogcsc@safranmbd.com) and wait to receive instruction before next flight.
(6) If necessary, lower the aircraft and remove the jacks: refer to the Skyvan Maintenance 
Manual.
B. Procedure for fluorescent penetrant inspection of  the external diameter of the Sliding Tube:
(1) Make sure the aircraft is in a safe condition: refer to the Skyvan Maintenance Manual.
Nov 1/2014

### Page 3

Service Bulletin No. 32-17M 
Page 3
SERVICE BULLETIN
Messier-Dowty Ltd
(2) If necessary to view the area of inspecti on on the Sliding Tube outside diameter (refer 
to Figure 1) raise the aircraft nose (to extend the Sliding Tube) using a suitable jack: 
refer to the Skyvan Maintenance Manual (Chapter 7, Para 2).
(3) Fully clean the area of inspection on the Sliding Tube outside diameter, remove all 
grease and dirt: refer to CLEANING in CMM 32-20-77.
(4) Perform the fluorescent penetrant inspec tion procedure in Appendix A for cracking of 
the Sliding Tube outside diameter in the area of inspection shown in Figure 1.
(5) Report any inspection findings to MBD CSC (e-mail to: pse.glostec@safranmbd.com
and aogcsc@safranmbd.com) and wait to receive instruction before next flight.
(6) If necessary, lower the aircraft and remove the jacks: refer to the Skyvan Maintenance 
Manual.
C. Identification
(1) After you have done the detailed visual inspection and the fluorescent penetrant 
inspection of this Service Bulletin:- writ e Service Bulletin number 32-17M in the 
applicable aircraft and nose landing gear records.
(2) After you have done the detailed visual inspection and the fluorescent penetrant 
inspection of this Service Bulletin: complete  the Proforma (Appendix B) and send it to 
pse.glostec@safranmbd.com.
Nov 1/2014

### Page 4

Service Bulletin No. 32-17M 
Page 4
SERVICE BULLETIN
Messier-Dowty Ltd
Area of Inspection
Figure 1
SKYVA7442-1
FORK SUB-ASSEMBLY
(1-140A or 1-145A)
LOCK WASHER (1-125)
WASHER (1-115)
BOLT (1-110)
LOCKING PLATE
(1-120)
BLEEDER
SCREW
STEERING
TUBE
SLIDING TUBE
GREASE
NIPPLE
INFLATION
VALVE
CASTORING
STOP
STEERING
BRACKET
AIRCRAFT
ATTACHMENT
BRACKET
TOGGLE
SUB-ASSEMBLY
INFLATION
VALVE
INSPECTION
AREA
ENLARGED VIEW OF INSPECTION AREA
[APPLICABLE AFTER SB 32-2M (AS SHOWN) AND BEFORE SB 32-2M]
PERFORM THE DETAILED VISUAL
INSPECTION AND FLUORESCENT
PENETRANT INSPECTION
IN THE SHADED AREA ALL
AROUND SLIDING
TUBE CIRCUMFERENCE
25mm (1in)
PAINTED AREA
DO NOT INSPECT
100mm (4in)
Nov 1/2014

### Page 5

Service Bulletin No. 32-17M 
Page 5
SERVICE BULLETIN
Messier-Dowty Ltd
4. Messier-Bugatti-Dowty and Messier Services Contacts
A. Refer to the Messier-Bugatti-Dowty website ( safranmbd.com) for the latest list of contact 
names, addresses and numbers.
Original Equipment Manufacturers
Messier-Dowty Inc.
574 Monarch Avenue
Ajax, Ontario
L1S 2G8 
CANADA
Tel: 905-683-3100
Fax: 905-683-6936
Messier-Dowty Limited
Cheltenham Road
Gloucester
GL2 9QH
ENGLAND
Tel: +44(0)1452 712424
Fax: +44(0)1452 713821
Messier-Bugatti-Dowty
Landing Gear & Systems
Integration Division
Inovel Parc Sud
BP 10
78140 Velizy - Villacoublay
FRANCE
Tel: +33 146 29 18 00
Fax: +33 146 29 87 70
Customer Support Centers (CSC)
For AOG (commercial and technical): aogcsc@safranmbd.com
For Europe - Africa - Middle East customers: eamecsc@safranmbd.com
Tel: +33 1 5521 2590
For Americas customers: americacsc@safranmbd.com
Tel: +1 404 305 2626
For Asia-Pacific customers: asiacsc@safranmbd.com
Tel: +65 6245 5688
Repair and Overhaul Facilities
Messier Services R&O Facility
574 Monarch Avenue
Ajax, Ontario
L1S 2G8
CANADA
Tel: 905-683-3100
Fax: 905-683-0378
Messier Services R&O Facility
Meteor Business Park
Cheltenham Road
Gloucester GL2 9QL
ENGLAND
Tel: +44(0)1452 713111
Fax: +44(0)1452 716500
Messier Services R&O Facility
3, rue Antoine de St Exupery, 
BP110
67124 Molsheim Cedex
France
Tel: (33) 38838 9200
Fax: (33) 38838 9399
Messier Services (Asia) Pte. Ltd. 
R&O Facility
21 Loyang Crescent, 
Loyang Industrial Estate
SINGAPORE 508985
Tel: (65) 6545 9455
Fax: (65) 6542 3936
Messier Services R&O Facility - 
Americas
Av. La Noria
Parque Industrial Querétaro
Carretera QRO-SLP, Km. 28.5
Querétaro, QRO 76220
MEXICO
Tel: +52 (442) 19 25 800
Fax:+52 (442) 19 25 801
HYDREP Aéroport de 
Dinard-Pleurtuit-Saint-Malo
Bâtiment 20
BP90154
35801 DINARD Cedex
FRANCE
Tel: (33) 2 99 82 79 79
Fax: (33) 2 99 82 79 97
Nov 1/2014

### Page 6

INTENTIONALLY BLANK
Service Bulletin No. 32-17M 
Page 6
SERVICE BULLETIN
Messier-Dowty Ltd

### Page 7

Service Bulletin No. 32-17M
Page 1 of 2
CAGE: K0654
Cheltenham Road, Gloucester, GL2 9QH, England 
Telephone: +44 (0) 1452 712424 Fax: +44 (0) 1452 713821
SERVICE BULLETIN
Messier-Dowty Ltd
 ©MESSIER-BUGATTI-DOWTY 2014 (AND SUBSEQUENT REVISION PAGE DATES) 
This document and all information contained herein is the sole pr operty of Messier-Bugatti-Dowty. No intellectual property righ ts are 
granted by the delivery of this document or the disclosure of its content. This document shall not be reproduced to a third party without the 
express written consent of Messier-Bugatti-Dowty.
Safran and Messier-Bugatti names are marks owned respectively by  Safran and Messier-Bugatti-Dowty companies. The mark Dowty is 
used under licence.
APPENDIX - A
ON-WING NDT (FPI) PROCEDURE FOR NOSE LANDING GEAR SLIDING TUBE
1. INTRODUCTION
A. This procedure shall only be carried out by level 2 personnel qualified and certificated in 
accordance with EN 4179/NAS410 (or equivalent) in the Penetrant Testing method.
2. EQUIPMENT
A. A supply of cold degreasing fluid (e.g. Methelated Spirit, Acetone or similar).
B. A supply of lint free cloths and paper towels.
C. All penetrant materials shall be qualified to QPL AMS 2644.
D. Type 1 Fluorescent Penetrant, Level 3 sensitivity (mln), Solvent Removable. [Refer to 
ASTME1417 for classifications]
E. Method C solvent remover -Class 2 (non-halogenated).
F. Developer: form d. (Non aqueous wet).
G. UV-A inspection lamp with a mini mum u/v intensity of 1,000 micro W/cm 2 at the inspection 
surface.
H. A black out cover to aid ultraviolet inspection.
NOTE: The inspection must be carried out in a safe, clean, darkened, well-ventilated 
area suitable for ultraviolet inspection.
3. PROCEDURE
WARNING: THE VAPOURS FROM THE EVAPORATING, VOLATILE SOLVENT 
DEVELOPER CARRIER MAY BE HAZARDOUS. PROPER VENTILATION 
SHOULD BE PROVIDED IN ALL CASES BUT ESPECIALLY WHEN THE 
SURFACE TO BE EXAMINED IS INSIDE A CLOSED VOLUME. ENSURE 
GLOVES, SAFETY GLASSES AND PROTECTIVE CLOTHING ARE USED AND 
OBSERVE ALL NECESSARY SITE SAFETY PRECAUTIONS.
A. Thoroughly clean the area to be examined with a lint free cloth and cold degreasing fluid. 
Make sure that no cleaning fluid stays in surrounding pockets or comes into contact with 
electrical items, gaskets, seals etc. Allow to dry.
B. Apply the penetrant to the area to be examined by brushing, spray or swabbing. Minimum 
contact time shall be 60 minutes. Maximum cont act time shall be 120 minutes. However, 
make sure penetrant remains wet during the complete contact time.
APPENDIX - A
Nov 1/2014

### Page 8

Service Bulletin No. 32-17M 
Page 2
SERVICE BULLETIN
Messier-Dowty Ltd
C. Initially remove the excess penetrant with lint free cloths or paper towels, and then remove 
the remainder of the surface penetrant residues with solvent lightly-moistened lint free cloths 
or paper towels.
NOTE: Do not flush the area with solvent or saturate the lint free cloths or paper 
towels used to remove excess penetrant.
D. Make sure the surface is completely dry and apply the non-aqueous wet developer, 
ensuring a uniform thin coating is applied to the entire surface to be examined.
NOTE: Heavy or thick coatings of developer may mask small indications. Inspect 
the area immediately, to help identify developing indications, and again after 
the minimum development time. The minimum development time shall be 
10 minutes. The maximum development time shall be 60 minutes.
E. Use the black out cover as necessary to r educe the white light level and inspect using the 
UV-A inspection light. Allow a dark adaptation time of at least 2 minutes prior to inspection. 
Identify and report all relevant indications.
F. Post clean to remove all traces of developer and penetrant materials from the examined 
area.
APPENDIX - A
Nov 1/2014

### Page 9

Service Bulletin No. 32-17M
Page 1 of 2
CAGE: K0654
Cheltenham Road, Gloucester, GL2 9QH, England 
Telephone: +44 (0) 1452 712424 Fax: +44 (0) 1452 713821
SERVICE BULLETIN
Messier-Dowty Ltd
 ©MESSIER-BUGATTI-DOWTY 2014 (AND SUBSEQUENT REVISION PAGE DATES) 
This document and all information contained herein is the sole pr operty of Messier-Bugatti-Dowty. No intellectual property righ ts are 
granted by the delivery of this document or the disclosure of its content. This document shall not be reproduced to a third party without the 
express written consent of Messier-Bugatti-Dowty.
Safran and Messier-Bugatti names are marks owned respectively by  Safran and Messier-Bugatti-Dowty companies. The mark Dowty is 
used under licence.
APPENDIX - B
INSPECTION RESULTS PROFORMA FOR SB 32-17M
NOTE: Fill this profroma for every inspected Sliding Tube and send this form to 
pse.glostec@safranmbd.com.
AIRCRAFT SERIAL NO.: 
(IF APPLICABLE) 
TOTAL AIRFRAME HOURS AND 
CYCLES: 
OPERATOR NAME AND CONTACT 
DETAILS: 
NOSE LANDING 
GEAR DETAILS:
P/N
S/N
CSN
TSN
CSO
TSO
SLIDING TUBE 
DETAILS:
P/N
S/N
CSN
TSN
CSO
TSO
APPENDIX - B
Nov 1/2014

### Page 10

Service Bulletin No. 32-17M 
Page 2
SERVICE BULLETIN
Messier-Dowty Ltd
DATE OF DETAILED VISUAL 
INSPECTION (dd/mm/yy): 
 
FINDING OF DETAILED VISUAL 
INSPECTION: 
(If there are no adverse findings, this should 
be stated. If there are adverse findings, 
please include the details of dimensions 
and exact locations also attach 
photographic evidence.) 
 
DATE OF FLUORESCENT 
PENETRANT INSPECTION 
(dd/mm/yy): 
 
FINDING OF FLUORESCENT 
PENETRANT INSPECTION: 
(If there are no adverse findings, this should 
be stated. If there are adverse findings, 
please include the details of dimensions 
and exact locations also attach 
photographic evidence.) 
 
Nov 1/2014

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.