# Zodiac Aerospace Service Bulletin 766983-28-002

Copy: Revision 1 ("U.S. DOT/FAA - SBI 766983-28-002 Rev1 Master"), 22 pages: PDF https://openairdocs.org/files/sha256/31/65/31659ae058f8055e690c6de7c7f497cd874aecbcc91a77f954afc77a480f9a6f; text https://openairdocs.org/service-documents/zodiac/sb-766983-28-002/file/31659ae058f8.md. Rights: © Zodiac Aerospace. Filed by the FAA in regulations.gov docket FAA-2014-0568; AD 2015-11-03 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.

## Details

- Manufacturer: [Zodiac](https://openairdocs.org/service-documents/zodiac.md) (issued as Zodiac Aerospace)
- Type: Service bulletin (Service Bulletin)
- Number: 766983-28-002
- Latest revision known: 766983-28-002, Revision 1, dated March 24, 2014 (OpenAirDocs)
- Page: https://openairdocs.org/service-documents/zodiac/sb-766983-28-002

## ADs that cite it (1) (OpenAirDocs)

Newest first, with the revision each names, as OpenAirDocs read it from the AD's text.

- [AD 2015-11-03](https://openairdocs.org/ad/2015-11-03.md), effective Jul 14, 2015: Revision 1

Also cited in [1 proposed AD](https://openairdocs.org/service-documents/zodiac/sb-766983-28-002/proposed.md).

## Text (22 pages)

Rights: © Zodiac Aerospace. Filed by the FAA in regulations.gov docket FAA-2014-0568; AD 2015-11-03 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication. Each page's text from the PDF; open the PDF at a page with #page=N.

### Page 1

ZODIAC AEROSPACE SERVICES EUROPE  
  
TECHNICAL PUBLICATION DEPARTMENT 
61, RUE PIERRE CURIE – CS20001 
78373 PLAISIR CEDEX - FRANCE 
Phone: +33 (0)1 61 34 19 24 - Fax: +33 (0)1 61 34 21 13 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No: 1 Page: 1/2
 
 
TRANSMITTAL SHEET 
 
This Transmittal Sheet applies to the issue 1, dated MAR 24/14, of Service Bulletin 
766983-28-002. 
 
REASON FOR REVISION 
Paragraph 1. A. (2) & Appendix I : P/N 768-055, 768-100,  798-038 instead of 768-055-0, 768-100-0,   
798-038-0. 
 
REVISION SEQUENCE 
Original Issue: OCT 15/13. 
Issue 1: MAR 24/14.

### Page 2

ZODIAC AEROSPACE SERVICES EUROPE  
  
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 2/2
 
 
PAGE LEFT BLANK INTENTIONALLY

### Page 3

ZODIAC AEROTECHNICS
SENSING SYSTEMS  
 SERVICE BULLETIN
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 1/20
 
 
TITLE: FUEL – FUEL PROB E – INSPECTION FOR POTENTIAL SPLICE CONDUCTOR 
SOLDERING DEFECT 
 
 
1. PLANNING INFORMATION 
A. Effectivity 
(1) Aircraft application 
This Service Bulletin applies to ATR 42/72 aircraft. 
(2) Equipment involved 
This Service Bulletin applies to Fuel Probes 766-046-2, 766-047-2, 766-048-2,   
766-793-1, 766-795-2, 766-796-2, 766-797-2, 766-983-1, 768-055, 768-100,   
798-038 listed in Appendix I, produced from June 2011 to August 2013 and not 
identified with letter “C” in the control box of the identification plate. 
B. Concurrent Requirements 
Affected customers should notify their usual Zodiac Aerospace Services contacts in 
regards of their location (See table 4. ZODIAC AEROSPACE SERVICES FACILITIES). 
C. Reason 
The purpose of this inspection is to check and repair if necessary the connection with 
splice conductor on the fuel probe. 
D. Description 
This inspection consists to check and repair if necessary the splice conductor connection 
on fuel probes. 
A discrepancy was found on the ground wire, due to a non-compliant soldering on the 
splice conductor. 
Letter “C” is applied on equipment once inspected (see paragraph  3. B. Identification). 
E. Compliance 
This inspection is RECOMMENDED.

### Page 4

ZODIAC AEROTECHNICS 
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 2/20
 
 
F. Approval 
The technical content of this document (rev.0) is approved under the Authority of DOA 
N°EASA. 21. J. 044. 
G. Manpower 
This Service Bulletin will be accomplished by Zodiac aircraft Sensing Systems 
Management (ZSSM) workshop within 15 working days from receipt of units. 
(1) 1 technician. 
(2) Check only: 1h00. 
(3) Complete operation: 1h45. 
H. Weight and Balance 
Not Changed. 
I. Electrical Load Data 
Not Changed. 
J. Software Accomplishment Summary 
Not Applicable. 
K. References 
CMM 28-42-72. 
L. Other Publications Affected 
Not changed. 
M. Interchangeability 
Not applicable.

### Page 5

ZODIAC AEROTECHNICS
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 3/20
 
 
2. MATERIAL INFORMATION 
A. Material – Price and Availability 
Application of this Service Bulletin  is Free of Charge for equipment produced from June 
2011 to August 2013, listed in Appendix I and not identified with letter “C” in the control 
box of the identification plate. 
B. Industry Support Information 
(1) The Service Bulletin can be accomplished by ZSSM workshop, the inspection will be 
done within 15 working days from receipt of equipment. 
C. Material Necessary for Each Component 
Not Applicable. 
D. Re-identified Parts 
Not applicable. 
E. Tooling – Price and Availability 
Not Applicable. 
3. ACCOMPLISHMENT INSTRUCTIONS 
A. Procedure 
CAUTION: Step n°(1) of this procedure is optional and leads to a time-saving in case of 
compliant splice conductor. If step n°(1) cannot be accomplished, do step n°(3). 
(1) Do an X-ray inspection of the splice conductor installed in the support assembly of 
the fuel probe. Then do step n° (2).

### Page 6

ZODIAC AEROTECHNICS 
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 4/20
 
(2) Do a check of the splice conductor soldering according to the following tables (in 
case of doubt, refer to step n°(3)): 
(a) If the splice conductor is compliant as described in table below, do step n°(7) 
for the final testing instructions. 
COMPLIANT SPLICE CONDUCTOR 
KEYPOINTS FIGURES 
Melted soldering 
aligned on stripped 
surface 
 
 
 
 
(b) If the splice conductor is not compliant as described in table below, do step 
n°(3) for the disassembly instructions.

### Page 7

ZODIAC AEROTECHNICS
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 5/20
 
NON-COMPLIANT SPLICE CONDUCTOR 
KEYPOINTS FIGURES 
Level 1 defect: 
Soldering not aligned 
on the stripped surface 
 
Level 1 defect: 
Soldering is not melted 
 
Level 1 defect: 
Missing soldering

### Page 8

ZODIAC AEROTECHNICS 
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 6/20
 
NON-COMPLIANT SPLICE CONDUCTOR 
KEYPOINTS FIGURES 
Level 2 defect: 
Partially melted soldering 
 
 
(3) Disassemble the fuel probe according to the following steps and tables: 
TOOLS CONSUMABLES 
Hot air tool with digital display 
(STEINEL HG 2310 or equivalent), 
with reduction nozzle (STEINEL 
n°070618 or equivalent) 
Beveled branchwood stick 
Ø4mm. 
Flat-blade screwdriver 3.5x100 or 
equivalent 
--- 
 
(a) Soften glue with hot air tool to get access to the screws of the clamp. 
KEYPOINTS FIGURE 
T°C=300°C 
Airflow = mini

### Page 9

ZOD
SENSING S
Date: MA
Revision
 
 
DIAC AE
SYSTEMS 
AR 24/14 
n No. 1 
(b) 
(c) 
(d) 
EROTEC
S
Strip glue
K
Risk of s
clamp 
Loosen th
Use the h
clamp. 
K
Risk of s
clamp 
 
CHNICS
SERVICE B
e with branc
KEYPOINT
scratching o
he four scre
hot air tool a
KEYPOINT
scratching o
 
BULLETIN
chwood stic
on the 
ews and wa
and branchw
on the 
N: 
k. 
shers and r
wood stick 
7669
FIG
remove the 
to remove t
FIG
983-2
GURE 
clamp. 
the remaini
GURE 
28-00
Page: 
ng glue on 
02
7/20
 
 
the

### Page 10

Z
SE
Da
Re
 
 
ZODIAC
ENSING SYSTEMS
ate: MAR 24/
evision No. 1
(4) 
C AEROT
S 
/14 
1 
Do a visu
steps and 
Binocula
magnifyi
Binocula
magnifyi
equivale
(a) If th
step
- T
(rin
con
dis
sol
bet
the
- T
gro
(B)
 
(b) If th
n°(5
TECHNI
SERVI
al inspectio
tables: 
TOOLS 
ar microscop
ng lamp or 
KEYPOINT
ar microscop
ng lamp or 
nt 
e splice co
p n°(6) for th
KEYPOI
The solde
ng) is fully m
ntour 
cernable, 
der is 
tween the s
e ground wir
The shield
ound wire a
). 
e splice c o
5) for the rew
ICS 
ICE BULL
on of the s p
pe or 
equivalent
T 
pe or 
nductor sol
he assembly
COM
NTS 
r preform 
melted, its 
is no 
a fillet of 
visible 
shield and 
re (A). 
 and the 
are aligned 
onductor is 
wiring instru
NOT CO
 
LETIN: 
plice condu
ldering is c
y instruction
MPLIANT SP
not complia
uctions. 
OMPLIANT
76
ctor solderi
CONS
ompliant as
ns. 
PLICE CON
ant as des c
T SPLICE C
66983
ing, accord
SUMABLES
N/A 
FIGURE 
s described
NDUCTOR 
FIGURE 
cribed in t a
ONDUCTO
3-28-
P
ing to the f
S 
d in table b e
able below, 
OR 
-002
Page: 8/20
 
following 
elow, do 
do step

### Page 11

ZOD
SENSING S
Date: MA
Revision
 
 
DIAC AE
SYSTEMS 
AR 24/14 
n No. 1 
(5) Do a
TO
Ho
231
(ST
So
The
Cu
EROTEC
S
K
In case
to 
a rewiring a
OOLS 
t air tool wit
10 or equiva
TEINEL n°0
ldering iron
ermal wire s
tting pliers 
 
CHNICS
SERVICE B
EYPOINT 
e of doubt, r
step n°(5).
ccording to
th digital dis
alent), with 
074616 or e
METCAL w
stripper (PB
 
BULLETIN
refer 
o the followin
splay (STEI
angled noz
quivalent) 
with thin-tip 
B150M or eq
N: 
ng steps an
NEL HG 
zzle 
STTC-036
quivalent) 
7669
FIGU
nd tables. 
CO
Desold
Groun
Splice c
Solder
983-2
URE 
ONSUMAB
dering braid
nd wire W10
conductor W
r W192456 
28-00
Page: 
LES 
d 
04476 
W192116 
02
9/20

### Page 12

ZODIAC AEROTECHNICS 
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 10/20
 
 
(a) Desolder the core of the coaxial cable (HI) from the connector and the ground 
wire (M) from the lug. 
KEYPOINT FIGURE 
Remove the red caps from 
the connectors. 
 
(b) Remove the coaxial cable from the support assembly. 
(c) Cut the coaxial cable very close to the splice conductor and discard the 
excess. 
KEYPOINT FIGURE 
Cutting very close to the splice 
conductor. 
 
(d) Remove the remaining solder from the lug of the ground wire and from the 
connector receptacle. 
(e) Strip off 25mm of the first insulation of the coaxial cable. 

HI 
M

### Page 13

ZODIAC AEROTECHNICS
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 11/20
 
KEYPOINT FIGURE 
Stripping = 25mm 
 
(f) Retract the braid to the maximum. 
FIGURE 
 
(g) Cut the braid. 
KEY POINT FIGURE 
Do not damage the second 
insulation.

### Page 14

ZODIAC AEROTECHNICS 
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 12/20
 
(h) Strip off 5mm of the first insulation again. 
KEYPOINT FIGURE 
Stripping = 5mm 
(i) Strip and tin the new ground wire W104476. 
KEYPOINTS FIGURE 
- Length = 50mm 
- Stripping = 5mm 
(j) Hold the ground wire on the coaxial cable and solder it very lightly. 
KEYPOINTS FIGURE 
- Insulations of the two 
cables are aligned. 
- The least possible 
soldering 
(k) Install the splice conductor on the stripped portion of the wire: 
KEYPOINTS FIGURE 
- Solder ring centered. 
- The two cables inserted in 
the largest splice conductor 
diameter. 
 
  
Ø large

### Page 15

ZOD
SENSING S
Date: MA
Revision
 
DIAC AE
SYSTEMS 
AR 24/14 
n No. 1 
(l) 
(m) 
(n) 
EROTEC
S
Prepare t
K
- Angled
n°07461
- T°C=38
- Airflow
- Prehea
Solder the
- Splice 
with the 
- Ring ce
surfaces
- Duratio
- Hot air 
oriented
Make sur
table belo
K
- The so
melted, 
discerna
is visible
shielder 
(A). 
- The sh
ground w
 
 
CHNICS
SERVICE B
the hot air to
KEYPOINTS
d nozzle ST
6 or equiva
80°. 
=mini. 
ating >1min
e splice con
KEYPOINT
conductor i
top of the n
entered in t
s. 
on : minimu
tool horizo
. 
re that the s
ow: 
KEYPOINT
older preform
its contour 
able, a fillet 
e between th
and the gro
ielder and t
wire are alig
 
BULLETIN
ool: 
S 
EINEL 
alent. 
. 
nductor: 
TS 
n contact 
nozzle. 
he stripped
m of 18 s.
ntally-
splice condu
TS 
m is fully 
is no 
of solder 
he 
ound wire 
the 
gned (B). 
N: 
 
uctor solde
7669
FIG
F
ring is comp
FIG
983-2
GURE 
FIGURE 
pliant as de
GURE 
28-00
Page: 1
escribed in 
02
3/20
 
 
the

### Page 16

ZODIAC AEROTECHNICS 
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 14/20
 
 
(o) Cut to length, strip and tin the ground wire (M) and the high impedance coaxial 
cable core (HI). 
KEYPOINT FIGURE 
Stripping: 5mm. 
(p) Solder the ground wire (M) on the lug of the support assembly. 
FIGURE 
 
 
  
M 
HI

### Page 17

ZODIAC AEROTECHNICS
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 15/20
 
 
(q) Solder the cable of high impedance (HI) on the connector receptacle. 
FIGURE 
 
(r) Make sure that the solderings are compliant. 
(s) Blow compressed air on the fuel probe. Make sure that there is no solder 
splatter into the clamp.

### Page 18

ZODIAC AEROTECHNICS 
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 16/20
 
 
(6) Assemble the fuel probe according to the following steps and tables. 
TOOLS  CONSUMABLES QTY 
Flat-blade screwdriver 
3.5x100 or equivalent 
Screw G225032 4 
Point 7M14339-7M14340 
or equivalent 
Lock washer G772120 4 
--- Araldite 2011 (base 
2011/A=W192355 + hardener 
2011/B=W195356) 
1 
--- Clamp A791278 (if non-reusable) 1 
--- Cap G899087D7 2 
--- 95° Denaturized Ethylic Alcohol 1 
--- Cotton-swab 1 
 
(a) Tighten the 4 screws with the 4 lock washers on the clamp A791278. 
KEYPOINTS FIGURES 
- Do not reuse the initial 
screws. 
- Change the clamp if it is 
scratched. 
 
 
(b) Use a cotton-swab moistened with 95° Denaturized Ethylic Alcohol to remove 
the grease from the clamp. 
(c) Prepare a base-hardener mixture of Araldite. 
KEYPOINTS FIGURE

### Page 19

ZODIAC AEROTECHNICS
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 17/20
 
- Proportion by weight: 
Base 2011/A: 100 p.p. 
Hardener 25011/B: 80p.p. 
- Use of the mixture: 2h max. 
 
(d) Apply Araldite on the screw heads. 
(e) Remove any excess with a lint-free cloth. 
(f) Let polymerising at ambient temperature during a minimum of 8 hours. 
(7) Final testing 
Do the final testing of the fuel probe in accordance with "TESTING AND FAULT 
ISOLATION" chapter of CMM 28-42-72.

### Page 20

Z
SE
Da
Re
 
ZODIAC
ENSING SYSTEMS
ate: MAR 24/
evision No. 1
B. Iden t
(1) 
 
(2) 
C AEROT
S 
/14 
1 
 
tification 
After inspe
plate acco
TO
Punch w
M
KE
Light mal
Letter “C”
left side o
stamp. 
Install the 
TECHNI
SERVI
ection, app
ording to the
OOLS 
with letter “C
Mallet 
EYPOINTS 
let blows 
” on the righ
of the contro
protection 
 
ICS 
ICE BULL
ly letter “C ”
e following t
QTY
C” 1 
1 
ht or 
ol 
caps on the
 
LETIN: 
” on the “C o
tables: 
CONSUM
Cap G899
---
e 2 connect
76
ontrol” box 
MABLES 
9087D7 
- 
FIG
tors. 
66983
of the fuel 
QTY
2 
--- 
GURES 
3-28-
Pa
probe iden
-002
age: 18/20
 
tification

### Page 21

ZODIAC AEROTECHNICS
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 19/20
 
 
4. ZODIAC AEROSPACE SERVICES FACILITIES 
EUROPE ASIA 
ZODIAC AEROSPACE SERVICES EUROPE 
61 rue Pierre Curie 
CS20001  
78373 PLAISIR Cedex  
France 
Phone : +33 61 34 23 23 
FAX : + 33 1 61 34 21 13 
ZODIAC AEROSPACE SERVICES ASIA 
36, Loyang Drive 
SINGAPORE 508949 
Phone : +65 6579 2230 
Fax : +65 6579 2231 
 
AMERICAS 
ZODIAC AEROSPACE SERVICES AMERICAS
W175 N5737 Technology Drive 
MENOMONEE FALLS, WI 53051 
USA 
Phone : +1 262 293 1000 
FAX : +1 262 293 1010 
Web site: www.zodiacaerospace.com

### Page 22

ZODIAC AEROTECHNICS 
SENSING SYSTEMS 
 
Date: MAR 24/14 SERVICE BULLETIN: 766983-28-002
Revision No. 1 Page: 20/20
 
APPENDIX I 
 
This Service Bulletin applies to fuel probes produced from June 2011 to August 2013, not identified 
with letter “C” in the control box of the identification plate, and listed as follows: 
 
 
 
Aircraft Equipment PNR First S/Ns Last S/Ns 
42 766-046-2 1046 1083 
42 766-047-2 1154 1214 
42 766-048-2 1150 1197 
42 768-055 1156 1227 
42 798-038 1150 1238 
72 766-793-1 1469 1826 
72 766-795-2 1661 2093 
72 766-796-2 1722 2152 
72 766-797-2 1663 2051 
72 766-983-1 2200 2652 
72 768-100 1511 1876

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.