# TCDS A15CE: Balloonacy LLC

- Type: Type certificate data sheet
- Status: Current
- Holder: Balloonacy LLC
- Revision: 45
- Revised: December 6, 2021
- Product: Aircraft, Balloon
- Certification basis: Part 31
- Registered aircraft: 974, by the registry models matched to it (OpenAirDocs)
- Data sheet PDF: https://openairdocs.org/files/sha256/60/8d/608d973848ba1fecaf4da13055bbe9652ba42ad6e4c43158a5122e822b3a64c9
- FAA DRS: https://drs.faa.gov/browse/excelExternalWindow/B214A08E9A87CF348625881A005CFBE3.0001
- Page: https://openairdocs.org/tcds/A15CE

## Models (49)

As the data sheet lists them.

- DAISY
- SPIII
- CTS
- S-49A
- S-52A
- S-60H
- RX-9
- 110P
- CAKE
- S-60S
- S-57A
- SPII
- S-71A
- S-57H
- CELL
- S-51A
- S-77A
- ARKY
- S-81A
- BAG
- RX-8
- PCORN
- SPI
- S-53H
- COOK
- W100LB
- RX-6
- S-55A
- S-57S
- RXS-8
- BRAIN
- QUBE-80
- 110C
- BUNY
- BRUT
- S-60A
- S-64A
- S-40A
- BEAR
- SUN
- 78C
- 90C
- S-50A
- S-53A
- HOUSE
- GEOSPHERE
- RX-7
- S-66A
- PNUT

## What the data sheet says

Some pages are OCR from the scanned FAA data sheet. OCR can misread letters and numbers.

```text
DEPARTMENT OF TRANSPORTATION 
FEDERAL AVIATION ADMINISTRATION 
 
   A15CE 
   Revision 45 
   AEROSTAR 
   (RAVEN) 
 RX-6 S-60A BRUT 
 RX-7 S-60H BUNY 
 RX-8 S-60S CAKE 
 RXS-8 S-64A CELL 
 RX-9 S-66A COOK 
 S-40A S-71A CTS 
 S-49A S-77A DAISY 
 S-50A S-81A GEOSPHERE 
 S-51A 78C HOUSE 
 S-52A 90C PCORN 
 S-53A 110C PNUT 
 S-53H 110P QUBE-80 
 S-55A ARKY SPI 
 S-57A BAG SPII 
 S-57H BEAR SPIII 
 S-57S BRAIN SUN 
  W100LB 
December 6, 2021 
TYPE CERTIFICATE DATA SHEET NO. A15CE 
This data sheet, which is part of Type Certificate No. A15CE, prescribes conditions and limitations under which the product for 
which the type certificate was issued meets the airworthiness requirements of the Federal Aviation Regulations. 
 
Type Certificate Holder: Balloonacy, LLC 
 125 Redwood Circle 
 Fayetteville, GA 30214 
 
Type Certificate Holder Record: Aerostar International, Inc. transferred TC A15CE to  
 Balloonacy, LLC on December 6, 2021 
 
 Raven Industries transferred TC A15CE to Aerostar 
International, Inc. on February 1, 1986 
 
I  - Model S-50A, Hot Air Balloon, Approved December 10, 
1968 Envelope Aerostar Drawing 05957 
Air Heaters Aerostar P/N 04420, 10118, 12323, 13050, 13155, 13180, 14160, 14170, 15370, 15384, 17395, 
17398, 17399, 17400, 17642, 51464, 52350, or 52370 (see NOTE 7). 
Gondolas G Series (aluminum), Drawing 01919; Model W (wicker), Drawing 12717; 
G Series H.P. (aluminum), Drawing 12570; Model W, H.P. (wicker), Drawing 12560; G Series 
H.P. high control (aluminum), Drawing 13843; Model W, H.P. high control (wicker), Drawing 
13842; Model CW (wicker), Drawing 13860; Model RW (wicker), Drawing 14530; Model CW-V 
(wicker), Drawing 15325; Model RWS (wicker), Drawing 52131; Model ELS (wicker), Drawing 
52440; Model ELSS (wicker), Drawing 53095; Model RWSW (wicker), Drawing 53030; Model 
CW-AFX (wicker), Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
Maximum Weight  For Model ELS gondola, Drawing 52440, and Model ELSS gondola, Drawing 53095, the gross 
weight limited to 1150 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1400 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. see Balloon Flight Manual. 
 
Page No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 
Rev. No. 45 45 31 31 31 36 41 31 31 31 41 33 33 41 33 33 33 42 42 
Page No. 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36  
Rev. No. 33 33 33 33 33 33 35 37 39 40 41 41 44 44 44 42 44

A 15 CE  2 of 37 
 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860 and Model CW-AFX (wicker), Drawing 53160, fuel 
capacity is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 
tanks; or two or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two H-20 tanks; or two or three or four 
V-10 tanks; or two or three or four V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S50A-124 and up (see NOTE 1 for S/N S50A-121 through 123, also see NOTE 2). 
II - Model S-40A, Hot Air Balloon, Approved July 15, 1969 
Envelope Aerostar Drawing 06275 
Air Heater Aerostar P/N 09645 (see NOTE 7). 
Gondola G Series (aluminum), Drawing 01919; Model ELS (wicker), Drawing 52440; or Model ELSS 
(wicker), Drawing 53095. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 800 lbs. or to weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or two V-15 tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For all other approved gondolas, fuel capacity is limited to two V-10 tanks; or two V-15 tanks (see 
NOTE 6). 
Serial Nos. 
Eligible S40A-114, -116 and up (see NOTE 2). 
III - Model S-60A, Hot Air Balloon, Approved April 30, 1971 
Envelope Aerostar Drawing 10428 
Air Heaters Aerostar P/N 10118, 12323, 13050, 13155, 13180, 14160, 14170, 15370, 15384, 17395, 17398, 
17399, 17400, 17642, 51464. 52350, or 52370 (see NOTE 7).

3 of 37 A15CE 
 
Gondolas G Series (aluminum), Drawing 01919; Model W (wicker), Drawing 12717; 
G Series H.P. (aluminum), Drawing 12570; Model W, H.P. (wicker), Drawing 12560; G Series 
H.P. high control (aluminum), Drawing 13843; Model W, H.P. high control (wicker), Drawing 
13842; Model CW (wicker), Drawing 13860; Model RW (wicker), Drawing 14530; Model CW-V 
(wicker), Drawing 15325; Model CW-S (wicker), Drawing 51620; Model RWS (wicker), Drawing 
52131; Model RWSW (wicker), Drawing 53030; Model CW-AFX (wicker), Drawing 53160; or 
Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
Maximum Weight For Model CW gondola, Drawing 13860; Model CW-V gondola, Drawing 15325, Model CW-S 
gondola, Drawing 51620, Model RWS gondola, Drawing 52131, Model RWSW gondola, Drawing 
53030, Model CW-AFX (wicker), Drawing 53160, and Model RWSW-AFX (wicker), Drawing 
53130, when used with either H.P. Dual Burner, Drawing 14160, H.P. II Dual Burner, Drawing 
17395, or H.P. III Dual Burner, Drawing 52350, the gross weight limited to 1800 lbs. or to the 
weight requiring maximum continuous envelope temperature of 250oF., whichever is less. See 
Balloon Flight Manual. 
 
For all other approved burner and gondola combinations, the gross weight limited to 1470 lbs. or to 
the weight requiring maximum continuous envelope temperature of 250oF., whichever is less. see 
Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, Model CW-S gondola, Drawing 51620, and Model 
CW-AFX (wicker), Drawing 53160, fuel capacity is limited to two H-20 tanks; or one H-20 tank 
and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 tanks 
(see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two H-20 tanks; or two or three or four 
V-10 tanks; or two or three or four V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S60A-105 and up (see NOTE 2). 
IV - Model S-55A, Hot Air Balloon, Approved April 10, 1973 
Envelope Aerostar Drawing 11813 
Air Heaters Aerostar P/N 10118, 12323, 13050, 13155, 13180, 14160, 14170, 15370, 15384, 17395, 17398, 
17399, 17400, 17642, 51464, 52350, or 52370 (see NOTE 7). 
Gondolas G Series (aluminum), Drawing 01919; Model W (wicker), Drawing 12717; 
G Series H.P. (aluminum), Drawing 12570; Model W, H.P. (wicker), Drawing 12560; G Series 
H.P. high control (aluminum), Drawing 13843; Model W, H.P. high control (wicker), Drawing 
13842; Model CW (wicker), Drawing 13860; Model RW (wicker), Drawing 14530; Model CW-V 
(wicker), Drawing 15325; Model RWS (wicker), Drawing 52131; Model ELS (wicker), Drawing 
52440; Model ELSS (wicker), Drawing 53095; Model RWSW (wicker), Drawing 53030; Model 
CW-AFX (wicker), Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
Maximum Weight  For Model ELS gondola, Drawing 52440, and Model ELSS gondola, Drawing 53095, the gross 
weight limited to 1200 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1435 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. see Balloon Flight Manual.

A 15 CE  4 of 37 
 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-AFX (wicker), Drawing, fuel capacity is 
limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two or 
three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two H-20 tanks,; or two or three or four 
V-10 tanks; or two or three or four V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S55A-101 thru S55A-103, S55A-105 thru S55A-114, S55A-116 and up. (See NOTE 2.) 
V - Model RX-6, Hot Air Balloon, Approved September 10, 1974 
Envelope Aerostar Drawing 12600 
Air Heaters Aerostar P/N 13180, 51464, 17395, 17398, 17399, 52350, or 52370 (see NOTE 7). 
Gondola  Model R (polyethylene), Drawing 12580; Model RW (wicker), Drawing 14530; 
Model RWS (wicker), Drawing 52131; Model ELS (wicker), Drawing 52440; 
Model ELSS (wicker), Drawing 53095; Model RWSW (wicker), Drawing 53030; or Model 
RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
Maximum Weight For Model ELS gondola, Drawing 52440, and Model ELSS gondola, Drawing 53095, the gross 
weight limited to 1150 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1430 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot.

5 of 37 A15CE 
 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 tanks; or two 
or three or four V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible RX6-101 and up (see NOTE 2). 
VI - Model RX-7, Hot Air Balloon, Approved November 21, 1978 
Envelope Aerostar Drawing 17312 
Air Heaters Aerostar P/N 13180, 14160, 14170, 17395, 17398, 17399, 51464, 52350, or 52370 (see NOTE 7). 
 
Gondola Model R (polyethylene), Drawing 12580; Model RW (wicker), Drawing 14530; 
Model RWS (wicker), Drawing 52131; Model CW (wicker), Drawing 13860; 
Model CW-V (wicker), Drawing 15325; Model ELS (wicker), Drawing 52440; 
Model ELSS (wicker), Drawing 53095; Model RWSW (wicker), Drawing 53030; 
Model CW-AFX (wicker), Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight For Model ELS gondola, Drawing 52440, and Model ELSS gondola, Drawing 53095, the gross 
weight limited to 1200 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1480 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-AFX (wicker), Drawing 53160, fuel 
capacity is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 
tanks; or two or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two H-20 tanks; or two or three or four 
V-10 tanks; or two or three or four V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible RX7-101 and up (see NOTE 2).

A 15 CE  6 of 37 
 
VII - Model S-66A, Hot Air Balloon, Approved September 19, 1979 
Envelope Aerostar Drawing 17653 
Air Heaters Aerostar P/N 14160, 17395, 52350, or 52950 (see NOTE 7). 
Gondolas G Series H.P. high control (aluminum), Drawing 13843; Model W, H.P. high control (wicker), 
Drawing 13842; Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; 
Model TW, Drawing 51076; or Model CW-S (wicker), Drawing 51620; or Model RB6, Drawing 
52428; Model RB5, Drawing 52805; or Model CW-AFX (wicker), Drawing 53160. 
Fuel Commercial LPG 
Maximum Weight For Model W gondola, H.P. high control, Drawing 13842, and for G Series gondola, H.P. high 
control, Drawing 13843, the gross weight limited to 1590 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. See Balloon Flight Manual. 
For Model CW gondola, Drawing 13860, Model CW-V gondola, Drawing 15325, Model CW-S 
gondola, Drawing 51620, and; Model CW-AFX (wicker), Drawing 53160, the gross weight limited 
to 2,000 lbs. or to the weight requiring maximum continuous envelope temperature of 250oF., 
whichever is less. See Balloon Flight Manual. 
 
For Model RB5 gondola, Drawing 52805, the gross weight limited to 2,300 lbs. or to the weight 
requiring maximum continuous envelope temperature of 250oF., whichever is less. See Balloon 
Flight Manual. 
 
For Model TW gondola, Drawing 51076, or Model RB6 gondola, Drawing 52428, the gross weight 
limited to 2500 lbs. or to the weight requiring maximum continuous envelope temperature of 
250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model TW gondola, Drawing 51076, fuel capacity is limited to six V-10 tanks; or four V-15 
tanks (see NOTE 6). 
 
For Model RB6 gondola, Drawing 52428, fuel capacity is limited to two V-23 tanks; or two V-23 
tanks and one or two V-15 or V-18 tanks; or three or four V -15 or V-18 tanks. When used with a 
triple burner, a minimum of three tanks is required (see NOTE 6). 
 
For Model RB5 gondola, Drawing 52805, fuel capacity is limited to three V-15 tanks; or two V-18 
tanks and one V-15 tank (see NOTE 6). 
For Model CW gondola, Drawing 13860, Model CW-S gondola, Drawing 51620, and 
Model CW-AFX (wicker), Drawing 53160, fuel capacity is limited to two H-20 tanks; or one H-20 
tank and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 
tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two H-20 tanks; or three or four V-10 
tanks; or two or three or four V-15 tanks (see NOTE 6). 
Serial Nos. 
Eligible S66A-102 and up (see NOTES 1 and 2). 
VIII - Model W100LB, Hot Air Balloon, Approved April 16, 1980 
Envelope Aerostar Drawing 51072 
Air Heaters Aerostar P/N 14160, 14170, 15384, 17395, 17398, or 17642 (see NOTE 7). 
 
Gondola Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; or 
Model CW-AFX (wicker), Drawing 53160. 
Fuel Commercial LPG

7 of 37 A15CE 
 
Maximum Weight Gross weight limited to 1200 lbs. or to weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity Two H-20 tanks; or three or four V-10 tanks (see NOTE 6). 
Serial Nos. 
Eligible W100LB-101 and up (see NOTE 2). 
IX - Model S-77A, Hot Air Balloon, Approved May 11, 1983 
Envelope Aerostar Drawing 51502 
Air Heaters Aerostar P/N 14160, 17395, 52350, or 52950 (see NOTE 7). 
Gondolas Model TW, Drawing 51076 (with Dual burners only); or Model RB6, Drawing 52428; or Model 
RB8, Drawing 52430; or Model RB12, Drawing 52430-02. 
Fuel Commercial LPG 
Maximum Weight For Model RB8 gondola, Drawing 52430, and Model RB12 gondola, Drawing 52430-02, the gross 
weight limited to 3450 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. Envelope revision letter must be 
Revision S or higher, or retrofitted with Revision S or higher to qualify 
 
For all other gondolas, the gross weight limited to 2800 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model TW gondola, Drawing 51076, fuel capacity is limited to six V-10 tanks; or four V-15 
tanks (see NOTE 6). 
 
For Model RB6 gondola, Drawing 52428, fuel capacity is limited to two V-23 tanks; or two V-23 
tanks and one or two V-15 or V-18 tanks; or three or four V -15 or V-18 tanks. When used with a 
triple burner, a minimum of three tanks is required (see NOTE 6). 
 
For Model RB8 gondola, Drawing 52430, and Model RB12 gondola, Drawing 52430-02, fuel 
capacity is limited to three V-23 tanks; or two V-23 tanks and one or two or three V-15 or V-18 
tanks; or three or four or five V-15 or V-18 tanks (see NOTE 6). 
Serial Nos. 
Eligible S77A-101 and up (see NOTES 1 and 2). 
X - Model S-57A, Hot Air Balloon, Approved June 19, 1987 
Envelope Aerostar Drawing 52057 
Air Heaters Aerostar P/N 10118, 12323, 13050, 13155, 13180, 14160, 14170, 15370, 15384, 17395, 17398, 
17399, 17400, 17642, 51464, 52350, or 52370 (see NOTE 7). 
Gondolas G Series (aluminum), Drawing 01919; Model W (wicker), Drawing 12717; 
G Series H.P. (aluminum), Drawing 12570; Model W, H.P. (wicker), Drawing 12560; G Series 
H.P. high control (aluminum), Drawing 13843; Model W, H.P. high control (wicker), Drawing 
13842; Model CW (wicker), Drawing 13860; Model RW (wicker), Drawing 14530; Model CW-V 
(wicker), Drawing 15325; Model CW-S (wicker), Drawing 51620; Model RWS (wicker), Drawing 
52131; Model ELS (wicker), Drawing 52440; Model ELSS (wicker), Drawing 53095; 
Model RWSW (wicker), Drawing 53030; Model CW-AFX (wicker), Drawing 53160; or Model 
RWSW-AFX (wicker), Drawing 53130.

A 15 CE  8 of 37 
 
Fuel Commercial LPG 
Maximum Weight  For Model CW gondola, Drawing 13860, Model CW-V gondola, Drawing 15325, Model CW-S 
gondola, Drawing 51620, Model RWS gondola, Drawing 52131; Model RWSW gondola, Drawing 
53030, Model CW-AFX (wicker), Drawing 53160, and Model RWSW-AFX (wicker), Drawing 
53130, when used with either H.P. Dual Burner, Drawing 14160, H.P. II Dual Burner, Drawing 
17395, or H.P. III Dual Burner, Drawing 52350, the gross weight limited to 1650 lbs. or to the 
weight requiring maximum continuous envelope temperature of 250oF., whichever is less. See 
Balloon Flight Manual. 
 
For Model ELS gondola, Drawing 52440, and Model ELSS gondola, Drawing 53095, the gross 
weight limited to 1200 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1455 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, Model CW-S gondola, Drawing 51620, and Model 
CW-AFX (wicker), Drawing 53160, fuel capacity is limited to two H-20 tanks; or one H-20 tank 
and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 tanks 
(see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two H-20 tanks; or two or three or four 
V-10 tanks; or two or three or four V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S57A-3001 and up. (See NOTE 2.) 
XI - Model S-52A, Hot Air Balloon, Approved April 26, 1988 
Envelope Aerostar Drawing 52052 
Air Heaters Aerostar P/N 04420, 10118, 12323, 13050, 13155, 13180, 14160, 14170, 15370, 15384, 17395, 
17398, 17399, 17400, 17642, 51464, 52350, or 52370 (see NOTE 7). 
Gondolas G Series (aluminum), Drawing 01919; Model W (wicker), Drawing 12717; 
G Series H.P. (aluminum), Drawing 12570; Model W, H.P. (wicker), Drawing 12560; G Series 
H.P. high control (aluminum), Drawing 13843; Model W, H.P. high control (wicker), Drawing 
13842; Model CW (wicker), Drawing 13860; Model RW (wicker), Drawing 14530; Model CW-V 
(wicker), Drawing 15325; Model RWS (wicker), Drawing 52131; Model ELS (wicker), Drawing 
52440; Model ELSS (wicker), Drawing 53095; Model RWSW (wicker), Drawing 53030; Model 
CW-AFX (wicker), Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG

9 of 37 A15CE 
 
Maximum Weight For Model ELS gondola, Drawing 52440, and Model ELSS gondola, Drawing 53095, the gross 
weight limited to 1150 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1400 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-AFX (wicker), Drawing 53160, fuel 
capacity is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 
tanks; or two or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two H-20 tanks; or two or three or four 
V-10 tanks; or two or three or four V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S52A-3001 and up (see NOTE 2). 
XII - Model RX-8, Hot Air Balloon, Approved May 8, 1989 
Envelope Aerostar Drawing 52088 
Air Heaters Aerostar P/N 13180, 14160, 14170, 17395, 17398, 17399, 51464, 52350, or 52370 (see NOTE 7). 
Gondola Model R (polyethylene), Drawing 12580; Model RW (wicker), Drawing 14530; Model 
RWS (wicker), Drawing 52131; Model CW (wicker), Drawing 13860; Model CW-V (wicker), 
Drawing 15325; Model CW-S (wicker), Drawing 51620; Model ELS (wicker), Drawing 52440; 
Model ELSS (wicker), Drawing 53095; Model RWSW (wicker), Drawing 53030; Model CW-AFX 
(wicker), Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
Maximum Weight  For Model RWS gondola, Drawing 52131; model CW gondola, Drawing 13860; Model CW-V 
gondola, Drawing 15325; Model CW-S gondola, Drawing 51620; Model RWSW gondola, 
Drawing 53030, Model CW-AFX (wicker), Drawing 53160, and Model RWSW-AFX (wicker), 
Drawing 53130, when used with either H.P. Dual Burner, Drawing 14160, H.P. II Dual Burner, 
Drawing 17395, or H.P. III Dual Burner, Drawing 52350, the gross weight limited to 1650 lbs. or 
to the weight requiring maximum continuous envelope temperature of 250oF., whichever is less. 
See Balloon Flight Manual. 
 
For Model ELS gondola, Drawing 52440, and Model ELSS gondola, Drawing 53095, the gross 
weight limited to 1200 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1480 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. see Balloon Flight Manual.

A 15 CE  10 of 37 
 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, Model CW-S gondola, Drawing 51620, and Model 
CW-AFX (wicker), Drawing 53160, fuel capacity is limited to two H-20 tanks; or one H-20 tank 
and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 tanks 
(see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two H-20 tanks; or two or three or four 
V-10 tanks; or two or three or four V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible RX8-3001 and up (see NOTE 2). 
XIII - Model 78C, Hot Air Balloon, Approved May 8, 1989 
Envelope Aerostar Drawing 51989 
Air Heaters Aerostar P/N 13050, 14160, 17395, or 52350 (see NOTE 7). 
Gondola Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model RWS 
(wicker), Drawing 52131; Model RWSW (wicker), Drawing 53030; Model CW-AFX (wicker), 
Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1400 lbs. or to weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-AFX (wicker), Drawing 53160, fuel 
capacity is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 
tanks; or two or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible 78C-3001 and up (see NOTE 2).

11 of 37 A15CE 
 
XIV - Model 90C, Hot Air Balloon, Approved July 8, 1989 
Envelope Aerostar Drawing 51990 
Air Heaters Aerostar P/N 13050, 14160 17395, or 52350 (see NOTE 7). 
Gondola Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model 
RWS (wicker), Drawing 52131; Model CW-S (wicker), Drawing 51620; Model RWSW (wicker), 
Drawing 53030; Model CW-AFX (wicker), Drawing 53160; or Model RWSW-AFX (wicker), 
Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1500 lbs. or to weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, Model CW-S gondola, Drawing 51620, and Model 
CW-AFX (wicker), Drawing 53160, fuel capacity is limited to two H-20 tanks; or one H-20 tank 
and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 tanks 
(see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible 90C-3001 and up (see NOTE 2). 
XV - Model CTS, Hot Air Balloon, Approved October 6, 1989 
Envelope Aerostar Drawing 52393 
Air Heaters Aerostar P/N 13050, 14160, 17395, or 52350 (see NOTE 7). 
Gondola  Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; or Model RWS 
(wicker), Drawing 52131; Model RWSW (wicker), Drawing 53030; Model CW-AFX (wicker), 
Drawing 53160; Model RWSW-AFX (wicker), Drawing 53130; Model ELS (wicker), Drawing 
52440; or Model ELSS (wicker), Drawing 53095. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1450 lbs. or to weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot.

A 15 CE  12 of 37 
 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-AFX (wicker), Drawing 53160, fuel 
capacity is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 
tanks; or two or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible CTS-3001 and up (see NOTE 2). 
XVI - Model S-71A, Hot Air Balloon, Approved August 24, 1990 
Envelope Aerostar Drawing 52071 
Air Heaters Aerostar P/N 14160, 17395, 52350, or 52950 (see NOTE 7). 
 
Gondolas Model TW, Drawing 51076 (with Dual burners only); Model CW-S (wicker), Drawing 51620 
(with Dual burners only); Model RB6, Drawing 52428; Model RB8, Drawing 52430; or Model 
RB5, Drawing 52805; or Model RB12, Drawing 52430-02. 
Fuel Commercial LPG 
 
Maximum Weight For Model CW-S gondola, Drawing 51620, the gross weight limited to 2,000 lbs. or to the weight 
requiring maximum continuous envelope temperature of 250oF., whichever is less. See Balloon 
Flight Manual. 
 
For Model RB5 gondola, Drawing 52805, the gross weight limited to 2,370 lbs. or to the weight 
requiring maximum continuous envelope temperature of 250oF., whichever is less. See Balloon 
Flight Manual. 
For Model TW gondola, Drawing 51076, or Model RB6 gondola, Drawing 52428, Model RB8 
gondola, Drawing 52430, and Model RB12 gondola, Drawing 52430-02, the gross weight limited 
to 2,650 lbs. or to the weight requiring maximum continuous envelope temperature of 250oF., 
whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot.

13 of 37 A15CE 
 
Fuel Capacity For Model TW gondola, Drawing 51076, fuel capacity is limited to six V-10 tanks; or four V-15 
tanks (see NOTE 6). 
 
For Model CW-S gondola, Drawing 51620, fuel capacity is limited to two H-20 tanks; or one H-20 
tank and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 
tanks (see NOTE 6). 
 
For Model RB6 gondola, Drawing 52428, fuel capacity is limited to two V-23 tanks; or two V-23 
tanks and one or two V-15 or V-18 tanks; or three or four V-15 or V-18 tanks. When used with a 
triple burner, a minimum of three tanks is required (see NOTE 6). 
For Model RB8 gondola, Drawing 52430, and Model RB12 gondola, Drawing 52430-02, fuel 
capacity is limited to three V-23 tanks; or two V-23 tanks and one or two or three V-15 or V-18 
tanks; or three or four or five V-15 or V-18 tanks (see NOTE 6). 
 
For Model RB5 gondola, Drawing 52805, fuel capacity is limited to three V-15 tanks; or two V-18 
tanks and one V-15 tank (see NOTE 6). 
Serial Nos. 
Eligible S71A-3001 and up (see NOTE 2). 
XVII - Model S-49A, Hot Air Balloon, Approved September 6, 1990 
Envelope Aerostar Drawing 52049 
Air Heaters Aerostar P/N 52370 (see NOTE 7). 
Gondolas Model RWS (wicker), Drawing 52131; Model ELS (wicker), Drawing 52440; 
Model ELSS (wicker), Drawing 53095; Model RWSW (wicker), Drawing 53030; or Model 
RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1100 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S49A-3001 and up. (See NOTE 2.) 
XVIII - Model QUBE-80, Hot Air Balloon, Approved June 10, 1991 
Envelope Aerostar Drawing 52496 
Air Heaters Aerostar P/N 13050, 14160, 17395, or 52350 (see NOTE 7). 
Gondola Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model RWS 
(wicker), Drawing 52131; Model RWSW (wicker), Drawing 53030; Model CW-AFX (wicker), 
Drawing 53160; Model RWSW-AFX (wicker), Drawing 53130; Model ELS (wicker), Drawing 
52440; or Model ELSS (wicker), Drawing 53095.

A 15 CE  14 of 37 
 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1450 lbs. or to weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-AFX (wicker), Drawing 53160, fuel 
capacity is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 
tanks; or two or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible Q-3001 and up (see NOTE 2). 
XIX - Model S-57S, Hot Air Balloon, Approved January 27, 1992 
Envelope Aerostar Drawing B-52579 
Air Heaters Aerostar P/N 10118, R-12323, 13050, 13155, 13180, 14160, 14170, 15370, 15384, 17395, 17398, 
17399, 17400, 17642, 51464, 52350, or 52370 (see NOTE 7). 
Gondolas G Series (aluminum), Drawing 01919; Model W (wicker), Drawing 12717; 
G Series H.P. (aluminum), Drawing 12570; Model W, H.P. (wicker), Drawing 12560; G Series 
H.P. high control (aluminum), Drawing 13843; Model W, H.P. high control (wicker), Drawing 
13842; Model CW (wicker), Drawing 13860; Model RW (wicker), Drawing 14530; Model CW-V 
(wicker), Drawing 15325; Model CW-S (wicker), Drawing 51620; Model RWS (wicker), Drawing 
52131; Model ELS (wicker), Drawing 52440; Model ELSS (wicker), Drawing 53095; 
Model RWSW (wicker), Drawing 53030; Model CW-AFX (wicker), Drawing 53160; or Model 
RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight  For Model CW gondola, Drawing 13860, Model CW-V gondola, Drawing 15325, Model CW-S 
gondola, Drawing 51620, Model RWS, Drawing 52131, and Model CW-AFX (wicker), Drawing 
53160, when used with either H.P. Dual Burner, Drawing 14160, H.P. II Dual Burner, Drawing 
17395, or H.P. III Dual Burner, Drawing 52350, the gross weight limited to 1650 lbs. or to the 
weight requiring maximum continuous envelope temperature of 250oF., whichever is less. See 
Balloon Flight Manual. 
 
For Model ELS gondola, Drawing 52440, and Model ELSS gondola, Drawing 53095, the gross 
weight limited to 1200 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1455 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. see Balloon Flight Manual.

15 of 37 A15CE 
 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, Model CW-S gondola, Drawing 51620, and Model 
CW-AFX (wicker), Drawing 53160, fuel capacity is limited to two H-20 tanks; or one H-20 tank 
and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 tanks 
(see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two H-20 tanks; or two or three or four 
V-10 tanks; or two or three or four V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S57S-3001 and up. (See NOTE 2.) 
XX - Model S-60S, Hot Air Balloon, Approved July 6, 1992 
Envelope Aerostar Drawing B-52589 
Air Heaters Aerostar P/N 10118, 13050, 13155, 13180, 14160, 14170, 15370, 15384, 17395, 17398, 17399, 
17400, 17642, 51464, 52350, or 52370 (see NOTE 7). 
Gondolas G Series (aluminum), Drawing 01919; Model W (wicker), Drawing 12717; 
G Series H.P. (aluminum), Drawing 12570; Model W, H.P. (wicker), Drawing 12560; G Series 
H.P. high control (aluminum), Drawing 13843; Model W, H.P. high control (wicker), Drawing 
13842; Model CW (wicker), Drawing 13860; Model RW (wicker), Drawing 14530; Model CW-V 
(wicker), Drawing 15325; Model CW-S (wicker), Drawing 51620; Model RWS (wicker), Drawing 
52131; Model RWSW (wicker), Drawing 53030; Model CW-AFX (wicker), Drawing 53160; or 
Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight  For Model CW gondola, Drawing 13860; Model CW-V gondola, Drawing 15325; Model CW-S 
gondola, Drawing 51620; Model RWS gondola, Drawing 52131; Model RWSW gondola, Drawing 
53030; Model CW-AFX (wicker), Drawing 53160; and Model RWSW-AFX (wicker), Drawing 
53130, when used with either H.P. Dual Burner, Drawing 14160, H.P. II Dual Burner, Drawing 
17395, or H.P. III Dual Burner, Drawing 52350, the gross weight limited to 1800 lbs. or to the 
weight requiring maximum continuous envelope temperature of 250oF., whichever is less. See 
Balloon Flight Manual. 
 
For all other approved burner and gondola combinations, the gross weight limited to 1470 lbs. or to 
the weight requiring maximum continuous envelope temperature of 250oF., whichever is less. see 
Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot.

A 15 CE  16 of 37 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, Model CW-S gondola, Drawing 51620, and Model 
CW-AFX (wicker), Drawing 53160, fuel capacity is limited to two H-20 tanks; or one H-20 tank 
and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 tanks 
(see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two H-20 tanks; or two or three or four 
V-10 tanks; or two or three or four V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S60S-3001 and up (see NOTE 2). 
XXI - Model 110P, Hot Air Balloon, Approved April 30, 1993 
Envelope Aerostar Drawing 52751 
Air Heaters Aerostar P/N 13050, 14160, 17395, or 52350 (see NOTE 7). 
 
Gondolas  Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model CW-S 
(wicker), Drawing 51620; or Model RWS (wicker), Drawing 52131. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1650 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible 110P-3001 and up (see NOTE 2). 
XXII - Model SPII, Hot Air Balloon, Approved May 14, 1993 
Envelope Aerostar Drawing 52752 
Air Heaters Aerostar P/N 13050, 14160, 17395, or 52350 (see NOTE 7). 
 
Gondolas Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model CW-S 
(wicker), Drawing 51620; Model RWS (wicker), Drawing 52131; or Model RWSW (wicker), 
Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1600 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF.

17 of 37 A15CE 
 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible SPII-3001 and up (see NOTE 2). 
XXIII - Model RXS-8, Hot Air Balloon, Approved May 14, 1993 
Envelope Aerostar Drawing 52788 
Air Heaters Aerostar P/N 13180, 14170, 17395, 17398, 17399, 51464, 52350, or 52370 (see NOTE 7). 
Gondola Model R (polyethylene), Drawing 12580; Model RW (wicker), Drawing 14530; Model 
RWS (wicker), Drawing 52131; Model CW (wicker), Drawing 13860; Model CW-V (wicker), 
Drawing 15325; Model CW-S (wicker), Drawing 51620; Model RWSW (wicker), Drawing 53030; 
Model CW-AFX (wicker), Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight For Model CW gondola, Drawing 13860; Model CW-V gondola, Drawing 15325; Model CW-S 
gondola, Drawing 51620; and Model CW-AFX (wicker), Drawing 53160; when used with either 
H.P. Dual Burner, Drawing 14160, H.P. II Dual Burner, Drawing 17395, or H.P. III Dual Burner, 
Drawing 52350, the gross weight limited to 2000 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. See Balloon Flight Manual. 
For Model RWS gondola, Drawing 52131; Model RWSW gondola, Drawing 53030; and Model 
RWSW-AFX (wicker), Drawing 53130, when used with either H.P. Dual Burner, Drawing 14160, 
H.P. II Dual Burner, Drawing 17395, or H.P. III Dual Burner, Drawing 52350, the gross weight 
limited to 1800 lbs. or to the weight requiring maximum continuous envelope temperature of 
250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1480 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, Model CW-S gondola, Drawing 51620, and Model 
CW-AFX (wicker), Drawing 53160, fuel capacity is limited to two H-20 tanks; or one H-20 tank 
and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 tanks 
(see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 tanks; or two 
or three or four V-15 tanks; or two H-20 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible RXS8-3001 and up (see NOTE 2).

A 15 CE  18 of 37 
 
XXIV - Model RX-9, Hot Air Balloon, Approved September 10, 1993 
Envelope Aerostar Drawing 52799 
Air Heaters Aerostar P/N 14160, 17395, 52350, or 52950 (see NOTE 7). 
 
Gondola Model CW (wicker), Drawing 13860; Model CW-S (wicker), Drawing 51620; Model RB6, 
Drawing 52428; or Model RB5, Drawing 52805. 
Fuel Commercial LPG 
 
Maximum Weight For Model CW gondola, Drawing 13860 and Model CW-S gondola, Drawing 51620, the gross 
weight limited to 2,000 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For Model RB6 gondola, Drawing 52428, or Model RB5 gondola, Drawing 52805, the gross 
weight limited to 2,225 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RB6 gondola, Drawing 52428, fuel capacity is limited to two V-23 tanks; or two V-23 
tanks and one or two V-15 or V-18 tanks; or three or four V -15 or V-18 tanks. When used with a 
triple burner, a minimum of three tanks is required (see NOTE 6). 
For Model RB5 gondola, Drawing 52805, fuel capacity is limited to three V-15 tanks; or two V-18 
tanks and one V-15 tank (see NOTE 6). 
For Model CW gondola, Drawing 13860 and Model CW-S gondola, Drawing 51620,fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTE 6 and 7). 
Serial Nos. 
Eligible RX9-3001 and up (see NOTE 2). 
XXV - Model SPI, Hot Air Balloon, Approved September 10, 1993 
Envelope Aerostar Drawing 52800 
Air Heaters Aerostar P/N 13050, 14160, 17395, or 52350 (see NOTE 7). 
 
Gondolas  Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model CW-S 
(wicker), Drawing 51620; Model RWS (wicker), Drawing 52131; or Model RWSW (wicker), 
Drawing 53030; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1560 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot.

19 of 37 A15CE 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible SPI-3001 and up (see NOTE 2). 
XXVI - Model S-53A, Hot Air Balloon, Approved March 25, 1994 
Envelope Aerostar Drawing 52801 
Air Heaters Aerostar P/N 14160, 14170, 17395, 17398, 52350, or 52370 (see NOTE 7). 
Gondolas  Model CW (wicker), Drawing 13860; Model RWS (wicker), Drawing 52131; Model ELS (wicker), 
Drawing 52440; Model ELSS (wicker), Drawing 53095; Model RWSW (wicker), Drawing 53030; 
Model CW-AFX (wicker), Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
Maximum Weight For Model ELS gondola, Drawing 52440, and Model ELSS gondola, Drawing 53095, the gross 
weight limited to 1100 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1275 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-AFX (wicker), Drawing 53160, fuel 
capacity is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 
tanks; or two or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S53A-3001 and up (see NOTE 2). 
XXVII - Model S-81A, Hot Air Balloon, Approved May 12, 1994 
Envelope Aerostar Drawing 52917 
Air Heaters Aerostar P/N 17395, 52350, or 52950 (see NOTE 7). 
Gondolas Model RB6, Drawing 52428; Model RB8, Drawing 52430; or Model RB12, Drawing 52430-02. 
Fuel Commercial LPG

A 15 CE  20 of 37 
 
 
Maximum Weight  For Model RB12 gondola, Drawing 52430-02; when used with HP III Triple Burner, 
Drawing 52950, the gross weight limited to 3800 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. See Balloon Flight Manual. 
For Model RB8 gondola, Drawing 52430, and Model RB12 gondola, Drawing 52430-02, the gross 
weight limited to 3470 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For Model RB6 gondola, Drawing 52428, the gross weight limited to 2870 lbs. or to the weight 
requiring maximum continuous envelope temperature of 250oF., whichever is less. See Balloon 
Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model RB6 gondola, Drawing 52428, fuel capacity is limited to two V-23 tanks; or two V-23 
tanks and one or two V-15 or V-18 tanks; or three or four V -15 or V-18 tanks. When used with a 
triple burner, a minimum of three tanks is required (see NOTE 6). 
For Model RB8 gondola, Drawing 52430, and Model RB12 gondola, Drawing 52430-02, fuel 
capacity is limited to three V-23 tanks; or two V-23 tanks and one or two or three V-15 or V-18 
tanks; or three or four or five V-15 or V-18 tanks (see NOTE 6). 
Serial Nos. 
Eligible S81A-3001 and up (see NOTE 2). 
XXVIII - Model ARKY, Hot Air Balloon, Approved May 19, 1994 
Envelope Aerostar Drawing 52907 
Air Heaters Aerostar P/N 13050, 14160, 17395, or 52350 (see NOTE 7). 
 
Gondolas Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model CW-S 
(wicker), Drawing 51620; Model RWS (wicker), Drawing 52131; or Model RWSW (wicker), 
Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1670 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible ARKY-3001 and up (see NOTE 2).

21 of 37 A15CE 
 
XXIX - Model SPIII, Hot Air Balloon, Approved May 19, 1994 
Envelope Aerostar Drawing 53000 
Air Heaters Aerostar P/N 13050, 14160, 17395, or 52350 (see NOTE 7). 
 
Gondolas Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model CW-S 
(wicker), Drawing 51620; Model RWS (wicker), Drawing 52131; or Model RWSW (wicker), 
Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1500 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible SPIII-3001 and up (see NOTE 2). 
XXX - Model BUNY, Hot Air Balloon, Approved September 13, 1994 
Envelope Aerostar Drawing 53001 
Air Heaters Aerostar P/N 13050, 14160, 17395, or 52350 (see NOTE 7). 
 
Gondolas Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model CW-S 
(wicker), Drawing 51620; Model RWS (wicker), Drawing 52131; or Model RWSW (wicker), 
Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 2100 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible BUNY-3001 and up (see NOTE 2).

A 15 CE  22 of 37 
 
XXXI - Model COOK, Hot Air Balloon, Approved September 13, 1994 
Envelope Aerostar Drawing 53003 
Air Heaters Aerostar P/N 13050, 14160, 17395, or 52350 (see NOTE 7). 
 
Gondolas  Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model CW-S 
(wicker), Drawing 51620; Model RWS (wicker), Drawing 52131; or Model RWSW (wicker), 
Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1650 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible COOK-3001 and up (see NOTE 2). 
XXXII - Model BAG, Hot Air Balloon, Approved December 20, 1994 
Envelope Aerostar Drawing 53004 
Air Heaters Aerostar P/N 13050, 14160, 17395, or 52350 (see NOTE 7). 
 
Gondolas Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model CW-S 
(wicker), Drawing 51620; Model RWS (wicker), Drawing 52131; or Model RWSW (wicker), 
Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1700 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible BAG-3001 and up (see NOTE 2).

23 of 37 A15CE 
 
XXXIII - Model BRUT, Hot Air Balloon, Approved June 20, 1995 
Envelope Aerostar Drawing 53033 
Air Heaters Aerostar P/N 13050, 14160, 17395, or 52350 (see NOTE 7). 
 
Gondolas  Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model RWS 
(wicker), Drawing 52131; or Model RWSW (wicker), Drawing 53030. 
Fuel Commercial LPG 
Maximum Weight Gross weight limited to 1550 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, fuel capacity is limited to two H-20 tanks; or one H-20 
tank and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 
tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible BRUT-3001 and up (see NOTE 2). 
XXXIV - Model PCORN, Hot Air Balloon, Approved June 20, 1995 
Envelope Aerostar Drawing 53069 
Air Heaters Aerostar P/N 13050, 14160, 17395, 52350, or 52370 (see NOTE 7). 
 
Gondolas  Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model RWS 
(wicker), Drawing 52131; Model ELS (wicker), Drawing 52440; Model ELSS (wicker), Drawing 
53095; or Model RWSW (wicker), Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1700 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot.

A 15 CE  24 of 37 
 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, fuel capacity is limited to two H-20 tanks; or one H-20 
tank and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 
tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-10 or V-15 tanks 
(see NOTES 6 and 7). 
Serial Nos. 
Eligible PCORN-3001 and up (see NOTE 2). 
XXXV - Model S-51A, Hot Air Balloon, Approved May 22, 1996 
Envelope Aerostar Drawing 53151 
Air Heaters Aerostar P/N 14160, 14170, 17395, 17398, 52350, or 52370 (see NOTE 7). 
Gondolas Model CW (wicker), Drawing 13860; Model RWS (wicker), Drawing 52131; Model ELS (wicker), 
Drawing 52440; Model RWSW (wicker), Drawing 53030; Model ELSS (wicker), Drawing 53095; 
Model CW-AFX (wicker), Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
Maximum Weight For Model ELS gondola, Drawing 52440, and Model ELSS gondola, Drawing 53095, the gross 
weight limited to 1100 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1275 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-AFX (wicker), Drawing 53160, fuel 
capacity is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 
tanks; or two or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131, fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S51A-3001 and up (see NOTE 2).

25 of 37 A15CE 
 
XXXVI - Model CAKE, Hot Air Balloon, Approved July 3, 1996 
Envelope Aerostar Drawing 53171 
Air Heaters Aerostar P/N 17395 or 52350 (see NOTE 7). 
 
Gondolas Model CW (wicker), Drawing 13860; Model CW-S (wicker), Drawing 51620; Model RWS 
(wicker), Drawing 52131; or Model RWSW (wicker), Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 2100 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131, fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible CAKE-3001 and up (see NOTE 2). 
XXXVII - Model SUN, Hot Air Balloon, Approved July 18, 1996 
Envelope Aerostar Drawing 53169 
Air Heaters Aerostar P/N 17395 or 52350 (see NOTE 7). 
 
Gondolas  Model CW (wicker), Drawing 13860; Model RWSW (wicker), Drawing 53030; Model CW-AFX 
(wicker), Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1650 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-AFX (wicker), Drawing 53160, fuel 
capacity is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 
tanks; or two or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible SUN-3001 and up (see NOTE 2).

A 15 CE  26 of 37 
 
XXXVIII - Model DAISY, Hot Air Balloon, Approved May 12, 1998 
Envelope Aerostar Drawing 53174 
Air Heaters Aerostar P/N 17395 or 52350 (see NOTE 7). 
 
Gondolas Model CW (wicker), Drawing 13860; Model RWSW (wicker), Drawing 53030; Model CW-AFX 
(wicker), Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 2250 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-AFX (wicker), Drawing 53160, fuel 
capacity is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 
tanks; or two or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible DAISY-3001 and up (see NOTE 2). 
XXXIX - Model BEAR, Hot Air Balloon, Approved April 30, 1999 
Envelope Aerostar Drawing 53180 
Air Heaters Aerostar P/N 17395 or 52350 (see NOTE 7). 
 
Gondolas Model CW (wicker), Drawing 13860; Model RWSW (wicker), Drawing 53030; Model CW-AFX 
(wicker), Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1900 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-AFX (wicker), Drawing 53160, fuel 
capacity is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 
tanks; or two or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible BEAR-3001 and up (see NOTE 2).

27 of 37 A15CE 
 
XL - Model S-64A, Hot Air Balloon, Approved January 31, 2000 
Envelope Aerostar Drawing 53098 
Air Heaters Aerostar P/N 14160, 17395, 52350, or 52950 (see NOTE 7). 
Gondola Model CW (wicker), Drawing 13860; Model CW-S (wicker), Drawing 51620; Model RB6, 
Drawing 52428; or Model RB5, Drawing 52805. 
Fuel Commercial LPG 
Maximum Weight For Model CW gondola, Drawing 13860 and Model CW-S gondola, Drawing 51620, the gross 
weight limited to 2,000 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For Model RB6 gondola, Drawing 52428, or Model RB5 gondola, Drawing 52805, the gross 
weight limited to 2,225 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RB6 gondola, Drawing 52428, fuel capacity is limited to two V-23 tanks; or two V-23 
tanks and one or two V-15 or V-18 tanks; or three or four V -15 or V-18 tanks. When used with a 
triple burner, a minimum of three tanks is required (see NOTE 6). 
For Model RB5 gondola, Drawing 52805, fuel capacity is limited to three V-15 tanks; or two V-18 
tanks and one V-15 tank (see NOTE 6). 
For Model CW gondola, Drawing 13860 and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTE 6 and 7). 
Serial Nos. 
Eligible S64A-3001 and up (see NOTE 2). 
XLI - Model CELL, Hot Air Balloon, Approved July 18, 2000 
Envelope Aerostar Drawing 53205 
Air Heaters Aerostar P/N 17395 or 52350 (see NOTE 7). 
 
Gondolas  Model CW (wicker), Drawing 13860; Model CW-S (wicker), Drawing 51620; Model RWS 
(wicker), Drawing 52131;or Model RWSW (wicker), Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1500 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot.

A 15 CE  28 of 37 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131, fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible CELL-3001 and up (see NOTE 2). 
XLII - Model GEOSPHERE, Hot Air Balloon, Approved August 9, 2000 
Envelope Aerostar Drawing 53207 
Air Heaters Aerostar P/N 17395 or 52350 (see NOTE 7). 
 
Gondolas  Model CW (wicker), Drawing 13860; Model CW-S (wicker), Drawing 51620; Model RWS 
(wicker), Drawing 52131;or Model RWSW (wicker), Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 2,000 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131, fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible GEOSPHERE-3001 and up (see NOTE 2). 
XLIII - Model BRAIN, Hot Air Balloon, Approved August 8, 2001 
Envelope Aerostar Drawing 53217 
Air Heaters Aerostar P/N 17395 or 52350 (see NOTE 7). 
 
Gondolas Model CW (wicker), Drawing 13860; Model CW-S (wicker), Drawing 51620; Model RWS 
(wicker), Drawing 52131;or Model RWSW (wicker), Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 2,500 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot.

29 of 37 A15CE 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131, fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible BRAIN-3001 and up (see NOTE 2). 
XLIV - Model HOUSE, Hot Air Balloon, Approved May 8, 2002 
Envelope Aerostar Drawing 53227 
Air Heaters Aerostar P/N 17395 or 52350 (see NOTE 7). 
 
Gondolas  Model CW (wicker), Drawing 13860; Model CW-S (wicker), Drawing 51620; Model RWS 
(wicker), Drawing 52131;or Model RWSW (wicker), Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 2,000 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. See Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 tanks; or two 
or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131, fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible HOUSE-3001 and up (see NOTE 2). 
XLV - Model S-53H, Hot Air Balloon, Approved June 5, 2002 
Envelope Aerostar Drawing 53228 
Air Heaters Aerostar P/N 14160, 14170, 17395, 17398, 52350, or 52370 (see NOTE 7). 
Gondolas  Model CW (wicker), Drawing 13860; Model RWS (wicker), Drawing 52131; Model ELS (wicker), 
Drawing 52440; Model ELSS (wicker), Drawing 53095; Model RWSW (wicker), Drawing 53030; 
Model CW-AFX (wicker), Drawing 53160; or Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
Maximum Weight For Model ELS gondola, Drawing 52440, and Model ELSS gondola, Drawing 53095, the gross 
weight limited to 1100 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1275 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF.

A 15 CE  30 of 37 
 
 
Minimum Crew One (1) Pilot. 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-AFX (wicker), Drawing 53160, fuel 
capacity is limited to two H-20 tanks; or one H-20 tank and one or two V-10 or V-15 or V-18 
tanks; or two or three or four V-10 or V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S53H-3001 and up (see NOTE 2). 
XLVI - Model S-60H, Hot Air Balloon, Approved February 11, 2003 
Envelope Aerostar Drawing 53244 
Air Heaters Aerostar P/N 10118, 13050, 13155, 13180, 14160, 14170, 15370, 15384, 17395, 17398, 17399, 
17400, 17642, 51464, 52350, or 52370 (see NOTE 7). 
Gondolas G Series (aluminum), Drawing 01919; Model W (wicker), Drawing 12717; 
G Series H.P. (aluminum), Drawing 12570; Model W, H.P. (wicker), Drawing 12560; G Series 
H.P. high control (aluminum), Drawing 13843; Model W, H.P. high control (wicker), Drawing 
13842; Model CW (wicker), Drawing 13860; Model RW (wicker), Drawing 14530; Model CW-V 
(wicker), Drawing 15325; Model CW-S (wicker), Drawing 51620; Model RWS (wicker), Drawing 
52131; Model RWSW (wicker), Drawing 53030; Model CW-AFX (wicker), Drawing 53160; or 
Model RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight  For Model CW gondola, Drawing 13860; Model CW-V gondola, Drawing 15325; Model CW-S 
gondola, Drawing 51620; Model RWS gondola, Drawing 52131; Model RWSW gondola, Drawing 
53030; Model CW-AFX (wicker), Drawing 53160; and Model RWSW-AFX (wicker), Drawing 
53130, when used with either H.P. Dual Burner, Drawing 14160, H.P. II Dual Burner, Drawing 
17395, or H.P. III Dual Burner, Drawing 52350, the gross weight limited to 1800 lbs. or to the 
weight requiring maximum continuous envelope temperature of 250oF., whichever is less. See 
Balloon Flight Manual. 
 
For all other approved burner and gondola combinations, the gross weight limited to 1470 lbs. or to 
the weight requiring maximum continuous envelope temperature of 250oF., whichever is less. see 
Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot.

31 of 37 A15CE 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, Model CW-S gondola, Drawing 51620, and Model 
CW-AFX (wicker), Drawing 53160, fuel capacity is limited to two H-20 tanks; or one H-20 tank 
and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 tanks 
(see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two H-20 tanks; or two or three or four 
V-10 tanks; or two or three or four V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S60H-3001 and up (see NOTE 2). 
XLVII - Model S-57H, Hot Air Balloon, Approved April 7, 2003 
Envelope Aerostar Drawing B-53249 
Air Heaters Aerostar P/N 10118, R-12323, 13050, 13155, 13180, 14160, 14170, 15370, 15384, 17395, 17398, 
17399, 17400, 17642, 51464, 52350, or 52370 (see NOTE 7). 
Gondolas G Series (aluminum), Drawing 01919; Model W (wicker), Drawing 12717; 
G Series H.P. (aluminum), Drawing 12570; Model W, H.P. (wicker), Drawing 12560; G Series 
H.P. high control (aluminum), Drawing 13843; Model W, H.P. high control (wicker), Drawing 
13842; Model CW (wicker), Drawing 13860; Model RW (wicker), Drawing 14530; Model CW-V 
(wicker), Drawing 15325; Model CW-S (wicker), Drawing 15620; Model RWS (wicker), Drawing 
52131; Model ELS (wicker), Drawing 52440; Model ELSS (wicker), Drawing 53095; 
Model RWSW (wicker), Drawing 53030; Model CW-AFX (wicker), Drawing 53160; or Model 
RWSW-AFX (wicker), Drawing 53130. 
Fuel Commercial LPG 
 
Maximum Weight  For Model CW gondola, Drawing 13860, Model CW-V gondola, Drawing 15325, Model CW-S 
gondola, Drawing 51620, Model RWS, Drawing 52131, and Model CW-AFX (wicker), Drawing 
53160, when used with either H.P. Dual Burner, Drawing 14160, H.P. II Dual Burner, Drawing 
17395, or H.P. III Dual Burner, Drawing 52350, the gross weight limited to 1650 lbs. or to the 
weight requiring maximum continuous envelope temperature of 250oF., whichever is less. See 
Balloon Flight Manual. 
For Model ELS gondola, Drawing 52440, and Model ELSS gondola, Drawing 53095, the gross 
weight limited to 1200 lbs. or to the weight requiring maximum continuous envelope temperature 
of 250oF., whichever is less. See Balloon Flight Manual. 
For all other gondolas, the gross weight limited to 1455 lbs. or to the weight requiring maximum 
continuous envelope temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot.

A 15 CE  32 of 37 
 
Fuel Capacity For Model ELS gondola, Drawing 52440, fuel capacity is limited to one H-20 tank with dual liquid 
feed; or one V-15 tank and one H-20 tank, one of which must have a dual liquid feed; or two V-15 
tanks, one of which must have a dual liquid feed (see NOTE 6). 
 
For Model ELSS gondola, Drawing 53095, fuel capacity is limited to one H-25 tank with dual 
liquid feed; or one H-25 tank with dual liquid feed and one V-15 tank; or two V-15 tanks, one of 
which must have a dual liquid feed (see NOTE 6). 
 
For Model RWSW gondola, Drawing 53030, and Model RWSW-AFX (wicker), Drawing 53130, 
fuel capacity is limited to one H-20 tank and one or two V-15 or V-18 tanks; or two or three or four 
V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, Model CW-S gondola, Drawing 51620, and Model 
CW-AFX (wicker), Drawing 53160, fuel capacity is limited to two H-20 tanks; or one H-20 tank 
and one or two V-10 or V-15 or V-18 tanks; or two or three or four V-10 or V-15 or V-18 tanks 
(see NOTES 6 and 7). 
 
For Model RWS gondola, Drawing 52131 fuel capacity is limited to two or three or four V-10 or 
V-15 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two H-20 tanks; or two or three or four 
V-10 tanks; or two or three or four V-15 tanks (see NOTES 6 and 7). 
Serial Nos. 
Eligible S57H-3001 and up. (See NOTE 2.) 
XLVIII - Model 110C, Hot Air Balloon, Approved May 31, 2005 
Envelope Aerostar Drawing 53262 
Air Heaters Aerostar P/N 17395 or 52350 (see NOTE 7). 
 
Gondolas Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; Model CW-S 
(wicker), Drawing 51620; or Model RWS (wicker), Drawing 52131;or Model RWSW (wicker), 
Drawing 53030. 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1550 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-15 or V-18 tanks; or two or three 
or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four V-15 tanks (see 
NOTES 6 and 7). 
Serial Nos. 
Eligible 110C-3001 and up (see NOTE 2). 
XLIX - Model PNUT, Hot Air Balloon, Approved July 31, 2006 
Envelope Aerostar Drawing 53278 
Air Heaters Aerostar P/N 17395 or 52350 (see NOTE 7). 
 
Gondolas Model CW (wicker), Drawing 13860; Model CW-V (wicker), Drawing 15325; or Model RWS 
(wicker), Drawing 52131;or Model RWSW (wicker), Drawing 53030.

33 of 37 A15CE 
 
 
Fuel Commercial LPG 
 
Maximum Weight Gross weight limited to 1650 lbs. or to the weight requiring maximum continuous envelope 
temperature of 250oF., whichever is less. see Balloon Flight Manual. 
Allowable Envelope o Temperature 1. Never exceed: 275 F. o o 2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 250 F. to 275 F. 
3. Maximum continuous: 250oF. 
Minimum Crew One (1) Pilot. 
 
Fuel Capacity For Model RWSW gondola, Drawing 53030, fuel capacity is limited to one H-20 tank and one or 
two V-15 or V-18 tanks; or two or three or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For Model CW gondola, Drawing 13860, and Model CW-S gondola, Drawing 51620, fuel capacity 
is limited to two H-20 tanks; or one H-20 tank and one or two V-15 or V-18 tanks; or two or three 
or four V-15 or V-18 tanks (see NOTES 6 and 7). 
 
For all other approved gondolas, fuel capacity is limited to two or three or four or V-15 tanks (see 
NOTES 6 and 7). 
Serial Nos. 
Eligible PNUT-3001 and up (see NOTE 2). 
Data Pertinent to All Models 
Certification 
Basis Part 31 of the Federal Aviation Regulations dated July 1, 1964, as amended by 31-1 and 31-2. 
Application for Type Certificate dated December 12, 1967. Type Certificate No. A15CE issued 
December 10, 1968. 
Models 78C, 90C, 110C, 110P, ARKY, BAG, BEAR, BRAIN, BRUT, BUNY, CAKE, CELL, 
COOK, CTS, DAISY, GEOSPHERE, HOUSE, PCORN, PNUT, QUBE-80, SPI, SPII, SPIII, and 
SUN: 
Part 31 of the Federal Aviation Regulations dated July 1, 1964, as amended by 31-1 and 31-2. In 
addition, FAR 31.17 and 31.19 of amendment 31-4. 
Production 
Basis Production Certificate No. 3GL. 
Equipment The basic required equipment as prescribed in the applicable airworthiness regulations (see 
Certification Basis) must be installed in the aircraft for certification, except for safety belts. 
In addition to the above required equipment, the following equipment is also required: 
Burner lighter-sparker, matches or equal. 
Protective headgear for pilot and passengers. 
Approved instrumentation package (see NOTE 8). 
FAA Approved Balloon Flight Manual dated December 9, 1968 (S-50A), reissued April 15, 1983, 
or later approved revision. 
FAA Approved Balloon Flight Manual dated July 10, 1969 (S-40A), or later approved revision. 
FAA Approved Balloon Flight Manual dated April 30, 1971 (S-60A), reissued April 15, 1983, or 
later approved revision. 
FAA Approved Balloon Flight Manual dated April 2, 1973 (S-55A), reissued April 15, 1983, or 
later approved revision. 
FAA Approved Balloon Flight Manual dated September 4, 1974, (RX-6), reissued April 15, 1983, 
or later approved revision. 
FAA Approved Balloon Flight Manual dated November 21, 1978 (RX-7), reissued April 15, 1983, 
or later approved revision. 
FAA Approved Balloon Flight Manual dated September 19, 1979 (S-66A), reissued 
April 15, 1983, or later approved revision. 
FAA Approved Balloon Flight Manual dated March 31, 1980 (W100LB), or later approved 
revision. 
FAA Approved Balloon Flight Manual dated April 15, 1983 (S-77A), or later approved revision. 
FAA Approved Balloon Flight Manual dated June 19, 1987 (S -57A), or later approved revision. 
FAA Approved Balloon Flight Manual dated April 26, 1988 (S-52A), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 1, 1989 (RX-8), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 1, 1989 (78C), or later approved revision.

A 15 CE  34 of 37 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Maintenance and 
FAA Approved Balloon Flight Manual dated July 18, 1989 (90C), or later approved revision. 
FAA Approved Balloon Flight Manual dated October 6, 1989 (CTS), or later approved revision. 
FAA Approved Balloon Flight Manual dated August 23, 1990 (S-71A), or later approved revision. 
FAA Approved Balloon Flight Manual dated September 5, 1990 (S-49A), or later approved 
revision. 
FAA Approved Balloon Flight Manual dated June 10, 1991 (QUBE-80), or later approved revision. 
FAA Approved Balloon Flight Manual dated January 24, 1992 (S-57S), or later approved revision. 
FAA Approved Balloon Flight Manual dated July 2, 1992 (S-60S), or later approved revision. 
FAA Approved Balloon Flight Manual dated April 30, 1993 (110P), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 14, 1993 (SPII), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 14, 1993 (RXS-8), or later approved revision. 
FAA Approved Balloon Flight Manual dated September 10, 1993 (RX-9), or later approved 
revision. 
FAA Approved Balloon Flight Manual dated September 10, 1993 (SPI), or later approved revision. 
FAA Approved Balloon Flight Manual dated March 25, 1994 (S-53A), or later approved revision. 
FAA Approved Balloon Flight Manual dated April 25, 1994 (S-81A), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 19, 1994 (ARKY), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 19, 1994 (SPIII), or later approved revision. 
FAA Approved Balloon Flight Manual dated September 13, 1994 (BUNY), or later approved 
revision. 
FAA Approved Balloon Flight Manual dated September 13, 1994 (COOK), or later approved 
revision. 
FAA Approved Balloon Flight Manual dated December 19, 1994 (BAG), or later approved 
revision. 
FAA Approved Balloon Flight Manual dated June 16, 1995 (BRUT), or later approved revision. 
FAA Approved Balloon Flight Manual dated June 16, 1995 (PCORN), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 22, 1996 (S-51A), or later approved revision. 
FAA Approved Balloon Flight Manual dated July 2, 1996 (CAKE), or later approved revision. 
FAA Approved Balloon Flight Manual dated July 18, 1996 (SUN), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 12, 1998 (DAISY), or later approved revision. 
FAA Approved Balloon Flight Manual dated April 30, 1999 (BEAR), or later approved revision. 
FAA Approved Balloon Flight Manual dated January 31, 2000 (S-64A), or later approved revision. 
FAA Approved Balloon Flight Manual dated July 17, 2000 (CELL), or later approved revision. 
FAA Approved Balloon Flight Manual dated August 9, 2000 (GEOSPHERE), or later approved 
revision. 
FAA Approved Balloon Flight Manual dated August 8, 2001 (BRAIN), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 8, 2002 (HOUSE), or later approved revision. 
FAA Approved Balloon Flight Manual dated June 3, 2002 (S-53H), or later approved revision. 
FAA Approved Balloon Flight Manual dated February 3, 2003 (S-60H), or later approved revision. 
FAA Approved Balloon Flight Manual dated April 7, 2003 (S-57H), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 31, 2005 (110C), or later approved revision. 
FAA Approved Balloon Flight Manual dated July 31, 2006 (PNUT), or later approved revision. 
Inspection A. The following maintenance must be performed at each annual inspection: 
1. Replace "0" ring stem seal of quick valve. 
2. Install "repair kit" (replace diaphragm and seals) in pressure regulator on Aerostar 
single, double, and 4-barrel burner assemblies; Drawings 09645, 04420, 10118, and 
12323. 
 
B. Annual\100-hr. inspections required by FAR 91.409 must include inspection of fabric condition 
as defined by the latest issue of Aerostar Instructions For Continued Airworthiness. 
 
C. Envelope must be inspected for heat damage, including strength tests of fabric, if template "tell- 
tales" show temperature of 275oF has been exceeded. Templates are installed in seams at 
center of top cap all models. 
D. The fabric and the hook and pile closure tapes shall be inspected as outlined in Aerostar 
Instructions For Continued Airworthiness. 
E. Criteria for repairing the envelope fabric must be obtained from Aerostar and must be 
accomplished in accordance with FAR 43 and AC 43.13. 
F. All Inspections, testing, repairs, and replacements must be accomplished in accordance with the 
latest issue of Aerostar Instructions For Continued Airworthiness. 
 
G. S/N S50A-121 thru -124 envelopes must be inspected for the security and condition of the flat 
seams.

35 of 37 A15CE 
 
NOTE 1. Experimental category Model S-50 balloons S/N -121 thru -123 are eligible as standard category Model S-50A 
balloons upon conformity to Aerostar Drawing 06678 with the following exceptions: 
(1) Balloon envelope may conform to Aerostar Drawing 05957C except section F-F of ECO 1476. 
(2) Maneuvering vent may conform to Aerostar Drawing 00782C. 
(3) Handling line attachment may conform to Aerostar Drawing 00806B. 
Model S-66A balloons S/N -102, -103, -105 are eligible as Model S-66A balloons for a gross weight of 2500 lbs. 
or less if modified to Aerostar Drawing 17653 Revision Letter D or later. 
Model S-66A balloon S/N -101 is eligible as model S-66A for a gross weight of 1800 lbs. or less when 
manufactured in accordance with Raven Drawing 17653, no revision, and 17681, no revision, with single load 
tapes. 
 
NOTE 2.  Each hot air balloon envelope must have an individual registration number. An individual envelope is eligible for 
a Standard Airworthiness Certificate when mated with any approved combination of gondola and burner assembly 
for that model balloon. Change to an eligible combination must be documented by making a logbook entry 
endorsed by pilot in command or certified mechanic. 
NOTE 3. For the purpose of maintenance and inspection, operation records (logbooks) must be maintained with each hot air  
balloon envelope. If burner assemblies and/or gondolas are interchanged, separate records must be maintained for  
the burner and the gondola. 
NOTE 4. Gaseous nitrogen pressurization of fuel tanks is approved only in accordance with the following: 
FAA Approved Balloon Flight Manual dated December 9, 1968 (S-50A), Revision L, dated 9/27/88, or later 
approved revision. 
FAA Approved Balloon Flight Manual dated July 10, 1969 (S-40A), Revision C, dated 9/27/88, or later approved 
revision. 
FAA Approved Balloon Flight Manual dated April 30, 1971 (S-60A), Revision N, dated 9/27/88, or later 
approved revision. 
FAA Approved Balloon Flight Manual dated April 2, 1973 (S-55A), Revision L, dated 9/27/88, or later approved 
revision. 
FAA Approved Balloon Flight Manual dated September 4, 1974, (RX-6), Revision K, dated 9/27/88, or later 
approved revision. 
FAA Approved Balloon Flight Manual dated November 21, 1978 (RX-7), Revision F, dated 9/27/88, or later 
approved revision. 
FAA Approved Balloon Flight Manual dated September 19, 1979 (S-66A), Revision G, dated 9/27/88, or later 
approved revision. 
FAA Approved Balloon Flight Manual dated April 15, 1983 (S-77A), Revision F, dated 9/27/88, or later approved 
revision. 
FAA Approved Balloon Flight Manual dated June 19, 1987 (S-57A), Revision A, dated 9/27/88, or later approved 
revision. 
FAA Approved Balloon Flight Manual dated April 26, 1988 (S-52A), Revision A, dated 9/27/88, or later 
approved revision. 
FAA Approved Balloon Flight Manual dated May 1, 1989 (RX-8), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 1, 1989 (78C), or later approved revision. 
FAA Approved Balloon Flight Manual dated July 18, 1989 (90C), or later approved revision. 
FAA Approved Balloon Flight Manual dated October 6, 1989 (CTS), or later approved revision. 
FAA Approved Balloon Flight Manual dated August 23, 1990 (S-71A), or later approved revision. 
FAA Approved Balloon Flight Manual dated September 5, 1990 (S-49A), or later approved revision. 
FAA Approved Balloon Flight Manual dated June 10, 1991 (QUBE-80), or later approved revision. 
FAA Approved Balloon Flight Manual dated January 24, 1992 (S-57S), or later approved revision. 
FAA Approved Balloon Flight Manual dated July 2, 1992 (S-60S), or later approved revision. 
FAA Approved Balloon Flight Manual dated April 30, 1993 (110P), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 14, 1993 (SPII), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 14, 1993 (RXS-8), or later approved revision. 
FAA Approved Balloon Flight Manual dated September 10, 1993 (RX-9), or later approved revision. 
FAA Approved Balloon Flight Manual dated September 10, 1993 (SPI), or later approved revision. 
FAA Approved Balloon Flight Manual dated March 25, 1994 (S-53A), or later approved revision. 
FAA Approved Balloon Flight Manual dated April 25, 1994 (S-81A), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 19, 1994 (ARKY), or later approved revision.  
FAA Approved Balloon Flight Manual dated May 19, 1994 (SPIII), or later approved revision. 
FAA Approved Balloon Flight Manual dated September 13, 1994 (BUNY), or later approved revision. 
FAA Approved Balloon Flight Manual dated September 13, 1994 (COOK), or later approved revision. 
FAA Approved Balloon Flight Manual dated December 19, 1994 (BAG), or later approved revision. 
FAA Approved Balloon Flight Manual dated June 16, 1995 (BRUT), or later approved revision. 
FAA Approved Balloon Flight Manual dated June 16, 1995 (PCORN), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 22, 1996 (S-51A), or later approved revision.

A 15 CE  36 of 37 
 
FAA Approved Balloon Flight Manual dated July 2, 1996 (CAKE), or later approved revision. 
FAA Approved Balloon Flight Manual dated July 18, 1996 (SUN), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 12, 1998 (DAISY), or later approved revision. 
FAA Approved Balloon Flight Manual dated April 30, 1999 (BEAR), or later approved revision. 
FAA Approved Balloon Flight Manual dated January 31, 2000 (S-64A), or later approved revision. 
FAA Approved Balloon Flight Manual dated July 17, 2000 (CELL), or later approved revision. 
FAA Approved Balloon Flight Manual dated August 9, 2000 (GEOSPHERE), or later approved revision. 
FAA Approved Balloon Flight Manual dated August 8, 2001 (BRAIN), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 8, 2002 (HOUSE), or later approved revision. 
FAA Approved Balloon Flight Manual dated June 3, 2002 (S-53H), or later approved revision. 
FAA Approved Balloon Flight Manual dated February 3, 2003 (S-60H), or later approved revision. 
FAA Approved Balloon Flight Manual dated April 7, 2003 (S-57H), or later approved revision. 
FAA Approved Balloon Flight Manual dated May 31, 2005 (110C), or later approved revision. 
FAA Approved Balloon Flight Manual dated July 31, 2006 (PNUT), or later approved revision. 
 
NOTE 5. Pilot heat exchanger is approved for all models in accordance with Aerostar drawing 52285, dated 5/2/88, or later 
FAA approved revision. 
NOTE 6. Eligible fuel tank designations: 
 
Fuel Tank Type Capacity Aerostar P/N 
H-20 Horizontal 20-ga1. (at 85% fill) 07752 
H-25 Horizontal 25-ga1. (at 85% fill) 53052 
V-10 Vertical 10-gal. (at 80% fill) 09738, 15326, 51477 
V-15 Vertical 15-gal. (at 85% fill) 51977 
V-18 Vertical 18-gal. (at 85% fill) 53037 
V-23 Vertical 23-gal. (at 85% fill) 52427 
NOTE 7. Eligible Burner designations: 
 
Burner Aerostar P/N Burner Aerostar P/N 
Double 04420 HP II Dual 17395 
Single 09645 HP II Single 17398 
Double 10118 Rally HP II 17399 
Four-Burner 12323 HP II Convertible 17400 
Dual Lo-C 13050 HP II Burner Blower 17642 
Single Lo-C 13155 Dual Inlet Rally 51464 
Rally HP 13180 HP III Dual 52350 
Dual Hi-C 14160 HP III Single 52370-01 
Single Hi-C 14170 Aurora Single 52370-02 
Convertible 15370 HP III Triple 52950 
Burner Blower 15384   
 
If balloon is equipped with Rally Dual-Inlet burner assembly 51464, HP II single burner assembly 17398 Rev. L 
or later, or H.P. III single burner assembly 52370, one 51477 or one 51977-1 or one 07752-5 or one 53037-2 tank 
is required. The 51477, 51977-1, 07752-5, and 53037-2 tanks may be used only with the Rally Dual-Inlet burner, 
HP II single burner (Rev. L or later), and H.P. III single burner. 
If the balloon is equipped with an HP III Triple Burner Assembly 52950, a minimum of three vertical fuel tanks 
with three independent burner hoses must be used. 
NOTE 8. Eligible Instrument Packages: 
 
Description Aerostar P/N 
Instrument Panel Assembly 10288 
Instrument Case Assembly 12563 
Instrument Case Assembly 12953 
Instrument Panel Assembly 14115 
Instrument Case Assembly 14182 
Instrument Case Assembly 14572 
Instrument Panel 51094 
Retrofit Procedure, Digital Pyro 51193 
Instrument Package, Ball 51677 
Instrument Package Assembly, Ball 52279 
Aegis IR System 53040 
Instrument System, Ball M57 53218 
Instrument System, Digitool 53264 
Balloon Instrument Model DBI-  
002

37 of 37  A15CE
-- END --
```

## ADs (8, in force first)

- [AD 2013-03-10](https://openairdocs.org/ad/2013-03-10): Hardware · Aeronaut Instruction Research Skysailor 105, Skysailor 90, 110C and 439 more. Effective Mar 19, 2013
- [AD 93-16-13](https://openairdocs.org/ad/93-16-13): Fuel Hose · Aerostar International 110P, 78C, 90C and 20 more. Effective Oct 15, 1993
- [AD 90-25-09](https://openairdocs.org/ad/90-25-09): Suspension Cables · Aerostar International RX-6, RX-7, RX-8 and 8 more. Effective Jan 14, 1991
- [AD 86-10-11 R1](https://openairdocs.org/ad/86-10-11-R1): Fuel Supply Hose Assemblies · Aerostar International RX-6, RX-7, S-40A and 6 more. Effective Jul 10, 1986
- [AD 81-21-02 R1](https://openairdocs.org/ad/81-21-02-R1): Hook And Pile Fastener Tape · Aerostar International RX-6, RX-7, S-40A and 5 more. Effective Mar 8, 1984
- [AD 80-01-03](https://openairdocs.org/ad/80-01-03): Parachute Top Release · Aerostar International S-50A, S-55A and S-60A. Effective Jan 7, 1980
- [AD 76-03-04](https://openairdocs.org/ad/76-03-04): Gondola Liner · Aerostar International RX-6. Effective Feb 13, 1976
- [AD 75-19-04](https://openairdocs.org/ad/75-19-04): Valve System · Aerostar International RX-6, S-40A, S-50A and 2 more. Effective Sep 17, 1975

## Registered aircraft by registry model (OpenAirDocs)

- [Aerostar International RX 8](https://openairdocs.org/model/aerostar-international-rx-8): 213 aircraft (registry code 7487008)
- [Aerostar International RX-7](https://openairdocs.org/model/aerostar-international-rx-7): 96 aircraft (registry code 7487007)
- [Aerostar International RAVEN S49A](https://openairdocs.org/model/aerostar-international-raven-s49a): 89 aircraft (registry code 7484049)
- [Aerostar International S-60A](https://openairdocs.org/model/aerostar-international-s-60a): 77 aircraft (registry code 7486060)
- [Aerostar International RXS-8](https://openairdocs.org/model/aerostar-international-rxs-8): 64 aircraft (registry code 7487009)
- [Aerostar International S53A](https://openairdocs.org/model/aerostar-international-s53a): 63 aircraft (registry code 7487906)
- [Raven S55A](https://openairdocs.org/model/raven-s55a): 57 aircraft (registry code 7480402)
- [Aerostar International RAVEN S57-A](https://openairdocs.org/model/aerostar-international-raven-s57-a): 38 aircraft (registry code 7485057)
- [Aerostar International S-57A](https://openairdocs.org/model/aerostar-international-s-57a): 38 aircraft (registry code 7485001)
- [Raven S-60A](https://openairdocs.org/model/raven-s-60a): 32 aircraft (registry code 7480606)
- [Raven Industries RALLY RX7](https://openairdocs.org/model/raven-industries-rally-rx7): 27 aircraft (registry code 7480503)
- [Aerostar International S-49A](https://openairdocs.org/model/aerostar-international-s-49a): 14 aircraft (registry code 7484050)
- [Aerostar International S-55A](https://openairdocs.org/model/aerostar-international-s-55a): 13 aircraft (registry code 7485002)
- [Aerostar International S57H](https://openairdocs.org/model/aerostar-international-s57h): 13 aircraft (registry code 7485009)
- [Aerostar International S-57S](https://openairdocs.org/model/aerostar-international-s-57s): 12 aircraft (registry code 7485058)
- [Raven S-50A](https://openairdocs.org/model/raven-s-50a): 12 aircraft (registry code 7480204)
- [Aerostar International RAVEN S-55A](https://openairdocs.org/model/aerostar-international-raven-s-55a): 10 aircraft (registry code 7485055)
- [Aerostar International RAVEN S52A](https://openairdocs.org/model/aerostar-international-raven-s52a): 10 aircraft (registry code 7485052)
- [Aerostar International S-66A](https://openairdocs.org/model/aerostar-international-s-66a): 10 aircraft (registry code 7486066)
- [Raven Industries RX6](https://openairdocs.org/model/raven-industries-rx6): 10 aircraft (registry code 7480502)
- [Aerostar International S-51A](https://openairdocs.org/model/aerostar-international-s-51a): 8 aircraft (registry code 7485004)
- [Aerostar International S-71A](https://openairdocs.org/model/aerostar-international-s-71a): 8 aircraft (registry code 7487072)
- [Aerostar International S-77A](https://openairdocs.org/model/aerostar-international-s-77a): 7 aircraft (registry code 7487077)
- [Raven Industries S-66A](https://openairdocs.org/model/raven-industries-s-66a): 6 aircraft (registry code 7480612)
- [Raven S-40A](https://openairdocs.org/model/raven-s-40a): 5 aircraft (registry code 7480104)
- [Aerostar International AEROSTAR S53H](https://openairdocs.org/model/aerostar-international-aerostar-s53h): 4 aircraft (registry code 7487911)
- [Aerostar International S-50A](https://openairdocs.org/model/aerostar-international-s-50a): 4 aircraft (registry code 7485050)
- [Aerostar International S81A](https://openairdocs.org/model/aerostar-international-s81a): 4 aircraft (registry code 7487907)
- [Aerostar International RAVEN S-66A](https://openairdocs.org/model/aerostar-international-raven-s-66a): 3 aircraft (registry code 7486067)
- [Aerostar International RX-9](https://openairdocs.org/model/aerostar-international-rx-9): 3 aircraft (registry code 7487010)
- [Aerostar International S-60S](https://openairdocs.org/model/aerostar-international-s-60s): 3 aircraft (registry code 7487926)
- [Aerostar International AEROSTAR S60H](https://openairdocs.org/model/aerostar-international-aerostar-s60h): 2 aircraft (registry code 7489000)
- [Aerostar International CTS](https://openairdocs.org/model/aerostar-international-cts): 2 aircraft (registry code 7487900)
- [Raven Industries S-60A](https://openairdocs.org/model/raven-industries-s-60a): 2 aircraft (registry code 7480611)
- [Aerostar International ARKY](https://openairdocs.org/model/aerostar-international-arky): 1 aircraft (registry code 7487901)
- [Aerostar International BAG](https://openairdocs.org/model/aerostar-international-bag): 1 aircraft (registry code 7487902)
- [Aerostar International BRAIN](https://openairdocs.org/model/aerostar-international-brain): 1 aircraft (registry code 7487931)
- [Aerostar International BRUT](https://openairdocs.org/model/aerostar-international-brut): 1 aircraft (registry code 7487922)
- [Aerostar International BUNY](https://openairdocs.org/model/aerostar-international-buny): 1 aircraft (registry code 7487921)
- [Aerostar International CAKE](https://openairdocs.org/model/aerostar-international-cake): 1 aircraft (registry code 7485056)
- [Aerostar International RAVEN S-60S](https://openairdocs.org/model/aerostar-international-raven-s-60s): 1 aircraft (registry code 7484058)
- [Aerostar International RAVEN S71A](https://openairdocs.org/model/aerostar-international-raven-s71a): 1 aircraft (registry code 7487071)
- [Aerostar International RX-6](https://openairdocs.org/model/aerostar-international-rx-6): 1 aircraft (registry code 7486006)
- [Aerostar International S53H](https://openairdocs.org/model/aerostar-international-s53h): 1 aircraft (registry code 7486062)
- [Aerostar International S60H](https://openairdocs.org/model/aerostar-international-s60h): 1 aircraft (registry codes 7489001, 7486061)
- [Aerostar International SP I](https://openairdocs.org/model/aerostar-international-sp-i): 1 aircraft (registry code 7487806)
- [Aerostar International SUN](https://openairdocs.org/model/aerostar-international-sun): 1 aircraft (registry code 7485059)
- [Raven Industries S-55A](https://openairdocs.org/model/raven-industries-s-55a): 1 aircraft (registry code 7480609)
- [Raven Industries S77A](https://openairdocs.org/model/raven-industries-s77a): 1 aircraft (registry code 7480650)
- [Aerostar International 110C](https://openairdocs.org/model/aerostar-international-110c): 0 aircraft (registry code 7480561)

All 64: https://openairdocs.org/tcds/A15CE/aircraft.md

## STCs approved under this data sheet (58, first 50)

- [STC SB10564SC](https://openairdocs.org/stc/SB10564SC): Installation of Night Position Lights. Highland Balloon Repair, CRS NHMD682X
- [STC SB00744CH](https://openairdocs.org/stc/SB00744CH): Modify existing envelope by addition of 56 chili pepper appendages to exterior of main body.. Balloonacy LLC
- [STC SB00884CH](https://openairdocs.org/stc/SB00884CH): Modify the existing envelope by the addition of the Shamu modifications to the exterior main body of the balloon.. Balloonacy LLC
- [STC SB01030CH](https://openairdocs.org/stc/SB01030CH): Replace Aerostar Basket/BurnerFuel Tanks with a Cameron Balloons Ltd. (Thunder & Colt) Basket/Burner/Fuel Tanks. Balloonacy LLC
- [STC SB146CH](https://openairdocs.org/stc/SB146CH): Replace Aerostar Basket/Burner with a Cameron Basket/Burner. Balloonacy LLC
- [STC SB1611GL](https://openairdocs.org/stc/SB1611GL): Modify existing envelope by adding 'Pack-Van Modifications' and install Aerostar Aurora (ELS) basket (D-52440) with Aerostar H.P. III single burner(D-52370).. Balloonacy LLC
- [STC SB244CH](https://openairdocs.org/stc/SB244CH): Install The Balloon Works gondola, Model 3.9, 4.0, or 4.5, and The Balloon Works burner, Model T3-017 with the Fire 2 auxiliary heater.. Balloonacy LLC
- [STC SB896GL](https://openairdocs.org/stc/SB896GL): Install The Balloon Works gondola, Model 3.9, 4.0, or 4.5, and burner, Model T3-017.. Balloonacy LLC
- [STC SB09657RC](https://openairdocs.org/stc/SB09657RC): Installation of Aircraft Position Lights. Albuquerque Balloon Center, Inc.
- [STC SB04407AT](https://openairdocs.org/stc/SB04407AT): Installation of the DBI-III Omega. Balloonacy, Ltd. LLC
- [STC SB04113CH](https://openairdocs.org/stc/SB04113CH): Replace the Aerostar International Basket/Burner system with the Cameron Balloons Basket, Part Number CB301C-4, S/N 9465; the Cameron Balloons Burner, Part Number CB579-M1, S/N S5148  S5149.  Replace the Aerostar International fuel tanks with the Cameron Balloons Fuel Tanks, Part Number CBUS1050D, S/Ns 230171, 230177, and 230202.. Nathan Dieringer
- [STC SB04089CH](https://openairdocs.org/stc/SB04089CH): Replace the Aerostar International Basket/Burner system with the Lindstrand Balloons Ltd Basket, Part Number BA-007-A-001, S/N BA1175; the Lindstrand Balloons Ltd Burner, Part Number BU-008-A-002, S/N BU1378.  Replace the Aerostar International fuel tanks with the Lindstrand Balloons Ltd Fuel Tanks, Part Number CY-030-A-001, S/Ns 1519, 1520, and 1521. Carroll Teitsworth
- [STC SB04041CH](https://openairdocs.org/stc/SB04041CH): Replace the Aerostar International Basket/Burner system with the Cameron Balloons Basket, Part Number CB301B-3, S/N 8411; the Cameron Balloons Burner, Part Number CB392A, S/Ns 1150-1176.  Replace the Aerostar International fuel tanks with the Cameron Balloons Fuel Tanks, Part Number CB250A, S/Ns 48152J, 48129J, 48258J, and 48440J.. Cameron Balloons US
- [STC SB04042CH](https://openairdocs.org/stc/SB04042CH): Replace the Aerostar International Basket/Burner system with the Cameron Balloons Basket, Part Number CB301A-7, S/N 8986; the Cameron Balloons Burner, Part Number CB391A, S/N 1852.  Replace the Aerostar International fuel tanks with the Cameron Balloons Fuel Tanks, Part Number CB250A, S/Ns 48201J, 51767J, 51552J, and 31236J.. Cameron Balloons US
- [STC SB04009CH](https://openairdocs.org/stc/SB04009CH): Replace the Aerostar International Basket/Burner system with the Lindstrand Balloons USA Basket, Part Number BA-007-A-001, S/N 1075; the Thunder & Colt Burner, Model Colt MK III, S/N 2366.  Replace the Aerostar International fuel tanks with the Thunder & Colt Fuel Tanks, Part Number T&C V30, S/Ns 2557, 2558, 2559, and 1627.. Pat Irwin
- [STC SB04001CH](https://openairdocs.org/stc/SB04001CH): Replace the Aerostar International Basket/Burner system with the Cameron Balloons Basket, Part Number CB301C-3, S/N 9712; the Cameron Balloons Burner, Part Number CBUS10011-2A, S/Ns V0123 and V0128.  Replace the Aerostar International fuel tanks with the Cameron Balloons Fuel Tanks, Part Number CB2901-B, S/Ns 478, 492, and 509. Frankie J. Martinez
- [STC SB03455CH](https://openairdocs.org/stc/SB03455CH): Replace the Aerostar International Basket/Burner system. Hot Air Marketing LLC
- [STC SB03446CH](https://openairdocs.org/stc/SB03446CH): Replace the Aerostar International Basket/Burner system with the Lindstrand Balloons Ltd Basket, Part Number BA-007-A-001, S/N 1157; the Lindstrand Balloons Ltd Burner, Part Number BU-008-A-002, S/N BU1242.  Replace the Aerostar International fuel tanks with the Lindstrand Balloons Ltd Fuel Tanks, Part Number CY-030-A-001, S/Ns 1409 and 1439; and Cameron Balloons Fuel Tank, Part Number CB250, S/N 24734J.. Kenneth Lehr
- [STC SB03361CH](https://openairdocs.org/stc/SB03361CH): Replace the Aerostar basket, burner & fuel tanks; with Lindstrand basket, burner & fuel tanks. Cameron Balloons US
- [STC SB03362CH](https://openairdocs.org/stc/SB03362CH): Replace the Aerostar basket, burner & fuel tanks; with Lindstrand basket, burner & fuel tanks. Cameron Balloons US
- [STC SB03363CH](https://openairdocs.org/stc/SB03363CH): Replace the Aerostar basket, burner & fuel tanks; with Lindstrand basket, burner & fuel tanks. Cameron Balloons US
- [STC SB03366CH](https://openairdocs.org/stc/SB03366CH): Replace the Aerostar basket, burner & fuel tanks; with Cameron basket, burner, fuel tanks and instruments via the standard Cameron carbiners. Cameron Balloons US
- [STC SB03336CH](https://openairdocs.org/stc/SB03336CH): Replace the Aerostar International Basket/Burner system with the Cameron Balloons Basket, Part Number CB301C-4, S/N 9465; the Cameron Balloons Burner, Part Number CB579-M1, S/N S5148  S5149.  Replace the Aerostar International fuel tanks with the Cameron Balloons Fuel Tanks, Part Number CBUS1050D, S/Ns 230171, 230177, and 230202.. Nathan W. Dieringer
- [STC SB03337CH](https://openairdocs.org/stc/SB03337CH): Replace the Aerostar International Basket/Burner system with the Cameron Balloons Basket, Part Number CB301C-4, S/N 9465; the Cameron Balloons Burner, Part Number CB579-M1, S/N S5148  S5149.  Replace the Aerostar International fuel tanks with the Cameron Balloons Fuel Tanks, Part Number CBUS1050D, S/Ns 230171, 230177, and 230202.. Nathan W. Dieringer
- [STC SB03299CH](https://openairdocs.org/stc/SB03299CH): Replace the Aerostar International Basket/Burner system with the Balony Kubicek Basket Model K13S, S/N 408 and the Balony Kubicek Burner Model IGNIS 2 Units, S/N 749 and 750. Michael Bauwens
- [STC SB03216CH](https://openairdocs.org/stc/SB03216CH): Replace the Aerostar International Basket/Burner system and fuel tanks. Brad Craig
- [STC SB02986CH](https://openairdocs.org/stc/SB02986CH): Replace the Aerostar International Basket with the Ultramagic Basket Model C-9, S/N 27, by replacing the Aerostar International load blocks with Ultramagic carabiners.. Black Hills Balloons Inc.
- [STC SB02820CH](https://openairdocs.org/stc/SB02820CH): ONE ONLY STC, SN 3007: Replace Aerostar International Basket/Burner system and fuel tanks.. John T. Moran dba Falcon's Nest Repair Station
- [STC SB02299CH](https://openairdocs.org/stc/SB02299CH): ONE - ONLY S/N S57A-3159 Replace the existing Aerostar International Basket, Burner, and fuel tanks. Chuck L. Walz
- [STC SB01670NY](https://openairdocs.org/stc/SB01670NY): Installation of Aerostat Envelopes, Inc. model W-210-4 lifting envelope.. DiGiovanni Ronald T.
- [STC SB02148CH](https://openairdocs.org/stc/SB02148CH): Descriptive data pertaining to this design change are considered inadequate for duplication in other products.  This approval is limited to only the installation made in Aerostar International Model QUBE-80, Serial No. QUBE-80-3003. Replace the existing Aerostar International Basket, Burner, and fuel tanks with the Lindstrand Balloons Basket, Part Number BA-006-A-001, S/N 1049; Lindstrand Balloons Burner, Part Number BU-007-A-001, S/N BU934; and Lindstrand Balloons fuel tanks, Part Number CY-030-A-001, S/Ns 1021, 1063, and 1064.. Caton Roy
- [STC SB917GL](https://openairdocs.org/stc/SB917GL): Addition of a refueling adapter to the main fuel line.. LTA Aviation Inc
- [STC SB00096NY](https://openairdocs.org/stc/SB00096NY): Installation of Aerostat Envelopes Model W-175-4 replacement envelope.. DiGiovanni Ronald T.
- [STC SB00601NY](https://openairdocs.org/stc/SB00601NY): Installation of Aerostat Envelopes model W-100-4 replacement envelope.. DiGiovanni Ronald T.
- [STC SB705NE](https://openairdocs.org/stc/SB705NE): Installation of an Aerostat envelope, Model W-140-2.. Ronald T. DiGiovanni
- [STC SB735NE](https://openairdocs.org/stc/SB735NE): Installation of an Aerostat envelope, Model W-140-4.. Ronald T. DiGiovanni
- [STC SB736NE](https://openairdocs.org/stc/SB736NE): Installation of an Aerostat envelope Model W-140-4.. Ronald T. DiGiovanni
- [STC SB737NE](https://openairdocs.org/stc/SB737NE): Installation of an Aerostat envelope Model W-140-2 and W-140-4.. Ronald T. DiGiovanni
- [STC SB742NE](https://openairdocs.org/stc/SB742NE): Installation of an Aerostat envelope, model W-140-2 (2-point system) and W-140-4 (point system).. Ronald T. DiGiovanni
- [STC SB00794LA](https://openairdocs.org/stc/SB00794LA): Installation of extra fuel tank(s).. John Terry
- [STC SB00713LA](https://openairdocs.org/stc/SB00713LA): Installation of one additional 10 gallon propane tank.. John Terry
- [STC SA2738SW](https://openairdocs.org/stc/SA2738SW): Installation of an electric operated valve.. John Terry
- [STC SB00407LA](https://openairdocs.org/stc/SB00407LA): Installation of foam padded tank covers.. John Terry
- [STC SA5469NM](https://openairdocs.org/stc/SA5469NM): Installation of position light.. Great American Balloon Co Inc
- [STC SA2737SW](https://openairdocs.org/stc/SA2737SW): Removal of LPG regulator.. AERCO
- [STC SA2758SW](https://openairdocs.org/stc/SA2758SW): Installation of revised deflation valve.. AERCO
- [STC SL1572SO](https://openairdocs.org/stc/SL1572SO): Replacement of envelope fabric.. Head Balloons Inc
- [STC SB2299NM](https://openairdocs.org/stc/SB2299NM): Installation of position lights.. Kelly Nancy K
- [STC SL211RM](https://openairdocs.org/stc/SL211RM): Modification of suspension system and skirt of Raven S-55A hot air balloon envelope to achieve compatibility with Barnes Balloon Works gondola Models 4.0 and 4.5 and Model T3-017 burner system.. Raven Industries, Inc
- [STC SL163GL](https://openairdocs.org/stc/SL163GL): Modification: Move the velcro 4 to6 inches back away from the lip of the deflation port. Enlarge deflation panel.. Wiederkehr Matt H

All 58: https://openairdocs.org/tcds/A15CE/stcs.md

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.