This text is OCR from a scan. OCR can misread letters and numbers. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1 (OCR)

DOC.NO
ETEMN  EASA.21J.250  SERVICE BULLETIN  P062-980092  REVISION: 00  PAGE 1 OF 2
ATA28 - Fuel- Non-conform fuel transfer pumps
The technical content of this document is approved
under the authority of DOA ref. EASA.21J.250.
SUBJECT:
Identification of non-conform fuel pumps - Operation Limitation
AFFECTED AIRPLANES:
Type: Stemme S10  TSA-M
Variant: Stemme S12  S6-RT
TCDS: EASA.A.054, GO6CE  EASA.A. 143
Serial Numbers: 12-057 up to and including 12-062  019, 029,030
TIME OF COMPLIANCE:
Before next flight
REASON:
A report on a leaking fuel transfer pump (P/N 830521), installed in the inner wing
(StemmeS 12) led to the identification of non-conform fuel pumps installed in aircrafts and
delivered as spare part under this part number.
IN  OUT
PET  NO.  HEP -02  IN -  → OUT
HKT  • CORPORATION  HEP-02A
NO
IN C  OUT
2/HEP - 02  MADE IN JAPAN
14B11
12/1/102
HKT HEP-02  HEP-02A (unknown manufacturer)
conform  non-conform
prepared  signature  verified  signature  Date of issue  supersedes  Office of Aiworthiness Date of approval
revision  relegsed
Rodenacker  Lengert  May 29, 2026  2 9. MAI 2026
FORM FEB-062, DATE OF ISSUE: 15JUL2024

### Page 2 (OCR)

DOC.NO
ETENME  SERVICE BULLETIN  P062-980092  REVISION: 00
EASA.21J.250  PAGE 2 OF 2
ACTIONS:
Verify the actual installed fuel pump type.
If non-conform fuel pumps (P/N 830521) are installed in the aircraft at the positions described
below the operation of the affected aircraft is prohibited.
Remark: Each aircraft consists two of this fuel pump.
STEMME S12  S6-RT
Remove the cover on the RH and LH side of  The two pumps are placed under the main
the bottom side of the inner wing. The pumps  spar of the inner wing. To inspect remove the
are placed behind the drainer.  RH and LH side cowling.
Position of covers
Fuel pump (RH side shown)
Inform the TC-holder if a non-conform pump is identified.
Note: If the inspection identifies the conform fuel pumps, no further action is required.
MATERIAL AND DOCUMENTS:
This Service Bulletin will be revised immediately after the availability of the correct fuel pump
туре.
Stemme will provide a replacement kit at the time. After modification, the operation
limitation will be suspended.
MASS AND BALANCE:
Not affected.
REMARKS:
For any question concerning the technical content of the requirements in this Service
Bulletin, please contact: STEMME GmbH, Flugplatzstrasse F2 Nr. 7, 15344 Strausberg,
GERMANY
Telephone: +49 3341 3612 0, E-mail: airworthiness[at]stemme.com
FORM FEB-062, DATE OF ISSUE: 15JUL2024

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.